VT03.de Technical Information Drywall Systems 2019-09 Fastening of Loads to Knauf Wall and Ceiling Systems Knauf Traverses Knauf Sanistands Knauf Boards Knauf Anchoring Note on English translation / Hinweise zur englischen Fassung This is a translation of the technical information sheet valid in Germany. All stated details and properties are in compliance with the regulations of the German standards and building regulations. They are only applicable for the specified products, system components, application rules, and construction details in connection with the specifications of the respective cer- tificates and approvals. Knauf Gips KG denies any liability for applications outside of Germany as this requires changes acc. to the respective national standards and building regulations.

Fastening of Loads to Knauf Wall and Ceiling Systems

  • Upload
    others

  • View
    3

  • Download
    1

Embed Size (px)

Citation preview

Page 1: Fastening of Loads to Knauf Wall and Ceiling Systems

VT03deTechnical Information

Drywall Systems

2019-09

Fastening of Loads to Knauf Wall and Ceiling SystemsKnauf TraversesKnauf SanistandsKnauf BoardsKnauf Anchoring

Note on English translation Hinweise zur englischen FassungThis is a translation of the technical information sheet valid in Germany All stated details and properties are in compliance with the regulations of the German standards and building regulations They are only applicable for the specified products system components application rules and construction details in connection with the specifications of the respective cer-tificates and approvalsKnauf Gips KG denies any liability for applications outside of Germany as this requires changes acc to the respective national standards and building regulations

2

Usage instructionsNotes on the documentKnauf technical information documents are the planning and application basis for planners and professional installers with the application of Knauf systems The contained information and specifications constructions details and stated products are based unless otherwise stated on the certificates of usability (eg National Technical Test Certificate (abP) andor German National Technical Approvals (abZ)) valid at the date they are published as well as on the applicable standards In addition design and structural requirements and those regarding building physics (fire protection and sound insulation) are considered The contained construction details are examples and can be used in a similar way for various cladding variants of the respective system At the same time the demands made on fire resistance andor sound insulation as well as any necessary additional measures andor limitations must be observed

References to other documents Metal stud partitions see system data sheet W11de Knauf Metal Stud Partitions

Wood frame partitions see system data sheet W12de Knauf Wood Frame Partitions

Fire walls see system data sheet W13de Knauf Fire Walls Furring and linings see system data sheet W61de Knauf Furring and Linings Metal Stud Partitions AQUAPANELreg see system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Board Ceilings ndash suspended under solid ceilings see system data sheet D11de Knauf Board Ceilings

ContentsUsage instructions 2Intended use of Knauf Systems 2

Loads on partitions and furringsIntroduction 3Cantilever loads 4

Rating diagrams 4Fastening in the cladding 6

Fields of application 6Fixing loads 6Rating 7

Anchoring in the traverses 8Fields of application 8Fixing loads 8Rating 9Knauf multi-purpose traverses 10Knauf steel anchoring traverse with gypsum fibre insert 12Knauf steel anchoring traverse 14

Full-length Sanistand 15

Loads on board ceilingsFastening in the cladding grid 21Anchoring in the traverses 22

Knauf multi-purpose traverses 22

Board ceilings under wood joist ceilings see system data sheet D15de Knauf wood joist ceiling systems

Observe the product data sheets of the individual Knauf system components

Intended use of Knauf SystemsPlease observe the following

Caution

Knauf systems may only be used for the application cases as stated in the Knauf documentation In case third-party products or components are used they must be recommended or approved by Knauf Flawless application of productssystems assumes proper transport storage assembly installation and maintenance

3

Loads on partitions and furringsIntroduction

Loads on partitions and furringsPartitions and furrings as drywall constructions are mainly non-load bearing constructions in keeping with the DIN EN 1991 standard The excellent performance of the Knauf partitions in combination with additional measures such as installed traverses or metal laminated hard gypsum boards offers solutions for the implementation of constructional challengesThis technical information document contains recommendations for the fastening and fixing of loads on partitions and furrings in the form of

Cantilever loads from static superimposed loads (cabinets shelves heating elements)

Dynamic loads such as handrails folding handles and fold-down seats acc to DIN 18 040 Construction of accessible buildings

Attachment of the WC bidet and washbasin using sanitary mounts in metal stud partitions

Normative definition of the loads on lightweight partitions are defined for example in the DIN 4103 DIN 18183 as well as in acc to Code of Practice No 8 of the Bundesverband der Gipsindustrie eV German Gypsum AssociationCantilever loads as described in the DIN 4103 are considered to be permanent loads and apply for example to cabinetsDynamic loads result from folding handles and fold-down seats Dynamic loads are recurring loads effective for a short duration and are time-dependentFor folding handles a projection of 80 cm with a load of 100 kN is assumed for the following recommendations Fold-down seats are considered as a maximum load of 150 kN with a projection of 48 cm Sanistands are offered by different manufacturers and are described normatively depending on the application whether toilet pans or washbasins The fracture load for toilet pans acc to the EN 997 stipulates 400 kN and for washbasins acc to EN 14688 a load of 150 kN is stipulatedThe Knauf partition systems in the following have been examined for the case above and determined to be appropriate for the load

Note

Fasteners in acc to DIN 4103 section 515 are to be used The details contained in this technical information document have been tested in the course of mechanical tests by Knauf

Differentiation cantilever load fixing loadTwo aspects must be considered in the attachment of loads on partitions and furrings

Cantilever loads

F F F F F F F

F

FFF

F F F

The cantilever load acts as a linear distributed load on the entire wallpartition system ie the entire wall system must be specifically designed for the purpose and the load must be transferred to the supporting structure without permitting a structural failure or deformation which exceed the limits of serviceability

Fixing loads

FF

The fastening of cantilever loads to partition systems are undertaken over several anchoring points which must be considered separately with respect to their loadbearing capacity in dependence on the selected fasteneranchor and the cladding as well as the substrate (cladding profile traverse)

Knauf system benefits Regulated construction High crack resistance with coordinated gypsum board types Diamant Steel GKFI as a surface traverse for flexible attachment in the entire wall area even with subsequent installation

4

Loads on partitions and furringsCantilever loads

Rating diagrams

Cabinet widthCabinet depth

Cabin

et he

ight

ge 30

0 mm

le 600 mmle 1200 mm

Eccentricityle 300 mm

The specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of load resulting to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The following tables and diagrams are intended as an aid in the determination of the permissible cantilever loads with divergent eccentricity The values can be taken either from the tables or the diagrams

Up to 04 kNm (40 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 31 28 25 22 19 16600 465 42 375 33 285 24800 62 56 50 44 38 321000 775 70 625 55 475 401200 93 84 75 66 57 48

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

10

70

60

40

20

100

80

90

50

Cabinet depthmm 100 200 300 400 500 600

1000 800 600 400

30

Max permissible cabinet weight

kg

Cabinet width

mm1200

Up to 07 kNm (70 kgm) wall length Maximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

kg

Max permissible cabinet weight

Cabinet width

mm1200

1000

400

600

800

mmCabinet depth

600100 200 300 400 500

10

70

60

40

20

30

100

80

90

110

120

50

5

Loads on partitions and furringsCantilever loads

Up to 10 kNm (100 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 90 80 70 60 50 40600 135 120 105 90 75 60800 180 160 140 120 100 801000 225 200 175 150 125 1001200 270 240 210 180 150 120

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagramMax permissible cabinet weight

kgCabinet width

mm1200

400

1000

600

800

Cabinet depthmm 600100 200 300 400 500

20

140

120

80

40

60

200

160

180

100

240

220

260

280

300

Up to 15 kNm (150 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 135 120 105 90 75 60600 202 180 157 135 112 90800 270 240 210 180 150 1201000 337 300 262 225 187 1501200 360 360 315 270 225 180

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

400

mm

1000

1200

600

800

Max permissible cabinet weight

kgCabinet width

Cabinet depthmm 600500400300200100

20

140

120

80

40

60

200

160

180

100

240

220

260

280

300

320

340

6

Loads on partitions and furringsFastening in the cladding

Fields of applicationAccording to DIN 18183 the metal stud partitions and independent furrings can be loaded at any position by cantilever loads

Up to 04 kNm (40 kgm) wall length Cladding thickness ge 125 mm Knauf boards Up to 07 kNm (70 kgm) wall length Cladding thickness ge 15 mm Diamant (in acc to abP P-140592810) ge 18 mm Knauf boards

With Diamant Steel GKFI and a cover layer ge 125 mm Diamant GKFI (see following table) cantilever loads up to 15 kNm (150 kgm) on walls are possible

Selection of the grid in dependence on the expected loadLoad max Load

typeProfile min Cladding thickness min Furring

possibleLoaded side Unloaded sideKn

auf

Boar

ds

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

Knau

f Bo

ards

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

tmm

tmmkNm2

04 StaticCW 50 125 125 YesCW 50 125 125 Yes

07 StaticCW 50 125 + 04 125 + 04 Yes 2)

CW 75 18 18 Yes 2)

CW 75 15 15 Yes 2)

10 StaticCW 50

125 + 041) + 125 2x 125 Yes

CW 75 125 + 04 125 No

15 Static CW 75 125 + 04

+ 125 2x 125 No

1)ScrewspacingDrywallScrewsXTB1stlayerDiamantSteelGKFIle250mm2)IncaseofapplicationofpartitionheightsacctoDIN18183-1onlycantileverloadsupto04kNmarepossible

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgX-hooks Knauf Cavity Dowel

HartmutScrew M5

fischer MHD 5 x 65 SScrew M5 or M6

Knauf Multi-Purpose Screw FN 43 x 65

Plastic cavity dowelOslash 8 or 10 mm

Diamant125 mm 5 10 15 40 20 13 3015 18 mm 5 10 15 45 25 14 352x 125 mm 5 10 15 60 30 20 45ge 2x 125 mm 5 10 15 65 35 40 50Diamant Steel GKFI1x 125 + 04 mm 5 10 15 80 50 30 30 3)

2x 125 + 04 mm 5 10 15 100 90 60 55 3)

Measuredwith300mmeccentricity3)ValuesapplywithfischerplasticcavitydowelsUX8x50withKnaufMulti-PurposeScrewFN43x65orequivalent

Notes

Static loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles The use of traverses is required here see page 8Always screw fasten Diamant Steel GKFI with Diamant Screws XTB even for a cover layer of Diamant

7

Loads on partitions and furringsAnchoring in the cladding

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 125 mm Diamant GKFI acc to tableField of application static load max cantilever load 04 kNm (40 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600

400 31 28 25 22 19 16

600 465 42 375 33 285 24

800 62 56 50 44 38 32

1000 775 70 625 55 475 40

1200 93 84 75 66 57 48

Cabinet depth 400 mm cabinet width 1000 mm Max cabinet weight 55 kg

Cladding thickness 125 mm plastic cavity dowel

Max dowel load 30 kg

Required number of dowels 55 kg 30 kg = 18 2 dowels

are the min necessary

Metal stud partition W111de CW 75 cladding 2x 125 mm Diamant GKFI acc to diagramField of application static load max cantilever load 07 kNm (70 kgm) wall length

400

mm12001000

600

100 200 400 500 600mm

10

70

60

40

20 30

kg

100

80 90

110120

800

300

50

1

23

450

65

Cabinet depth

Cabinet width

Max permissible cabinet weightCabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left ndash read off value 3

Max cabinet weight 65 kg

Cladding thickness 2x 125 mm Knauf Cavity Dowel Hartmut

Max dowel load 60 kg

Required number of dowels 65 kg 60 kg = 108 2 dowels

are the min necessary

8

Fields of applicationTraverses are built-in elements in lightweight partitions that transfer the fastening loads directly into the grid or into the flanking solid constructions

Selection of the traverse and grid in dependence on the expected loadFastening Load max Load type Profile min Cladding thickness min Independent

furring possible

Knauf Boards DiamantkNm2 mm mm

Steel anchoring traversesee page 14

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes

Metal traverse with gypsum fibre insertsee page 12

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Multi-purpose traversesee page 10

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgKnauf Cavity Dowel Hartmut

fischer MHD 5 x 65 S

Knauf Multi- Purpose Screw FN 43 x 65

fischer plastic cavity dowels 8 x 50 with Knauf Multi-Purpose Screw FN 43 x 65

Wood screw Oslash 50 mm

Wood screw Oslash 60 mm

TraversesSteel anchoring traverse 75 ndash 45 40 45 45

Metal traversewith gypsum fibre insert

90 75 65 46 55 70

Multi-purpose traverse ndash ndash 125 ndash 115 165

Measuredwith300mmeccentricity

Loads on partitions and furringsAnchoring in the traverses

NotesStatic loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles

9

Loads on partitions and furringsAnchoring in the traverses

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 18 mm Knauf board acc to tableField of application static load max cantilever load 07 kNm (70 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Cabinet depth 500 mm cabinet width 800 mm Max cabinet weight 62 kg Fixing traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 45 kg

Required number of screws 62 kg 45 kg = 14 2 screws

are the min necessary

Metal stud partition W111de UA 75 cladding 15 mm Diamant GKFI acc to diagram

Field of application dynamic load max cantilever load 15 kNm (150 kgm) wall length

20

400

Cabinet depth100 200 600

Max permissible cabinet weight

140120

80

4060

kg

200

160

180

Cabinet width

mm

1000

1200

600

mm 300

100 800

240220

260280300320340

450400 500

165

1

23

Cabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left read off value 3

Max cabinet weight 165 kg

Multi-purpose traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 125 kg

Required number of screws 165 kg 125 kg = 13 2 screws

are the min necessary

10

Knauf multi-purpose traversesThe multi-purpose traverse is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards boilers folding wall attached seats folding handles and similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the floor-to-ceiling profilesThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FN

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Loads on partitions and furringsAnchoring in the traverses

Installation and applicationMulti-purpose traverse made of multi-layer wooden board and galvanized sheet metal profiles attached to the side of the CW studs UA profiles For CW studs screw fasten using the 6 enclosed Metal Screws LN 35 x 11 mm (3 per side) For UA profiles screw fasten with the 6 enclosed Drilling Screws ST 42 x 13 mm (3 per side)Arrangement in a rowUA profiles CW studs

Direction of installation Direction of installation

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 2: Fastening of Loads to Knauf Wall and Ceiling Systems

2

Usage instructionsNotes on the documentKnauf technical information documents are the planning and application basis for planners and professional installers with the application of Knauf systems The contained information and specifications constructions details and stated products are based unless otherwise stated on the certificates of usability (eg National Technical Test Certificate (abP) andor German National Technical Approvals (abZ)) valid at the date they are published as well as on the applicable standards In addition design and structural requirements and those regarding building physics (fire protection and sound insulation) are considered The contained construction details are examples and can be used in a similar way for various cladding variants of the respective system At the same time the demands made on fire resistance andor sound insulation as well as any necessary additional measures andor limitations must be observed

References to other documents Metal stud partitions see system data sheet W11de Knauf Metal Stud Partitions

Wood frame partitions see system data sheet W12de Knauf Wood Frame Partitions

Fire walls see system data sheet W13de Knauf Fire Walls Furring and linings see system data sheet W61de Knauf Furring and Linings Metal Stud Partitions AQUAPANELreg see system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Board Ceilings ndash suspended under solid ceilings see system data sheet D11de Knauf Board Ceilings

ContentsUsage instructions 2Intended use of Knauf Systems 2

Loads on partitions and furringsIntroduction 3Cantilever loads 4

Rating diagrams 4Fastening in the cladding 6

Fields of application 6Fixing loads 6Rating 7

Anchoring in the traverses 8Fields of application 8Fixing loads 8Rating 9Knauf multi-purpose traverses 10Knauf steel anchoring traverse with gypsum fibre insert 12Knauf steel anchoring traverse 14

Full-length Sanistand 15

Loads on board ceilingsFastening in the cladding grid 21Anchoring in the traverses 22

Knauf multi-purpose traverses 22

Board ceilings under wood joist ceilings see system data sheet D15de Knauf wood joist ceiling systems

Observe the product data sheets of the individual Knauf system components

Intended use of Knauf SystemsPlease observe the following

Caution

Knauf systems may only be used for the application cases as stated in the Knauf documentation In case third-party products or components are used they must be recommended or approved by Knauf Flawless application of productssystems assumes proper transport storage assembly installation and maintenance

3

Loads on partitions and furringsIntroduction

Loads on partitions and furringsPartitions and furrings as drywall constructions are mainly non-load bearing constructions in keeping with the DIN EN 1991 standard The excellent performance of the Knauf partitions in combination with additional measures such as installed traverses or metal laminated hard gypsum boards offers solutions for the implementation of constructional challengesThis technical information document contains recommendations for the fastening and fixing of loads on partitions and furrings in the form of

Cantilever loads from static superimposed loads (cabinets shelves heating elements)

Dynamic loads such as handrails folding handles and fold-down seats acc to DIN 18 040 Construction of accessible buildings

Attachment of the WC bidet and washbasin using sanitary mounts in metal stud partitions

Normative definition of the loads on lightweight partitions are defined for example in the DIN 4103 DIN 18183 as well as in acc to Code of Practice No 8 of the Bundesverband der Gipsindustrie eV German Gypsum AssociationCantilever loads as described in the DIN 4103 are considered to be permanent loads and apply for example to cabinetsDynamic loads result from folding handles and fold-down seats Dynamic loads are recurring loads effective for a short duration and are time-dependentFor folding handles a projection of 80 cm with a load of 100 kN is assumed for the following recommendations Fold-down seats are considered as a maximum load of 150 kN with a projection of 48 cm Sanistands are offered by different manufacturers and are described normatively depending on the application whether toilet pans or washbasins The fracture load for toilet pans acc to the EN 997 stipulates 400 kN and for washbasins acc to EN 14688 a load of 150 kN is stipulatedThe Knauf partition systems in the following have been examined for the case above and determined to be appropriate for the load

Note

Fasteners in acc to DIN 4103 section 515 are to be used The details contained in this technical information document have been tested in the course of mechanical tests by Knauf

Differentiation cantilever load fixing loadTwo aspects must be considered in the attachment of loads on partitions and furrings

Cantilever loads

F F F F F F F

F

FFF

F F F

The cantilever load acts as a linear distributed load on the entire wallpartition system ie the entire wall system must be specifically designed for the purpose and the load must be transferred to the supporting structure without permitting a structural failure or deformation which exceed the limits of serviceability

Fixing loads

FF

The fastening of cantilever loads to partition systems are undertaken over several anchoring points which must be considered separately with respect to their loadbearing capacity in dependence on the selected fasteneranchor and the cladding as well as the substrate (cladding profile traverse)

Knauf system benefits Regulated construction High crack resistance with coordinated gypsum board types Diamant Steel GKFI as a surface traverse for flexible attachment in the entire wall area even with subsequent installation

4

Loads on partitions and furringsCantilever loads

Rating diagrams

Cabinet widthCabinet depth

Cabin

et he

ight

ge 30

0 mm

le 600 mmle 1200 mm

Eccentricityle 300 mm

The specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of load resulting to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The following tables and diagrams are intended as an aid in the determination of the permissible cantilever loads with divergent eccentricity The values can be taken either from the tables or the diagrams

Up to 04 kNm (40 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 31 28 25 22 19 16600 465 42 375 33 285 24800 62 56 50 44 38 321000 775 70 625 55 475 401200 93 84 75 66 57 48

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

10

70

60

40

20

100

80

90

50

Cabinet depthmm 100 200 300 400 500 600

1000 800 600 400

30

Max permissible cabinet weight

kg

Cabinet width

mm1200

Up to 07 kNm (70 kgm) wall length Maximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

kg

Max permissible cabinet weight

Cabinet width

mm1200

1000

400

600

800

mmCabinet depth

600100 200 300 400 500

10

70

60

40

20

30

100

80

90

110

120

50

5

Loads on partitions and furringsCantilever loads

Up to 10 kNm (100 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 90 80 70 60 50 40600 135 120 105 90 75 60800 180 160 140 120 100 801000 225 200 175 150 125 1001200 270 240 210 180 150 120

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagramMax permissible cabinet weight

kgCabinet width

mm1200

400

1000

600

800

Cabinet depthmm 600100 200 300 400 500

20

140

120

80

40

60

200

160

180

100

240

220

260

280

300

Up to 15 kNm (150 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 135 120 105 90 75 60600 202 180 157 135 112 90800 270 240 210 180 150 1201000 337 300 262 225 187 1501200 360 360 315 270 225 180

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

400

mm

1000

1200

600

800

Max permissible cabinet weight

kgCabinet width

Cabinet depthmm 600500400300200100

20

140

120

80

40

60

200

160

180

100

240

220

260

280

300

320

340

6

Loads on partitions and furringsFastening in the cladding

Fields of applicationAccording to DIN 18183 the metal stud partitions and independent furrings can be loaded at any position by cantilever loads

Up to 04 kNm (40 kgm) wall length Cladding thickness ge 125 mm Knauf boards Up to 07 kNm (70 kgm) wall length Cladding thickness ge 15 mm Diamant (in acc to abP P-140592810) ge 18 mm Knauf boards

With Diamant Steel GKFI and a cover layer ge 125 mm Diamant GKFI (see following table) cantilever loads up to 15 kNm (150 kgm) on walls are possible

Selection of the grid in dependence on the expected loadLoad max Load

typeProfile min Cladding thickness min Furring

possibleLoaded side Unloaded sideKn

auf

Boar

ds

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

Knau

f Bo

ards

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

tmm

tmmkNm2

04 StaticCW 50 125 125 YesCW 50 125 125 Yes

07 StaticCW 50 125 + 04 125 + 04 Yes 2)

CW 75 18 18 Yes 2)

CW 75 15 15 Yes 2)

10 StaticCW 50

125 + 041) + 125 2x 125 Yes

CW 75 125 + 04 125 No

15 Static CW 75 125 + 04

+ 125 2x 125 No

1)ScrewspacingDrywallScrewsXTB1stlayerDiamantSteelGKFIle250mm2)IncaseofapplicationofpartitionheightsacctoDIN18183-1onlycantileverloadsupto04kNmarepossible

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgX-hooks Knauf Cavity Dowel

HartmutScrew M5

fischer MHD 5 x 65 SScrew M5 or M6

Knauf Multi-Purpose Screw FN 43 x 65

Plastic cavity dowelOslash 8 or 10 mm

Diamant125 mm 5 10 15 40 20 13 3015 18 mm 5 10 15 45 25 14 352x 125 mm 5 10 15 60 30 20 45ge 2x 125 mm 5 10 15 65 35 40 50Diamant Steel GKFI1x 125 + 04 mm 5 10 15 80 50 30 30 3)

2x 125 + 04 mm 5 10 15 100 90 60 55 3)

Measuredwith300mmeccentricity3)ValuesapplywithfischerplasticcavitydowelsUX8x50withKnaufMulti-PurposeScrewFN43x65orequivalent

Notes

Static loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles The use of traverses is required here see page 8Always screw fasten Diamant Steel GKFI with Diamant Screws XTB even for a cover layer of Diamant

7

Loads on partitions and furringsAnchoring in the cladding

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 125 mm Diamant GKFI acc to tableField of application static load max cantilever load 04 kNm (40 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600

400 31 28 25 22 19 16

600 465 42 375 33 285 24

800 62 56 50 44 38 32

1000 775 70 625 55 475 40

1200 93 84 75 66 57 48

Cabinet depth 400 mm cabinet width 1000 mm Max cabinet weight 55 kg

Cladding thickness 125 mm plastic cavity dowel

Max dowel load 30 kg

Required number of dowels 55 kg 30 kg = 18 2 dowels

are the min necessary

Metal stud partition W111de CW 75 cladding 2x 125 mm Diamant GKFI acc to diagramField of application static load max cantilever load 07 kNm (70 kgm) wall length

400

mm12001000

600

100 200 400 500 600mm

10

70

60

40

20 30

kg

100

80 90

110120

800

300

50

1

23

450

65

Cabinet depth

Cabinet width

Max permissible cabinet weightCabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left ndash read off value 3

Max cabinet weight 65 kg

Cladding thickness 2x 125 mm Knauf Cavity Dowel Hartmut

Max dowel load 60 kg

Required number of dowels 65 kg 60 kg = 108 2 dowels

are the min necessary

8

Fields of applicationTraverses are built-in elements in lightweight partitions that transfer the fastening loads directly into the grid or into the flanking solid constructions

Selection of the traverse and grid in dependence on the expected loadFastening Load max Load type Profile min Cladding thickness min Independent

furring possible

Knauf Boards DiamantkNm2 mm mm

Steel anchoring traversesee page 14

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes

Metal traverse with gypsum fibre insertsee page 12

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Multi-purpose traversesee page 10

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgKnauf Cavity Dowel Hartmut

fischer MHD 5 x 65 S

Knauf Multi- Purpose Screw FN 43 x 65

fischer plastic cavity dowels 8 x 50 with Knauf Multi-Purpose Screw FN 43 x 65

Wood screw Oslash 50 mm

Wood screw Oslash 60 mm

TraversesSteel anchoring traverse 75 ndash 45 40 45 45

Metal traversewith gypsum fibre insert

90 75 65 46 55 70

Multi-purpose traverse ndash ndash 125 ndash 115 165

Measuredwith300mmeccentricity

Loads on partitions and furringsAnchoring in the traverses

NotesStatic loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles

9

Loads on partitions and furringsAnchoring in the traverses

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 18 mm Knauf board acc to tableField of application static load max cantilever load 07 kNm (70 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Cabinet depth 500 mm cabinet width 800 mm Max cabinet weight 62 kg Fixing traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 45 kg

Required number of screws 62 kg 45 kg = 14 2 screws

are the min necessary

Metal stud partition W111de UA 75 cladding 15 mm Diamant GKFI acc to diagram

Field of application dynamic load max cantilever load 15 kNm (150 kgm) wall length

20

400

Cabinet depth100 200 600

Max permissible cabinet weight

140120

80

4060

kg

200

160

180

Cabinet width

mm

1000

1200

600

mm 300

100 800

240220

260280300320340

450400 500

165

1

23

Cabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left read off value 3

Max cabinet weight 165 kg

Multi-purpose traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 125 kg

Required number of screws 165 kg 125 kg = 13 2 screws

are the min necessary

10

Knauf multi-purpose traversesThe multi-purpose traverse is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards boilers folding wall attached seats folding handles and similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the floor-to-ceiling profilesThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FN

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Loads on partitions and furringsAnchoring in the traverses

Installation and applicationMulti-purpose traverse made of multi-layer wooden board and galvanized sheet metal profiles attached to the side of the CW studs UA profiles For CW studs screw fasten using the 6 enclosed Metal Screws LN 35 x 11 mm (3 per side) For UA profiles screw fasten with the 6 enclosed Drilling Screws ST 42 x 13 mm (3 per side)Arrangement in a rowUA profiles CW studs

Direction of installation Direction of installation

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 3: Fastening of Loads to Knauf Wall and Ceiling Systems

3

Loads on partitions and furringsIntroduction

Loads on partitions and furringsPartitions and furrings as drywall constructions are mainly non-load bearing constructions in keeping with the DIN EN 1991 standard The excellent performance of the Knauf partitions in combination with additional measures such as installed traverses or metal laminated hard gypsum boards offers solutions for the implementation of constructional challengesThis technical information document contains recommendations for the fastening and fixing of loads on partitions and furrings in the form of

Cantilever loads from static superimposed loads (cabinets shelves heating elements)

Dynamic loads such as handrails folding handles and fold-down seats acc to DIN 18 040 Construction of accessible buildings

Attachment of the WC bidet and washbasin using sanitary mounts in metal stud partitions

Normative definition of the loads on lightweight partitions are defined for example in the DIN 4103 DIN 18183 as well as in acc to Code of Practice No 8 of the Bundesverband der Gipsindustrie eV German Gypsum AssociationCantilever loads as described in the DIN 4103 are considered to be permanent loads and apply for example to cabinetsDynamic loads result from folding handles and fold-down seats Dynamic loads are recurring loads effective for a short duration and are time-dependentFor folding handles a projection of 80 cm with a load of 100 kN is assumed for the following recommendations Fold-down seats are considered as a maximum load of 150 kN with a projection of 48 cm Sanistands are offered by different manufacturers and are described normatively depending on the application whether toilet pans or washbasins The fracture load for toilet pans acc to the EN 997 stipulates 400 kN and for washbasins acc to EN 14688 a load of 150 kN is stipulatedThe Knauf partition systems in the following have been examined for the case above and determined to be appropriate for the load

Note

Fasteners in acc to DIN 4103 section 515 are to be used The details contained in this technical information document have been tested in the course of mechanical tests by Knauf

Differentiation cantilever load fixing loadTwo aspects must be considered in the attachment of loads on partitions and furrings

Cantilever loads

F F F F F F F

F

FFF

F F F

The cantilever load acts as a linear distributed load on the entire wallpartition system ie the entire wall system must be specifically designed for the purpose and the load must be transferred to the supporting structure without permitting a structural failure or deformation which exceed the limits of serviceability

Fixing loads

FF

The fastening of cantilever loads to partition systems are undertaken over several anchoring points which must be considered separately with respect to their loadbearing capacity in dependence on the selected fasteneranchor and the cladding as well as the substrate (cladding profile traverse)

Knauf system benefits Regulated construction High crack resistance with coordinated gypsum board types Diamant Steel GKFI as a surface traverse for flexible attachment in the entire wall area even with subsequent installation

4

Loads on partitions and furringsCantilever loads

Rating diagrams

Cabinet widthCabinet depth

Cabin

et he

ight

ge 30

0 mm

le 600 mmle 1200 mm

Eccentricityle 300 mm

The specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of load resulting to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The following tables and diagrams are intended as an aid in the determination of the permissible cantilever loads with divergent eccentricity The values can be taken either from the tables or the diagrams

Up to 04 kNm (40 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 31 28 25 22 19 16600 465 42 375 33 285 24800 62 56 50 44 38 321000 775 70 625 55 475 401200 93 84 75 66 57 48

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

10

70

60

40

20

100

80

90

50

Cabinet depthmm 100 200 300 400 500 600

1000 800 600 400

30

Max permissible cabinet weight

kg

Cabinet width

mm1200

Up to 07 kNm (70 kgm) wall length Maximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

kg

Max permissible cabinet weight

Cabinet width

mm1200

1000

400

600

800

mmCabinet depth

600100 200 300 400 500

10

70

60

40

20

30

100

80

90

110

120

50

5

Loads on partitions and furringsCantilever loads

Up to 10 kNm (100 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 90 80 70 60 50 40600 135 120 105 90 75 60800 180 160 140 120 100 801000 225 200 175 150 125 1001200 270 240 210 180 150 120

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagramMax permissible cabinet weight

kgCabinet width

mm1200

400

1000

600

800

Cabinet depthmm 600100 200 300 400 500

20

140

120

80

40

60

200

160

180

100

240

220

260

280

300

Up to 15 kNm (150 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 135 120 105 90 75 60600 202 180 157 135 112 90800 270 240 210 180 150 1201000 337 300 262 225 187 1501200 360 360 315 270 225 180

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

400

mm

1000

1200

600

800

Max permissible cabinet weight

kgCabinet width

Cabinet depthmm 600500400300200100

20

140

120

80

40

60

200

160

180

100

240

220

260

280

300

320

340

6

Loads on partitions and furringsFastening in the cladding

Fields of applicationAccording to DIN 18183 the metal stud partitions and independent furrings can be loaded at any position by cantilever loads

Up to 04 kNm (40 kgm) wall length Cladding thickness ge 125 mm Knauf boards Up to 07 kNm (70 kgm) wall length Cladding thickness ge 15 mm Diamant (in acc to abP P-140592810) ge 18 mm Knauf boards

With Diamant Steel GKFI and a cover layer ge 125 mm Diamant GKFI (see following table) cantilever loads up to 15 kNm (150 kgm) on walls are possible

Selection of the grid in dependence on the expected loadLoad max Load

typeProfile min Cladding thickness min Furring

possibleLoaded side Unloaded sideKn

auf

Boar

ds

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

Knau

f Bo

ards

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

tmm

tmmkNm2

04 StaticCW 50 125 125 YesCW 50 125 125 Yes

07 StaticCW 50 125 + 04 125 + 04 Yes 2)

CW 75 18 18 Yes 2)

CW 75 15 15 Yes 2)

10 StaticCW 50

125 + 041) + 125 2x 125 Yes

CW 75 125 + 04 125 No

15 Static CW 75 125 + 04

+ 125 2x 125 No

1)ScrewspacingDrywallScrewsXTB1stlayerDiamantSteelGKFIle250mm2)IncaseofapplicationofpartitionheightsacctoDIN18183-1onlycantileverloadsupto04kNmarepossible

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgX-hooks Knauf Cavity Dowel

HartmutScrew M5

fischer MHD 5 x 65 SScrew M5 or M6

Knauf Multi-Purpose Screw FN 43 x 65

Plastic cavity dowelOslash 8 or 10 mm

Diamant125 mm 5 10 15 40 20 13 3015 18 mm 5 10 15 45 25 14 352x 125 mm 5 10 15 60 30 20 45ge 2x 125 mm 5 10 15 65 35 40 50Diamant Steel GKFI1x 125 + 04 mm 5 10 15 80 50 30 30 3)

2x 125 + 04 mm 5 10 15 100 90 60 55 3)

Measuredwith300mmeccentricity3)ValuesapplywithfischerplasticcavitydowelsUX8x50withKnaufMulti-PurposeScrewFN43x65orequivalent

Notes

Static loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles The use of traverses is required here see page 8Always screw fasten Diamant Steel GKFI with Diamant Screws XTB even for a cover layer of Diamant

7

Loads on partitions and furringsAnchoring in the cladding

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 125 mm Diamant GKFI acc to tableField of application static load max cantilever load 04 kNm (40 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600

400 31 28 25 22 19 16

600 465 42 375 33 285 24

800 62 56 50 44 38 32

1000 775 70 625 55 475 40

1200 93 84 75 66 57 48

Cabinet depth 400 mm cabinet width 1000 mm Max cabinet weight 55 kg

Cladding thickness 125 mm plastic cavity dowel

Max dowel load 30 kg

Required number of dowels 55 kg 30 kg = 18 2 dowels

are the min necessary

Metal stud partition W111de CW 75 cladding 2x 125 mm Diamant GKFI acc to diagramField of application static load max cantilever load 07 kNm (70 kgm) wall length

400

mm12001000

600

100 200 400 500 600mm

10

70

60

40

20 30

kg

100

80 90

110120

800

300

50

1

23

450

65

Cabinet depth

Cabinet width

Max permissible cabinet weightCabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left ndash read off value 3

Max cabinet weight 65 kg

Cladding thickness 2x 125 mm Knauf Cavity Dowel Hartmut

Max dowel load 60 kg

Required number of dowels 65 kg 60 kg = 108 2 dowels

are the min necessary

8

Fields of applicationTraverses are built-in elements in lightweight partitions that transfer the fastening loads directly into the grid or into the flanking solid constructions

Selection of the traverse and grid in dependence on the expected loadFastening Load max Load type Profile min Cladding thickness min Independent

furring possible

Knauf Boards DiamantkNm2 mm mm

Steel anchoring traversesee page 14

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes

Metal traverse with gypsum fibre insertsee page 12

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Multi-purpose traversesee page 10

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgKnauf Cavity Dowel Hartmut

fischer MHD 5 x 65 S

Knauf Multi- Purpose Screw FN 43 x 65

fischer plastic cavity dowels 8 x 50 with Knauf Multi-Purpose Screw FN 43 x 65

Wood screw Oslash 50 mm

Wood screw Oslash 60 mm

TraversesSteel anchoring traverse 75 ndash 45 40 45 45

Metal traversewith gypsum fibre insert

90 75 65 46 55 70

Multi-purpose traverse ndash ndash 125 ndash 115 165

Measuredwith300mmeccentricity

Loads on partitions and furringsAnchoring in the traverses

NotesStatic loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles

9

Loads on partitions and furringsAnchoring in the traverses

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 18 mm Knauf board acc to tableField of application static load max cantilever load 07 kNm (70 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Cabinet depth 500 mm cabinet width 800 mm Max cabinet weight 62 kg Fixing traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 45 kg

Required number of screws 62 kg 45 kg = 14 2 screws

are the min necessary

Metal stud partition W111de UA 75 cladding 15 mm Diamant GKFI acc to diagram

Field of application dynamic load max cantilever load 15 kNm (150 kgm) wall length

20

400

Cabinet depth100 200 600

Max permissible cabinet weight

140120

80

4060

kg

200

160

180

Cabinet width

mm

1000

1200

600

mm 300

100 800

240220

260280300320340

450400 500

165

1

23

Cabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left read off value 3

Max cabinet weight 165 kg

Multi-purpose traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 125 kg

Required number of screws 165 kg 125 kg = 13 2 screws

are the min necessary

10

Knauf multi-purpose traversesThe multi-purpose traverse is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards boilers folding wall attached seats folding handles and similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the floor-to-ceiling profilesThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FN

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Loads on partitions and furringsAnchoring in the traverses

Installation and applicationMulti-purpose traverse made of multi-layer wooden board and galvanized sheet metal profiles attached to the side of the CW studs UA profiles For CW studs screw fasten using the 6 enclosed Metal Screws LN 35 x 11 mm (3 per side) For UA profiles screw fasten with the 6 enclosed Drilling Screws ST 42 x 13 mm (3 per side)Arrangement in a rowUA profiles CW studs

Direction of installation Direction of installation

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 4: Fastening of Loads to Knauf Wall and Ceiling Systems

4

Loads on partitions and furringsCantilever loads

Rating diagrams

Cabinet widthCabinet depth

Cabin

et he

ight

ge 30

0 mm

le 600 mmle 1200 mm

Eccentricityle 300 mm

The specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of load resulting to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The following tables and diagrams are intended as an aid in the determination of the permissible cantilever loads with divergent eccentricity The values can be taken either from the tables or the diagrams

Up to 04 kNm (40 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 31 28 25 22 19 16600 465 42 375 33 285 24800 62 56 50 44 38 321000 775 70 625 55 475 401200 93 84 75 66 57 48

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

10

70

60

40

20

100

80

90

50

Cabinet depthmm 100 200 300 400 500 600

1000 800 600 400

30

Max permissible cabinet weight

kg

Cabinet width

mm1200

Up to 07 kNm (70 kgm) wall length Maximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

kg

Max permissible cabinet weight

Cabinet width

mm1200

1000

400

600

800

mmCabinet depth

600100 200 300 400 500

10

70

60

40

20

30

100

80

90

110

120

50

5

Loads on partitions and furringsCantilever loads

Up to 10 kNm (100 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 90 80 70 60 50 40600 135 120 105 90 75 60800 180 160 140 120 100 801000 225 200 175 150 125 1001200 270 240 210 180 150 120

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagramMax permissible cabinet weight

kgCabinet width

mm1200

400

1000

600

800

Cabinet depthmm 600100 200 300 400 500

20

140

120

80

40

60

200

160

180

100

240

220

260

280

300

Up to 15 kNm (150 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 135 120 105 90 75 60600 202 180 157 135 112 90800 270 240 210 180 150 1201000 337 300 262 225 187 1501200 360 360 315 270 225 180

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

400

mm

1000

1200

600

800

Max permissible cabinet weight

kgCabinet width

Cabinet depthmm 600500400300200100

20

140

120

80

40

60

200

160

180

100

240

220

260

280

300

320

340

6

Loads on partitions and furringsFastening in the cladding

Fields of applicationAccording to DIN 18183 the metal stud partitions and independent furrings can be loaded at any position by cantilever loads

Up to 04 kNm (40 kgm) wall length Cladding thickness ge 125 mm Knauf boards Up to 07 kNm (70 kgm) wall length Cladding thickness ge 15 mm Diamant (in acc to abP P-140592810) ge 18 mm Knauf boards

With Diamant Steel GKFI and a cover layer ge 125 mm Diamant GKFI (see following table) cantilever loads up to 15 kNm (150 kgm) on walls are possible

Selection of the grid in dependence on the expected loadLoad max Load

typeProfile min Cladding thickness min Furring

possibleLoaded side Unloaded sideKn

auf

Boar

ds

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

Knau

f Bo

ards

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

tmm

tmmkNm2

04 StaticCW 50 125 125 YesCW 50 125 125 Yes

07 StaticCW 50 125 + 04 125 + 04 Yes 2)

CW 75 18 18 Yes 2)

CW 75 15 15 Yes 2)

10 StaticCW 50

125 + 041) + 125 2x 125 Yes

CW 75 125 + 04 125 No

15 Static CW 75 125 + 04

+ 125 2x 125 No

1)ScrewspacingDrywallScrewsXTB1stlayerDiamantSteelGKFIle250mm2)IncaseofapplicationofpartitionheightsacctoDIN18183-1onlycantileverloadsupto04kNmarepossible

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgX-hooks Knauf Cavity Dowel

HartmutScrew M5

fischer MHD 5 x 65 SScrew M5 or M6

Knauf Multi-Purpose Screw FN 43 x 65

Plastic cavity dowelOslash 8 or 10 mm

Diamant125 mm 5 10 15 40 20 13 3015 18 mm 5 10 15 45 25 14 352x 125 mm 5 10 15 60 30 20 45ge 2x 125 mm 5 10 15 65 35 40 50Diamant Steel GKFI1x 125 + 04 mm 5 10 15 80 50 30 30 3)

2x 125 + 04 mm 5 10 15 100 90 60 55 3)

Measuredwith300mmeccentricity3)ValuesapplywithfischerplasticcavitydowelsUX8x50withKnaufMulti-PurposeScrewFN43x65orequivalent

Notes

Static loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles The use of traverses is required here see page 8Always screw fasten Diamant Steel GKFI with Diamant Screws XTB even for a cover layer of Diamant

7

Loads on partitions and furringsAnchoring in the cladding

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 125 mm Diamant GKFI acc to tableField of application static load max cantilever load 04 kNm (40 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600

400 31 28 25 22 19 16

600 465 42 375 33 285 24

800 62 56 50 44 38 32

1000 775 70 625 55 475 40

1200 93 84 75 66 57 48

Cabinet depth 400 mm cabinet width 1000 mm Max cabinet weight 55 kg

Cladding thickness 125 mm plastic cavity dowel

Max dowel load 30 kg

Required number of dowels 55 kg 30 kg = 18 2 dowels

are the min necessary

Metal stud partition W111de CW 75 cladding 2x 125 mm Diamant GKFI acc to diagramField of application static load max cantilever load 07 kNm (70 kgm) wall length

400

mm12001000

600

100 200 400 500 600mm

10

70

60

40

20 30

kg

100

80 90

110120

800

300

50

1

23

450

65

Cabinet depth

Cabinet width

Max permissible cabinet weightCabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left ndash read off value 3

Max cabinet weight 65 kg

Cladding thickness 2x 125 mm Knauf Cavity Dowel Hartmut

Max dowel load 60 kg

Required number of dowels 65 kg 60 kg = 108 2 dowels

are the min necessary

8

Fields of applicationTraverses are built-in elements in lightweight partitions that transfer the fastening loads directly into the grid or into the flanking solid constructions

Selection of the traverse and grid in dependence on the expected loadFastening Load max Load type Profile min Cladding thickness min Independent

furring possible

Knauf Boards DiamantkNm2 mm mm

Steel anchoring traversesee page 14

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes

Metal traverse with gypsum fibre insertsee page 12

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Multi-purpose traversesee page 10

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgKnauf Cavity Dowel Hartmut

fischer MHD 5 x 65 S

Knauf Multi- Purpose Screw FN 43 x 65

fischer plastic cavity dowels 8 x 50 with Knauf Multi-Purpose Screw FN 43 x 65

Wood screw Oslash 50 mm

Wood screw Oslash 60 mm

TraversesSteel anchoring traverse 75 ndash 45 40 45 45

Metal traversewith gypsum fibre insert

90 75 65 46 55 70

Multi-purpose traverse ndash ndash 125 ndash 115 165

Measuredwith300mmeccentricity

Loads on partitions and furringsAnchoring in the traverses

NotesStatic loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles

9

Loads on partitions and furringsAnchoring in the traverses

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 18 mm Knauf board acc to tableField of application static load max cantilever load 07 kNm (70 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Cabinet depth 500 mm cabinet width 800 mm Max cabinet weight 62 kg Fixing traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 45 kg

Required number of screws 62 kg 45 kg = 14 2 screws

are the min necessary

Metal stud partition W111de UA 75 cladding 15 mm Diamant GKFI acc to diagram

Field of application dynamic load max cantilever load 15 kNm (150 kgm) wall length

20

400

Cabinet depth100 200 600

Max permissible cabinet weight

140120

80

4060

kg

200

160

180

Cabinet width

mm

1000

1200

600

mm 300

100 800

240220

260280300320340

450400 500

165

1

23

Cabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left read off value 3

Max cabinet weight 165 kg

Multi-purpose traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 125 kg

Required number of screws 165 kg 125 kg = 13 2 screws

are the min necessary

10

Knauf multi-purpose traversesThe multi-purpose traverse is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards boilers folding wall attached seats folding handles and similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the floor-to-ceiling profilesThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FN

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Loads on partitions and furringsAnchoring in the traverses

Installation and applicationMulti-purpose traverse made of multi-layer wooden board and galvanized sheet metal profiles attached to the side of the CW studs UA profiles For CW studs screw fasten using the 6 enclosed Metal Screws LN 35 x 11 mm (3 per side) For UA profiles screw fasten with the 6 enclosed Drilling Screws ST 42 x 13 mm (3 per side)Arrangement in a rowUA profiles CW studs

Direction of installation Direction of installation

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 5: Fastening of Loads to Knauf Wall and Ceiling Systems

5

Loads on partitions and furringsCantilever loads

Up to 10 kNm (100 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 90 80 70 60 50 40600 135 120 105 90 75 60800 180 160 140 120 100 801000 225 200 175 150 125 1001200 270 240 210 180 150 120

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagramMax permissible cabinet weight

kgCabinet width

mm1200

400

1000

600

800

Cabinet depthmm 600100 200 300 400 500

20

140

120

80

40

60

200

160

180

100

240

220

260

280

300

Up to 15 kNm (150 kgm) wall lengthMaximum permissible cabinet weight (kg) acc to table

Cabinet widthmm

Cabinet depthmm100 200 300 400 500 600

400 135 120 105 90 75 60600 202 180 157 135 112 90800 270 240 210 180 150 1201000 337 300 262 225 187 1501200 360 360 315 270 225 180

Assume the worst-case value with intermediate values or diagram procedure

orMaximum permissible cabinet weight (kg) acc to diagram

400

mm

1000

1200

600

800

Max permissible cabinet weight

kgCabinet width

Cabinet depthmm 600500400300200100

20

140

120

80

40

60

200

160

180

100

240

220

260

280

300

320

340

6

Loads on partitions and furringsFastening in the cladding

Fields of applicationAccording to DIN 18183 the metal stud partitions and independent furrings can be loaded at any position by cantilever loads

Up to 04 kNm (40 kgm) wall length Cladding thickness ge 125 mm Knauf boards Up to 07 kNm (70 kgm) wall length Cladding thickness ge 15 mm Diamant (in acc to abP P-140592810) ge 18 mm Knauf boards

With Diamant Steel GKFI and a cover layer ge 125 mm Diamant GKFI (see following table) cantilever loads up to 15 kNm (150 kgm) on walls are possible

Selection of the grid in dependence on the expected loadLoad max Load

typeProfile min Cladding thickness min Furring

possibleLoaded side Unloaded sideKn

auf

Boar

ds

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

Knau

f Bo

ards

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

tmm

tmmkNm2

04 StaticCW 50 125 125 YesCW 50 125 125 Yes

07 StaticCW 50 125 + 04 125 + 04 Yes 2)

CW 75 18 18 Yes 2)

CW 75 15 15 Yes 2)

10 StaticCW 50

125 + 041) + 125 2x 125 Yes

CW 75 125 + 04 125 No

15 Static CW 75 125 + 04

+ 125 2x 125 No

1)ScrewspacingDrywallScrewsXTB1stlayerDiamantSteelGKFIle250mm2)IncaseofapplicationofpartitionheightsacctoDIN18183-1onlycantileverloadsupto04kNmarepossible

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgX-hooks Knauf Cavity Dowel

HartmutScrew M5

fischer MHD 5 x 65 SScrew M5 or M6

Knauf Multi-Purpose Screw FN 43 x 65

Plastic cavity dowelOslash 8 or 10 mm

Diamant125 mm 5 10 15 40 20 13 3015 18 mm 5 10 15 45 25 14 352x 125 mm 5 10 15 60 30 20 45ge 2x 125 mm 5 10 15 65 35 40 50Diamant Steel GKFI1x 125 + 04 mm 5 10 15 80 50 30 30 3)

2x 125 + 04 mm 5 10 15 100 90 60 55 3)

Measuredwith300mmeccentricity3)ValuesapplywithfischerplasticcavitydowelsUX8x50withKnaufMulti-PurposeScrewFN43x65orequivalent

Notes

Static loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles The use of traverses is required here see page 8Always screw fasten Diamant Steel GKFI with Diamant Screws XTB even for a cover layer of Diamant

7

Loads on partitions and furringsAnchoring in the cladding

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 125 mm Diamant GKFI acc to tableField of application static load max cantilever load 04 kNm (40 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600

400 31 28 25 22 19 16

600 465 42 375 33 285 24

800 62 56 50 44 38 32

1000 775 70 625 55 475 40

1200 93 84 75 66 57 48

Cabinet depth 400 mm cabinet width 1000 mm Max cabinet weight 55 kg

Cladding thickness 125 mm plastic cavity dowel

Max dowel load 30 kg

Required number of dowels 55 kg 30 kg = 18 2 dowels

are the min necessary

Metal stud partition W111de CW 75 cladding 2x 125 mm Diamant GKFI acc to diagramField of application static load max cantilever load 07 kNm (70 kgm) wall length

400

mm12001000

600

100 200 400 500 600mm

10

70

60

40

20 30

kg

100

80 90

110120

800

300

50

1

23

450

65

Cabinet depth

Cabinet width

Max permissible cabinet weightCabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left ndash read off value 3

Max cabinet weight 65 kg

Cladding thickness 2x 125 mm Knauf Cavity Dowel Hartmut

Max dowel load 60 kg

Required number of dowels 65 kg 60 kg = 108 2 dowels

are the min necessary

8

Fields of applicationTraverses are built-in elements in lightweight partitions that transfer the fastening loads directly into the grid or into the flanking solid constructions

Selection of the traverse and grid in dependence on the expected loadFastening Load max Load type Profile min Cladding thickness min Independent

furring possible

Knauf Boards DiamantkNm2 mm mm

Steel anchoring traversesee page 14

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes

Metal traverse with gypsum fibre insertsee page 12

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Multi-purpose traversesee page 10

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgKnauf Cavity Dowel Hartmut

fischer MHD 5 x 65 S

Knauf Multi- Purpose Screw FN 43 x 65

fischer plastic cavity dowels 8 x 50 with Knauf Multi-Purpose Screw FN 43 x 65

Wood screw Oslash 50 mm

Wood screw Oslash 60 mm

TraversesSteel anchoring traverse 75 ndash 45 40 45 45

Metal traversewith gypsum fibre insert

90 75 65 46 55 70

Multi-purpose traverse ndash ndash 125 ndash 115 165

Measuredwith300mmeccentricity

Loads on partitions and furringsAnchoring in the traverses

NotesStatic loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles

9

Loads on partitions and furringsAnchoring in the traverses

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 18 mm Knauf board acc to tableField of application static load max cantilever load 07 kNm (70 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Cabinet depth 500 mm cabinet width 800 mm Max cabinet weight 62 kg Fixing traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 45 kg

Required number of screws 62 kg 45 kg = 14 2 screws

are the min necessary

Metal stud partition W111de UA 75 cladding 15 mm Diamant GKFI acc to diagram

Field of application dynamic load max cantilever load 15 kNm (150 kgm) wall length

20

400

Cabinet depth100 200 600

Max permissible cabinet weight

140120

80

4060

kg

200

160

180

Cabinet width

mm

1000

1200

600

mm 300

100 800

240220

260280300320340

450400 500

165

1

23

Cabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left read off value 3

Max cabinet weight 165 kg

Multi-purpose traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 125 kg

Required number of screws 165 kg 125 kg = 13 2 screws

are the min necessary

10

Knauf multi-purpose traversesThe multi-purpose traverse is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards boilers folding wall attached seats folding handles and similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the floor-to-ceiling profilesThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FN

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Loads on partitions and furringsAnchoring in the traverses

Installation and applicationMulti-purpose traverse made of multi-layer wooden board and galvanized sheet metal profiles attached to the side of the CW studs UA profiles For CW studs screw fasten using the 6 enclosed Metal Screws LN 35 x 11 mm (3 per side) For UA profiles screw fasten with the 6 enclosed Drilling Screws ST 42 x 13 mm (3 per side)Arrangement in a rowUA profiles CW studs

Direction of installation Direction of installation

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 6: Fastening of Loads to Knauf Wall and Ceiling Systems

6

Loads on partitions and furringsFastening in the cladding

Fields of applicationAccording to DIN 18183 the metal stud partitions and independent furrings can be loaded at any position by cantilever loads

Up to 04 kNm (40 kgm) wall length Cladding thickness ge 125 mm Knauf boards Up to 07 kNm (70 kgm) wall length Cladding thickness ge 15 mm Diamant (in acc to abP P-140592810) ge 18 mm Knauf boards

With Diamant Steel GKFI and a cover layer ge 125 mm Diamant GKFI (see following table) cantilever loads up to 15 kNm (150 kgm) on walls are possible

Selection of the grid in dependence on the expected loadLoad max Load

typeProfile min Cladding thickness min Furring

possibleLoaded side Unloaded sideKn

auf

Boar

ds

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

Knau

f Bo

ards

Diam

ant

Diam

ant

Stee

l GKF

I Minimum thickness

tmm

tmmkNm2

04 StaticCW 50 125 125 YesCW 50 125 125 Yes

07 StaticCW 50 125 + 04 125 + 04 Yes 2)

CW 75 18 18 Yes 2)

CW 75 15 15 Yes 2)

10 StaticCW 50

125 + 041) + 125 2x 125 Yes

CW 75 125 + 04 125 No

15 Static CW 75 125 + 04

+ 125 2x 125 No

1)ScrewspacingDrywallScrewsXTB1stlayerDiamantSteelGKFIle250mm2)IncaseofapplicationofpartitionheightsacctoDIN18183-1onlycantileverloadsupto04kNmarepossible

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgX-hooks Knauf Cavity Dowel

HartmutScrew M5

fischer MHD 5 x 65 SScrew M5 or M6

Knauf Multi-Purpose Screw FN 43 x 65

Plastic cavity dowelOslash 8 or 10 mm

Diamant125 mm 5 10 15 40 20 13 3015 18 mm 5 10 15 45 25 14 352x 125 mm 5 10 15 60 30 20 45ge 2x 125 mm 5 10 15 65 35 40 50Diamant Steel GKFI1x 125 + 04 mm 5 10 15 80 50 30 30 3)

2x 125 + 04 mm 5 10 15 100 90 60 55 3)

Measuredwith300mmeccentricity3)ValuesapplywithfischerplasticcavitydowelsUX8x50withKnaufMulti-PurposeScrewFN43x65orequivalent

Notes

Static loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles The use of traverses is required here see page 8Always screw fasten Diamant Steel GKFI with Diamant Screws XTB even for a cover layer of Diamant

7

Loads on partitions and furringsAnchoring in the cladding

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 125 mm Diamant GKFI acc to tableField of application static load max cantilever load 04 kNm (40 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600

400 31 28 25 22 19 16

600 465 42 375 33 285 24

800 62 56 50 44 38 32

1000 775 70 625 55 475 40

1200 93 84 75 66 57 48

Cabinet depth 400 mm cabinet width 1000 mm Max cabinet weight 55 kg

Cladding thickness 125 mm plastic cavity dowel

Max dowel load 30 kg

Required number of dowels 55 kg 30 kg = 18 2 dowels

are the min necessary

Metal stud partition W111de CW 75 cladding 2x 125 mm Diamant GKFI acc to diagramField of application static load max cantilever load 07 kNm (70 kgm) wall length

400

mm12001000

600

100 200 400 500 600mm

10

70

60

40

20 30

kg

100

80 90

110120

800

300

50

1

23

450

65

Cabinet depth

Cabinet width

Max permissible cabinet weightCabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left ndash read off value 3

Max cabinet weight 65 kg

Cladding thickness 2x 125 mm Knauf Cavity Dowel Hartmut

Max dowel load 60 kg

Required number of dowels 65 kg 60 kg = 108 2 dowels

are the min necessary

8

Fields of applicationTraverses are built-in elements in lightweight partitions that transfer the fastening loads directly into the grid or into the flanking solid constructions

Selection of the traverse and grid in dependence on the expected loadFastening Load max Load type Profile min Cladding thickness min Independent

furring possible

Knauf Boards DiamantkNm2 mm mm

Steel anchoring traversesee page 14

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes

Metal traverse with gypsum fibre insertsee page 12

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Multi-purpose traversesee page 10

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgKnauf Cavity Dowel Hartmut

fischer MHD 5 x 65 S

Knauf Multi- Purpose Screw FN 43 x 65

fischer plastic cavity dowels 8 x 50 with Knauf Multi-Purpose Screw FN 43 x 65

Wood screw Oslash 50 mm

Wood screw Oslash 60 mm

TraversesSteel anchoring traverse 75 ndash 45 40 45 45

Metal traversewith gypsum fibre insert

90 75 65 46 55 70

Multi-purpose traverse ndash ndash 125 ndash 115 165

Measuredwith300mmeccentricity

Loads on partitions and furringsAnchoring in the traverses

NotesStatic loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles

9

Loads on partitions and furringsAnchoring in the traverses

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 18 mm Knauf board acc to tableField of application static load max cantilever load 07 kNm (70 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Cabinet depth 500 mm cabinet width 800 mm Max cabinet weight 62 kg Fixing traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 45 kg

Required number of screws 62 kg 45 kg = 14 2 screws

are the min necessary

Metal stud partition W111de UA 75 cladding 15 mm Diamant GKFI acc to diagram

Field of application dynamic load max cantilever load 15 kNm (150 kgm) wall length

20

400

Cabinet depth100 200 600

Max permissible cabinet weight

140120

80

4060

kg

200

160

180

Cabinet width

mm

1000

1200

600

mm 300

100 800

240220

260280300320340

450400 500

165

1

23

Cabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left read off value 3

Max cabinet weight 165 kg

Multi-purpose traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 125 kg

Required number of screws 165 kg 125 kg = 13 2 screws

are the min necessary

10

Knauf multi-purpose traversesThe multi-purpose traverse is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards boilers folding wall attached seats folding handles and similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the floor-to-ceiling profilesThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FN

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Loads on partitions and furringsAnchoring in the traverses

Installation and applicationMulti-purpose traverse made of multi-layer wooden board and galvanized sheet metal profiles attached to the side of the CW studs UA profiles For CW studs screw fasten using the 6 enclosed Metal Screws LN 35 x 11 mm (3 per side) For UA profiles screw fasten with the 6 enclosed Drilling Screws ST 42 x 13 mm (3 per side)Arrangement in a rowUA profiles CW studs

Direction of installation Direction of installation

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 7: Fastening of Loads to Knauf Wall and Ceiling Systems

7

Loads on partitions and furringsAnchoring in the cladding

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 125 mm Diamant GKFI acc to tableField of application static load max cantilever load 04 kNm (40 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600

400 31 28 25 22 19 16

600 465 42 375 33 285 24

800 62 56 50 44 38 32

1000 775 70 625 55 475 40

1200 93 84 75 66 57 48

Cabinet depth 400 mm cabinet width 1000 mm Max cabinet weight 55 kg

Cladding thickness 125 mm plastic cavity dowel

Max dowel load 30 kg

Required number of dowels 55 kg 30 kg = 18 2 dowels

are the min necessary

Metal stud partition W111de CW 75 cladding 2x 125 mm Diamant GKFI acc to diagramField of application static load max cantilever load 07 kNm (70 kgm) wall length

400

mm12001000

600

100 200 400 500 600mm

10

70

60

40

20 30

kg

100

80 90

110120

800

300

50

1

23

450

65

Cabinet depth

Cabinet width

Max permissible cabinet weightCabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left ndash read off value 3

Max cabinet weight 65 kg

Cladding thickness 2x 125 mm Knauf Cavity Dowel Hartmut

Max dowel load 60 kg

Required number of dowels 65 kg 60 kg = 108 2 dowels

are the min necessary

8

Fields of applicationTraverses are built-in elements in lightweight partitions that transfer the fastening loads directly into the grid or into the flanking solid constructions

Selection of the traverse and grid in dependence on the expected loadFastening Load max Load type Profile min Cladding thickness min Independent

furring possible

Knauf Boards DiamantkNm2 mm mm

Steel anchoring traversesee page 14

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes

Metal traverse with gypsum fibre insertsee page 12

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Multi-purpose traversesee page 10

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgKnauf Cavity Dowel Hartmut

fischer MHD 5 x 65 S

Knauf Multi- Purpose Screw FN 43 x 65

fischer plastic cavity dowels 8 x 50 with Knauf Multi-Purpose Screw FN 43 x 65

Wood screw Oslash 50 mm

Wood screw Oslash 60 mm

TraversesSteel anchoring traverse 75 ndash 45 40 45 45

Metal traversewith gypsum fibre insert

90 75 65 46 55 70

Multi-purpose traverse ndash ndash 125 ndash 115 165

Measuredwith300mmeccentricity

Loads on partitions and furringsAnchoring in the traverses

NotesStatic loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles

9

Loads on partitions and furringsAnchoring in the traverses

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 18 mm Knauf board acc to tableField of application static load max cantilever load 07 kNm (70 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Cabinet depth 500 mm cabinet width 800 mm Max cabinet weight 62 kg Fixing traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 45 kg

Required number of screws 62 kg 45 kg = 14 2 screws

are the min necessary

Metal stud partition W111de UA 75 cladding 15 mm Diamant GKFI acc to diagram

Field of application dynamic load max cantilever load 15 kNm (150 kgm) wall length

20

400

Cabinet depth100 200 600

Max permissible cabinet weight

140120

80

4060

kg

200

160

180

Cabinet width

mm

1000

1200

600

mm 300

100 800

240220

260280300320340

450400 500

165

1

23

Cabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left read off value 3

Max cabinet weight 165 kg

Multi-purpose traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 125 kg

Required number of screws 165 kg 125 kg = 13 2 screws

are the min necessary

10

Knauf multi-purpose traversesThe multi-purpose traverse is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards boilers folding wall attached seats folding handles and similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the floor-to-ceiling profilesThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FN

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Loads on partitions and furringsAnchoring in the traverses

Installation and applicationMulti-purpose traverse made of multi-layer wooden board and galvanized sheet metal profiles attached to the side of the CW studs UA profiles For CW studs screw fasten using the 6 enclosed Metal Screws LN 35 x 11 mm (3 per side) For UA profiles screw fasten with the 6 enclosed Drilling Screws ST 42 x 13 mm (3 per side)Arrangement in a rowUA profiles CW studs

Direction of installation Direction of installation

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 8: Fastening of Loads to Knauf Wall and Ceiling Systems

8

Fields of applicationTraverses are built-in elements in lightweight partitions that transfer the fastening loads directly into the grid or into the flanking solid constructions

Selection of the traverse and grid in dependence on the expected loadFastening Load max Load type Profile min Cladding thickness min Independent

furring possible

Knauf Boards DiamantkNm2 mm mm

Steel anchoring traversesee page 14

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes

Metal traverse with gypsum fibre insertsee page 12

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Multi-purpose traversesee page 10

07 Static CW 50 125 125 No07 Static CW 50 18 15 Yes10 Static CW 75 125 125 No10 Static CW 50 18 15 Yes15 Static CW 50 18 15 No15 Static UA 50 18 15 Yes15 Dynamic UA 75 18 15 Yes

Fixing loadsFor fixing of cantilever loads

Dowel screw Maximum screw dowel load capacity in kgKnauf Cavity Dowel Hartmut

fischer MHD 5 x 65 S

Knauf Multi- Purpose Screw FN 43 x 65

fischer plastic cavity dowels 8 x 50 with Knauf Multi-Purpose Screw FN 43 x 65

Wood screw Oslash 50 mm

Wood screw Oslash 60 mm

TraversesSteel anchoring traverse 75 ndash 45 40 45 45

Metal traversewith gypsum fibre insert

90 75 65 46 55 70

Multi-purpose traverse ndash ndash 125 ndash 115 165

Measuredwith300mmeccentricity

Loads on partitions and furringsAnchoring in the traverses

NotesStatic loads in this respect are permanently fastened loads such as towel rails cabinets shelves and boilers Dynamic loads are exerted by fastened components which are subjected to continuous changes in load such as handrails fold-down seats and folding handles

9

Loads on partitions and furringsAnchoring in the traverses

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 18 mm Knauf board acc to tableField of application static load max cantilever load 07 kNm (70 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Cabinet depth 500 mm cabinet width 800 mm Max cabinet weight 62 kg Fixing traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 45 kg

Required number of screws 62 kg 45 kg = 14 2 screws

are the min necessary

Metal stud partition W111de UA 75 cladding 15 mm Diamant GKFI acc to diagram

Field of application dynamic load max cantilever load 15 kNm (150 kgm) wall length

20

400

Cabinet depth100 200 600

Max permissible cabinet weight

140120

80

4060

kg

200

160

180

Cabinet width

mm

1000

1200

600

mm 300

100 800

240220

260280300320340

450400 500

165

1

23

Cabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left read off value 3

Max cabinet weight 165 kg

Multi-purpose traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 125 kg

Required number of screws 165 kg 125 kg = 13 2 screws

are the min necessary

10

Knauf multi-purpose traversesThe multi-purpose traverse is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards boilers folding wall attached seats folding handles and similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the floor-to-ceiling profilesThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FN

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Loads on partitions and furringsAnchoring in the traverses

Installation and applicationMulti-purpose traverse made of multi-layer wooden board and galvanized sheet metal profiles attached to the side of the CW studs UA profiles For CW studs screw fasten using the 6 enclosed Metal Screws LN 35 x 11 mm (3 per side) For UA profiles screw fasten with the 6 enclosed Drilling Screws ST 42 x 13 mm (3 per side)Arrangement in a rowUA profiles CW studs

Direction of installation Direction of installation

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 9: Fastening of Loads to Knauf Wall and Ceiling Systems

9

Loads on partitions and furringsAnchoring in the traverses

RatingThe specified permissible cantilever loads are in accordance with the DIN 18183 or DIN 4103-1 at an eccentricity (spacing of resulting load to the wall surface) of max 300 mm The permissible load is reduced accordingly with greater eccentricity The determination of the permissible cantilever loads with divergent eccentricity is undertaken using the tables or diagrams on page 4 and page 5

Rating examples Determination of the permissible cabinet weight as well as the required minimum number of dowels (always ge 2)Metal stud partition W111de CW 50 cladding 18 mm Knauf board acc to tableField of application static load max cantilever load 07 kNm (70 kgm) wall length Cabinet

widthCabinet depthmm

mm 100 200 300 400 500 600400 43 40 37 34 31 28600 645 60 555 51 465 42800 86 80 74 68 62 561000 1075 100 925 85 775 701200 129 120 111 102 93 84

Cabinet depth 500 mm cabinet width 800 mm Max cabinet weight 62 kg Fixing traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 45 kg

Required number of screws 62 kg 45 kg = 14 2 screws

are the min necessary

Metal stud partition W111de UA 75 cladding 15 mm Diamant GKFI acc to diagram

Field of application dynamic load max cantilever load 15 kNm (150 kgm) wall length

20

400

Cabinet depth100 200 600

Max permissible cabinet weight

140120

80

4060

kg

200

160

180

Cabinet width

mm

1000

1200

600

mm 300

100 800

240220

260280300320340

450400 500

165

1

23

Cabinet depth 450 mm cabinet width 800 mm

With cabinet depth 450 mm 1 vertically upwards up to the cabinet width line 800 mm

2 at the intersection point horizontal to the left read off value 3

Max cabinet weight 165 kg

Multi-purpose traverse Knauf Multi-Purpose Screw FN 43 x 65

Max screw load 125 kg

Required number of screws 165 kg 125 kg = 13 2 screws

are the min necessary

10

Knauf multi-purpose traversesThe multi-purpose traverse is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards boilers folding wall attached seats folding handles and similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the floor-to-ceiling profilesThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FN

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Loads on partitions and furringsAnchoring in the traverses

Installation and applicationMulti-purpose traverse made of multi-layer wooden board and galvanized sheet metal profiles attached to the side of the CW studs UA profiles For CW studs screw fasten using the 6 enclosed Metal Screws LN 35 x 11 mm (3 per side) For UA profiles screw fasten with the 6 enclosed Drilling Screws ST 42 x 13 mm (3 per side)Arrangement in a rowUA profiles CW studs

Direction of installation Direction of installation

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 10: Fastening of Loads to Knauf Wall and Ceiling Systems

10

Knauf multi-purpose traversesThe multi-purpose traverse is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards boilers folding wall attached seats folding handles and similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the floor-to-ceiling profilesThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FN

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Loads on partitions and furringsAnchoring in the traverses

Installation and applicationMulti-purpose traverse made of multi-layer wooden board and galvanized sheet metal profiles attached to the side of the CW studs UA profiles For CW studs screw fasten using the 6 enclosed Metal Screws LN 35 x 11 mm (3 per side) For UA profiles screw fasten with the 6 enclosed Drilling Screws ST 42 x 13 mm (3 per side)Arrangement in a rowUA profiles CW studs

Direction of installation Direction of installation

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 11: Fastening of Loads to Knauf Wall and Ceiling Systems

11

Loads on partitions and furringsAnchoring in the traverses

W234de-A10 View ndash Design with UA profile W234de-A13 View ndash Design with CW stud

W234de-H10 Horizontal section ndash Design with UA profile W234de-H13 Horizontal section ndash Design with CW studeg W626de eg W626de

W234de-V10 Vertical section ndash Design with UA profile W234de-V13 Vertical section ndash Design with CW studeg W116de eg W112de

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

UA profile

Drillingscrew ST42 x 13(enclosed)

Wooden board 555

Stud spacing 625 (grid dimension)

300 Metal screw

LN 35 x 11(enclosed)

Multi-purpose traverse555 300 23 mm

Multi-layer wooden board

CW stud

Wooden board 555

Stud spacing 625 (grid dimension)

300

Multi-purpose traverse555 300 23 mm

UA profileDrilling screwST 42 x 13

Multi-purpose traverse555 300 23 mm

CW studMetal screwLN 35 x 11

48

eg folding wallattached seat

Knauf boardstrips

eg Supporthandle maxprojection 800 mm

Multi-purposetraverseUA profileKnauf boards

48

Multi-purposetraverseCW studKnauf boards

eg Cabinet

Scale 110 I Dimensions in mmDetails

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 12: Fastening of Loads to Knauf Wall and Ceiling Systems

12

Knauf steel anchoring traverse with gypsum fibre insertThe steel anchoring traverse with gypsum fibre insert is suitable for accepting loads attached to the wall up to 15 kNm wall length eg cupboards shelves handrails and similarThe metal traverse with gypsum fibre insert consists of 075 mm thick sheet metal as well as an 18 mm thick gypsum fibre board It is fastened to the side of the floor-to-ceiling profiles The attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNUse in partition systems where the requirement for non-combustible reaction to fire exists

Installation and applicationSteel anchoring traverse made of galvanized steel with gypsum fibre insert fastened to the CW studs UA profiles In case of CW studs crimp using a Stud Crimper and for UA profiles screw fasten with 6 Drilling screws LB 35 x 16 mmArrangement in a rowUA profiles CW studs

Loads on partitions and furringsAnchoring in the traverses

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 13: Fastening of Loads to Knauf Wall and Ceiling Systems

13

Scale 110 I Dimensions in mmDetailsW234de-A12 View - Design with UA profile W234de-A14 View - Design with CW stud

W234de-H12 Horizontal section - Design with UA profile W234de-H14 Horizontal section - Design with CW studeg W112de eg W112de

W234de-V12 Vertical section - Design with UA profile W234de-V14 Vertical section - Design with CW studeg W112de eg W112de

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Steel anchoring traversewith gypsum fibre insert

Traverse attached to UA profileusing drilling screws

UA profile

Steel anchoring traversewith gypsum fibre insert

CW stud

Crimp the traverse to the CW studusing a stud crimper

Traverse dimension 620

Stud spacing 625 (grid dimension)

290

Drilling screwLB 35 x 16

Steel anchoringtraverse with gypsum

fibre insert

UA profile Crimped Steel anchoring traversewith gypsum fibre insert

CW stud

eg Handrail

UA profileKnauf boards

Steel anchoring traversewith gypsum fibre insert

eg Handrail

CW studKnauf board

Steel anchoring traversewith gypsum fibre insert

Loads on partitions and furringsAnchoring in the traverses

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 14: Fastening of Loads to Knauf Wall and Ceiling Systems

14

Loads on partitions and furringsAnchoring in the traverses

Knauf steel anchoring traverseThe steel anchoring traverse is suitable for accepting loads attached to the wall up to 10 kNm wall length eg towel holders cupboards shelves and similar Not suitable for dynamic loads such as folding wall attached seatsThe steel anchoring traverse consists of 075 mm thick sheet metal and are crimped onto the side using a stud crimper on the CW studs Particularly suitable for single-layer clad metal stud partitions and furrings where in case of cantilever loads gt 04 kNm (400 kgm) wall length the installation of a traverse is required

NoteTraverses for installation in damp and wet rooms see also system data sheet W38de Knauf Metal Stud Partitions AQUAPANELreg

Installation and applicationCrimp the steel anchoring traverse made of galvanized sheet steel to the CW studs using a Stud CrimperAdditional screw fastening of the steel anchoring traverse via screw fastening of the cladding (min 2 to 3 anchoring points) Reduce the screw spacing of the cladding if necessaryArrangement in a rowCW studs

Scale 110 I Dimensions in mmDetailsW234de-A11 View W234de V11 Vertical section

eg W111de

W234de-H11 Horizontal sectioneg W111de

Sheet metal gauge 075 mm

Steel anchoring traverse

CW stud

Crimp the traverse to the CW studusing the stud crimper

290

Traverse dimension 620

Stud spacing 625 (grid dimension)

eg Cabinet

CW stud

Knauf boardSteel anchoring traverse

Steel anchoring traverseCW stud

Crimped

Note No web cutouts in the CW studs are permissible for traverses to which the CW studs are attached

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 15: Fastening of Loads to Knauf Wall and Ceiling Systems

15

Full-length SanistandFloor-to-ceiling Sanistands made of galvanized UA profiles (min UA 75) 2 mm thick are suitable for transferring loads from traverses into the supporting structure or for fixing loads hanging onto walls such as school blackboards up to 15 kNm wall lengthFloor-to-ceiling Sanistands profiles are anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cablesThe loads are connected directly to the flange of the UA profile

W228de-A10 View

le 1000 mm

UW runnercontinuous

Door frameconnection brackettop connection withenclosed dowels

CW studAxial spacing suitedto partition system

UA profileas afloor-to-ceilingSanistand forbearing cantileverloads

UW runnercontinuous

Door frameconnection bracketbottom connectionwith enclosed dowels

Scale 110

Installation and applicationFloor-to-ceiling Sanistands made of UA profiles must be anchored to the basic floor and ceiling with door frame brackets or connection brackets for UA profiles The upper door frame bracket includes openings for routing cables such as pipe-in-pipe systems or electrical cables Fasten objects to UA profiles using threaded rods U washers and M1012 steel nuts or self-tapping screws

Loads on partitions and furringsFull-length Sanistand

Detail

Notes

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsMaximum screw load with connections to full height Sanistand (UA profile)Every UA profile flange and anchoring point may not exceed a resulting pull-out load of 150 kN (150 kg)Components similar to cantilevers such as foldable rails should be screwed onto two adjacent UA profilesUse suitable drilling screws eg Ejot Zebra Piasta Hilti S-MD or comparable

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 16: Fastening of Loads to Knauf Wall and Ceiling Systems

16

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW116de-V1 Sanistand W116de-H1 SanistandVertical section I Without fire resistance Horizontal section I Without fire resistance

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connectionbracket with enclosedM8 carriage bolts

Knauf conection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Additional CW stud

Knauf sealing tape

Board strip installationacc to W11de systemdata sheet

Stud spacing le 625 mm

CW stud profile

Additional CW studBoard strip installation in acc with W11de system data sheet

Knauf connection bracket withenclosed M8 carriage bolts

Additional UA profileSanitand with concealedmount cistern

Notes

Max partition height UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 17: Fastening of Loads to Knauf Wall and Ceiling Systems

17

Loads on partitions and furringsFull-length Sanistand

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

Scale 110DetailsW626Vde-V1 Without back anchoring W626Vde-H1 Without back anchoring Vertical section Horizontal section

UW runnerUniflott + Trenn-Fix

UW runner

Additional UA profile

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connection bracket withenclosed M8 carriage bolt

2x 125 mm DiamantDiamant screw XTB

Knauf sealing tape

Sanistand withconcealed mount cisternKnauf connection bracket with

enclosed M8 carriage bolts

Stud spacing le 625 mm

UW runner

Knauf boardsCW stud

Additional UA profile

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 18: Fastening of Loads to Knauf Wall and Ceiling Systems

18

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V2 Back anchoring in traverse W626Vde-H2 Back anchoring in traverse Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile made of insulation strips

UW runner

UW runner

UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

Multi-purpose traverse 555 300 23 mm

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolt

Wall anchor installation acc to WCSanistand manufacturer specifications

Knauf sealing tape

Stud spacing le 625 mm

Multi-purpose traverse555 300 23 mm

UA profile

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Wall anchorinstallation acc to

WC Sanistandmanufacturerspecifications

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 19: Fastening of Loads to Knauf Wall and Ceiling Systems

19

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V3 Back anchoring in UA profile W626Vde-H3 Back anchoring in UA profile Vertical section Horizontal section

Sanistand withconcealed mount cistern

SealantUD profile on insulation strips

UW runner

UW runner

Additional UA profile

Knauf multi-purpose screw FN

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolts

2x 125 mm DiamantDiamant screw XTB

Knauf connection bracket withenclosed M8 carriage bolts

Fixing bolts with nuts andwashers

Knauf sealing tape

Stud spacing le 625 mm

Additional UA profile

UA profile Fixing bolts with nutsand washers

Knauf connection bracket withenclosed M8 carriage bolts

Knauf connectionbracket with enclosedM8 carriage bolts

Notes

Max partition height at rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partition for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 20: Fastening of Loads to Knauf Wall and Ceiling Systems

20

Loads on partitions and furringsFull-length Sanistand

Scale 110DetailsW626Vde-V4 Back anchoring in mounting rail W626Vde-H4 Back anchoring in mounting rail Vertical section Horizontal section

Sanistand withconcealed mount cistern

2x 125 mm Diamant

SealantUD profile on insulation strips

UW runner

Diamant screw XTB

UA profile

Knauf multi-purpose screw FN

Mounting rail with fixing screw

Knauf connection bracket withenclosed M8 carriage bolt

Uniflott + Trenn-Fix

UA profile

Knauf connection bracket withenclosed M8 carriage bolt

Knauf sealing tapeUW runner

Stud spacing le 625 mm

UA profile

UA profile

Mounting railFixing screw

Mounting screw

Sanistand withconcealed mount cistern

Knauf connection bracket withenclosed M8 carriage bolt

Knauf connectionbracket with enclosedM8 carriage bolt

Notes

Max partition height rear W112de UA 50 = 300 m UA 75 = see system data sheet W11de Knauf Metal Stud Partitions for the wall heights

Minimum cladding front wall installations ge 18 mm Knauf Boards recommendation 2x 125 mm Knauf Diamant

Web cutouts are not permissible in UA Sanistand subject to cantilever loads point loads or linear distributed loadsObserve the manufacturersrsquo details for lateral UA profiles and cladding Additional UA profiles are required laterally on Sanistand mounts acc to DIN 18340 section 374 Only possible without additional UA profiles if the manufacturer of the Sanistand base or WC Sanistand permits itDeviating specifications of the Sanistand manufacturer must be considered and observed

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 21: Fastening of Loads to Knauf Wall and Ceiling Systems

21

Notes

In case of load attachment to ldquomulti-level ceiling systemsrdquo refer to the respective valid Knauf system data sheetsIn case of attachment of loads to free-spanning ceilings see system data sheet D13de Knauf Free-Spanning Ceilings

Attachment of loads to Knauf board ceilingsAdditional loads eg lighting fixtures curtain rails and similar can be fixed to Knauf board ceilings using universal dowels cavity dowels spring toggle dowels or Knauf Hartmut Hohlraumduumlbel cavity dowelsAdditional loads must be considered when determining the load class

NoteHeavy loads must be attached directly on load-bearing building elements (basic ceiling) or on auxiliary constructions eg traverses

For each area under load of the Knauf board ceiling the weight of thefastened components may not exceed the following limits

Permissible weight per ceiling area in kgmsup2Without fire resistance With fire resistance1)

15 61)Incaseofapplicationasafireresistanceceilingwithexposedceiling(multi-levelceilingsystem)15kgmsup2totalweightispermissiblefortheexposedceiling(includinginsulationlayerandattachedloads)attachedtothefireresistanceceiling

Furthermore the following conditions applyFor each anchoring point the components fastened to the board ceiling may not exceed the following weights

Fastening method Permissible weight per anchoring point in kgWithout fire resistance With fire resistance

Fastening in the cladding 6 05

Fastening to the grid 10 10

Fastening in the claddingKnauf Hartmut Hohlraumduumlbel cavity dowelScrew M5

Fastening to the gridKnauf Universalschraube FN multi-purpose screw eg curtain rail

The minimum separation spacings between individual attached loads must be observed to avoid local overloading of the ceiling The minimum separation clearance between two attachment points consists of both load radii for the point loadsThe load radius of a point load can be taken from the following diagram in dependence on the permissible weight per unit area for additional loads

Point load in kg

7570656055504540353025201510

0 2 3 4 5 6 7 8 9 10

Radiu

s in c

m

1

50

Fastening in the claddingpossible (without fire resistance)

3 kgmsup2 permissible additional weight (on the exposed ceiling under a fire resistance ceiling refer to the respective valid Knauf system data sheets)6 kgmsup2 permissible additional weight (with fire resistance)15 kgmsup2 permissible additional weight (without fire resistance)

Example fastening scheme at 15 kgmsup2

05 kg

10 kg

3 kgr = 25 cm

r = 46 cm

6 kgr = 355 cm

1 kg

r = 15 cm

r = 105 cm

NoteThe anchored loads can be transferred using several anchoring elements

Loads on board ceilingsFastening in the cladding grid

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 22: Fastening of Loads to Knauf Wall and Ceiling Systems

22

Knauf multi-purpose traversesThe multi-purpose traverse in Knauf board ceilings is suitable for the application of point loads up to 075 kN eg chandeliers music speakers or similarThe multi-purpose traverse consists of a 23 mm thick multi-layer wooden board and galvanized sheet metal profiles It is fastened to the side of the CD furring channelThe attachment of the loads to the traverses should be performed using Knauf Multi-Purpose Screw FNInstallation is possible in a double layer profile grid and flush profile grid

Installation and applicationBend the Daisy chain clip before lateral screw fastening The Daisy chain clip is then Z shaped The unpunched metal side of the Daisy chain clip is pushed onto the lower side of the traverse and then screw fastened laterally through the factory-made hole on the long side of the traverse Screw fasten 4x Daisy chain clips each using one drywall screw TN 35 x 35 about 100 mm from the corner of the multi-layer board on the long edge of the multi-purpose traverse Arrange an additional CD channel (length ge 650 mm) for every long edge in accordance with the width of the multi-purpose traverse Alternately a ceiling furring channel can be used for application of the multi-purpose traverse The supporting profiles are suspended using ceiling suspenders of load class 40 kg The suspenders may not be situated in the direct vicinity of the longitudinal area of the traverse as this will hinder the installation of the traverse Introduce the multi-purpose traverse between the support profiles bend the Daisy chain clip around the CD channel and engage it In case of single-layer cladding do not screw fasten the surface cladding with the multi-purpose traverse

1 Apply the Daisy chain clip 2 Bend the Daisy chain clip 3 Screw fasten the Daisy chain clip

Loads on board ceilingsAnchoring in the traverses

100 mm

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 23: Fastening of Loads to Knauf Wall and Ceiling Systems

23

Loads on board ceilingsAnchoring in the traverses

Scale 110 I Dimensions in mmDetailsD112de SO18 Vertical section ndash Multi-purpose traverse D113de SO12 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO19 Vertical section ndash Multi-purpose traverse D113de SO13 Vertical section ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

D112de SO20 Top view ndash Multi-purpose traverse D113de SO14 Top view ndash Multi-purpose traverseeg with two additional CD channels I Without fire resistance eg with one additional CD channel I Without fire resistance

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Additional suspended load bearing capacity class ge 040 kNMulti-purposetraverse555 300 23 mm

300

Furring channel spacing 500

Additional CD channel with two suspendersLoad bearing capacity class ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Additional suspenderload bearing capacityclass ge 040 kN

Multi-purposetraverse555 300 23 mm

Fasten Daisy chain clip with drywall screwTN 35 x 35 to multi-purpose traverse

Wood panel 555approx

100

Daisy chain clip

Furring channel spacing 500

Traverse

CDchannel

Multi-layerwood panel

Furring channel spacing 500

Multi-purposetraverse

Daisy chain clip

Multi-layerwood panel

Additional grid 4 additional suspension points (eg Nonius suspension)

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses
Page 24: Fastening of Loads to Knauf Wall and Ceiling Systems

All technical changes reserved Only the current printed instructions are valid The stated information represents current state-of-the-art Knauf technology The entire state of approved engineering rules appropriate standards guidelines and rules of crafts-manship are not included herewith These and all application instructions have to be adhered to separately by the installer Our warranty is expressly limited to our products in flawless condition All application quantities and delivery amounts are based on empirical data that are not easily transferable to other deviating areasAll rights reserved All amendments reprints and photocopies including those of excerpts require our expressed permission

The stated constructional and structural design specifications and characteristics of building physics of Knauf systems can only be ensured with the exclusive use of Knauf system components or other products expressly recommended by Knauf

Knauf Gips KG Am Bahnhof 7 97346 Iphofen GermanyKnauf DirectTechnical Advisory Service

knauf-direktknaufde

wwwknaufde

VT03deeng09190TI

The iPad App Knauf Infothek now provides all the current information and documents from Knauf Gips KG at any time and in every location in a clear and comfortable wayKnauf Infothek

Videos for Knauf systems and products can be found under the following linkwwwyoutubecomknaufEPD

  • Usage instructions
    • Intended use of Knauf Systems
      • Loads on partitions and furrings
        • Introduction
        • Cantilever loads
          • Rating diagrams
            • Fastening in the cladding
              • Fields of application
              • Fixing loads
              • Rating
                • Anchoring in the traverses
                  • Fields of application
                  • Fixing loads
                  • Rating
                  • Knauf multi-purpose traverses
                  • Knauf steel anchoring traverse with gypsum fibre insert
                  • Knauf steel anchoring traverse
                    • Full-length Sanistand
                      • Loads on board ceilings
                        • Fastening in the cladding grid
                        • Anchoring in the traverses
                          • Knauf multi-purpose traverses