DATE OF ISSUE: SCALE: DRAWN: REVISION DATE DESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan 01.05.19 MB Project Number: 1922 Drawing Number: A1 B 08.05.19 14.07.19 Preliminary Issue for Client Comments Issued for consultants and building approval PO Box 2655, Malaga WA 6944 GENERAL NOTES: - DO NOT SCALE FROM DRAWINGS. - THESE PLANS ARE THE SOLE PROPERTY OF DESIGNER AND MAY NOT BE REPRODUCED OR MODIFIED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION. - CONTRACTORS TO CHECK ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO THE COMMENCEMENT OF ANY WORKS AND ANY DISCREPANCIES TO BE BROUGHT TO THE ATTENTION OF THE SUPERVISOR. © COPYRIGHT STATEMENT THIS DESIGN AND / OR DRAWING IS CONFIDENTIAL AND SHALL REMAIN THE PROPERTY OF QUALITY DESIGN SOLUTIONS PTY LTD. IT MUST NOT BE REPRODUCED, COPIED OR ALTERED WITHOUT THE APPROVAL OF QUALITY DESIGN SOLUTIONS PTY LTD. 1:250 (A1) ISSUED FOR BUILDING APPROVAL A C 04.08.19 Loading dock roof and electrical amendments D xx.xx.xx - Email: [email protected] Mobile: 0403 165 270 BOTTOM OF BANK EXISTING WAREHOUSE CONCRETE COMMERCIAL BUILDING POSTS COMMERCIAL BUILDING CONCRETE COMMERCIAL BUILDING BOLLARDS BOLLARDS EXISTING INSPECTION PIPE TO BE REMOVED CONCRETE EDGE OF CONCRETE CONCRETE CROSSOVER EDGE OF EXISTING CONCRETE DOME POWERPOLE POWERPOLE EDGE OF GRAVEL PORTION OF WIRE FENCE TO BE REMOVED METAL FENCE COLORBOND FENCE METAL FENCE STEEL FENCE RENDERED WALL SEGMENTS WV POOLING WATER WATER VALVE GASVALVE PIT DEPTH 2.2 DIA 1.8 PIT DEPTH 2.03 DIA 1.8 PIT DEPTH 1.9 DIA 1.8 PIT DEPTH 2.1 DIA 1.8 PIT DEPTH 1.76 DIA 1.8 PIT DEPTH 1.95 DIA 1.8 PIT DEPTH 2.14 DIA 1.8 PIT DEPTH 2.07 DIA 1.8 PIT DEPTH 1.9 DIA 1.8 PIT DEPTH 1.82 DIA 1.8 PIT DEPTH 1.74 DIA 1.8 PIT DEPTH 1.81 DIA 1.8 KERB KERB KERB KERB KERB KERB KERB KERB METAL MANHOLE METAL MANHOLE METAL MANHOLES MANHOLES PIPE PIPES DESTINATION NOT KNOWN DRAINAGE PIT PIPES UNMEASURABLE INV 18.3DIA 0.15 INV 18.25DIA 0.15 INV 18.24DIA 0.15 INV 18.25DIA 0.15 INV 18.28DIA 0.15 INV 18.24DIA 0.15 INV 18.19DIA 0.15 INV 18.24DIA 0.15 INV 18.38DIA 0.15 INV 18.28DIA 0.15 INV 18.28DIA 0.15 INV 18.26DIA 0.15 INV 18.28DIA 0.15 INV 18.26DIA 0.15 INV 18.29DIA 0.15 INV 18.32DIA 0.15 PINV 18.27D 0.15 INV 18.3DIA 0.15 INV 18.26DIA 0.15 INV 18.31DIA 0.15 INV 18.27DIA 0.15 INV 18.28DIA 0.15 INV 18.27DIA 0.15 INV 18.26DIA 0.15 INV 18.33DIA 0.15 INV 18.26DIA 0.15 INV 18.31DIA 0.15 INV 18.3DIA 0.15 INV 18.29DIA 0.15 INV 18.21DIA 0.15 INV 18.27DIA 0.15 INV 18.24DIA 0.15 INV 18.24DA 0.15 INV 18.29DIA 0.15 INV 18.27DIA 0.15 INV 18.23DIA 0.15 INV 18.27DIA 0.15 INV 18.26DIA 0.15 INV 18.31DIA 0.15 INV 18.23DIA 0.15 INV 18.27DIA 0.15 INV 18.19DIA 0.15 INV 18.13DIA 0.15 INV 18.18DIA 0.15 WATER TANK PUMP SHED WATER TANK WATER TANK TOP OF BANK TOP OF BANK TELSTRA PIT CONCRETE WALL CONCRETE WALL BRICK WALL CONCRETE WALL CONCRETE WALL WATER METER WV WV WV VALVE 89°49'40" 90°1'50" 89°58'10" 90°10'20" 43.5 168.16 43.5 168.26 7317 m² LOT 32 CASINO STREET D 69416 LOT 23 D 97259 LOT 31 D 19464 LOT 10 D 19464 LOT 7 D 19464 LOT 8 D 19464 LOT 9 SEA CONTAINER SEA CONTAINERS LARGE METAL OVERHANG LARGE METAL OVERHANG SECOND STOREY BALCONY FIRE HYDRANT BOOSTER TWIN HEAD FIRE HYDRANT DATUM_NAILIN BITUMENRL 18.75 SEPTIC PUMP 19.08 19.07 FFL 19.19 FFL 19.18 FFL 19.19 FFL 19.18 FFL 19.21 FFL 19.19 FFL19.21 19.23 18.90 18.92 18.94 19.27 19.16 19.18 19.19 19.30 19.29 19.15 19.02 19.11 19.15 19.22 19.10 19.10 19.08 19.09 19.09 19.10 19.00 18.99 18.99 19.00 19.11 19.09 19.17 19.12 19.12 19.14 19.22 19.14 19.13 19.16 19.12 19.14 19.15 19.06 19.07 19.10 19.06 19.25 19.18 19.15 19.14 19.12 19.15 18.84 18.82 18.84 19.02 19.05 18.92 19.18 19.09 19.17 19.18 19.19 19.09 19.03 19.07 19.07 19.07 19.09 19.00 19.01 18.97 18.97 18.96 18.97 18.93 18.91 18.96 19.11 19.09 19.04 19.22 19.13 19.05 19.02 19.02 18.99 18.98 18.93 19.13 19.06 19.12 19.08 19.11 19.08 18.98 18.97 19.15 18.93 18.96 19.02 19.17 19.09 19.09 18.96 19.04 19.07 19.11 19.12 19.03 19.17 19.18 19.06 19.12 19.10 19.14 19.11 19.15 19.08 19.08 19.16 19.11 19.06 19.10 19.09 19.07 19.09 19.03 19.09 19.06 19.06 18.89 18.92 18.91 18.88 18.87 18.95 18.94 18.95 18.98 18.96 18.94 18.98 19.11 19.06 18.88 18.89 18.95 18.94 18.97 18.98 18.97 18.96 18.98 18.99 18.96 18.95 18.98 18.99 18.98 18.99 18.98 18.90 18.89 18.85 18.85 18.89 18.90 18.77 18.71 18.73 18.74 19.19 19.07 19.06 19.08 19.16 19.19 19.05 19.02 19.00 19.01 19.08 19.16 19.00 18.98 18.97 18.96 18.97 18.97 19.01 18.99 19.00 18.90 18.90 18.88 18.90 18.89 18.91 19.02 19.00 18.98 19.03 19.01 19.04 19.03 19.05 19.02 19.06 19.02 19.02 19.05 18.94 18.97 18.99 19.04 19.15 19.05 19.04 19.04 19.03 19.05 18.75 18.71 18.83 18.88 18.92 18.85 18.96 18.97 18.94 18.89 18.98 18.90 18.90 18.94 19.14 19.12 19.11 19.13 19.04 18.93 18.95 18.93 19.00 18.94 19.00 18.99 18.96 19.02 19.04 19.00 18.98 18.94 18.94 19.00 19.00 18.95 18.94 18.94 18.97 18.77 18.90 18.94 18.96 18.95 19.01 19.11 19.21 19.18 19.13 19.05 19.01 19.05 19.01 18.96 18.97 18.93 19.15 19.02 19.01 18.99 19.12 19.16 19.17 19.19 19.18 19.17 19.19 19.19 19.19 19.18 19.19 19.18 19.17 19.17 19.17 19.16 19.08 19.16 19.17 19.15 19.23 19.18 19.16 19.15 19.03 18.89 18.89 18.89 18.90 18.88 18.88 18.88 18.86 18.87 19.20 19.08 18.98 18.96 18.90 18.99 18.84 18.75 18.46 18.53 18.54 18.40 18.59 18.48 18.43 18.66 18.61 18.61 18.54 18.62 18.71 19.05 19.03 19.13 19.06 19.05 19.06 19.08 18.95 19.04 18.88 18.98 19.08 19.13 19.07 19.01 19.09 19.10 19.03 19.00 19.06 19.09 19.13 19.17 19.02 18.97 18.94 19.09 19.09 19.08 19.09 19.17 19.02 18.68 18.68 18.68 18.72 19.06 18.98 18.99 18.98 18.99 18.99 18.99 18.99 19.03 19.06 19.17 19.07 19.06 19.17 19.21 19.26 19.02 19.00 19.10 18.98 18.98 19.11 19.19 19.17 19.11 19.12 19.15 19.10 19.13 19.17 19.11 19.20 19.04 19.04 19.03 19.03 18.78 18.86 18.83 19.07 18.90 18.89 18.89 18.90 18.60 18.63 18.56 18.64 19.18 19.16 19.16 19.15 19.16 18.92 18.91 18.55 18.61 18.63 18.76 18.76 18.87 18.77 18.89 18.88 18.93 18.96 18.96 19.06 19.16 19.16 19.14 19.16 19.16 19.17 19.14 19.11 19.16 19.01 18.96 19.03 19.04 19.14 19.06 18.89 19.00 19.04 19.02 19.02 19.00 19.09 19.03 19.02 19.06 19.12 19.02 19.02 18.76 18.65 19.06 18.99 19.08 19.09 19.07 19.08 19.00 19.00 19.00 19.00 19.00 19.00 19.00 19.00 19.00 19.00 19.00 19.00 19.00 19.00 19.00 19.00 18.70 18.80 18.80 18.90 18.90 18.90 18.90 18.90 18.90 19.10 19.10 19.10 19.10 19.10 19.10 19.10 19.10 19.10 19.10 19.10 19.10 19.10 PORTION OF COLORBOND FENCE TO BE REMOVED WIRE FENCE 18.97 COLORBOND FENCE APPROX. 18.35 TO NEIGHBOURS FOOTING APPROX. 17.83 TO NEIGHBOURS FOOTING APPROX. 18.36 TO NEIGHBOURS FOOTING EXISTING INSPECTION PIPE TO BE REMOVED EXISTING OFFICE NORTH SU M M E R S U N S U N W I T N E R H O T D R Y W I ND S P R EV AI L I N G WI N D & RA I N ALL CONTRACTORS WORKING ON THIS PROJECT TO CHECK ALL DIMENSIONS AND NOTES PRIOR TO INITIATING ANY WORKS. ALL DISCREPANCIES TO BE NOTIFIED TO THE PROJECT MANAGER STRAIGHT AWAY. NOTES: - DO NOT SCALE FROM THE SITE SURVEY PLAN. - THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATIONS, REPORTS, CONTRACTS AND DRAWINGS. - ALL DIMENSIONS TAKEN TO STRUCTURAL SURFACES UNLESS OTHERWISE NOTED (STUD FRAMING / CONCRETE PANELS).

ISSUED FOR BUILDING APPROVAL · DATE OF ISSUE: SCALE: DRAWN: REVISDIAOTNEDESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ISSUED FOR BUILDING APPROVAL · DATE OF ISSUE: SCALE: DRAWN: REVISDIAOTNEDESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan

DATE OF ISSUE:

SCALE:

DRAWN:

REVISION DATE DESCRIPTION

Lot 32 #18 Casino Street Welshpool

Client:

Project Title:

Alita Constructions

Site Survey Plan01.05.19

MB

Project Number:

1922Drawing Number:

A1

B

08.05.19

14.07.19

Preliminary Issue for Client Comments

Issued for consultants and building approval

PO Box 2655, Malaga WA 6944

GENERAL NOTES:- DO NOT SCALE FROM DRAWINGS.- THESE PLANS ARE THE SOLE PROPERTY OF DESIGNER AND MAY NOT BEREPRODUCED OR MODIFIED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION.- CONTRACTORS TO CHECK ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO THECOMMENCEMENT OF ANY WORKS AND ANY DISCREPANCIES TO BE BROUGHT TO THEATTENTION OF THE SUPERVISOR.

© COPYRIGHT STATEMENTTHIS DESIGN AND / OR DRAWING IS CONFIDENTIAL AND SHALL REMAIN THE PROPERTYOF QUALITY DESIGN SOLUTIONS PTY LTD. IT MUST NOT BE REPRODUCED, COPIED ORALTERED WITHOUT THE APPROVAL OF QUALITY DESIGN SOLUTIONS PTY LTD.

1:250 (A1)

ISSUED FOR BUILDING APPROVAL

A

C 04.08.19 Loading dock roof and electrical amendments

D xx.xx.xx -

Email: [email protected] Mobile: 0403 165 270

BOTTOMOF BANK

EXISTING WAREHOUSE

CONCRETE COMMERCIAL BUILDING

PO

STS

COMMERCIALBUILDING

CONCRETECOMMERCIALBUILDING

BOLLARDS

BOLLARDSEXISTING INSPECTION PIPE TO BE REMOVED

CONCRETE

ED

GE

OF

CO

NC

RE

TE

CO

NC

RE

TEC

RO

SS

OV

ER

ED

GE

OF

EX

ISTI

NG

CO

NC

RE

TE

DOME POWERPOLE

POWERPOLE

ED

GE

OF G

RAV

EL

PORTION OF WIRE FENCE TO BE REMOVED

METAL FENCE

COLORBONDFENCE

METAL FENCE

STE

EL FE

NC

E R

EN

DE

RE

DW

ALL S

EG

ME

NTS

WV

POOLINGWATER

WATERVALVE

GASVALVE

PIT DEPTH2.2 DIA 1.8

PIT DEPTH2.03 DIA 1.8

PIT DEPTH1.9 DIA 1.8

PIT DEPTH2.1 DIA 1.8

PIT DEPTH1.76 DIA 1.8

PIT DEPTH1.95 DIA 1.8

PIT DEPTH2.14 DIA 1.8

PIT DEPTH2.07 DIA 1.8

PIT DEPTH1.9 DIA 1.8

PIT DEPTH1.82 DIA 1.8

PIT DEPTH1.74 DIA 1.8

PIT DEPTH1.81 DIA 1.8 K

ER

B

KERB

KE

RB

KERBKERB

KE

RB

KE

RB

KE

RB

METALMANHOLE

METALMANHOLE

METALMANHOLES MANHOLES

PIPE

PIPES DESTINATIONNOT KNOWN

DRAINAGE PIT PIPESUNMEASURABLE

INV 18.3DIA0.15

INV

18.25DIA

0.15

INV 18.24DIA

0.15

INV 18.25DIA0.15

INV

18.28DIA

0.15

INV 18.24DIA0.15

INV

18.19DIA

0.15IN

V 18.24D

IA0.15

INV

18.38DIA

0.15

INV 18.28DIA0.15

INV 18.28DIA0.15

INV 18.26DIA0.15

INV 18.28DIA

0.15

INV 18.26DIA

0.15

INV 18.29DIA0.15 INV 18.32DIA

0.15

PIN

V 18.27D

0.15 INV 18.3DIA

0.15

INV 18.26DIA0.15

INV 18.31DIA0.15

INV 18.27DIA

0.15

INV

18.2

8DIA

0.15

INV 18

.27DIA

0.15

INV 18.26DIA0.15

INV 18.33DIA0.15

INV 18.26DIA

0.15 INV

18.3

1DIA

0.15

INV 18

.3DIA

0.15

INV 18.29DIA0.15

INV 18.21DIA0.15

INV 18.27D

IA

0.15 INV 18.24DIA

0.15

INV 18.24DA

0.15

INV 18.29D

IA

0.15

INV 18.27D

IA0.15

INV 18.23DIA

0.15

INV 18.27DIA0.15

INV 18.26DIA0.15

INV

18.31DIA

0.15

INV 18.23DIA

0.15

INV

18.27DIA

0.15IN

V 18.19D

IA0.15

INV 18.13DIA0.15

INV

18.18DIA

0.15

WATER TANKPUMP SHED

WATERTANK

WATER TANK

TOP O

F BA

NK

TOP O

F BA

NK

TELSTRA PIT

CO

NC

RE

TE W

ALL

CONCRETE WALL

BR

ICK

WA

LLC

ON

CR

ETE

WA

LL

CONCRETE WALL

WATERMETER

WV

WV WV

VALVE

89°49'40" 90°1'

50"

89°58'10"90°10'20"

43.

5

168.16

43.5

168.26

7317 m²LOT 32

CA

SIN

O

STR

EE

T

D 69416

LOT 23

D 97259LOT 31

D 19464LOT 10

D 19464LOT 7

D 19464LOT 8

D 19464LOT 9

SEA CONTAINER

SEA CONTAINERS

LARGE METALOVERHANG

LARGE METAL OVERHANG

SECOND STOREY BALCONY

FIREHYDRANTBOOSTER

TWIN HEADFIRE HYDRANT

DATUM_NAILINBITUMENRL 18.75SEPTIC

PUMP

19.08

19.07

FFL 19

.19

FFL 19.1

8

FFL 19.1

9

FFL 19.1

8

FFL 19.2

1

FFL 19.1

9

FFL19.2

1

19.23

18.90

18.92

18.94

19.27

19.1619

.18

19.19

19.30

19.29

19.15

19.02

19.11

19.15

19.22

19.10

19.10 19

.0819

.09

19.09

19.10 19

.00 18.99

18.9919

.0019

.11

19.09

19.17

19.12 19

.1219

.14 19.22

19.14

19.13

19.16

19.12

19.14

19.15

19.06

19.07

19.10

19.06

19.25

19.18

19.15

19.14

19.12 19

.15

18.84

18.82

18.84

19.02

19.05

18.92

19.18

19.09

19.17

19.18 19

.19

19.09

19.03 19

.07 19.0719

.07

19.09

19.00

19.01

18.97

18.97

18.96

18.9718

.93

18.91

18.96

19.11 19

.09

19.0419

.22

19.13 19

.05

19.0219

.02

18.99

18.98

18.93

19.13

19.06

19.12

19.08

19.11

19.08

18.98

18.97

19.15

18.93

18.96

19.02

19.17

19.09

19.0918

.96

19.04

19.07

19.11

19.12

19.03

19.17

19.18

19.06

19.12

19.10

19.14

19.11

19.15

19.08

19.08

19.16

19.11

19.06

19.10 19

.09

19.07

19.09

19.03

19.09 19

.06

19.06

18.89

18.92

18.91

18.88 18

.87

18.95

18.94 18

.95

18.98

18.96

18.94

18.98

19.11

19.06

18.88

18.89

18.95

18.9418

.9718

.9818

.97

18.96

18.98

18.9918

.96

18.9518

.9818

.99

18.9818

.99

18.98

18.90

18.89

18.85

18.85

18.89

18.90

18.77

18.71

18.73 18

.74

19.19

19.07

19.06

19.08

19.16

19.19

19.05

19.02

19.0019

.01

19.08

19.16

19.00

18.98

18.97 18

.9618

.9718.97

19.01

18.99

19.00

18.90 18

.9018

.8818.90

18.8918

.9119.02

19.00

18.98

19.03 19

.0119

.04

19.03

19.05

19.02

19.06

19.02

19.02

19.05

18.94

18.97

18.99

19.04

19.1519

.05

19.04

19.04

19.03 19

.05

18.75

18.71

18.83

18.88

18.92

18.85

18.96

18.97

18.94

18.89

18.98

18.90

18.90

18.94

19.14

19.12

19.11

19.13

19.04

18.93

18.95

18.93

19.00

18.94

19.00

18.99

18.96

19.02

19.04

19.00

18.98

18.94

18.94

19.00

19.00

18.95

18.94

18.94

18.97

18.77

18.90

18.94

18.96

18.9519

.01

19.11

19.21

19.18

19.13

19.05

19.01

19.05 19

.01

18.96

18.97

18.93

19.15

19.02

19.01

18.99

19.12

19.1619.1719.19

19.18 19

.17 19.19

19.19

19.19

19.18

19.19

19.18

19.17

19.17

19.17

19.16 19

.08

19.16

19.17

19.15

19.23

19.18

19.16

19.15

19.03

18.89

18.89

18.89

18.9018

.88

18.88

18.88

18.86

18.87

19.20

19.08

18.98

18.96

18.90

18.99

18.84

18.75

18.46

18.53

18.54

18.40

18.5918

.4818.43

18.66

18.61

18.61

18.54

18.62 18

.71

19.05

19.03

19.13

19.06

19.05

19.06

19.08

18.95

19.04

18.88

18.98

19.08

19.13

19.07

19.01

19.09

19.10

19.03

19.00

19.06

19.09

19.13

19.17

19.02

18.97

18.94

19.0919

.09

19.08

19.09 19

.17

19.02

18.68

18.68

18.68 18

.72

19.0618

.98

18.99

18.98

18.99

18.99

18.99

18.99

19.03

19.06 19

.17

19.07

19.06

19.17

19.21

19.26

19.021

9.00

19.10 18

.9818.9819

.11

19.19

19.17

19.11

19.12

19.15

19.10

19.13

19.17

19.11

19.20

19.04

19.04

19.03

19.03

18.78

18.86

18.83

19.07

18.9018

.89

18.8918

.90

18.60

18.63

18.56

18.64

19.18

19.16

19.16

19.15

19.16

18.92

18.91

18.55 18

.61

18.63 18

.76

18.76 18

.8718

.77

18.89 18

.88 18.93 18

.96

18.96

19.06

19.16

19.16

19.14 19

.1619

.1619

.1719

.14

19.11

19.16

19.01

18.96

19.03

19.04

19.14 19

.06

18.89

19.00

19.04

19.02

19.02

19.00

19.09

19.03

19.02

19.0619

.12

19.02

19.02

18.76

18.65

19.06

18.99

19.08

19.09

19.07

19.08

19.00

19.00

19.00

19.00

19.00

19.00

19.0

0

19.0

0

19.00

19.0

0

19.0019.00

19.00

19.00

19.00

19.00

18.7

018

.80

18.8

0

18.90

18.90

18.90 18.90

18.90

18.9

0

19.10

19.10

19.10

19.10

19.10

19.10

19.1

0

19.1019.10

19.10

19.10

19.10

19.1

0

PORTION OF COLORBONDFENCE TO BE REMOVED

WIRE FENCE

18.97

COLORBONDFENCE

APPROX. 18.35 TONEIGHBOURS FOOTING

APPROX. 17.83 TONEIGHBOURS FOOTING

APPROX. 18.36 TONEIGHBOURS FOOTING

EXISTING INSPECTION PIPE TO BE REMOVED

EXISTING OFFICE

NORTH

S UMM

E RS

UN

SU

N

W ITN

E RH

OT

DRYWINDS

PREVAILING

WIND

&R

AIN

ALL CONTRACTORS WORKING ON THIS PROJECT TO CHECK ALL DIMENSIONSAND NOTES PRIOR TO INITIATING ANY WORKS. ALL DISCREPANCIES TO BENOTIFIED TO THE PROJECT MANAGER STRAIGHT AWAY.

NOTES:- DO NOT SCALE FROM THE SITE SURVEY PLAN.- THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATIONS, REPORTS, CONTRACTS AND DRAWINGS.- ALL DIMENSIONS TAKEN TO STRUCTURAL SURFACES UNLESS OTHERWISE NOTED (STUD FRAMING / CONCRETE PANELS).

Kahlan Commerford
CDC BA3
Page 2: ISSUED FOR BUILDING APPROVAL · DATE OF ISSUE: SCALE: DRAWN: REVISDIAOTNEDESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan

DATE OF ISSUE:

SCALE:

DRAWN:

REVISION DATE DESCRIPTION

Lot 32 #18 Casino Street Welshpool

Client:

Project Title:

Alita Constructions

Site & Landscaping Plan01.05.19

MB

Project Number:

1922Drawing Number:

A2

B

08.05.19

14.07.19

Preliminary Issue for Client Comments

Issued for consultants and building approval

PO Box 2655, Malaga WA 6944

GENERAL NOTES:- DO NOT SCALE FROM DRAWINGS.- THESE PLANS ARE THE SOLE PROPERTY OF DESIGNER AND MAY NOT BEREPRODUCED OR MODIFIED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION.- CONTRACTORS TO CHECK ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO THECOMMENCEMENT OF ANY WORKS AND ANY DISCREPANCIES TO BE BROUGHT TO THEATTENTION OF THE SUPERVISOR.

© COPYRIGHT STATEMENTTHIS DESIGN AND / OR DRAWING IS CONFIDENTIAL AND SHALL REMAIN THE PROPERTYOF QUALITY DESIGN SOLUTIONS PTY LTD. IT MUST NOT BE REPRODUCED, COPIED ORALTERED WITHOUT THE APPROVAL OF QUALITY DESIGN SOLUTIONS PTY LTD.

1:250, 1:100, 1:30,1:1 (A1)

ISSUED FOR BUILDING APPROVAL

A

C 04.08.19 Loading dock roof and electrical amendments

D xx.xx.xx -

Email: [email protected] Mobile: 0403 165 270

FW

SP

OO

N D

RA

IN

AA

BB

CC

1

1

2

2

3

3

4

4

5043

,401

50

50 33,000 135,112

181 30,000 11,000 3,000 19,287 83,611 21,190

9,475

33,70

622

050

13,035 16,965 3,000 17,991 82,500EXISTING CAR BAYS

1,140 14,600EXISTING CAR BAYS

18,881

HORIZONTAL OR VERTICALBICYCLE RACK LOCATION (4 BIKES)2000 x 2000mm CLEARANCE

2500mm x 4500mm REFUSE BIN AREA TBC

ELECTRICAL DISTRIBUTION AND PCDBOARDS AND SITE TEMPORARY POWER

PLUMBER TO INSTALLTEMPORARY STANDPIPE TAPFOR CONSTRUCTION STAGE

WAREHOUSECANOPY OVER

APPROX. LOCATION OF EXISTING SUB BOARDELECTRICAL AND COMMUNICATIONPRELAYS TO BE CONFIRMED ON SITE

RETAINING WALL TOLOADING DOCK RAMP

NEW 1500 x 1500mm TREE AND TREE-WELLSTO BE INSTALLED. TREE-WELLS TO BEPROTECTED BY 150 HIGH CONCRETE KERNSOR BOLTED DOWN RUBBER WHEEL STOPS

150mm CONCRETE HARDSTAND.REFER TO ENGINEERING FORREINFORCING

SEPTIC SYSTEM PUMP CASTED INTO INHARDSTAND WITH INSPECTION LID,LOCATION TO BE CONFIRMED ON SITE

LINK NEW SOAKWELLS TOEXISTING STORMWATERSYSTEM WITH Ø150 PIPE

RETIC PIPE TO BE INSTALLED TO NEWTREE-WELLS AND CONNECTED TOEXISTING RETICULATION SYSTEM.

DOCK LEVELLER RECESSEDPITS WITH CONDUITS. REFERTO MANUFACTURERSSPECIFICATION AND DETAILS

Stace Rogers

30 North RoadBASSENDEAN WA 6054

Ph : (08) 9379 9481 or 0447 112 481

Assoc Dip Civ Eng (AMEIAust)

ALL CARPARK & DRAINAGE DESIGN WORKCARRIED OUT & CERTIFIED BY:

Email : [email protected]

S RCivil Consulting Pty Ltd

REFER TO CONSULTANTS PLANFOR CALCULATIONS AND DETAILS

BOTTOMOF BANK

EXISTING WAREHOUSE

CONCRETE COMMERCIAL BUILDING

PO

STS

COMMERCIALBUILDING

CONCRETECOMMERCIALBUILDING

BOLLARDS

BOLLARDS

CONCRETE

ED

GE

OF

CO

NC

RE

TE

CO

NC

RE

TEC

RO

SS

OV

ER

ED

GE

OF

EX

ISTI

NG

CO

NC

RE

TE

DOME POWERPOLE

POWERPOLE

METAL FENCE

COLORBONDFENCE

METAL FENCE

STE

EL FE

NC

E R

EN

DE

RE

DW

ALL S

EG

ME

NTS

WV WATER

VALVE

GASVALVE

PIT DEPTH2.2 DIA 1.8

PIT DEPTH2.03 DIA 1.8

PIT DEPTH1.9 DIA 1.8

PIT DEPTH2.1 DIA 1.8

PIT DEPTH1.76 DIA 1.8

PIT DEPTH1.95 DIA 1.8

PIT DEPTH2.14 DIA 1.8

PIT DEPTH2.07 DIA 1.8

PIT DEPTH1.9 DIA 1.8

PIT DEPTH1.82 DIA 1.8

PIT DEPTH1.74 DIA 1.8

PIT DEPTH1.81 DIA 1.8 K

ER

B

KERB

KE

RB

KERBKERB

KE

RB

KE

RB

KE

RB

METALMANHOLE

METALMANHOLE

METALMANHOLES MANHOLES

PIPE

PIPES DESTINATIONNOT KNOWN

DRAINAGE PIT PIPESUNMEASURABLE

INV 18.3DIA0.15

INV

18.25DIA

0.15

INV 18.24DIA

0.15

INV 18.25DIA0.15

INV

18.28DIA

0.15

INV 18.24DIA0.15

INV

18.19DIA

0.15IN

V 18.24D

IA0.15

INV

18.38DIA

0.15

INV 18.28DIA0.15

INV 18.28DIA0.15

INV 18.26DIA0.15

INV 18.28DIA

0.15

INV 18.26DIA

0.15

INV 18.29DIA0.15 INV 18.32DIA

0.15

PIN

V 18.27D

0.15 INV 18.3DIA

0.15

INV 18.26DIA0.15

INV 18.31DIA0.15

INV 18.27DIA

0.15

INV

18.2

8DIA

0.15

INV 18

.27DIA

0.15

INV 18.26DIA0.15

INV 18.33DIA0.15

INV 18.26DIA

0.15 INV

18.3

1DIA

0.15

INV 18

.3DIA

0.15

INV 18.29DIA0.15

INV 18.21DIA0.15

INV 18.27D

IA

0.15 INV 18.24DIA

0.15

INV 18.24DA

0.15

INV 18.29D

IA

0.15

INV 18.27D

IA0.15

INV 18.23DIA

0.15

INV 18.27DIA0.15

INV 18.26DIA0.15

INV

18.31DIA

0.15

INV 18.23DIA

0.15

INV

18.27DIA

0.15IN

V 18.19D

IA0.15

INV 18.13DIA0.15

INV

18.18DIA

0.15

WATER TANKPUMP SHED

WATERTANK

WATER TANK

TELSTRA PIT

CO

NC

RE

TE W

ALL

CONCRETE WALL

BR

ICK

WA

LLC

ON

CR

ETE

WA

LL

CONCRETE WALL

WATERMETER

WV

WV WV

VALVE

89°49'40" 90°1'

50"

89°58'10"90°10'20"

43.

5

168.16

43.5

168.26

7317 m²LOT 32

CA

SIN

O

STR

EE

T

D 69416

LOT 23

D 97259LOT 31

D 19464LOT 10

D 19464LOT 7

D 19464LOT 8

D 19464LOT 9

LARGE METALOVERHANG

LARGE METAL OVERHANG

SECOND STOREY BALCONY

FIREHYDRANTBOOSTER

TWIN HEADFIRE HYDRANT

DATUM_NAILINBITUMENRL 18.75SEPTIC

PUMP

19.08

19.07

FFL 19

.19

FFL 19.1

8

FFL 19.1

9

FFL 19.1

8

FFL 19.2

1

FFL 19.1

9

FFL19.2

1

19.23

18.90

18.92

18.94

19.27

19.1619

.18

19.19

19.30

19.29

19.15

19.02

19.11

19.15

19.22

19.10

19.10 19

.0819

.09

19.09

19.10 19

.00 18.99

18.9919

.0019

.11

19.09

19.17

19.12 19

.1219

.14 19.22

19.14

19.13

19.16

19.12

19.14

19.15

19.06

19.07

19.10

19.06

19.25

19.18

19.15

19.14

19.12 19

.15

18.84

18.82

18.84

19.02

19.05

18.92

19.18

19.09

19.17

19.18 19

.19

19.09

19.03 19

.07 19.0719

.07

19.09

19.00

19.01

18.97

18.97

18.96

18.9718

.93

18.91

18.96

19.11 19

.09

19.0419

.22

19.13 19

.05

19.0219

.02

18.99

18.98

18.93

19.13

19.06

19.12

19.08

19.11

19.08

18.98

18.97

19.15

18.93

18.96

19.02

19.17

19.09

19.0918

.96

19.04

19.07

19.11

19.12

19.03

19.17

19.18

19.06

19.12

19.10

19.14

19.11

19.15

19.08

19.08

19.16

19.11

19.06

19.10 19

.09

19.07

19.09

19.03

19.09 19

.06

19.06

18.89

18.92

18.91

18.88 18

.87

18.95

18.94 18

.95

18.98

18.96

18.94

18.98

19.11

19.06

18.88

18.89

18.95

18.9418

.9718

.9818

.97

18.96

18.98

18.9918

.96

18.9518

.9818

.99

18.9818

.99

18.98

18.90

18.89

18.85

18.85

18.89

18.90

18.77

18.71

18.73 18

.74

19.19

19.07

19.06

19.08

19.16

19.19

19.05

19.02

19.0019

.01

19.08

19.16

19.00

18.98

18.97 18

.9618

.9718.97

19.01

18.99

19.00

18.90 18

.9018

.8818.90

18.8918

.9119.02

19.00

18.98

19.03 19

.0119

.04

19.03

19.05

19.02

19.06

19.02

19.02

19.05

18.94

18.97

18.99

19.04

19.1519

.05

19.04

19.04

19.03 19

.05

18.75

18.71

18.83

18.88

18.92

18.85

18.96

18.97

18.94

18.89

18.98

18.90

18.90

18.94

19.14

19.12

19.11

19.13

19.04

18.93

18.95

18.93

19.00

18.94

19.00

18.99

18.96

19.02

19.04

19.00

18.98

18.94

18.94

19.00

19.00

18.95

18.94

18.94

18.97

18.77

18.90

18.94

18.96

18.9519

.01

19.11

19.21

19.18

19.13

19.05

19.01

19.05 19

.01

18.96

18.97

18.93

19.15

19.02

19.01

18.99

19.12

19.1619.1719.19

19.18 19

.17 19.19

19.19

19.19

19.18

19.19

19.18

19.17

19.17

19.17

19.16 19

.08

19.16

19.17

19.15

19.23

19.18

19.16

19.15

19.03

18.89

18.89

18.89

18.9018

.88

18.88

18.88

18.86

18.87

19.20

19.08

18.98

18.96

18.90

18.99

18.84

18.75

18.46

18.53

18.54

18.40

18.5918

.4818.43

18.66

18.61

18.61

18.54

18.62 18

.71

19.05

19.03

19.13

19.06

19.05

19.06

19.08

18.95

19.04

18.88

18.98

19.08

19.13

19.07

19.01

19.09

19.10

19.03

19.00

19.06

19.09

19.13

19.17

19.02

18.97

18.94

19.0919

.09

19.08

19.09 19

.17

19.02

18.68

18.68

18.68 18

.72

19.0618

.98

18.99

18.98

18.99

18.99

18.99

18.99

19.03

19.06 19

.17

19.07

19.06

19.17

19.21

19.26

19.021

9.00

19.10 18

.9818.9819

.11

19.19

19.17

19.11

19.12

19.15

19.10

19.13

19.17

19.11

19.20

19.04

19.04

19.03

19.03

18.78

18.86

18.83

19.07

18.9018

.89

18.8918

.90

18.60

18.63

18.56

18.64

19.18

19.16

19.16

19.15

19.16

18.92

18.91

18.55 18

.61

18.63 18

.76

18.76 18

.8718

.77

18.89 18

.88 18.93 18

.96

18.96

19.06

19.16

19.16

19.14 19

.1619

.1619

.1719

.14

19.11

19.16

19.01

18.96

19.03

19.04

19.14 19

.06

18.89

19.00

19.04

19.02

19.02

19.00

19.09

19.03

19.02

19.0619

.12

19.02

19.02

18.76

18.65

19.06

18.99

19.08

19.09

19.07

19.08

19.00

19.00

19.00

19.00

19.00

19.00

19.0

0

19.0

0

19.00

19.0

0

19.00

19.00

19.00

19.00

19.00

19.00

18.7

018

.80

18.8

0

18.90

18.90

18.90 18.90

18.90

18.9

0

19.10

19.10

19.10

19.10

19.10

19.10

19.1

0

19.1019.10

19.10

19.10

19.10

19.1

0

WIRE FENCE

PROPOSED WAREHOUSEFFL: 19.19

A: 1,141.29m2

PROPOSED LOADING DOCKA: 160.74m2

TAP

TAP

FHR

FHR

18.97

COLORBONDFENCE

19.17

FE

FE

19.17

19.17

19.17

CONCRETE HARDSTAND.REFER TO ENGINEERING

FOR REINFORCING17.89

17.89

NOTE: ALL INTERCONNECTINGSTORMWATER PIPES TO BE Ø150

UPVC AT 1in100 MIN GRADEUNLESS NOTED OTHERWISE

NOTE: ALL SOAKWELLS TOBE Ø1800 x 1200 DEEP

UNLESS NOTED OTHERWISE

APPROX. 18.35 TONEIGHBOURS FOOTING

APPROX. 17.83 TONEIGHBOURS FOOTING

APPROX. 18.36 TONEIGHBOURS FOOTING

17.88

17.88

EXISTING OFFICE

LID 18.95

18.06 18.26 18.83

1m 9m @ 2% 4m @ 5% 7m @ 8%

18.06 18.26 18.83

19.17

LID 18.95

LID 18.95

LID 18.95

LID 18.95

LID 18.95

19.00

4m @ 4.2%

19.00

19.00

LANDSCAPE LEGENDSYMBOL SPECIES TYPE

TREECALLISTEMON 'KINGS PARK SPECIAL'

QUANTITY

18

BOL

BOL

BOLBOL

BOL

BOL

BOL

BOL

BOL

DP

DP

DP

DP

DP

DP

DP

BOLDP

DP

DP

DP

MIN

650m

m PI

PE C

OVER 150mm THICK CONCRETE

Ø150 STORMWATER PIPE

200mm COMPACTEDSAND BASE

Services LegendSymbol Description

---

ELECTRICAL DISTRIBUTION BOARD

NBN PCD BOX

TEMPORARY POWER 10A DOUBLE WP GPO @ 1200

NORTH

S UMM

E RS

UN

SU

N

W ITN

E RH

OT

DRYWINDS

PREVAILING

WIND

&R

AIN

Site Plan1:250

Stormwater Detail1:100

ALL CONTRACTORS WORKING ON THIS PROJECT TO CHECK ALL DIMENSIONSAND NOTES PRIOR TO INITIATING ANY WORKS. ALL DISCREPANCIES TO BENOTIFIED TO THE PROJECT MANAGER STRAIGHT AWAY.

NOTES:- THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATIONS, REPORTS, CONTRACTS AND DRAWINGS.- ALL BUILDING WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE REQUIRED AUSTRALIA STANDARDS AND THE NCC.- ALL EXISTING STRUCTURES ARE DRAWN APPROX. FOR EXACT DIMENSIONING, SIZE & LOCATION CHECK ON SITE.- ALL DIMENSIONING & LOCATIONS ARE REFERENCED BACK TO EXISTING STRUCTURES. ANY DISCREPANCY CONFIRM WITH OWNER OR BUILDER.- ALL DIMENSIONS TO PROPOSED WORK TAKEN TO STRUCTURAL SURFACES UNLESS OTHERWISE NOTED (STUD FRAMING / CONCRETE PANELS ETC).- NO ALLOWANCE FOR INTERNAL AND EXTERNAL SHEETING. ANY DISCREPANCY CONFIRM WITH OWNER OR BUILDER.- CARE SHOULD BE TAKEN TO INCLUDE AN ALLOWANCE IN CALCULATION OF CLEARANCE REQUIRED FOR FIXINGS ETC.

SITE NOTES:- REFER TO A4 ROOF PLAN FOR DOWNPIPE INFORMATION.- EXTEND COMPACTION 1.5m PAST THE BUILDING.- TELSTRA PIT & POWER DOME POSITIONS TO BE CONFIRMED ON SITE. CONDUIT RUNS ARE INDICATIVE ONLY, CONTRACTOR TO CONFIRM ON SITE.- NBN CURRENTLY NOT AVAILABLE (PROPOSED FTTC), DEVELOPMENT MUST COMPLY WITH NBN STANDARDS.- WATER, SEWER AND FIRE SERVICES TO BE CHECKED PRIOR TO CONSTRUCTION BY BUILDER.- POWER AND COMMUNICATION SERVICES LOCATIONS TO BE CONFIRMED ON SITE AND APPLICATIONS BY OWNER AND BUILDER.

ABREVIATIONS:- FE = FIRE EXTINGUISHER.- FHR = FIRE HOSE REEL.- COL = COLUMN.- DP = DOWNPIPE.- PJ = PANEL JOINT.

36m FIRE HOSE REEL

Page 3: ISSUED FOR BUILDING APPROVAL · DATE OF ISSUE: SCALE: DRAWN: REVISDIAOTNEDESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan

DATE OF ISSUE:

SCALE:

DRAWN:

REVISION DATE DESCRIPTION

Lot 32 #18 Casino Street Welshpool

Client:

Project Title:

Alita Constructions

Ground Floor Plan01.05.19

MB

Project Number:

1922Drawing Number:

A3

B

08.05.19

14.07.19

Preliminary Issue for Client Comments

Issued for consultants and building approval

PO Box 2655, Malaga WA 6944

GENERAL NOTES:- DO NOT SCALE FROM DRAWINGS.- THESE PLANS ARE THE SOLE PROPERTY OF DESIGNER AND MAY NOT BEREPRODUCED OR MODIFIED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION.- CONTRACTORS TO CHECK ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO THECOMMENCEMENT OF ANY WORKS AND ANY DISCREPANCIES TO BE BROUGHT TO THEATTENTION OF THE SUPERVISOR.

© COPYRIGHT STATEMENTTHIS DESIGN AND / OR DRAWING IS CONFIDENTIAL AND SHALL REMAIN THE PROPERTYOF QUALITY DESIGN SOLUTIONS PTY LTD. IT MUST NOT BE REPRODUCED, COPIED ORALTERED WITHOUT THE APPROVAL OF QUALITY DESIGN SOLUTIONS PTY LTD.

1:100, 1:20, 1:50,1:10 (A1)

ISSUED FOR BUILDING APPROVAL

A

C 04.08.19 Loading dock roof and electrical amendments

D xx.xx.xx -

Email: [email protected] Mobile: 0403 165 270

15.28 m2

W01

D08

D07

D09

D06

D03

D02

D04

D05

D01

AA

FW

BB

CC

1

1

2

2

3

3

4

4

SP

OO

N D

RA

IN

AA

B B

220 29,560 220 11,000 3,000

30,000 14,000

13,035 16,965 14,000

220 12,595 220 16,745 220 3,000

220 9,950 2,865 7,367 76 1,270 76 2,780 76 5,100 220 3,000

9,475

33,92

6

43,40

1

220

42,96

122

0

9,475

33,70

622

0

220

9,255

220

33,48

622

0

220

1,524

2,160

1,841

2,160

1,570

220

2,860

7630

,550

220

220

1,404

2,400

1,601

2,400

1,450

820

1,900

2,461

1,020

1,200

5,500

6,700

1,200

5,500

5,435

1,020

950

220

220

204,6

0320

4,603

203,3

8120

3,381

203,3

3020

3,330

203,3

3020

3,330

203,3

3020

3,330

203,3

7920

3,379

1622

0

3,316 20 3,316 20 3,316 20 3,316 20 3,316 20 3,316 20 3,316 20 3,316 20 3,316 20 4,647 20 4,647 20 4,647

2,418

220

500

1,500

323

3,650

150

3,650

4,148

2,110

3,300

2,110

3,300

2,280

3,300

2,110

3,300

2,110

3,780

840

500

220

600 24,325 4,635

600 17,675 11,285

600 1,500 455 3,650 6,390

2,543 20 2,543 20 2,543 20 2,543 20 2,543 20 2,866 20 2,866 20 2,866 20 2,866 20 2,866 20 2,866 20 2,866

220 12,595 220 20 3,325 20 3,325 20 3,325 20 3,325 20 3,325 20 220

3,275

202,8

8620

1,200

5,500

1,200

5,500

1,200

5,500

1,200

203,0

7220

3,072

2122

0

220

204,7

1820

4,717

1,500

1,500

500

250

500

250

E4E3

E2E1

E5

E6

2500mm x 4500mm REFUSE BIN AREA TBC

PRELAYS ONLY FORFUTURE KITCHENETTE

LINE OF TIMBER FRAMECEILING LID ABOVE

9000mm HIGH RACKING TYPICAL

9000mm HIGH RACKING TYPICAL

9000mm HIGH RACKING TYPICAL

76mm STEEL STUD FRAMING WITH 10mmPLASTERBOARD BOTH SIDES TO ALL WALLS OTHERTHAN WET AREAS. WATER RESISTANT PLASTERBOARDTO BE USED IN WET AREAS. WALLS TO UNDERSIDE OFTIMBER FRAMED CEILING LID ABOVE. R1.5 INSULATIONREFER TO ENERGY REPORT FOR DETAILSWALL LINING WITH R2.0 INSULATION.REFER TO ENERGY REPORT FOR DETAILS

DOCK LEVELLER RECESSED PITS ANDCONDUITS. REFER TO MANUFACTURERSSPECIFICATION AND DETAILS

CANOPY OVER

ELECTRICAL DISTRIBUTION AND PCDBOARDS AND SITE TEMPORARY POWER

RETAINING WALL TO LOADING DOCK RAMP

ROLLER SHUTTER/DOOR APRON TOBE POURED WITH MAIN SLAB TYPICAL

ALL EXTERNAL DOWNPIPES TO BE PVC⌀150mm UNO. REFER TO ROOF PLAN ON A4

300mm THICK CONCRETE PANEL

300mm THICK CONCRETE PANEL

300mm THICK CONCRETE PANEL

300mm THICK CONCRETE PANEL

PROPOSED WAREHOUSEFFL: 19.19

A: 1,141.29m2

PROPOSED LOADING DOCKFFL: TBC

A: 160.74m2

TAP

TAP

FHR

FHR

150mm CONCRETE FLOOR.REFER TO ENGINEERS DETAILS

CONCRETE LOADING DOCKHARDSTAND. REFER TO

ENGINEERS DETAILS

1m 9m @ 2% 4m @ 5% 7m @ 8% 4m @ 4.2%

FE

FE

REFER TO A8 FORAMENITIES DETAILS

BOL

BOL

BOL

BOL

BOL

BOL

BOL

BOL

BOL

DP

DP

DP

DP

DP

UNISEXACCESSIBLE

OFFICE

DP

DP

DP

DP

DP

DP

BOL

50

CONCRETE PANEL

STRIP FOOTING

150mm DOWNPIPE

150mm DOWNPIPE

CONCRETE SLAB

DOWNPIPES TOBE GLUED

1000

500 MIN

OBSTRUCTION OR INTERNAL CORNER

TACTILE EXIT SIGN AS PER NCC& AS1428.1 2009

NOTES:- ALL DOOR HANDLES TO BE INSTALLED IN ACCORDANCE WITH SECTION13 OF AS 1428.1 (PART 1) AND BE COMPLIANT WITH D2.21 OF THE NCC- REFER TO SPECIFICATION FOR INFORMATION ON DOOR HARDWARE- ALL SWITCHES & CONTROLS ARE REQUIRED TO BE INSTALLED INACCORDANCE WITH SECTION 14 OF AS 1428.1 (PART 1)

CONCRETE PANEL

10mm GYPROCK LINING

WALL INSULATION

STUD WORK TO BEAT 600mm CENTERS

REFER TO ENERGY REPORTFOR INSULATION RATING

1,000

1,000

FIRE EXTINGUISHER SIGNTO BE INSTALLED HERE

FIRE EXTINGUISHER TOBE INSTALLED HERE

1,400

MIN.

500

300mm x 225mm FIRE HOSE REELSIGN TO BE INSTALLED HERE

36mm FIRE HOSE REEL

NORTH

S UMM

E RS

UN

SU

N

W ITN

E RH

OT

DRYWINDS

PREVAILING

WIND

&R

AIN

Ground Floor Plan1:100

Downpipe Detail1:20

Switch & Handle Detail1:50

Insulation Detail1:10

Fire Extinguisher Sign1:50

Fire Hose Reel Sign1:50

ALL CONTRACTORS WORKING ON THIS PROJECT TO CHECK ALL DIMENSIONSAND NOTES PRIOR TO INITIATING ANY WORKS. ALL DISCREPANCIES TO BENOTIFIED TO THE PROJECT MANAGER STRAIGHT AWAY.

FLOOR PLAN NOTES:- REFER TO A4 FOR ALL ROOF PLAN AND DOWNPIPE INFORMATION.- REFER TO A7 FOR ALL ELECTRICAL AND CEILING WORKS.- REFER TO A8 FOR ALL AMENITIES LAYOUTS, DOOR AND WINDOW SCHEDULE INFORMATION.- ALL EXIT DOORS WITH ILLUMINATED SIGNS TO HAVE BRAILE SIGNAGE. INSTALL BRAILLE/TACTILE SIGNAGE AS PER NCC CLAUSE D3.6 AND IN ACCORDANCE WITH AS1428.1.- VENTILATION, AIR-CONDITIONING AND MECHANICAL SYSTEMS TO BE DESIGNED AND INSTALLED AS PER NCC AND AS1668.2. REFER TO ENERGY REPORT PARTS J5 AND J6.- REFER TO ENERGY REPORT FOR ALL ROOF, CEILING AND WALL INSULATION REQUIREMENTS.

NOTES:- THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATIONS, REPORTS, CONTRACTS AND DRAWINGS.- ALL BUILDING WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE REQUIRED AUSTRALIA STANDARDS AND THE NCC.- ALL DIMENSIONS TAKEN TO STRUCTURAL SURFACES UNLESS OTHERWISE NOTED (STUD FRAMING / CONCRETE PANELS ETC). NOALLOWANCE FOR INTERNAL AND EXTERNAL SHEETING. ANY DISCREPANCY CONFIRM WITH OWNER OR BUILDER.- CARE SHOULD BE TAKEN TO INCLUDE AN ALLOWANCE IN CALCULATION OF CLEARANCE REQUIRED FOR FIXINGS ETC.

ABREVIATIONS:- FE = FIRE EXTINGUISHER.- FHR = FIRE HOSE REEL.- COL = COLUMN.- DP = DOWNPIPE.- PJ = PANEL JOINT.

FLOOR PLAN NOTES CONTINUED:- AIR-CONDITIONING SYSTEMS TO BE CONFIRMED AT TENDER STAGE. ALLOWANCE TO BE MADE FOR TUNDISH AND LOCATION TO BE CONFIRMED ON SITE.- FIRE HOSE REEL'S TO COMPLY WITH AS2441 AND FIRE EXTINGUISHER'S TO COMPLY WITH AS2444 AND AS3745.- TIMBER WORKS SHALL COMPLY WITH THE LIGHT TIMBER FRAMING CODE AS1684.- TERMITE MANAGEMENT AS PER NCC CLAUSES B1.4 & F1.9 AND IN ACCORDANCE WITH AS3660 PART 1.- CONCRETE WORKS TO COMPLY WITH AS3600 AND MASONRY WORKS TO COMPLY WITH AS3700.

Page 4: ISSUED FOR BUILDING APPROVAL · DATE OF ISSUE: SCALE: DRAWN: REVISDIAOTNEDESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan

DATE OF ISSUE:

SCALE:

DRAWN:

REVISION DATE DESCRIPTION

Lot 32 #18 Casino Street Welshpool

Client:

Project Title:

Alita Constructions

Roof Plan01.05.19

MB

Project Number:

1922Drawing Number:

A4

B

08.05.19

14.07.19

Preliminary Issue for Client Comments

Issued for consultants and building approval

PO Box 2655, Malaga WA 6944

GENERAL NOTES:- DO NOT SCALE FROM DRAWINGS.- THESE PLANS ARE THE SOLE PROPERTY OF DESIGNER AND MAY NOT BEREPRODUCED OR MODIFIED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION.- CONTRACTORS TO CHECK ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO THECOMMENCEMENT OF ANY WORKS AND ANY DISCREPANCIES TO BE BROUGHT TO THEATTENTION OF THE SUPERVISOR.

© COPYRIGHT STATEMENTTHIS DESIGN AND / OR DRAWING IS CONFIDENTIAL AND SHALL REMAIN THE PROPERTYOF QUALITY DESIGN SOLUTIONS PTY LTD. IT MUST NOT BE REPRODUCED, COPIED ORALTERED WITHOUT THE APPROVAL OF QUALITY DESIGN SOLUTIONS PTY LTD.

1:100 (A1)

ISSUED FOR BUILDING APPROVAL

A

C 04.08.19 Loading dock roof and electrical amendments

D xx.xx.xx -

Email: [email protected] Mobile: 0403 165 270

⌀150mm PVC DOWNPIPE WITH450mm x 450mm SUMP JET

⌀150mm PVC CANOPY DOWNPIPES WITH450mm x 450mm SUMP JETS BELOW

CANOPY BELOW

SELECTED COLORBOND CAPPING WITHZINCALUME FLASHING FIXED TO CONCRETE PANEL

600mm x 150mm DEEP (MIN. DEPTH) 0.55mm THICKZINCALUME BOX GUTTER ON SPANDEK ON 50mm WIDEGUTTER STRAPS WITH SADDLES AT MAX. 600mm CTRS.FALL GUTTER TO OUTLET AT MIN. 1:200

ROOF LINE TO START WITHIN 150mmOF THE TOP OF CONCRETE PANELCONCRETE TILT PANELS

CONCRETE TILT PANELS

CONCRETE TILT PANELCONCRETE TILT PANELS

SELECTED COLORBOND CAPPING WITHZINCALUME FLASHING FIXED TO CONCRETE PANEL

600mm x 150mm DEEP (MIN. DEPTH) 0.55mm THICKZINCALUME BOX GUTTER BELOW ON SPANDEK ON 50mmWIDE GUTTER STRAPS WITH SADDLES AT MAX. 600mmCTRS. FALL GUTTER TO OUTLET AT MIN. 1:200. ⌀150mmOVERFLOW POP, LOCATION TO BE CONFIRMED ON SITE

200mm x 200mm DEEP (MIN. DEPTH) COLORBONDEAVES GUTTER TO MAIN ROOF. FALL GUTTER TOOUTLET AT MIN. 1:200. ALLOW FOR OVERFLOW POPS

⌀150mm PVC LOADING DOCK DOWNPIPE TO BOXED GUTTER.DOWNPIPE WITH BEND AROUND ROOF TIE BEAM

PITCH 3° PITCH 3°

PITCH 3°

PITCH 3°

PITCH 3°

LOWER 600mm x 150mm DEEP (MIN. DEPTH)COLORBOND BOXED GUTTER. FALL GUTTER TOOUTLET AT MIN. 1:200. ALLOW FOR OVERFLOW POPS

TYPICAL SKYLIGHT - FGW TOPGLASS GC TRANSLUCENTSHEETING. SAFETY WIRE 300mm x 150mm x 2.0mm TOTHE UNDERSIDE AS PER AS 1562.3:1996 CLAUSE 2.4.3.SKYLIGHT LOCATIONS TO SUIT RACKING LAYOUTS

ROOF SHEETING TO BE TRIMDECK OR SIMILARWITH 55mm ANTICON SUPPORTED WITH 300mm x150mm x 2.0mm SAFETY WIRE AT 3° PITCH UNO.

CANOPY ROOF SHEETING TO BE TRIMDECKOR SIMILAR WITH 300mm x 150mm x 2.0mmSAFETY WIRE AT 3° PITCH UNO.

LOWER ROOF SHEETING TO BE TRIMDECK OR SIMILARWITH 55mm ANTICON SUPPORTED WITH 300mm x 150mmx 2.0mm SAFETY WIRE AT 3° PITCH UNO.

ROOF SHEETING TO RUN OVER TOPOF WALL GIRTS AND CLADDING

CONCRETE TILT PANEL WALL BELOW, ROOFSHEETING TO RUN OVER TOP OF PANEL

ROOF SHEETING TO RUN OVER CONCRETE PANEL

CONCRETE TILT PANEL WALL BELOW, ROOFSHEETING TO RUN OVER TOP OF PANEL

ROOF SHEETING TO RUN OVER TOPOF WALL GIRTS AND CLADDING

3x 150mm x 150mm COLORBOND DOWNPIPES TO MAIN ROOFEAVES GUTTER. DOWNPIPES TO RUN ONTO CANOPY ROOF BELOW

CONCRETE TILT PANEL WALL BELOW, ROOFSHEETING TO RUN OVER TOP OF PANEL

⌀150mm PVC DOWNPIPE WITH450mm x 450mm SUMP JET

DP

TRANSLUCENT SHEETING

ROOF TRUSS REFER TO ENGINEERS DETAILS

EXPOSED CANOPY RAFTER REFER TO ENGINEERS DETAILS

TRANSLUCENT SHEETING

TRANSLUCENT SHEETING

TRANSLUCENT SHEETING

TRANSLUCENT SHEETING

TRANSLUCENT SHEETING

EXPOSED CANOPY RAFTER REFER TO ENGINEERS DETAILS

EXPOSED CANOPY RAFTER REFER TO ENGINEERS DETAILS

EXPOSED CANOPY RAFTER REFER TO ENGINEERS DETAILS

EXPOSED CANOPY RAFTER REFER TO ENGINEERS DETAILS

TRANSLUCENT SHEETING TRANSLUCENT SHEETING

TRANSLUCENT SHEETING

TRANSLUCENT SHEETING

TRANSLUCENT SHEETING

TRANSLUCENT SHEETING

TRANSLUCENT SHEETING

ROOF TRUSS REFER TO ENGINEERS DETAILS

ROOF TRUSS REFER TO ENGINEERS DETAILS ROOF TRUSS REFER TO ENGINEERS DETAILS

ROOF TRUSS REFER TO ENGINEERS DETAILS ROOF TRUSS REFER TO ENGINEERS DETAILS

ROOF TRUSS REFER TO ENGINEERS DETAILS ROOF TRUSS REFER TO ENGINEERS DETAILS

RAFTER REFER TO ENGINEERS DETAILS

DP

DP

DP

DP

DP

DP

DP

DP

DP

DP

DP

DP

DP

NORTH

S UMM

E RS

UN

SU

N

W ITN

E RH

OT

DRYWINDS

PREVAILING

WIND

&R

AIN

Roof Plan1:100

ALL CONTRACTORS WORKING ON THIS PROJECT TO CHECK ALL DIMENSIONSAND NOTES PRIOR TO INITIATING ANY WORKS. ALL DISCREPANCIES TO BENOTIFIED TO THE PROJECT MANAGER STRAIGHT AWAY.NOTE:

OVERFLOW POPS WHERE NOTED AND LOCATE ALLOVERFLOW POPS SO AS TO ENSURE POPS ARE 25mmBELOW TOP OF GUTTER AT IT'S LOWEST POINT.

ROOF PLAN NOTES:- VENTILATION, AIR-CONDITIONING AND MECHANICAL SYSTEMS TO BE DESIGNED AND INSTALLED AS PER NCC AND AS1668.2. REFER TO ENERGY REPORT PARTS J5 AND J6.- REFER TO ENERGY REPORT FOR ALL ROOF, CEILING AND WALL INSULATION REQUIREMENTS.- AIR-CONDITIONING SYSTEMS TO BE CONFIRMED AT TENDER STAGE. ALLOWANCE TO BE MADE FOR TUNDISH AND LOCATION TO BE CONFIRMED ON SITE.- ROOF SAFETY AND ACCESS AS PER SAFETY SPECIALIST DESIGN, REFER TO SPECIFICATION. ANCHORS TO COMPLY WITH AS1891 AND AS5532.- TIMBER WORKS SHALL COMPLY WITH THE LIGHT TIMBER FRAMING CODE AS1684.- TERMITE MANAGEMENT AS PER NCC CLAUSES B1.4 & F1.9 AND IN ACCORDANCE WITH AS3660 PART 1.- CONCRETE WORKS TO COMPLY WITH AS3600 AND MASONRY WORKS TO COMPLY WITH AS3700.- ALL SHEET ROOF AND WALL CLADDING WORKS SHALL BE IN ACCORDANCE WITH AS1562.

NOTES:- THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATIONS, REPORTS, CONTRACTS AND DRAWINGS.- ALL BUILDING WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE REQUIRED AUSTRALIA STANDARDS AND THE NCC.- ALL DIMENSIONS TAKEN TO STRUCTURAL SURFACES UNLESS OTHERWISE NOTED (STUD FRAMING / CONCRETE PANELS ETC). NOALLOWANCE FOR INTERNAL AND EXTERNAL SHEETING. ANY DISCREPANCY CONFIRM WITH OWNER OR BUILDER.- CARE SHOULD BE TAKEN TO INCLUDE AN ALLOWANCE IN CALCULATION OF CLEARANCE REQUIRED FOR FIXINGS ETC.

ABREVIATIONS:- FE = FIRE EXTINGUISHER.- FHR = FIRE HOSE REEL.- COL = COLUMN.- DP = DOWNPIPE.- PJ = PANEL JOINT.

Page 5: ISSUED FOR BUILDING APPROVAL · DATE OF ISSUE: SCALE: DRAWN: REVISDIAOTNEDESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan

DATE OF ISSUE:

SCALE:

DRAWN:

REVISION DATE DESCRIPTION

Lot 32 #18 Casino Street Welshpool

Client:

Project Title:

Alita Constructions

Elevations01.05.19

MB

Project Number:

1922Drawing Number:

A5

B

08.05.19

14.07.19

Preliminary Issue for Client Comments

Issued for consultants and building approval

PO Box 2655, Malaga WA 6944

GENERAL NOTES:- DO NOT SCALE FROM DRAWINGS.- THESE PLANS ARE THE SOLE PROPERTY OF DESIGNER AND MAY NOT BEREPRODUCED OR MODIFIED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION.- CONTRACTORS TO CHECK ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO THECOMMENCEMENT OF ANY WORKS AND ANY DISCREPANCIES TO BE BROUGHT TO THEATTENTION OF THE SUPERVISOR.

© COPYRIGHT STATEMENTTHIS DESIGN AND / OR DRAWING IS CONFIDENTIAL AND SHALL REMAIN THE PROPERTYOF QUALITY DESIGN SOLUTIONS PTY LTD. IT MUST NOT BE REPRODUCED, COPIED ORALTERED WITHOUT THE APPROVAL OF QUALITY DESIGN SOLUTIONS PTY LTD.

1:100, 1:20 (A1)

ISSUED FOR BUILDING APPROVAL

A

C 04.08.19 Loading dock roof and electrical amendments

D xx.xx.xx -

Email: [email protected] Mobile: 0403 165 270

C10

C10

C10

C10

C10

C10

C10

C10

C10

C10

C10

C10

C9

11,59

378

7

TBC

12,38

0

ROOF LINE TO START WITHIN150mm OF THE TOP OF PANEL

REFER TO ENGINEERINGFOR FOOTING SET-DOWNS

220mm THICK CONCRETE TILTPANELS TO BOUNDARY

SELECTED COLORBOND CAPPING WITHZINCALUME FLASHING FIXED TOCONCRETE PANEL AND STEEL FRAMES

FFL 19.19

TOW 31.570

PJ

TOW 30.783

PJPJPJPJPJPJPJPJPJPJPJPJ

ROOF SHEETING TO BE TRIMDECK OR SIMILARWITH 55mm ANTICON SUPPORTED WITH 300mm x150mm x 2.0mm SAFETY WIRE AT 3° PITCH UNO.

TYPICAL SKYLIGHT - FGW TOPGLASS GC TRANSLUCENT SHEETING. SAFETYWIRE 300mm x 150mm x 2.0mm TO THE UNDERSIDE AS PER AS 1562.3:1996CLAUSE 2.4.3. SKYLIGHT LOCATIONS TO SUIT RACKING LAYOUTS

C10

C10

C10

C10

C10

C10

C10

C10

C10

C10

C10

C10

TBC

12,38

0

11,43

794

3

TBC

11,59

378

7

ROOF LINE TO START WITHIN 2540mmOF THE TOP OF LOADING DOCK PANEL

REFER TO ENGINEERINGFOR FOOTING SET-DOWNS

220mm THICK CONCRETE TILTPANELS TO BOUNDARY

SELECTED COLORBOND CAPPING WITHZINCALUME FLASHING FIXED TOCONCRETE PANEL AND STEEL FRAMES

LINE OF WALL BEHINDLINE OF WALL BEHIND

ROOF SHEETING TO RUNOVER TOP OF PANEL

FFL 19.19

TOW 31.570

TOW 30.627

PJPJPJPJPJPJPJPJPJPJPJ

ROOF SHEETING TO BE TRIMDECK OR SIMILARWITH 55mm ANTICON SUPPORTED WITH 300mm x150mm x 2.0mm SAFETY WIRE AT 3° PITCH UNO.

FIRE WALL

D01

D02

D03

D04

D05D

08D09

W01

W02

C2

C1

C3

C5

C1

C1

C1

C4

C4

C4

C4

C9

C5

C6

C6

C6

C6

C6

C2

C1

C3

C2

C1

C3

11,39

398

7

12,38

0

2,500

405,9

6040

2,000

4081

3

2,870

7,393

4,000

987

6,000

5,393

ROOF LINE TO START WITHIN150mm OF THE TOP OF PANEL

REFER TO ENGINEERINGFOR FOOTING SET-DOWNS

SELECTED COLORBOND CAPPING WITHZINCALUME FLASHING FIXED TOCONCRETE PANEL AND STEEL FRAMES

300mm THICKCONCRETE TILT PANEL

300mm THICKCONCRETE TILT PANEL

STEEL CANOPY REFER TO ENGINEERS DETAILS

EXPOSED CANOPY RAFTERREFER TO ENGINEERS DETAILS

40 x 10mm DEEP RECESS200mm x 200mm DEEP (MIN. DEPTH) COLORBOND EAVES GUTTER WITH 150mm x150mm COLORBOND DOWNPIPES. DOWNPIPES TO RUN ONTO CANOPY ROOF BELOW

PJ FFL 19.19

TOW 31.570

PJPJ PJ PJ PJ

TAPBOL

DP

BOLBOLBOLBOLBOLBOL

TOW 30.583

DPDPDP

BOLTAP

DP

DPBOL

DPDP

TOP OF CEILING LID

AUTOMATIC ROLLER SHUTTER

220mmCONCRETE

PANEL

AUTOMATIC ROLLER SHUTTERAUTOMATIC ROLLER SHUTTERAUTOMATIC DOCKLEVELLER ROLLER

SHUTTER

AUTOMATIC DOCKLEVELLER ROLLER

SHUTTER

220mmCONCRETE

PANEL

220mmCONCRETE

PANEL

220mmCONCRETE

PANEL

220mmCONCRETE

PANEL

220mmCONCRETE

PANEL

ROOF SHEETING TO BE TRIMDECK OR SIMILARWITH 55mm ANTICON SUPPORTED WITH 300mm x150mm x 2.0mm SAFETY WIRE AT 3° PITCH UNO.

TYPICAL SKYLIGHT - FGW TOPGLASS GC TRANSLUCENT SHEETING. SAFETYWIRE 300mm x 150mm x 2.0mm TO THE UNDERSIDE AS PER AS 1562.3:1996CLAUSE 2.4.3. SKYLIGHT LOCATIONS TO SUIT RACKING LAYOUTS

METAL CLADDING FIXED TO GIRTS

BOL

40

10

CONCRETETILT PANEL

D08

D09

C6

C6

C2

C1

C3

13,68

0

1,300

12,38

0

1,300

2,500

405,9

6040

2,000

401,4

88

REFER TO ENGINEERINGFOR FOOTING SET-DOWNS

SELECTED COLORBOND CAPPING WITHZINCALUME FLASHING FIXED TOCONCRETE PANEL AND STEEL FRAMES

40 x 10mmDEEP RECESS

DOCK LEVELLER RECESSED PITS. REFER TOMANUFACTURERS SPECIFICATION AND DETAILS

FFL 19.19

TOW 31.570

PJ

AUTOMATIC DOCKLEVELLER ROLLER

SHUTTER

AUTOMATIC DOCKLEVELLER ROLLER

SHUTTER

220mmCONCRETE

PANEL

220mmCONCRETE

PANEL

PJ

LOWER ROOF SHEETING TO BE TRIMDECK OR SIMILARWITH 55mm ANTICON SUPPORTED WITH 300mm x150mm x 2.0mm SAFETY WIRE AT 3° PITCH UNO.

C2

C1

C3

11,43

794

3

12,38

0

2,500

405,9

6040

2,000

4085

7

1,300

12,38

0

ROOF LINE TO START WITHIN 2540mmOF THE TOP OF LOADING DOCK PANEL

REFER TO ENGINEERINGFOR FOOTING SET-DOWNS

CONCRETE SLAB TO LOADING DOCKRAMP. REFER TO ENGINEERS DETAILS

40 x 10mmDEEP RECESS

600mm x 150mm DEEP (MIN. DEPTH)COLORBOND BOXED GUTTER WITH⌀150mm PVC DOWNPIPE

METAL CLADDINGFIXED TO GIRTS

FFL 19.19

TOW 31.570

TOW 30.627

PJPJ PJ PJ PJ PJ

DPBOL

220mmCONCRETE

PANELS

PJ

LOWER ROOF SHEETING TO BE TRIMDECKOR SIMILAR WITH 55mm ANTICONSUPPORTED WITH 300mm x 150mm x 2.0mmSAFETY WIRE AT 3° PITCH UNO.

ROOF SHEETING TO RUN OVER TOP OF PANEL

Elevation 31:100

Elevation 21:100

Elevation 11:100

Recess Detail1:20

Elevation 51:100

Elevation 61:100

ALL CONTRACTORS WORKING ON THIS PROJECT TOCHECK ALL DIMENSIONS AND NOTES PRIOR TOINITIATING ANY WORKS. ALL DISCREPANCIES TO BENOTIFIED TO THE PROJECT MANAGER STRAIGHT AWAY.

ELEVATION NOTES:- REFER TO ROOF PLAN FOR ALL ROOF INFORMATION ON A4.- REFER TO DOOR AND WINDOW SCHEDULE FOR INFORMATION ON A8.- ALL TOPS OF PANELS TO HAVE SELECTED COLORBOND CAPPING.- ROOF LINE TO START WITHIN 150mm BELOW THE TOP OF PANEL UNO.- ROOF SHEETING TO BE TRIMDEK OR SIMILAR WITH 55mm ANTICON SUPPORTED WITH 300mm x 150mm x 2.0mm SAFETY WIRE AT 3° PITCH UNO.- REFER TO ENERGY REPORT FOR DETAILS ON GLASS RATINGS.

NOTES:- THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATIONS, REPORTS, CONTRACTS AND DRAWINGS.- ALL BUILDING WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE REQUIRED AUSTRALIA STANDARDS AND THE NCC.- ALL DIMENSIONS TAKEN TO STRUCTURAL SURFACES UNLESS OTHERWISE NOTED (STUD FRAMING / CONCRETE PANELS ETC).NO ALLOWANCE FOR INTERNAL AND EXTERNAL SHEETING. ANY DISCREPANCY CONFIRM WITH OWNER OR BUILDER.- CARE SHOULD BE TAKEN TO INCLUDE AN ALLOWANCE IN CALCULATION OF CLEARANCE REQUIRED FOR FIXINGS ETC.

ABREVIATIONS:- FE = FIRE EXTINGUISHER.- FHR = FIRE HOSE REEL.- COL = COLUMN.- DP = DOWNPIPE.- PJ = PANEL JOINT.

MATERIALS - COLOURS TO BE CONFIRMED:C/1 - FEATURE CONCRETE WALLS - PAINT FINISH LOW SHEEN - 'PMS 433c'C/2 - RECESS LINES - PAINT FINISH LOW SHEEN - 'AS2700 COLOUR X15 ORANGE'C/3 - MAIN CONCRETE WALLS - PAINT FINISH LOW SHEEN - DULUX 'KNIGHTS OF THE REALM'C/4 - METAL CLADDING - COLORBOND CUSTOM-ORB - 'SHALE GREY - TBC'C/5 - EXPOSED STEEL - PAINT /POWDERCOAT - 'WINDSPRAY - TBC'C/6 - ROLLER DOORS / PA DOORS - PAINT /POWDERCOAT - 'WINDSPRAY - TBC'C/7 - ALUM. WINDOWS / DOOR FRAMES - POWDERCOAT - 'SHALE GREY - TBC'C/8 - DOWNPIPES / GUTTERS - PAINT /POWDERCOAT - 'WINDSPRAY - TBC'C/9 - ROOF SHEETING - ZINCALUMEC/10 - BOUNDARY CONCRETE PANELS - NATURAL FINISH

Page 6: ISSUED FOR BUILDING APPROVAL · DATE OF ISSUE: SCALE: DRAWN: REVISDIAOTNEDESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan

DATE OF ISSUE:

SCALE:

DRAWN:

REVISION DATE DESCRIPTION

Lot 32 #18 Casino Street Welshpool

Client:

Project Title:

Alita Constructions

Elevation & Sections01.05.19

MB

Project Number:

1922Drawing Number:

A6

B

08.05.19

14.07.19

Preliminary Issue for Client Comments

Issued for consultants and building approval

PO Box 2655, Malaga WA 6944

GENERAL NOTES:- DO NOT SCALE FROM DRAWINGS.- THESE PLANS ARE THE SOLE PROPERTY OF DESIGNER AND MAY NOT BEREPRODUCED OR MODIFIED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION.- CONTRACTORS TO CHECK ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO THECOMMENCEMENT OF ANY WORKS AND ANY DISCREPANCIES TO BE BROUGHT TO THEATTENTION OF THE SUPERVISOR.

© COPYRIGHT STATEMENTTHIS DESIGN AND / OR DRAWING IS CONFIDENTIAL AND SHALL REMAIN THE PROPERTYOF QUALITY DESIGN SOLUTIONS PTY LTD. IT MUST NOT BE REPRODUCED, COPIED ORALTERED WITHOUT THE APPROVAL OF QUALITY DESIGN SOLUTIONS PTY LTD.

1:100 (A1)

ISSUED FOR BUILDING APPROVAL

A

C 04.08.19 Loading dock roof and electrical amendments

D xx.xx.xx -

Email: [email protected] Mobile: 0403 165 270

C2

C1

C3

9,000

1,836

790

510

11,59

378

7

1,300

12,38

0

TBC

10,83

675

7

2,870

2,500

405,9

6040

2,000

4081

3

7,054

545

3,794

11,39

398

7

ROOF LINE TO START WITHIN 2540mmOF THE TOP OF LOADING DOCK PANEL

REFER TO ENGINEERINGFOR FOOTING STEP DOWNS

CONCRETE SLAB TO LOADING DOCKRAMP. REFER TO ENGINEERS DETAILS

40 x 10mm DEEP RECESS

METAL CLADDING FIXED TO GIRTS

200mm x 200mm DEEP (MIN. DEPTH) COLORBOND EAVESGUTTER WITH 150mm x 150mm COLORBOND DOWNPIPES.DOWNPIPES TO RUN ONTO CANOPY ROOF BELOW

SELECTED COLORBOND CAPPING WITHZINCALUME FLASHING FIXED TOCONCRETE PANEL AND STEEL FRAMES

EXPOSED CANOPY RAFTERREFER TO ENGINEERS DETAILS

600mm x 150mm DEEP (MIN. DEPTH) 0.55mmTHICK ZINCALUME CANOPY BOX GUTTER

RAFTER REFER TOENGINEERS DETAILS

600mm x 150mm DEEP (MIN. DEPTH) 0.55mm THICK ZINCALUME BOXGUTTER ON SPANDEK ON 50mm WIDE GUTTER STRAPS WITH SADDLESAT MAX. 600mm CTRS. FALL GUTTER TO OUTLET AT MIN. 1:200

DOCK LEVELLER RECESSED PIT.REFER TO MANUFACTURERSSPECIFICATION AND DETAILS

600mm x 150mm DEEP (MIN. DEPTH)COLORBOND BOXED GUTTER WITH⌀150mm PVC DOWNPIPE

FFL 19.19PJPJPJPJPJPJTAP

BOL

220mm CONCRETE PANELS

TOP OF CEILING LID

FFL 19.19

DP

DP

TOW 31.570

TOW 31.570

FE

TOW 30.583

ROOF SHEETING TO RUN OVER TOP OF PANELLOWER ROOF SHEETING TO BE TRIMDECKOR SIMILAR WITH 55mm ANTICONSUPPORTED WITH 300mm x 150mm x2.0mm SAFETY WIRE AT 3° PITCH UNO.

150mm CONCRETE SLAB. REFERTO ENGINEERING DETAILS

9000mm HIGH RACKING

ROOF SHEETING TO RUN OVER TOP OF PANEL

CANOPY ROOF SHEETING TO BE TRIMDECKOR SIMILAR WITH 300mm x 150mm x 2.0mmSAFETY WIRE AT 3° PITCH UNO.

CONCRETE RETAINING TO LOADING DOCKRAMP. REFER TO ENGINEERING DETAILS

C2

C1

C3

9,000

1,693

11,59

378

7

TBC

12,38

0

2,500

405,8

54

8,393

10,69

390

0

REFER TO ENGINEERINGFOR FOOTING STEP DOWNS

ROOF LINE TO START WITHIN150mm OF THE TOP OF PANEL

40 x 10mmDEEP RECESS

200mm x 200mm DEEP (MIN. DEPTH) COLORBOND EAVESGUTTER WITH 150mm x 150mm COLORBOND DOWNPIPES.DOWNPIPES TO RUN ONTO CANOPY ROOF BELOW

SELECTED COLORBOND CAPPING WITHZINCALUME FLASHING FIXED TOCONCRETE PANEL AND STEEL FRAMES

EXPOSED CANOPY RAFTERREFER TO ENGINEERS DETAILS

600mm x 150mm DEEP (MIN. DEPTH) 0.55mmTHICK ZINCALUME CANOPY BOX GUTTER

ROOF TRUSS REFER TOENGINEERS DETAILS

600mm x 150mm DEEP (MIN. DEPTH) 0.55mm THICK ZINCALUME BOXGUTTER ON SPANDEK ON 50mm WIDE GUTTER STRAPS WITH SADDLESAT MAX. 600mm CTRS. FALL GUTTER TO OUTLET AT MIN. 1:200

FFL 19.19 PJ

DP

DP

TOW 31.570

TOW 31.570

PJ

220mm THICK CONCRETETILT PANELS TO BOUNDARY

PJPJPJPJPJPJPJPJ

FHRBOL BOL

DP

UT 29.883

COMPACTED FILL150mm CONCRETE SLAB. REFERTO ENGINEERING DETAILS 0.2 WATERPROOF MEMBRANE 9000mm HIGH RACKING

ROOF SHEETING TO RUNOVER TOP OF PANEL

ROOF SHEETING TO BE TRIMDECK ORSIMILAR WITH 55mm ANTICONSUPPORTED WITH 300mm x 150mm x2.0mm SAFETY WIRE AT 3° PITCH UNO.

CANOPY ROOF SHEETING TO BE TRIMDECK OR SIMILAR WITH300mm x 150mm x 2.0mm SAFETY WIRE AT 3° PITCH UNO.

150mm CONCRETE HARDSTAND.REFER TO ENGINEERING DETAILS

FIRE WALL FIRE WALLFIRE WALL

C10

C10

C10

C10

C10

C10

C10

C10

C10

C10

C10

C10

11,59

478

6

8,393

3,201

TBC

11,59

378

7

12,38

0

ROOF LINE TO START WITHIN150mm OF THE TOP OF PANEL

REFER TO ENGINEERINGFOR FOOTING SET-DOWNS

220mm THICK CONCRETE TILTPANELS TO BOUNDARY

SELECTED COLORBOND CAPPING WITHZINCALUME FLASHING FIXED TOCONCRETE PANEL AND STEEL FRAMES

LINE OF WALL BEHIND LINE OF WALL BEHIND

200mm x 200mm DEEP (MIN. DEPTH) COLORBOND EAVESGUTTER WITH 150mm x 150mm COLORBOND DOWNPIPE.DOWNPIPE TO RUN ONTO CANOPY ROOF BELOW

FFL 19.19

TOW 31.570

PJ PJ PJ PJ PJ PJ PJ PJ PJ PJ PJ

TOW 31.570

TOW 31.570

DP

ROOF SHEETING TO BE TRIMDECK OR SIMILARWITH 55mm ANTICON SUPPORTED WITH 300mm x150mm x 2.0mm SAFETY WIRE AT 3° PITCH UNO.

CANOPY ROOF BRACE BEHIND

CANOPY ROOF SHEETING TO BE TRIMDECKOR SIMILAR WITH 300mm x 150mm x 2.0mmSAFETY WIRE AT 3° PITCH UNO.

FIRE WALL FIRE WALL FIRE WALL

Section B1:100

Section A1:100

Elevation 41:100

ALL CONTRACTORS WORKING ON THIS PROJECT TO CHECK ALL DIMENSIONSAND NOTES PRIOR TO INITIATING ANY WORKS. ALL DISCREPANCIES TO BENOTIFIED TO THE PROJECT MANAGER STRAIGHT AWAY.

SECTION NOTES:- REFER TO ROOF PLAN FOR ALL ROOF AND DOWNPIPE INFORMATION ON A4.- REFER TO ELECTRICAL AND CEILING PLAN FOR INFORMATION ON A7.- REFER TO DOOR AND WINDOW SCHEDULE FOR INFORMATION ON A8.- ALL EXIT DOORS WITH ILLUMINATED SIGNS TO HAVE BRAILE SIGNAGE. INSTALL BRAILLE/TACTILE SIGNAGE ASPER NCC CLAUSE D3.6 AND IN ACCORDANCE WITH AS1428.1.- VENTILATION, AIR-CONDITIONING AND MECHANICAL SYSTEMS TO BE DESIGNED AND INSTALLED AS PER NCCAND AS1668.2. REFER TO ENERGY REPORT PARTS J5 AND J6.- REFER TO ENERGY REPORT FOR ALL ROOF, CEILING AND WALL INSULATION REQUIREMENTS.- AIR-CONDITIONING SYSTEMS TO BE CONFIRMED AT TENDER STAGE. ALLOWANCE TO BE MADE FOR TUNDISHAND LOCATION TO BE CONFIRMED ON SITE.- FIRE HOSE REEL'S TO COMPLY WITH AS2441 AND FIRE EXTINGUISHER'S TO COMPLY WITH AS2444 AND AS3745.- TIMBER WORKS SHALL COMPLY WITH THE LIGHT TIMBER FRAMING CODE AS1684.- TERMITE MANAGEMENT AS PER NCC CLAUSES B1.4 & F1.9 AND IN ACCORDANCE WITH AS3660 PART 1.- CONCRETE WORKS TO COMPLY WITH AS3600 AND MASONRY WORKS TO COMPLY WITH AS3700.

MATERIALS - COLOURS TO BE CONFIRMED:C/1 - FEATURE CONCRETE WALLS - PAINT FINISH LOW SHEEN - 'PMS 433c'C/2 - RECESS LINES - PAINT FINISH LOW SHEEN - 'AS2700 COLOUR X15 ORANGE'C/3 - MAIN CONCRETE WALLS - PAINT FINISH LOW SHEEN - DULUX 'KNIGHTS OF THE REALM'C/4 - METAL CLADDING - COLORBOND CUSTOM-ORB - 'SHALE GREY - TBC'C/5 - EXPOSED STEEL - PAINT /POWDERCOAT - 'WINDSPRAY - TBC'C/6 - ROLLER DOORS / PA DOORS - PAINT /POWDERCOAT - 'WINDSPRAY - TBC'C/7 - ALUM. WINDOWS / DOOR FRAMES - POWDERCOAT - 'SHALE GREY - TBC'C/8 - DOWNPIPES / GUTTERS - PAINT /POWDERCOAT - 'WINDSPRAY - TBC'C/9 - ROOF SHEETING - ZINCALUMEC/10 - BOUNDARY CONCRETE PANELS - NATURAL FINISH

NOTES:- THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATIONS, REPORTS, CONTRACTS AND DRAWINGS.- ALL BUILDING WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE REQUIRED AUSTRALIA STANDARDS AND THE NCC.- ALL DIMENSIONS TAKEN TO STRUCTURAL SURFACES UNLESS OTHERWISE NOTED (STUD FRAMING / CONCRETE PANELS ETC).NO ALLOWANCE FOR INTERNAL AND EXTERNAL SHEETING. ANY DISCREPANCY CONFIRM WITH OWNER OR BUILDER.- CARE SHOULD BE TAKEN TO INCLUDE AN ALLOWANCE IN CALCULATION OF CLEARANCE REQUIRED FOR FIXINGS ETC.

ABREVIATIONS:- FE = FIRE EXTINGUISHER.- FHR = FIRE HOSE REEL.- COL = COLUMN.- DP = DOWNPIPE.- PJ = PANEL JOINT.

ELEVATION NOTES:- REFER TO ROOF PLAN FOR ALL ROOF INFORMATION ON A4.- REFER TO DOOR AND WINDOW SCHEDULE FOR INFORMATION ON A8.- ALL TOPS OF PANELS TO HAVE SELECTED COLORBOND CAPPING.- ROOF LINE TO START WITHIN 150mm BELOW THE TOP OF PANEL UNO.- ROOF SHEETING TO BE TRIMDEK OR SIMILAR WITH 55mm ANTICONSUPPORTED WITH 300mm x 150mm x 2.0mm SAFETY WIRE AT 3° PITCH UNO.- REFER TO ENERGY REPORT FOR DETAILS ON GLASS RATINGS.

Page 7: ISSUED FOR BUILDING APPROVAL · DATE OF ISSUE: SCALE: DRAWN: REVISDIAOTNEDESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan

DATE OF ISSUE:

SCALE:

DRAWN:

REVISION DATE DESCRIPTION

Lot 32 #18 Casino Street Welshpool

Client:

Project Title:

Alita Constructions

Electrical & Ceiling Plans01.05.19

MB

Project Number:

1922Drawing Number:

A7

B

08.05.19

14.07.19

Preliminary Issue for Client Comments

Issued for consultants and building approval

PO Box 2655, Malaga WA 6944

GENERAL NOTES:- DO NOT SCALE FROM DRAWINGS.- THESE PLANS ARE THE SOLE PROPERTY OF DESIGNER AND MAY NOT BEREPRODUCED OR MODIFIED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION.- CONTRACTORS TO CHECK ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO THECOMMENCEMENT OF ANY WORKS AND ANY DISCREPANCIES TO BE BROUGHT TO THEATTENTION OF THE SUPERVISOR.

© COPYRIGHT STATEMENTTHIS DESIGN AND / OR DRAWING IS CONFIDENTIAL AND SHALL REMAIN THE PROPERTYOF QUALITY DESIGN SOLUTIONS PTY LTD. IT MUST NOT BE REPRODUCED, COPIED ORALTERED WITHOUT THE APPROVAL OF QUALITY DESIGN SOLUTIONS PTY LTD.

1:100, 1:0.67 (A1)

ISSUED FOR BUILDING APPROVAL

A

C 04.08.19 Loading dock roof and electrical amendments

D xx.xx.xx -

Email: [email protected] Mobile: 0403 165 270

FW

SP

OO

N D

RA

IN

HWU 20A

1500 1200

6200

6200

6200

3200

1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

1200

3200

2500mm x 4500mm REFUSE BIN AREA TBC

PRELAYS ONLY FORFUTURE KITCHENETTE

LINE OF TIMBER FRAME CEILING LID ABOVE

ELECTRICAL DISTRIBUTION AND PCDBOARDS AND SITE TEMPORARY POWER

2500mm HIGH FLUSH CEILING TO OFFICE WITH R2.1INSULATION. REFER TO ENERGY REPORT FOR DETAILS

2500mm HIGH FLUSHCEILING TO TOILET

ELECTRICAL AND COMMUNICATIONPRELAYS TO BE CONFIRMED ON SITE

150 PVC FLUME TOEXTERNAL AIR BYROOFER

SEPTIC SYSTEM PUMP CASTED INTO IN HARDSTAND WITHINSPECTION LID AND POWER, LOCATION TO BE CONFIRMED ON SITE

REFER TO DOCK LEVELLER MANUFACTURERSSPECIFICATIONS AND DETAILS FORCONDUITS, POWER AND ISOLATORS

FE

PROPOSED WAREHOUSEFFL: 19.19

A: 1,141.29m2

PROPOSED LOADING DOCKA: 160.74m2

TAP

TAP

FHR

FHR

NOTE:ALL PLACEMENTS OF FITTINGS SHOWNINDICATIVE, LOCATIONS TO BE CONFIRMEDON SITE PRIOR TO INSTALLATION

FE

24m

JUMBO 40m

JUMBO 40m

JUMBO 40m

JUMBO 40m

JUMBO 40m

SPLIT SYSTEM TO BE CONFIRMED AT TENDERSTAGE. TUNDISH THROUGH EXTERNAL WALL

BOL

BOL

BOL

BOL

BOL

BOL

BOL

BOL

BOL

BOL

DP

DP

DP

DP

DP

DP

DP

DP

DP

DP

DP

DP

ELECTRICAL LEGENDDescription

10A DOUBLE GPO @ 1200

10A DOUBLE GPO @ 1500

10A DOUBLE GPO @ 300

10A DOUBLE WP GPO @ 1200

10A SINGLE WP GPO FOR SEPTIC SYSTEM PUMP @ LOCATION TBC

13W LED DOWNLIGHT

13W LED WALL LIGHT - THORN LARA

150W LED HIGHBAY

2.5kW SPLIT SYSTEM

200W LED HIGHBAY

20A SINGLE PHASE AIR-CON ISOLATOR - HEIGHT & LOCATION TBC

3 PHASE 20A HWU

3PHASE DOCK LEVELLER GPO @ LOCATION TBC

3PHASE DOCK LEVELLER ISOLATOR SWITCH @ LOCATION TBC

3PHASE FORKLIFT CHARGING POINT WITH ISOLATOR @ 1200

3PHASE SINGLE ROLLER SHUTTER GPO @ 3200

3PHASE SINGLE ROLLER SHUTTER GPO @ 6200

DOCK LEVELLER CONTROL SWITCH

DOUBLE DATA / SINGLE PHONE @ 300

ELECTRICAL DISTRIBUTION BOARD

EXHUAST FAN W/10A CONNECTION

LIGHT SWITCH

LOADING BAY DOOR BELL

MOTION SENSOR

NBN PCD BOX

RECESSED MOUNTED EMERGENCY LIGHT - CLIFE

SECURITY CAMERA

SURFACE MOUNTED LED BATTEN

SURFACE MOUNTED EMERGENCY LIGHT - CLEVERTRONICS CLIFE-PRO-SMS

TEMPORARY POWER 10A DOUBLE WP GPO @ 1200

Symbol Qty11

1

2

1

1

5

3

5

1

21

1

1

2

2

2

2

3

2

2

1

1

4

1

1

1

2

14

3

6

1

NORTH

S UMM

E RS

UN

SU

N

W ITN

E RH

OT

DRYWINDS

PREVAILING

WIND

&R

AIN

Electrical & Ceiling Plan1:100

ELECTRICAL & CEILING NOTES:- TELSTRA PIT & POWER DOME POSITIONS TO BE CONFIRMED ON SITE. CONDUIT RUNS ARE INDICATIVE ONLY, CONTRACTOR TO CONFIRM ON SITE.- NBN CURRENTLY NOT AVAILABLE (PROPOSED FTTC), DEVELOPMENT MUST COMPLY WITH NBN STANDARDS.- POWER AND COMMUNICATION SERVICES LOCATIONS TO BE CONFIRMED ON SITE AND APPLICATIONS BY OWNER AND BUILDER.- ELECTRICAL AND AIR CONDITIONING CONTRACTORS TO PLACES SERVICES IN CEILINGS AND CAVITIES AND NOT SURFACE MOUNTED DUCTING.- ALL HOT WATER SUPPLY SYSTEMS ARE REQUIRED TO BE INSTALLED IN ACCORDANCE WITH SECTION 8 OF AS3500.4.- MECHANICAL VENTILATION AND AIR-CONDITIONING SYSTEM INSTALLED TO PROVIDE VENTILATION IN ACCORDANCE WITH NCC VOLUME 1 ARE TO BE COMPLIANT WITH AS1668.2 & AS/NZS 3666.1.- ARTIFICIAL LIGHTING TO BE DESIGNED AND INSTALLED IN ACCORDANCE WITH PARTS J5 & J6 OF THE NCC VOLUME 1 REQUIREMENTS FOR ENERGY EFFICIENCY.- REFER TO ENERGY REPORT FOR ALL ROOF, CEILING AND WALL INSULATION REQUIREMENTS.- AIR-CONDITIONING SYSTEMS TO BE CONFIRMED AT TENDER STAGE. ALLOWANCE TO BE MADE FOR TUNDISH AND LOCATION TO BE CONFIRMED ON SITE.- SECURITY CAMERAS AND ALARM SYSTEM TO BE DESIGNED BY CONTRACTOR AND CONFIRMED AT TENDER STAGE.

NOTES:- THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATIONS, REPORTS, CONTRACTS AND DRAWINGS.- ALL BUILDING WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE REQUIRED AUSTRALIA STANDARDS AND THE NCC.- ALL DIMENSIONS TAKEN TO STRUCTURAL SURFACES UNLESS OTHERWISE NOTED (STUD FRAMING / CONCRETE PANELS ETC). NOALLOWANCE FOR INTERNAL AND EXTERNAL SHEETING. ANY DISCREPANCY CONFIRM WITH OWNER OR BUILDER.- CARE SHOULD BE TAKEN TO INCLUDE AN ALLOWANCE IN CALCULATION OF CLEARANCE REQUIRED FOR FIXINGS ETC.

ABREVIATIONS:- FE = FIRE EXTINGUISHER.- FHR = FIRE HOSE REEL.- COL = COLUMN.- DP = DOWNPIPE.- PJ = PANEL JOINT.

ALL CONTRACTORS WORKING ON THIS PROJECT TO CHECK ALL DIMENSIONSAND NOTES PRIOR TO INITIATING ANY WORKS. ALL DISCREPANCIES TO BENOTIFIED TO THE PROJECT MANAGER STRAIGHT AWAY.

Page 8: ISSUED FOR BUILDING APPROVAL · DATE OF ISSUE: SCALE: DRAWN: REVISDIAOTNEDESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan

DATE OF ISSUE:

SCALE:

DRAWN:

REVISION DATE DESCRIPTION

Lot 32 #18 Casino Street Welshpool

Client:

Project Title:

Alita Constructions

Amenities Layouts & Door/Window Schedules01.05.19

MB

Project Number:

1922Drawing Number:

A8

B

08.05.19

14.07.19

Preliminary Issue for Client Comments

Issued for consultants and building approval

PO Box 2655, Malaga WA 6944

GENERAL NOTES:- DO NOT SCALE FROM DRAWINGS.- THESE PLANS ARE THE SOLE PROPERTY OF DESIGNER AND MAY NOT BEREPRODUCED OR MODIFIED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION.- CONTRACTORS TO CHECK ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO THECOMMENCEMENT OF ANY WORKS AND ANY DISCREPANCIES TO BE BROUGHT TO THEATTENTION OF THE SUPERVISOR.

© COPYRIGHT STATEMENTTHIS DESIGN AND / OR DRAWING IS CONFIDENTIAL AND SHALL REMAIN THE PROPERTYOF QUALITY DESIGN SOLUTIONS PTY LTD. IT MUST NOT BE REPRODUCED, COPIED ORALTERED WITHOUT THE APPROVAL OF QUALITY DESIGN SOLUTIONS PTY LTD.

1:50, 1:30, 1:1 (A1)

ISSUED FOR BUILDING APPROVAL

A

C 04.08.19 Loading dock roof and electrical amendments

D xx.xx.xx -

Email: [email protected] Mobile: 0403 165 270

1000

500 MIN

OBSTRUCTION OR INTERNAL CORNER

TACTILE EXIT SIGN AS PER NCC& AS1428.1 2009

NOTES:- ALL DOOR HANDLES TO BE INSTALLED IN ACCORDANCE WITH SECTION13 OF AS 1428.1 (PART 1) AND BE COMPLIANT WITH D2.21 OF THE NCC- REFER TO SPECIFICATION FOR INFORMATION ON DOOR HARDWARE- ALL SWITCHES & CONTROLS ARE REQUIRED TO BE INSTALLED INACCORDANCE WITH SECTION 14 OF AS 1428.1 (PART 1)

400 MAX PAN

450 - 460 CTR PAN

350 - 400 BACKREST

460 - 480

120 - 150

150 - 200

700 M

AX

300 MAX

800 +/- 10

600 MIN

150 -

200

SIDE WALL REAR WALL

BACKREST POSITION 0 - 50FROM SEAT BOLT HOLE

FRONT OF ANY BACK WALL MOUNTED FIXTUREOF OBSTRUCTION EXCEPT BACKRESTANGLE OF FRONT OF

BACKREST

ZONE FOR POSITION OF TOILETPAPER DISPENSER OUTLET

FRONT OF BACKREST

95° TO 100°

BACKREST NOTES:- TO BE CAPABLE OF WITHSTANDING A FORCE IN ANY DIRECTION OF 1100 N- TO HAVE A HEIGHT, AT THE LOWER EDGE OF BACKREST TO THE TOP OF THEWC SEAT, OF 120mm TO 150mm- TO HAVE A VERTICAL HEIGHT OF 150 - 200mm AND A WIDTH OF 350 - 400mm- THE FRONT EDGE OF THE CENTRE OF THE BACKREST BE POSITIONED TOACHIEVE AN ANGLE OF BETWEEN 95° TO 100° BACK FROM THE SEAT HINGE

TOP OF SEAT

ID D01 D02 D03 D04 D05 D06 D07 D08 D09

2D Symbol D01

D02 D03 D04

D05

D06

D07

D08 D09

Elevation

Leaf Dimensions 920×2,050 5,500×6,000 5,500×6,000 5,500×6,000 920×2,050 920×2,040 920×2,040 2,400×3,000 2,400×3,000

Wallhole Dimensions 1,020×2,100 5,500×6,000 5,500×6,000 5,500×6,000 1,020×2,100 1,020×2,090 1,020×2,090 2,400×3,000 2,400×3,000

Quantity 1 1 1 1 1 1 1 1 1

Operation Auto Roller Shutter Auto Roller Shutter Auto Roller Shutter Dock Leveler Auto Roller Shutter Auto Roller Shutter

Frame Type & Finish

Wall Type

Glazing Type

Notes

Door List

ID W01 W02

Elevation

Wallhole Dimensions 1,900×1,200 1,900×1,200

Nominal Sill Height 900 900

Quantity 1 1

Operation Fixed Window Fixed Window

Frame Type & FinishCommercial AluminiumFrame Powdercoated -

Colour Black TBC

Commercial AluminiumFrame Powdercoated -

Colour Black TBC

Wall Type Concrete Panel Concrete Panel

Glazing Type Refer to Energy Report Refer to Energy Report

Notes

Window List

FW

2xHOOKS

123

76 1,270 76 2,780 76

902,1

1076

584

76

425

1,675

10

10 300 1,430 980GRABRAIL

50 10

1,960 800FIXTURE

460 2,300WC CIRCULATION SPACE

455

1,645

10

795

300

1,005

902,1

1076

660

2,936

1,900

WC

CIRC

ULAT

ION

SPAC

E20

0

SHELF

SELECTED CERAMIC PAN & CISTERN

PORTABLE SANITARY DISPOSAL UNIT BY OWNER

⌀32 GRABRAIL M.S. SATIN CHROME FINISH

PRELAYS ONLY FOR FUTURE KITCHENETTE

TILED

ACCESSIBLE TOILETTO COMPLY WITH

AS1428.1.2009 SELECTEDCERAMIC BASIN

650

800

100

900

950

2,500

SELECTED SKIRTING TILE

SELECTED BASIN WITH MIRROR

SHELF

2,500

1,400

800

600

460

200

800

800

SELECTED SKIRTING TILE

⌀32 GRABRAIL M.S.SATIN CHROME FINISH

SELECTED CERAMIC PAN &CISTERN WITH BACKREST

SELECTED BASIN WITH MIRROR

795300980

2,500

800

600

SELECTED SKIRTING TILE

⌀32 GRABRAIL M.S.SATIN CHROME FINISH

BACKREST INSTALLED ASPER AS1428.1.2009 15.2.4

SELECTED CERAMIC PAN &CISTERN WITH BACKREST

Switch & Handle Detail1:50

Accessible Toilet Installation Detail1:30

Unisex Accessible1:50

View D-31:50

View D-21:50

View D-11:50

ACCESSIBLE TOILET NOTES:- COMPLIANCE WITH SECTION 15 AS1428.1-2009 AND PART F2.4 OF NCC.- DOORS TO BE PROVIDED WITH AN IN USE INDICATOR AND SHALL BE OPENABLE FROM THE OUTSIDE.- ALL DOORS TO HAVE A MINIMUM LUMINANCE OF 30 % FROM THE ADJOINING WALLS.- ALL LIGHT SWITCHES TO BE INSTALLED NO HIGHER THAN 1m FROM THE F.F.L.- 200 x 200mm NON-SLIP FLOOR TILES WITH 1 ROW OF SKIRTING UNO.- ACCESSIBLE WC TO COMPLY WITH A.S 1428.1 TILED FLOOR WITH FALL TO WASTE CATCH.- ACCESSIBLE TOILET TO HAVE A CLOTHES-HANGING DEVICE / HOOK INSTALLED AS PER AS 1428.1 - 2009 SECTION 15.4.4. HOOK TO BE INSTALLED 1200mm TO 1350mmABOVE THE F.F.L AND NOT LESS THEN 500mm OUT FROM ANY INTERNAL CORNER.- GRABRAILS TO COMPLY WITH AS 1428.1 (TYP). THE CROSS SECTION OF HANDRAILS SHALL BE CIRCULAR, NOT LESS THAN 30mm NO MORE THAN 50mm IN DIAMETER.- ALL ACCESSIBLE TOILETS TO HAVE A BACKREST 395mm x 190mm INSTALLED 150mm FROM TOP OF SEAT AS PER A.S 1428.1 - 2009 SECTION 15.2.4.- ALL BASINS TO HAVE 1 ROW OF SPLASHBACK TILES ABOVE THE SINK.- BASIN IN ACCESSIBLE TOILET TO HAVE A 600mm WIDE x 900mm HIGH MIRROR TO INSTALLED 900mm FROM F.F.L DIRECTLY OVER THE SINK.- WATER TAPS TO HAVE LEVEL HANDLES WITH CLEARANCE OF 50mm FROM ADJACENT SURFACES. HOT AND COLD WATER THROUGH ONE SPOUT ONLY.- PLUMBER TO ALLOW FOR FIXING FOR TOILET SYSTEM , BASINS AND TOILET ROLL HOLDER TYPICAL.- THE CEILING HEIGHT IS TO BE 2500mm HIGH UNO.- WC SEAT TO HAVE A MINIMUM LUMINANCE OF 30% FROM THE FLOOR FINISH COLOUR.- NO HORIZONTAL CHASING FOR PLUMBING TO LOAD BEARING BRICKWORK, CHASING TO BE INSTALLED VERTICALLY.- THE EXHAUST FAN WILL BE INSTALLED IN A LOCATION THAT WILL ALLOW ACCESS FOR THE PLUMBER TO INSTALL THE EXHAUST STACK.- TOILET PAPER HOLDER ZONE AS PER SECTION 15.2.6 of AS1428.1-2009.- FLUSHING CONTROL ZONE AS PER SECTION 15.2.5 of AS 1428.1 - 2009.

ALL CONTRACTORS WORKING ON THIS PROJECT TO CHECK ALL DIMENSIONSAND NOTES PRIOR TO INITIATING ANY WORKS. ALL DISCREPANCIES TO BENOTIFIED TO THE PROJECT MANAGER STRAIGHT AWAY.

AMENITIES DOOR SIGNAGE NOTE:- SIGNAGE PANELS ARE TO BE INSTALLED BETWEEN 1200mm - 1600mm FROMFINISHED FLOOR LEVEL AND LOCATED ON THE WALL LATCH SIDE OF THE DOOR(50mm MIN. TO 300mm MAX AWAY FROM THE DOOR FRAME. IF THIS CAN'T BEACHIEVED THE SIGN MUST BE PLACED ON THE DOOR AT THE REQUIRED HEIGHT.

SCHEDULE NOTES:- ALL DOOR HANDLES AND CONTROLS TO BE IN ACCORDANCE WITH AS1428.1 CLAUSE 13.5.- ALL DOOR FURNITURE IN PATH OF EXIT BEING OPENABLE WITOUT A KEY AND A SINGLE DOWARD ACTION ON A DEVICE LOCATED BETWEEN 900 AND 1100 AFL.GLAZING TO BE INSTALLED AS PER THE PART J2 GLAZING PART OF THE ENERGY EFFICIENCY REPORT. THIS REPORT CANBE OBTAINED FROM THE BUILDER.- FORCE REQUIREMENTS FOR ALL DOORS TO BE IN ACCORDANCE WITH AS1428.1 CLAUSE 13.5.2 (e)- MAX 20N FORCE TO OPEN, CLOSE OR HOLD OPEN A DOOR.- ANY HINGED DOORS WITH CLOSERS SHOULD BE ADJUSTABLE CLOSERS, COMPATIBLE WITH THE DOOR TO ENSURE THE FORCE TO OPEN THE DOOR DOES NOT EXCEED 20N.- ALL PAINTED FRAMES TO BE 50% TINT STRENGTH OF CORRESPONDING NOMINATED WALL COLOUR ( TO ENSURE MIN 30% LUMINANCE CONTRAST IN ACCORDANCE WITH AS1428.1 CLAUSE 13.1).- ALL DOORS TO SANITARY COMPARTMENTS TO BE READILY REMOVABLE FROM THE OUTSIDE WITH LIFT OFF HINGES.- ALL DOOR SWINGS TO BE CHECKED AND CONFIRMED PRIOR TO ORDERING.- PLEASE REFER TO SPECIFICATIONS FOR ADDITIONAL INFORMATION.

NOTES:- THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATIONS, REPORTS, CONTRACTS AND DRAWINGS.- ALL BUILDING WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE REQUIRED AUSTRALIA STANDARDS AND THE NCC.- ALL DIMENSIONS TAKEN TO STRUCTURAL SURFACES UNLESS OTHERWISE NOTED (STUD FRAMING / CONCRETE PANELS ETC). NOALLOWANCE FOR INTERNAL AND EXTERNAL SHEETING. ANY DISCREPANCY CONFIRM WITH OWNER OR BUILDER.- CARE SHOULD BE TAKEN TO INCLUDE AN ALLOWANCE IN CALCULATION OF CLEARANCE REQUIRED FOR FIXINGS ETC.

ABREVIATIONS:- FE = FIRE EXTINGUISHER.- FHR = FIRE HOSE REEL.- COL = COLUMN.- DP = DOWNPIPE.- PJ = PANEL JOINT.

Auto Roller ShutterAuto Roller ShutterAuto Roller Shutter Exit Single Swing Door Single Swing Door - WCSingle Swing DoorExit Single Swing Door

Galvanised Pressed Metal- Colour Windspray TBC Powdercoated - Colour Windspray TBC Powdercoated - Colour Windspray TBC Powdercoated - Colour Windspray TBC Galvanised Pressed Metal

- Colour Windspray TBCGalvanised Pressed Metal

- Colour TBCGalvanised Pressed Metal

- Colour TBCPowdercoated - Colour

Windspray TBCPowdercoated - Colour

Windspray TBC

Dock Leveller Auto Roller Shutter Dock Leveller Auto Roller Shutter

Concrete Panel Concrete Panel Concrete Panel Concrete Panel Concrete Panel Stud Wall Stud Wall Concrete Panel Concrete Panel

N/A N/A N/A N/A N/A N/A N/A N/A N/A

Solid Core with S.S.Kickplate. Compliant

Lockable Door Hardwarewith Push Plates

Solid Core with S.S.Kickplate and Lift-off Hinges.

Compliant Lockable DoorHardware with Push Plates

and Self-closing Device

Solid Core with MetalCladding. Compliant

Lockable Door Hardwarewith Lock Cover Plate and

Self-closing Device

Solid Core with MetalCladding. Compliant

Lockable Door Hardwarewith Lock Cover Plate and

Self-closing Device

Roller Shutters to be 1.0mm BMT withElectric Motor and Chain. Wind Locks

Required.

Roller Shutters to be 1.0mm BMT withElectric Motor and Chain. Wind Locks

Required.

Roller Shutters to be 1.0mm BMT withElectric Motor and Chain. Wind Locks

Required.

Refer to Dock Leveller Specification Refer to Dock Leveller Specification

Page 9: ISSUED FOR BUILDING APPROVAL · DATE OF ISSUE: SCALE: DRAWN: REVISDIAOTNEDESCRIPTION Lot 32 #18 Casino Street Welshpool Client: Project Title: Alita Constructions Site Survey Plan

DATE OF ISSUE:

SCALE:

DRAWN:

REVISION DATE DESCRIPTION

Lot 32 #18 Casino Street Welshpool

Client:

Project Title:

Alita Constructions

DFES Plan01.05.19

MB

Project Number:

1922Drawing Number:

A9

B

08.05.19

14.07.19

Preliminary Issue for Client Comments

Issued for consultants and building approval

PO Box 2655, Malaga WA 6944

GENERAL NOTES:- DO NOT SCALE FROM DRAWINGS.- THESE PLANS ARE THE SOLE PROPERTY OF DESIGNER AND MAY NOT BEREPRODUCED OR MODIFIED IN WHOLE OR IN PART WITHOUT WRITTEN PERMISSION.- CONTRACTORS TO CHECK ALL DIMENSIONS AND CONDITIONS ON SITE PRIOR TO THECOMMENCEMENT OF ANY WORKS AND ANY DISCREPANCIES TO BE BROUGHT TO THEATTENTION OF THE SUPERVISOR.

© COPYRIGHT STATEMENTTHIS DESIGN AND / OR DRAWING IS CONFIDENTIAL AND SHALL REMAIN THE PROPERTYOF QUALITY DESIGN SOLUTIONS PTY LTD. IT MUST NOT BE REPRODUCED, COPIED ORALTERED WITHOUT THE APPROVAL OF QUALITY DESIGN SOLUTIONS PTY LTD.

1:250 (A1)

ISSUED FOR BUILDING APPROVAL

A

C 04.08.19 Loading dock roof and electrical amendments

D xx.xx.xx -

Email: [email protected] Mobile: 0403 165 270

SP

OO

N D

RA

IN

16,220TBC

14,40

4

5,500

8,904

36m FIRE HOSE REEL LOCATED4m FROM EXIT DOOR

54.9m TOTAL LENGTH FROMFIRE PUMP AND TANK

36m FIRE HOSE REEL LOCATED4m FROM EXIT DOOR

34.4m TOTAL LENGTHFROM FIRE HOSE REEL

62.5m TOTAL LENGTH FROMFIRE PUMP AND TANK

32.3m TOTAL LENGTHFROM FIRE HOSE REEL

66.2m TOTAL LENGTH FROMFIRE PUMP AND TANK

66.5m TOTAL LENGTH FROMFIRE PUMP AND TANK

36.4m TOTAL LENGTHFROM FIRE HOSE REEL

2500mm x 4500mm REFUSE BIN AREA TBC

WAREHOUSE CANOPY OVER

BOLLARDS

BOLLARDS

DOME POWERPOLE

POWERPOLE

WV WATER

VALVE

GASVALVE

PIPE

WATER TANKPUMP SHED WATER TANK

TELSTRA PIT

WATERMETER

WV

WV WV

VALVE

FIREHYDRANTBOOSTER

TWIN HEADFIRE HYDRANT

SEPTICPUMP

EXISTING WAREHOUSE

PROPOSED WAREHOUSEFFL: 19.19

A: 1,141.29m2

PROPOSEDLOADING DOCK

A: 160.74m2

EXISTING OFFICE

CA

SIN

O

STR

EE

T

TAP

TAP

FE

FE

EXISTING CANOPY

EXISTING CANOPY

BOL

BOL

BOLBOL

BOL

BOL

BOL

BOL

BOL

DP

DP

DP

DP

DP

DP

DP

BOLDP

NORTH

S UMM

E RS

UN

SU

N

W ITN

E RH

OT

DRYWINDS

PREVAILING

WIND

&R

AIN

DFES Plan1:250

ALL CONTRACTORS WORKING ON THIS PROJECT TO CHECK ALL DIMENSIONSAND NOTES PRIOR TO INITIATING ANY WORKS. ALL DISCREPANCIES TO BENOTIFIED TO THE PROJECT MANAGER STRAIGHT AWAY.

NOTES:- THIS DRAWING MUST BE READ IN CONJUNCTION WITH ALL RELEVANT SPECIFICATIONS, REPORTS, CONTRACTS AND DRAWINGS.- ALL BUILDING WORK TO BE CARRIED OUT IN ACCORDANCE WITH THE REQUIRED AUSTRALIA STANDARDS AND THE NCC.- ALL DIMENSIONS TAKEN TO STRUCTURAL SURFACES UNLESS OTHERWISE NOTED (STUD FRAMING / CONCRETE PANELS ETC). NOALLOWANCE FOR INTERNAL AND EXTERNAL SHEETING. ANY DISCREPANCY CONFIRM WITH OWNER OR BUILDER.- CARE SHOULD BE TAKEN TO INCLUDE AN ALLOWANCE IN CALCULATION OF CLEARANCE REQUIRED FOR FIXINGS ETC.

ABREVIATIONS:- FE = FIRE EXTINGUISHER.- FHR = FIRE HOSE REEL.- COL = COLUMN.- DP = DOWNPIPE.- PJ = PANEL JOINT.