Upload
afram
View
36
Download
0
Embed Size (px)
DESCRIPTION
KDAC QUALITY CONTROL. C-100 HVAC MODULE EVA SENSOR Malfunction. Feb .21. 2011. C-100 EVA SENSOR Malfunction. Frozen at A/C tube . 1. Problem definition . #1. #2. Vehicle: Winstorm Part name: EVA Sensor Description : Icing occurrence Occurrence&Date: WARRANTY (CKD @GM-UAE) - PowerPoint PPT Presentation
Citation preview
GM Daewoo Confidential 1
C-100 HVAC MODULE EVA SENSOR Malfunction
Feb .21. 2011KDAC QUALITY CONTROL
GM Daewoo Confidential 2
1. Problem definition Vehicle: Winstorm Part name: EVA Sensor Description : Icing occurrence Occurrence&Date: WARRANTY (CKD @GM-UAE) Quantities : 2pcs (2/9, received)
# Part Name Part LOT VIN No. Build
DateFound Date
Mileage (Km)
1 EVA Sensor ’09-12/1 KLIFC6BGOAB027405 2010/2/03 - 6,955
2 EVA Sensor ’09-12/1 KLIFC6BG1AB026859 2010/1/27 - 11,585
#2#1
Vehicle information
Frozen at A/C tube
C-100 EVA SENSOR Malfunction
GM Daewoo Confidential 3
Basic performance test (Resistance value check @ 0 ,25 ,50 )
C-100 EVA SENSOR Malfunction
Photo Comment
SpecR@0 R@25 R@50
6.65+/-5%(kΩ) 2.0+/-10%(kΩ) -
#16.480 1.9974 0.705 OK
Resistor value OK 0 ,25 ,50
#26. 471 1.9810 0.691 OK
Resistor value OK 0 ,25 ,50
2. Returned part analysis
GM Daewoo Confidential 4
X-Ray Analysis (#1)
C-100 EVA SENSOR Malfunction
① Thermistor chip: OK ② Wire soldering: OK
2. Returned part analysis
Terminal & Wire : OK
①
②
X-Ray Analysis (#2)
① Thermistor Chip: OK ② Wire soldering: OK
①
②
Terminal & Wire : OK
3. Conclusion No Trouble Found (Resistance value OK , X-Ray OK)