6
ISEBE LEMFUNDO LEMPUMA KOLONI EASTERN CAPE EDUCATION DEPARTMENT OOS-KAAP ONDERWYSDEPARTEMENT NATIONAL SENIOR CERTIFICATE GRADE 12 ENGINEERING GRAPHICS AND DESIGN P1 SEPTEMBER 2017 PREPARATORY EXAMINATION MARKS: 200 TIME: 3 hours This question paper consists of 6 pages. Copyright reserved INSTRUCTIONS AND INFORMATION 1. The question paper consists of FOUR questions. 2. Answer ALL the questions. 3. All drawings must be drawn to scale 1 : 1, unless otherwise stated. 4. The questions must be answered on the answer sheets provided. 5. All the answers sheets must be re-stapled in numerical sequence and handed in irrespective of whether the question was attempted or not. 6. Careful time management is essential in order to complete all the questions. 7. Print your name in the block provided on every ANSWER SHEET. 8. All answers must be drawn accurately and neatly. 9. Any details or dimensions not given must be estimated in good proportion. 10. ALL drawings are in first angle orthographic projection, unless stated otherwise. FINAL CONVERTED MARK CHECKED BY 100 COMPLETE THE FOLLOWING: NAME NAME EXAMINATION CENTRE EXAMINATION CENTRE Please turn over 1 FOR OFFICIAL USE ONLY QUESTION MARK OBTAINED 1 2 SIGN MODERATED MARK 1 2 1 2 3 4 TOTAL 2 0 0 2 0 0 STAPLE *GRDSE*

ISEBE LEMFUNDO LEMPUMA KOLONI EASTERN CAPE …...200 x 20 mm fascia board roof components w n x 40 w electrical symbols rainwater items 150 20° rwdp Ø100 features d1 door d2sliding

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

  • ISEBE LEMFUNDO LEMPUMA KOLONI

    EASTERN CAPE EDUCATION DEPARTMENT

    OOS-KAAP ONDERWYSDEPARTEMENT

    NATIONAL

    SENIOR CERTIFICATE

    GRADE 12

    ENGINEERING GRAPHICS AND DESIGN P1

    SEPTEMBER 2017

    PREPARATORY EXAMINATION

    MARKS: 200

    TIME: 3 hours

    This question paper consists of 6 pages.

    Copyright reserved

    INSTRUCTIONS AND INFORMATION

    1. The question paper consists of FOUR questions.

    2. Answer ALL the questions.

    3. All drawings must be drawn to scale 1 : 1, unless otherwise stated.

    4. The questions must be answered on the answer sheets provided.

    5. All the answers sheets must be re-stapled in numerical sequence and

    handed in irrespective of whether the question was attempted or not.

    6. Careful time management is essential in order to complete all the questions.

    7. Print your name in the block provided on every ANSWER SHEET.

    8. All answers must be drawn accurately and neatly.

    9. Any details or dimensions not given must be estimated in good proportion.

    10. ALL drawings are in first angle orthographic projection, unless stated

    otherwise.

    FINAL CONVERTED

    MARK

    CHECKED BY

    100

    COMPLETE THE FOLLOWING:

    NAME

    NAME

    EXAMINATION CENTRE

    EXAMINATION CENTRE

    Please turn over 1

    FOR OFFICIAL USE ONLY

    QUESTION MARK OBTAINED

    1

    2

    SIGN

    MODERATED

    MARK

    1

    2

    1

    2

    3

    4

    TOTAL

    2 0 0 2 0 0

    S

    T

    A

    P

    L

    E

    *GRDSE*

  • CLIENT'S SIGNATURE ...................................

    ARCHITECT'S SIGNATURE ...........................

    PROPOSED NEW OUTBUILDING FOR

    MRS A. BAYETE ON STAND 567, 1

    MAHASHI STREET, MTHATHA.

    Engineering graphichs and design / P1

    QUESTIONS ANSWERS

    1

    What is the reference code of the drawing?

    1

    2

    Who checked the drawing?

    1

    3

    On what date was the site plan printed?

    1

    4

    What revision must be done to the site plan?

    1

    5

    Who must sign the drawing?

    2

    6

    What feature is partially visible on the stand to the south east

    of stand 567?

    2

    7

    What is the length of boundary line DE in meters?

    1

    8 What does the abbreviation IE stand for? 1

    9 What does the abbreviation W stand for? 1

    10

    How many rodding eyes are indicated on the drawing?

    1

    11

    What feature is indicated by arrow A?

    1

    12

    What feature is indicated by arrow B?

    1

    13

    What colour is used on the siteplan for all proposed work?

    1

    14 What colour is used in elevations for new wood? 1

    15

    Calculate the difference in height of corner B and D in meter.

    2

    16

    In the space provided below, determine the perimeter of stand 567 in meters.

    2

    17

    In the space provided below, determine the total area of the proposed outbuiding in square meters.

    3

    18

    In the space provided in the title panel, draw, in neat freehand, the top view of the SABS 10143

    convention for FACE BRICK.

    2

    19

    In the space provided in the title panel, draw, in neat freehand, the front view and top view of the

    SABS 10143 convention for a DOUBLE SINK UNIT.

    4

    TOTAL29

    Copyright reserved Please turn over

    2

    S

    T

    A

    P

    L

    E

    QUESTION 1: ANALYTICAL (CIVIL)

    Given:

    The site plan for an existing house with a proposed new outbuilding, a title panel and a table of questions. The

    drawing has not been prepared to the indicated scale.

    Instructions:

    Complete the table below by neatly answering the questions, which refer to the accompanying drawing and title

    panel. [29]

    CLIENT'S SIGNATURE ...................................

    NOTE:

    Contractors must verify all dimensions and

    levels on site before commencing work.

    Architects to be notified immediately of any

    discrepancies.

    ANSWER 18

    In the space provided below, draw, in

    neat freehand, hatching for SANS

    10143 convention for FACE BRICK.

    ARCHITECT'S SIGNATURE ...........................

    REVISION DATE

    PRINTED BY

    DRAWING TITLE

    DATE OF PRINT

    PROJECT

    DESCRIPTION

    PROJECT NUMBER

    REFERENCE CODE

    DRAWN CHECKED

    DRAWING NUMBER

    SCALEDATE

    PROPOSED NEW OUTBUILDING FOR

    MRS A. BAYETE ON STAND 567, 1

    MAHASHI STREET, MTHATHA.

    QU1-2017

    1 : 3002017-08-10

    LAND SURVEYOR'S CERTIFICATE OF THE

    SIDE LENGTHS AND CORNER HEIGHTS

    ON STAND 132.

    SURVEYED ON 2017-08-05

    LENGTHS IN

    MILLIMETERS

    CORNER HEIGHTS

    IN METERS

    AB = 23500 A = 711,4

    BC = 20000 B = 710,5

    CD = 26000 C = 710,25

    DE = 17500 D = 711,1

    EA = 3535 E = 711,8

    ANSWER 16

    Show ALL calculations.

    ANSWER 17

    Show ALL calculations.

    ECDBE1-2017 10810

    SITE PLAN

    PRINT ALL CC 2017-08-15

    FREDDIE KRUGER

    2017-08-12A

    USE CORRECT

    COLOUR FOR NEW

    BUILDING

    ANSWER 19

    In the space provided below, draw, in

    neat freehand, the front view and top

    view of the SANS 10143 convention

    for a DOUBLE SINK UNIT.

    Engineering graphichs and design / P1 NCS EC DBE/September 2017

    NAME

    NAME

    ST

    AN

    D 5

    66

    ST

    AN

    D 5

    67

    STAND 568

    MA

    HA

    SH

    I S

    TR

    EE

    T

    TEMBU STREET

    20

    00

    B

    L

    15

    00

    B

    L

    2000 BL

    1500 BL

    A

    BC

    D

    E

    W

    45

    00

    8500

    4

    0

    0

    0

    3

    5

    0

    0

    6

    5

    0

    0

    2

    0

    0

    0

    5

    0

    0

    0

    7

    5

    0

    0

    3

    0

    0

    0

    2

    0

    0

    0

    RE

    IE

    IE

    IE

    RE

    IE

    RE

    IE

    MH

    MH

    MH

    A

    B

    PROPOSED

    NEW OUT

    BUILDING

    7

    1

    1

    7

    1

    2

    1500

    25

    00

    IC

    1

    2

    0

    0

    0

    E

    X

    I

    S

    T

    I

    N

    G

    H

    O

    U

    S

    E

  • ASSESSMENT CRITERIA

    1

    HEXAGON

    CONSTRUCTION +

    TOP VIEW

    7

    2 FRONT VIEW 3

    3 TRUE LENGHTS 6

    4 DEVELOPMENT 17

    PENALTIES (-)

    TOTAL 33

    Copyright reserved Please turn over

    3

    S

    T

    A

    P

    L

    E

    Engineering graphichs and design / P1 NCS EC DBE/September 2017

    NAME

    NAME

    QUESTION 2: TRANSITION PIECE

    Given:

    The front view, right view and the top view of a rectangular

    to hexagon transition piece.

    The starting point S for the top view of the hexagon and the

    ground line XY. The right angle labeled R as the start for

    the development.

    Instructions:

    Draw, to scale 1 : 1, the following views of the transition

    piece:

    2.1 The top view

    2.2 The front view

    2.3 Develop the surface of the transition piece and make

    AB the seam.

    Show ALL fold lines.

    Show ALL constructions.

    AB is the seam of the transition piece. [33]

    X

    R

    X Y

    a

    b

    a1b1

    a2

    b2

    S

    S

    Y

    55

    48

    66

    20

  • ASSESSMENT CRITERIA

    1

    CONSTRUCTION +

    VPs

    7

    2 ROOF 8

    3 WALLS 13

    1

    2

    4 SEMI-CIRCLE 5

    1

    2

    5 WINDOWS 6

    TOTAL 40

    Copyright reserved Please turn over

    4

    S

    T

    A

    P

    L

    E

    QUESTION 3: PERSPECTIVE

    Given:

    Two views of a house and the information

    needed to draw a two-point perspective

    drawing

    PP − Picture plane

    HL − Horizon line

    GL − Ground line

    SP − Station point

    Instructions:

    Complete the perspective drawing.

    · Align the drawing sheet with the ground line(GL).

    · Determine and label the vanishing points.· Show ALL necessary construction.· Show the wall thickness at the openings.· NO hidden detail is required. [40]

    Engineering graphichs and design / P1 NCS DoE EC/September 2017

    NAME

    NAME

    SP

    PP

    HL

    GL

    HL

  • 300

    A B

    A

    A B A

    2

    0

    °

    41

    65

    25

    75

    3500

    2

    25

    5

    7

    4

    4

    4

    4

    3

    1

    1

    1

    5

    6

    6

    D1

    D1

    D1

    D1

    D2

    W2 W3

    W1

    W3

    1

    2

    4

    3

    WB

    SH

    WC

    S

    25

    0

    25

    0

    20

    0

    10

    0

    24

    60

    20

    0

    50

    0

    10

    0

    100

    1

    200

    500

    Copyright reserved Please turn over

    5

    S

    T

    A

    P

    L

    E

    INCOMPLETE SOUTH WEST ELEVATION

    75 x 50 mm PURLINS

    200 x 20 mm FASCIA BOARD

    ROOF COMPONENTS

    n x 40 W

    W

    ELECTRICAL SYMBOLS

    RAINWATER

    ITEMS

    150

    20°

    RWDP

    Ø100

    FEATURES

    D1 DOOR

    D2 SLIDING DOOR

    W1 WINDOW

    W2 WINDOW

    W3 WINDOW

    FIXTURES

    WC TOILET

    WB WASH BASIN

    SH SHOWER

    S SINK

    ELECTRICAL FITTINGS

    1. LIGHT SWITCH - SINGLE-POLE

    2. LIGHT SWITCH - DOUBLE-POLE

    3. FLUORESCENT LIGHT 2 x 40 W

    4. CEILING LIGHT

    5. WALL MOUNTED LIGHT

    6. SWITCHED SOCKET OUTLET

    7. DISTRIBUTION BOARD

    NOTE:

    THE ARROWS ON THE FLOOR

    PLAN SHOWS THE LIGHT

    CONNECTION TO THE SWITCH.

    INCOMPLETE FLOOR PLAN

    Instructions:

    Answer this question on page 6.

    4.1 Using the given incomplete floor plan, draw, in first-angle

    orthographic projection and to scale 1 : 50, the following

    views of the house:

    4.1.1 THE COMPLETE FLOOR PLAN

    Add the following features to the drawing:

    · ALL doors and windows· ALL fixtures as indicated by abbreviations· ALL electrical fittings as indicated by numbers· ALL hatching detail4.1.2 THE SOUTH WEST ELEVATION

    Show the following features on the drawing:

    · The outside walls, windows and door detail· The roof detail, including the fascia board, gutter, rain-

    water down pipe, barge board and roofcap

    · The finished floor level

    4.2 Using the incomplete foundation and break line on page 6,

    draw, to scale 1 : 20, a DETAILED SECTION according to

    cutting plane A-A of the area in the ellipse shown on the

    incomplete floor plan.

    · Show the following features on the drawing:· The complete foundation, external wall with window and

    internal wall with door detail

    · The roof detail, including the fascia board and gutter· ALL features to the left of the section· ALL hatching detail. ONLY the substructure hatching

    may be drawn in neat freehand

    · Start at the given starting point

    Label the following:

    · The south west elevation including the scale· The room designations and floor finishes· Using the correct abbreviations, label the following features in

    the correct view: ground level; finished floor level and damp

    proof course

    NOTE:

    ALL drawings must comply with the guidelines and graphical

    symbols contained in the SANS 10143. [98]

    ROOM DESIGNATIONS

    WINDOW (W2)

    600

    60

    0

    GROUND

    LEVEL

    INCOMPLETE FOUNDATION

    AND EXTERNAL WALL DETAIL

    25 mm

    SCREED

    WINDOW (W1)

    80

    0

    1000

    ROOF NOTES:

    ROOF PITCH 20°

    200 x 20 mm FACIA BOARD ON SIDES

    ROOF OVERHANG 500 mm TO TRUSS END

    300 x 75 mm FIBRE CEMENT BARGE BOARDS ON ROOF ENDS

    ROOF COVER 50 mm IBR SHEET ON

    75 x 50 mm PURLINS @ 940 mm c/c

    114 x 38 mm ROOF TRUSS ON 114 x 38 mm WALL PLATES

    9 mm CEILING BOARD ON

    38 x 38 mm BRANDERING STRIPS @ 450 mm c/c

    100 x 150 mm GUTTER ON SIDES

    40

    0

    60

    0

    TOILET

    (WC)

    400

    SANITARY FIXTURES

    75

    0

    20

    0

    WASH BASIN

    (WB)

    FLOOR LEVEL

    35

    0

    500

    20

    0

    85

    0

    WINDOW (W3)

    40

    0

    SHOWER (SH)

    50

    0

    400

    1200

    SINK (S)

    1500

    10

    00

    85

    0

    850

    20

    50

    TO FIT50

    FLOOR FINISHES

    1 BEDROOM: CARPET

    2 BATHROOM: TILE

    3 OPEN PLAN AREA: TILE

    4 PATIO: TILE

    DOOR FRAME AND

    DOOR (D1)

    DOOR AND WINDOW SCHEDULE

    10

    0

    10

    0

    NOTE: 200 x 100 mm BRICK ON EDGE

    SILL UNDER ALL WINDOWS

    10

    0

    QUESTION 4: CIVIL DRAWING

    Given:

    · The incomplete south west elevation of a house, showing thewalls, the windows schematic diagram, the door opening, the

    roof and notes

    · The incomplete floor plan showing the walls, position of thedoors, windows, fixtures and the electrical layout

    · Roof notes with a schematic diagram of the roof truss insection

    · The incomplete foundation and detail of the external andinternal walls

    · Room designations and floor finishes· A door and window schedule· A table of sanitary fixtures· A table of roof components· A table of electrical symbols· A table of rainwater items· The floor plan of the house, drawn to scale 1 : 50 on page 6

    100 x 200 mm

    LINTEL

    ABOVE DOOR

    AND WINDOW

    OPENINGS

    ROOF CAP

    100 x 150 mm GUTTER

    200 x 20 mm FACIA BOARD

    SLIDING DOOR OPENING

    WINDOW OPENING

    RWDP

    FINISHED FLOOR LEVEL

    GROUND LINE

    Engineering graphichs and design / P1 NCS EC DBE/September 2017

    300 x 75 mm FIBRE CEMENT

    BARGE BOARD

    25 mm

    SCREED

    INCOMPLETE NON LOAD

    BEARING WALL AND

    FOUNDATION DETAILS

    85

    0

    400

    400

    EQUAL

    9

    4

    0

    c

    /

    c

    9

    4

    0

    c

    /

    c

    9

    4

    0

    c

    /

    c

    9

    4

    0

    c

    /

    c

    EQUAL EQUAL EQUAL

    STEP 2000 x 300 x 150

    SCHEMATIC DIAGRAM OF ROOFTRUSS

    20

    50

    1700

    DOOR FRAME AND DOOR (D2)

    OPENING FIXED

    PANEL

    GL

    520

    300 x 75 mm FIBRE CEMENT

    BARGE BOARD

    WINDOW NOTES

    A = OPENING SIDE

    B = FIXED PANE

    FRAMES 40 mm

    10

    0

  • ASSESSMENT CRITERIA

    FLOOR PLAN

    1

    DOORS +

    WINDOWS

    14

    1

    2

    2

    ELECTRICAL

    12

    1

    2

    3FIXTURES

    6

    4

    HATCHING

    5

    5LABELS

    5

    SUBTOTAL 43

    SOUTH WEST ELEVATION

    1

    ROOF

    3

    1

    2

    2

    WALLS + RWDP +

    FFL + GULLEY +

    STEP

    6

    3DOOR + WINDOW

    7

    1

    2

    4

    LABELS

    1

    SUBTOTAL 18

    DETAILED SECTION

    1

    ROOF

    12

    2

    FOUNDATIONS +

    WALLS + SLAB

    8

    3

    DOOR + SILL +

    WINDOWS +

    LINTELS

    5

    4

    WC + SHOWER

    3

    5HATCHING

    7

    6LABELS

    2

    SUBTOTAL 37

    TOTAL 98

    PENALTIES (-)

    FINAL TOTAL

    PENALTIES

    1INCORRECT OVERALL SCALE

    2INCORRECT POSITIONING OF VIEWS

    3NON-ALIGNMENT OF VIEWS

    TOTAL PENALTIES (-)

    Copyright reserved

    6

    S

    T

    A

    P

    L

    E

    Engineering graphichs and design / P1 NCS EC DBE/September 2017

    NAME

    NAME

    SECTION A-A

    SCALE 1 : 20

    STARTING POINT FOR

    DETAILED SECTION

    FLOOR PLAN

    SCALE 1 : 50

    AA

    RWDP

    RWDP

    Sheets and ViewsPAGE 1PAGE 2PAGE 3PAGE 4PAGE 5PAGE 6