The Riello Gulliver BSF series of one stage gas burners, is a complete range of productsdeveloped to respond to any request for light industrial processes like bakery ovens, spraypainting ovens, small steam or thermal boilers and all applications which require a reliable,user-friendly industrial product with enhanced performance and specific functions.The Gulliver BSF series is available in four different models, with an output ranging from16 to 246 kW, divided in four different structures.All the models use the same components designed by Riello for the Gulliver series andhave the same ventilation system and overall dimensions as the previous one stage gasmodels. The Gulliver BSF burners are fitted with a microprocessor - based flame controlpanel, with diagnostic functions.This new series can operates on 50 or 60 Hz and a Voltage 220 - 230 Volt (dual frequency).
All these burners are conform to the EN 676 Standard (Forced draught gas burners) and toEuropean Directives for EMC, Low Voltage and Gas Appliance. For depressurised workingfield see EN 746-2 Standard.All the Gulliver BSF burners are fired before leaving the factory.
TS0059UK01
LOW NOx ONE STAGE GAS BURNERSGULLIVER BSF SERIES BS1F 16 52 kW
BS2F 35 91 kW
BS3F 65 189 kW
BS4F 110 246 kW
8/10/2019 Gulliver BSF_TS0059UK01.pdf
2/20
TECHNICAL DATA
Approval
F
uel/airdata
Electricaldata
Emissions
BS1F BS2F BS3F BS4F
One stage
--
--
--
16 - 52 35 - 91 65 - 189 110 - 246
13,8 - 44,7 30,1 - 78,2 55,9 - 162,5 94,6 - 211,6
0/40
10
0,71
1,6 - 5,2 3,5 - 9,1 6,5 - 18,9 11 - 24,6
8,6
0,78
1,9 - 6 4,1 - 10,6 7,6 - 22 12,8 - 28,6
25,8
2,020,6 - 2 1,4 - 3,5 2,5 - 7,3 4,3 - 9,5
Centrifugal with forward curve blades
40
1/50 - 60/220 - 230 10%
--
MG 569
0,135(at 50 Hz) - 0,165(at 60 Hz) 0,155(at 50 Hz) - 0,200(at 60 Hz)0,355(at 50 Hz) - 0,485(at 60 Hz)0,420(at 50 Hz) - 0,600(at 60 Hz)
--
X0D
0,09 0,09 0,15 0,25
0,6(at 50 Hz) - 0,75(at 60 Hz) 0,7(at 50 Hz) - 0,9(at 60 Hz) 1,6(at 50 Hz) - 2,2(at 60 Hz) 1,9(at 50 Hz) - 2,7(at 60 Hz)
2,4(at 50 Hz) - 3(at 60 Hz) 2,8(at 50 Hz) - 3,6(at 60 Hz) 6,4(at 50 Hz) - 8,8(at 60 Hz) 7,6(at 50 Hz) - 10,8(at 60 Hz)
20
Incorporated in the control box
230 V - 8 kV
0,2 A - 12 mA
Intermittent (at least one stop every 24 h)
61 62 66 71
--
20 10 20 10
75 70 75 65
90/396/EEC, 89/336/EEC, 73/23/EEC
EN 676 - EN 746-2
In progress
type
s
kW
Mcal/h
C min./max.
kWh/Nm3
kg/Nm3
Nm3/h
kWh/Nm3
kg/Nm3
Nm3/h
kWh/Nm3
kg/Nm3
Nm3/h
type
max C
Ph/Hz/V
Ph/Hz/V
type
kW
kW
IP
kW
A
A
IP
type
V1 - V2
I1 - I2
dB (A)
W
mg/kWh
mg/kWh
Model
Burner operation mode
Modulation ratio at max. output
Servomotorrun time
Heat output
Working temperature
Net calorific value G20 gas
G20 gas density
G20 gas delivery
Net calorific value G25 gas
G25 gas density
G25 gas delivery
Net calorific value LPG gas
LPG gas densityLPG gas delivery
Fan
Air temperature
Electrical supply
Auxiliary electrical supply
Control box
Total electrical power
Auxiliary electrical power
Protection level
Motor electrical power
Rated motor current
Motor start up current
Motor protection level
Ignition transformer
Operation
Sound pressure
Sound power
CO emission
NOx emission
Directive
Conforming to
Certification
Reference conditions:
Temperature: 20C
Pressure: 1013 mbar
Altitude: 0 m a.s.l.
Noise measured at a distance of 1 meter.
Since the Company is constantly engaged in the production improvement, the aesthetic and dimensional features,the technical data, the equipment and the accessories can be changed.This document contains confidential and proprietary information of RIELLO S.p.A. Unless authorised, this informationshall not be divulged, nor duplicated in whole or in part.
2
8/10/2019 Gulliver BSF_TS0059UK01.pdf
3/203
FIRING RATES
35
0
5
10
15
20
25
30
-20
-15
-10
-5
45
40
50
0
0,5
Mcal/h
1,0
1,5
2,0
2,5
3,0
3,5
232,2206,4180,6154,8129,0103,251,625,80
-0,5
-1,0
-1,5
-2,0
77,4
4,0
4,5
5,0
kW27024021018015012060300 90
BS3F
hPa(mbar)
mmH2O
BS1F
BS2F
BS4F
Test conditions conforming to EN 676:
Temperature: 20 C
Pressure: 1013 mbar
Altitude: 0 m a.s.l.
Useful working field for choosing the burner
IMPORTANT: For the part of the working field that is depressurised, refer to EN 746-2 Standard.
8/10/2019 Gulliver BSF_TS0059UK01.pdf
4/20
The burners are set for fuel supply from either the right orleft hand sides.
Depending on the fuel output and the available pressure inthe supply line, you should check the correct gas train tobe adapted to the system requirements.
The gas train is Multibloc type, containing the maincomponents in a single unit.Except for the MBC 65 DLE model, a valve seal control (asaccessory) can be fitted to the Multibloc gas trains.
The MBC 65 DLE Multibloc gas train can be fitted only tothe left of the burner.
GAS TRAIN
FUEL SUPPLY
Gas train installed on the burner
MBDLE 403 - 405 - 407 - 410 - 412
L1 L
LEAK DETECTION CONTROL DEVICE
MULTIBLOC
5
9
6
7 8
12
3
4
P2
10
12
P1
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
P1
P2
P3
L
L1
Gas delivery pipe
Manual valve
Vibration damping joint
Gas pressure gauge
Filter
Gas pressure switch
Safety solenoid
Adjustment solenoid:
firing delivery adjustment (rapid opening)
maximum delivery adjustment (slow opening)
Pressure regulator
Leak detection control device for valves 7 and 8 (accessory)
Gas train-burner adapter
Burner
Shutter with adjustment screws
Pressure regulator setting device
Regulation solenoid
Combustion head pressure
Upstream pressure from the filter
Upstream pressure from the control valve
Gas train supplied separately
To be performed by the installer
MBC 65 DLE
L1 L
MULTIBLOC
5
6
7 15
12
3
4
P2
12
P1
P3
13
13
14
9 11
11
4
8/10/2019 Gulliver BSF_TS0059UK01.pdf
5/20
MULTIBLOC
NameMBC 65 DLE
MBDLE 403
MBDLE 405
MBDLE 405
MBDLE 407
MBDLE 407
MBDLE 410
MBDLE 412
Code
3970570
3970545
3970546
3970547
3970544
3970548
3970549
3970550
i
1/2"
1/2"
1/2"
3/4"
3/4"
3/4"
1" 1/4
1" 1/4
o
FLANGE 1
FLANGE 1
FLANGE 1
FLANGE 2
FLANGE 2
FLANGE 3
FLANGE 3
FLANGE 3
X mm
232
200
246
236
236
236
259
259
Y mm
126
137
186
186
186
186
215
215
Z mm
122
100
120
120
120
120
145
145
W mm
45
45
45
47
47
47
47
47
V mm
31
26
46
46
46
46
55
55
mbar max*
65
300
300
300
300
300
300
300
* max inlet gas pressure (mbar)
Y
Z X
Y
Z X
i
W
W
V
V
The dimensions of the gas trains vary depending on their construction features.The following table shows the dimensions of the gas trains that can be fitted to Gulliver BSF burners,intake diameter and the coupling flange to the burner.
5
i o
o
8/10/2019 Gulliver BSF_TS0059UK01.pdf
6/20
PRESSURE DROP DIAGRAM
The diagrams indicate the minimum pressure drop of the burners with the various gas trains thatcan be combined with them; the value thus calculated represents the minimum required input
pressure to the gas train.
NATURAL GAS LPG
BS1F BS1F
10
12
18
0
2
6
8
16
26
14
4
20
24
22
0
2
6
8
1 0
1 2
1 6
1 8
2 0
1 4
4
BS2F BS2F
Gas Train
MBDLE 403
MBDLE 405
MBC 65 DLE
Code
3970545
3970546
3970570
Output
45 kW *
-
-
Gas Train
MBDLE 405
MBDLE 407
Code
3970547
3970544
* with natural gas.
Plug and socket
Plug and socket
P
combu
stionhead+gastrain
combu
stionhead
Pressureloss
4
1 0
6
8
1 2
kcal / h X 1000
kW
1 0 2 0 3 0 5 0
2 0 6 0
2
0
3 0 4 0 5 0
14
16
4 0
5216
m
bar
4 4 , 71 3 , 8
MBDLE
405
MBDLE
403
18
20G25G20
MBC
65DL
E
P
combu
stionhead+gastrain
combu
stionhead
Pressureloss
4
1 0
6
8
12
kcal / h X 1000
kW
1 0 2 0 3 0 5 0
2 0 6 0
2
0
3 0 4 0 5 0
1 4
1 6
4 0
5 216
m
bar
4 4 , 71 3 , 8
MBD
LE405
1 8
2 0LPG
MBD
LE403
MBC
65 DL
E
P
combustionhead+g
astrain
combustionhead
Pressureloss
4
1 0
6
8
1 2
kcal / h X 1000
2
0
1 4
1 6mbar
3 0 4 0 5 0 6 0 7 0 78 ,2
MBDL
E405
MBDL
E407
kW
6 04 0 5 0
9135
7 0 8 0 3 0
G25G20
P
combustionhead+g
astrain
combustionhead
Pressureloss
4
1 0
6
8
1 2
kcal / h X 1000
2
0
1 4
1 6mbar
3 0 4 0 5 0 6 0 7 0 78 ,2
MBD
LE407
kW
604 0 5 0
9135
7 0 803 0
LPG
MBD
LE405
6
8/10/2019 Gulliver BSF_TS0059UK01.pdf
7/20
MBD
LE407
0
5
1 5
2 5
3 0
3 5
2 0
MBD
LE40
7
0
5
2 5
3 0
2 0
NATURAL GAS LPG
BS3F BS3F
BS4F BS4F
note For pressure levels different from those indicated above, pleasecontact Riello Burners Technical Office.In LPG plants, Multibloc gas trains do not operate below 0C.They are only suitable for gaseous LPG (liquid hydrocarbons destroythe seal materials).
Gas Train
MBDLE 407
MBDLE 410
MBDLE 412
Code
3970548
3970549
3970550
Output
150 kW *
-
-
* with natural gas.
Gas Train
MBDLE 407
MBDLE 410
MBDLE 412
Code
3970548
3970549
3970550
Output
150 kW *
-
-
* with natural gas.
Plug and socket
Plug and socket
combustionhead+gastrain
combustionhead
Pressureloss
1 0
5
15
kcal / h X 1000
kW
0
7 0 8 0
20
30
18 965
m
bar
1 4 0
5 5 ,9 7 0 8 0 9 0 1 0 0 1 1 0 1 20 1 3 0 1 40 1 5 0 1 6 2 ,5
9 0 1 0 0 1 1 0 1 2 0 1 3 0 1 5 0 1 6 0 1 70 1 8 0
2 5
MBDL
E410
MBDL
E412
G20 G25
P
1 50
P
combustionhead+gastrain
combustionhead
Pressureloss
10
5
1 5
kcal / h X 1000
kW
0
7 0 8 0
2 0
3 0
1 896 5
m
bar
14 0
5 5 ,9 7 0 8 0 9 0 1 0 0 1 1 0 1 20 1 3 0 1 40 1 5 0 1 6 2 ,5
9 0 1 0 0 1 1 0 1 2 0 1 3 0 1 5 0 1 6 0 1 8 0
25
MBDLE
410
LPG
MBDLE
407
P
combustionhead+gastrain
combustionhead
Pressureloss
5
1 0
1 5
kcal / h X 1000
kW
0
2 0
2 5
24 6
m
bar
14 0
1 10
1 2 0 1 6 0 1 8 0
9 4 ,6 1 1 0 1 2 0 1 3 0 1 4 0 1 5 0 2 1 1 ,61 60 1 70 1 80 1 90 2 00
2 00 2 2 0 2 4 0
MBDL
E410
MBDL
E412
G20 G25
P
combustionhead+gastrain
combustionhead
Pressureloss
5
10
15
kcal / h X 1000
kW
0
2 0
2 5
2 46
m
bar
1 40
11 0
1 2 0 1 6 0 1 8 0
9 4 ,6 1 1 0 1 2 0 1 3 0 1 4 0 1 5 0 2 1 1 ,61 60 1 70 1 80 1 90 2 00
20 0 2 2 0 2 4 0
MBDL
E410
LPG
MBD
LE407
17 0
MBDLE
412
MBDL
E412
1 0
4 0
1 0
1 5
7
8/10/2019 Gulliver BSF_TS0059UK01.pdf
8/20
0 ,1 0 ,2 0 ,3 0 ,4 0 ,5 0,6 0,7 0,8 1 2 3 4 5 1 06 2 0
5 0 6 0 1 0 08 0 2 0 0 4 0 0 8 0 0 1 0 0 06 0 0
3
6
9
1215
2230
45 61 76 95 122 152 V
PRESSUREDROP(mbar)
1 2 3 4 5 6 7 8 1 0 2 0 3 0 4 0
PIPEDIAMETER
1,4
PIPELENGTH(m)
1/2
1"
1"1/
2
6"
1"1/
4
4"
3"
2"1/
22"
3/
4
=Gas output Nmc/ h
f
1 - G 20
= 0 ,6 2 - G 2 5
1,18 - G 31{
f
V
15,34
8
SELECTING THE FUEL SUPPLY LINES
The following diagram enables pressure drop in a pre-existing gas line to be calculated and to select thecorrect gas train.The diagram can also be used to select a new gas line when fuel output and pipe length are known. Thepipe diameter is selected on the basis of the desired pressure drop. The diagram uses methane gas asreference; if another gas is used, conversion coefficient and a simple formula (on the diagram) transform
the gas output to a methane equivalent (refer to figure A). Please note that the gas train dimensions musttake into account the back pressure of the combustion chamber during operations.
Control of the pressure drop in an existing gas line or selecting a new gas supply line.The methane output equivalent is determined by the formula fig. A on the diagram and the conversioncoefficient.
Once the equivalent output has been determined on the delivery scale ( ), shown at the top of thediagram, move vertically downwards until you cross the line that represents the pipe diameter; at thispoint, move horizontally to the left until you meet the line that represents the pipe length.Once this point is established you can verify, by moving vertically downwards, the pipe pressure dropon the botton scale (mbar).By subtracting this value from the pressure measured on the gas meter, the correct pressure value willbe found for the choice of gas train.
Example: - gas used G25- gas output 9.51 mc/h- pressure at the gas meter 20 mbar- gas line length 15 m- conversion coefficient 0.62 (see figure A)
- equivalent methane output = 9.51 = 15.34 mc/h0.62
- once the value of 15.34 has been identified on the output scale ( ), moving vertically downwards youcross the line that represents 1" 1/4 (the chosen diameter for the piping);
- from this point, move horizontally to the left until you meet the line that represents the length of 15 mof the piping;
- move vertically downwards to determine a value of 1.4 mbar in the pressure drop botton scale;
- subtract the determined pressure drop from the meter pressure, the correct pressure level will be foundfor the choice of gas train;
- correct pressure = ( 20-1.4 ) = 18.6 mbar
V
V
V
Figure A
8/10/2019 Gulliver BSF_TS0059UK01.pdf
9/20
COMBUSTION HEAD
VENTILATION
The combustion head in Gulliver BSF burners is the result of an
innovative design, which allows combustion with low pollutingemissions, while being easy to adapt to all the various types ofboilers and combustion chambers.
Combustion head
Air pressure switch
Mobile flange
The different ventilation circuits always ensure low noise levelswith high performance of pressure and air delivery, in spite of
their compact size.
Thanks to the use of a mobilecoupling flange, the penetration ofthe head into the combustionchamber can be adjusted.
Simple adjustment allows theinterna l geometry of thecombustion head to be adapted tothe burner output.
The burners are fitted with anadjustable air pressure switch,conforming to EN 676 standards.
Dimensions of the flame
Example:Burner thermal output= 350 kW;L flame(m) = 1,2 m (medium value);D flame(m) = 0,6 m (medium value)Burner output (kW)
Flamelength(m)
Flamediameter(m)
0 200
1
100 300
2
400 500
0 0
0,5
1
D
L
Lmax
Lmin
Dmax
Dmin
9
Air suction
8/10/2019 Gulliver BSF_TS0059UK01.pdf
10/20
ADJUSTMENT
All these models are one stage operation.
BURNER OPERATION MODE
Air damper adjustment
Output
CheckedVariable
bar
C
ON
OFF
time
time
ON
OFF
One stageoperation
All Gulliver BS series burners are fitted with a new microprocessor control panel for the supervisionduring intermittent operation.For helping the commissioning and maintenance work, there are two main elements:
The lock-out reset button is the central operating elementfor resetting the burner controland for activating / deactivating the diagnostic functions.
The multi-color LED is the central indication elementfor visual diagnosis and interfacediagnosis.
Both elements are located under the transparent cover of lock-out reset button, as showed below.
There are two diagnostic choices, for indication of operation and diagnosis of fault cause:
- visual diagnosis:
- interface diagnosis:by the interface adapter anda PC with dedicated
software.
Switch
Switch
COMPUTER
INTERFACE ADAPTER
10
8/10/2019 Gulliver BSF_TS0059UK01.pdf
11/20
Indication of operation:In normal operation, the various statues areindicated in the form of colour codes accordingto the table below.
Diagnosis of fault causes:After lock-out has occurred, the red signal lamp is steady on. In this status, the visual fault diagnosisaccording to the error code table can be activated by pressing the lock-out reset button for > 3 seconds.The control box sends a sequence of pulses that are repeated at 2-second intervals.The interface diagnosis (with adapter) can be activated by pressing again the lock-out button for > 3seconds.
Example of blinks sequence:
LED off2 sec. 2 sec. 2 sec.
11
Color code table
Operation statues
Stand-by
Pre-purging
Ignition phase
Flame OK
Post purgeUndervoltage, built-in fuse
Fault, alarm
Color code
Led off
Green
Green
Green
Green
Led off
Red
Error code table
Possible cause of fault
No flame at the end of safety time:- faulty or soiled gas valves- faulty ionisation probe- poor adjustment of burner, no gas- faulty ignition- neutral / phase exchange
Air pressure switch does not close or is already closed before heat demand:- faulty air pressure switch- air pressure switch incorrectly regulated
Presence of flame:- in stand-by position- with thermostat of heat demand in idle or working position
- during pre-purge- during post-purge
Loss of air pressure:- during pre-purge- during or after safety time
Loss of flame during operations after n3 attempts of re-cycle:- faulty or soiled gas valves- faulty ionisation probe- short circuit between ionisation probe and earth of the burner- poor adjustment of burner, no fuel
Blink code
2 blinks
3 blinks
4 blinks
6 blinks
7 blinks
The MG569 digital control box gives some other advantages:
Post ignition (during safety time)The spark ignition is present during all safety time
Adjustable post purgeThe Post-purge is a function that maintains air ventilation even after the burner is switched off.Post-purge time can be set to a maximum of 6 minutes.This function can be activated and set in a very easy way by pressing repeatedly the reset button;after 5 seconds the control box automatically shows the minutes set by the red LED flashing (1 pulse= post-ventilation for 1 minute).If during post-purge there is a new request for heat, it is halted and a new operating cycle starts.The control box leaves the factory with the setting 0 minutes (no post-ventilation).
Remote lock-out resetThe Remote lock-out reset is a function that allows to reset the control-box operation from a remote
position. In the burnerpackages will be included a
particular connector toremote the reset signal.The maximum length ofconnection must be 20 m.
Switch
CONNECTOR
Connection cable
max 20 m
8/10/2019 Gulliver BSF_TS0059UK01.pdf
12/20
Electrical connections must be madeby qualified and skilled personnelin conformity with the localregulations in force.
WIRING DIAGRAMS
ONE STAGE OPERATIONControl-box fitted with ignition transformer
The following table shows thesupply lead sections and types offuse to be used.
Gas train electrical wiring
3 2 N Ph1
P
321
VS V1
321Black Grey
Gas
6-pole socket
6-pin plug
Correct operation0s Start of heat demand the burner begins the ignition cycle0s-4s The burner is in stand-by4s-44s Pre-purge with opened air damper44s Ignition.
Lock-out due to ignition failureIf the flame does not light within the safety limit (~ 3s) the burner locks-out.
Re-cycleThe burner permits maximum three repetitions of complete ignition cycle if there is flame failure duringoperation.The burner goes in safety shut-down within one second.The final action at the last trial following at last flame failure is a lock-out.
START UP CYCLE
(A)Lock-out is shown by a led on the appliance.(B)Total number of recycle trials is 3
Time(s) Time(s)
Thermostat
M
V1
3 s
Ignitiontransformer
40 s
1
Lock-out
Normal
3 s40 s
Lock-out dueto ignition failure (A)
Time(s)
3 s40 s
Limited number of recycletrials (B)
4s 4s 4s 3 s40 s4s
h1 - One stage hours counter (230V 0,1A max)SB - Remote lock-out signal (230V 0,1A max)TL - Limit thermostatTS - Safety thermostat (manual reset)VS - Safety valveV1 - One stage valveP - Gas pressure switchF - Fuse
F = FuseL = Lead section
12
BS1FModel
A
mm2
F
L
220-230V
T6
1
BS2F
220-230V
T6
1
BS3F
220-230V
T6
1
BS4F
220-230V
T6
1
Burner electrical wiring
B4 S3T2 N L1T1
F
7-pole socket
TSSB
TL
N L PE
h1
7-pin plug
Main switch
~ 50/60Hz 220/230V
8/10/2019 Gulliver BSF_TS0059UK01.pdf
13/20
EMISSIONS
The emission data have beenmeasured in the various models atmaximum output, in conformitywith EN 676 standard.
Special attention has been paidto noise reduction. All modelsare fitted with sound-proofing
material inside the cover. Ino r d e r t o p r o t e c t t h ecomponents from environmentdust, special seals have beenfitted on the cover.
BS4FBS3FBS2FBS1F
BS4FBS3FBS2FBS1F
NO2 EMISSIONS
mg/kWh
60
CO EMISSIONS
mg/kWh
0
5
10
15
20
SOUND EMISSIONS (sound pressure)
dB(A)
54
56
72
62
64
66
68
70
72
74
25
58
60
62
64
66
68
70
76
BS1F BS2F BS3F BS4F
The burners in the Gulliver BSF series guarantee controlled
combustion, reducing emissions of both CO and NOx. Thiscombustion control is due to the recirculation of the combustionproducts in the chamber (thanks to different combustible airflow speeds) and to the fuel staging technique (thanks to thespecial geometry of the gas nozzles).
13
8/10/2019 Gulliver BSF_TS0059UK01.pdf
14/20
OVERALL DIMENSIONS (mm)
These models are distinguished by their reduced size, in relationto the outputs achieved, which means they can be fitted toany boiler on the market.
X
Z
Y
PACKAGING
BURNER-BOILER MOUNTING FLANGE
Z
340
365
430
430
Model
BS1F
BS2F
BS3F
BS4F
X Y kg
385
395
440
500
268
288
335
335
10
11
15
16,5
14
F - F2E - E1
H
I
L
D
B
A
C
BURNER
Model A B DC F
BS1F
BS2F
BS3F
BS4F
122
125,5
150
150
234
255
300
300
70
100
110
145
112
125,5
150
150
295
325
391
392
E
230
238
262
271
H
89
106
129
137
I
210
230
285
286
L
41
45
45
45
116
114
128
168
F2E1
276
252
280
301
Model QCA
BS1F
BS2F
BS3F
BS4F
89
106
129
137
45
45
45
45
167
167
201
203
170
170
190
200
140
140
160
170
C1 C2 F O
66
66
76,5
80,5
192
192
216
218
D
89
106
129
137
R
11
11
11
11C2
C1
F
C
O
R
A - D
8/10/2019 Gulliver BSF_TS0059UK01.pdf
15/20
INSTALLATION DESCRIPTION
Installation, start up and maintenance must be carried out by qualifiedand skilled personnel.The burner is set in the factory on standard calibration (minimum
output). If necessary adjustments can be made on the basis of themaximum output of the boiler. All operations must be performed asdescribed in the technical handbook supplied with the burner.
Head setting is easy and aided by a graduated scale; a testpoint allows reading the air pressure in the combustionhead.
The air damper position can be adjusted without removingthe burner cover.
Gulliver BSF burners are fitted with an air pressure switchwhich, in accordance with EN 676 standards, can beadjusted by the installer using a graduated selector, onthe basis of the effective working conditions.
The mobile flange allows adapting the length of thecombustion head to the combustion chamber (flameinversion or 3 smoke cycles) and to the thickness of theboiler panel.
BURNER SETTING
Maintenance is easily solved because the combustionhead can be disassembled without having to remove theburner and gas train from the boiler.
MAINTENANCE AND ELECTRICAL CONNECTIONS
15
8/10/2019 Gulliver BSF_TS0059UK01.pdf
16/20
BURNER ACCESSORIES
16
Extended head kitStandard head burners can be transformed into extended head versions by using the special kit.Below the kits available for the various burners are listed, showing the original and the extended lengths.
Kit code
BS2F (long)
BS2F (extra long)
BS3FBS4F
Burner
Extended head kit
Extended headlength (mm)
170 180
270 280
267 282302 317
Standard headlength (mm)
100 114
100 114
110 128145 168
3001007
3001008
30010093001016
The 7-pole socket is incorporated in the control box, the6-pole socket for connection to the gas train is alreadyconnected to the equipment and fixed to the outside ofthe burner.The 7-pin plug is also supplied for connection to the boiler.
LPG kitFor burning LPG gas, a special kit is available to be fitted to the combustion head on the burner, asshown in the following table:
3001003
3001004
3001005
3001011
BS1F
BS2F
BS3F
BS4F
Burner
LPG kit
-
3001004
3001005
3001011
Kit code forextended head
Kit code forstandard head
8/10/2019 Gulliver BSF_TS0059UK01.pdf
17/20
Kit code
3002731BS1F - BS2F - BS3F - BS4F
Burner
Interface adapter kit
17
Alternative combustion head kitTo extend the adaptability of Gulliver BSF burners to any sort of application, alternative combustionheads have been developed, for example, to overcome situations of combustion instability whichcould arise with certain heat generators.These heads cause a very limited increase in NOx emissions, due to the slow air flow.
Kit code
3001059
3001064
3001060
3001070
BS1F
BS2F
BS3F
BS4F
Burner
Alternative combustion head kit
Kit code
3000945BS1F - BS2F - BS3F - BS4F
Burner
7-pin plug kit
7-pin plug kitIf necessary a 7-pin plug kit is available (in packaging of n. 5 pieces).
Kit code
3001180BS1F - BS2F - BS3F - BS4F
Burner
Ground fault interrupter kit
A ground fault interrupter kit is available as safety device in case of electrical system fault.
Ground fault interrupter kit
Multibloc rotation kitThere is a special kit available that can be used to install the burner turned 180. This kit is designed toensure the gas train valve properly. (see the section entitled "3.2 Operating position" in the instruction book).
BS1F
BS2F
BS3F - BS4F
Burner
Multibloc rotation kit
3001179
3001177
3001178
Kit code
Interface adapter kitTo connect the flame control panel to a personal computer for the transmission of operation, faultsignals and detailed service information, an interface adapter with PC software are available.
8/10/2019 Gulliver BSF_TS0059UK01.pdf
18/20
SPECIFICATION
A special index guides your choice of boiler from thevarious models available in the BSF series.
Below there is a clear and detailed specificationdescription of the product.
Size
Fuel : S Natural gasSP LPGG Light oil
DESIGNATION OF SERIES
B S 3
Series: R Standard emission burnerB Low NOx burners
Optional variations: F Light industrial processes
AVAILABLE BURNER MODELS
BS1F 1/220-230/50-60BS2F 1/220-230/50-60BS3F 1/220-230/50-60BS4F 1/220-230/50-60
Electrical supply to the system: 1/220-230/50-60 1/220-230V/50-60Hz
1/230/50F
Seal control kitTo test the valve seals on the gas train, (except for the model with Multibloc MBC 65 DLE) a special"seal control kit" is available.
Seal control kit
Kit code
BS1F
BS2F
BS3F
BS4F
Burner
3010123
3010123
3010123
3010123
MBDLE 403 - 405
MBDLE 405 - 407
MBDLE 407 - 410 - 412
MBDLE 407 - 410 - 412
Gas Train
GAS TRAIN ACCESSORIES
18
8/10/2019 Gulliver BSF_TS0059UK01.pdf
19/20
Burner:
Monobloc, gas burners, completely automatic, with one stage operation fitted with:- Fan with forward curve blades- Cover lined with sound-proofing material- Air damper always open in stand by, with external adjustment, with no need to remove the cover- Single phase electric motor 220 - 230 V/50 - 60 Hz- Combustion head fitted with:
- stainless steel head cone, resistant to high temperatures- ignition electrodes- ionisation probe- gas distributor- flame stability disk
- Flame inspection window- Adjustable air pressure switch, with graduated selector, to guarantee burner lock out in the case of insufficient combustible air
- Microprocessor-based flame control panel, with diagnostic and remote reset functions- Protection filter against radio interference (included into flame control panel)- IP X0D (IP 40) electric protection level.
Gas train:
Fuel supply line in the Multibloc configuration, fitted with:- Filter- Pressure stabiliser- Minimum gas pressure switch- Safety valve- One stage working valve with ignition gas output regulator.
Approval:- EN 676 Standard- EN 746-2 Standard (for the part of the working field that is depressurised).
Conforming to European Directives:- 90/396/EEC (gas)- 73/23/EEC (low voltage)- 89/336/EEC (electromagnetic compatibility).
Conforming to:- BlmSchV 1996.
Standard equipment:- Flange with insulating gasket- Screw and nut for flange- Screw and nuts for flange to be fixed to the heat generator- 7-pin plug- Remote control release kit- Instruction handbook for installation, use and maintenance- Spare parts catalogue.
Available accessories to be ordered separately:- Extended head kit- LPG kit- Alternative combustion head kit
- Ground fault interrupter kit- Multibloc rotation kit- 7-pin plug kit- Interface adapter kit- Seal control kit.
PRODUCT SPECIFICATION
19
8/10/2019 Gulliver BSF_TS0059UK01.pdf