The new Current initiative 16 June 2021 IEC 61439 1 & 2 IEC 61439, the one standard for all switchgear and control gear assemblies is applicable to all power distributors, meter boxes and distribution enclosures for private and commercial buildings, assemblies for construction sites and power distribution. Certification of distribution assemblies is defined by international standard IEC 61439. This standard provides common rules that are recognised worldwide. Compliance with the standard is certified, depending on the country or market, by a declaration of the panel builder, the design oce, the installer or the user. Just to mention before going into test, that low voltage switchgear and control gear assemblies (Un 1000 V AC) may be used at the origin of an electrical installation with: 1. Low Voltage Main switchboard (transformer area) 2. Low Voltage Main Distribution Board (technical area) Prisan REFERENCE - BCH TEST COMPLAINCE 1 IEC PART 1 SWITCHGEAR AND CONTROL GEAR ASSEMBLIES IEC PART 2 POWER DISTRIBUTORS IEC PART 3 MOTOR CONTROL CENTER IEC PART 4 POWER CONTROL CENTER Collection by : Mr. Kiran IEC 61439 TESTS DYK: DO YOU KNOW?

IEC 61439 TESTS - web.s-cdn.boostkit.dev

  • Upload
    others

  • View
    60

  • Download
    3

Embed Size (px)

Citation preview

Page 1: IEC 61439 TESTS - web.s-cdn.boostkit.dev

The new Current initiative 16 June 2021

IEC 61439 1 & 2 IEC 61439, the one standard for all switchgear and control

gear assemblies is applicable to all power distributors, meter boxes and distribution enclosures for private and commercial buildings, assemblies for construction sites and power distribution. Certification of distribution assemblies is defined by international standard IEC 61439. This standard provides common rules that are recognised worldwide. Compliance with the standard is certified, depending on the country or market, by a declaration of the panel builder, the design office, the installer or the user.

Just to mention before going into test, that low voltage switchgear and control gear assemblies (Un ≤ 1000 V AC) may be used at the origin of an electrical installation with:

1. Low Voltage Main switchboard (transformer area)

2. Low Voltage Main Distribution Board (technical area)

Prisan REFERENCE - BCH TEST COMPLAINCE 1

IEC PART 1 SWITCHGEAR AND

CONTROL GEAR ASSEMBLIES

IEC PART 2 POWER

DISTRIBUTORS

IEC PART 3 MOTOR CONTROL

CENTER

IEC PART 4 POWER CONTROL

CENTER

Collection by : Mr. Kiran

IEC 61439 TESTS DYK: DO YOU KNOW?

Page 2: IEC 61439 TESTS - web.s-cdn.boostkit.dev

The new Current initiative 16 June 2021

TESTS AS PER IEC 61439

AUTHORISED SYSTEM INTEGRATOR

Sr No Clause / Subclause Test as per IEC 61439 part 1 and 2

1 10.2 Verification of strength of material and parts

2 10.2.2 Resistance to corrosion

3 10.2.5 Lifting

4 10.2.6 Mechanical Impact

5 10.2.7 Marking

6 10.2.3.1 Thermal stability

7 10.2.4 Resistance to UV radiation

8 10.2.3.2 Resistance to abnormal heat & fire due to internal electric effect

9 10.3 Degree of protection

10 10.4 Clearances and creepage distances

11 10.5 Protection against electrical shocks & Integrity of protection circuit

12 10.5.2 Effective continuity between exposed & integrity of protective circuit

13 10.5.3 Short circuit withstand strength of protective circuit

14 10.5.6 Incorporating of switching device & components

15 10.5.7 Internal electrical circuits and connections

16 10.5.9 Terminals for external conductors

17 10.9 Dielectric Properties Test

18 10.9.3 Impulse withstand voltage

19 10.9.2 Rated Insulation Voltage

20 10.10 Temperature rise limits

21 10.11 Short circuit withstand strength

22 10.12 Electromagnetic compatibility (EMC)

23 10.13 Mechanical operation

Prisan REFERENCE - BCH TEST COMPLAINCE 2