Test results reported for: Customer Reference P/N: 701946-6WXLP2 Device Model: Orb Optronix report: Original issue date: Prepared for: Testing performed by: SloanLED CSA GROUP 5725 Olivas Park Drive 1003 7th Ave. Ventura, CA 93003 Kirkland, WA 98033 425-605-8500 Attn: Aaron Meyer www.OrbOptronix.com [email protected] 805.676.3200 ext. 135 Test report prepared by: Test report approved by: Marius Timbus Test Technician, Test and Measurement Services Aaron Miller Laboratory Manager, Test and Measurement Services IES LM79-08 Sphere and Goniometer Test Report SLOD002-070 - 18 May 2015 This report may not be reproduced except in full without permission of CSA Group Page 1 of 13 CSA Group 1003 7th Ave., Kirkland, WA 98033 425-605-8500 www.OrbOptronix .com

IES LM79-08 Sphere and Goniometer Test Report

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: IES LM79-08 Sphere and Goniometer Test Report

Test results reported for:Customer Reference P/N: 701946-6WXLP2

Device Model:

Orb Optronix report:

Original issue date:

Prepared for: Testing performed by:SloanLED CSA GROUP5725 Olivas Park Drive 1003 7th Ave.Ventura, CA 93003 Kirkland, WA 98033

425-605-8500Attn: Aaron Meyer www.OrbOptronix.com

[email protected] ext. 135

Test report prepared by: Test report approved by:

Marius Timbus

Test Technician,

Test and Measurement Services

Aaron Miller

Laboratory Manager,

Test and Measurement Services

IES LM79-08 Sphere and Goniometer Test Report

SLOD002-070

-

18 May 2015

This report may not be reproduced except

in full without permission of CSA GroupPage 1 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 2: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

Customer Part Number: 701946-6WXLP2

Frequency (Hz):

1.0 Description of test sample

Manufacturer SpecificationsManufacturer: Sloan LED

Voltage (VDC): 12

SLOD002-07Orb Test Sample Number:

Sample mounted for measurements :

in S40 Sphere on the Goniometer

DCManufacturer Part Number:

Description:

This report may not be reproduced except

in full without permission of CSA Group.Page 2 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 3: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

2.2 Integrating sphere and goniometer geometries

Illustration of sphere measurement geometry. Optical

measurements are made via a spectroradiometer

located on a satellite sphere at the equator. An

absorption correction measurement is applied to each

measurement.

2.0 Scope of testing

Photometric and electrical testing in accordance with IES LM 79-08 IES Approved Method for the Electrical and Photometric

Measurements of Solid-State Lighting Products. Measuremets are made using the sphere -spectroradiometric test method and the

goniometer - spectroradiometer test method.

2.1 Test protocol and data reduction

1. Sphere-spectroradiometer measurements are reported for all values except luminous intensity distribution and results derived from

luminous intensity distribution measurments.

2. Sphere measurements are made in a 40'' integrating sphere with geometry as shown below. Absorption correction measurements

are applied to all sphere measurements.

3. Luminous intensity distribution measurements are made with a a type C goniometer coordinate system (reference IESNA LM-75) in

the geometry shown below.

4. Data is reported for the 380nm to 780nm spectral range with a 1 nm resolution.

5. Test samples are allowed to reach electrical and photometric stabilization per LM-79 requirements prior to measurement.

Illustration of goniometer measurement geometry and coordinate

system. Sample is rotated through F lateral angles and through q

vertical angles.

This report may not be reproduced except

in full without permission of CSA Group.Page 3 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 4: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

Test Conditions

Test Date: Stabilization time (min):

sphere - spectroradiometer Total operating test time of sample (min):

Sphere geometry: Operating time prior to measurement (min):

Sample orientation:

Correction factors applied:

Optical Measurements

Total Integrated Luminous Flux (lm): Chromaticity Coordinates

Luminous Efficacy (lm/W): Cx:

Correlated Color Temperature - CCT (K): Cy:

Color Rendering Index - CRI, Ra: u:

R9: v: Color Purity (%): u':

Dominant Wavelength (nm): v':

Total Integrated Radiometric Flux (W): Duv:

Peak Wavelength (nm):

Electrical Measurements

Input Power(W): Input Voltage(VDC): * Set point

Input Current (A):

Power Factor: Frequency (Hz): * Set point

Thermal Measurements

Ambient Temperature (°C):

Ambient Humidity (%RH):

Sample Temperature (°C):

base down

3.0 Results - Sphere Measurements

12-May-15

Method:

4p

36

80

9

self absorption correction

172.14

96.19 0.3172

6245 0.3322

73 0.1998

-20 0.3138

- 0.1998

490.8 0.4707

0.54 0.0000

453.0

25.1

24.0

34.4

1.79 11.92

0.150

- 0.00

This report may not be reproduced except

in full without permission of CSA Group.Page 4 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 5: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

3.1 Charts - Sphere Measurements - Luminous Flux, Radiant Flux

0.0E+00

1.0E-03

2.0E-03

3.0E-03

4.0E-03

5.0E-03

6.0E-03

380 430 480 530 580 630 680 730 780 830

Spe

ctra

l Rad

ian

t Fl

ux

(W/n

m)

Wavelength (nm)

Spectral Radiant Flux

0.0E+00

5.0E-01

1.0E+00

1.5E+00

2.0E+00

2.5E+00

380 430 480 530 580 630 680 730 780

Spe

ctra

l Lu

min

ou

s Fl

ux

(lm

/nm

)

Wavelength (nm)

Spectral Luminous Flux

This report may not be reproduced except

in full without permission of CSA Group.Page 5 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 6: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

3.2 Charts - Sphere Measurements - Spectral Power Distribution

Wavelength

(nm)(W/nm)

Wavelength

(nm)(W/nm)

Wavelength

(nm)(W/nm)

6.10E-04

380 2.75E-05 520 2.26E-03 660 7.89E-04

390 3.48E-05 530 2.70E-03 670

3.93E-04

400 4.54E-05 540 2.87E-03 680 4.95E-04

410 8.02E-05 550 2.92E-03 690

2.26E-04

420 3.31E-04 560 2.87E-03 700 3.08E-04

430 1.08E-03 570 2.82E-03 710

1.32E-04

440 2.74E-03 580 2.70E-03 720 1.81E-04

450 5.37E-03 590 2.52E-03 730

8.81E-05

460 3.84E-03 600 2.26E-03 740 1.07E-04

470 1.70E-03 610 1.96E-03 750

4.91E-05

480 7.96E-04 620 1.70E-03 760 8.51E-05

490 6.04E-04 630 1.44E-03 770

500 9.03E-04 640 1.18E-03 780 4.30E-05

510 1.59E-03 650 9.77E-04

3.3 Charts - Sphere Measurements - CIE 1931 Chromaticity

CIE1931 Chromaticity Diagram

Plankian

Average

This report may not be reproduced except

in full without permission of CSA Group.Page 6 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 7: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

3.4 Charts - Sphere Stabilization

172

172

173

173

174

174

175

175

176

176-8

0

-70

-60

-50

-40

-30

-20

-10 0

Lum

ino

us

Flu

x (l

m)

time (minutes)

Luminous Flux Stabilization (measurement is reported at time t=0)

Luminous Flux

(-)0.25% t=0 value

0.25% t=0 value

1.784

1.785

1.786

1.787

1.788

1.789

1.79

1.791

1.792

1.793

1.794

1.795

-80

-70

-60

-50

-40

-30

-20

-10 0

Po

we

r (W

)

time (minutes)

Electrical Stabilization (measurement is reported at time t=0)

Model

(-)0.25% t=0 value

0.25% t=0 value

This report may not be reproduced except

in full without permission of CSA Group.Page 7 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 8: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

Test Conditions

Test Date: Phi Minimum: ± 0.10°

gonio-spectroradiometer Phi Maximum: ± 0.10°

x-axis Alignment: Phi Step Size: ± 0.10°

y-axis Alignment: Theta Minimum: ± 0.10°

z-axis Alignment: Theta Maximum: ± 0.10°

Theta Step Size: ± 0.10°

Optical Measurements*

Beam Lumens(lm):

Beam Angle(: Beam Efficiency (%):

Field Angle (): Field Lumens (lm):

On-axis Intensity (cd): Field Efficiecncy (%):

Maximum Intensity (cd): Total Lumens (lm):

*Intensity and irradiance charts are given in the following sections

Electrical Measurements

Input Power(W): Input Voltage(VAC): * Set point

Input Current (A):

Power Factor: Frequency (Hz): * Set point

Ambient Temperature (°C):

Ambient Humidity (%RH):

Sample Temperature (°C):

60.7

4.0 Results - Goniometric Measurements

13-May-15 0.0

Method: 360.0

0.0 ± 0.001 m 22.5

0.0 ± 0.001 m 0.0

0.5 ± 0.001 m 115.0

2.5

28.7 37.10%

57.7 116.3

436.181 71.10%

436.181 163.5

1.79 11.93

0.15

- DC

24.8

24.0

32.3

This report may not be reproduced except

in full without permission of CSA Group.Page 8 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 9: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

4.1 Charts - Goniometric Measurement - Candela Plots

This report may not be reproduced except

in full without permission of CSA Group.Page 9 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 10: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

Lumens Per Zone

Zone Lumens  % Total

  90-100 0.6 0.3%

  100-110 0.5 0.3%

0.0%

  150-160 0 0.0%

  160-170 0 0.0%

  170-180 0 0.0%

  140-150 0

  110-120 0.2 0.1%

  120-130 0 0.0%

  130-140 0 0.0%

Beam (50%): 37.10% 60.7 34.4 23

Total: 100.00% 163.5

4.2 Goniometric Measurement - Zonal Lumen and Beam Spread Summary

Efficiency LumensHorizontal

Spread

Vertical

Spread

Field (10%): 71.10% 116.3 70.1 45.3

0-30 118.5 72.50% 0-10 34.7 21.2%

Zonal Lumen Summary Lumens Per Zone

Zone Lumens % Lamp Zone Lumens  % Total

0-60 152.8 93.50% 20-30 31 18.9%

0-40 135.3 82.80% 10-20 52.8 32.3%

163.5 100.00%

70-100 4.9 3.00% 40-50 10.4 6.3%

60-90 9.4 5.80% 30-40 16.8 10.3%

90-120 1.2 0.80%

70-80 3.1 1.9%

80-90 1.3 0.8%

50-60 7.1 4.4%

60-70 5 3.1%0-90 162.2 99.20%

90-180 1.2 0.80%

0-180

This report may not be reproduced except

in full without permission of CSA Group.Page 10 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 11: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

4.3 Goniometric Measurement - Illuminance Plots

4.4 Goniometric Measurement - Coefficients of Utilization

This report may not be reproduced except

in full without permission of CSA Group.Page 11 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 12: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

Sphere lamp standard

Sphere test instrumentation

Goniometer lamp standard

Goniometer test instrumentation

5.0 Equipment

Lamp standard type

Operating

voltage (VDC)

Operating current

(A) Watts (W)

Lumen output

(lm) Calibration date

Name of calibration

lab

Labsphere primary lumen standard1 s/n A51 NIST 844/273735-06 July 7, 2006

Labsphere working standards of spectral

radiant flux. NOTE: only three working

lamps re used in a 3rd generation

calibration.

Labsphere

Sphere lamp calibration chain: Luminous flux measurements are traceable to NIST through a 3rd generation lamp of known flux

maintained at Orb Optronix. The calibration chain is given below.

Generation Standard Report/File Number Calibration Date Description

Tungsten Halogen 12.8 2.600 A 35 540.6 3/28/2013

OCL-WL2 SCL-1400-WL2 July 24, 2008

OCL-WL3 SCL-1400-WL3 July 24, 2008

OCL-WL6 SCL-1400-WL6 July 24, 2008

OCL-WL4 SCL-1400-WL4 July 24, 2008

OCL-WL5 SCL-1400-WL5 July 24, 2008

2

OCL-WL1 SCL-1400-WL1 July 24, 2008

Integrating sphere 40 '' diameter Labsphere CA-10281-000 1230105283 at use

Orb Optronix primary standard

Item Description /use Manufacturer Model Serial# Calibration due

3 A102 SCL-600-A102 March, 7, 2012

Power Supply Electrical Supply Kikusui PCR500M RB002843 -

Spectrometer optical measurements Orb Optronix SP-75 2010268 at use

Digital Power Meter Electrical Measurements Yokogawa WT210 91L137852 17-Apr-16

SourceMeter Cal lamp current source Keithley 2425 1186074 12-Nov-15

Goniometer lamp calibration chain: Irradiance measurements are traceable to NIST through a 2nd generation lamp of known

irradiance maintained at Orb Optronix. The calibration chain is given below.

Generation Standard Report/File Number Calibration Date Description

Calibration reference

Tungsten Halogen 115 8.00 1000 8364.0 04/05/2011 0006389-01

Lamp standard type

Operating

voltage (VDC)

Operating current

(A) Watts (W) Illuminance (lux) Calibration date

1 s/n F‐626 NIST# 844/278192‐09 1/3/2011 NIST 1000W standard lamp

Item Description /use Manufacturer Model Serial#

Spectroradiometer Optical measurements Orb Optronix SP-200 2009063 8-Apr-16

Calibration due

2‐Axis Type C Goniometer - Orb Optronix CA-10281-000 - at use

Digital Power Meter Electrical Measurements Yokogawa WT210 91L122464 29-Apr-16

Power Supply Electrical Supply Kikusui PCR500M RB002844 -

This report may not be reproduced except

in full without permission of CSA Group.Page 12 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com

Page 13: IES LM79-08 Sphere and Goniometer Test Report

IES LM79-08 Sphere and Goniometer Test Report

Orb Optronix Report: SLOD002-070

Issue Date: 150518

Part Number: 701946-6WXLP2

6.0 Additional information1. This report may not be used to claim product certification, approval or endorsement by NVLAP, NIST, or any agency of the Federal

Government.

END OF REPORT

This report may not be reproduced except

in full without permission of CSA Group.Page 13 of 13

CSA Group1003 7th Ave., Kirkland, WA 98033

425-605-8500

www.OrbOptronix .com