4
GM Daewoo Confidential 1 C-100 HVAC MODULE EVA SENSOR Malfunction Feb .21. 2011 KDAC QUALITY CONTROL

KDAC QUALITY CONTROL

  • Upload
    afram

  • View
    36

  • Download
    0

Embed Size (px)

DESCRIPTION

KDAC QUALITY CONTROL. C-100 HVAC MODULE EVA SENSOR Malfunction. Feb .21. 2011. C-100 EVA SENSOR Malfunction. Frozen at A/C tube . 1. Problem definition . #1. #2. Vehicle: Winstorm Part name: EVA Sensor Description : Icing occurrence Occurrence&Date: WARRANTY (CKD @GM-UAE) - PowerPoint PPT Presentation

Citation preview

Page 1: KDAC QUALITY CONTROL

GM Daewoo Confidential 1

C-100 HVAC MODULE EVA SENSOR Malfunction

Feb .21. 2011KDAC QUALITY CONTROL

Page 2: KDAC QUALITY CONTROL

GM Daewoo Confidential 2

1. Problem definition Vehicle: Winstorm Part name: EVA Sensor Description : Icing occurrence Occurrence&Date: WARRANTY (CKD @GM-UAE) Quantities : 2pcs (2/9, received)

# Part Name Part LOT VIN No. Build

DateFound Date

Mileage (Km)

1 EVA Sensor ’09-12/1 KLIFC6BGOAB027405 2010/2/03 - 6,955

2 EVA Sensor ’09-12/1 KLIFC6BG1AB026859 2010/1/27 - 11,585

#2#1

Vehicle information

Frozen at A/C tube

C-100 EVA SENSOR Malfunction

Page 3: KDAC QUALITY CONTROL

GM Daewoo Confidential 3

Basic performance test (Resistance value check @ 0 ,25 ,50 )

C-100 EVA SENSOR Malfunction

Photo Comment

SpecR@0 R@25 R@50

6.65+/-5%(kΩ) 2.0+/-10%(kΩ) -

#16.480 1.9974 0.705 OK

Resistor value OK 0 ,25 ,50

#26. 471 1.9810 0.691 OK

Resistor value OK 0 ,25 ,50

2. Returned part analysis

Page 4: KDAC QUALITY CONTROL

GM Daewoo Confidential 4

X-Ray Analysis (#1)

C-100 EVA SENSOR Malfunction

① Thermistor chip: OK ② Wire soldering: OK

2. Returned part analysis

Terminal & Wire : OK

X-Ray Analysis (#2)

① Thermistor Chip: OK ② Wire soldering: OK

Terminal & Wire : OK

3. Conclusion No Trouble Found (Resistance value OK , X-Ray OK)