Upload
intermountainwater
View
225
Download
0
Embed Size (px)
Citation preview
7/29/2019 IWP Installation - startup - disinfection procedures.pdf
http://slidepdf.com/reader/full/iwp-installation-startup-disinfection-procedurespdf 1/5
Water Softener
Installation And Startup
Checklist
Clear the
installation area &
sweep the floor
where the system
will be installed
Remote Brine
Tank?
· Install remote brine tank within 40 feet of system
· Install Pur-Gard feeder at system
· Sweep area carefully before installing brine tank
Is household
pressure 50-75psi
static
Is there adequate
thermal expansion
protection ?
YES
NO
NO
Connect to
household
plumbing
according to code
Install Leak
Controller
& Drip Tray
Install Safety
overflow on Brine
Tank
CALL TECH-SUPPORT
1-800-454-3429
Install 3/8" Pex
drain (½” OD)
using appropria
air-gap up to 100
Install ¼” OD
polytube to float
and Pur-Gard
reservoir
Install surge
protector or UPS
Backup
Bypass System
Run bathtub cold
to purge debris
and flux from
piping. Leave tub
running
Bring system
online slowly, the
return to tub
& observe wate
Run water until
clear, then turn off
tub
IS THERE RESIN IN
THE WATER ?
YES
NO
Plug system in
&
Check for leaks
Program according
to system manual
IS THE SCREEN
BLANK ?
YES
NO
Test water
at tub
PASSED
TESTS?
NO
YES IS WATER SOFT?
NO
INSTALLATION &
STARTUP IS COMPLET
Perform Startup
Tests
Register Warran1-800-454-3429
Customer Name
Customer email
Customer Address
Customer Phone
System Serial No.
Pur-Gard
DirectInjection
This is an unsafe condition
DO NOT CONTINUE INSTALLATION
CALL TECH-SUPPORT
1-800-454-3429
Shut off
Main Water Supply
Turn on
Main Water Supply
7/29/2019 IWP Installation - startup - disinfection procedures.pdf
http://slidepdf.com/reader/full/iwp-installation-startup-disinfection-procedurespdf 2/5
Water Softener
Installation And Startup
Checklist
Clear the
installation area &
sweep the floor
where the system
will be installed
Remote Brine
Tank?
· Install remote brine tank within 40 feet of system
· Sweep area carefully before installing brine tank
Is household
pressure 50-75psi
static
This is an unsafe condition
DO NOT CONTINUE INSTALLATION
CALL TECH-SUPPORT
1-800-454-3429
Is there adequate
thermal expansion
protection ?
YES
NO
NO
Connect to
household
plumbing
according to code
Install Leak
Controller
& Drip Tray
Install Safety
overflow on Brine
Tank
CALL TECH-SUPPORT
1-800-454-3429
Install 3/8" Pex
drain (½” OD)
using appropriate
air-gap up to 100ft
Install surge
protector or UPS
Backup
Bypass System
Run bathtub cold
to purge debris
and flux from
piping. Leave tub
running
Bring system
online slowly, then
return to tub
& observe water
Run water until
clear, then turn off
tub
IS THERE RESIN IN
THE WATER ?
YES
NO
Plug system in
&
Check for Leaks
Program according
to system manual
IS THE SCREEN
BLANK ?
YES
NO
Test water
at tub
PASSED
TESTS?
NO
YES IS WATER SOFT?
NO
INSTALLATION &
STARTUP IS COMPLET
Perform Startup
Tests
Register Warran1-800-454-3429
Customer Name
Customer email
Customer Address
Customer Phone
System Serial No.
Pur-Gard
Drip Feeder
Shut off
Main Water Supply
Turn on
Main Water Supply
7/29/2019 IWP Installation - startup - disinfection procedures.pdf
http://slidepdf.com/reader/full/iwp-installation-startup-disinfection-procedurespdf 3/5
UltraClean
Installation & Startup
Procedure
Clear the
installation area &
sweep the floor
where the system
will be installed
Existing Softener Install UltraClean Upstream of softener
Is household
pressure 40-75psi
static
This is an unsafe condition
DO NOT CONTINUE INSTALLATION
CALL TECH-SUPPORT
1-800-454-3429
Is there adequate
thermal expansion
protection ?
YES
NO
NO
Connect to household plumbing according to code.
Install system on the DOWNFLOW INLET port
Install Leak
Controller
& Drip Tray
CALL TECH-SUPPORT
1-800-454-3429
Bypass UltraClean
and all
downstream
treatment
equipment
Run bathtub cold
to purge debris &
flux from piping.
Leave tub running
(5 minutes)
Bring system
online slowly and
check for leaks,
then return to tub
& observe water
Run water until
clear, then turn off
tub
(10 Minutes)
IS THERE GRANULAR
CARBON IN THE
WATER ?
YES
NO
INSTALLATION &
STARTUP IS COMPLETE
Register Warranty1-800-454-3429
Customer Name
Customer emailCustomer Address
Customer Phone
System Serial No.
Version 1.0
Bring downstream
equipment online
slowly, and check
for leaks
Shut off
Main Water Supply
Turn on
Main Water Supply
7/29/2019 IWP Installation - startup - disinfection procedures.pdf
http://slidepdf.com/reader/full/iwp-installation-startup-disinfection-procedurespdf 4/5
ScaleStop
Installation & Startup
Procedure
Clear the
installation area &
sweep the floor
where the system
will be installed
Existing SystemInstall ScaleStop Downstream of softener or other Point
of Entry treatment equipment
Is household
pressure 40-75psi
static
This is an unsafe condition
DO NOT CONTINUE INSTALLATION
CALL TECH-SUPPORT
1-800-454-3429
Is there adequate
thermal expansion
protection ?
YES
NO
NO
Connect to household plumbing according to code.
Install system on the UPFLOW INLET port
Install Leak
Controller
& Drip Tray
CALL TECH-SUPPORT
1-800-454-3429
Bypass System
Run bathtub cold
to purge debris &
flux from piping.
Leave tub running
(5 minutes)
Bring system
online slowly and
check for leaks,
then return to tub
& observe water
Run water until
clear, then turn off
tub
(5 Minutes)
IS THERE RESIN IN
THE WATER ?
YES
NO
INSTALLATION &
STARTUP IS COMPLETE
Register Warranty1-800-454-3429
Customer Name
Customer emailCustomer Address
Customer Phone
System Serial No.
Version 1.0
Shut off
Main Water Supply
Turn on
Main Water Supply
7/29/2019 IWP Installation - startup - disinfection procedures.pdf
http://slidepdf.com/reader/full/iwp-installation-startup-disinfection-procedurespdf 5/5
Periodic Maintenance and Disinfection Procedure
Residential Water Softeners SP-5000
Compliant
Protocol
Water Testing
· Raw Water
· Soft Cold
· Soft Hot
DOCUMENT
· Hardness
· Iron
· TDS
· pH
Gather Data
· Family Size
· Concerns
Test Operation
and Flowmete
Check Brine Tank
· Float
· Overflow
Tubing
Add disinfectant to
system
DOCUMENT
· Water Pressure
· Functionality status
www.sp-5000.com www.softwateradvice.com
DOCUMENT
· Functionality Problems
· Bacterial Contamination
10 minutes contact
time
Flush system
(4 Bed Volumes)
Bypass System
Test Soft Cold
Hardness
TDS
Place system into
a brine/rinse cycle
Draw brine for 10
minutes
Terminate
regeneration cycle
Update system
software/
programming
Bring system
online
DOCUMENT
· Hardness
· TDS
Report information to customer
Present upgrade and system enhancement options
Renew Periodic Maintenance Contract
50 75 100 125 150 175 200 225 250 275 300 325 350 375 40
1 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
3 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
5 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
7 12 12 12 12 12 12 12 12 12 12 12 12 12 12 12
10 12 12 12 12 12 12 12 12 12 12 12 11 11 10 9
14 12 12 12 12 12 12 12 12 12 11 10 9 9 8 8
18 12 12 12 12 12 12 12 11 10 9 9 8 7 7 6
23 12 12 12 12 12 12 11 10 9 8 7 7 6 6 6
27 12 12 12 12 12 11 10 9 8 7 7 6 6 5 5
32 12 12 12 12 11 10 8 7 7 6 6 5 5 4 4
35 12 12 12 12 10 8 7 6 6 5 5 4 4 4 4
Gallons Per Day
G r a i n s P e r G a l l o n
Every x Months Periodic Maintenance Should Be Done
Chlorine Level Mi Minimum Annual Resin
Performance Loss
0.1 ppm # 1 %
0.2 ppm # 2 %
0.5 ppm # 5 %
0.7 ppm # 7 %
1 ppm # 10 %
1.25 ppm 8 12.5 %
1.5 ppm 7 15 %
2 ppm 5 20 %
2.5 ppm 4 25 %
3 ppm 3 30 %