23
Copyright © 2011 Idondivi, Inc. All rights reserved. Categories ; Posterior, Flapless, Astra Tech

Implant case

Embed Size (px)

DESCRIPTION

This is a straight forward situation. Implant placement in healed site 3 months after extraction of a hopeless tooth. Since the guided instrumentation of Astra Tech is not compatible with the diameters of the 3D Click Guide, the universal drill guides from Idondivi, Inc. are used to prepare an osteotomy per the Astra Tech drilling protocol. A standard implant carrier is used for visual guided implant placement.

Citation preview

Page 1: Implant case

Copyright © 2011 Idondivi, Inc. All rights reserved.

Categories ; Posterior, Flapless, Astra Tech

Page 2: Implant case

2 Copyright © 2011 Idondivi, Inc. All rights reserved

Non restorable lower first molar, extracted, healed site at 3 Months

Page 3: Implant case

3 Copyright © 2011 Idondivi, Inc. All rights reserved

Healed site # 19

Page 4: Implant case

4 Copyright © 2011 Idondivi, Inc. All rights reserved

Purposely over extended impression captures 14 mm of the alveolar ridge

Page 5: Implant case

5 Copyright © 2011 Idondivi, Inc. All rights reserved

Bone sounding measurements topical anesthetic and small needle with rubber-

stop.

Page 6: Implant case

6 Copyright © 2011 Idondivi, Inc. All rights reserved

Denture tooth, the “fastest wax –up in the west”, and reusable over and over

again.

Page 7: Implant case

7 Copyright © 2011 Idondivi, Inc. All rights reserved

Vacuform of denture tooth

Page 8: Implant case

8 Copyright © 2011 Idondivi, Inc. All rights reserved

BLP related to screw access hole in the central fossa.

Page 9: Implant case

9 Copyright © 2011 Idondivi, Inc. All rights reserved

Wings attached to vacuform carrier. Note that position of BLP is just a starting

point, the wings are positioned independently, while the BLP is locking in the

Bucco-Lingual and the platform position of the implant.

Page 10: Implant case

10 Copyright © 2011 Idondivi, Inc. All rights reserved

Radiograph is diagnostic since the RIR’s overlap. The trajectory needs correction

though.

Page 11: Implant case

11 Copyright © 2011 Idondivi, Inc. All rights reserved

A 7 degree ( red) rotation block is selected. A metal drill guide is placed, and the

trajectory is verified.

Page 12: Implant case

12 Copyright © 2011 Idondivi, Inc. All rights reserved

Adequate attached tissue allows tissue punch.

Page 13: Implant case

13 Copyright © 2011 Idondivi, Inc. All rights reserved

Nobel Biocare starting drill is used ( not to full depth) , although an Astra Tech

implant will be placed. The starting drill removes the tissue plug, and flattens the

ridge.

Page 14: Implant case

14 Copyright © 2011 Idondivi, Inc. All rights reserved

Facilitate 2.0 drill with build in stop. Tip to stop 18.7 mm , listed as 18 mm.

Page 15: Implant case

15 Copyright © 2011 Idondivi, Inc. All rights reserved

Osteotomy preparation for 8 mm implant

Page 16: Implant case

16 Copyright © 2011 Idondivi, Inc. All rights reserved

Verification of initial twist drill preparation

Page 17: Implant case

17 Copyright © 2011 Idondivi, Inc. All rights reserved

3.2 mm Facilitate drill

Page 18: Implant case

18 Copyright © 2011 Idondivi, Inc. All rights reserved

3.7 Facilitate drill per Astra Tech drilling protocol.

Page 19: Implant case

19 Copyright © 2011 Idondivi, Inc. All rights reserved

Astra Tech OsseoSpeed TX 4.0 S - 8 mm

Page 20: Implant case

20 Copyright © 2011 Idondivi, Inc. All rights reserved

Visual guidance of implant placement. The guided carrier from Astra does not fit

the hole diameter of the 3DCG. Hence the use of the regular Astra implant carrier

Page 21: Implant case

21 Copyright © 2011 Idondivi, Inc. All rights reserved

Implant placed to full depth. Bottom of osteotomy is the depth control.

Page 22: Implant case

22 Copyright © 2011 Idondivi, Inc. All rights reserved

Implant placed as planned

Page 23: Implant case

23 Copyright © 2011 Idondivi, Inc. All rights reserved

Implant placed as planned