5
MUHAMMAD IRFAN MUHAMMAD IRFAN (ELECTRICAL TECHNICIAN) Contact Number: +92-333-6751851 +92-300-6751851 E-mail: [email protected] Skype id: iffi153 Mailing Address: House No. A-88, Phase- 2, Ghulshan-e-Heeded, Karachi. OBJECTIVE OBJECTIVE Looking for rewarding and challenging career aim in field of Electrical Maintenance that can use my knowledge, skill and ability to make valuable contribution for company. EXPERIENCE SUMMARY: ( Total 06 year) INCLUDEPICTURE "ooxWord://word/media/image3.emf" \* MERGEFORMATINET I am DAE in Electrical Technology having 03 years working experienced (Including Apprenticeship) as Electrical Technician in Fauji Fertilizer B in qasim limited (FFBL). During my professional career I have experience of performing all types of Maintenance, Repair, Modification, Installation, Overhauling of plant Electrical Equipments like motors LV/MV, Motor Control Centers, VFD`s Transformers LV/MV, Switchgears LV/MV like Air circuit breaker, Vaccume circuit breaker and SF6 type circuit breakers, UPS and batteries back up, Lighting system, PA system, Fire alarm system, Protection Relays, Rack in/out of both LV and MV Starters and Switchgears according to IMS procedures and Plant Safety rules and regulation. Having 03 years working experienced as Electrical Technician in FFBL POWER COMPANY LIMITED (FPCL) 118MW coal power plant. During this job I have experience of Erection & commissioning of Coal power plant, Cable termination of power and control of LV &MV on Switch gear and motor end. Inspection and

irfan new CV

Embed Size (px)

Citation preview

Page 1: irfan new CV

MUHAMMAD IRFAN MUHAMMAD IRFAN (ELECTRICAL TECHNICIAN)

Contact Number: +92-333-6751851+92-300-6751851

E-mail: [email protected] id: iffi153Mailing Address: House No. A-88, Phase-2,

Ghulshan-e-Heeded, Karachi.

OBJECTIVEOBJECTIVE Looking for rewarding and challenging career aim in field of Electrical Maintenance that can use my knowledge, skill and ability to make valuable contribution for company. EXPERIENCE SUMMARY: ( Total 06 year)

INCLUDEPICTURE "ooxWord://word/media/image3.emf" \* MERGEFORMATINET I am DAE in Electrical Technology having 03 years working experienced (Including Apprenticeship) as Electrical Technician in Fauji Fertilizer Bin qasim limited (FFBL). During my professional career I have experience of performing all types of Maintenance, Repair, Modification, Installation, Overhauling of plant Electrical Equipments like motors LV/MV, Motor Control Centers, VFD`s Transformers LV/MV, Switchgears LV/MV like Air circuit breaker, Vaccume circuit breaker and SF6 type circuit breakers, UPS and batteries back up, Lighting system, PA system, Fire alarm system, Protection Relays, Rack in/out of both LV and MV Starters and Switchgears according to IMS procedures and Plant Safety rules and regulation.

Having 03 years working experienced as Electrical Technician in FFBL POWER COMPANY LIMITED (FPCL) 118MW coal power plant. During this job I have experience of Erection & commissioning of Coal power plant, Cable termination of power and control of LV &MV on Switch gear and motor end. Inspection and pre commissioning checks of switch gear and motor control center, LV & MV Transformers, LV & MV Motors.

RESPONSIBILTIES:

Currently I am working in independent rotating shifts as shift electrical technician my responsibilities include

Rack in/out as per IMS procedure Fault diagnosis, scheduled inspection and monitoring of plant electrical equipments Planned preventive maintenance of electrical equipments Fault rectification of plant electrical equipment Support services provision during

shutdown/start up and normal plant operation Familiar to work in hazardous locations and maintenance on classified equipments

Page 2: irfan new CV

SAFETY CONSCIOUSNESS (HSE):Handsome awareness against work permits procedures, area classification and hazardous equipment and personal and plant safety. Having fire-fighting training, special training on safety topics likes Housekeeping, Fire Fighting, and Use of personal protective equipment, Confined spaces, Emergency handling.

PROFESSIONAL SKILLGENERATORS (CATER PILLAR & GE)

Knowledge about Diesel Engine Generator & Steam Turbine Generator of following Rating

2*26 MW GAS Turbine Generator (13.8KV) 2 MW EDG GENERATORS (13.8KV) 2*24 MW Steam Turbine Generator (13.8 KV) Knowledge about Protection & Excitation system Synchronization procedure of

Generators. Preventive or corrective maintenance.

LV MOTORS (GE, VEM, Louis Allis, Louis Charles, Siemens, ABB, Hyundai) Preventive Maintenance, Condition Monitoring ,Cable Termination & Connection,

Troubleshooting and Greasing According to Greasing Schedule and Abnormal Sound of motor. 1kw TO 850kw. 480v/60 Hz & 380v/50 Hz. QPM & YPM

MV MOTORS (Weg, Siemens,Hyundai) Preventive Maintenance Of Motor. 1.5MW to 2MW on 6.6KV. Maintenance & overhauling of MV Motors Overhauling & Meggering, Preventive maintenance, RTD Checking (PT-100, Copper-10)

TRANSFORMERS (ABB, AEG, Cutler -Hammer)

Preventive Maintenance, Corrective Maintenance, Oil Testing, Silica Gel Replacement, Field Servicing of Transformers(Up to 800KVA TO 30/40MVA).

LV/MV Transformers rated up to 12 MVA. Conservator and Hermetically sealed type, dry type

Oil sampling and testing, Testing of protections (Buchholz Relay, Tap changer, PRD, Temperature & Level Gauge)

VSD,s & SOFT STARTERS(AB,CEG ELEC,SIEMENS,DANFOSS) Knowledge & Maintenance of Motors Controlled by Soft Starters & V.S.D,s

Page 2 of 4

Page 3: irfan new CV

SWITCH-GEARS (AEG, ABB, Siemens, Cutler-Hammer) HV = 13.8 KV, MV = 2.4 KV, LV = 480, 380 Volt Preventive Maintenance, Corrective Maintenance and Servicing of L.T. Switchgears. Troubleshooting of Different Interlocking Circuits (Auto Cut In / Cut Out) on Level,

Pressure and Vibration. Performed switching operations of HV switchgear during normal & emergency mode at

the voltage rating of 0.4, 2.4, 6.6, 13.8KV.

UPS & DC CHARGER (CEGELEC) Knowledge about UPS System of 100 KVA Unit.

PROTECTION SYSTEM (ABB,AREVA,Westinghouse, AEG, SIEMENS,GE)

PROTECTION RELAYS FOR GENERATOR, MEDIUM VOLTAGE BUS BARS, MOTOR PROTECTION, TRANSFORMER PROTECTION AND LOW VOLTAGE SYSTEM. MADE BY (SIEMENS, ABB, GE).

Electromagnetic and Electrostatic Multifunctional Microprocessor based IQ-1000II,MP- 3000,PS 451 Synchrocheck relays, under voltage relays, Instantaneous Over current relays,

Directional Power relays, Transformer Thermal relay, over voltage relay, Liquid or Gas pressure or vacuum relays, Notching or Jogging device, Under Frequency and Over Frequency relays, Locking-Out relays, Differential protection relays, and Earth Fault relay

BATTERIES:

Different kind of battery bank used for DC Charger and UPS. Weekly preventive maintenance of battery banks both dry and electrolyte filled, Capacity test. water level make up, reading of voltage per cell, reading of voltage whole bank, specific gravity per cell, temperature of battery room.

ERECTION & MODIFICATION EXPERIENCE

Installation of LV & MV motors up to 1MW/2.4KV.Cable termination of power and control of LV &MV on Switchgear and motor end.

Inspection and pre commissioning checks of switchgear and motor control centre. Supervision of cable laying and cable pulling of Power & control from cable trays.

Ducts/trenches.

FAMILIAR WITH USE OF:

Oil Dielectric Strength Tester Multiamps Relay Tester

Page 3 of 4

Page 4: irfan new CV

SPECIAL TRAINING COURSES:

Electrical Area Classification. Use of Personal Protective Equipments. Permit to Work Procedure.(PTW) Fire Fighting Training. Plant Safety.

EXPECTATION Hopping for the BEST from the BEST organization on my BEST record undergoing

through the BEST merit policy.

PERSONAL PROFILEFather Name: Farzand AliDate of Birth: 15-03-1991.C.N.I.C. No.: 31303-5715452-1Religion: IslamNationality: Pakistani.Marital Status: MarriedPermanent Address: House No. 04 Street no 01Colony Ghous Pur By

Pass Road Rahim Yar Khan.

Page 4 of 4