What’s New?

• LM2500 PLUS gas turbine

– Up to 30% more power!

• Two-trailer design

– 75% reduction in footprint

• Improved interconnection design

– Faster installation and set-up

Page 3: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

10 /

31% More Power at 60 Hz !

20

22

24

26

28

30

32

34

36

38

0 20 40 60 80 100

LM2500 (60 Hz)

LM2500+ (60 Hz)

170ER (F 60 Hz)

MW

Ambient Temperature – deg. F

31%

(Generator Limit)

Page 4: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

11 /

13% More Power at 50 Hz !

20

22

24

26

28

30

32

34

0 20 40 60 80 100

LM2500 (50 Hz)

LM2500+ (50 Hz)

170ER (F 50 Hz)

50 Hz Performance

MW

Ambient Temperature – deg. F

13%

(Generator Limit)

Page 5: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

12 /

What’s New?

• LM2500 PLUS gas turbine

– Up to 31% more power!

• Two-trailer design

– Smaller footprint

• Improved interconnection design

– Faster installation and set-up

Page 6: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

13 /

New Two-Trailer Design

Top-Mounted Inlet & Exhaust Assemblies

LM2500+ Gas Turbine

Page 7: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

14 /

TM2500+ General Arrangement

Transportation Jeep

Trailer Gooseneck

Transportation Stinger

Inlet Filter Assembly

Exhaust Stack

GE LM2500+ Gas Turbine

Brush BDAX 62-170ER Generator

Generator Inlet &

Exhaust

Inlet Plenum

Switchgear

Main

Trailer

Hydraulic Starter

Lube Oil Coolers

Fuel/Water Pumps

Turbine Enclosure Fire Suppression

Control Room & Battery

Room

Auxiliary Trailer

Page 8: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

15 /

TM2500/+ Footprint

107’ x 67’

78’ x 21’

77% Reduction in Installed Footprint

Page 9: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

16 /

What’s New?

• LM2500 PLUS gas turbine

– Up to 31% more power!

• Two-trailer design

– Smaller footprint

• Improved interconnection design

– Faster installation and set-up

Page 10: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

17 /

Interconnection Improvements for Faster Set-up

• Improved inlet & exhaust connectionsfor quicker installation& set-up

• Can be set upin 24 hours

Turbine EnclosureAssembly

Inlet Filter Assembly

Exhaust DuctAssembly

Inlet Plenum

Page 11: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

18 /

Back-up

Page 12: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

19 /

Site Preparation / Foundation•Level within 6 inches per 100 feet

•Solid crushed gravel with 1” steel plates

•Adequate access / space, well-lit, secure

Page 13: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

20 /

Fuel / Water Connections

Natural Gas Supply (3” pipe)

NOx Water Supply(2” pipe)

Liquid Fuel Supply (2” pipe)

Auxiliary Trailer (top view)

Auxiliary Trailer (side view)

Page 14: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

21 /

Electrical Connections

• Generator output 13.8 kV @ 60 Hz (11.5 kV @ 50 Hz.)

• Auxiliary power requirement 480V, 60 Hz, to motor control center main circuit breaker (250 kW) High Voltage

Termination

Page 15: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

22 /

Grounding

• Customer furnished grounding system

• GE provides ground grid specification and interconnection requirements

4’ trailer to ground

5’ trailer to trailer8’ trailer to ground 6’ trailer to

ground

5’ trailer to trailer

15’ trailer to trailer

35’ trailer to ground

26’ trailer to trailer

Grounding Block

1/4 in thread bolt, 3/8 in deep

Page 16: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

23 /

Customer Interface Details (TM2500)Fuel• Gas supply pressure is 395 (+/- 20) PSIG at a rate of 12,000 pph (250 mmbtu/hr or 6mscf/day)

• Liquid Fuel (diesel) supply pressure is 30 (+/- 10) PSIG, up to 40 GPM (max.)

Water (for NOx suppression)• Minimum supply pressure is 15 PSIG up to 28 GPM (max.)

Inlet/Exhaust Air• Nominal inlet air flow 150,000 CFM (120,000 turbine / 30,000 enclosure ventilation)

• Exhaust stack height is 20’ when fully assembled

– Flange dimensions 96” x 96”)

– Exhaust gas flow 490,000-550,000 lbs/hr @ 980°F

Emissions

• Liquid Fuel: 42 ppm NOx with water injection

• Gas Fuel: 25 ppm NOx with water injection

Noise

• Approximately 88 dBa

Waste

• Lubricating oils (turbine & generator)

• Turbine wash detergent and rinse water

Page 17: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

24 /

Snorkel Lift (Telescopic Boom) (Lull) 6,000 lb. Variable Reach Forklift

25-45 Ton Crane

TM2500 Unit Installation Equipment

Front Loader w/forks to move sea containers

Page 18: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

SCOPE OF SUPPLY

TM 2500+ MOBILE TURBINE GENERATOR

Gas Turbine

Generator

Unit Enclosure

Main Trailer and Jeep

Auxiliary Trailer

Gas Turbine Baseplate

Turbine Exhaust Stack

Inlet Filter Assembly

Fuel System

Dematerialized Water Injection System

Fuel Water Pumps

Lube Oil Systems

Switchgear

Auxiliary Trailer

Electro-Hydraulic Starting Module

“Off Line” Soak Wash System

Fire Protection System

Fin Fan Cooler

Turbine Ventilation Silencer

Digital Control System

Generator Protective Relays

Unit Motor Control Center

Battery and Charger System

Proprietary and Confidential

Page 19: Introducing the TM2500+ - TradeKeyimgusr.tradekey.com/images/uploadedimages/brochures/1/1/1244147... · GE LM2500+ Gas Turbine Brush BDAX 62-170ER Generator Generator Inlet & Exhaust

Optional Equipment not included in the package

Absorption chiller and chilled water supply system

Balance of plant and energy optimization controls

Boiler feed pump and auto level control assembly

Building, foundations, anchor bolts, embedment and grouting

Bus bars and bus duct beyond generator line

Cooling tower and circulating water system

Deaeration and chemical injection equipment

Desuperheater equipment

Distributed plant control

Filter house support structure, other than standard

Field Supervision

Fuel, fluids and chemicals

Fuel storage tanks, forwarding equipment and primary fuel filter

Gas compression, filtration and separation or regulation equipment

Heat recovery boiler and blow down controls

High voltage transformer(s), cables, switchgear and associated equipment

Interconnecting piping, conduit, and wiring between equipment modules (site layout is unknown at this time)

Plant utilities

Power plant calibration tools and ordinary hand tools

Spare parts (quoted separately)

Steam filtration and purification equipment

Steam turbine condenser and condensate pumping equipment

Transportation to job site and off loading of equipment

Water injection pressurization equipment

Water treatment and purification equipment

Yard light and fences