Measurement Job TypesSwissQual®®...QualiPoc
25Manual 1612011351 ─ 13.0.1
4 Measurement Job TypesYou can create and configure a measurement job in QualiPoc directly on your smart-phone or tablet, save the job locally, and run the job immediately. This section describesthe types of measurement jobs that you can create and run in QualiPoc.
4.1 Single CALL Job – Answering Station
The single call test - answering station job starts a measurement device in answeringstation mode. Once in this mode, another device can initiate MOC DL testing to theanswering station.
Fig. 4-1: Answering station single CALL job
Table 4-1: Description of the settings for an Answering station single CALL job
Setting Description
"Algorithm" Evaluates speech quality on the calling side.
"Reference File" Reference file for speech quality evaluation
4.2 Single CALL Job – Call to Any Number
A Call to Any Number job sets up a simple Circuit Switch (CS) call and outputs the maintest-related KPIs. This simple test requires you to input the following settings.
Single CALL Job – Answering Station
Measurement Job TypesSwissQual®®...QualiPoc
26Manual 1612011351 ─ 13.0.1
Fig. 4-2: Call to Any Number single CALL job
Table 4-2: Description of the settings for a Call to Any Number single CALL job
Setting Description
"Phone number" Number that you want to call
"Call duration" Duration of the call in seconds
"Number of cycles" Number of times to repeat a single test before the jobends
4.3 Single CALL Job – Speech MOC
A Speech MOC job sets up a Circuit Switch (CS) call to an answering station. This stationcan be part of the network, that is, an automatic voice announcement number in MSC, aDiversity Call Server that is running as an answering station, or another QualiPoc devicerunning in Answering Station mode, that is, single CALL job - Answering Station. Cur-rently, the job outputs the main test-related KPIs and MOS values of the speech in thedownlink.
For information on how to configure a Diversity Call Server as an answering station, seechapter A, "Creating an Answering Station for QualiPoc Android", on page 97.
Single CALL Job – Speech MOC
Measurement Job TypesSwissQual®®...QualiPoc
27Manual 1612011351 ─ 13.0.1
Fig. 4-3: Speech MOC DL single CALL job
Table 4-3: Description of the settings for Speech MOC single CALL job
Setting Description
"Phone number" Number that you want to call
"Call duration" Duration of the call in seconds
"Max call setup time" Maximum waiting time for the call to be set up
"Algorithm" Algorithm to evaluate speech quality
"Reference File" Reference file to play for speech quality evaluation
"Wave file options" Options for recording wave files during the test
For speech quality tests, you can use the SQUAD08 or POLQA (P.863) algorithm.
You need a valid QualiPoc Android license for the algorithm that you want to use.
Single CALL Job – Speech MOC
Measurement Job TypesSwissQual®®...QualiPoc
28Manual 1612011351 ─ 13.0.1
4.4 Single CALL Job - Speech Double Ended
The Speech Double Ended job establishes a CS call between two QualiPoc Androidphones, a QualiPoc Android phone and a Diversity Call Server, or QualiPoc Androidphone and a Diversity Smartphone without an MCM.
The Speech Double Ended job can only run on devices with Snapdragon S3 or S4 pro-cessors.
Fig. 4-4: Speech Double Ended job settings
Table 4-4: Description of the settings for a Speech Double Ended Job
Setting Description
"Side" Side of the call, that is, A or B-side
"Call direction" "A-side to B-side", "B-side to A-side", or "Alternating Call Sequence"
In Diversity, the call direction is in MOC:MTC format, that is, 1:0 for A to B, 0:1for B to A, and 1:1 for the "Alternating Call Sequence".
"Phone Number" Number that you want to call
"Advanced settings" Specify call timings, algorithm, and sample
"Number of cycles" Number of times to repeat a single test before the job ends
"Job Name" Name of the job
Diversity ignores this name.
"Timing and Scheduling" Settings to configure the duration of the job. The window timings are compat-ible with Diversity.
"Speech Double Ended" Specify the settings for the Speech Double Ended job
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
29Manual 1612011351 ─ 13.0.1
Setting Description
"Sample Direction" From A to B, B to A, or Half-Duplex
"Selected Algorithm" Select the algorithm to calculate quality scores, namely POLQA or SQuad08.
"Reference File" Speech sample to use for the call.
You need to re-select the reference file when you change the algorithm. Qual-iPoc reference files do not have the same names as Diversity reference files.
" Supervised Unit" QualiPoc to QualiPoc or with the stop call option where the phone operates asan autonomous B-side answering station.
Do not enable this option if the job involves a call to a Diversity unit.
"Remote Job Number" Unlike the job name, the value that you enter is transferred to a Diversity unitduring the call.
"Sample Frequency" Plays a sample each time that the interval that you specify elapses
4.4.1 Supported Measurement Scenarios
QualiPoc Android supports the following speech double ended measurement scenarios:
● QualiPoc Android to QualiPoc Android:– Manually configure the job in QualiPoc on the A-side and B-side phones.– Manually start the job in QualiPoc on the B-side and A-side phones, respectively.
For more information, see chapter 4.4.2, "Creating and Running the Job on a QualiPocPhone", on page 30.
● QualiPoc Android to Diversity Call Server (PSTN/ISDN):– Add and configure the Diversity voice call server in NQView.
For more information, see chapter 4.4.3.1, "Creating a Voice Call Server inNQView ", on page 38.
– Export the configuration of the voice call server from NQView and import theconfiguration on the voice call server.
– Manually configure the job on the QualiPoc phone.For more information, seechapter 4.4.2, "Creating and Running the Job on aQualiPoc Phone", on page 30.
– Add the QualiPoc phone as a mock voice call server in NQView.For more information, see chapter 4.4.3.1, "Creating a Voice Call Server inNQView ", on page 38.
– Manually create the task in NQView, export the B-side task configuration file, andimport the file on the voice call server.For more information, see chapter 4.4.3.2, "Creating the Speech Double EndedMeasurement Task in NQView", on page 41.
– Manually start the job on the QualiPoc phone.For more information, see chapter 4.4.2.1, "Starting the Job on the QualiPocPhone", on page 37. The QualiPoc phone must be the A-side device.
● Diversity Android Smartphone without an MCM/PSM to QualiPoc Android:– Add and configure the Diversity smartphone . For more information, see
the Manual – NetQual – NQView.pdf document.
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
30Manual 1612011351 ─ 13.0.1
– Manually configure the job on the QualiPoc phone. For more information, seechapter 4.4.2, "Creating and Running the Job on a QualiPoc Phone",on page 30. Some Diversity settings are slightly different than the QualiPoccounterparts. In such cases, consult the setting information in the paragraphbelow the relevant step.
● Diversity Android Smartphone without an MCM/PSM to QualiPoc Android:– Add the QualiPoc phone as a mock DTMF voice call server in NQView.
For more information, see chapter 4.4.3.1, "Creating a Voice Call Server inNQView ", on page 38.
– Create the measurement task in NQView with the Diversity smartphone as theA-side device and the QualiPoc phone, that is, the mock DTMF voice call server,as the B-side device.For more information, see chapter 4.4.3.2, "Creating the Speech Double EndedMeasurement Task in NQView", on page 41.
– Manually start the job on the QualiPoc phone.For more information, see chapter 4.4.2.1, "Starting the Job on the QualiPocPhone", on page 37.
– Start the measurement task in NQView.For more information, see chapter 4.4.3.3, "Starting the Measurement Task inNQView", on page 43. A Diversity smartphone only supports the DTMF jobtransfer method. The Diversity smartphone must be the A-side device and theQualiPoc Android phone must be the B-side device.
● Diversity Smartphone in an MCM/PSM to QualiPoc Android:– Same as the Diversity Android Smartphone without an MCM/PSM to QualiPoc
Android scenario except that you need to include an MCM in the NQView hard-ware configuration
4.4.2 Creating and Running the Job on a QualiPoc Phone
The settings that you specify for the measurement job on the A-side device must beidentical to the settings on the B-side device, except for the respective phone numbersand test direction.
To create a Speech Double Ended measurement job in QualiPoc
1. Press Menu and touch "Jobs > Selected job type > Single CALL tests > SpeechDouble Ended".
2. Configure the basic job settings.
a) Touch "Selected side" and then touch a side, for example, "A".
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
31Manual 1612011351 ─ 13.0.1
b) Touch "Selected phone number > Add new", enter the number for the A-sidephone, and then touch "OK".
Fig. 4-5: Create a QualiPoc Speech Double Ended measurement job
3. Touch "Advanced settings > Job name", enter a name for the job, and then touch"OK".
Fig. 4-6: Specify the job name
4. Specify the timing settings for the job.
a) Touch "Timings and Scheduling".
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
32Manual 1612011351 ─ 13.0.1
b) Touch "Duration", enter a value, and then touch "OK".For a test that involves a Diversity unit, enter the same duration as you did infigure 4-16 for the measurement task in NQView.
c) Touch "# of Cycles", enter a value, and then touch "OK".For a test that involves a Diversity unit, enter the same duration as you did infigure 4-16 for the measurement task in NQView.
Fig. 4-7: Timings and Scheduling
d) Touch "Pause time", enter a value and then click "OK".This setting is only available in QualiPoc and must be 0 if the test involves aDiversity unit.
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
33Manual 1612011351 ─ 13.0.1
e) Touch "Window Timings" and use the timings picker at the top left to select thesetting that you want to change, and then use the value picker at the top right toselect the new value.For a test that involves a Diversity unit, specify the same Window timings as youdid in figure 4-17 for the intrusive job in NQView.
Fig. 4-8: Window timings
f) Press Back .
5. Specify the test settings.
a) On the "Job settings" screen, touch "Speech Double Ended" in the "Test" area.
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
34Manual 1612011351 ─ 13.0.1
b) Touch "Selected call direction" and touch the call direction.For a test that involves a Diversity unit, the call direction is the "MOC:MTC" ratioin figure 4-17 that you specified for the intrusive job in NQView. For a"MOC:MTC" ratio of 1:0, touch "Call A to B", for a "MOC:MTC" ratio of 0:1, touch"Call B to A", and for "MOC:MTC" ratio of 1:1, touch "Alternating CallSequence".
Fig. 4-9: Set Call Direction
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
35Manual 1612011351 ─ 13.0.1
c) Touch "Selected sample direction", and then touch an option in the list.Unlike in Diversity, the half-duplex option in QualiPoc always starts with a B to Asample direction and then alternates the sample direction. Furthermore, unlike inDiversity, you cannot specify the number of samples that a QualiPoc job uses.However, QualiPoc always evaluates the reference samples that the phonereceives. For a test that involves a Diversity unit, ensure that the sample directionthat you selected in figure 4-18 for the test in NQView reflects these limitations.
Fig. 4-10: Speech Double Ended test settings
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
36Manual 1612011351 ─ 13.0.1
d) Touch "Selected algorithm" and touch one of the following options.
● "SQuad08": for a "Speech" test● "SQuad08 (WB)": For a "Speech-Wideband" test● "POLQA": For a "Speech POLQA" test● "POLQA (WB)": For a "Speech-Wideband POLQA" test
For a test that involves a Diversity unit, touch the algorithm that you selected infigure 4-18 for the test in NQView.
Fig. 4-11: Select the algorithm for the test
e) Touch "Selected reference file" and touch a sample file for the test.For a test that involves a Diversity unit, use same reference sample that youselected in figure 4-18 for the test in NQView, for example, "English (U.S.) IRS"for the AM_fm_IRS.wav reference sample.
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
37Manual 1612011351 ─ 13.0.1
f) Touch "Sample frequency", enter one of the following sample frequencies, andthen touch "OK":
● 12.5: For tests that use the "SQuad08" and POLQA algorithms.The sample frequency is the time difference between the start times of thetwo subsequent samples. A sample frequency of 12.5 seconds in QualiPoccorresponds to the combined 6 second "Record hang-over" that you specifiedin figure 4-18 in NQView and the 6.5 second duration of the SwissQual ref-erence samples.
● 20: For tests that use the "SQuad08 (WB)" and "POLQA (WB)" algorithms.QualiPoc on slower phones requires the longer time to calculate the MOSresults in a wideband Speech Double Ended measurement job.
Fig. 4-12: Additional Speech Double Ended test settings
g) Touch "Selected wave file option" and touch an option.
4.4.2.1 Starting the Job on the QualiPoc Phone
► To start the job, press Menu , touch "Jobs", ensure that the Speech Double Endedjob is loaded, and touch "Start job".
► To load the job, press Menu , touch "Load job", touch "Speech Double Ended",and touch the job that you created.
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
38Manual 1612011351 ─ 13.0.1
4.4.2.2 Stopping the Job on the QualiPoc Phone
The B-side QualiPoc device handles a stop command from the Diversity A-side devicein the following ways:
● Stop command arrives during a configuration call: QualiPoc restarts the mea-surement job into waiting for configuration mode and does not save a measurementfile
● Stop command arrives during a normal call: QualiPoc stops the measurement joband saves a measurement file.
● Stop command arrives during a pause in a normal call: Job continues to run untilthe timeout is reached
● Stop command does not arrive: If the call has already been configured and the testis running, the call runs indefinitely; however, if you restart the measurement task inNQView and QualiPoc is configured to receive the call, then QualiPoc restarts thejob on the phone after the configuration call.
4.4.3 Creating and Running the Job in Diversity NQView
The following sections describe how to use Diversity NQView to configure the followingfeatures for a speech double ended test:
● Voice Call Server: Required for the QualiPoc Android to Diversity Call Server (PSTN/ISDN), Diversity Android Smartphone without an MCM/PSM to QualiPoc Android,and Diversity Smartphone in an MCM/PSM to QualiPoc Android scenarios
● Speech Double Ended Measurement Task: Required for the Diversity AndroidSmartphone without an MCM/PSM to QualiPoc Android, and Diversity Smartphonein an MCM/PSM to QualiPoc Android scenarios
● Starting the Measurement Task in NQView
4.4.3.1 Creating a Voice Call Server in NQView
This section describes how to configure a physical Diversity voice call server with PSTNor ISDN cards in NQView as well as a mock Diversity voice call server. The mock callserver represents the QualiPoc unit when you configure a mixed environment Diversityand QualiPoc speech double ended task in NQView.
For the Diversity smartphone to QualiPoc phone scenario, the following sections assumethat have already configured the Diversity smartphone for the test. For the QualiPoc toVoice Call Server scenario, the following procedure assumes that you have alreadyinstalled the ISDN or PSTN devices and the respective Windows drivers on the PC thathosts the voice call server.
To create a mock voice call server in NQView
1. On the Navigation panel of the "Control" console, click "System configuration".
2. Add a PC unit.
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
39Manual 1612011351 ─ 13.0.1
a) Right-click "Hardware", point to "Add unit", and then click PC.
Fig. 4-13: Add PC unit to system configuration
b) Type a "Name" and "Computer name" for the unit, for example, QPAndroid.
Fig. 4-14: Create a voice call server
c) In the "Time synchronization" list, click "Internal sync".d) In the following lists, click "No connection/DTMF":
● "NQComm control"● "Unit control"● "Job transfer send"● "Job transfer listen"
e) Click "Apply" and click "OK".
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
40Manual 1612011351 ─ 13.0.1
3. Create a subscriber profile for the phone device or PSTN or ISDN card.
a) Click "System configuration" on the Navigation panel and click the plus sign (+)beside "Subscriber and access points".
b) Click the plus sign (+) beside an operator in the tree, right-click a provider, andthen click "Add subscriber".
c) Add the subscriber information, click "Apply", and then click "OK".
4. Add the QualiPoc phone or the PSTN or ISDN card as device to the DTMF voice callserver.
a) Right-click the unit in the tree, point to "Add device", and then click the type ofdevice, for example "Mobile" for a QualiPoc phone or "ISDN" for a Diversitydevice.
b) Type a name for the phone.c) In the "Model" list, click the type of phone or ISDN or PSTN model.d) In the "Subscriber" list, click the profile that you created in the previous step.
If you are creating a mock call server for a QualiPoc phone, the subscriber numberis the only value that needs to be identical to the QualiPoc setting.
e) Click "Apply" and click "OK".
Fig. 4-15: Add a device to the voice call server
5. Transfer the configuration to the voice call server PC.You do not need to perform this action for the QualiPoc mock voice call server.For a description on how to transfer the configuration to the voice call server, seechapter B, "Configuring Voice and Video Call Servers", on page 108.
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
41Manual 1612011351 ─ 13.0.1
4.4.3.2 Creating the Speech Double Ended Measurement Task in NQView
The following procedure assumes that you have already configured the Diversity deviceinvolved in the test, for example, the Diversity smartphone.
To define the Speech Double Ended measurement task in NQView
1. On the Navigation panel of the "Control" console, click "Tasks and Jobs", right-click"Measurement task" in the tree, and then click "Add task".
2. Type a name for the task.
Fig. 4-16: Add a measurement task
3. In the "Device A/B side" area, select the A-side and B-side devices.
Scenario A-Side Device B-Side Device
QualiPoc to Diversity Call Server(PSTN/ISDN) scenario
QualiPoc phone (mock callserver)
Diversity call server (PC)
Diversity Android Smartphonewithout an MCM/PSM to Quali-Poc Android
Diversity Android Smartphone QualiPoc phone (mock callserver)
Diversity Smartphone in anMCM/PSM to QualiPoc Androidscenarios
Diversity Android Smartphone QualiPoc phone (mock callserver)
4. Add a measurement job to the taskImportant: You need to use the same job settings that you manually specified on theQualiPoc phone in chapter 4.4.2, "Creating and Running the Job on a QualiPocPhone", on page 30.
a) In the "Job sequence" area, click the green plus sign .
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
42Manual 1612011351 ─ 13.0.1
b) Click the yellow asterisk in front of the "Job" list, and then click "Intrusive job".
Fig. 4-17: Add an intrusive job to the measurement task
c) In the "Name" box, type a name for the job in the following DTMF job transferformat:
● job_xyzd) In the "Record hang-over [ms]" box, type 6000.
QualiPoc does not have a hang-over recording setting. Instead, you need tospecify a "Record Hang-Over" value of 6000ms and a "Test RepetitionSequence" of 11 in NQView.
e) In the "MOC:MTC ratio" box, specify the call direction, for example, 1:1.QualiPoc does not use the MOC:MTC ratio to define the call direction, but ratheruses A-side and B-side. As a result, a MOC:MTC ratio of 1:0 corresponds to theA to B call direction setting in QualiPoc and a 0:1 ratio corresponds to B to A.However, the MOC:MTC ratio of 1:1 corresponds to the"Alternating CallSequence" call direction in QualiPoc.
f) In the "Timings" area, select "Use call duration to abort call".If you do not enable this option, the measurement task will not run correctly
g) Specify the remaining timings, click "Apply", and then click "OK".
5. In the "Intrusive test" window, specify the settings for the speech test.
a) Type a name for the test.
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
43Manual 1612011351 ─ 13.0.1
b) In the "Test type" list, click one of the following types:
● "Speech"● "Speech POLQA"● "Speech-Wideband"● "Speech-Wideband POLQA"
c) In the "Direction" area, click a direction for the reference sample.You need to select the same direction for all of the reference samples that youuse. Samples with alternating directions must start with a B to A direction; oth-erwise NQView does not accept the configuration on the task level.
d) In the "Reference sample" list, click the speech sample that you want to use.e) In the "Save WAV files" area, click an option.f) Click "Apply" and then click "OK"
Fig. 4-18: Add a speech test to the intrusive job
6. In the "Job details in task" window, click "Save".
7. In the "Measurement task" window, specify the "Duration" and the number of"Cycles" for the task.
8. Click "Apply", and then click "OK".
Note: For a description on how to transfer the task configuration to a Diversity voicecall server, see chapter B, "Configuring Voice and Video Call Servers",on page 108.
4.4.3.3 Starting the Measurement Task in NQView
This section describes how to start the Speech Double Ended Measurement in NQViewand on the QualiPoc phone.
To start the measurement task on NQView
1. On the "Control" console in NQView, click "Tasks and Jobs".
2. Click the "Tasks" tab in the workspace.
3. Click the green arrow in the "Start" column in front of the task that you created.
Single CALL Job - Speech Double Ended
Measurement Job TypesSwissQual®®...QualiPoc
44Manual 1612011351 ─ 13.0.1
4.5 Single DATA Job – Capacity DL
Capacity DL tests can execute up to 4 parallel HTTP downloads at once.
Fig. 4-19: Capacity DL single DATA job
Table 4-5: Description of the settings for a Capacity DL single DATA job
Setting Description
"URLs" HTTP address of the site that you want to download
"Advanced Settings" Specify advanced timeouts and test options
"Number of cycles" Number of times to repeat a single test before the jobends
Ensure that the total download size of the reference files is large enough to last for theduration of the test.
4.6 Single DATA Job – Email Send and Receive
The email test supports SMTP, POP3, IMAP, and SSL.
Single DATA Job – Capacity DL
Measurement Job TypesSwissQual®®...QualiPoc
45Manual 1612011351 ─ 13.0.1
Fig. 4-20: Email Send single DATA job
Table 4-6: Description of the settings for a Email Send and Receive single DATA job
Setting Description
"Outgoing and Incoming mail server" Address of the email serve
"Advanced Settings" Specify advanced timeouts and test options
"Number of cycles" Number of times to repeat a single test before the jobends
4.7 Single DATA Job – FTP DL and UL
FTP Transfer DL and UL jobs establish a Packet Switch call, execute an FTP transfer,and measure the test- related performances. You need to enter the following settings toconfigure an FTP job.
Single DATA Job – FTP DL and UL
Measurement Job TypesSwissQual®®...QualiPoc
46Manual 1612011351 ─ 13.0.1
Fig. 4-21: FTP DL and UL single DATA jobs
● Host address: IP address of the host
To add the port number, type a colon (:) at the end of the address, and then type the portnumber. Only QualiPoc Handheld uses this number.
Table 4-7: Description of the settings for FTP DL and UL single DATA jobs
Setting Description
"File" Name of the remote file that you want to download
"Credentials" Login credentials for the FTP server
"Advanced Settings" Specify advanced timeouts and test options
"Number of cycles" Specify the number of times to repeat a single testbefore the job stops
4.8 Single DATA Job – HTTP Browser
An HTTP Browsing job establishes a Packet Switch (PS) call and performs a browsingtest to output test relevant results. For this test QualiPoc application uses the same webengine as the built in browser does. In order to run the test you need to specify the fol-lowing settings for an HTTP Browsing job.
Single DATA Job – HTTP Browser
Measurement Job TypesSwissQual®®...QualiPoc
47Manual 1612011351 ─ 13.0.1
Fig. 4-22: HTTP Browser single DATA job
Table 4-8: Description of the settings for an HTTP Browser single DATA job
Setting Description
"URL" HTTP address of the site that you want to browse
"Advanced Settings" Specify advanced timeouts and test options
"Number of cycles" Number of times to repeat a single test before the jobends
4.9 Single DATA Job – HTTP Transfer DL and UL
The HTTP Transfer Download (DL) and Upload (UL) jobs establish a Packet Switch (PS)call, execute an HTTP transfer, and measures the test-related performances. You needto enter the following settings for these tests.
Single DATA Job – HTTP Transfer DL and UL
Measurement Job TypesSwissQual®®...QualiPoc
48Manual 1612011351 ─ 13.0.1
Fig. 4-23: HTTP Transfer DL and UL single DATA jobs
Table 4-9: Description of the settings for HTTP Browser Transfer DL and UL single DATA jobs
Setting Description
"Host address" IP address of the host
"File" Name of the remote file that you want to download
"Credentials" Login credentials for the HTTP server
"Advanced Settings" Specify advanced timeouts and test options
"Number of cycles" Number of times to repeat a single test before the jobends
4.10 Single DATA Job - Iperf UDP
The Iperf test allows you to measure network capacity with UDP streams.
1. Press Menu and touch "Jobs > Selected job type > Single DATA tests > Iperf".
Single DATA Job - Iperf UDP
Measurement Job TypesSwissQual®®...QualiPoc
49Manual 1612011351 ─ 13.0.1
Fig. 4-24: Iperf DATA job settings and Advanced settings
2. Touch "Selected server address", touch "Add new", enter the name of the server, andthen touch "OK".
3. Specify the test settings.
a) Touch "Iperf" in the "Test" area.b) To add a command-line setting, touch "Selected additional parameters", enter
the setting, and then touch "OK".
Fig. 4-25: Iperf test settings and parameters
Single DATA Job - Iperf UDP
Measurement Job TypesSwissQual®®...QualiPoc
50Manual 1612011351 ─ 13.0.1
Note: To view the list of available parameters, touch "Full arguments list".
4.10.1 Overview of Iperf Parameters
Setting Description
-f, --format [kmKM] Format to report: Kbits, Mbits, KBytes, MBytes
-i, --interval # Seconds between periodic bandwidth reports
-l, --len #[KM] Length of buffer to read or write (default 8 KB)
-m, --print_mss Print TCP maximum segment size (MTU - TCP/IPheader)
-o, --output <filename> Output the report or error message to this specifiedfile
-p, --port # Server port to listen on/connect to
-u, --udp Use UDP rather than TCP
-w, --window #[KM] TCP window size (socket buffer size)
-B, --bind <host> Bind to <host>, an interface or multicast address
-C, --compatibility For use with older versions does not sent extra msgs
-M, --mss # Set TCP maximum segment size (MTU - 40 bytes)
-N, --nodelay Set TCP no delay, disabling Nagle's Algorithm
-V, --IPv6Version Set the domain to IPv6
For the –l and –w, –K or –M parameters, suffixes are required, for example, “–l 8K”, or“–w 512K”. QualiPoc supports the UDP protocol and automatically adds the –u param-eter.
Single DATA Job - Iperf UDP
Measurement Job TypesSwissQual®®...QualiPoc
51Manual 1612011351 ─ 13.0.1
Fig. 4-26: Iperf log with the client report outlined in red
The client report in the Iperf log has the following fields:● 20130104135043 date/time● 10.105.30.236 sender IP address● 34548 sender port (UDP)● 82.220.1.20 receiver IP address● 5001 receiver port● 4 ID● 1.0-2.0 Interval in seconds● 132300 data transferred in Bytes● 1058400 bandwidth in bits/s
The final report datagram from the client and server has a total of 14 fields, 9 from theclient report, and the following 5 fields:● 6.429 Delay jitter● 10 quantity of lost packets● 893 quantity of received packets● 1.120 lost packets in %● 0 quantity of packets out of order
4.11 Single DATA Job – Ping
A Ping job establishes a Packet Switch call and pings the host that you specify to evaluatethe Round Trip Time (RTT). You need to specify the following settings for a Ping job.
Single DATA Job – Ping
Measurement Job TypesSwissQual®®...QualiPoc
52Manual 1612011351 ─ 13.0.1
Fig. 4-27: Ping single DATA job
Table 4-10: Description of the settings for a Ping job
Setting Description
"Host" IP address of the host
"Number of pings and interva" Number of pings and interval between pings in milli-seconds
"Packet size and timeout" Enter the packet size in bytes and the timeout for theping in seconds
"Advanced Settings" Specify advanced timeouts and test options
"Number of cycles" Number of times to repeat a single test before the jobends
4.12 Single DATA Job - Upload
The Upload job uploads the results files to the server that you specify in the job settings.
This job uploads the files from the results folder that you define in the unit configurationsettings.
Single DATA Job - Upload
Measurement Job TypesSwissQual®®...QualiPoc
53Manual 1612011351 ─ 13.0.1
To create an Upload measurement job
1. Press Menu and touch "Jobs > Selected job type > Single DATA tests >Upload".
2. Specify the server for the job.
a) Touch "Host address".
Fig. 4-28: Job settings for the Upload measurement job
b) In the "Result files upload connection profile" area, touch "Select connectiontype".
c) Touch a connection type in the list, for example, "FTP" or "HTTP".d) Touch "Select host", enter the URL for the server, and then touch "OK".e) Select active or passive mode.
3. Specify the login information for the server.
a) Touch "Select user name", enter an account name, and touch "OK".b) Touch "Password", enter the password for the account, and touch "OK".
4. Specify the remaining settings, for example, enable the "Auto upload" and "Autocompression" options.
Single DATA Job - Upload
Measurement Job TypesSwissQual®®...QualiPoc
54Manual 1612011351 ─ 13.0.1
Fig. 4-29: Results file settings
Note: You cannot specify timings for an Upload job.
4.13 Single MESSAGE Job – MMS Send and Receive
You can add up to two attachments to an MMS test.
Single MESSAGE Job – MMS Send and Receive
Measurement Job TypesSwissQual®®...QualiPoc
55Manual 1612011351 ─ 13.0.1
Fig. 4-30: MMS Send MESSAGE job
Table 4-11: Description of the settings for MMS Send and Receive single MESSAGE jobs
Setting Description
"Receiver number" Number of the receiver
"Advanced Settings" Specify advanced timeouts and test options
"Number of cycles" Number of times to repeat a single test before the jobends
4.14 Single MESSAGE Job – SMS Send and Receive
The SMS test allows you to configure the following options.
Single MESSAGE Job – SMS Send and Receive
Measurement Job TypesSwissQual®®...QualiPoc
56Manual 1612011351 ─ 13.0.1
Fig. 4-31: SMS Send MESSAGE job
Table 4-12: Description of the settings for SMS Send and Receive single MESSAGE jobs
Setting Description
"Receiver number" Number of the receiver
"Advanced Settings" Specify advanced timeouts and test options
"Number of cycles" Number of times to repeat a single test before the jobends
4.15 Single VIDEO Job - YouTube No Reference
The YouTube No Reference test calculates the following quality values:
● Configuration access time [s]: KPI 10620● Pre-buffering time [s]: KPI 30621● Video download time [s]: KPI 20625● Video Duration [s]: Length of the video● Video Display time [s]: Duration of the recorded video sequence● Time to ready to play [s]: Time from sending the first TCP SYN packet to the YouTube
server until completing the download of the player configuration● Time to start buffering [s]: KPI 10625● Time to first picture [s]: Time from sending the first TCP SYN packet to YouTube
server until the first video frame is displayed on the screen● Freezing [%] in relation to video display time● Jerkiness [%] in relation to video display time
Single VIDEO Job - YouTube No Reference
Measurement Job TypesSwissQual®®...QualiPoc
57Manual 1612011351 ─ 13.0.1
You cannot use copyrighted videos or videos that have had embedding disabled.
Fig. 4-32: YouTube single VIDEO job
The YouTube No Reference job supports the following link types:
● Full address http://www.youtube.com/watch?v=-UaMoP-D1VY● ID only -UaMoP-D1VY● Mobile site m.youtube.com/watch?v=-UaMoP-D1VY● Short address youtu.be/watch?v=-UaMoP-D1VY
You can also share a link from the Android YouTube application with QualiPoc.
Single VIDEO Job - YouTube No Reference
Measurement Job TypesSwissQual®®...QualiPoc
58Manual 1612011351 ─ 13.0.1
Fig. 4-33: YouTube No Reference test settings
Fig. 4-34: YouTube single VIDEO job results
Single VIDEO Job - YouTube No Reference
Measurement Job TypesSwissQual®®...QualiPoc
59Manual 1612011351 ─ 13.0.1
4.16 Multiple Jobs – Multi-Data / Multi-Mix / Multi-RAB / Par-allel
Multiple jobs allow you to combine Data and Voice jobs into a single job. This optionsupports all single data and call tests.
● Multi-Data: Sequence of data tests in which all the tests occur in one session● Multi-Mix: Sequence of data and call tests in which a new session starts for each
test● Multi-RAB: Parallel execution of a call and a multi-data test● Parallel: Parallel execution of up to 3 parallel jobs independent from each other (one
call job and multiple single or multi-data jobs).
Fig. 4-35: Mult-Mix job settings
4.17 Job Sequence
A "Job Sequence" allows you to specify the sequence of single-sided measurement jobsfor a slave to perform. If you have created measurement jobs that run on all of the slaves,then you can also specify a sequence for all of the slaves. In both cases, QualiPoc savesa separate measurement files for each job that runs.
To create a job sequence
1. Press Menu and touch "Jobs > Selected job type".
2. In the "Select Job Group" list, touch "Job Sequence".
Multiple Jobs – Multi-Data / Multi-Mix / Multi-RAB / Parallel
Measurement Job TypesSwissQual®®...QualiPoc
60Manual 1612011351 ─ 13.0.1
Fig. 4-36: Job sequence
3. Touch "Taskname" and type a name for the sequence.
Fig. 4-37: Job sequence settings
4. Add a job to the sequence.
a) In the "Job Quick Start Settings" area, touch "Job Sequence contains".b) In the "Select Job Group" list, touch a group that contains a job that you want to
include, for example, "Single DATA job".
Job Sequence
Measurement Job TypesSwissQual®®...QualiPoc
61Manual 1612011351 ─ 13.0.1
c) In the "Select Job Type" list, touch the type of job that you want to include, forexample, "FTP DL".The Answering Station single CALL Job is not available.
d) In the "Select a job file" list, touch a job, for example, "LastJobFTPDL.xml".
Fig. 4-38: Jobs in a sequence
Note: If you touch "Add new", see chapter 5.3, "Creating and Running Basic Jobs",on page 65 or chapter 5.4, "Creating and Running Advanced Jobs", on page 66.You can only specify the number of cycles and test duration "Timings and Schedul-ing" options for the individuals.
5. Press Back and on the "Job Sequence" screen, press Menu and touch "Addjob" to add an additional job.
Note: Repeat this step for each additional job.
6. To start the "Job Sequence", press Back , and touch "Start Job".
4.18 Advanced Job Settings
You can also specify the following advanced settings for each job.
Advanced Job Settings
Measurement Job TypesSwissQual®®...QualiPoc
62Manual 1612011351 ─ 13.0.1
Fig. 4-39: Advanced settings
Setting Description
"Timings and scheduling" Time and date on which to start the job, the number of repetitions for the job, andthe related timings, for example, duration of the job, pause between the tests,and so on
"Test" Settings that are related to the job
"Access Point" Network access point for the job
"Pcap" Include the PCAP information to the measurement file
Advanced Job Settings