1 Introduction
DEVIreg™ 534 is an electronic timer temperature controller,specially designed for floor heating systems. The thermo-stat is provided with a combination of a floor sensor and aroom sensor to measure and control the desired floor androom temperature. It can be either flush-mounted or sur-face-mounted.
Once set, the thermostat will automatically adjust the heatto meet your comfort requirements by measuring the floortemperature and combining it with the measured air tem-perature regardless of changing weather conditions.
DEVIreg™ 534
Installation Guide 3
The thermostat has buttons for adjusting the temperaturesetting, and a LED indicator showing standby periods(green light) and heating periods (red light).
More information on this product can also be found at:devireg.devi.com
1.1 Technical Specifications
Operation voltage 220-240V~, 50Hz
Standby power consump-tion
Max 0.30W
Relay:Resistive loadInductive load
Max 15A / 3450W @ 230Vcos φ= 0.3 max 1A
Sensing units NTC 15kOhm at 25°C
Sensing values:0°C25°C50°C
42kOhm15kOhm6kOhm
Hysteresis ± 0.4°C with floor sensoronly
Ambient temperature -10°C to +30°C
Frost protection tempera-ture
5°C -
DEVIreg™ 534
4 Installation Guide
Temperature range 15-32°C with floor sensoronly
Cable specification max 1x4mm2 or 2x2,5mm2
Ball pressure temperature 75°C
Pollution degree 2 (domestic use)
Type 1C
Storage temperature -20°C to +65°C
IP class 31
Protection class Class II -
Dimensions 85 x 85 x 54mm (in-walldepth: 24mm)
Weight 107g
The product complies with the EN/IEC Standard "Automaticelectrical controls for household and similar use":
▪ EN/IEC 60730-1 (general)▪ EN/IEC 60730-2-7 (timer)▪ EN/IEC 60730-2-9 (thermostat)
DEVIreg™ 534
Installation Guide 5
1.2 Safety Instructions
Make sure the mains supply to the thermostat is turned offbefore installation.
Please also note the following:
▪ The installation of the thermostat must be done by anauthorized and qualified installer according to localregulations.
▪ The thermostat must be connected to a power supplyvia an all-pole disconnection switch.
▪ The sensor is to be considered as live voltage. Havethis in mind if the sensor must be extended.
▪ Always connect the thermostat to continuous powersupply.
▪ Do not expose the thermostat to moisture, water, dust,and excessive heat.
2 Mounting Instructions
Please observe the following placement guidelines:
Place the thermostat at a suitable heighton the wall (typically 80-170cm.).
DEVIreg™ 534
6 Installation Guide
The thermostat should not be placed inwet rooms. Place it in an adjacent room.Always place the thermostat according toNFC15100 - part 7-701.
Do not place the thermostat in a way thatit will be exposed to direct sunlight.
Note: A floor sensor enables a more accu-rate temperature control and is recom-mended in all floor heating applicationsand mandatory under wooden floors toreduce the risk of over-heating the floor.
▪ Place the floor sensor in a conduit in an appropriateplace where it is not exposed to sunlight or draft fromdoor openings.
▪ Equally distant and >2cm from two heating cables.▪ The conduit should be flush with the floor surface -
countersink the conduit if necessary.▪ Route the conduit to the connection box.▪ The bending radius of the conduit must be min 50mm.
DEVIreg™ 534
Installation Guide 7
Follow the steps below to mount the thermostat:
1. Open the thermostat:
devireg™550 devireg™550
▪ Gently press the release tab in the bottom of thethermostat by a flat object.
▪ Carefully pull off the front cover.
2. Connect the thermostat according to the connectiondiagram.
IP31
-10T30
D534
Mains
220-240V~
Max. Load
15 (1) A Se
nso
r
N L NTCNLOAD
LLOAD
Standby maximum 0.3W
DEVIreg™ 534
8 Installation Guide
The screen of the heating cable must be connected tothe earth conductor of the power supply cable by us-ing a separate connector.
Note: Always install the floor sensor in a conduit in thefloor.
3. Mount and reassemble the thermostat.
▪ Fasten the thermostat to a socket or an exterior wallbox by driving the screws through the holes in eachside of the thermostat.
▪ Tighten the screws to fasten the thermostat.
4. Turn on the power supply.
Initially main supply the thermostat for 15 hours to fullycharge the battery. The current time and day is then keptfor 80 days if mains supply is off. All other settings are stor-ed permanently.
3 Settings
Sensor: How to specify whether an external floor sen-sor, the built-in room sensor or both is used to controlthe floor heatingNote: The floor sensor option is selected by default.
DEVIreg™ 534
Installation Guide 9
1. Press the installation button D with a blade end.
devireg™550 devireg™550
D
2. Press the • button.
3. Select one of the following options using the ▲▼buttons:
If only a floor sensor is used, choose:The built-in room sensor is not used.This option is suitable for rooms inwhich a constant floor temperature isrequired, e.g. in a bathroom.
If both a room sensor and a floor sen-sor is used, choose:This option is suitable for all roomsbut wet rooms. The thermostat mustbe installed in the same room as thefloor sensor and the heating elements.
DEVIreg™ 534
10 Installation Guide
If only a room sensor is used, choose .This option is not recommendabledue to an increased risk of overheat-ing the floor. The thermostat must beinstalled in the same room as theheating elements.
4. To accept the new selected sensor mode, press •.
5. Press installation button D to configure settings.
6. If you have chosen the floor sensor or room/floor sen-sor option, press ▲▼ (up/down) buttons to continueto the next setting.
How to set the maximum floor temperatureSpecial condition: This setting only applies if a floor sensoris used (the floor sensor or room/floor sensor option hasbeen set).Note: The maximum floor temperature is set to 28°C bydefault.
1. To change the default temperature setting - press the• button.
2. Select the new temperature by using the ▲▼ but-tons.
3. To accept the new selected temperature, press •.
DEVIreg™ 534
Installation Guide 11
4. Press installation button D to configure settings.
devireg™550 devireg™550
D
5. Press ▲▼ (up/down) buttons to continue the nextsetting.
Note: Please contact the floor supplier before changing themaximum floor temperature and be aware of the following:
▪ The floor temperature is measured where the sensor isplaced.
▪ The temperature of the bottom of a wooden floor canbe up to 10 degrees higher than the top.
▪ Floor manufactures often specify the max temperatureon the top surface of the floor (usually 27-28˚C).
▪ Always use a floor sensor or a room + floor sensorcombination to control floor heating. Without a floorsensor, the temperature control may be less accurateand you risk overheating the floor.
DEVIreg™ 534
12 Installation Guide
Thermalresist-ance[m2K/W]
Examples of floor-ing
Details Approximatesetting for25˚C floortemperature
0.05 8 mm HDF basedlaminate
> 800 kg/m3 28˚C
0.10 14 mm beech par-quet
650 - 800kg/m3
31˚C
0.13 22 mm solid oakplank
> 800 kg/m3 32˚C
< 0.17 Max. carpet thick-ness suitable forfloor heating
acc. to EN1307
34˚C
0.18 22 mm solid firplanks
450 - 650kg/m3
35°C
How to define the temperature scale
You can select the display type. The choice is either numeri-cal scale 1-6 or Celsius scale 15° to 28°. Default is Celsiusscale. When selecting Celsius, the display will show the ac-tual temperature at the floor sensor.1. To change the default temperature scale, press the •
button.
2. Select a scale, use the ▲▼ buttons.
3. To accept the selected temperature scale, press •.
DEVIreg™ 534
Installation Guide 13
4. If desired, go back or forward through your installa-tion settings by pressing the ▲▼ (up/down) buttons.
5. Press installation button D to exit the installationmode.
6. Put the frame and front back on.
4 Warranty
2Y E A R
5 Disposal Instruction
DEVIreg™ 534
14 Installation Guide
DEVIreg™ 534
Danfoss A/SElectric Heating SystemsUlvehavevej 617100 VejleDenmarkPhone: +45 7488 8500Fax: +45 7488 8501E-mail: [email protected]
Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter itsproducts without notice. This also applies to products already on order provided that such alterations can be made without subsequential changesbeing necessary in specifications already agreed. All trademarks in this material are property of the respective companies. DEVI and the DEVI logo-type are trademarks of Danfoss A/S. All rights reserved.
0809XXXX & VIGDS102 Produced by Danfoss © 05/2012
D53
4 D
elea
ge
1911
6611
Ther
mos
tat
Room
Sen
sor
Prod
uct D
ocum
enta
tion
Des
igne
d in
Den
mar
k fo
r Dan
foss
A/S
57
03
46
61
85
77
3