Gulliver BSF_TS0059UK01.pdf

Embed Size (px)

Citation preview

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    1/20

    The Riello Gulliver BSF series of one stage gas burners, is a complete range of productsdeveloped to respond to any request for light industrial processes like bakery ovens, spraypainting ovens, small steam or thermal boilers and all applications which require a reliable,user-friendly industrial product with enhanced performance and specific functions.The Gulliver BSF series is available in four different models, with an output ranging from16 to 246 kW, divided in four different structures.All the models use the same components designed by Riello for the Gulliver series andhave the same ventilation system and overall dimensions as the previous one stage gasmodels. The Gulliver BSF burners are fitted with a microprocessor - based flame controlpanel, with diagnostic functions.This new series can operates on 50 or 60 Hz and a Voltage 220 - 230 Volt (dual frequency).

    All these burners are conform to the EN 676 Standard (Forced draught gas burners) and toEuropean Directives for EMC, Low Voltage and Gas Appliance. For depressurised workingfield see EN 746-2 Standard.All the Gulliver BSF burners are fired before leaving the factory.

    TS0059UK01

    LOW NOx ONE STAGE GAS BURNERSGULLIVER BSF SERIES BS1F 16 52 kW

    BS2F 35 91 kW

    BS3F 65 189 kW

    BS4F 110 246 kW

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    2/20

    TECHNICAL DATA

    Approval

    F

    uel/airdata

    Electricaldata

    Emissions

    BS1F BS2F BS3F BS4F

    One stage

    --

    --

    --

    16 - 52 35 - 91 65 - 189 110 - 246

    13,8 - 44,7 30,1 - 78,2 55,9 - 162,5 94,6 - 211,6

    0/40

    10

    0,71

    1,6 - 5,2 3,5 - 9,1 6,5 - 18,9 11 - 24,6

    8,6

    0,78

    1,9 - 6 4,1 - 10,6 7,6 - 22 12,8 - 28,6

    25,8

    2,020,6 - 2 1,4 - 3,5 2,5 - 7,3 4,3 - 9,5

    Centrifugal with forward curve blades

    40

    1/50 - 60/220 - 230 10%

    --

    MG 569

    0,135(at 50 Hz) - 0,165(at 60 Hz) 0,155(at 50 Hz) - 0,200(at 60 Hz)0,355(at 50 Hz) - 0,485(at 60 Hz)0,420(at 50 Hz) - 0,600(at 60 Hz)

    --

    X0D

    0,09 0,09 0,15 0,25

    0,6(at 50 Hz) - 0,75(at 60 Hz) 0,7(at 50 Hz) - 0,9(at 60 Hz) 1,6(at 50 Hz) - 2,2(at 60 Hz) 1,9(at 50 Hz) - 2,7(at 60 Hz)

    2,4(at 50 Hz) - 3(at 60 Hz) 2,8(at 50 Hz) - 3,6(at 60 Hz) 6,4(at 50 Hz) - 8,8(at 60 Hz) 7,6(at 50 Hz) - 10,8(at 60 Hz)

    20

    Incorporated in the control box

    230 V - 8 kV

    0,2 A - 12 mA

    Intermittent (at least one stop every 24 h)

    61 62 66 71

    --

    20 10 20 10

    75 70 75 65

    90/396/EEC, 89/336/EEC, 73/23/EEC

    EN 676 - EN 746-2

    In progress

    type

    s

    kW

    Mcal/h

    C min./max.

    kWh/Nm3

    kg/Nm3

    Nm3/h

    kWh/Nm3

    kg/Nm3

    Nm3/h

    kWh/Nm3

    kg/Nm3

    Nm3/h

    type

    max C

    Ph/Hz/V

    Ph/Hz/V

    type

    kW

    kW

    IP

    kW

    A

    A

    IP

    type

    V1 - V2

    I1 - I2

    dB (A)

    W

    mg/kWh

    mg/kWh

    Model

    Burner operation mode

    Modulation ratio at max. output

    Servomotorrun time

    Heat output

    Working temperature

    Net calorific value G20 gas

    G20 gas density

    G20 gas delivery

    Net calorific value G25 gas

    G25 gas density

    G25 gas delivery

    Net calorific value LPG gas

    LPG gas densityLPG gas delivery

    Fan

    Air temperature

    Electrical supply

    Auxiliary electrical supply

    Control box

    Total electrical power

    Auxiliary electrical power

    Protection level

    Motor electrical power

    Rated motor current

    Motor start up current

    Motor protection level

    Ignition transformer

    Operation

    Sound pressure

    Sound power

    CO emission

    NOx emission

    Directive

    Conforming to

    Certification

    Reference conditions:

    Temperature: 20C

    Pressure: 1013 mbar

    Altitude: 0 m a.s.l.

    Noise measured at a distance of 1 meter.

    Since the Company is constantly engaged in the production improvement, the aesthetic and dimensional features,the technical data, the equipment and the accessories can be changed.This document contains confidential and proprietary information of RIELLO S.p.A. Unless authorised, this informationshall not be divulged, nor duplicated in whole or in part.

    2

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    3/203

    FIRING RATES

    35

    0

    5

    10

    15

    20

    25

    30

    -20

    -15

    -10

    -5

    45

    40

    50

    0

    0,5

    Mcal/h

    1,0

    1,5

    2,0

    2,5

    3,0

    3,5

    232,2206,4180,6154,8129,0103,251,625,80

    -0,5

    -1,0

    -1,5

    -2,0

    77,4

    4,0

    4,5

    5,0

    kW27024021018015012060300 90

    BS3F

    hPa(mbar)

    mmH2O

    BS1F

    BS2F

    BS4F

    Test conditions conforming to EN 676:

    Temperature: 20 C

    Pressure: 1013 mbar

    Altitude: 0 m a.s.l.

    Useful working field for choosing the burner

    IMPORTANT: For the part of the working field that is depressurised, refer to EN 746-2 Standard.

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    4/20

    The burners are set for fuel supply from either the right orleft hand sides.

    Depending on the fuel output and the available pressure inthe supply line, you should check the correct gas train tobe adapted to the system requirements.

    The gas train is Multibloc type, containing the maincomponents in a single unit.Except for the MBC 65 DLE model, a valve seal control (asaccessory) can be fitted to the Multibloc gas trains.

    The MBC 65 DLE Multibloc gas train can be fitted only tothe left of the burner.

    GAS TRAIN

    FUEL SUPPLY

    Gas train installed on the burner

    MBDLE 403 - 405 - 407 - 410 - 412

    L1 L

    LEAK DETECTION CONTROL DEVICE

    MULTIBLOC

    5

    9

    6

    7 8

    12

    3

    4

    P2

    10

    12

    P1

    1

    2

    3

    4

    5

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    P1

    P2

    P3

    L

    L1

    Gas delivery pipe

    Manual valve

    Vibration damping joint

    Gas pressure gauge

    Filter

    Gas pressure switch

    Safety solenoid

    Adjustment solenoid:

    firing delivery adjustment (rapid opening)

    maximum delivery adjustment (slow opening)

    Pressure regulator

    Leak detection control device for valves 7 and 8 (accessory)

    Gas train-burner adapter

    Burner

    Shutter with adjustment screws

    Pressure regulator setting device

    Regulation solenoid

    Combustion head pressure

    Upstream pressure from the filter

    Upstream pressure from the control valve

    Gas train supplied separately

    To be performed by the installer

    MBC 65 DLE

    L1 L

    MULTIBLOC

    5

    6

    7 15

    12

    3

    4

    P2

    12

    P1

    P3

    13

    13

    14

    9 11

    11

    4

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    5/20

    MULTIBLOC

    NameMBC 65 DLE

    MBDLE 403

    MBDLE 405

    MBDLE 405

    MBDLE 407

    MBDLE 407

    MBDLE 410

    MBDLE 412

    Code

    3970570

    3970545

    3970546

    3970547

    3970544

    3970548

    3970549

    3970550

    i

    1/2"

    1/2"

    1/2"

    3/4"

    3/4"

    3/4"

    1" 1/4

    1" 1/4

    o

    FLANGE 1

    FLANGE 1

    FLANGE 1

    FLANGE 2

    FLANGE 2

    FLANGE 3

    FLANGE 3

    FLANGE 3

    X mm

    232

    200

    246

    236

    236

    236

    259

    259

    Y mm

    126

    137

    186

    186

    186

    186

    215

    215

    Z mm

    122

    100

    120

    120

    120

    120

    145

    145

    W mm

    45

    45

    45

    47

    47

    47

    47

    47

    V mm

    31

    26

    46

    46

    46

    46

    55

    55

    mbar max*

    65

    300

    300

    300

    300

    300

    300

    300

    * max inlet gas pressure (mbar)

    Y

    Z X

    Y

    Z X

    i

    W

    W

    V

    V

    The dimensions of the gas trains vary depending on their construction features.The following table shows the dimensions of the gas trains that can be fitted to Gulliver BSF burners,intake diameter and the coupling flange to the burner.

    5

    i o

    o

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    6/20

    PRESSURE DROP DIAGRAM

    The diagrams indicate the minimum pressure drop of the burners with the various gas trains thatcan be combined with them; the value thus calculated represents the minimum required input

    pressure to the gas train.

    NATURAL GAS LPG

    BS1F BS1F

    10

    12

    18

    0

    2

    6

    8

    16

    26

    14

    4

    20

    24

    22

    0

    2

    6

    8

    1 0

    1 2

    1 6

    1 8

    2 0

    1 4

    4

    BS2F BS2F

    Gas Train

    MBDLE 403

    MBDLE 405

    MBC 65 DLE

    Code

    3970545

    3970546

    3970570

    Output

    45 kW *

    -

    -

    Gas Train

    MBDLE 405

    MBDLE 407

    Code

    3970547

    3970544

    * with natural gas.

    Plug and socket

    Plug and socket

    P

    combu

    stionhead+gastrain

    combu

    stionhead

    Pressureloss

    4

    1 0

    6

    8

    1 2

    kcal / h X 1000

    kW

    1 0 2 0 3 0 5 0

    2 0 6 0

    2

    0

    3 0 4 0 5 0

    14

    16

    4 0

    5216

    m

    bar

    4 4 , 71 3 , 8

    MBDLE

    405

    MBDLE

    403

    18

    20G25G20

    MBC

    65DL

    E

    P

    combu

    stionhead+gastrain

    combu

    stionhead

    Pressureloss

    4

    1 0

    6

    8

    12

    kcal / h X 1000

    kW

    1 0 2 0 3 0 5 0

    2 0 6 0

    2

    0

    3 0 4 0 5 0

    1 4

    1 6

    4 0

    5 216

    m

    bar

    4 4 , 71 3 , 8

    MBD

    LE405

    1 8

    2 0LPG

    MBD

    LE403

    MBC

    65 DL

    E

    P

    combustionhead+g

    astrain

    combustionhead

    Pressureloss

    4

    1 0

    6

    8

    1 2

    kcal / h X 1000

    2

    0

    1 4

    1 6mbar

    3 0 4 0 5 0 6 0 7 0 78 ,2

    MBDL

    E405

    MBDL

    E407

    kW

    6 04 0 5 0

    9135

    7 0 8 0 3 0

    G25G20

    P

    combustionhead+g

    astrain

    combustionhead

    Pressureloss

    4

    1 0

    6

    8

    1 2

    kcal / h X 1000

    2

    0

    1 4

    1 6mbar

    3 0 4 0 5 0 6 0 7 0 78 ,2

    MBD

    LE407

    kW

    604 0 5 0

    9135

    7 0 803 0

    LPG

    MBD

    LE405

    6

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    7/20

    MBD

    LE407

    0

    5

    1 5

    2 5

    3 0

    3 5

    2 0

    MBD

    LE40

    7

    0

    5

    2 5

    3 0

    2 0

    NATURAL GAS LPG

    BS3F BS3F

    BS4F BS4F

    note For pressure levels different from those indicated above, pleasecontact Riello Burners Technical Office.In LPG plants, Multibloc gas trains do not operate below 0C.They are only suitable for gaseous LPG (liquid hydrocarbons destroythe seal materials).

    Gas Train

    MBDLE 407

    MBDLE 410

    MBDLE 412

    Code

    3970548

    3970549

    3970550

    Output

    150 kW *

    -

    -

    * with natural gas.

    Gas Train

    MBDLE 407

    MBDLE 410

    MBDLE 412

    Code

    3970548

    3970549

    3970550

    Output

    150 kW *

    -

    -

    * with natural gas.

    Plug and socket

    Plug and socket

    combustionhead+gastrain

    combustionhead

    Pressureloss

    1 0

    5

    15

    kcal / h X 1000

    kW

    0

    7 0 8 0

    20

    30

    18 965

    m

    bar

    1 4 0

    5 5 ,9 7 0 8 0 9 0 1 0 0 1 1 0 1 20 1 3 0 1 40 1 5 0 1 6 2 ,5

    9 0 1 0 0 1 1 0 1 2 0 1 3 0 1 5 0 1 6 0 1 70 1 8 0

    2 5

    MBDL

    E410

    MBDL

    E412

    G20 G25

    P

    1 50

    P

    combustionhead+gastrain

    combustionhead

    Pressureloss

    10

    5

    1 5

    kcal / h X 1000

    kW

    0

    7 0 8 0

    2 0

    3 0

    1 896 5

    m

    bar

    14 0

    5 5 ,9 7 0 8 0 9 0 1 0 0 1 1 0 1 20 1 3 0 1 40 1 5 0 1 6 2 ,5

    9 0 1 0 0 1 1 0 1 2 0 1 3 0 1 5 0 1 6 0 1 8 0

    25

    MBDLE

    410

    LPG

    MBDLE

    407

    P

    combustionhead+gastrain

    combustionhead

    Pressureloss

    5

    1 0

    1 5

    kcal / h X 1000

    kW

    0

    2 0

    2 5

    24 6

    m

    bar

    14 0

    1 10

    1 2 0 1 6 0 1 8 0

    9 4 ,6 1 1 0 1 2 0 1 3 0 1 4 0 1 5 0 2 1 1 ,61 60 1 70 1 80 1 90 2 00

    2 00 2 2 0 2 4 0

    MBDL

    E410

    MBDL

    E412

    G20 G25

    P

    combustionhead+gastrain

    combustionhead

    Pressureloss

    5

    10

    15

    kcal / h X 1000

    kW

    0

    2 0

    2 5

    2 46

    m

    bar

    1 40

    11 0

    1 2 0 1 6 0 1 8 0

    9 4 ,6 1 1 0 1 2 0 1 3 0 1 4 0 1 5 0 2 1 1 ,61 60 1 70 1 80 1 90 2 00

    20 0 2 2 0 2 4 0

    MBDL

    E410

    LPG

    MBD

    LE407

    17 0

    MBDLE

    412

    MBDL

    E412

    1 0

    4 0

    1 0

    1 5

    7

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    8/20

    0 ,1 0 ,2 0 ,3 0 ,4 0 ,5 0,6 0,7 0,8 1 2 3 4 5 1 06 2 0

    5 0 6 0 1 0 08 0 2 0 0 4 0 0 8 0 0 1 0 0 06 0 0

    3

    6

    9

    1215

    2230

    45 61 76 95 122 152 V

    PRESSUREDROP(mbar)

    1 2 3 4 5 6 7 8 1 0 2 0 3 0 4 0

    PIPEDIAMETER

    1,4

    PIPELENGTH(m)

    1/2

    1"

    1"1/

    2

    6"

    1"1/

    4

    4"

    3"

    2"1/

    22"

    3/

    4

    =Gas output Nmc/ h

    f

    1 - G 20

    = 0 ,6 2 - G 2 5

    1,18 - G 31{

    f

    V

    15,34

    8

    SELECTING THE FUEL SUPPLY LINES

    The following diagram enables pressure drop in a pre-existing gas line to be calculated and to select thecorrect gas train.The diagram can also be used to select a new gas line when fuel output and pipe length are known. Thepipe diameter is selected on the basis of the desired pressure drop. The diagram uses methane gas asreference; if another gas is used, conversion coefficient and a simple formula (on the diagram) transform

    the gas output to a methane equivalent (refer to figure A). Please note that the gas train dimensions musttake into account the back pressure of the combustion chamber during operations.

    Control of the pressure drop in an existing gas line or selecting a new gas supply line.The methane output equivalent is determined by the formula fig. A on the diagram and the conversioncoefficient.

    Once the equivalent output has been determined on the delivery scale ( ), shown at the top of thediagram, move vertically downwards until you cross the line that represents the pipe diameter; at thispoint, move horizontally to the left until you meet the line that represents the pipe length.Once this point is established you can verify, by moving vertically downwards, the pipe pressure dropon the botton scale (mbar).By subtracting this value from the pressure measured on the gas meter, the correct pressure value willbe found for the choice of gas train.

    Example: - gas used G25- gas output 9.51 mc/h- pressure at the gas meter 20 mbar- gas line length 15 m- conversion coefficient 0.62 (see figure A)

    - equivalent methane output = 9.51 = 15.34 mc/h0.62

    - once the value of 15.34 has been identified on the output scale ( ), moving vertically downwards youcross the line that represents 1" 1/4 (the chosen diameter for the piping);

    - from this point, move horizontally to the left until you meet the line that represents the length of 15 mof the piping;

    - move vertically downwards to determine a value of 1.4 mbar in the pressure drop botton scale;

    - subtract the determined pressure drop from the meter pressure, the correct pressure level will be foundfor the choice of gas train;

    - correct pressure = ( 20-1.4 ) = 18.6 mbar

    V

    V

    V

    Figure A

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    9/20

    COMBUSTION HEAD

    VENTILATION

    The combustion head in Gulliver BSF burners is the result of an

    innovative design, which allows combustion with low pollutingemissions, while being easy to adapt to all the various types ofboilers and combustion chambers.

    Combustion head

    Air pressure switch

    Mobile flange

    The different ventilation circuits always ensure low noise levelswith high performance of pressure and air delivery, in spite of

    their compact size.

    Thanks to the use of a mobilecoupling flange, the penetration ofthe head into the combustionchamber can be adjusted.

    Simple adjustment allows theinterna l geometry of thecombustion head to be adapted tothe burner output.

    The burners are fitted with anadjustable air pressure switch,conforming to EN 676 standards.

    Dimensions of the flame

    Example:Burner thermal output= 350 kW;L flame(m) = 1,2 m (medium value);D flame(m) = 0,6 m (medium value)Burner output (kW)

    Flamelength(m)

    Flamediameter(m)

    0 200

    1

    100 300

    2

    400 500

    0 0

    0,5

    1

    D

    L

    Lmax

    Lmin

    Dmax

    Dmin

    9

    Air suction

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    10/20

    ADJUSTMENT

    All these models are one stage operation.

    BURNER OPERATION MODE

    Air damper adjustment

    Output

    CheckedVariable

    bar

    C

    ON

    OFF

    time

    time

    ON

    OFF

    One stageoperation

    All Gulliver BS series burners are fitted with a new microprocessor control panel for the supervisionduring intermittent operation.For helping the commissioning and maintenance work, there are two main elements:

    The lock-out reset button is the central operating elementfor resetting the burner controland for activating / deactivating the diagnostic functions.

    The multi-color LED is the central indication elementfor visual diagnosis and interfacediagnosis.

    Both elements are located under the transparent cover of lock-out reset button, as showed below.

    There are two diagnostic choices, for indication of operation and diagnosis of fault cause:

    - visual diagnosis:

    - interface diagnosis:by the interface adapter anda PC with dedicated

    software.

    Switch

    Switch

    COMPUTER

    INTERFACE ADAPTER

    10

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    11/20

    Indication of operation:In normal operation, the various statues areindicated in the form of colour codes accordingto the table below.

    Diagnosis of fault causes:After lock-out has occurred, the red signal lamp is steady on. In this status, the visual fault diagnosisaccording to the error code table can be activated by pressing the lock-out reset button for > 3 seconds.The control box sends a sequence of pulses that are repeated at 2-second intervals.The interface diagnosis (with adapter) can be activated by pressing again the lock-out button for > 3seconds.

    Example of blinks sequence:

    LED off2 sec. 2 sec. 2 sec.

    11

    Color code table

    Operation statues

    Stand-by

    Pre-purging

    Ignition phase

    Flame OK

    Post purgeUndervoltage, built-in fuse

    Fault, alarm

    Color code

    Led off

    Green

    Green

    Green

    Green

    Led off

    Red

    Error code table

    Possible cause of fault

    No flame at the end of safety time:- faulty or soiled gas valves- faulty ionisation probe- poor adjustment of burner, no gas- faulty ignition- neutral / phase exchange

    Air pressure switch does not close or is already closed before heat demand:- faulty air pressure switch- air pressure switch incorrectly regulated

    Presence of flame:- in stand-by position- with thermostat of heat demand in idle or working position

    - during pre-purge- during post-purge

    Loss of air pressure:- during pre-purge- during or after safety time

    Loss of flame during operations after n3 attempts of re-cycle:- faulty or soiled gas valves- faulty ionisation probe- short circuit between ionisation probe and earth of the burner- poor adjustment of burner, no fuel

    Blink code

    2 blinks

    3 blinks

    4 blinks

    6 blinks

    7 blinks

    The MG569 digital control box gives some other advantages:

    Post ignition (during safety time)The spark ignition is present during all safety time

    Adjustable post purgeThe Post-purge is a function that maintains air ventilation even after the burner is switched off.Post-purge time can be set to a maximum of 6 minutes.This function can be activated and set in a very easy way by pressing repeatedly the reset button;after 5 seconds the control box automatically shows the minutes set by the red LED flashing (1 pulse= post-ventilation for 1 minute).If during post-purge there is a new request for heat, it is halted and a new operating cycle starts.The control box leaves the factory with the setting 0 minutes (no post-ventilation).

    Remote lock-out resetThe Remote lock-out reset is a function that allows to reset the control-box operation from a remote

    position. In the burnerpackages will be included a

    particular connector toremote the reset signal.The maximum length ofconnection must be 20 m.

    Switch

    CONNECTOR

    Connection cable

    max 20 m

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    12/20

    Electrical connections must be madeby qualified and skilled personnelin conformity with the localregulations in force.

    WIRING DIAGRAMS

    ONE STAGE OPERATIONControl-box fitted with ignition transformer

    The following table shows thesupply lead sections and types offuse to be used.

    Gas train electrical wiring

    3 2 N Ph1

    P

    321

    VS V1

    321Black Grey

    Gas

    6-pole socket

    6-pin plug

    Correct operation0s Start of heat demand the burner begins the ignition cycle0s-4s The burner is in stand-by4s-44s Pre-purge with opened air damper44s Ignition.

    Lock-out due to ignition failureIf the flame does not light within the safety limit (~ 3s) the burner locks-out.

    Re-cycleThe burner permits maximum three repetitions of complete ignition cycle if there is flame failure duringoperation.The burner goes in safety shut-down within one second.The final action at the last trial following at last flame failure is a lock-out.

    START UP CYCLE

    (A)Lock-out is shown by a led on the appliance.(B)Total number of recycle trials is 3

    Time(s) Time(s)

    Thermostat

    M

    V1

    3 s

    Ignitiontransformer

    40 s

    1

    Lock-out

    Normal

    3 s40 s

    Lock-out dueto ignition failure (A)

    Time(s)

    3 s40 s

    Limited number of recycletrials (B)

    4s 4s 4s 3 s40 s4s

    h1 - One stage hours counter (230V 0,1A max)SB - Remote lock-out signal (230V 0,1A max)TL - Limit thermostatTS - Safety thermostat (manual reset)VS - Safety valveV1 - One stage valveP - Gas pressure switchF - Fuse

    F = FuseL = Lead section

    12

    BS1FModel

    A

    mm2

    F

    L

    220-230V

    T6

    1

    BS2F

    220-230V

    T6

    1

    BS3F

    220-230V

    T6

    1

    BS4F

    220-230V

    T6

    1

    Burner electrical wiring

    B4 S3T2 N L1T1

    F

    7-pole socket

    TSSB

    TL

    N L PE

    h1

    7-pin plug

    Main switch

    ~ 50/60Hz 220/230V

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    13/20

    EMISSIONS

    The emission data have beenmeasured in the various models atmaximum output, in conformitywith EN 676 standard.

    Special attention has been paidto noise reduction. All modelsare fitted with sound-proofing

    material inside the cover. Ino r d e r t o p r o t e c t t h ecomponents from environmentdust, special seals have beenfitted on the cover.

    BS4FBS3FBS2FBS1F

    BS4FBS3FBS2FBS1F

    NO2 EMISSIONS

    mg/kWh

    60

    CO EMISSIONS

    mg/kWh

    0

    5

    10

    15

    20

    SOUND EMISSIONS (sound pressure)

    dB(A)

    54

    56

    72

    62

    64

    66

    68

    70

    72

    74

    25

    58

    60

    62

    64

    66

    68

    70

    76

    BS1F BS2F BS3F BS4F

    The burners in the Gulliver BSF series guarantee controlled

    combustion, reducing emissions of both CO and NOx. Thiscombustion control is due to the recirculation of the combustionproducts in the chamber (thanks to different combustible airflow speeds) and to the fuel staging technique (thanks to thespecial geometry of the gas nozzles).

    13

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    14/20

    OVERALL DIMENSIONS (mm)

    These models are distinguished by their reduced size, in relationto the outputs achieved, which means they can be fitted toany boiler on the market.

    X

    Z

    Y

    PACKAGING

    BURNER-BOILER MOUNTING FLANGE

    Z

    340

    365

    430

    430

    Model

    BS1F

    BS2F

    BS3F

    BS4F

    X Y kg

    385

    395

    440

    500

    268

    288

    335

    335

    10

    11

    15

    16,5

    14

    F - F2E - E1

    H

    I

    L

    D

    B

    A

    C

    BURNER

    Model A B DC F

    BS1F

    BS2F

    BS3F

    BS4F

    122

    125,5

    150

    150

    234

    255

    300

    300

    70

    100

    110

    145

    112

    125,5

    150

    150

    295

    325

    391

    392

    E

    230

    238

    262

    271

    H

    89

    106

    129

    137

    I

    210

    230

    285

    286

    L

    41

    45

    45

    45

    116

    114

    128

    168

    F2E1

    276

    252

    280

    301

    Model QCA

    BS1F

    BS2F

    BS3F

    BS4F

    89

    106

    129

    137

    45

    45

    45

    45

    167

    167

    201

    203

    170

    170

    190

    200

    140

    140

    160

    170

    C1 C2 F O

    66

    66

    76,5

    80,5

    192

    192

    216

    218

    D

    89

    106

    129

    137

    R

    11

    11

    11

    11C2

    C1

    F

    C

    O

    R

    A - D

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    15/20

    INSTALLATION DESCRIPTION

    Installation, start up and maintenance must be carried out by qualifiedand skilled personnel.The burner is set in the factory on standard calibration (minimum

    output). If necessary adjustments can be made on the basis of themaximum output of the boiler. All operations must be performed asdescribed in the technical handbook supplied with the burner.

    Head setting is easy and aided by a graduated scale; a testpoint allows reading the air pressure in the combustionhead.

    The air damper position can be adjusted without removingthe burner cover.

    Gulliver BSF burners are fitted with an air pressure switchwhich, in accordance with EN 676 standards, can beadjusted by the installer using a graduated selector, onthe basis of the effective working conditions.

    The mobile flange allows adapting the length of thecombustion head to the combustion chamber (flameinversion or 3 smoke cycles) and to the thickness of theboiler panel.

    BURNER SETTING

    Maintenance is easily solved because the combustionhead can be disassembled without having to remove theburner and gas train from the boiler.

    MAINTENANCE AND ELECTRICAL CONNECTIONS

    15

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    16/20

    BURNER ACCESSORIES

    16

    Extended head kitStandard head burners can be transformed into extended head versions by using the special kit.Below the kits available for the various burners are listed, showing the original and the extended lengths.

    Kit code

    BS2F (long)

    BS2F (extra long)

    BS3FBS4F

    Burner

    Extended head kit

    Extended headlength (mm)

    170 180

    270 280

    267 282302 317

    Standard headlength (mm)

    100 114

    100 114

    110 128145 168

    3001007

    3001008

    30010093001016

    The 7-pole socket is incorporated in the control box, the6-pole socket for connection to the gas train is alreadyconnected to the equipment and fixed to the outside ofthe burner.The 7-pin plug is also supplied for connection to the boiler.

    LPG kitFor burning LPG gas, a special kit is available to be fitted to the combustion head on the burner, asshown in the following table:

    3001003

    3001004

    3001005

    3001011

    BS1F

    BS2F

    BS3F

    BS4F

    Burner

    LPG kit

    -

    3001004

    3001005

    3001011

    Kit code forextended head

    Kit code forstandard head

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    17/20

    Kit code

    3002731BS1F - BS2F - BS3F - BS4F

    Burner

    Interface adapter kit

    17

    Alternative combustion head kitTo extend the adaptability of Gulliver BSF burners to any sort of application, alternative combustionheads have been developed, for example, to overcome situations of combustion instability whichcould arise with certain heat generators.These heads cause a very limited increase in NOx emissions, due to the slow air flow.

    Kit code

    3001059

    3001064

    3001060

    3001070

    BS1F

    BS2F

    BS3F

    BS4F

    Burner

    Alternative combustion head kit

    Kit code

    3000945BS1F - BS2F - BS3F - BS4F

    Burner

    7-pin plug kit

    7-pin plug kitIf necessary a 7-pin plug kit is available (in packaging of n. 5 pieces).

    Kit code

    3001180BS1F - BS2F - BS3F - BS4F

    Burner

    Ground fault interrupter kit

    A ground fault interrupter kit is available as safety device in case of electrical system fault.

    Ground fault interrupter kit

    Multibloc rotation kitThere is a special kit available that can be used to install the burner turned 180. This kit is designed toensure the gas train valve properly. (see the section entitled "3.2 Operating position" in the instruction book).

    BS1F

    BS2F

    BS3F - BS4F

    Burner

    Multibloc rotation kit

    3001179

    3001177

    3001178

    Kit code

    Interface adapter kitTo connect the flame control panel to a personal computer for the transmission of operation, faultsignals and detailed service information, an interface adapter with PC software are available.

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    18/20

    SPECIFICATION

    A special index guides your choice of boiler from thevarious models available in the BSF series.

    Below there is a clear and detailed specificationdescription of the product.

    Size

    Fuel : S Natural gasSP LPGG Light oil

    DESIGNATION OF SERIES

    B S 3

    Series: R Standard emission burnerB Low NOx burners

    Optional variations: F Light industrial processes

    AVAILABLE BURNER MODELS

    BS1F 1/220-230/50-60BS2F 1/220-230/50-60BS3F 1/220-230/50-60BS4F 1/220-230/50-60

    Electrical supply to the system: 1/220-230/50-60 1/220-230V/50-60Hz

    1/230/50F

    Seal control kitTo test the valve seals on the gas train, (except for the model with Multibloc MBC 65 DLE) a special"seal control kit" is available.

    Seal control kit

    Kit code

    BS1F

    BS2F

    BS3F

    BS4F

    Burner

    3010123

    3010123

    3010123

    3010123

    MBDLE 403 - 405

    MBDLE 405 - 407

    MBDLE 407 - 410 - 412

    MBDLE 407 - 410 - 412

    Gas Train

    GAS TRAIN ACCESSORIES

    18

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf

    19/20

    Burner:

    Monobloc, gas burners, completely automatic, with one stage operation fitted with:- Fan with forward curve blades- Cover lined with sound-proofing material- Air damper always open in stand by, with external adjustment, with no need to remove the cover- Single phase electric motor 220 - 230 V/50 - 60 Hz- Combustion head fitted with:

    - stainless steel head cone, resistant to high temperatures- ignition electrodes- ionisation probe- gas distributor- flame stability disk

    - Flame inspection window- Adjustable air pressure switch, with graduated selector, to guarantee burner lock out in the case of insufficient combustible air

    - Microprocessor-based flame control panel, with diagnostic and remote reset functions- Protection filter against radio interference (included into flame control panel)- IP X0D (IP 40) electric protection level.

    Gas train:

    Fuel supply line in the Multibloc configuration, fitted with:- Filter- Pressure stabiliser- Minimum gas pressure switch- Safety valve- One stage working valve with ignition gas output regulator.

    Approval:- EN 676 Standard- EN 746-2 Standard (for the part of the working field that is depressurised).

    Conforming to European Directives:- 90/396/EEC (gas)- 73/23/EEC (low voltage)- 89/336/EEC (electromagnetic compatibility).

    Conforming to:- BlmSchV 1996.

    Standard equipment:- Flange with insulating gasket- Screw and nut for flange- Screw and nuts for flange to be fixed to the heat generator- 7-pin plug- Remote control release kit- Instruction handbook for installation, use and maintenance- Spare parts catalogue.

    Available accessories to be ordered separately:- Extended head kit- LPG kit- Alternative combustion head kit

    - Ground fault interrupter kit- Multibloc rotation kit- 7-pin plug kit- Interface adapter kit- Seal control kit.

    PRODUCT SPECIFICATION

    19

  • 8/10/2019 Gulliver BSF_TS0059UK01.pdf