22
KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR BUILDING CONSTRUCTION

KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVERKIMMCO-ISOVER

SELECTION CRITERIA OF INSULATION FOR

BUILDING CONSTRUCTION

Page 2: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

SELECTION CRITERIA – MINERAL WOOL INSULATION

ACOUSTIC PERFORMANCE

1 / Selection Criteria - Doha

SUSTAINABILITY

FIRE PERFORMANCE

THERMAL PERFORMANCE

Page 3: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

2 / Selection Criteria

Page 4: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

SELECTION CRITERIA – MINERAL WOOL INSULATION

3 / Selection Criteria - Doha

THERMAL PERFORMANCE

Minimum Thickness

(condensation prevention)

K Value

(Energy Saving)

Page 5: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

THERMAL PERFORMANCE – MINIMUM THICKNESS

25 ºC

0.029

0.031

0.033

0.035

0.037

0.039

0.041

0.043

0.045

0.047

0.049

10 20 30 40 50 60 70 80 90 100 110 120

Ther

mal

Con

duct

ivit

y W

/m.ᵒ

k

Density Kg/mᵌ

10 ºC

25 ºC

4 / Selection Criteria

Lambda has always to be compared at the same temperature

In Europe Value measured at 10ºC, USA 24ºC & Japan 25 ºC

Optimum

Density

Range

R =k

t

Page 6: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

1. PAHW STANDARD HOUSE (WITHOUT ETICS)

2. + 12 CM MINERAL WOOL ETICS ON EXTERNAL WALLS + 6 CM MINERAL WOOL ON ROOF

3. + 6 CM MINERAL WOOL ETICS ON EXTERNAL WALLS + 6 CM MINERAL WOOL ON ROOF

ROOM TEMPERATURE

SETTING: 23 °C

MINERAL WOOL INSULATION - ENERGY SAVING

TOTAL EXTERNAL WALL: 456 M2

ROOF AREA: 234.5 M2

WINDOWS & DOORS: 50.7 M2

COLUMNS & BEAMS: 30%

4 / Selection Criteria - Doha

Page 7: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

MINERAL WOOL INSULATION - ENERGY SAVING

ETICS = EXTERNAL THERMAL INSULATION COMPOSITE SYSTEM

AACB

ADHISIVE MORTAR

INSULATION FASTNER

BASE MORTER WITH GLASS FIBER MESH

DECORATIVE COLORED RENDER

BASE BAR

MINERAL WOOL INSULATION BOARD

6 / Selection Criteria - Doha

Page 8: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

B1(reference)

B2(12 cm SW ETICS +

6 cm SW roof)

B3(6 cm SW ETICS +

6 cm SW roof)

Walls CB* Roof Walls CB Roof Walls CB Roof

U-Value(W/m2.°K)

0.58 2.52 0.31 0.21 0.29 0.21 0.31 0.53 0.21

Combined Walls(including door & windows)

R-value(h.ft2.°F/Btu)

6.51 18.31 22.3 27.58 14.2 27.58

* CB Columns and Beams.

Building

Element

MINERAL WOOL INSULATION - ENERGY SAVING

Page 9: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

THERMAL IMAGE ANALYSIS ON INTERNAL WALLS

MINERAL WOOL INSULATION - ENERGY SAVING

7 / Selection Criteria - Doha

Page 10: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

B2 WITH 12 CM STONE WOOL ETICS = 41% LESS COOLING DEMAND / PEAK POWER

B3 WITH 6 CM STONE WOOL ETICS = 31% LESS COOLING DEMAND / PEAK POWER

•0 1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 2 0 2 1 2 2 2 3

•4

•2

•6

• 3

•0

•5

•1

•B 1 (NO INSULATION)

•B2 ( 1 2 C M IN SU LA TIO N )

•B3 ( 6 CM INSULATIO N)

•AMBIENT DRY BULB TEMPERATURE

•40

•20

•30

•0

•50

•10

Time of the Day (hr)

MINERAL WOOL INSULATION - ENERGY SAVING

8 / Selection Criteria - Doha

Page 11: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

B2 WITH 12 CM MINERAL WOOL ETICS = 46.1% LESS ENERGY COOLING & ELECTRIC POWER

B3 WITH 6 CM MINERAL WOOL ETICS = 38.9% LESS ENERGY COOLING & ELECTRIC POWER

•60 80 100 120 140 160 180 200 220 240 260 280 300 320

•45

•40

•25

•20

•35

•30

•15

•10

•5

•0

•B2 (12 CM INSULATION)

•B3 (6 CM INSULATION)

Days of the year

MINERAL WOOL INSULATION - ENERGY SAVING

9 / Selection Criteria - Doha

Page 12: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

SELECTION CRITERIA – MINERAL WOOL INSULATION

10 / Selection Criteria - Doha

Smoke Emission

(smoke toxicity)

Reaction To Fire

(Flash Over)

FIRE PERFORMANCE

Droplets

(flammable particles)

Page 13: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

MINERAL WOOL INSULATION – FIRE PERFORMANCE

Fire Behaviour:

A1: No Flash Over

A2: No Flash Over

B : No Flash-over

C: Flash Over between 10 – 20 Minutes

D: Flash Over between 2 – 10 Minutes

E: Flash Over before 2 Minutes

Smoke emission : s1-s3

s1: Absent/weak smoke emission

S2: Medium smoke emission

s3: High smoke emission

Burning incandescent droplets :

d0: Absent/slow

d1: Medium

d2: High amount of droplets11 / Selection Criteria

Euro Class –(EN 13501)

Page 14: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER FIRE CLASSIFICATION – INSULATION MATERIAL

Source: Roxul

**

Ceramic fiber

12 / Selection Criteria - Doha

Page 15: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

MINERAL WOOL – FIRE COMPLIANCE TO (EN 13501)

13 / Selection Criteria

Mineral Wool only (LD)

A2,s1d0 Mineral Wool GW & SW (HD)

FIRE

SAFE

B,s1d0

C,s3d2 Polyolefin, PIR , PUR , PE

D,s3d3 EPS , XPS

A1,s1d0 Mineral Wool GW & SW (LD)

Faced Mineral Fiber + phenolic Foam

Page 16: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

SELECTION CRITERIA – MINERAL WOOL INSULATION

14 / Selection Criteria - Doha

SOUND ABSORPTION

(NRC)

SOUND TRANSISION

(STC)

ACOUSTIC PERFORMANCE

IMPACT SOUND

(IIC)

Page 17: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

MINERAL WOOL INSULATION – ACOUSTIC PERFORMANCE

5 / Selection Criteria

STC up to 70 dB NRC up to 1.05

Glasswool

Mineral

wool

Insulation

Mineral

wool

Insulation

Decorative

Finish

Concrete

IIC Up to 36

Page 18: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

SELECTION CRITERIA – MINERAL WOOL INSULATION

1 / Selection Criteria - Doha

ENERGY OPTIMIZATION

THERMAL COMFORT

sustainability

Low EMITTING MATERIAL

REGIONAL MATERIAL

Page 19: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

sand Recycled CulletFurnace

Mineral Wool

MINERAL WOOL - SUSTAINABILITY

FROM NATURE TO NATURE

NO STRATEGIC MATERIAL USED

UP TO 80% RECYCLED CONTENT

15 / Selection Criteria - Doha

Page 20: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

150 kWh/m²a

Equivalent to 15

m³ natural gas

or

15 L extra light oil

CO2 = 30 kg/m²a CO2 = 2 kg/m²a

15 kWh/m²a

Equivalent to

1.5 m³ natural gas

or

1.5 L extra light oil

U-value = 0.10

U-value = 0.10U-value = 0.22

U-value = 0.40

Re

duction

of h

ea

ting/c

oolin

ge

ne

rgy

5 / Selection Criteria

MINERAL WOOL - SUSTAINABILITY

Page 21: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER

SELECTION CRITERIA – MINERAL WOOL INSULATION

1 / Selection Criteria - Doha

Mineral Wool Contribute up to

27 point

according to LEED criteria

VOC ≤ 0.27 g/l

Page 22: KIMMCO-ISOVER SELECTION CRITERIA OF INSULATION FOR ...ashraeqatar.org/uploads/3/4/5/4/34547927/10_ashrae... · kimmco-isover b2 with 12 cm mineral wool etics = 46.1% less energy cooling

KIMMCO-ISOVER