This Addendum includes a number of data set updates which supersede the information in the 2013 Complete Drywall Manual from Knauf. Full test data is available on request. Contents

An introduction to Knauf Drywall Systems

Knauf Performer ‘C’ Stud Partition

Knauf Performer ‘I’ Stud Partition

Knauf Performer Partition with Knauf Resilient Bar

Knauf Isolator (Twin Frame) Partition

Knauf Silent Spacesaver (Staggered Stud) Partition

Knauf Shaftwall

Knauf ‘I’ Stud Linings (Free Standing)

Knauf AQUAPANEL® Interior System

Knauf MF Suspended Ceiling Membranes

Build for the world we live in

05

060810

1214

16182224

26

Page 3: Knauf Drywall Systems

5

Drywall systems that meet all your application and construction needs. Innovation, ease of use and integration go together to provide powerful, high performance and simple-to-implement solutions across all building sectors.

An introduction to Knauf Drywall Systems

Knauf Performer

The Knauf Performer system is our most versatile and commonly used partition system. It is constructed using a single row of Knauf metal studs with Knauf plasterboards to both sides in order to meet fire, acoustic, moisture and impact requirements. The Performer system is lightweight, simple to construct and should be used in conjunction with Knauf’s finishing solutions range.

Knauf Performer with Knauf Resilient Bar

Knauf Resilient Bar can be added to both or one side of certain Knauf Performer systems. This additional component improves the acoustic sound reduction performance of the system in order to meet higher acoustic requirements

Knauf Isolator (Twin Frame)

The Knauf Isolator system is typically used to divide habitable dwellings. The twin stud build up, combined with Knauf’s high performance plasterboards, maximises acoustic performance in order to comply with building regulations, technical handbooks and guidances for sound insulation.

Knauf Silent Spacesaver (Staggered Stud)

The Knauf Silent Spacesaver system provides a high acoustic performance partition from a narrow footprint. Using a single row of Knauf Staggered ‘I’ Studs and clips, rather than a twin row of parallel metal studs, the Silent Spacesaver can optimise the available space within the building whilst still achieving up to 60dB (Rw) sound reduction.

Knauf Shaftwall

Knauf Shaftwall is our innovative system to form enclosures around service and lift shafts while working from one side. The unique Knauf ‘C-T’ Stud makes this possible with a minimum of components. The system can provide a high level of fire resistance performance to meet the requirements of your project.

Knauf ‘I’ Stud Linings (Free Standing)

Knauf Independent ‘I’ Stud is a fully independent wall lining system that can be used in all building types to upgrade the acoustic, fire and thermal performance of an existing masonry wall and to deal with any irregularities. Due do the system using an Knauf ‘I’ Stud, there is no requirement for the lining system to be fixed back into the structure behind.

Knauf AQUAPANEL® Cement Board Indoor Board / Interior System

Knauf AQUAPANEL® Cement Board Indoor is exceptionally tough and durable, providing a solid tile backing substrate for wet indoor areas such as swimming pools, leisure centres, bathrooms and kitchens. The board is used in conjunction with specialist screws and finishing products to provide a full Knauf solution for humid and wet conditions.

Knauf Metal Furring (MF) Suspended Ceiling System

The Knauf Metal Furring (MF) Suspended Ceiling system is versatile and easy to install. Deep voids are easily created to hide services and the ceiling can be used to provide fire protection to the soffit above. The Knauf MF Suspended Ceiling system is very familiar to contractors who will easily be able to form openings, bulkheads and coffers.

Page 4: Knauf Drywall Systems

6 7

Dimensions (mm) Maximum height (mm)1 Acoustic sound reduction (dB Rw)2 Fire resistance period3

Stud depthand gauge

Overallwidth

(excluding finishes)

Plasterboard thickness

Number of layers

‘C’ Stud centres (mm) Wallboard2 Soundshield Plus/ Performance Plus

BS 476: Part 221 EN 1364-1

600 400 300 No Insulation

With Insulation

25mmAPR*

No Insulation

With Insulation2

25mmAPR*

Wallboard1 Soundshield Plus

Fire Panel/ Performance

Plus

Wallboard Soundshield Plus

Fire Panel/ Performance

Plus

50mm ‘C’ (0.55) 77 12.5 1 3000 3200 3400 34 42 37 43 30 30 30 – 30 3082 15 1 3100 3300 3500 35 42 38 45 30 60 60 30 60 60102 12.5 2 3700 3800 4000 41 48 44 50 60 60 120 60 60 120112 15 2 3900 4000 4200 43 49 45 51 90 120 120 60 120 120

60mm ‘C’ (0.55) 87 12.5 1 3400 3700 3900 34 42 37 43 30 30 30 – 30 3092 15 1 3600 3800 4000 35 42 38 45 30 60 60 30 60 60112 12.5 2 4300 4500 4600 41 48 44 50 60 60 120 60 60 120122 15 2 4500 4700 4800 43 49 45 51 90 120 120 60 120 120

70mm (0.55) 97 12.5 1 3600 3900 4200 36 42 39 43 30 30 30 – 30 30102 15 1 4000 4300 4500 38 43 40 45 30 60 60 30 60 60122 12.5 2 4500 4700 4900 43 48 47 53 60 60 120 60 60 120132 15 2 4800 5000 5200 44 49 48 53 90 120 120 60 120 120

70mm Acoustic ‘C’(0.60)

97 12.5 1 3800 4200 4500 – – – – 30 30 30 – 30 30102 15 1 4000 4400 4700 40 – 43 50** 30 60 60 30 60 60122 12.5 2 4800 5100 5300 – – – – 60 60 120 60 60 120132 15 2 5100 5300 5500 – – – 54 90 120 120 60 120 120

92mm ‘C’ (0.70) 119 12.5 1 4900 5300 5600 36 42 40 45 30 30 30 – 30 30124 15 1 5100 5400 5800 39 44 42 46 30 60 60 30 60 60144 12.5 2 5700 6100 6300 46 49 49 53 60 60 120 60 60 120154 15 2 6000 6300 6600 48 52 51 54 90 120 120 60 120 120

146mm ‘C’ (0.55) 173 12.5 1 5800 6400 7000 38 43 42 46 30 30 30 – 30 30178 15 1 6100 6700 7200 40 44 44 47 30 60 60 30 60 60198 12.5 2 7100 7500 7900 49 53 51 53 60 60 120 60 60 120208 15 2 7500 7900 8300 50 53 52 54 90 120 120 60 120 120

Knauf Performer ‘C’ Stud Partition

Performance tablesFor more information on these and other system performances, please contact the Technical Services webchat at www.knauf.co.uk or email [email protected].

1 Maximum heights and fire resistance: Maximum heights – calculated based on a limiting deflection of L/240 at 200 Pascals (0.2kN/m2). The maximum heights related above is for fire resistance of system to meet project requirements of BS 476: Part 22: 1987 only. For maximum heights in relation to meeting project requirements of BS EN 1364-1:2015, please consult Technical Services. The fire resistance rating for system using Knauf Wallboard in this column can also support fire resistance rating of system when replaced with Knauf Moisture Panel.

2 Acoustic sound reduction dB (Rw) Systems tested or assessed in accordance with BS EN ISO 10140-1:2010+A2:2014. Acoustic sound reduction based on ‘C’ Stud centres at 600mm centres. The acoustic sound reduction rating for Knauf Wallboard in this column can also support Knauf Fire Panel and Knauf Moisture Panel.

3 Period in minutes: inclusive of Integrity & Insulation * Knauf Insulation Acoustic Roll ** 50mm Knauf Insulation Acoustic Roll is needed

Note: Systems for both fire resistance and sound insulation performances are for imperforate partitions, incorporating plasterboard with all outer joints taped and filled, in accordance with Knauf recommendations.

Page 5: Knauf Drywall Systems

8 9

Knauf Performer ‘I’ Stud Partition

Performance tablesFor more information on these and other system performances, please contact the Technical Services webchat at www.knauf.co.uk or email [email protected].

Dimensions (mm) Maximum height (mm)1 Fire resistance period2

Stud depthand gauge

Overallwidth

(excluding finishes)

Plasterboard thickness

Number of layers

‘I’ Stud centres (mm) BS 476: Part 221 EN 1364-1

600 400 300 Wallboard1 Soundshield Plus

Fire Panel/ Performance

Plus

Wallboard Soundshield Plus

Fire Panel/ Performance

Plus

50mm ‘I’ (0.55) 77 12.5 1 3400 3700 4000 30 30 30 – 30 3082 15 1 3500 3800 4000 30 60 60 30 60 60102 12.5 2 4000 4200 4400 60 60 120 60 60 120112 15 2 4200 4400 4600 90 120 120 60 120 120

60mm ‘I’ (0.55) 87 12.5 1 3800 4200 4500 30 30 30 – 30 3092 15 1 4000 4400 4700 30 60 60 30 60 60112 12.5 2 4600 4900 5100 60 60 120 60 60 120122 15 2 4800 5100 5300 90 120 120 60 120 120

70mm ‘I’ (0.70) 97 12.5 1 4400 4900 5300 30 30 30 – 30 30102 15 1 4700 5100 5500 30 60 60 30 60 60122 12.5 2 4900 5300 5600 60 60 120 60 60 120132 15 2 5300 5700 6000 90 120 120 60 120 120

92mm ‘I’ (0.90) 119 12.5 1 5900 6500 7000 30 30 30 – 30 30124 15 1 5900 6500 7100 30 60 60 30 60 60

144 12.5 2 6500 7000 7500 60 60 120 60 60 120154 15 2 6900 7400 7800 90 120 120 60 120 120

146mm ‘I’ (0.90) 173 12.5 1 7800 8000 9600 30 30 30 – 30 30178 15 1 7900 8900 9700 30 60 60 30 60 60198 12.5 2 8600 9400 10200 60 60 120 60 60 120208 15 2 8800 9700 10400 90 120 120 60 120 120

1 Maximum heights and fire resistance: Maximum heights – calculated based on a limiting deflection of L/240 at 200 Pascals (0.2kN/m2). The maximum heights related above is for fire resistance of system to meet project requirements of BS 476: Part 22: 1987 only. For maximum heights in relation to meeting project requirements of BS EN 1364-1:2015, please consult Technical Services. The fire resistance rating for system using Knauf Wallboard in this column can also support fire resistance rating of system when replaced with Knauf Moisture Panel.

2 Period in minutes: inclusive of Integrity & Insulation Note: Systems for fire resistance performances are for imperforate partitions, incorporating plasterboard with all outer joints taped and filled, in accordance with Knauf recommendations.

Page 6: Knauf Drywall Systems

10 11

Knauf Performer Partition with Knauf Resilient Bar

Performance tablesFor more information on these and other system performances, please contact the Technical Services webchat at www.knauf.co.uk or email [email protected].

Dimensions (mm) Maximum height (mm) with Stud

centres at 600mmcentres1

Acoustic sound reduction dB (Rw)2 Fire resistance period3

Stud depthand gauge

Knauf Resilient Bar

Overall width (excludingfinishes)

Plasterboard thickness Plasterboard type Number of

layers Insulation BS EN ISO 1040-2: 2010 BS 476: Part 221

70mm ‘C’ (0.55) Fixed to both sides at 600mm centres spanning horizontally

across stud frame164 15 Knauf Soundshield Plus 2 50mm APR* 3000 65 90

70mm ‘C’ (0.55)Fixed to one side at 600mm centres spanning across stud

frame148 15 Knauf Soundshield Plus 2 50mm APR* 4200 62 120

1 Maximum heights and fire resistance: Maximum heights – calculated based on a limiting deflection of L/240 at 200 Pascals (0.2kN/m2). The maximum heights related above is for fire resistance of system to meet project requirements of BS 476: Part 22: 1987 only. For maximum heights in relation to meeting project requirements of BS EN 1364-1:2015, please consult Technical Services.

2 Acoustic sound reduction dB (Rw) Systems tested or assessed in accordance with BS EN ISO 10140-1:2010+A2: 2014. Acoustic sound reduction based on ‘C’ Stud centres at 600mm centres.

3 Period in minutes: inclusive of Integrity & Insulation *Knauf Insulation Acoustic Roll

Note: Systems for both fire resistance and sound insulation performances are for imperforate partitions, incorporating plasterboard with all outer joints taped and filled, in accordance with Knauf recommendations.

Page 7: Knauf Drywall Systems

12 13

Knauf Isolator (Twin Frame) Partition

Performance tablesFor more information on these and other system performances, please contact the Technical Services webchat at www.knauf.co.uk or email [email protected].

Dimensions (mm) Maximum height (mm)1 Acoustic sound reduction (dB Rw)2 Fire resistance period3

Stud depthand gauge

Overall width (excludingfinishes)

Plasterboard thickness Plasterboard type Number of

layers InsulationUnbraced height at600mm

600mm centres

400mm centres

300mm centres BS EN ISO 1040-2: 2010 BS 476: Part 221

Twin 50mm ‘C’ (0.55) 185 15 Knauf Soundshield Plus 2 2 x 25mm APR* 2600 4550 6200 8700 64 120

Twin 70mm ‘C’ (0.55) 230 15 Knauf Soundshield Plus 2 2 x 25mm APR* 3000 7000 8000 9500 65 120

Twin 70mm ‘C’ (0.55) 240 12.5 Knauf Soundshield Plus 2 2 x Knauf Insulation Rocksilk®

RS60 50mm 3000 7000 8000 9500 66 60

Twin 92mm ‘C’ (0.70) 300 15 Knauf Soundshield Plus 2 1 x 100mm APR** 3000 8000 9000 9500 69 120Twin 92mm ‘C’ (0.70) 550 15 Knauf Soundshield Plus 3 1 x 100mm APR** 3000 8500 9500 10500 75 120Twin 92mm ‘C’ (0.70) 550 15 Knauf Soundshield Plus 3 2 x 100mm APR* 3000 8500 9500 10500 79 120

1 Maximum heights and fire resistance: Maximum heights – calculated based on a limiting deflection of L/240 at 200 Pascals (0.2kN/m2). The maximum heights related above is for fire resistance of system to meet project requirements of BS 476: Part 22: 1987 only. For maximum heights in relation to meeting project requirements of BS EN 1364-1:2015, please consult Technical Services.

2 Acoustic sound reduction dB (Rw) Systems tested or assessed in accordance with BS EN ISO 10140-1:2010+A2:2014. Acoustic sound reduction based on ‘C’ Stud centres at 600mm centres.

3 Period in minutes: inclusive of Integrity & Insulation

* Knauf Insulation Acoustic Roll in stud cavity** Knauf Insulation Acoustic Roll in central cavity= Bracing metal studs using Knauf Flat Fixing Plate or Knauf Fixing Channel at 1500mm. Note bracing using metal sections can

reduce the sound reduction insulation by approximately 2dB (Rw) to overall system.

= = =

Note: Systems for both fire resistance and sound insulation performances are for imperforate partitions, incorporating plasterboard with all outer joints taped and filled, in accordance with Knauf recommendations.

Page 8: Knauf Drywall Systems

14 15

Knauf Silent Spacesaver (Staggered Stud) Partition

Performance tablesFor more information on these and other system performances, please contact the Technical Services webchat at www.knauf.co.uk or email [email protected].

Dimensions (mm) Maximum height (mm) with Stud

centres at 600mmcentres1

Acoustic sound reduction (dB Rw)2 Fire resistance period3

Stud depthand gauge

Channel widthOverall width

(excludingfinishes)

Plasterboard thickness Plasterboard type Number of

layers Insulation BS EN ISO 1040-2: 2010 BS 476: Part 221

Staggered 60mm ‘I’ (0.55) 72 122 12.5 Knauf Soundshield Plus 2 50mm APR* 3300 57 60Staggered 60mm ‘I’ (0.55) 72 132 15 Knauf Soundshield Plus 2 50mm APR* 3300 60 90

Staggered 60mm ‘I’ (0.70) 72 122 12.5 Knauf Soundshield Plus 2 50mm APR* 3600 57 60Staggered 60mm ‘I’ (0.70) 72 132 15 Knauf Soundshield Plus 2 50mm APR* 3600 60 90

Staggered 92mm ‘I’ (0.90) 148 198 12.5 Knauf Soundshield Plus 2 50mm APR* 5300 58 60Staggered 92mm ‘I’ (0.90) 148 208 15 Knauf Soundshield Plus 2 25mm APR* 5300 59 90Staggered 92mm ‘I’ (0.90) 148 208 15 Knauf Soundshield Plus 2 50mm APR* 5300 60 90

1 Maximum heights and fire resistance: Maxiumum heights – calculated based on a limiting deflection of L/240 at 200 Pascals (0.2kN/m2). The maximum heights related above is for fire resistance of system to meet project requirements of BS 476: Part 22: 1987 only. For maximum heights in relation to meeting project requirements of BS EN 1364-1:2015, please consult Technical Services.

2 Acoustic sound reduction dB (Rw) Systems tested or assessed in accordance with BS EN ISO 10140-1:2010+A2:2014. Acoustic sound reduction based on ‘I’ Stud centres at 600mm centres (staggered 300mm).

3 Period in minutes: inclusive of Integrity & Insulation *Knauf Insulation Acoustic Roll

Note: Systems for both fire resistance and sound insulation performances are for imperforate partitions, incorporating plasterboard with all outer joints taped and filled, in accordance with Knauf recommendations.

Page 9: Knauf Drywall Systems

16 17

Knauf Shaftwall

Performance tablesFor more information on these and other system performances, please contact the Technical Services webchat at www.knauf.co.uk or email [email protected].

Dimensions (mm)Maximum height (mm) with Stud

centres at 600mmcentres1

Acoustic sound reduction (dB Rw)2

Fire resistance (Integrity:Insulation)

BS 476: Part 221

Fire resistance (Integrity:Insulation) BS 476: Part 221

Stud depthand gauge

Overall width (excludingfinishes)

Plasterboard specification (lobby/room side) Integral plasterboard to

shaft side

No Insulation With Insulation 25mm APR*

Fire exposure from lobby/room side & fire exposure

from shaft side

Fire exposure from lobby/room side

Fire exposure from shaft side

Plasterboard thickness

Plasterboard type **

Number of layers

60mm ‘C-T’ (0.92) 77 15 Knauf Fire Panel 1 19mm Knauf Core Board 4100 34 44 30:30 60:30 60:6060mm ‘C-T’ (0.92) 87 12.5 Knauf Fire Panel 2 19mm Knauf Core Board 4600 37 46 60:60 90:60 90:9060mm ‘C-T’ (0.92) 92 15 Knauf Fire Panel 2 19mm Knauf Core Board 4650 41 48 90:90 120:90 120:12060mm ‘C-T’ (0.92) 107 15 Knauf Fire Panel 3 19mm Knauf Core Board 4650 - 50 120:120 120:120 120:120

92mm ‘C-T’ (0.92) 109 15 Knauf Fire Panel 1 19mm Knauf Core Board 5800 40 45 30:30 60:30 60:6092mm ‘C-T’ (0.92) 119 12.5 Knauf Fire Panel 2 19mm Knauf Core Board 6500 42 46 60:60 90:60 90:9092mm ‘C-T’ (0.92) 124 15 Knauf Fire Panel 2 19mm Knauf Core Board 6700 43 48 90:90 120:90 120:12092mm ‘C-T’ (0.92) 139 15 Knauf Fire Panel 3 19mm Knauf Core Board 6700 - - 120:120 120:120 120:120

146mm ‘C-T’ (0.92) 163 15 Knauf Fire Panel 1 19mm Knauf Core Board 6900 41 46 30:30 60:30 60:60146mm ‘C-T’ (0.92) 173 12.5 Knauf Fire Panel 2 19mm Knauf Core Board 7700 45 52 60:60 90:60 90:90146mm ‘C-T’ (0.92) 178 15 Knauf Fire Panel 2 19mm Knauf Core Board 8300 45 52 90:90 120:90 120:120146mm ‘C-T’ (0.92) 193 15 Knauf Fire Panel 3 19mm Knauf Core Board 8300 - 54 120:120 120:120 120:120

1 Maximum heights and fire resistance: Maxiumum heights – calculated based on a limiting deflection of L/240 at 200 Pascals (0.2kN/m2). The maximum heights related above is for fire resistance of system to meet project requirements of BS 476: Part 22: 1987 only. For maximum heights in relation to meeting project requirements of BS EN 1364-1:2015, please consult Technical Services.

2 Acoustic sound reduction dB (Rw) Systems tested or assessed in accordance with BS EN ISO 10140-1:2010+A2: 2014. * Knauf Insulation Acoustic Roll ** Knauf Performance Plus is recommended as outer layer for areas requiring fire fighting lift shafts

Note: Systems for both fire resistance and sound insulation performances are for imperforate partitions, incorporating plasterboard with all outer joints taped and filled, in accordance with Knauf recommendations.

Page 10: Knauf Drywall Systems

18 19

Knauf ‘I’ Stud Linings (Free Standing fire resistance performance systems)

Performance tablesFor more information on these and other system performances, please contact the Technical Services webchat at www.knauf.co.uk or email [email protected].

Dimensions (mm) Maximum height (mm)1 Fire resistance (Integrity:Insulation)

Stud depthand gauge

Overall width(excluding finishes) Plasterboard thickness Number of layers Plasterboard

type‘I’ Stud centres (mm) BS 476: Part 221

600

50mm ‘I’ (0.55) 77 12.5 2 Knauf Wallboard 2900 30:3050mm ‘I’ (0.55) 67 15 1 Knauf Fire Panel 2900 30:1550mm ‘I’ (0.55) 82 15 2 Knauf Fire Panel 2900 60:4550mm ‘I’ (0.55) 97 15 3 Knauf Fire Panel 2900 120:9070mm ‘I’ (0.7) 97 12.5 2 Knauf Wallboard 3000 30:3070mm ‘I’ (0.7) 87 15 1 Knauf Fire Panel 3000 30:1570mm ‘I’ (0.7) 102 15 2 Knauf Fire Panel 3000 60:4570mm ‘I’ (0.7) 117 15 3 Knauf Fire Panel 3000 120:90

1 Maximum heights and fire resistance: Calculated based on a limiting deflection of L/240 at 200 Pascals (0.2kN/m2). The maximum heights related above is for fire resistance of system to meet project requirements of BS 476: Part 22: 1987 only. Please consult Technical Services for increased heights by emailing [email protected] or use the webchat.

Note: Systems for fire resistance performances are for imperforate partitions, incorporating plasterboard with all outer joints taped and filled, in accordance with Knauf recommendations.

Page 11: Knauf Drywall Systems

20 21

Knauf ‘I’ Stud Linings (Free Standing non-fire resistance performance systems)

Performance tablesFor more information on these and other system performances, please contact the Technical Services webchat at www.knauf.co.uk or email [email protected].

Dimensions (mm) Maximum height (mm)1

Stud depth and gaugePlasterboard

thickness Number of layers Plasterboard type‘I’ Stud centres (mm)

600 400 300

50mm ‘I’ (0.55) 12.5 1 Plasterboard to suit specification 2900 3300 360050mm ‘I’ (0.55) 12.5 2 Plasterboard to suit specification 2900 3300 360050mm ‘I’ (0.55) 15 1 Plasterboard to suit specification 2900 3300 360050mm ‘I’ (0.55) 15 2 Plasterboard to suit specification 2900 3300 3600

60mm ‘I’ (0.70) 12.5 1 Plasterboard to suit specification 3600 4100 450060mm ‘I’ (0.70) 12.5 2 Plasterboard to suit specification 3600 4100 450060mm ‘I’ (0.70) 15 1 Plasterboard to suit specification 3600 4100 450060mm ‘I’ (0.70) 15 2 Plasterboard to suit specification 3600 4100 4500

70mm ‘I’ (0.70) 12.5 1 Plasterboard to suit specification 4000 4600 500070mm ‘I’ (0.70) 12.5 2 Plasterboard to suit specification 4000 4600 500070mm ‘I’ (0.70) 15 1 Plasterboard to suit specification 4000 4600 500070mm ‘I’ (0.70) 15 2 Plasterboard to suit specification 4000 4600 5000

92mm ‘I’ (0.90) 12.5 1 Plasterboard to suit specification 5300 6100 670092mm ‘I’ (0.90) 12.5 2 Plasterboard to suit specification 5300 6100 670092mm ‘I’ (0.90) 15 1 Plasterboard to suit specification 5300 6100 670092mm ‘I’ (0.90) 15 2 Plasterboard to suit specification 5300 6100 6700

146mm ‘I’ (0.90) 12.5 1 Plasterboard to suit specification 7500 8600 9400146mm ‘I’ (0.90) 12.5 2 Plasterboard to suit specification 7500 8600 9400146mm ‘I’ (0.90) 15 1 Plasterboard to suit specification 7500 8600 9400146mm ‘I’ (0.90) 15 2 Plasterboard to suit specification 7500 8600 9400

1 Maximum heights : Calculated based on a limiting deflection of L/240 at 200 Pascals (0.2kN/m2).

Page 12: Knauf Drywall Systems

22 23

Knauf AQUAPANEL® Interior System

Performance tablesFor more information on these and other system performances, please contact the Technical Services webchat at www.knauf.co.uk or email [email protected].

Dimensions (mm)Maximum height (mm) with

Stud centres at 600mm centres1

Acoustic sound reduction (dB Rw)2 Fire resistance period3

Boarding specificationStud, depth and

gauge Insulation Boarding specification Overall width [excluding finishes]

BS EN ISO 1040-2: 2010 BS 476: Part 221

1 layer of 12.5 Knauf AQUAPANEL® Indoor Acoustic 70 ‘C’ [0.6] Knauf Insulation Rocksilk®

Flexible Slab 50mm1 layer of 12.5

Knauf AQUAPANEL® Indoor 97 3000 48 60

1 layer of 12.5 Knauf Performance Plus Acoustic 70 ‘C’ [0.6] Knauf Insulation Rocksilk®

Flexible Slab 50mm1 layer of 12.5

Knauf AQUAPANEL® Indoor 97 3000 48 30

2 layers of 12.5 Knauf AQUAPANEL® Indoor Acoustic 70 ‘C’ [0.6] Knauf Insulation Rocksilk®

Flexible Slab 50mm2 layers of 12.5

Knauf AQUAPANEL® Indoor 122 3600 55 120

2 layers of 12.5 Knauf Performance Plus Acoustic 70 ‘C’ [0.6] Knauf Insulation Rocksilk®

Flexible Slab 50mm2 layers of 12.5

Knauf AQUAPANEL® Indoor 122 3600 55 120

2 layers of 12.5 Knauf AQUAPANEL® Indoor Acoustic 70 ‘C’ [0.6] Knauf Insulation Rocksilk®

Flexible Slab 50mm

1 x 12.5mm Knauf Performance Plus [inner layer], inclusion of VCL,

1 x 12.5mm Knauf AQUAPANEL® Indoor

122 3600 55 120

1 Maximum heights and fire resistance: Calculated based on a limiting deflection of L/500 at 200 Pascals (0.2kN/m2). Relate to the fire resistance of system in accordance with BS 476: Part 22: 1987 only.

2 Acoustic sound reduction dB (Rw) Systems tested in accordance with BS EN ISO 10140-1:2010+A2:2014.

3 Period in minutes: inclusive of Integrity & Insulation

Note: System performances for both fire resistance and sound insulation performances are for imperforate partitions, incorporating plasterboard/AQUAPANEL® Indoor with all outer joints taped and filled, in accordance with Knauf recommendations.

Page 13: Knauf Drywall Systems

24 25

Knauf Metal Furring (MF) Suspended Ceiling Membranes

Performance tablesFor more information on these and other system performances, please contact the Technical Services webchat at www.knauf.co.uk or email [email protected].

System configuration Fire resistance to EN:1364-2: 2015

2 layers of Knauf 12.5mm Fire Panel, fixed to Knauf MF Ceiling system 30 mins

2 layers of Knauf 15mm Fire Panel, underlined to Knauf MF Ceiling system.

Inclusion of Knauf Insulation Rocksilk® RS45 50mm 60 mins

NOTES:

1. Fire resistance period is from below the ceiling lining and into cavity space within suspended ceiling zone (irrespective of background). 2. Please ensure correct centres of MF components relate to weight of system. 3. Perimeter seal with Knauf Intumescent & Acoustic Mastic.

Intermediate (load-bearing) timber floor joist system

System configurationFire resistance performance to BS 476: Part 21

(Test load: 1.25kN/m2)

22mm timber chipboard flooring, 220 x 45mm solid timber joists at 600mm centres

[with 45x45mm noggins], underlined with 2 x 12.5mm Knauf Fire Panel

60 mins

Page 14: Knauf Drywall Systems

For nearly ninety years, Knauf has remained relentless, responsible and forward-looking in its pursuit of excellence.

We have grown our reputation through making sure we focus on the environments in which our products are employed – working together to develop the solutions our customers seek; challenging preconceptions of what is possible and always open to new ideas.

We recognise the importance of the buildings in which we all live, work and relax. We spend 90% of our lives inside buildings, so it is of the utmost importance that the homes we live in, the hospitals where we care for our sick, the schools in which we educate our children and the offi ces in which business operates are world class. Safe, comfortable, sustainable and enjoyable.

The extensive portfolio of products and systems from Knauf UK & Ireland is developed to support that vision.

As a business, we look to the future; building on the knowledge we have acquired with a planned programme of research and development to make sure we continue to keep ahead of current thinking. Experimenting, testing new solutions and working ever more closely with our partners at every stage of a building project: the designers, distributors, contractors and users to make sure the developments we work on are genuinely innovative, relevant and progressive.

Looking to the future also means that our business must be sustainable. We are always conscious of the wider

consequences of our actions, both today and tomorrow. In terms of our operation we work hard to minimise our impact on the environment and are proud of our recycling, waste reduction and energy effi ciency initiatives.

Furthermore, we recognise that our business is only successful if the people who work within it are supported, encouraged and inspired. Our employee development programmes ensure that every individual is offered the opportunity to learn and progress both professionally and personally. The result is an exceptional team.

Technical expertise is the foundation of our business, but this has to operate hand-in-hand with a secure focus on our customers. We work hard to ensure that our support, service and customer relations functions are responsive, accommodating and resourceful. We proactively seek feedback at every opportunity, ensuring our customers have a fast and easy route to pass on comment and suggestions which are then used to inform further development.

There is always more to do. Every business must continually improve to keep ahead. We are constantly evolving to meet new challenges and capitalise on new opportunities while never losing sight of our ultimate goal: to Build for the world we live in. Now, tomorrow and for the future.

Here at Knauf, we build for the world we live in

Commercial

Residential

Healthcare

Education

Page 15: Knauf Drywall Systems

KML100370

The information given in this publication is believed to be current and accurate as at the date of publication, but no warranty, express or implied is given. Updates will not be automatically issued.© Copyright Knauf 2021

Customer ServiceUK Tel: 0800 521 050Eire Tel: 01 4620739Email: [email protected]

Technical ServiceLive Webchat 09:00 –17:00 Email: [email protected]

LiteratureUK Tel: 03700 613 700Eire Tel: +44 3700 613 700

Websitewww.knauf.co.ukwww.knauf.ie

KnaufKemsley Fields Business ParkSittingbourneKent ME9 8SR

Knauf87 Broomhill RoadTallaghtDublin D24 WR85

KnaufUK

@Knauf_UK

@Knauf_UK

Knauf UK & Ireland