Upload
others
View
24
Download
0
Embed Size (px)
Citation preview
TABLE OF CONTENTSET16K(X) (EEAAAA-*0) OWNER'S MANUAL
SECTION 100 DESCRIPTION & SPECIFICATIONS24023 SPECIFICATIONS & OPERATING FEATURES21302 SPECIFICATIONS & OPERATING FEATURES23045 INSTALLATION DIMENSIONS21592 BASE MOUNTING DIMENSIONS21974 CAPACITY CHART19288 TYPICAL REINFORCEMENT FOR MOUNTING CRANE ON TOP OF SERVICE BODY14510 TYPICAL REINFORCEMENT FOR MOUNTING CRANE ON FLAT BED
SECTION 150 SAFETY850711 SAFETY & HAZARDS - GENERAL15394 VEHICLE & CRANE ELECTRIC HAZARD INFORMATION21353 SAFETY DECALS21384 SAFETY DECALS21354 DECALS FOR ET CRANES24017 MODEL & CAPACITY DECALS
SECTION 200 INSTALLATION711105 CABLE & BATTERY REQUIREMENTS - ET & HT CRANES15660 BATTERY & CABLE INSTALLATION DRAWING20906-16 STABILITY TESTING20907 STABILITY CHART22245 WIRE ROPE INSTALLATION
SECTION 300 MAINTENANCE & SERVICE21306 LUBRICATION & MAINTENANCE CHART19963 MINIMUM VOLTAGE TEST23227 WIRE ROPE & HOOK SPECIFICATIONS23084 MANUAL OVERRIDE INSTRUCTIONS
SECTION 400 REPLACEMENT PARTS21796 REPLACEMENT PARTS DRAWING21797 REPLACEMENT PARTS LIST21389 REPLACEMENT FASTENERS LIST21310 21200 BOOM ASSY REPLACEMENT PARTS DRAWING21322 21200 BOOM ASSY REPLACEMENT PARTS LIST21275 21276 ANTI-2-BLOCK REPLACEMENT PARTS DRAWING & LIST21397 23154-1 ELECTRICAL COMPONENT ASSY21388 WIRING DIAGRAM19368 16780 SWIVEL TERMINAL ASSY REPLACEMENT PARTS22076 22060 PENDANT CONTROL REPLACEMENT PARTS DRAWING & LIST23075 21990 PENDANT; REPLACEMENT PARTS DRAWING / LIST (4 FUNCTION)21407 HYDRAULIC SYSTEM COMPONENTS REPLACEMENT PARTS DRAWING20156 HYDRAULIC SYSTEM SCHEMATIC21054 21215 WINCH REPLACEMENT PARTS DRAWING & LIST21973 21735 SLEWING REPLACEMENT PARTS21393 DECAL PLACEMENT20818 24021 FIELD SERVICE LABEL KIT
SECTIONDATE
SUPERSEDES
TITLE
ET16KX (EEAAAA-*0
-02-10-17D
08-04-15C
TABLE OF CONTENTS
24016
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
SECTIONDATE
SUPERSEDES
TITLE
ET16KX (EEAAAA-*0)
C10010-22-14
-
SPECS & OP. FEATURES
24023
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
SPECIFICATIONS & OPERATING FEATURESET16KX (EEAAAA-*0)
SPECIFICATIONS
12 VOLT BATTERY OPERATED
16,000 FT-LBS OVERTURNING MOMENT (or as limited by truck stability)
MOMENT OVERLOAD SYSTEM
WINCH -- 2250 LBS SINGLE LINE CAPACITY WITH AUTOMATIC LOAD BRAKE
ELECTRIC HYDRAULIC BOOM ELEVATION
ELECTRIC HYDRAULIC BOOM EXTENSION & RETRACTION -- 4 FT. STROKE
CONTINUOUS POWER ROTATION
REMOTE CONTROL PENDANT
25 FT straight cord with four [4] environmentally-sealed toggle switches protected by a guard
MASTER DISCONNECT SWITCH
OUTRIGGERS AVAILABLE
Side bracket type outriggers
Fold-away type outriggers
Pullout type outriggers
TELESCOPIC BOOM
BOOM HYD ELEVATION
BOOM HYD EXTENSION
BOOM MANUAL EXT
CAPACITY
WIRE ROPE
PENDANT CORD LENGTH
8 / 16
-8° TO 75°
8 - 12 FT or 12 - 16 FT
4 FT
1125 LBS @16 FT REACH
4500 LBS @2 - 3 FT REACH
516" DIA X 80 FT
25 FT
SECTIONDATE
SUPERSEDES
TITLE
ET16/18KX
C10010-22-14A
07-29-03
SPECS & OP. FEATURES
21302
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
SPECIFICATIONS & OPERATING FEATURESET16/18KX
OVERLOAD SENSING SYSTEMThis crane is equipped with an overload sensing system. If the capacity of the crane is exceeded, the "Winch Up",
Boom Out", and "Boom Out" functions will shut down. The "Winch Down", "Boom Up", and "Boom In" functions will
continue to operate and can be used to relieve the overload condition. The "Rotation" function also will continue to operate.
CONTROL PRIORITY SYSTEM
The design intent of the electrical and hydraulic systems are such that some functions can be operated
simultaneously, while others are meant to be operated individually. To summarize the control system, see the explanations
below:
· Winch Up takes priority over all functions
· Winch Down can be operated with any other single function
· Hydraulic functions (Rotate Right, Rotate Left, Boom Up, Boom Down, Boom Out, and Boom In) are designed to
function one at a time
CABLE DRUM AND SHEAVE DIAMETERS
The drums on the ET16/18KX cranes are 5 1/4" in diameter, which is 18 times the 5/16" wire rope diameter as
required by ANSI B30.15 Hydraulic Crane standards. The cable sheaves are either 16 or 18 times the cable diameter,
which likewise conforms.
MISCELLANEOUS
CAPACITY INDICATOR
Select boom reach and angle allowable for load by using capacity indicator arrow and chart on either side of boom.
BATTERY HOOKUP
A parallel auxiliary battery should be installed near the crane as shown on DWG 19947 under "RECOMMENDED
INSTALLATION." The parallel auxiliary battery minimum rating should be 450 Cold Cranking Amps (at 0° F) and 100
reserve capacity, or 78 plates and 70 amp hours.
C10
0IN
ST
ALL
AT
ION
DIM
EN
SIO
NS
ET
16K
X,E
T18
KX
(GE
NB
)
10-2
2-14
A
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2304
507
-17-
12
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
TO
TA
LIN
ST
ALL
ED
WE
IGH
T10
20LB
S. H
OO
KW
ITH
SA
FE
TY
LAT
CH
TW
OP
AR
TLI
NE
OP
ER
AT
ION
LOA
DB
LOC
KF
OR
165 8"
117 8"
CG
AP
PR
OX
IMA
TE
5/16
DIA
.W
IRE
RO
PE
80F
T.L
ON
G
BO
OM
AN
GLE
AN
DC
AP
AC
ITY
IND
ICA
TO
RO
NB
OT
HS
IDE
SO
FB
OO
M
15"
SW
ING
RA
DIU
S
213
16"
103
16"
265
8"
17'3
14" 13
'41
4" 9'5
14"
4'P
OW
ER
4'M
AN
UA
L
16F
EE
T12
FE
ET
9'11
58"
OA
L8
FE
ET
WA
RN
ING
!
·T
HE
SE
PR
OD
UC
TS
AR
EN
OT
PA
SS
EN
GE
RLI
FT
S.T
HE
YA
RE
NO
TD
ES
IGN
ED
OR
INT
EN
DE
DT
OB
EU
SE
DT
OLI
FT
,SU
PP
OR
TO
RO
TH
ER
WIS
ET
RA
NS
PO
RT
PE
RS
ON
NE
L.
243
8"
SECTIONDATE
SUPERSEDES
TITLE
ET8/12/16/18 CRANES
C10010-22-14F
12-20-13E
21571 BASE MNTNG DIMS
21592
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
CENTERS SHOWN FOR 4x5/8" DIA GRADE 8MOUNTING BOLTS (NOT FURNISHED)TORQUE TO 200 FT*LBS
14"
14"
7"
7"
HOLE LOCATION FORBATTERY CABLEROUTING
BASE PLATE
1" TYP.
12"TYP
Ø3 1/2"
1" TYP
21571 MOUNTING HOLE TEMPLATE
VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
C100MAXIMUM LOAD CAPACITY
ET16KX, 8'-12'-16' BOOM
05-03-16B
DATE SECTION
SUPERSEDES
TITLE
10-20-14A
21974
MAXIMUM LOAD CAPACITY CHART
ET16KX, 8'-12'-16'
CRANE SERIAL NUMBER: ________________
WEIGHT OF LOAD HANDLING DEVICES ARE PART OF THE LOAD AND MUST BE DEDUCTED FROM THE GROSS CAPACITY.
LOAD BLOCK USAGE
1 PART LINE FOR LOADS LESS THAN 2250 LBS
2 PART LINE FOR LOADS OF 2250 LBS AND GREATER
WEIGHT OF LOAD BLOCK = 28 LBS
VE
RT
IC
AL
H
EIG
HT
(F
T)
HORIZONTAL REACH (FT)
2800
1300
1650
1100
1000
9001250
1350
1500
1800
2300
3800
2000
2050
2300
2800
3550
4500
1817161514131211109876543210
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
C10
0T
YP
ICA
LS
ER
VIC
EB
OD
YR
EIN
FO
RC
EM
EN
T
ET
16/1
8KX
10-2
2-14
H
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
1928
812
-20-
10G
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
16"
MIN
/19"
MA
X
SE
CT
ION
A-A
16"
X16
"M
INC
OM
PA
RT
ME
NT
SP
AC
E
SE
CT
ION
B-B
28"
MIN
AA B
B
5
4
3
7
2
5
18
4
2
7
3
6
TR
UC
KF
RA
ME
TY
PIC
AL
SE
RV
ICE
BO
DY
RE
INF
OR
CE
ME
NT
NO
TE
:IT
IST
HE
SO
LE
RE
SP
ON
SIB
ILIT
YO
FT
HE
INS
TA
LL
ER
TO
EN
SU
RE
TH
AT
TH
ET
OT
AL
ST
RU
CT
UR
EO
FC
RA
NE
,TR
UC
K,A
ND
ST
AB
ILIZ
ER
SA
RE
ST
RU
CT
UR
AL
LY
SO
UN
DA
ND
TH
AT
TH
EC
OM
PL
ET
ED
VE
HIC
LE
HA
SS
UF
FIC
IEN
TS
TA
BIL
ITY
AG
AIN
ST
OV
ER
TU
RN
ING
.
ITE
M
1 2 3 4 5 6 7 8
DE
SC
RIP
TIO
N
TO
PP
LAT
EC
OR
NE
RP
OS
TC
RO
SS
FR
AM
ES
HE
AR
WE
BT
OP
PLT
RE
INF
OR
CE
ME
NT
OU
TR
IGG
ER
RN
FR
CM
NT
PLT
GU
SS
ET
BO
DY
TO
PR
EIN
FO
RC
EM
EN
T
MIN
IMU
MR
EC
OM
ME
ND
ED
MA
TE
RIA
LS
IZE
1/2"
ST
EE
L3"
X3"
X1/
2"S
TE
EL
AN
GLE
4"X
4"X
5/16
"S
QU
AR
ET
UB
ING
,SP
AN
FU
LLW
IDT
H3/
16"
ST
EE
LP
LAT
E1/
2"X
6"O
R3/
4"X
5"S
TE
EL
BA
R1/
4"T
HIC
KS
TE
EL
PLA
TE
1/2"
X4"
H.R
.ST
EE
L10
GA
SM
OO
TH
OR
DIA
MO
ND
PLA
TE
W/1
"LI
PO
VE
RS
IDE
OF
BO
DY
C10
0T
YP
ICA
LF
LAT
BE
DM
NT
NG
RE
INF
OR
EC
ME
NT
ET
16/1
8KX
10-2
2-14
N
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
1451
007
-29-
03M
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
TY
PIC
AL
FLA
TB
ED
MO
UN
TIN
GR
EIN
FO
RC
EM
EN
T
NO
TE
:IT
IST
HE
SO
LE
RE
SP
ON
SIB
ILIT
YO
FT
HE
INS
TA
LL
ER
TO
EN
SU
RE
TH
AT
TH
ET
OT
AL
ST
RU
CT
UR
EO
FC
RA
NE
,TR
UC
K,A
ND
ST
AB
ILIZ
ER
SA
RE
ST
RU
CT
UR
AL
LY
SO
UN
DA
ND
TH
AT
TH
EC
OM
PL
ET
ED
VE
HIC
LE
HA
SS
UF
FIC
IEN
TS
TA
BIL
ITY
AG
AIN
ST
OV
ER
TU
RN
ING
.
TH
ISB
OLT
PA
TT
ER
NF
OR
DIR
EC
TM
OU
NT
ING
OF
TH
EE
T25
K(X
)C
RA
NE
.S
EE
DW
G19
411
FO
RP
ED
ES
TA
LM
OU
NT
ING
BO
LTP
AT
TE
RN
.
PE
RIM
ET
ER
RA
IL
12
x4
x17
AT
TA
CH
TO
PE
RIM
ET
ER
RA
IL
PR
OV
IDE
ST
RU
CT
UR
AL
AT
TA
CH
ME
NT
BE
TW
EE
NR
EIN
FO
RC
EM
EN
T&
ST
AB
ILIZ
ER
5"H
OLE
FO
RH
YD
RA
ULI
C/E
LEC
TR
ICC
ON
NE
CT
ION
S-
ET
/HT
18/2
5K(X
)1
4P
LAT
EW
ELD
ED
TO
LON
GS
ILLS
&B
OLT
ED
TO
FR
AM
E
LON
GS
ILLS
3x
3x
38
3x
3x
38
AN
GLE
SB
OLT
ED
INT
OF
RA
ME
&LO
NG
SIL
LS-
2P
LAC
ES
12
x3
x16
PLA
TE
S4x
21
2x
12
-13
.8LB
S./F
T.
SH
IP&
CA
RC
HA
NN
EL
12
x12
x20
PLA
TE
S
APP
RO
X.
36
SECTIONDATE
SUPERSEDES
TITLE
ELECTRIC CRANES
C15001-29-15K
12-20-13J
SAFETY & HAZARDS
850711
CRANE SAFETY AND HAZARDSCAUTIONS1. INSPECT VEHICLE AND CRANE, INCLUDING OPERATION, PRIOR TO USE DAILY.2. DO NOT USE THIS EQUIPMENT EXCEPT ON FIRM LEVEL GROUND WITH CRANE MOUNTED ON
FACTORY-RECOMMENDED TRUCK.3. BEFORE OPERATING THE CRANE, REFER TO MAXIMUM LOAD (CAPACITY) CHART ON CRANE FOR
OPERATING (LOAD) LIMITATIONS.4. DO NOT OPERATE, WALK, OR STAND BENEATH BOOM OR A SUSPENDED LOAD.5. ATTACH PENDANT CORD SUPPORT SNAP TO ATTACHMENT POINT BEFORE PLUGGING IN PENDANT, IF SO
EQUIPPED.6. UNPLUG PENDANT AND SHUT OFF MASTER DISCONNECT SWITCH WHEN CRANE IS NOT IN USE.7. FOR TRAVEL, BOOM MUST BE IN STOWED POSITION.
DANGER· THIS CRANE IS NOT A PASSENGER LIFT· IT IS NOT DESIGNED OR INTENDED TO BE USED TO LIFT, SUPPORT, OR OTHERWISE TRANSPORT
PERSONNEL.
YOU MUST NOT OPERATE THIS CRANE, UNLESS:1. YOU HAVE BEEN TRAINED IN THE SAFE OPERATION OF THIS CRANE, AND2. YOU KNOW AND FOLLOW THE SAFETY AND OPERATING RECOMMENDATIONSCONTAINED IN THE
MANUFACTURER'S MANUALS, YOUR EMPLOYER'S WORK RULES, AND APPLICABLE GOVERNMENTREGULATIONS. AN UNTRAINED OPERATOR SUBJECTS HIMSELF AND OTHERS TO DEATH OR SERIOUSINJURY.
ELECTROCUTION HAZARD· THIS MACHINE IS NOT INSULATED.· MAINTAIN SAFE CLEARANCES FROM ELECTRICAL LINES AND APPARATUSES.· YOU MUST ALLOW FOR BOOM SWAY, ROCK, OR SAG, AND ELECTRICAL LINE AND LOAD-LINE SWAYING· THIS LIFTING DEVICE DOES NOT PROVIDE PROTECTION FROM CONTACT WITH OR PROXIMITY TO AN
ELECTRICALLY CHARGED CONDUCTOR.· YOU MUST MAINTAIN A CLEARANCE OF AT LEAST 10 FEET BETWEEN ANY PART OF THE CRANE, LOAD-LINE,
OR LOAD, AND ANY ELECTRICAL LINE OR APPARATUS CARRYING UP TO 50,000 VOLTS. REFER TO DRAWING15394 FOR ADDITIONAL INFORMATION.
· WILL RESULT FROM CONTACT OR INADEQUATE CLEARANCES.
OVERLOAD SENSING SYSTEM - STANDARD ON ALL CRANES
1. IF OVERLOADED, THE WINCH UP, BOOM DOWN, AND (OPTIONAL) BOOM OUTFUNCTIONS WILL AUTOMATICALLY, SHUT OFF TO PREVENT INCREASED OVERLOAD.
2. ON CRANES EQUIPPED WITH AN OPTIONAL OVERLOAD ALARM, IT WILL ALSO SOUND.3. IF AN OVERLOAD OCCURS, USE THE WINCH DOWN, BOOM UP OR BOOM IN
FUNCTIONS TO RELIEVE THE OVERLOAD.4. THE OVERLOAD SENSING SYSTEM IS INOPERATIVE IF THE BOOM ELEVATION IS AT THE
BOTTOM OR TOP LIMIT OF TRAVEL. TO RELIEVE THIS CONDITION, RAISE OR LOWERTHE BOOM SLIGHTLY BEFORE LIFTING THE LOAD.
5. SEE MANUAL FOR TESTING THE OVERLOAD SYSTEM.
NOTICE - WARRANTY VOID IF DISCONNECTEDTHE OVERLOAD SENSING SYSTEM HAS BEEN INSTALLED AS A SAFETY FEATURE TO PROTECT THE
EQUIPMENT AND THE OPERATOR.
DO NOT DISCONNECT THIS SYSTEM
DEATH OR SERIOUS INJURY
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
SECTIONDATE
SUPERSEDES
TITLE
ELECTRIC CRANES
C15001-29-15
-
SAFETY & HZRDS, CONT.
850712
CRANE SAFETY AND HAZARDS - CONT'D
OVERLOAD ALARM SYSTEM - OPTIONAL
1. OVERLOAD ALARM HORN SOUNDS IF RATED LOAD IS EXCEEDED AT ANY REACH.
2. IF ALARM SOUNDS, RAISE BOOM OR LOWER WINCH TO REMOVE OVERLOAD.
3. ALWAYS RAISE BOOM SLIGHTLY BEFORE LIFTING LOAD. WARNING SYSTEM INOPERATIVE WHEN CYLINDER ISCOMPLETED BOTTOMED.
4. ALARM CAN BE TESTED BY TYING DOWN BOOM WITH WINCH CABLE AND OPERATING BOOM UP OR BYRAISING BOOM AGAINST UP LIMIT STOP.
NOTICE - WARRANTY VOID IF DISCONNECTED
THIS ALARM SYSTEM HAS BEEN INSTALLED AS A SAFETY FEATURE TO PROTECT BOTH THE EQUIPMENT ANDTHE OPERATOR.
DO NOT DISCONNECT THIS SYSTEM
INTENTIONALLY LEFT BLANK
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
SECTIONDATE
SUPERSEDES
TITLE
ET/HT CRANES
C15002-21-14M
12-20-13L
HAZARD APPS & INFO
15394
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
SIGN NO. 15393 DISPLAYS THE INTERNATIONAL SYMBOLFOR ELECTRICITY AND WARNS OF DANGER FROM ANELECTRICALLY CHARGED VEHICLE, CRANE, OR LOAD.FOUR ARE RECOMMENDED (ONE FOR EACH SIDE ANDONE FOR EACH END OF VEHICLE) TO BE APPLIED INLOCATIONS WHICH ARE READILY VISIBLE TO GROUNDPERSONNEL.
SIGN NO. 15401 PROVIDES ADDITIONALWARNING OF LEGAL REQUIREMENTS WHENOPERATING NEAR HIGH VOLTAGE LINES. THISSIGN IS PLACED ON THE CONTROL PENDANTSIDE OF BOOM.
Table A - Minimum Clearance Distances
Voltage Minimum clearance distance(nominal, kV, alternating current) (feet) *
Up to 50............................................................................................... 10over 50 - 200....................................................................................... 15over 200 - 350..................................................................................... 20over 350 - 500..................................................................................... 25over 500 - 750..................................................................................... 35over 750 - 1000................................................................................... 45
Table T - Minimum Clearance Distances While Traveling With No Load
Voltage While traveling - minimum clearance distance(nominal, kV, alternating current) (feet) *
0 - 0.75........................................................................................... 4over 0.75 - 50.................................................................................. 6over 50 - 345................................................................................... 10over 345 - 750................................................................................. 16over 750 - 1000............................................................................... 20Over 1000...................................................................................... (as established by the utility owner/operator or registered
professional engineer who is a qualified person with respect toelectrical power transmission and distribution).
* NOTE: ENVIRONMENTAL CONDITIONS SUCH AS FOG, SMOKE, OR PRECIPITATION MAY REQUIRE INCREASED CLEARANCES
Over 1000........................................................................................... (as established by the utility owner/operator or registeredprofessional engineer who is a qualified person withrespect to electrical power transmission and distribution).
ELECTROCUTION HAZARDKEEP CLEAR OF TRUCK AND LOADDEATH OR SERIOUS INJURY CAN RESULT FROM
CONTACT WITH THE LOAD, THE CRANE, OR THEVEHICLE IF BOOM OR LOAD LINE SHOULD BECOME
ELECTRICALLY CHARGED.15393-C
! DANGER
D A N G E R!UNLAWFUL TO OPERATE THIS EQUIPMENT
WITHIN 20 FEET OF HIGH-VOLTAGE LINESOF 350,000 VOLTS OR LESS.
FOR MINIMUM CLEARANCES OF HIGH-VOLTAGE LINES IN EXCESS OF 350,000 VOLTS, REFERENCE OSHA 1926.1408,CRANE'S SAFETY MANUAL, AND CAL-OSHA ARTICLE 37, TITLE 8, HIGH-VOLTAGE ELECTRICAL SAFETY ORDERS .
15401-D
VEHICLE & CRANE MOUNTED ELECTRICALHAZARD SIGN APPLICATION & INFORMATION
VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
C150SAFETY DECALS
VENTURO CRANES
04-29-16E
DATE SECTION
SUPERSEDES
TITLE
10-24-13D
21353
DECAL #: 15390
DESCRIPTION: CAUTION, INSPECT VEHICLE & CRANE...
PURPOSE: TO INFORM THE OPERATOR OF KEY OPERATING REQUIREMENTS.
QUANTITY: 1
PLACEMENT: REAR COVER OR SIDE OF CRANE
DECAL #: 15391
DESCRIPTION: DANGER, NOT A PASSENGER LIFT
PURPOSE: TO INFORM OPERATOR NOT TO LIFT, SUPPORT, OR TRANSPORT
PERSONNEL, AND TO ENSURE OPERATOR IS ADEQUATELY TRAINED.
QUANTITY: 1
PLACEMENT: REAR COVER OR SIDE OF CRANE
15390-D
!CAUTION
1. INSPECT VEHICLE AND CRANE INCLUDING
OPERATION, PRIOR TO USE DAILY.
2. DO NOT USE THIS EQUIPMENT EXCEPT ON
SOLID, LEVEL SURFACE WITH CRANE
MOUNTED ON FACTORY-RECOMMENDED
TRUCK.
3. BEFORE OPERATING THE CRANE, REFER TO
MAXIMUM LOAD (CAPACITY) CHART ON CRANE
FOR OPERATING (LOAD) LIMITATIONS.
4. DO NOT OPERATE, WALK, OR STAND BENEATH
BOOM OR A SUSPENDED LOAD.
5. UNPLUG PENDANT AND SHUT OFF MASTER
DISCONNECT SWITCH WHEN CRANE NOT IN
USE.
6. FOR TRAVEL, BOOM MUST BE IN STOWED
POSITION.
DANGER!THIS CRANE IS NOT A PASSENGER LIFT
IT IS NOT DESIGNED OR INTENDED TO BE USED TO LIFT,
SUPPORT OR OTHERWISE TRANSPORT PERSONNEL.
YOU MUST NOT
OPERATE THIS CRANE UNLESS:
1. YOU HAVE BEEN TRAINED IN THE SAFE
OPERATION OF THIS CRANE; AND
2. YOU KNOW AND FOLLOW THE SAFETY AND
OPERATING RECOMMENDATIONS CONTAINED IN
THE MANUFACTURER'S MANUALS, YOUR
EMPLOYER'S WORK RULES, AND APPLICABLE
GOVERNMENT REGULATIONS.
AN UNTRAINED OPERATOR SUBJECTS HIMSELF
AND OTHERS TO DEATH OR SERIOUS INJURY .
15391-D
THIS MACHINE IS NOT INSULATED
ELECTROCUTION HAZARD
MAINTAIN SAFE CLEARANCES FROM ELECTRICAL
LINES AND APPARATUS. YOU MUST ALLOW FOR
BOOM SWAY, ROCK OR SAG, AND ELECTRICAL
LINE AND LOAD LINE SWAYING.
THIS LIFTING DEVICE DOES NOT PROVIDE PRO-
TECTION FROM CONTACT WITH OR PROXIMITY
TO AN ELECTRICALLY CHARGED CONDUCTOR.
YOU MUST MAINTAIN A CLEARANCE OR AT LEAST
10 FEET BETWEEN ANY PART OF THE CRANE, LOAD
LINE OR LOAD, AND ANY ELECTRICAL LINE OR
APPARATUS CARRYING UP TO 50,000 VOLTS. ONE
FOOT ADDITIONAL CLEARANCE IS REQUIRED FOR
EVERY ADDITIONAL 30,000 VOLTS OR LESS.
DEATH OR SERIOUS INJURY WILL RESULT FROM
CONTACT OR INADEQUATE CLEARANCE.
15392-E
DANGER!
D A N G E R!
UNLAWFUL TO OPERATE THIS EQUIPMENT
WITHIN 20 FEET OF HIGH-VOLTAGE LINES
OF 350,000 VOLTS OR LESS.
FOR MINIMUM CLEARANCES OF HIGH-VOLTAGE LINES IN EXCESS OF 350,000 VOLTS, REFERENCE OSHA 1926.1408,
CRANE'S SAFETY MANUAL, AND CAL-OSHA ARTICLE 37, TITLE 8, HIGH-VOLTAGE ELECTRICAL SAFETY ORDERS.
15401-D
ELECTROCUTION HAZARD
KEEP CLEAR OF TRUCK AND LOAD
DEATH OR SERIOUS INJURY CAN RESULT FROM
CONTACT WITH THE LOAD, THE CRANE, OR THE
VEHICLE IF BOOM OR LOAD LINE SHOULD BECOME
ELECTRICALLY CHARGED.
15393-C
!DANGER
DECAL #: 15392
DESCRIPTION: DANGER, ELECTROCUTION HAZARD, MACHINE (CRANE)
PURPOSE: TO INFORM OPERATOR THAT MACHINE (CRANE) REPRESENTS AN
ELECTROCUTION HAZARD SHOULD IT COME CLOSE TO OR IN CONTACT
WITH AN ELECTRICAL VOLTAGE SOURCE.
QUANTITY: 1
PLACEMENT: REAR COVER OR SIDE OF CRANE
DECAL #: 15401
DESCRIPTION: DANGER, UNLAWFUL TO OPERATE
PURPOSE: TO INFORM OPERATOR OF PROPER OPERATION
IN VICINITY OF ELECTRICAL LINES.
QUANTITY: 1
PLACEMENT: RING COVER OR SIDE OF CRANE
DECAL #: 15393
DESCRIPTION: DANGER, ELECTROCUTION HAZARD, VEHICLE (TRUCK)
PURPOSE: WARNS OF DANGER FROM ELECTRICALLY CHARGED
VEHICLE, CRANE, OR LOAD.
QUANTITY: 4
PLACEMENT: EACH SIDE & EACH END OF VEHICLE
PART NO.: 15513
DECAL: MASTER DISCONNECT SWITCH
FUNCTION: To inform the operator of locationand operation of master disconnectswitch.
QUANTITY: 1
PLACEMENT: On master disconnect switch bracket.
SECTIONDATE
SUPERSEDES
TITLE
CRANES
C15006-06-14C
04-02-13B
SAFETY DECALS
21384
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
PART NO.: 20927
DECAL: CRANE STABILITY
FUNCTION: To inform the operator of the crane's liftingcapacity throughout the entire rotation.
QUANTITY: 1
PLACEMENT: In prominent location, so it is easily seen andreadily identifiable.
%
%
%
%
%%
%
%
%
%
NO LIFTING
S T A B I L I T Y C H A R T
20927
PERMITTED IN THIS AREA
ZONE 1ZONE 10
ZONE 9
ZONE 8
ZONE 2
ZONE 3
ZONE 4
ZONE 5ZONE 6
ZONE 7
D BASED UPON THE FINAL INSTALLED PACKAGE, THIS CRANE MAY NOT BE ABLE TOLIFT TO FULL CAPACITY THROUGHOUT THE ENTIRE CRANE ROTATION. REFER TOTHE DIAGRAM BELOW, ALONG WITH THE CRANE'S LOAD CHART, TO DETERMINE THEMAXIMUM CAPACITY FOR VARIOUS ROTATION ZONES.
FAILURE TO DO SO MAY RESULT IN SERIOUS INJURY OR DEATH
D A N G E R
SECTIONDATE
SUPERSEDES
TITLE
ET CRANES
C15012-23-13D
04-19-13C
DECALS
21354
®MANUFACTURING, INC.
CINCINNATI, OHIO
PART NO.: 15398
DECAL: UNPLUG REMOTE CONTROL
FUNCTION: To inform the operator to unplug remotecontrol when not in use.
QUANTITY: 1
PLACEMENT: Near pendant socket.
PART NO.: 13397
DECAL: OIL LEVEL
FUNCTION: To inform the operator of proper oil level tomaintain.
QUANTITY: 1
PLACEMENT: Side of hydraulic power unit.
PART NO.: 14473-2
DECAL: GREASE
FUNCTION: To show the operator where to apply grease.
QUANTITY: Varies
PLACEMENT: Near grease fittings.
1447
3-2-
D
GREASE
1339
7-E
Retract All CylindersPrior to Servicing
AW46 or DEXRON III ATF
OIL LEVEL
UNPLUGREMOTE CONTROL
PENDANT WHENNOT IN USE
15398-F
SECTIONDATE
SUPERSEDES
TITLE
ET16KX
-10-17-14
-
MODEL/CAPCTY DECALS
24017
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
PART NO.: 24018-1 & 24018-2
DECAL: CRANE CAPACITY
FUNCTION: To show the operator the operatingcapacities of crane.
QUANTITY: 1 each
PLACEMENT: One on each side of boom.
PART NO.: 24019
DECAL: MODEL NUMBER (ET18KX)
FUNCTION: To show the model of the crane.
QUANTITY: 2
PLACEMENT: One on each side of boom.
PART NO.: 27007-05a
DECAL: LOAD BLOCK CAPACITY
FUNCTION: To show the capacity of the load block.
QUANTITY: 2
PLACEMENT: One on each side of load block.
WEIGHT:
28 lbsRATED CAPACITY:
4,500 lbs
LOAD BLOCK SPECIFICATIONS
2700
7-05
aWARNING:1 PART LINE FOR LOADS LESS THAN 2250 LBS.
2 PART LINE FOR LOADS 2250 LBS. & GREATER
20002050
2300
2800
3550
4500
12501350
1500
1800
2300
3800
28001650
13001100
1000 900
0°
75°60°
45°30° 15°
16 FT.
12 FT.8 FT.
I FT
I NG
L
CAPAC
I TY
LN
BS .
I
ET/HT16KX8-12-16
FT. BOOM
BO
OM
ANGL E
NOTEUSE
LOAD BLOCKFOR LOADS
OVER 2250 LBS.
BOOMLENGTH
24018-1
0°
75°
60°
45°
30°15°
16 FT.
12 FT.8 FT.
I F T I NG
L
CAPACI TY
LN
BS
.
I
24018-2
ET/HT16K(X)8-12-16
FT. BOOM
BOOMAN
GL
E
NOTEUSE
LOAD BLOCKFOR LOADS
OVER 2250 LBS.
BOOMLENGTH
20001250
900
2050 230028
00
3550
4500
1350 150018
00
2300
3800
2800
1650
1300
1100
1000
SECTIONDATE
SUPERSEDES
TITLE
ELECTRIC CRANES
C20007-30-18X
09-27-17W
CABLE & BATTERY
711105
!! IMPORTANT !!
ADEQUATE WIRING IMPERATIVE FOR PROPER OPERATION
1. PROPER GROUND PATH - SEE DWG 15660
2. CURRENT DRAW IS SEVERAL HUNDRED AMPERES -ADEQUATE WIRE SIZE AND BATTERY CAPACITY ISABSOLUTELY ESSENTIAL (SEE CHART BELOW).
MINIMUM WIRE GAUGE AND AUXILIARY BATTERY SIZE
MODEL
CE1500CE6KCT2000CT2003/4/5DT7K
ET5500MPBET5500RET6KMPBET6KRET6KET8KET10KET12K
ET8KXET10KXET12KXET12KXP
ET18K(X)ET25K(X)ET30KXET36KX
TOTAL LENGTH OF CABLE (FT) *
0-20 21-25 26-30 31-40 41-50 51-60 61-70 71-80
#4 #4 #2 #2 #1 #0 #0 #00
#2 #2 #1 #0 #00 NOT RECOMMENDED
#2 #2 #1 #0 #00 NOT RECOMMENDED
SEE DRAWING 15660 FOR CABLE AND BATTERYREQUIREMENTS
12 VOLT AUXILIARYBATTERY REQUIREMENTS
CCA (A) ** RC (MIN) ***
350 100
450 100
550 150
* INCLUDES GROUND CABLE
** CCA = COLD CRANKING AMPS AT 0° (F).
*** RC = RESERVE CAPACITY IN MINUTES AT 25 AMPS AND 80° (F).THE RC RATING IS A MEASURE OF THE PERIOD OF TIME THE BATTERY CAN
SUPPLY A GIVEN CURRENT WITHOUT RECHARGING.
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
C2
00
BA
TT
ER
YC
AB
LE
&C
OM
PO
NE
NT
INS
TA
LL
ET
CR
AN
ES
07-3
0-1
8L
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
15660
07-3
1-1
5K
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLLC
CIN
CIN
NA
TI,
OH
IO
+1
2V
TR
UC
KB
AT
TE
RY
-N
EG
RE
CO
MM
EN
DE
DO
PT
ION
:C
IRC
UIT
BR
EA
KE
RO
RF
US
E;
LO
CA
TE
CL
OS
ET
OT
RU
CK
BA
TT
ER
Y(S
EE
CH
AR
TA
MP
RA
TIN
G)
+1
2V
-N
EG
RE
CO
MM
EN
DE
D(N
OT
INC
LU
DE
D)
AU
XIL
IAR
YC
RA
NE
BA
TT
ER
Y
TR
UC
KF
RA
ME
TR
UC
KF
RA
ME
MA
ST
ER
DIS
CO
NN
EC
TS
WIT
CH
(IN
CL
UD
ED
)(L
OC
AT
EF
OR
OP
TIM
UM
OP
ER
AT
OR
AC
CE
SS
AS
CL
OS
ET
OT
HE
CR
AN
EA
SP
RA
CT
ICA
L)
#2
GA
UG
Ex
5'B
LA
CK
GR
OU
ND
ING
ST
RA
P(I
NC
LU
DE
D)
#2
GA
UG
Ex
5'R
ED
+1
2V
BA
TT
ER
YC
AB
LE
(IN
CL
UD
ED
)
#2
GA
UG
EX
26'
BA
TT
ER
YC
AB
LE
(IN
CL
UD
ED
)
INS
TA
LL
#2
GA
UG
EG
RO
UN
DS
TR
AP
FR
OM
EN
GIN
ET
OT
RU
CK
FR
AM
E(R
EQ
UIR
ED
IFN
EG
AT
IVE
FR
OM
BA
TT
ER
YIS
CO
NN
EC
TE
DT
OE
NG
INE
EN
GIN
E
BA
TT
ER
YR
EQ
UIR
EM
EN
TS
·1
2V
OL
TV
EH
ICL
EB
AT
TE
RY
RE
QU
IRE
ME
NT
S··
62
5C
OL
DC
RA
NK
ING
AM
PS
(AT
0º
F)
··1
60
MIN
UT
ES
RE
SE
RV
EC
AP
AC
ITY
··1
02
PL
AT
ES
,1
05
AM
P-H
R
·1
2V
OL
TA
UX
ILIA
RY
BA
TT
ER
YR
EQ
UIR
EM
EN
TS
··S
EE
MIN
IMU
MW
IRE
GA
UG
EA
ND
BA
TT
ER
YS
IZE
NO
TE
:O
PE
RA
TIN
GW
ITH
TH
EV
EH
ICL
EB
AT
TE
RY
'ON
LY
'IS
PE
RM
ISS
IBL
E,B
UT
NO
TR
EC
OM
ME
ND
ED
.
VE
NT
UR
OC
AB
LE
5/1
6x
1-1
/2B
OLT
OR
IGIN
AL
CA
BLE
GR
OU
ND
CR
AN
ET
OT
RU
CK
FR
AM
E
RE
CO
MM
EN
DE
DB
AT
TE
RY
TE
RM
INA
LA
TT
AC
HM
EN
T BA
TT
ER
YP
OS
T
CR
AN
E
NO
TE
:A
LS
OS
EE
DR
AW
ING
71
11
05
FO
RA
DD
ITIO
NA
LIN
FO
RM
AT
ION
ON
BA
TT
ER
YW
IRE
GA
UG
E&
LE
NG
TH
(1)
(1)
RE
CO
MM
EN
DE
DC
IRC
UIT
BR
EA
KE
RT
AB
LE
CR
AN
ED
ES
CR
IPT
ION
PA
RT
NO
.
CT
310
KX
250
AM
P,
MA
NR
ES
ET
229
46
-250
DT
72
50
AM
P,
MA
NR
ES
ET
229
46
-250
CE
-15
00-F
B1
50
AM
P,
MA
NR
ES
ET
229
46
-150
CE
6K
150
AM
P,
MA
NR
ES
ET
229
46
-150
CT
200X
250
AM
P,
MA
NR
ES
ET
229
46
-250
ET
6K
250
AM
P,
MA
NR
ES
ET
229
46
-250
ET
8/1
2K
(X)
250
AM
P,
MA
NR
ES
ET
229
46
-250
ET
12K
XP
250
AM
P,
MA
NR
ES
ET
229
46
-250
ET
16/1
8K
X2
50
AM
P,
MA
NR
ES
ET
229
46
-250
ET
25/3
0K
X3
00
AM
P,
AU
TO
RE
SE
T2
29
46
-300
ET
36K
X3
00
AM
P,
AU
TO
RE
SE
T2
29
46
-300
SECTIONDATE
SUPERSEDES
TITLE
ET16KX
C20010-17-14
-
STABILITY TEST
20906-16
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
Overview
Venturo follows the guidelines of ANSI B30.5 in defining stability. Generally speaking, a truck is considered stable aslong as it is not on the verge of tipping - i.e. with the truck level, at least one tire on each corner of the truck mustremain in contact with the ground.
It is important to note that nearly every installation is unique and will, therefore, typically require stability testing.
The procedure outlined below follows ANSI's (B30.5 - 5-1.1.1) specified "maximum load rating" of 85%.
Testing Procedure
1. Locate the truck on firm level ground, and set parking brake.
2. Fully deploy stabilizers, making sure they are firmly in contact with supportive ground; use stabilizer pads asrequired. The tires of the truck should remain in full contact with the ground.
3. Inspect wire rope and other key components of crane (consult owners manual for more information).
4. Conduct an operational check of all crane functions.
5. Use a test weight of 1035 lbs in conjunction with the ET16KX's load block (weight = 30 lb).
6. Do NOT allow the weight to be more than 6 inches from the ground at any time during testing - this insures thatif the truck does become unstable and tip, it will not tip far.
7. Rotate the crane to a position between 1 and 2 o'clock (the truck cab is facing 12 o'clock).
8. Be sure that the boom is horizontal (0° elevation) with the hydraulic section fully retracted and the manualsection fully extended; the boom should begin at a length of 12 feet.
9. Use the winch to lift the test weight, keeping it within 6 inches of the ground.
10. Extend the boom slowly until the boom reaches full extension ( 192 inches) or until the truck becomes unstable.As you extend, use the winch to keep the weight within 6 inches of the ground.
a. If the boom reaches full extension, the % of Rated Capacity is 100% for the tested region.b. If, however, the truck becomes unstable (tire(s) leave the ground) prior to full extension, record (in
inches) the horizontal distance from the center of rotation to the wirerope at this point (e.g. 180 inches).This is the Maximum Stable Reach. Determine the % of Rated Capacity using the following formula:
11. Record the % of Rated Capacity in the appropriate blank on the Crane Stability chart and/or decal.
12. Repeat Steps 7-11 for each of the remaining regions (2-3 o'clock, 3-4 o'clock, etc.).
% Rated Capacity ="Max. Stable Reach" in inches
192x 100
STABILITY TEST - ET16KX
SECTIONDATE
SUPERSEDES
TITLE
VENTURO CRANES
C20005-11-17F
02-21-14E
STABILITY CHART
20907
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
CONDITIONS:
CRANE STABILITY
%
0°
%
30°
%
60°
90°
%
%%
60°%
90°
%
120°
%
120°%
150°
· STABILIZERS FULLY EXTENDED & DOWN,ON FIRM LEVEL GROUND.
% of Rated Capacity for each of the 10 regions are provided above.
30°
150°N OL I F T I N G P E R M I T T E DI N T H I S A R E A
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5ZONE 6
ZONE 7
ZONE 8
ZONE 9
ZONE 10
SECTIONDATE
SUPERSEDES
TITLE
ET6K & LARGER CRANES
C20002-21-14K
12-26-13J
WIRE ROPE INSTALLTN
22245
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
WIRE ROPE INSTALLATION
M
STEP 1: UNWIND COIL OF WIRE ROPE BY 'ROLLING' ALONG THE FLOOR. THIS WILLPREVENT 'KINKING'.
STEP 2: INSERT WIRE ROPE END UP THROUGH ANTI-2-BLOCK (A2B) CAGE ASSEMBLY,BETWEEN CHEEK PLATES, OVER THE TOP SHEAVE, AND THROUGH WIREROPE GUIDE.
STEP 3: INSERT WIRE ROPE END INTO POCKET OPENING ON WINCH, WRAP AROUNDWEDGE, AND BACK THROUGH POCKET OPENING AS SHOWN IN FIGURE 1.
CAUTIOND IF THE WIRE ROPE IS NOT
INSTALLED FOR THECORRECT DRUM ROTATION,THE WINCH BRAKE VALVEWILL NOT HOLD THE LOAD.
CAUTIOND THERE MUST ALWAYS BE AT
LEAST [5] DEAD WRAPS OFWIRE ROPE ON THE WINCHDRUM WHILE UNDER LOAD.
NOTE: SOME WINCHES MAY BE SUPPLIED WITH A HEX NUT IN LIEU OF A WEDGE FORINSTALLING THE WIRE ROPE.
FIG. 1
C3
00
LU
BR
ICA
TIO
N&
MA
INT
EN
AC
EC
HA
RT
ET
8/1
2/1
6/1
8S
ER
IES
CR
AN
ES
03-0
8-1
9J
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
21306
11-1
8-1
4H
Serv
ice
Inte
rval
Note
Lo
cation
Serv
ice
Req
uired
Tim
eof
Tru
ck
Serv
ice
Use
FU
CH
SR
en
olit
Alu
min
um
Co
mple
xG
rease
,or
equiv
ale
nt
Gre
ase
fittin
gW
ith
Pre
ssure
Gre
ase
Gun
A
Tim
eof
Tru
ck
Serv
ice
Tim
eof
Tru
ck
Serv
ice
Lu
bri
cate
Gea
rT
eeth
B C DR
op
esho
uld
be
free
of
kin
ks
an
dfr
ayi
ng
Che
ck
Wir
eR
op
eand
Hook
Rem
ove
Cover
&U
se
Chass
isG
rease
1A
LIG
NM
EN
T:
To
alig
nho
lew
/fittin
g,lin
eup
gre
ase
de
cals
on
low
er
cover
an
dba
seguss
et.
AT
TE
NT
ION
:N
EV
ER
WA
SH
TH
ISC
RA
NE
WIT
HC
HE
MIC
AL
PR
OD
UC
TS
OR
HIG
HP
RE
SS
UR
EW
AT
ER
JET
S,
AS
TH
EY
CA
NC
AU
SE
DE
TA
CH
ME
NT
OF
DE
CA
LS
OR
EN
TR
AN
CE
OF
WA
TE
RIN
TO
EL
EC
TR
ICA
LO
RS
LE
WIN
GR
ING
CO
MP
ON
EN
TS
Use
Dextr
on
AT
Ffo
rA
mbie
nt
Tem
pe
ratu
res
Betw
ee
n-2
2°
Fand
30
°F
Use
ISO
Vis
cosi
tyG
rad
e68
or
Equ
ivale
nt
for
Am
bie
nt
Tem
pe
ratu
res
Betw
een
10
°Fan
d12
5°F
Tim
eof
Tru
ck
Serv
ice
an
das
req
uir
ed
by
cha
ng
es
inth
eam
bie
nt
tem
pe
ratu
rera
nge
C
DA
A
B
Fill
Oil
Reserv
oir
toO
ilLe
velw
ith
Boom
Dow
nand
Boo
mIn
.
13397-E
Ret
ract
All
Cyl
inde
rsP
rio
rto
Ser
vici
ng
AW
46
orD
EX
RO
NIII
AT
F
OIL
LE
VE
L GR
EA
SE
GREASE
GREASE
GR
EA
SE
1E
T1
8K
XS
HO
WN
FO
RR
EF
ER
EN
CE
14473-2-D
GR
EA
SE
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLLC
CIN
CIN
NA
TI,
OH
IO
Tim
eof
Tru
ck
Serv
ice
EB
olts
sho
uld
be
torq
ued
to20
0ft-lbs
Che
ck
Torq
ue
ofbolts
E
SECTIONDATE
SUPERSEDES
TITLE
ET SERIES CRANES
C30012-26-13G
10-05-09F
MINIMUM VOLTAGE TEST
19963
®MANUFACTURING, INC.
CINCINNATI, OHIO
ONE OF THE MOST COMMON ELECTRICAL PROBLEMS ENCOUNTERED ON12 VOLT ELECTRICAL CRANES IS INSUFFICIENT VOLTAGE AT THE MOTOR
WHEN DRAWING THE LARGE CURRENT THAT EXISTS AT FULL LOAD
EXTEND BOOM CYLINDERAGAINST "UP" STOP
(RELIEF VALVE WILL OPEN)
VOLTAGE AT MOTOR TERMINALWHEN OPERATING AGAINST RELIEF
VALVE SHOULD BE A MINMUM OF9 VOLTS
BOOM ELEVATINGELECTRIC HYDRAULIC
POWER UNIT
MINIMUM VOLTAGE TEST
WIR
E R
OP
E A
SS
EM
BLY
VE
NC
O V
EN
TU
RO
IN
DU
ST
RIE
S LLC
CIN
CIN
NA
TI, O
HIO
C3
00
WIR
E R
OP
E &
H
OO
KS
S
PE
CIF
IC
AT
IO
NS
ET
16
/1
8K
X
05
-0
9-1
6B
DA
TE
SE
CT
IO
N
SU
PE
RS
ED
ES
TIT
LE
10
-2
2-1
4A
232
27
LO
AD
B
LO
CK
A
SS
EM
BLY
WIR
E R
OP
E:
5/16" D
IA
, 80' LO
NG
GA
C 7X
19 X
IP
-R
HR
L-IW
RC
, S
B 9800 LB
S
WIR
E R
OP
E H
OO
K:
RA
TIN
G: 1.5 T
ON
NE
(3310 LB
S)
DIM
EN
SIO
NS
:
D
C
AA
A
D
C
B
LO
AD
B
LO
CK
H
OO
K:
RA
TIN
G: 3 T
ON
NE
(6615 LB
S)
DIM
EN
SIO
NS
:
AB
CD
1.13"
1.06"
5.50"
4.13"
CO
LO
RB
RA
ND
AA
CD
GO
LD
CR
OS
BY
2.00"
8.25"
6.50"
® VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
C200MAN. OVERRIDE INSTR.
ET NON-PROP CRANES
03-08-19ADATE SECTION
SUPERSEDES
TITLE
02-09-17 23084
MANUAL OVERRIDE INSTRUCTIONSET NON-PROPRTIONAL SERIES CRANES
! ! R E A D A L L I N S T R U C T I O N S B E F O R E P E R F O R M I N G M A N U A L O V E R R I D E P R O C E D U R E S ! !
Each valve station incorporates [2] hydraulic ports and [2] coils. Manualoverride shafts are located in the center of the coils (see figure 1).Manual override decals are placed on each crane near the valve assembly.These decals provide a visual aid that helps the operator determine the functiondesignations (Reference figure 2).
2-STATION FUNCTIONS:RR = Rot. Right RL = Rot. LeftBU = Boom Up BD = Boom Down
3-STATION FUNCTIONS include previous functions, plus:BI = Boom In BO = Boom Out
PORT
COIL
SHAFT
End Plate
UPOUT UP
RIGHT
DOWNIN DOWN
LEFT
EXTENSION WINCH
ELEVATION ROTATION
P O WE R
EM
E
RG E N C Y
S
TO
P
HORN
21990
ELEVATION
UPUP
RIGHT
DOWNDOWN
LEFT
WINCH
E
ROTATION
P O
C
W
E
R
Y
ME
RG
E N
HORN
S
TO
P
21991
RR
MANUAL OVERRIDE
BU 2
31
88
BO
ALWAYS BE SURE TO CHECK HYDRAULIC OIL LEVEL BEFORE PROCEEDING. IT IS RECOMMENDED TOREMOVE ANY ITEM(S) THAT MAY INTERFERE WITH OPERATING THE CRANE MANUALLY. IF POSSIBLE,
STRAPS AND/OR HARNESSES SHOULD BE REMOVED BEFORE OPERATING A CRANE IN MANUAL OVERRIDE !!
1
2
3Procedure:
1. Turn Master disconnect switch to "ON"
2. Power up the pendant / radio2.1. PENDANT - twist EMERGENCY STOP button clockwise2.2. RADIO - Press green ON button
3. On the crane, reference the function you wish to perform using the manual override decal
4. Using a tool with a diameter of 1/8" or smaller, press the shaft inward and hold
5. Reference the functions listed on your pendant or radio (see figure 3)
6. Press the switch or button for the same function
7. If you need to change function,7.1. Release switch or button7.2. Remove tool from shaft7.3. Go to step 3
For assistance, please feel free to contact Technical Support at 800-226-2238.
BATT ON
OFF / E STOP
RIGHT
OUT
HORN
UP
B O O M
UP
WINCH
IN
LEFT
ON
DOWN
DOWN
21986-ET
E T8 K REFER EN CE ET18KX REFERENCE ET25KX REFERENCE
C40
0R
EP
LAC
EM
EN
TP
AR
TS
DR
AW
ING
ET
16/1
8KX
10-2
2-14
A
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2179
608
-06-
10
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
1615
1211
7
10
518
8
917
3
2
1
1413
19
6
FO
RR
EP
LAC
EM
EN
TP
AR
TS
LIS
T,S
EE
2179
7F
OR
FA
ST
EN
ER
LIS
T,S
EE
2138
9
C40
0R
EP
LAC
EM
EN
TP
AR
TS
LIS
T
ET
16K
X/1
8KX
,(G
EN
.B,S
/N:9
5566
-C
UR
RE
NT
)
10-2
3-14
A
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2179
708
-06-
10
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
FO
RR
EP
LAC
EM
EN
TP
AR
TS
DR
AW
ING
,SE
E21
796
ET
16K
XS
TA
RT
ING
SE
RIA
LN
UM
BE
R:
1700
00E
T18
KX
ST
AR
TIN
GS
ER
IAL
NU
MB
ER
:95
566
SECTIONDATE
SUPERSEDES
TITLE
ET16/18KX
C40010-23-14A
02-15-07
RPLCMNT FSTENER LIST
21389
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
ET16/18KX REPLACEMENT FASTENER LIST
PART NUMBER
!HHCS03118063!LWSH-031-STAR!HHCS02520063!LWSH-025-STAR!HHCS06311200
!LWSH-063-STAR!HHCS06311300!LWSH-063-STAR!LWSH-038!HNUT-03816
!HHCS02520075!FNUT02520!HHCS03118075-F!HHCS02520075-F!HHCS02520050-F
!PHMS#0832063!LWSH-#08!PHMS#1024125!LWSH#10!HNUT-#1024
!HHCS02520063-F!SRNG-100!UNUT-02520!HHCS02520075!LWSH-025
!FWSH-025!HHCS02520075-F!HHCS02520050-F!HHCS03118075-F!SRNG-138
DESCRIPTION
HEX HEAD CAP SCREW; 5/16-18 X 5/8" LONGLOCK WASHER; 5/16", EXTERNAL STARHEX HEAD CAP SCREW; 1/4-20 X 5/8" LONGLOCK WASHER; 1/4", EXTERNAL STARHEX HEAD CAP SCREW; 5/8-11 X 2" LONG
LOCK WASHER; 5/8", EXTERNAL STARHEX HEAD CAP SCREW; 5/8-11 X 3" LONGLOCK WASHER; 5/8", EXTERNAL STARLOCK WASHER; 3/8", SPLITHEX NUT; 3/8-16
HEX HEAD CAP SCREW; 1/4-20 X 3/4" LONGFLANGE NUT; 1/4-20HEX HEAD CAP SCREW; 5/16-18 X 3/4", SELF TAPPINGHEX HEAD CAP SCREW; 1/4-20 X 3/4", SELF TAPPINGHEX HEAD CAP SCREW; 1/4-20 X 1/2", SELF TAPPING
PHILLIPS HEAD MACHINE SCREW; #8-32 X 5/8"LOCK WASHER; #8PHILLIPS HEAD MACHINE SCREW; #10-24 X 1 1/4"LOCK WASHER; #10HEX NUT; #10-24
HEX HEAD CAP SCREW; 1/4-20 X 5/8", SELF TAPPINGSNAP RING; 1"U-NUT; 1/4-20HEX HEAD CAP SCREW; 1/4-20 X 3/4" LONGLOCK WASHER; 1/4"
FLAT WASHER; 1/4"HEX HEAD CAP SCREW; 1/4-20 X 3/4", SELF TAPPINGHEX HEAD CAP SCREW; 1/4-20 X 1/2", SELF TAPPINGHEX HEAD CAP SCREW; 5/16-18 X 3/4", SELF TAPPINGSNAP RING; 1 3/8"
QTY
1133
16
16141444
44121
11221
12555
55131
LOCATION / FUNCTION
GROUND STRAP - CANDLESTICKGROUND STRAP - CANDLESTICKCANDLESTICK TO BASECANDLESTICK TO BASELOWER BASE TO RING
LOWER BASE TO RINGUPPER HOUSING TO RINGUPPER HOUSING TO RINGHYDRAULIC POWER UNITHYDRAULIC POWER UNIT
VALVE BLOCKVALVE BLOCKGROUND ON HOUSINGGROUND ON HOUSINGGROUND ON HOUSING
PENDANT PLUGPENDANT PLUGTOP POSITION SWITCHTOP POSITION SWITCHTOP POSITION SWITCH
CABLE CLAMP (PRESS. SWITCH)ELEVATION CYLINDER ROD PINLOWER COVERLOWER COVERLOWER COVER
LOWER COVERREAR COVERCORD REEL CABLE CLAMPSIDE COVERBOOM PIN (MAIN)
C40
021
200
BO
OM
PA
RT
SD
RA
WIN
G
ET
16/1
8KX
10-2
3-14
C
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2131
004
-21-
08B
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
7
1
21
32
4
5
6
8
9
10 11 12 13
1415
16
33
171819
20
21
22 23 24
25
2627
28
25
2829
30
3136
32
34
35
37 38
RE
FP
AR
TS
LIS
TD
RA
WIN
G21
322
2120
0B
OO
MP
AR
TS
DR
AW
ING
C40
021
200
BO
OM
PA
RT
SLI
ST
ET
16/1
8KX
10-2
3-14
B
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2132
212
-11-
13A
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
RE
FP
AR
TS
DR
AW
ING
2131
0
2120
0B
OO
MP
AR
TS
LIS
T
C4
00
ELE
CT
RIC
AL
CO
MP
ON
EN
TA
SS
EM
BLY
ET
16
/18K
X
12-1
4-1
8F
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
21397
02-1
0-1
5E
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLLC
CIN
CIN
NA
TI,
OH
IO
23
15
4-1
EL
EC
TR
ICA
LC
OM
PO
NE
NT
AS
SE
MB
LY
17600
MA
INC
ON
TA
CT
OR
19187-0
4T
ER
MIN
AL
BL
OC
K
204
99
-RW
INC
HU
P,
WIN
CH
DO
WN
,&
MA
INC
ON
TA
CT
OR
16011
VO
LT
AG
ES
TA
BIL
IZE
RA
SS
Y
15683
-20A
CIR
CU
ITB
RE
AK
ER
22739
WIN
CH
UP
,B
OO
MU
P&
DO
WN
,B
OO
MIN
&O
UT
&R
OT
AT
ION
INT
ER
LO
CK
159
59
CA
PA
CIT
OR
-W
IRIN
GD
IAG
RA
M
ET
16/1
8KX
W/H
OR
N
12-2
2-14
F
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2138
810
-27-
14E
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
01025-2*60INX
+-+ -
MF
RE
D
BLK
GR
N
CIR
CU
ITB
RE
AK
ER
GR
Y/D
IOD
EA
SS
Y.
+12
VW
HT
BLK
BLK
PU
R
(16)
BLU
+12
VD
C
WHT
WH
T
BLK B
LK
BLK
RR
BLK
BLK
YEL
WHT
RED
GRN
20357
BLK
22377
(2)
RE
D-R
L
(3)
GR
N-B
U
(1)
YE
L-W
U
(10)
RE
D/B
LK-R
R
BLK
(9)
YE
L/B
LK-W
D
(12)
OR
N/B
LK-B
I(4
)O
RN
-BO
FM
M F
MFM F
1601
1V
OLT
AG
ES
TA
BIL
IZE
RA
SS
Y
22254-RED060BC
2035
6
21270
21678
31.5"
(7)BLK
YE
L
SH
OR
TT
ER
MIN
AL
+-
#2#1
FM
2049
9-R
CO
NT
AC
TO
R
WIN
CH
YEL
D-
#2
U-
#1
27.5
"
YEL
BLU
/BLK
(GN
D)
2273
9R
elay
Win
chU
pB
oom
Up
&D
wn.
,B
oom
In&
Out
&R
otat
ion
Inte
rlock
NO
BLK
ELE
VA
TIO
NC
YLI
ND
ER
OV
ER
LOA
DP
RE
SS
UR
ES
WIT
CH
(N/C
)
1991
8B
OO
MT
OP
AN
GLE
SW
ITC
H(N
/O)
2158
4S
WIV
EL
TE
RM
AS
SY
BU
BO
RL
BD
BI
(11)
GR
N/B
LK-B
D
2603
5-2
5.5"
9.5"
Dio
de
2104
6
2280
7B
OO
MC
OR
DR
EE
L
1937
6A
NT
IT
WO
-B
LOC
KS
WIT
CH
(N/C
)
FM
MFWH
T
BLK
WH
T
WH
TB
LK
BLK
FM
MF
TO
12V
DC
+B
AT
TE
RY
TE
RM
INA
L
1345
1M
AS
TE
RD
ISC
ON
NE
CT
SW
ITC
H
HY
D.
PW
R.
UN
IT
1735
6O
PT
ION
AL
OV
ER
LOA
DA
LAR
M
22.5
"
1791
5T
ER
MIN
AL
BLO
CK
2081
2-1
2225
4-B
LK05
0CG
ET
16K
XS
TA
RT
ING
S/N
1700
00E
T18
KX
ST
AR
TIN
GS
/N95
900
16+
1S
OC
KE
T
01025-2*60INX
ET
16K
X=
P/N
1746
0-22
00-2
1E
T18
KX
=P
/N17
460-
2400
-21
CO
NT
RO
LV
ALV
E
1 2 3 4
9 10 11 12 135
146
157
168
SO
CK
ET
GN
D.
2248
0
NO
HO
RN
RE
LAY
+12
vR
ED
(15)
PU
R
BLK
(HO
RN
)
22254-BLK065CG
HO
RN
2194
8
(15)
PU
R(H
OR
N)
OP
ER
AT
OR
CO
NT
RO
LLE
D
BLK
(HO
RN
)
JUM
PE
R,
GN
D.W
IRE
2225
4-G
RN
060B
G
SECTIONDATE
SUPERSEDES
TITLE
ET16/18/25/30/36K(X)
C40002-21-17L
08-18-15K
16780 REPLACEMENT PARTS
19368
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
SWIVEL TERMINAL REPLACEMENT PARTSPLEASE REFER TO THE BILLS OF MATERIALS
FOR ADDITIONAL PART NUMBERS.
NOT ALL ILLUSTRATED PARTS ARE WITHINTHE KIT (16780-KIT).
THE 16780 SWIVEL TERMINAL CANREPLACE & INTERCHANGE WITH
THE 14231 SWIVEL TERMINAL, FORET20,000 & ET20K(X) CRANES.
11
2
3
4
5
6
7
9
10
12
15
16
17
18
1
13
14
8
1
23
4
F2
5
1
2TORQUE TO 15 FT-LBS
3
LOCTITE 242 BLUE& TORQUE TO 30 FT-LBSFOR QUILL APPLICATIONS
LOCTITE 242 BLUE
4STRETCH RUBBER WATER-SHED DISCP/N 27156 AROUND 'OUTSIDE' OF THEINVERTED FLARE NUT OFCANDLESTICK, AS SHOWN
5 ITEM #8, FIBER WASHER, 5/8 I.D.'MUST' SIT DIRECTLY ON TOP OF THEINVERTED FLARE NUT ITEM #6.
RE
PLA
CE
ME
NT
PA
RT
SD
RA
WIN
G&
LIS
TC
400
2206
0P
EN
DA
NT
(ST
AN
DA
RD
CO
NT
RO
L)
12-1
0-13
C
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2207
609
-28-
12B
®M
AN
UF
AC
TU
RIN
G,I
NC
.
CIN
CIN
NA
TI,
OH
IO
(IN
SID
EV
IEW
OF
PE
ND
AN
TC
ON
TR
OL
W/R
EA
RC
OV
ER
RE
MO
VE
D)
CO
RD
RE
PLA
CE
ME
NT
INS
TR
UC
TIO
NS
NO
TE
1)W
IRE
TE
RM
INA
LST
OB
EIN
ST
ALL
ED
'AF
TE
R'R
OU
TIN
GR
EP
LAC
EM
EN
TC
OR
DA
SS
YT
HR
OU
GH
PE
ND
AN
TH
EA
DA
ND
PLU
GH
OU
SIN
G.
NO
TE
2)T
OG
GLE
SW
ITC
HJU
MP
ER
WIR
ES
NO
TS
HO
WN
FO
RC
LAR
ITY
.
NO
TE
3)S
TO
WO
RC
UT
-BA
CK
UN
US
ED
WIR
ES
.
BLU
E-
BO
RE
D/B
LAC
K-
BI
1
23
3
DE
SC
RIP
TIO
NIT
EM
QT
YP
AR
TN
O.
BLA
CK
-H
YD
.PO
WE
RU
NIT
BLU
E/B
LAC
K-
BU
RE
D-
RL
YE
LLO
W-
WU
OR
AN
GE
-12
V+
BR
OW
N-
BD
BR
OW
N/R
ED
-R
RY
ELL
OW
/BLA
CK
-W
D
PLU
G-
BA
CK
SID
EV
IEW
RO
TA
TIO
NLE
FT
-R
ED
(2)
WIN
CH
UP
-Y
ELL
OW
(1)
WIN
CH
DO
WN
-Y
ELL
OW
/BLA
CK
(6)
12V
+-
OR
AN
GE
(10)
12V
+-
OR
AN
GE
(10)
BO
OM
UP
-B
LUE
/BLA
CK
(3)
HY
D.P
OW
ER
UN
IT-
BLA
CK
(5)
BO
OM
OU
T-
BLU
E(4
)
BO
OM
IN-
RE
D/B
LAC
K(9
)
SP
DT
MO
ME
NT
AR
YT
OG
GLE
SW
ITC
H1
122
081
21
1942
6P
LUG
CA
SE
-10
+1
PO
LEM
ALE
INS
ER
T-
10+
1P
OLE
31
1942
7
25F
EE
T,1
1C
ON
DU
CT
OR
BO
OM
DO
WN
-B
RO
WN
(8)
RO
TA
TIO
NR
IGH
T-
BR
OW
N/R
ED
(7)
DP
DT
MO
ME
NT
AR
YT
OG
GLE
SW
ITC
H4
322
152
4
2206
0P
EN
DA
NT
(4-
SW
ITC
H)
C40
0R
EPLA
CE
ME
NT
PAR
TS D
WG
& L
IST
2199
0 P
ND
NT;
4 F
NC
TN E
T C
RN
S, E
STP/
HR
N
01-1
2-17
BD
ATE
SE
CTI
ON
SU
PE
RS
ED
ES
TITL
E
2307
510
-20-
14A
®V
EN
CO
VE
NTU
RO
IND
UST
RIE
S LL
CC
INC
INN
ATI
, OH
IO
16-P
IN P
LUG
- B
ACKS
IDE
VIEW
161514131211109
87654321
UP
OU
TU
PR
IGH
T
DO
WN
IND
OW
NLE
FTE
XTEN
SIO
NR
OTA
TIO
NW
INC
HE
LEVA
TIO
N
BLU
E / B
LAC
K - R
RY
ELLO
W /
BLAC
K - W
D
RED
- 12
V+
BR
OW
N /
BLA
CK
- BD
OR
AN
GE
/ BLA
CK
- BI
BR
OW
N -
BU
YEL
LOW
- W
UB
LUE
- RL
OR
AN
GE
- BO
RED
/ B
LAC
K -
AU
X 1
2V+
BR
OW
N /
RE
D -
HY
D P
OW
ER U
NIT
CO
NTA
CTO
R
BLA
CK
- G
RO
UN
D
16-P
IN P
LUG
ASS
Y.
PO
WE
R
E M E
RG
EN
CY
S
TOP
HO
RN YEL
LOW
/ R
ED
- H
OR
N
2199
0 P
EN
DA
NT;
4 F
UN
CTI
ON
ET
CR
ANES
, E-S
TOP
/ HO
RN
NO
TE 1
:
WIR
E T
ER
MIN
ALS
TO
BE
INST
ALLE
D 'A
FTER
'
RO
UTI
NG
REP
LAC
EM
EN
T C
OR
D A
SSY
THR
OU
GH
PE
ND
AN
T H
EAD
AN
D P
LUG
HO
USI
NG
.
NO
TE 2
:
STO
W O
R C
UT
BAC
K U
NU
SED
WIR
ES.
8 7 6 5 4 3 2 1
ITEM
1 1 1 - 1 1 3 1
QTY
2215
6
2215
5
2213
5
-
2247
2
2247
1
2215
2
2208
1
PAR
T N
O.
SW
ITC
H; E
-STO
P
SW
ITC
H; P
US
HB
UTT
ON
, HO
RN
KIT
; RE
PLAC
EMEN
T C
OR
D A
SSY
- INS
ERT;
MAL
E, 1
6 +
1 PO
LE
PLU
G C
ASE
; 16
+ 1
POLE
SW
ITC
H; D
PD
T, M
OM
ENTA
RY
SW
ITC
H; S
PDT,
MO
MEN
TAR
Y
DES
CR
IPTI
ON
87 2
6
3 4
1
BO
OM
DO
WN
- B
RO
WN
/ B
LAC
K (
11)
BO
OM
UP
- B
RO
WN
(3)
BO
OM
IN -
OR
AN
GE
/ BLA
CK
(12)
BO
OM
OU
T - O
RAN
GE
(4)
WIN
CH
UP
- YE
LLO
W (
1)
WIN
CH
DO
WN
- YE
LLO
W /
BLA
CK
(9)
RO
TATI
ON
RT
- BLU
E / B
LAC
K (1
0)
RO
TATI
ON
LE
FT -
BLU
E (2
)
AU
X +
12V
- RE
D /
BLAC
K (8
)
(INSI
DE
VIE
W O
F P
END
AN
T C
ON
TRO
L W
/ RE
AR C
OV
ER R
EMO
VED
)
LEFT
RIG
HT
RO
TATI
ON
UP
DO
WN
EXT
ENSI
ON
UP
DO
WN
WIN
CH
ELE
VATI
ON
OU
T
IN
12
HO
RN
E-S
TOP
OU
TPU
T - Y
ELL
OW
/ R
ED (1
5)
+12V
- R
ED
(16)
FIG
. 1 -
TYPI
CA
L SW
ITC
H J
UM
PER
LA
YOU
T. C
ON
TAC
T PO
INTS
=
1 2 3
4 5 6
1 2 3
1 2 3
4 5 6
4 5 6
HYD
PO
WER
- B
RO
WN
/ R
ED (
7)
MO
DEL
ET8
KX
ET1
2KX
ET1
6KX
ET1
8KX
ET2
5KX
ET3
0KX
ET3
6KXX
STA
RTI
NG
S/N
7380
0
6980
0
1700
00
9590
0
1253
00
1303
00
1403
00
RO
TATI
ON
RIG
HT
RO
TATI
ON
LEF
TB
OO
M O
UT
BO
OM
INB
OO
M U
PB
OO
M D
OW
NP
RE
SSU
RE
RET
UR
N
RR
RL
BO
BI BU PR RE
BD
BI
BO
H4-
6400
-060
62
PLA
CES
2516
5
2516
6
H4-
6400
-060
68
PLA
CES 25
164
(BI)
2516
3 (B
D)
2516
8 (R
L)
2516
4 (B
O)
2516
3 (B
U)
2516
7 (R
R)
2516
5 (P
R)
2516
6 (R
E)S
EC
TIO
N V
IEW
A-A
A A
2516
4
2516
4
1924
7
2516
3 (B
U)
2516
3 (B
D)
RE
PR
2516
7 (R
R)
2516
8 (R
L)
H4-
6400
-061
0N
OTE
: LO
CAT
ED O
N O
PO
SIT
E
SID
E O
F M
OTO
R
C40
0H
YDR
AU
LIC
CO
MPO
NE
NTS
DR
AWIN
G
ET1
6/18
KX
12-1
6-16
BD
ATE
SE
CTI
ON
SU
PE
RS
ED
ES
TITL
E
2140
710
-23-
14A
®V
EN
CO
VE
NTU
RO
IND
UST
RIE
S LL
CC
INC
INN
ATI
, OH
IO
ET1
6/18
KX
HY
DR
AU
LIC
CO
MPO
NEN
TS D
RAW
ING
LEFT
SID
ER
IGH
T S
IDE
H68
05-0
404
MU
ST
US
E EL
BOW
FO
RP
RE
SSU
RE
SWIT
CH
IN
P
C
P
CIN
SV
2S
V1
SV
3
OP
ER
AT
ION
RO
TA
TIO
NM
OT
OR
MO
ME
NT
OV
ER
LOA
DP
RE
SS
UR
ES
WIT
CH
EX
TE
NS
ION
CY
LIN
DE
R
ELE
VA
TIO
NC
YLI
ND
ER
BD
BU
V4
BO
BI
V4
RL
RR
S2 S2 S1 S2 S1
SV1 SV3SV2
"P"
"T"
S
M
PA B C D E F
T
S1
CH
EM
AT
IC
ER
NE
RG
IZE
"S2"
OP
EN
FLO
W'P
'TO
'A'
'B'T
O'T
'E
NE
RG
IZE
"S1"
OP
EN
FLO
W'P
'TO
'B'
'A'T
O'T
'
EN
ER
GIZ
E"S
2"O
PE
NF
LOW
'P'T
O'C
''D
'TO
'T'
EN
ER
GIZ
E"S
1"O
PE
NF
LOW
'P'T
O'D
''C
'TO
'T'
EN
ER
GIZ
E"S
2"O
PE
NF
LOW
'P'T
O'E
''F
'TO
'T'
EN
ER
GIZ
E"S
1"O
PE
NF
LOW
'P'T
O'F
''E
'TO
'T'
C40
0H
YD
RA
ULI
CS
YS
TE
MD
IAG
RA
M
ET
16/1
8/25
/30/
36K
X
10-2
3-14
D
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2015
601
-31-
05C
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
ET
16/1
8/25
/30/
36K
XH
YD
RA
ULI
CC
OM
PO
NE
NT
DIA
GR
AM
2177
8M
OT
OR
!HN
UT
-044
14H
EX
NU
T(W
IRE
RO
PE
AN
CH
OR
)O
RE
QU
IVA
LEN
TM
ET
RIC
HE
XN
UT
2198
0B
RA
KE
AS
SY
C40
0W
INC
H(D
C25
00)
RE
PLA
CE
ME
NT
PA
RT
S
ET
16/1
8KX
10-2
3-14
F
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2105
405
-01-
13E
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
2121
5W
INC
H(D
C25
00)
RE
PLA
CE
ME
NT
PA
RT
S
2112
3M
OT
OR
(ON
LY)
2121
8-
MO
TO
RS
EA
LK
IT
2173
5S
LEW
ING
SY
ST
EM
RE
PLA
CE
ME
NT
PA
RT
S
C40
0S
LEW
ING
SY
ST
EM
RE
PLA
CE
ME
NT
PA
RT
S
ET
8/12
K&
ET
8/12
/16/
18K
X
10-2
3-14
B
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2197
312
-27-
13A
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
2250
2325
2600
3175
4500
4500
1500
1550
1725
2100
3000
4500
43252250
1575
1300
1150
11250°
75° 60°
45°
30°
15°
16
FT.
12
FT.
8F
T.I F T I NG
L
C APACI TY
LN
BS
.
I
ET/
HT
18K
(X)
8-1
2-16
FT.
BO
OM
BOOM
AN
GL
E
NO
TEU
SE
LO
AD
BL
OC
KF
OR
LO
AD
SO
VE
R22
50LB
S.
BO
OM
LE
NG
TH
C40
0D
EC
AL
PLA
CE
ME
NT
ET
16/1
8KX
05-0
7-15
B
DA
TE
SE
CT
ION
SU
PE
RS
ED
ES
TIT
LE
2139
308
-07-
15A
®V
EN
CO
VE
NT
UR
OIN
DU
ST
RIE
SLL
C
CIN
CIN
NA
TI,
OH
IO
BO
OM
TH
ISM
AC
HIN
EIS
NO
TIN
SU
LA
TED
EL
EC
TR
OC
UT
ION
HA
ZAR
D
DA
NG
ER
! !C
AU
TIO
N
DA
NG
ER
!T
HIS
CR
AN
EIS
NO
TA
PA
SS
EN
GE
RL
IFT
YO
UM
US
TN
OT
OP
ER
ATE
TH
ISC
RA
NE
UN
LES
S:
UN
PLU
GR
EM
OT
EC
ON
TR
OL
PE
ND
AN
TW
HE
N
NO
TIN
US
E
GR
EA
SE
ER
EQ
UIP
ME
NT
TA
GE
LIN
ES
ES
S.
OLT
S,
RE
FE
RE
NC
EO
SH
A19
26.1
408,
GE
EL
EC
TRIC
AL
SA
FE
TY
OR
DE
RS
.1
54
01
-D
MANUAL OVERRIDER
R
BU
BO 2
31
88
DA
NG
ER
!U
NL
AW
FU
LT
OO
PE
RA
TE
TH
ISE
QU
IPM
EN
TW
ITH
IN2
0F
EE
TO
FH
IGH
-VO
LTA
GE
LIN
ES
OF
350,
000
VO
LTS
OR
LES
S.
FO
RM
INIM
UM
CLE
AR
AN
CE
SO
FH
IGH
-VO
LTA
GE
LIN
ES
INE
XC
ES
SO
F3
50,0
00V
OL
TS,
RE
FER
EN
CE
OS
HA
192
6.14
08,
CR
AN
E'S
SA
FE
TY
MA
NU
AL
,A
ND
CA
L-O
SH
AA
RT
ICL
E3
7,
TIT
LE
8,H
IGH
-VO
LTA
GE
ELE
CTR
ICA
LS
AFE
TYO
RD
ER
S.
15
40
1-D
13397-E
Ret
ract
All
Cyl
inde
rsP
rior
toS
ervi
cing
AW
46
or
DE
XR
ON
IIIA
TF
OIL
LEV
EL G
RE
AS
E
GREASE
GREASE
MANUAL OVERRIDE
RL
BD
BI 2
31
91
31
4"F
RO
MT
OP
TO
OIL
LEV
EL
LE
FT
BA
CK
RIG
HT
GR
EA
SE
(3)
1447
3-2M
AN
UA
LO
VE
RR
IDE
2319
1
OIL
LEV
EL
1339
7
DA
NG
ER
:U
NLA
WF
UL
TO
OP
ER
AT
E15
401
GR
EA
SE
(3)
1447
3-2
MA
NU
AL
OV
ER
RID
E23
188
DA
NG
ER
:E
LEC
.H
AZ
AR
D15
392
DA
NG
ER
:N
OT
PA
SS
EN
GE
RLI
FT
1539
2U
NP
LUG
PE
ND
AN
T15
398
CA
UT
ION
1539
0
SECTIONDATE
SUPERSEDES
TITLE
ET16/18KX
C40005-06-15D
04-22-13C
FIELD SERVICE LABEL KIT
20818
®VENCO VENTURO INDUSTRIES LLC
CINCINNATI, OHIO
PART NO. QTY. DESCRIPTION14473-2 6 DECAL; GREASE17389 2 DECAL; VENTURO LOGO, MEDIUM
21190-1 1 DECAL; BOOM CAPACITY, RIGHT, ET18KX
21190-2 1 DECAL; BOOM CAPACITY, LEFT, ET18KX
21192 2 DECAL; MODEL NAME
13397 1 DECAL; OIL LEVEL23188 1 DECAL; MANUAL OVERRIDE, RIGHT
23191 1 DECAL; MANUAL OVERRIDE, LEFT
17813 1 DECAL; OVERLOAD SENSING SYSTEM
20818 1 IDWG; FIELD SERVICE LABEL KIT
21393 1 IDWG; DECAL PLACEMENTINST-23233 1 SAFETY MANUAL, VENTURO CRANES
15397 1 KIT; ACCIDENT PREVENTION SIGNS
PART NO. QTY. DESCRIPTION15390 1 DECAL; CAUTION, OPERATIONS15391 1 DECAL; DANGER, NOT PASSENGER LIFT15392 1 DECAL; DANGER, ELECTRICAL HAZARD SIGN15393 4 DECAL; DANGER, ELECTRICAL HAZARD15394 1 APPLICATION INSTRUCTIONS15398 1 DECAL; UNPLUG PENDANT15401 1 DECAL; UNLAWFUL TO OPERATE15513 1 DECAL; MASTER DISCONNECT22317 1 DECAL SHEET; VENTURO, COMPLEMENTARY20927 1 DECAL; CRANE STABILITY
15397 ACCIDENT PREVENTION SIGNS
PART NO. QTY. DESCRIPTION14473-2 6 DECAL; GREASE
17389 2 DECAL; VENTURO LOGO, MEDIUM24018-1 1 DECAL; BOOM CAPACITY, RIGHT, ET16KX
24018-2 1 DECAL; BOOM CAPACITY, LEFT, ET16KX
24019 2 DECAL; MODEL NAME, ET16KX
13397 1 DECAL; OIL LEVEL
23188 1 DECAL; MANUAL OVERRIDE, RIGHT
23191 1 DECAL; MANUAL OVERRIDE, LEFT
17813 1 DECAL; OVERLOAD SENSING SYSTEM20818 1 IDWG; FIELD SERVICE LABEL KIT
21393 1 IDWG; DECAL PLACEMENT
INST-23233 1 SAFETY MANUAL, VENTURO CRANES
15397 1 KIT; ACCIDENT PREVENTION SIGNS
ET16/18KX FIELD SERVICE LABEL KITS
NOTE:APPLICABLE SERIAL NUMBERS: 95566 - CURRENT
NOTE:APPLICABLE SERIAL NUMBERS: 170000 - CURRENT
24021; FIELD SERVICE LABEL KIT, ET16KX
21108; FIELD SERVICE LABEL KIT, ET18KX
Revised: January 2015 12-00073_VNT1-D
VENTURO CRANES LIMITED WARRANTY POLICY Venturo products are built to last…we guarantee them. As a purchaser of any new Venturo product covered by warranty, you will receive 1 year of the most complete coverage available…and, at no added cost to you.
1-Year Limited Warranty Policy
This limited policy warrants new products of Venturo to be free from defects in material and workmanship for a period
of one (1) year from date of original installation. OEM products or accessories purchased by Venturo as part of or
offered with our product will carry the OEM manufacturer’s respective warranty. Our warranty covers:
Repair or replacement of product
Labor to repair or replace product
Freight to return and/or replace product
We shall not be liable for any contingent liabilities arising out of the improper function of any products. Warranty shall
become void if the product is improperly installed, modified, damaged, abused or used for application other than
intended use. There is no warranty of merchantability, fitness for a particular purpose, warranty arising from course of
dealing or usage of trade, or any other implied or expressed warranty, except as made specifically herein. This warranty
supersedes all previous warranties, written or implied.
Warranty Claims
Venco Venturo Industries LLC will make a good faith effort for prompt correction or other adjustment with respect to any product, which proves to be defective after our inspection and within the warranty period. Before any repairs are attempted or before returning any product, your Venturo Distributor is required to obtain a warranty claim number. This number is necessary for any claim to be considered. To obtain a warranty claim number, Venturo requires the model and serial number. Only authorized Venturo Distributors can perform warranty. For the name and address of your local Venturo Distributor call the Warranty Claim Department - 513-772-8448. WARNING - It is the responsibility of the installer to ensure the installation is completed according to the manufacturer's recommendations, ensure the ultimate user understands how to operate product in a safe manner, and understands the need for regular service and maintenance by an authorized Venturo Distributor. No modifications or alterations may be made to any Venturo product without the expressed written consent of Venco Venturo Industries LLC. Installation of any Venturo product must be done by an authorized Venturo Distributor, to the standards of the industry; including maintenance, service and affixing of all instruction, safety and warning decals. Users should be instructed as to the safe operation at time of delivery. Maintenance, service, operation and safety warning decals are available on request from Venco Venturo Industries LLC.
VENCO VENTURO INDUSTRIES LLC 12110 BEST PLACE | CINCINNATI, OHIO 45241
P: 800-226-2238 | F: 513-326-5427 www.venturo.com