Installation Instructions Original Instructions GuardLink Enabled Tap Catalog Numbers 440S-SF5D, 440S-SF8D, 440S-MF5D, 440S-MF8D, 440S-MLF8D, 440S-SLF8D Figure 1 - Dimensions [mm (in.)] Figure 2 - Status Indicators Mounting Information Link In/Out Connection Device Connection IMPORTANT Electronic equipment. Handle with care, do not drop. A 24V DC Class 2 power source is required for all GuardLink® enabled taps. Cat. Nos. 440S-MLF8D and 440S-SLF8D are the only GuardLink enabled taps that support Power to Lock guard locking devices. IMPORTANT Do not over torque the mounting hardware. Attribute Value Recommended fastener size M5 Mounting hardware torque 2.20 N•m (19.95 in•lb) Connector torque Finger tighten the cordset connections and then tighten an additional 1/4- to 1/2-turn with pliers. 57 (2.24) 79.64 (3.13) Ø5.4 (0.21) 17 (0.67) 38.5 (1.51) INPUT M12 x 1 thread J1 J3 J2 Device Status Indicator Link Status Indicator To Device Link Out Link In Table 1 - J1 — 4-pin Micro M12 Male (Link In) Pin No. Wire Color Function Pinouts 1 Brown 24V DC 2 White GuardLink Safety 3 Blue GND 4 Black GuardLink CLU Table 2 - J2 — 4-pin Micro M12 Female (Link Out) Pin No. Wire Color Function Pinouts 1 Brown 24V DC 2 White GuardLink Safety 3 Blue GND 4 Black GuardLink CLU Table 3 - J3 — 5-pin Micro M12 Female Pin No. Wire Color Cat. No. Pinout 440S-MF5D 440S-SF5D EMSS OSSD 1 Brown Safety Contact A 24V DC 2 White Safety OSSD Channel A Input 3 Blue GND GND 4 Black Safety Contact B Safety OSSD Channel B Input 5 Gray J1 4 3 1 2 J2 3 2 1 4 J3 5 4 3 1 2

GuardLink Enabled Tap Installation Instructions

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: GuardLink Enabled Tap Installation Instructions

Installation InstructionsOriginal Instructions

GuardLink Enabled TapCatalog Numbers 440S-SF5D, 440S-SF8D, 440S-MF5D, 440S-MF8D, 440S-MLF8D, 440S-SLF8D

Figure 1 - Dimensions [mm (in.)]

Figure 2 - Status Indicators

Mounting Information

Link In/Out Connection

Device Connection

IMPORTANT • Electronic equipment. Handle with care, do not drop.• A 24V DC Class 2 power source is required for all

GuardLink® enabled taps.• Cat. Nos. 440S-MLF8D and 440S-SLF8D are the only

GuardLink enabled taps that support Power to Lock guard locking devices.

IMPORTANT Do not over torque the mounting hardware.

Attribute Value

Recommended fastener size M5Mounting hardware torque 2.20 N•m (19.95 in•lb)

Connector torque Finger tighten the cordset connections and then tighten an additional 1/4- to 1/2-turn with pliers.

57 (2.24)

79.64 (3.13)

Ø5.4 (0.21)

17(0.67)

38.5 (1.51)

INPUT

M12 x 1 thread

J1

J3

J2

Device Status Indicator

Link Status Indicator

To Device

Link OutLink In

Table 1 - J1 — 4-pin Micro M12 Male (Link In)

Pin No. Wire Color Function Pinouts1 Brown 24V DC2 White GuardLink Safety3 Blue GND

4 Black GuardLink CLU

Table 2 - J2 — 4-pin Micro M12 Female (Link Out)

Pin No. Wire Color Function Pinouts1 Brown 24V DC2 White GuardLink Safety3 Blue GND

4 Black GuardLink CLU

Table 3 - J3 — 5-pin Micro M12 Female

Pin No. Wire Color

Cat. No.Pinout440S-MF5D 440S-SF5D

EMSS OSSD1 Brown

Safety Contact A24V DC

2 White Safety OSSD Channel A Input

3 Blue GND GND

4 BlackSafety Contact B

Safety OSSD Channel B Input

5 Gray —

J1

431

2

J2

3

21

4

J3

5

4

3

1

2

Page 2: GuardLink Enabled Tap Installation Instructions

Optional Mounting BracketFigure 3 - 440S-GLTAPBRK1 Dimensions [mm (in.)]

Additional ResourcesThese documents contain additional information concerning related products from Rockwell Automation.

You can view or download publications at rok.auto/literature.

Table 4 - J3 — 8-pin Micro M12 Female

Pin No.

Wire Color (1)

(1) Wire colors apply to the Type B cordset.

Cat. No. (2)

(2) Cat. Nos. 440S-MLF8D and 440S-SLF8D are the only GuardLink enabled taps that support Power to Lock guard locking devices.

Pinout440S-MF8D440S-MLF8D

440S-SF8D440S-SLF8D

EMSS OSSD1 White — Auxiliary Input2 Brown Lock/Unlock 24V DC3 Green — Lock/Unlock

4 Yellow Safety Contact B Safety OSSD Channel B+ (24V DC)

5 Gray Safety Contact A Safety OSSD Channel A Input

6 Pink Safety Contact B Safety OSSD Channel B Input

7 Blue GND GND

8 Red Safety Contact A Safety OSSD Channel A+ (24V DC)

J3

5

67

84

3

12

Resource Description

Guardmaster GuardLink Safety System User Manual, publication 440R-UM015

Provides guidelines for installing a Guardmaster® GuardLink Safety System.

Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1

Provides general guidelines for installing a Rockwell Automation industrial system.

Product Certifications website,rok.auto/certifications

Provides declarations of conformity, certificates, and other certification details.

6 x Ø5.4 (0.21) for M5 screws(Ø11 (0.43) max screw head)

22(0.87)

11(0.43)20

(0.79)

38.5(1.51)

76.6 (3.01)

19.6(0.77)

25(0.98)

Publication 440S-IN007D-EN-P - October 2020 | Supersedes Publication 440S-IN007C-EN-P - February 2019Copyright © 2020 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.

Rockwell Otomasyon Ticaret A.Ş. Kar Plaza İş Merkezi E Blok Kat:6 34752, İçerenköy, İstanbul, Tel: +90 (216) 5698400 EEE Yönetmeliğine Uygundur

Allen-Bradley, expanding human possibility, GuardLink, Guardmaster, and Rockwell Automation are trademarks of Rockwell Automation, Inc.Trademarks not belonging to Rockwell Automation are property of their respective companies.

Your comments help us serve your documentation needs better. If you have any suggestions on how to improve our content, complete the form at rok.auto/docfeedback.For technical support, visit rok.auto/support.

*PN-606273*PN-606273

PN-60627310005788263 Ver 00

Waste Electrical and Electronic Equipment (WEEE)

Rockwell Automation maintains current product environmental compliance information on its website at rok.auto/pec.

At the end of life, this equipment should be collected separately from any unsorted municipal waste.

Page 3: GuardLink Enabled Tap Installation Instructions

CONFIDENTIAL AND PROPRIETARY INFORMATION. THIS DOCUMENT CONTAINS CONFIDENTIAL AND PROPRIETARY INFORMATION OF

ROCKWELL AUTOMATION, INC. AND MAY NOT BE USED, COPIED OR DISCLOSED TO OTHERS, EXCEPT WITH THE AUTHORIZED WRITTEN

PERMISSION OF ROCKWELL AUTOMATION, INC.

Sheet

Size Ver

Of 11

A 01Dr. DateG. USHAKOW 3-21-13

SPECIFICATIONS FOR1 OR 2 PAGE INSTRUCTION SHEET4-1/4” W x 5-1/2” H - FINAL FOLD

MATERIALSIZE

FOLD

BODY STOCK WHITEBODY INK BLACK

FLAT

8-1/2" W x 11" H 4-1/4" W x 5-1/2" H

10000021654

Final Fold

4-1/4”

5-1/2”

11”

8-1/2”

Note: After folding---Printed in (Country where printed*), part number(s) and barcode (when used) should be visible.

* The printing vendor may change the instruction sheet files to show the correct country.

PN-123456DIR 10000000000 (Version 00)Printed in U.S.A.

BARCODE