15
SYSTEM DESCRIPTION APPROVED BY DRG REF: DATE SCALE PAPER SIZE REVISION SHEET This document remains the property of Kingspan Ltd under copyright laws. Licence is granted to use this document and its contents in connection with Kingspan Ltd products only. ©Kingspan Ltd DO NOT SCALE. IF IN DOUBT ASK New Zealand: Kingspan Ltd 97 Montreal St Christchurch Tel: +64 (3) 260 5530 Fax: +64 (3) 260 5539 Freephone: 0800 121280 email: [email protected] www.kingspanpanels.co.nz APPR A4 1 OF 1 1:5 LP_RS_00 1 11.02.16 DRAWING LIST KS1000 LP ROOF_STD Q1 2016.DWG KS1000 LP/CR (Lo-Pitch / Curved Roof) ROOF PANEL (Q1 2016) DATE DRG TITLE DRG_REF REVISION 11.02.16 DRAWING LIST LP_RS_00 1 11.02.16 KS1000 LP PROFILE LP_RS_01 1 11.02.16 KS1000 LP SIDE JOIN & COVER CAP FIXING LOCATIONS LP_RS_02 1 11.02.16 KS1000 LP SIDE JOIN & COVER CAP FIXING LOCATIONS (HIGH HUMIDITY) LP_RS_03 1 11.02.16 KS1000 LP END LAP FIXING LOCATIONS LP_RS_04 1 11.02.16 KS1000 LP APEX DAM LP_RS_05 1 11.02.16 KS1000 LP RIDGE DETAIL LP_RS_06 1 11.02.16 KS1000 LP END LAP DETAIL LP_RS_07 1 11.02.16 KS1000 LP EAVES DETAIL LP_RS_08 1 11.02.16 KS1000 LP INTERNAL GUTTER DETAIL LP_RS_09 1 11.02.16 KS1000 LP VALLEY GUTTER LP_RS_10 1 11.02.16 KS1000 LP VERGE DETAIL LP_RS_11 1 11.02.16 KS1000 LP VERGE PARAPET LP_RS_12 1 11.02.16 KS1000 CR CURVED ROOF SETOUT CR_RS_01 1 11.02.16 KS1000 CR END LAP DETAIL CR_RS_02 1 DRAWING LIST G:\Technical\1-current\Drawings\current 2013 Q1\Lo_pitch Roof\KS1000 LP ROOF_Std Q1 2016.dwg, LP_RS_00, 8/12/2016 12:39:47 p.m.

KS1000 LP/CR (Lo-Pitch / Curved Roof) ROOF PANEL (Q1 · PDF filemin 2x fixings per crown. 75mm end lap 10 max 25 15 kingspan ks1000 cr (curved roof) roof panel minimum 300mm between

  • Upload
    lylien

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:5LP_RS_00

111.02.16

DRAWING LIST

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP/CR (Lo-Pitch / Curved Roof) ROOF PANEL (Q1 2016)

DATE DRG TITLE

DRG_REF

REVISION

11.02.16 DRAWING LIST LP_RS_00 1

11.02.16 KS1000 LP PROFILE LP_RS_01 1

11.02.16 KS1000 LP SIDE JOIN & COVER CAP FIXING LOCATIONS LP_RS_02 1

11.02.16 KS1000 LP SIDE JOIN & COVER CAP FIXING LOCATIONS

(HIGH HUMIDITY)

LP_RS_03 1

11.02.16 KS1000 LP END LAP FIXING LOCATIONS LP_RS_04 1

11.02.16 KS1000 LP APEX DAM LP_RS_05 1

11.02.16 KS1000 LP RIDGE DETAIL LP_RS_06 1

11.02.16 KS1000 LP END LAP DETAIL LP_RS_07 1

11.02.16 KS1000 LP EAVES DETAIL LP_RS_08 1

11.02.16 KS1000 LP INTERNAL GUTTER DETAIL LP_RS_09 1

11.02.16 KS1000 LP VALLEY GUTTER LP_RS_10 1

11.02.16 KS1000 LP VERGE DETAIL LP_RS_11 1

11.02.16 KS1000 LP VERGE PARAPET LP_RS_12 1

11.02.16 KS1000 CR CURVED ROOF SETOUT CR_RS_01 1

11.02.16 KS1000 CR END LAP DETAIL CR_RS_02 1

DRAWING LIST

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_00, 8/12/2016 12:39:47 p.m

.

37525152625262525262526252515237 51

NOTE: ABOVE DIMENSIONS ARE THEORETICAL, ACTUAL DIMENSIONS WILL VARY DUE TO

MANUFACTURING TOLERANCES. PRECISE DIMENSIONS MUST ALWAYS BE MEASURED

FROM ACTUAL SAMPLES. ALL DIMENSIONS IN MILLIMETRES.

INSULATION

CORE (A)

OVERALL PANEL

THICKNESS (B)

45

60

80

100

75

90

110

130

1000 COVER WIDTH

AVAILABLE PANEL THICKNESSES

A

B

3

1.5

IN

SU

LA

TIO

N

CO

RE

33.3 33.3

30

7

37

INTERNAL LINER SHEET

EXTERNAL WEATHER SHEET

ANTI CONDENSATION TAPE

(FACTORY APPLIED)

FASTENER

LOCATION

1.5

33.3 33.3

56°

3mm RADIUS

FASTENER

LOCATION

17

ANTI CONDENSATION TAPE

(FACTORY APPLIED)

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 of 11:5LP_RS_01

111.02.16

KS1000 LP ROOF PANEL DIMENSIONS

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP ROOF PANEL DIMENSIONS

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_01, 8/12/2016 12:39:51 p.m

.

KINGSPAN KS1000 LP LO-PITCH

ROOF PANEL

KINGSPAN KS1000 LP LO-PITCH

COVER CAP WITH FOAM SEALING

STRIP (FACTORY APPLIED)

FOAM SEALING STRIP (FACTORY APPLIED)

PURLIN

MAIN FIXINGS

COVER CAP STITCHING SCREWS OR

SEALED RIVETS AT EAVES AND END LAPS

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:5LP_RS_02

111.02.16

KS1000 LP SIDE JOIN & COVER CAP

FIXING LOCATIONS

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP SIDE JOIN & COVER CAP FIXING LOCATIONS

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_02, 8/12/2016 12:39:52 p.m

.

KINGSPAN KS1000 LP LO-PITCH ROOF PANEL

KINGSPAN KS1000 LP LO-PITCH COVER CAP

WITH FOAM SEALING STRIP (FACTORY APPLIED)

FOAM SEALING STRIP (FACTORY APPLIED)

6mm GUN GRADE SILICONE SEALANT (SITE APPLIED)

TWO CONTINUOUS RUNS OF 6X4 BUTYL SEALING

TAPE. ONE EITHER SIDE OF FIXING TO PREVENT

INGRESS OF MOIST AIR

TWO RUNS OF 6X4 BUTYL SEALING TAPE TO ACROSS

PURLIN PREVENT INGRESS OF MOIST AIR TO FIXING

TIMBER PURLIN

(TYPICAL)

STAINLESS STEEL FIXINGS

COVER CAP STITCHING SCREWS OR

SEALED RIVETS AT EAVES AND END LAPS

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:5LP_RS_03

111.02.16

KS1000 LP SIDE JOIN & COVER CAP FIXING

LOCATIONS (HIGH HUMIDITY)

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP SIDE JOIN & COVER CAP FIXING LOCATIONS

(HIGH HUMIDITY)

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_03, 8/12/2016 12:39:52 p.m

.

FILL GAPS WITH CANISTER FR FOAM FILLER

MP FOAM LP RIDGE FILLER SEALED TOP & BOTTOM

WITH NON-SETTING GUN GRADE SEALANT

0.5MM COIL COATED RIDGE FLASHING WITH

150mm SEALED OVERLAP OR BUTT-STRAPS

CONTINUOUS RUN 6x4 BUTYL SEALANT

COVER CAP

0.5MM COIL COATED INTERNAL RIDGE FLASHING

WITH 150mm SEALED OVERLAP OR BUTT-STRAPS

ALTERNATIVE RIDGE CAP

TURN UP PANEL ENDS.

KINGSPAN KS1000 LP ROOF PANEL

BEAD OF NON SETTING GUN GRADE SEALANT.

SCREW FIX RIDGE FLASHING AT 300mm CTRS

APEX DAM (REF LP_1)

2 RUNS OF NON SETTING GUN GRADE

SEALANT. SCREW FIX IN

PRE-PUNCHED HOLES

BEAD OF NON SETTING

GUN GRADE SEALANT

RIDGE FILLER (REF LP1/F1)

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:5LP_RS_04

111.02.16

KS1000 LP RIDGE DETAIL

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP RIDGE DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_04, 8/12/2016 12:39:53 p.m

.

END LAP - FASTENER LOCATIONS (LO-PITCH KS1000 LP)

END LAP - FASTENER LOCATIONS (CURVED ROOF KS1000 CR)

PROFILED FILLER AT RIDGE

TAIL STITCHING PLATE ON

LOWER PANEL

FIX TAIL STITCHING SCREWS FROM THE

CENTRE OUT (MIN 38mm FIXINGS)

123 2 3

TAIL STITCHING PLATE ON

LOWER PANEL

PANEL JOIN

TAIL STITCHING SCREW KS1000 LP

PRIMARY FIXING

LOWER PANEL

UPPER PANEL

KS1000 LP

123 2 3

TAIL STITCHING PLATE

ON LOWER PANEL

PANEL JOIN

TAIL STITCHING SCREWS KS1000 CR

PRIMARY FIXING

LOWER PANEL

UPPER PANEL

KS1000 CR

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:5LP_RS_05

111.02.16

KS1000 LP END LAP FIXING

LOCATIONS

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP END LAP FIXING LOCATIONS

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_05, 8/12/2016 12:39:54 p.m

.

MP FOAM RIDGE FILLER SEALED TOP & BOTTOM

WITH BEAD OF NON-SETTING GUN GRADE SEALANT

2X6mm RUNS NON-SETTING GUN

GRADE SEALANT TO FOLLOW PROFILE

FOLDED STEEL RIDGE DAM

(FROM BELOW)

FOLDED STEEL RIDGE DAM

(FROM ABOVE)

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:1LP_RS_06

111.02.16

KS1000 LP APEX DAM

KS1000 LP ROOF_STD Q1 2016.DWG

CONTINUOUS 10mm RUN

NON-SETTING GUN GRADE BUTYL

SEALANT

10mm RUN NON-SETTING GUN GRADE

SEALANT TO TOP & BOTTOM OF FOAM

FILLER TO FOLLOW PROFILE

KS1000 LP APEX DAM

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_06, 8/12/2016 12:39:54 p.m

.

MIN 2X FIXINGS PER CROWN.

75MM

EN

D LA

P

10 MA

X

25

15

KINGSPAN KS1000 CR (CURVED

ROOF) ROOF PANEL

MIN

IMU

M 300m

m B

ET

WE

EN

PA

NE

L EN

D LA

P A

ND

CO

VE

R C

AP

JOIN

T

COVER CAP COMPLETE WITH

JOGGLE END. FACTORY

APPLIED

CONTINUOUS RUN OF

SILICONE SEALANT

COVER CAP STITCH SCREWED TO LP

PANEL 100mm EITHER SIDE OF LAP JOIN

COVER CAP (STD TO RIDGE)

75mm

JOG

GLE

2 RUNS OF SIKAFLEX SNB MASTIC TO SIDE JOINT

CONTINUOUS BEAD OF SIKAFLEX SNB MASTIC

30MM

MIN

20MM

MIN

FACTORY FITTED END LAP

STITCHING PLATE

18x4mm U SECTION BUTYL RUBBER SEALANT

KS1000 LP (LO-PITCH) PANEL LAP DETAIL.

MIN SLOPE 1.5° AT LAP

END LAP STITCHING SCREW

END LAP - FASTENER LOCATIONS (LO-PITCH KS1000 LP)

TAIL STITCHING PLATE ON

LOWER PANEL

123 2 3

KINGSPAN KS1000 LP/CR COVER

CAP WITH FOAM SEALING STRIP

(FACTORY APPLIED)

PURLIN

MAIN FIXINGS

COVER CAP STITCHING SCREWS

OR SEALED RIVETS AT EAVES

AND COVER CAP END LAPS

2 RUNS OF OF NON-SETTING GUN

GRADE SEALANT TO SIDE JOINT

AT END LAPS

KINGSPAN KS1000 LP

LO-PITCH ROOF PANEL

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:3LP_RS_07

111.02.16

KS1000 LP END LAP DETAIL

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP END LAP DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_07, 8/12/2016 12:39:55 p.m

.

FILL GAPS WITH FR FOAM FILLER

SITE APPLIED NON-SETTING GUN GRADE EAVES SEAL

75mm EAVES OVERHANG. TURN DOWN PAN AT EAVES

KINGSPAN KS1000 AWP

PANEL HORIZONTALLY LAID

GUTTER BRACKET ATTACHED TO

FASCIA BOARD FIXED TO EAVES

PURLIN.

PRESSED STEEL GUTTER

INTERNAL FLASHING SEALED WITH 6x4

BUTYL SEALANT. LAP AND SEAL JOINS

TO MAINTAIN CONTINUITY OF SEALANT

KINGSPAN KS1000 LP ROOF

PANEL

COVER CAP STITCH SCREWED TO LP

PANEL 100mm UP FROM EAVES

CUT PANEL. FIXINGS AT 1.0M CTRS

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:5LP_RS_08

111.02.16

KS1000 LP EAVES DETAIL

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP EAVES DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_08, 8/12/2016 12:39:56 p.m

.

SITE APPLIED SILICONE EAVES SEAL

FIXING AT CROWN

0.5mm COIL COATED EDGE FLASHING

SEALED WITH 6x4 BUTYL SEALANT

0.5mm COIL COATED

CORNER FLASHING SEALED

WITH 6x4 BUTYL SEALANT

75x125mm X 0.5mm COIL COATED STEEL

TRIM. STAGGER RIVETS AT 200 CTRS.

SEALED WITH 6x4 BUTYL SEALANT

0.9mm GALV. CONTINUOUS STEEL

BRACKET FIXED TO BACK OF GUTTER

WITH 3 NO. 4mm RIVETS @200CRS

ALONG GUTTER

0.5MM COIL COATED EDGE

FLASHING SEALED WITH 6x4

BUTYL SEALANT

INSULATED GUTTER SITE

BUILT BY CONTRACTOR

AIR SEAL 6x4 BUTYL SEALANT

0.9mm GALV. CONTINUOUS STEEL

BRACKET FIXED TO BACK OF GUTTER

WITH 3 NO. 4mm RIVETS @200CRS

ALONG GUTTER

BUTYNOL GUTTER LINING

KS1000 RW PARAPET PANEL

75

GUTTER HIGH POINT

0.5MM COIL COATED CUT

EDGE PROTECTION

FLASHING (IF REQUIRED)

50

75mm EAVES OVERHANG. TURN DOWN PAN AT EAVES

COVER CAP STITCH SCREWED TO LP

PANEL 100mm UP FROM EAVES

AIR SEAL 6x4

BUTYL SEALANT

COVER CAP

5

° M

IN

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 of 11:5LP_RS_09

111.02.16

KS1000 LP INTERNAL GUTTER DETAIL

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP INTERNAL GUTTER DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_09, 8/12/2016 12:39:56 p.m

.

SITE APPLIED NON-SETTING

GUN GRADE EAVES SEAL

FIXING AT CROWN

0.5mm COIL COATED

CORNER FLASHING SEALED

WITH 6x4 BUTYL SEALANT

75x125mm X 0.5mm COIL COATED STEEL

TRIM. STAGGER RIVETS AT 200 CTRS.

SEALED WITH 6x4 BUTYL SEALANT

0.9mm GALV. CONTINUOUS STEEL

BRACKET FIXED TO BACK OF GUTTER

WITH 3 NO. 4mm RIVETS @200CRS

ALONG GUTTER

0.5mm COIL COATED EDGE

FLASHING SEALED WITH 6x4

BUTYL SEALANT

MIN 50mm THICK INSULATED GUTTER

SITE BUILT BY CONTRACTOR

AIR SEAL 6x4 BUTYL SEALANT

BUTYNOL GUTTER LINING

75

GUTTER HIGH POINT

75

SITE CUT-BACK (RAKED)

75mm EAVES OVERHANG.

TURN DOWN PAN AT EAVES

COVER CAP STITCH SCREWED TO

LP PANEL 100mm UP FROM EAVES

COVER

CAP

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:5LP_RS_10

111.02.16

KS1000 LP VALLEY GUTTER

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP VALLEY GUTTER

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_10, 8/12/2016 12:39:57 p.m

.

"Z" FLASHING WITH CONTINUOUS RUNS

OF 20x3mm BUTYL SEALANT

0.5mm COIL COATED VERGE FLASHING WITH 150mm

SEALED OVERLAP OR BUTT-STRAPS. SEALED TO

WALL PANEL WITH 6x4 BUTYL SEALANT

DIRECTION

OF LAY

FILL GAPS WITH FR FOAM FILLER

KS1000 LP/CR INSULATED

ROOF PANEL

KS1000 LP ROOF VERGE DETAIL

(FACTORY EDGE)

GALV CLEADER ANGLE BY STEEL CONTRACTOR. AIR

SEAL WITH 6x4mm BUTYL SEALANT. BUTT STRAPS

AT JOINS TO MAINTAIN CONTINUITY OF SEALANT

"Z" FLASHING WITH CONTINUOUS RUNS OF

20x3mm BUTYL SEALANT

0.5mm COIL COATED VERGE FLASHING WITH 150mm

SEALED OVERLAP OR BUTT-STRAPS. SEALED TO

WALL PANEL WITH 6x4 BUTYL SEALANT

DIRECTION

OF LAY

FILL GAPS WITH FR FOAM FILLER

KS1000 LP/CR INSULATED ROOF

PANEL

KS1000 LP ROOF VERGE DETAIL

(SITE CUT)

GALV CLEADER ANGLE BY STEEL CONTRACTOR. AIR

SEAL WITH 6x4mm BUTYL SEALANT. BUTT STRAPS AT

JOINS TO MAINTAIN CONTINUITY OF SEALANT

TURN UP SITE CUT EDGE OF PANEL 30mm

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:5LP_RS_11

111.02.16

KS1000 LP VERGE DETAIL

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP VERGE DETAIL

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_11, 8/12/2016 12:39:57 p.m

.

KINGSPAN KS1000 LP

ROOFING PANEL

CONTINUOUS RUN OF 6x4 BUTYL SEALANT. LAP

FLASHINGS TO MAINTAIN CONTINUITY OF AIR SEAL

INTERNAL CLOSER FLASHING

"Z" FLASHING WITH CONTINUOUS RUNS

OF 20x3mm BUTYL SEALANT

FILL GAPS WITH FR FOAM FILLER

0.5mm COIL COATED PARAPET

FLASHING SEALED WITH CONTINUOUS

RUN OF 6x4mm BUTYL SEALANT

INFILL

BLOCK

CUT PANEL - FIXINGS

AT 1.0m CTRS

AWP PANEL BEARER

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:5LP_RS_12

111.02.16

KS1000 LP VERGE PARAPET

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 LP VERGE PARAPET

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, LP

_R

S_12, 8/12/2016 12:39:58 p.m

.

BUILDING WIDTH BETWEEN 70 & 100M TYPICAL

LAP ANGLE MIN 1.5° AFTER DEFLECTIONS

PANEL 1

(EAVES)

PANEL 2

(CROWN)

PANEL 3

(EAVES)

KS1000 CR - CURVED ROOF PANEL LAYOUT SEQUENCE

PURLIN SPACING 1800MM MAX

CURVED ROOF: MIN 150M RADIUS

END LAP - FASTENER LOCATIONS (CURVED ROOF KS1000 CR)

FIX TAIL STITCHING SCREWS FROM THE

CENTRE OUT (MIN 38mm FIXINGS)

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 1NTSCR_RS_01

111.02.16

KS1000 CR CURVED ROOF SETOUT

KS1000 LP ROOF_STD Q1 2016.DWG

KS1000 CR CURVED ROOF SETOUT

G:\T

echnical\1-current\D

raw

ings\current 2013 Q

1\Lo_pitch R

oof\K

S1000 LP

R

OO

F_S

td Q

1 2016.dw

g, C

R_R

S_01, 8/12/2016 12:39:59 p.m

.

MIN 2X FIXINGS PER CROWN.

75MM

EN

D LA

P

10 MA

X

25

15

END LAP STITCHING SCREW

FACTORY FITTED END LAP STITCHING PLATE

18x4mm U SECTION BUTYL RUBBER SEALANT

KINGSPAN KS1000 CR (CURVED

ROOF) ROOF PANEL

MIN

IMU

M 300m

m B

ET

WE

EN

PA

NE

L EN

D LA

P A

ND

CO

VE

R C

AP

JOIN

T

COVER CAP COMPLETE WITH

JOGGLE END. FACTORY

APPLIED

CONTINUOUS RUN OF

SILICONE SEALANT

COVER CAP STITCH SCREWED TO LP

PANEL 100mm EITHER SIDE OF LAP JOIN

COVER CAP (STD TO RIDGE)

75mm

JOG

GLE

75MM

2 RUNS OF NON-SETTING GUN GRADE SEALANT

TO SIDE JOINT

CONTINUOUS BEAD OF SIKAFLEX SNB MASTIC

75MM

1.5mm GALV CURVED ROOF

SUPPORT CLOSURE PLATE (LP2)

END LAP - FASTENER LOCATIONS (CURVED ROOF KS1000 CR)

FIX TAIL STITCHING SCREWS FROM THE

CENTRE OUT (MIN 38mm FIXINGS)

KINGSPAN KS1000 LP/CR COVER

CAP WITH FOAM SEALING STRIP

(FACTORY APPLIED)

PURLIN

MAIN FIXINGS

COVER CAP STITCHING SCREWS

OR SEALED RIVETS AT EAVES

AND COVER CAP END LAPS

2 RUNS OF OF NON-SETTING GUN

GRADE SEALANT TO SIDE JOINT

AT END LAPS

KINGSPAN KS1000 LP

LO-PITCH ROOF PANEL

SYSTEM

DESCRIPTION

APPROVED BY

DRG REF:

DATE

SCALE PAPER SIZE

REVISION

SHEET

This document remains the property of Kingspan Ltd under

copyright laws. Licence is granted to use this document and

its contents in connection with Kingspan Ltd products only.

©Kingspan Ltd

DO NOT SCALE. IF IN DOUBT ASK

New Zealand: Kingspan Ltd

97 Montreal St

Christchurch

Tel: +64 (3) 260 5530

Fax: +64 (3) 260 5539

Freephone: 0800 121280

email: [email protected]

www.kingspanpanels.co.nz

APPR

A41 OF 11:3CR_RS_02

111.02.16

KS1000 CR (CURVED ROOF) PANEL