Categories ; Posterior, Flapless, Astra Tech
2 Copyright © 2011 Idondivi, Inc. All rights reserved
Non restorable lower first molar, extracted, healed site at 3 Months
3 Copyright © 2011 Idondivi, Inc. All rights reserved
Healed site # 19
4 Copyright © 2011 Idondivi, Inc. All rights reserved
Purposely over extended impression captures 14 mm of the alveolar ridge
5 Copyright © 2011 Idondivi, Inc. All rights reserved
Bone sounding measurements topical anesthetic and small needle with rubber-
stop.
6 Copyright © 2011 Idondivi, Inc. All rights reserved
Denture tooth, the “fastest wax –up in the west”, and reusable over and over
again.
7 Copyright © 2011 Idondivi, Inc. All rights reserved
Vacuform of denture tooth
8 Copyright © 2011 Idondivi, Inc. All rights reserved
BLP related to screw access hole in the central fossa.
9 Copyright © 2011 Idondivi, Inc. All rights reserved
Wings attached to vacuform carrier. Note that position of BLP is just a starting
point, the wings are positioned independently, while the BLP is locking in the
Bucco-Lingual and the platform position of the implant.
10 Copyright © 2011 Idondivi, Inc. All rights reserved
Radiograph is diagnostic since the RIR’s overlap. The trajectory needs correction
though.
11 Copyright © 2011 Idondivi, Inc. All rights reserved
A 7 degree ( red) rotation block is selected. A metal drill guide is placed, and the
trajectory is verified.
12 Copyright © 2011 Idondivi, Inc. All rights reserved
Adequate attached tissue allows tissue punch.
13 Copyright © 2011 Idondivi, Inc. All rights reserved
Nobel Biocare starting drill is used ( not to full depth) , although an Astra Tech
implant will be placed. The starting drill removes the tissue plug, and flattens the
ridge.
14 Copyright © 2011 Idondivi, Inc. All rights reserved
Facilitate 2.0 drill with build in stop. Tip to stop 18.7 mm , listed as 18 mm.
15 Copyright © 2011 Idondivi, Inc. All rights reserved
Osteotomy preparation for 8 mm implant
16 Copyright © 2011 Idondivi, Inc. All rights reserved
Verification of initial twist drill preparation
17 Copyright © 2011 Idondivi, Inc. All rights reserved
3.2 mm Facilitate drill
18 Copyright © 2011 Idondivi, Inc. All rights reserved
3.7 Facilitate drill per Astra Tech drilling protocol.
19 Copyright © 2011 Idondivi, Inc. All rights reserved
Astra Tech OsseoSpeed TX 4.0 S - 8 mm
20 Copyright © 2011 Idondivi, Inc. All rights reserved
Visual guidance of implant placement. The guided carrier from Astra does not fit
the hole diameter of the 3DCG. Hence the use of the regular Astra implant carrier
21 Copyright © 2011 Idondivi, Inc. All rights reserved
Implant placed to full depth. Bottom of osteotomy is the depth control.
22 Copyright © 2011 Idondivi, Inc. All rights reserved
Implant placed as planned
23 Copyright © 2011 Idondivi, Inc. All rights reserved
Implant placed as planned