Global Array Manager™Server Software

Installation Guide andUser Manual

Part Number 775078-00 08P3299

© Copyright 2000 Mylex Corporation.All Rights Reserved.

All contents of this manual are copyrighted by Mylex Corporation. The information contained herein is the exclusive property of Mylex Corporation and shall not be copied, transferred, photocopied, translated on paper, film, electronic media, or computer-readable form; or otherwise reproduced in any way, without the express written permission of Mylex Corporation.

GreetingsThis manual describes the Mylex Global Array Manager Server Software.

Requests for technical information about this and other Mylex Corporation products should be made to your Mylex authorized reseller or Mylex marketing representative.

Please NoticeIBM, Mylex, DAC960, DAC1100, Global Array Manager, GAM, RAID EzAssist, AcceleRAID, and eXtremeRAID are trademarks or registered trademarks of International Business Machines Corp. and its subsidiaries. MS-DOS, Windows 95, Windows 98, Windows NT, and Windows 2000 are registered trademarks of Microsoft Corporation. Novell and NetWare are registered trademarks of Novell, Inc. SCO, SCO UNIX, and UnixWare are registered trademarks of The Santa Cruz Operation, Ltd. Solaris is a registered trademark of Sun Microsystems, Inc. Linux is written and distributed under the GNU General Public License which means that its source code is freely-distributed and available to the general public. SuSE is a trademark of SuSE Incorporated. Caldera is a trademark of Caldera Systems Incorporated. Red Hat is a registered trademark of Redhat Incorporated. Other names that are trademarks may be used herein for the purpose of identifying the products or services of their respective owners.

Unless otherwise noted, companies, names and data used in examples herein are fictitious.

Our PolicyAlthough reasonable efforts have been made to assure the accuracy of the information contained herein, this publication could include technical inaccuracies or typographical errors. Mylex Corporation expressly disclaims liability for any error in this information, and for damages, whether direct, indirect, special, exemplary, consequential or otherwise, that may result from such error, including but not limited to loss of profits resulting from the use or misuse of the manual or information contained therein (even if Mylex Corporation has been advised of the possibility of such damages). Any questions or comments regarding this document or its contents should be addressed to Mylex Corporation at the address shown on the cover.

The following paragraph does not apply to the United Kingdom or any country where such provisions are inconsistent with local law:

MYLEX CORPORATION PROVIDES THIS PUBLICATION “AS IS” WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.

Some states do not allow disclaimer of express or implied warranties or the limitation or exclusion of liability for indirect, special, exemplary, incidental or consequential damages in certain transactions; therefore, this statement may not apply to you. Also, you may have other rights which vary from jurisdiction to jurisdiction.

Information in this publication is subject to change without notice and does not represent a commitment on the part of Mylex Corporation. Changes may be made periodically to the information herein; these changes will be incorporated in new editions of the publication. Mylex Corporation reserves the right to make improvements and/or changes at any time in the product(s) and/or program(s) described in this publication.

It is possible that this publication may contain reference to, or information about, Mylex Corporation products (machines and programs), programming or services that are not announced in your country. Such references or information must not be construed to mean that Mylex Corporation intends to announce, provide, or make available such Mylex products, programming, or services in your jurisdiction.

About This ManualThis installation guide covers the steps involved to install and use the Mylex Global Array Manager Server Software.

In addition, this document covers installation and use of SNMP, RAID Fault Management, External RAID support enabling, use of the mylexdrv.siz file, and GAM Event Logging.

For information on defining and setting RAID (Redundant Array of Independent Disks) levels as well as configuration of the array, consult the Global Array Manager Client manual and the RAID EzAssist Configuration Utility Quick Configuration Guide or User Reference Guide.

Conventions

Throughout the manual, the following conventions are used to describe user interaction with the product:

bold The user must enter the bold text exactly as shown

↵ Press the Enter key

Enter Press the key labeled “Enter” (or “Delete”, etc.)

File, Run Select the Run option from the pull-down menu activated when the File menu pad is selected

� NoteSupplementary information that can have an effect on system performance

� CautionNotification that a proscribed action has the potential to adversely affect equipment operation, system performance, or data integrity

� WARNINGNotification that a proscribed action will definitely result in equipment damage, data loss, or personal injury

2345678

NetWare

Windows NT

Windows 2000

SCO OpenServer

UnixWare

Solaris

Linux

Appendixes

vi Global Array Manager Server Software Manual

Contents

Chapter 1Introduction

Overview ........................................................................................... 1-1Global Array Manager Server Overview ............................................ 1-2

Monitoring Functions .................................................................. 1-2SNMP/DMI Support ............................................................ 1-2

Management Functions .............................................................. 1-2Configuration Functions ............................................................. 1-2

Requirements .................................................................................... 1-3Server Hardware and Software – NetWare ................................ 1-3Server Hardware and Software – Windows NT .......................... 1-4Server Hardware and Software – Windows 2000 ...................... 1-4Server Hardware and Software – SCO OpenServer .................. 1-4Server Hardware and Software – UnixWare .............................. 1-4Server Hardware and Software – Solaris 7 on x86 .................... 1-5Server Hardware and Software – Linux ..................................... 1-5

Chapter 2NetWare

Overview ........................................................................................... 2-1Global Array Manager Server Software for NetWare 5.0 and 4.2 ..... 2-2

Installing Global Array Manager Server Software ...................... 2-2Running Global Array Manager Server ...................................... 2-4

Loading Global Array Manager Server Manually ................ 2-4Loading Global Array Manager Server Automatically ......... 2-4Enabling the Event Comment Line ..................................... 2-4

Troubleshooting Server Software Installation ............................. 2-5

Windows NTOverview ........................................................................................... 3-1Global Array Manager Server Software for Windows NT 4.0 ............ 3-2

Installation Overview .................................................................. 3-2File List ....................................................................................... 3-2Installing Global Array Manager Server Software ...................... 3-3Running Global Array Manager Server .................................... 3-20Troubleshooting Server Software Installation ........................... 3-20

DMI Manual Configuration ............................................................... 3-21DMI Files .................................................................................. 3-21

Manual No. 775078 vii

Chapter 3Windows 2000

Overview ............................................................................................ 4-1Global Array Manager Server Software for Windows 2000 ............... 4-2

Installation Overview ..................................................................4-2File List ....................................................................................... 4-2Installing Global Array Manager Server Software ...................... 4-3Running Global Array Manager Server ....................................4-20Troubleshooting Server Software Installation ...........................4-20

DMI Manual Configuration ...............................................................4-21DMI Files ..................................................................................4-21

Chapter 4SCO OpenServer

Overview ............................................................................................ 5-1Global Array Manager Server Software for SCO OpenServer 5.0.5 .5-2

Creating the Global Array Manager Server Diskette .................. 5-2Installing Global Array Manager Server Software ...................... 5-2Running Global Array Manager Server ......................................5-4Troubleshooting Server Software Installation ............................. 5-4Uninstalling the Server Software ................................................ 5-4

Chapter 5UnixWare

Overview ............................................................................................ 6-1Global Array Manager Server Software for UnixWare 7.x, 2.1.2, and 2.1.3 .......................................................................................... 6-2

Creating the Global Array Manager Server Diskette .................. 6-2Installing Global Array Manager Server Software ...................... 6-2Running Global Array Manager Server ......................................6-4Troubleshooting Server Software Installation ............................. 6-4Uninstalling the Server Software ................................................ 6-5

Chapter 6Solaris

Overview ............................................................................................ 7-1Global Array Manager Server Software for Solaris 7.0 ...................... 7-2

Creating the Global Array Manager Server Diskette .................. 7-2Installing Global Array Manager Server Software ...................... 7-2Running Global Array Manager Server ......................................7-5Troubleshooting Server Software Installation ............................. 7-6Uninstalling the Server Software ................................................ 7-6

viii Global Array Manager Server Software Manual

Chapter 7Linux

Overview ........................................................................................... 8-1Global Array Manager Server Software for Linux .............................. 8-2

Installation Overview .................................................................. 8-2Installing Global Array Manager Server Software ...................... 8-2Running Global Array Manager Server ...................................... 8-3Troubleshooting Server Software Installation ............................. 8-4Uninstalling the Server Software ................................................ 8-5

Appendix ASNMP Installation, Operation, and Definition

Introduction ........................................................................................A-1SNMP Installation Overview ..............................................................A-1SNMP Installation for NetWare ..........................................................A-1

Starting the NetWare Agent .......................................................A-2SNMP Installation for Windows NT or Windows 2000 .......................A-3

Install the SNMP Agent ..............................................................A-3MIB Compilation and Definition File Creation ....................................A-3MYLEXRAIDMIB Object Definitions ..................................................A-4

Traps ..........................................................................................A-4Controller Information Group ......................................................A-8Logical Drive Information Group ..............................................A-15Physical Device Information Group ..........................................A-17RAID Management Software Group ........................................A-20Logical Drive Statistics Group ..................................................A-21Physical Drive Statistics Group ................................................A-22Fault Management Cabinet Information Group ........................A-23RAID Event Information Group ................................................A-25Battery Backup Unit Information Group ...................................A-27

Appendix BRAID Fault Management

RAIDBUILD Utility Overview ..............................................................B-1RAIDBLD Command Line ..................................................................B-1Enabling and Running RAID Fault Management (RAIDBLD) ............B-2

RAIDBLD Command Line Parameters .......................................B-3Running RAIDBLD .....................................................................B-5

Manual No. 775078 ix

Appendix CExternal RAID Support Enabling

External RAID Support Enabling Overview ...................................... C-1GAMCONFG Command Line ........................................................... C-1Enabling External RAID Support (GAMCONFG) .............................. C-2

GAMCONFG Command Line Parameters ................................ C-2Running GAMCONFG ............................................................... C-5

Appendix DThe MYLEXDRV.SIZ File

Drive Size Limits Overview ............................................................... D-1GAMSETSZ Command Line ............................................................. D-2Using the MYLEXDRV.SIZ File ........................................................ D-3

MYLEXDRV.SIZ Byte Definitions .............................................. D-3

Appendix EGAMEVENT

Introduction ........................................................................................E-1NetWare ............................................................................................E-2

Enabling Event Notification ........................................................E-2Enabling a GAM Event Log File .................................................E-3Saving and Restarting ................................................................E-3

Windows NT and Windows 2000 .......................................................E-4Enabling Event Notification ........................................................E-4Enabling a GAM Event Log File .................................................E-5Saving and Restarting ................................................................E-5

SCO UNIX and UnixWare ..................................................................E-6Enabling Event Notification ........................................................E-6Enabling a GAM Event Log File .................................................E-7Saving and Restarting ................................................................E-7

Solaris ................................................................................................E-8Enabling Event Notification ........................................................E-8Enabling a GAM Event Log File .................................................E-9Saving and Restarting ................................................................E-9

Linux ................................................................................................E-10Enabling Event Notification ......................................................E-10Enable GAM Event Logging .....................................................E-11Saving and Restarting ..............................................................E-12

Additional GAMEVENT Parameters ................................................E-12GAMEVENT LOG Options ...............................................................E-13

x Global Array Manager Server Software Manual

Chapter 1Introduction

OverviewThis manual describes information on how to install the Global Array Manager (GAM) Server software for several supported operating systems.

This chapter describes:

• GAM Server functions

• GAM Server requirements under supported operating systems.

Global Array Manager Server software is delivered on the CD-ROM. It is used to install GAM Server software on a server running a particular network operating system.

� NoteThis manual assumes that the network administrator will be performing any of the installation procedures described herein.

� NoteIn order to use SCO UNIX, UnixWare, or Solaris, you will need to create a diskette by downloading the driver files from the CD-ROM to a new diskette.

Open the file directory on your CD-ROM to access the list of driver file names.

Manual No. 775078 1-1

Global Array Manager Server Overview

Global Array Manager Server OverviewGlobal Array Manager Server Software is used to manage disk array subsystems attached to a Mylex Disk Array Controller.

Monitoring Functions

The Global Array Manager Server software collects and disseminates information on disk array status and resource utilization. The Global Array Manager Client software organizes this information through an intuitive graphical display. GAM Server monitors the characteristics and performance of supported Mylex Disk Array Controllers.

SNMP/DMI Support

The Global Array Manager Server software includes SNMP and DMI support, allowing stand-alone monitoring of performance and fault information. This is useful if a management package is already in use. Support for these protocols includes “read only” functions. Write functions are only available through use of the optional Global Array Manager Client software.

Management FunctionsThe Global Array Manager Server software executes the management instructions specified by the Global Array Manager Client. GAM Server software offers fault management, reliable messaging, and superior operating system support. Global Array Manager Client software manages or performs maintenance on individual disk arrays and drives (with the appropriate authentication), again by means of the graphical user interface.

Configuration FunctionsDisk array configuration and remote TCP/IP support functions are provided through use of the Global Array Manager Client software. If your goal is monitoring and simple maintenance or messaging, Global Array Manager Server is sufficient for these tasks.

1-2 Global Array Manager Server Software Manual

Introduction

RequirementsThe following information provides the hardware and software requirements for the Global Array Manager Server software under several network operating systems.

It is assumed that the hardware installation, the system configuration, and the disk array controller configuration are properly completed. If not, please see the Mylex PCI Disk Array Controller Drivers Installation Guide and User Manual, and the RAID EzAssist Configuration Utility User Reference Guide or Quick Configuration Guide. Complete the required procedures described in those manuals before proceeding with installation of GAM Server discussed herein.

The person who will be performing the installation must have Administrator access for the system onto which GAM Server will be installed.

Before starting, be sure to read through all applicable instructions to determine the specific requirements for this installation.

The correct environment must be present on the server for the Global Array Manager Server software to work properly. The environment is a combination of hardware and software which meets the following requirements:

Server Hardware and Software – NetWare

• A server running Novell NetWare 4.2 or 5.0 on x86

• 1 MB of free system memory after all volumes are mounted

• 2 MB of free hard disk space on the SYS: volume

• Properly installed and configured Mylex Disk Array Controller with the appropriate NetWare drivers

• (Optional) If SNMP participation is desired, SNMP support (available from third parties) should be installed.

• TCP/IP must be installed

Manual No. 775078 1-3

Requirements

Server Hardware and Software – Windows NT

• A server running Microsoft Windows NT 4.0 Workstation, Server or Enterprise edition on x86 with SP4 or SP5 installed

• 2 MB of free hard disk space

• Properly installed and configured Mylex Disk Array Controller with the appropriate Windows NT drivers

• TCP/IP must be installed

Server Hardware and Software – Windows 2000

• A server running Microsoft Windows 2000 on x86 Professional, Server, or Advanced Server

• 2 MB of free hard disk space

• Properly installed and configured Mylex Disk Array Controller with the appropriate Windows 2000 drivers

• (Optional) If SNMP participation is desired, SNMP support (available from third parties) should be installed.

• TCP/IP must be installed

Server Hardware and Software – SCO OpenServer

• A server running SCO OpenServer (version 5.05)

• 2 MB of free hard disk space

• Properly installed and configured Mylex Disk Array Controller with the appropriate SCO UNIX drivers

• TCP/IP must be installed

Server Hardware and Software – UnixWare

• A server running UnixWare (version 7.x on x86, 2.2.1 and 2.1.3)

• 2 MB of free hard disk space

• Properly installed and configured Mylex Disk Array Controller with the appropriate UnixWare drivers

• TCP/IP must be installed

1-4 Global Array Manager Server Software Manual

Introduction

Server Hardware and Software – Solaris 7 on x86

• A server running Solaris 7 on x86

• 2 MB of free hard disk space

• Properly installed and configured Mylex Disk Array Controller with the appropriate Solaris drivers or Sun MLX driver

• TCP/IP must be installed

Server Hardware and Software – Linux

• A server running Linux version:

• Red Hat 6.2

• SuSe 6.4

• Caldera 2.4

• Turbo Linux 6.0

• 1 MB of free system memory after all volumes are mounted

• 2 MB of free hard disk space

• TCP/IP must be installed

• Inetd must be running

• SNMP (Optional)

• GAM Client software (Only compatible with Windows NT, 2000, 98, and 95)

Manual No. 775078 1-5

Requirements

1-6 Global Array Manager Server Software Manual

NETWA

Chapter 2NetWare

2RE

Overview This chapter describes installation, verification, and startup of the Global Array Manager Server software for Novell NetWare. The software is provided on the CD-ROM.

� NoteThis chapter assumes that the network administrator for this site will be performing these installation procedures.

Manual No. 775078 2-1

Global Array Manager Server Software for NetWare 5.0 and 4.2

Global Array Manager Server Software for NetWare 5.0 and 4.2

Installing Global Array Manager Server Software

The Global Array Manager (GAM) Server software for NetWare has an automated installation utility which is run from the NetWare server console. This utility places the Global Array Manager Server application in the correct server directory and modifies the NetWare startup file, AUTOEXEC.NCF, to launch the application when the server is started.

� NoteThese instructions assume that your CD-ROM drive is properly identified and that CDROM.NLM is loaded.

Follow the steps below to install the GAM server software. Note the difference between NetWare 5.0 and NetWare 4.2 for the first step.

1. If you are using NetWare 5.0, simply insert the Software Kit distribution CD-ROM into the file server’s CD-ROM drive; the mount function is automatic. Skip to Step 2.

If you are using NetWare 4.2, to mount the Software Kit distribution CD-ROM, type the following command at the server console prompt (:).

CD MOUNT ALL

Make a written note of the volume label that will appear at the end of the messages that appear during the load process. You will need to use the volume label later in the installation.

2. At the console, type the following command and press <Enter> to run the installation.

: <Volume Label>:gam\netware\install

� NoteDo not type any extension. Type only ....\install.Replace <Volume Label> with the actual volume label of the Software Kit distribution CD-ROM.

2-2 Global Array Manager Server Software Manual

NetWare

2NETWARE

3. The Global Array Manager Server software installation screen appears.

• To install the GAM Server software, select Install.

• To cancel the installation, select Exit.

As the software is installed, the server’s AUTOEXEC.NCF file is updated to start the Global Array Manager Server application whenever the server runs this file.

4. Press the <Enter> key at the Update AUTOEXEC.NCF message.

5. Installation is complete. Edit AUTOEXEC.NCF as follows:

• Modify the GAMEVENT and GAMEVLOG lines manually. Change the GAMEVENT line to include (after each -h parameter) the IP addresses of the client systems you will use to record events. Modify the pathname and filename in the GAMEVLOG command line if you wish to. Refer to Appendix E, GAMEVENT, for information.

• If you wish to enable RAID Fault Management (RAIDBUILD) and optionally change its default parameters, you need to modify the RAIDBLD command line installed in AUTOEXEC.NCF. Refer to Appendix B, RAID Fault Management, for information.

• If you will be using drives from more than one vendor in the same RAID Group, refer to Appendix D, The MYLEXDRV.SIZ File, for information on setting drive size limits for consistency across multiple vendors’ drives.

6. Be sure to remove comment markers (such as the character #) from any command line which you intend to enable.

7. Save the modified AUTOEXEC.NCF and exit.

8. Create a user account called gamroot. Assign administrator rights to that user account.

9. To load the GAM server components, see “Loading Global Array Manager Server Manually” on page 2-4 after verifying correct server software installation.

Manual No. 775078 2-3

Global Array Manager Server Software for NetWare 5.0 and 4.2

Running Global Array Manager Server

The Global Array Manager Server runs on the server and performs the following functions:

• Monitors the controller(s) and disks in the server.

• Manages the controller(s) and associated disk subsystems in the server.

• Sends information to Global Array Manager Clients (if used).

Loading Global Array Manager Server Manually

The Global Array Manager Server can be loaded manually from the NetWare server console prompt (:). Type the following two commands:

load gamserv ↵

load gamevent -h <IP Address or Name of Client>(repeat...)

Loading Global Array Manager Server Automatically

The Global Array Manager Server can be custom-made to start up automatically on a NetWare server, when the NetWare server is restarted after installation of Global Array Manager. This capability will be available because the following two files will be automatically copied into AUTOEXEC.NCF, at the end of the file, during the GAM installation.

load gamserv

load gamevent -h <IP Address or Name of Client>(repeat...)

Remember that you will need to edit the IP address line. See Enabling the Event Comment Line in the next section to add an IP address line, as needed.

Enabling the Event Comment Line

To enable event notification to GAM Clients, both local and remote, add “-h DNS_NAME” or “-h IP_NUMBER” to the end of the “load gamevent” line for each GAM Client and uncomment the line. DNS_NAME and IP_NUMBER are the workstation’s Computer Name or IP Address. You can add up to 50 clients.

Usage:

load gamevent -h <IP Address or Name of Client>(repeat...)

2-4 Global Array Manager Server Software Manual

NetWare

2NETWARE

Troubleshooting Server Software Installation

Problem: The message “Error in connecting selected server” is displayed or an error is encountered when trying to connect to a server.

Check: Is the IP address correct?

Check: Is the server software, GAMSERV.NLM, installed and loaded on the server(s)? Use the following NetWare console command to verify that the GAMSERV module is loaded:

modules GAMSERV ↵

Check: Is the Ethernet connection good?

Check: Is TCP/IP set up correctly? Try Ping to find the server.

Problem: Global Array Manager Server will not load.

Check: Is the installation complete? The files GAMSERV.NLM, GAMDRV.NLM, and GAMEVENT.NLM should be contained in the SYS:SYSTEM directory of the server.

Manual No. 775078 2-5

Global Array Manager Server Software for NetWare 5.0 and 4.2

2-6 Global Array Manager Server Software Manual

Chapter 3Windows NT

3WINNT

OverviewThis chapter describes installation, verification, and startup of the Global Array Manager (GAM) Server software for Microsoft Windows NT 4.0 (SP4 or SP5). The software is provided on the Software Kit CD-ROM.

� NoteThis chapter assumes that the network administrator for this site will be performing these installation procedures.

Manual No. 775078 3-1

Global Array Manager Server Software for Windows NT 4.0

Global Array Manager Server Software for Windows NT 4.0

Installation Overview

Installation of the Global Array Manager Server component requires the Windows NT operating system. It will not work on a Windows 95 or Windows 98 operating system.

Reminder: This chapter assumes that the network administrator for this site will be performing these installation procedures.

You may also choose to install GAM Client at the same time on the same system. Refer to the appropriate Global Array Manager Client Software Installation Guide and User Manual for GAM Client installation instructions.

File List

Global Array Manager software is shipped on an accompanying distribution CD-ROM. The file list (and path) is as follows (where X: represents the drive letter of your CD-ROM drive):

X:\GAM\WINNT\

_INST32I.EX_ DATA.TAG SETUP.EXE_ISDEL.EXE DATA1.CAB SETUP.INI_SETUP.DLL DATA1.HDR SETUP.INS_SYS1.CAB LANG.DAT SETUP.LID_SYS1.HDR LAYOUT.BIN_USER1.CAB OS.DAT_USER1.HDR

3-2 Global Array Manager Server Software Manual

Windows NT

3WINNT

Installing Global Array Manager Server Software

Follow the steps below to install GAM Server software for Windows NT 4.0.

1. Make sure TCP/IP is installed and functioning properly.

2. Insert the Software Kit CD-ROM into your CD-ROM drive.

AutoRun will cause the CD-ROM to display the Mylex RAID Management Software Installation menu (Figure 3-1).

Figure 3-1. Mylex RAID Management Software Installation Menu

3. Click on the option called “Install Global Array Manager.” This option is used to install GAM Server.

Global Array Manager Setup loads the installation wizard (Figure 3-2).

Figure 3-2. Loading the Installation Wizard

Manual No. 775078 3-3

Global Array Manager Server Software for Windows NT 4.0

4. After a few moments, the Welcome dialog box appears (Figure 3-3). Click Next to proceed with the installation, or click Cancel to end the installation procedure and return to the menu.

Figure 3-3. Welcome Dialog Box

5. When the Mylex Software License Agreement screen appears, click Yes to accept the terms of the agreement and continue.

If you click No, you will not be allowed to continue GAM Server installation.

3-4 Global Array Manager Server Software Manual

Windows NT

3WINNT

The Select Components dialog box is displayed as shown in Figure 3-4. At this point you will select the component(s) you wish to install.

Figure 3-4. Select Components to Install

6. To select Global Array Manager Server for installation, click the box to check the Global Array Manager Server option.

� NoteYou may also choose to install Global Array Manager Client at this time. If you wish to install both GAM Server and GAM Client, please refer to the appropriate Global Array Manager Client Installation Guide and User Manual to install the Global Array Manager Client.

Manual No. 775078 3-5

Global Array Manager Server Software for Windows NT 4.0

7. When you select and highlight the Global Array Manager Server option, the Change button becomes active so that you can access the Select Sub-components screen.

If you do not wish to change the subcomponents, click Next and proceed to Step 10 on page 3-7, OR

Click Change to see the Select Sub-components screen (Figure 3-5). Driver and Program Files should remain selected. DMI and SNMP may be selected or deselected as needed:

• If you select DMI, Setup copies the DMI files to the server directory, but it does not configure the DMI files. Please refer to “DMI Manual Configuration” on page 3-21.

• If you select SNMP, the SNMP files are copied to the server directory and configured automatically. For more information about SNMP support in Mylex products, please refer to Appendix A.

Figure 3-5. Sub-Components List

3-6 Global Array Manager Server Software Manual

Windows NT

3WINNT

8. Make your subcomponent selections, then click Continue to return to the “Select Components” dialog box, Figure 3-4.

9. Click Next from the “Select Components” dialog box to continue with the installation.

10. Special Conditions: GAM Server Installation

#1: If you have attempted to install Workstation Array Manager, you will see the following message (Figure 3-6).

Figure 3-6. Error – Must Choose GAM Server OR WSAM

Click OK to return to the previous screen, then deselect Workstation Array Manager and click Next.

#2: If you are attempting to install Global Array Manager Server under Windows 95 (or Windows 98), you will see a message of the following type (Figure 3-7):

Figure 3-7. Error – SERVER Must Be Installed Under Windows NT/2000

Click OK, then do one of the following: a) deselect Global Array Manager Server and install GAM Client, OR, b) click Cancel and then click Exit to quit the installation of GAM Server. You must install GAM Server on Windows NT or 2000.

Manual No. 775078 3-7

Global Array Manager Server Software for Windows NT 4.0

#3: If setup finds a previous installation of GAM Server software and/or the GAM Driver, you will see the following message (Figure 3-8).

Figure 3-8. Previous GAM Server or GAM Driver Found

Click Yes to proceed with replacing the existing GAM Server and GAM Driver with the new installation, OR

Click No to retain your existing GAM Server/GAM Driver installation. Since only one GAM Server/GAM Driver can be present on a server system, setup will exit if you click No.

11. The Installation Summary screen (Figure 3-9) summarizes the components and subcomponents you’ve selected for installation. Click Next to continue, or click Back to change selected components.

Figure 3-9. Installation Summary Screen

3-8 Global Array Manager Server Software Manual

Windows NT

3WINNT

12. Special Condition: Old PCI Controller Drivers

If setup finds that an installed PCI driver for any of your Mylex PCI RAID Controllers is older than version 6.00-00, you will see a message

of the following type1 (Figure 3-10):

Figure 3-10. Error – PCI Driver Must Be Version 6.00-00 or Higher

If you will use GAM Server only with Mylex External RAID Controllers, you should choose to continue installation by clicking OK.

However, if you will use GAM Server with Mylex PCI RAID Controllers, your PCI Controller Drivers must be version 6.00-00 or higher in order to be able to install and run GAM Server. Click Cancel and setup will exit.

After clicking Cancel, follow the instructions in the PCI Disk Array Controller Drivers Installation Guide and User Manual to update your PCI driver(s). Then rerun GAM Server installation as described herein.

If the above Special Condition does not apply, installation will continue. Go on to Step 13.

1. The actual driver identified in the message will depend on which driver is found to be older than version 6.00-00.

Manual No. 775078 3-9

Global Array Manager Server Software for Windows NT 4.0

13. During installation, files are decompressed and copied from the installation CD-ROM to the destination folder (Figure 3-11).

Wait for this process to complete.

Figure 3-11. Installation Progress Display

14. If the Setup function detects an existing Global Array Manager Server configuration file, the following message appears (Figure 3-12).

Figure 3-12. Existing GAM Server Detected. Overwrite?

• Click Yes to overwrite the existing configuration file. Skip ahead to Step 21 on page 3-14, OR

• Click No to retain the existing configuration file and continue with the next step.

15. If you click No from the dialog box in Figure 3-12, (existing server configuration detected) the question box in Figure 3-13 appears.

3-10 Global Array Manager Server Software Manual

Windows NT

3WINNT

Figure 3-13. Existing Configuration to be Used

• Click Yes to proceed. Your existing configuration file will continue to be used. Go on to Step 16 (Figure 3-14), OR

• Click No to return to the screen shown in Figure 3-12, and go back to Step 14.

Figure 3-14. Directory Path for gamscm.ini File

16. The full path for the configuration file is identified for future reference. Click OK to proceed to the View Readme Files (Figure 3-15).

Manual No. 775078 3-11

Global Array Manager Server Software for Windows NT 4.0

Figure 3-15. View Readme File(s)

17. If you also installed Global Array Manager Client, your screen will display the names of both readme files.

To view changes and updates to the program or installation guide, check the box which reads “Read the Global Array Manager Server readme file now,” then click Next.

If you do not check the box, click Next and skip ahead to Step 20.

18. If you chose to view the ReadMe file, the Notepad accessory will open and the file will be presented.

Read the contents of this file for the most up-to-date information about Global Array Manager Server. Much of this information may not appear in this installation guide, as sometimes last-minute modifications to the software are done after completion of the guide. You may also wish to print the contents of this file.

19. Close the Notepad accessory after reading and/or printing.

20. The Setup Complete dialog box displays (Figure 3-16).

3-12 Global Array Manager Server Software Manual

Windows NT

3WINNT

Figure 3-16. Setup Complete

Setup has finished copying files to your computer.

• Select Yes and click Finish if you are ready to reboot your computer. OR

• Select No and click Finish if you want to exit setup and perform other tasks before rebooting.

� NoteYou need not reboot immediately, but you must reboot your system before the Global Array Manager Server software will be available for use.

Create a user account called gamroot. Assign Administrator access privileges to that user account.

� NoteGAM Client only allows account gamroot to have Administration rights on Mylex controllers.

Setup of Global Array Manager Server is complete.

Manual No. 775078 3-13

Global Array Manager Server Software for Windows NT 4.0

21. If you chose Yes at the question shown earlier in Step 14 (Figure 3-12) to replace the existing configuration file, another question screen appears (Figure 3-17).

Figure 3-17. Existing Configuration will be Renamed

This question dialog box asks for confirmation that you want to replace the existing configuration file with a new one, and informs you that your existing file will be renamed.

• Click Yes to accept the new configuration file and have your existing file renamed. Go on to Step 22, OR

• Click No to cancel the request, then return to Step 14 on page 3-10.

3-14 Global Array Manager Server Software Manual

Windows NT

3WINNT

22. The Modify Server Configuration File dialog box appears so that you can add IP addresses or names of client workstations that will receive event notifications from this server, enable External Controller support, and/or enable server event logging (Figure 3-18).

Figure 3-18. Modify Server Configuration File, IP Addresses

� NoteIf your client is running Windows NT or Windows 2000, you can enter a node name for the client instead of an IP address.

Type in the IP addresses (or names) for your client workstations in the fields provided.

� NoteIf entering only one IP address or name, it must be entered in box #1.

Manual No. 775078 3-15

Global Array Manager Server Software for Windows NT 4.0

� NoteIt is not required that you fill in these fields. However, no event notifications can be received by a client unless its IP address or name is identified. You may include additional IP addresses or node names by editing the GAMSCM.INI (configuration file) later. See Appendix E “GAMEVENT”.

23. If you will be using any Mylex External RAID Controllers (such as DAC960SX, DAC960SF, DACFF, etc.), check the box beside “Enable External RAID Controller Support” shown in Figure 3-18. Setup makes some minor modifications to the configuration file to enable support for these controllers.

� NoteIf you have only PCI controllers, you can leave the box unchecked. If you later add External controllers, edit the GAMCONFG line in the GAMSCM.INI configuration file to enable External controller support. See Appendix C “External RAID Support Enabling” for more details.

24. If you would like the server to keep a local log file of all events that are generated by the server (GAMEVLOG.LOG), check the box beside “Enable Server Event Logging” shown in Figure 3-18.

If you do not check the box and wish to enable server event logging later, see Appendix E “GAMEVENT”.

25. Click Next to continue with GAM Server installation.

26. The full path for the configuration file is identified for future reference (Figure 3-19).

3-16 Global Array Manager Server Software Manual

Windows NT

3WINNT

Figure 3-19. Directory Path Information for gamscm.ini File

Click OK to proceed to the View Readme files dialog box (Figure 3-20).

Figure 3-20. View Readme Files

27. If you also installed Global Array Manager Client, your screen will display the names of both readme files.

To view changes and updates to the program or installation guide, check the box which reads “Read the Global Array Manager Server readme file now,” then click Next.

Manual No. 775078 3-17

Global Array Manager Server Software for Windows NT 4.0

If you do not check the box, click Next and skip ahead to Step 30.

28. If you choose to view the ReadMe file, the Notepad accessory will open and the file will be presented.

Read the contents of this file for the most up-to-date information about Global Array Manager Server. Much of this information may not appear in this installation guide, as sometimes last-minute modifications to the software are done after completion of the guide. You may also wish to print the contents of this file.

29. Close the Notepad accessory after reading and/or printing.

30. The Setup Complete dialog box displays (Figure 3-21).

Figure 3-21. Setup Complete.

Setup has finished copying files to your computer.

• Select Yes and click Finish if you are ready to reboot your computer, OR

• Select No and click Finish if you want to exit setup and perform other tasks before rebooting.

3-18 Global Array Manager Server Software Manual

Windows NT

3WINNT

� NoteYou need not reboot immediately, but you must reboot your system before the Global Array Manager Server software will be available for use.

31. Create a user account called gamroot. Assign Administrator access privileges to that user account.

� NoteGAM Client only allows account gamroot to have Administration rights on Mylex controllers.

Setup of Global Array Manager Server is complete.

Manual No. 775078 3-19

Global Array Manager Server Software for Windows NT 4.0

Running Global Array Manager Server

The Global Array Manager Server runs on the server and performs the following functions:

• Monitors the controller(s) and disks in the server.

• Manages the controller(s) and associated disk subsystems in the server.

• Sends information to Global Array Manager Clients (if used).

The automatic installation procedure for Windows NT’s Global Array Manager Server loads the GAM Server component as a “service.” This service will load automatically at system startup. No special procedure is required to run the GAM Windows NT Server.

To verify that this service has started, go to Start->Control Panel->Services. Find the Mylex GAM Server name. The word “Started” should appear beside it.

Setup automatically installs the GAM driver. To verify that it is installed and running, go to Start->Control Panel->Devices. Scroll to ‘gamdrv.’ It should say ‘started’ and ‘Boot.’

Troubleshooting Server Software Installation

Problem: The message “Error in connecting selected server” is displayed or an error is encountered when trying to connect to a server.

Check: Is the IP address of the Server correct?

Check: Is the Ethernet connection good?

Check: Is TCP/IP set up correctly? Try Ping to find the server.

Problem: Global Array Manager Server does not load.

Check: Did all of the server files load to the destination directories? Do you have sufficient disk space for the installation? A list of files needed for operation is given in Chapter 1. If necessary, reinstall the software.

3-20 Global Array Manager Server Software Manual

Windows NT

3WINNT

DMI Manual ConfigurationDMI files are available for the Mylex Disk Array Controller running under Windows NT. The DMI will act as a general monitor to locate events such as, hard disk status, driver identification, etc.

DMI files must be manually configured after they are copied into the server directory by the GAM server installation.

DMI is selected in the sub-component dialog box during the Global Array Manager Server installation. The DMI subcomponent can also be installed by itself via the server installation utility.

Use the SRVCCFG.EXE utility to configure the DMI files.

You will need to run the following command line from the GAMSERV directory to install the mdacci service manually:

srvccfg mdacci “Mylex DMI Service” %SystemRoot%\system32\gamserv\mdacci.exe

DMI FilesThere are three DMI files:

• MDAC.MIF

• MDACCI.EXE

• SRVCCFG.EXE

These files will be copied into the appropriate directory path during the GAM Server installation process:

%SystemRoot%\system32\gamserv\mdac.mif

%SystemRoot%\system32\gamserv\mdacci.exe

%SystemRoot%\system32\gamserv\srvccfg.exe

If the GAM Server installation detects the system environment variable (%win32dmipath%) created by Intel’s LANDesk Server Manager, these files will also be copied into the following locations:

%win32dmipath%\mifs\mdac.mif.

%win32dmipath%\bin\mdacci.exe.

Manual No. 775078 3-21

DMI Manual Configuration

� NoteIf you are using Intel LANDesk Service Manager, you do not need to manually configure mdacci.exe. Intel’s application will take care of this.

3-22 Global Array Manager Server Software Manual

Chapter 4Windows 2000

4WIN2000

OverviewThis chapter describes installation, verification, and startup of the Global Array Manager (GAM) Server software for Microsoft Windows 2000. The software is provided on the Software Kit CD-ROM.

� NoteThis chapter assumes that the network administrator for this site will be performing these installation procedures.

Manual No. 775078 4-1

Global Array Manager Server Software for Windows 2000

Global Array Manager Server Software for Windows 2000

Installation Overview

Installation of the Global Array Manager Server component requires the Windows 2000 operating system. It will not work on a Windows 95 or Windows 98 operating system.

Reminder: This chapter assumes that the network administrator for this site will be performing these installation procedures.

You may also choose to install GAM Client at the same time on the same system. Refer to the appropriate Global Array Manager Client Software Installation Guide and User Manual for GAM Client installation instructions.

File List

Global Array Manager software is shipped on an accompanying distribution CD-ROM. The file list (and path) is as follows (where X: represents the drive letter of your CD-ROM drive):

X:\GAM\WIN2K\

_INST32I.EX_ DATA.TAG SETUP.EXE_ISDEL.EXE DATA1.CAB SETUP.INI_SETUP.DLL DATA1.HDR SETUP.INS_SYS1.CAB LANG.DAT SETUP.LID_SYS1.HDR LAYOUT.BIN_USER1.CAB OS.DAT_USER1.HDR

4-2 Global Array Manager Server Software Manual

Windows 2000

4WIN2000

Installing Global Array Manager Server Software

Follow the steps below to install GAM Server software for Windows 2000.

1. Make sure TCP/IP is installed and functioning properly.

2. Insert the Software Kit CD-ROM into your CD-ROM drive.

AutoRun will cause the CD-ROM to display the Mylex RAID Management Software Installation menu (Figure 4-1).

Figure 4-1. Mylex RAID Management Software Installation Menu

3. Click on the option called “Install Global Array Manager.” This option is used to install GAM Server.

Global Array Manager Setup loads the installation wizard (Figure 4-2).

Figure 4-2. Loading the Installation Wizard

Manual No. 775078 4-3

Global Array Manager Server Software for Windows 2000

4. After a few moments, the Welcome dialog box appears (Figure 4-3). Click Next to proceed with the installation, or click Cancel to end the installation procedure and return to the menu.

Figure 4-3. Welcome Dialog Box

5. When the Mylex Software License Agreement screen appears, click Yes to accept the terms of the agreement and continue.

If you click No, you will not be allowed to continue GAM Server installation.

4-4 Global Array Manager Server Software Manual

Windows 2000

4WIN2000

The Select Components dialog box is displayed as shown in Figure 4-4. At this point you will select the component(s) you wish to install.

Figure 4-4. Select Components to Install

6. To select Global Array Manager Server for installation, click the box to check the Global Array Manager Server option.

� NoteYou may also choose to install Global Array Manager Client at this time. If you wish to install both GAM Server and GAM Client, please refer to the appropriate Global Array Manager Client Installation Guide and User Manual to install the Global Array Manager Client.

Manual No. 775078 4-5

Global Array Manager Server Software for Windows 2000

7. When you select and highlight the Global Array Manager Server option, the Change button becomes active so that you can access the Select Sub-components screen.

If you do not wish to change the subcomponents, click Next and proceed to Step 10 on page 4-7, OR

Click Change to see the Select Sub-components screen (Figure 4-5). Driver and Program Files should remain selected. DMI and SNMP may be selected or deselected as needed:

• If you select DMI, Setup copies the DMI files to the server directory, but it does not configure the DMI files. Please refer to “DMI Manual Configuration” on page 4-21.

• If you select SNMP, the SNMP files are copied to the server directory and configured automatically. For more information about SNMP support in Mylex products, please refer to Appendix A.

Figure 4-5. Sub-Components List

4-6 Global Array Manager Server Software Manual

Windows 2000

4WIN2000

8. Make your subcomponent selections, then click Continue to return to the “Select Components” dialog box, Figure 4-4.

9. Click Next from the “Select Components” dialog box to continue with the installation.

10. Special Conditions: GAM Server Installation

#1: If you have attempted to install Workstation Array Manager, you will see the following message (Figure 4-6).

Figure 4-6. Error – Must Choose GAM Server OR WSAM

Click OK to return to the previous screen, then deselect Workstation Array Manager and click Next.

#2: If you are attempting to install Global Array Manager Server under Windows 95 (or Windows 98), you will see a message of the following type (Figure 4-7):

Figure 4-7. Error – SERVER Must Be Installed Under Windows NT/2000

Click OK, then do one of the following: a) deselect Global Array Manager Server and install GAM Client, OR, b) click Cancel and then click Exit to quit the installation of GAM Server. You must install GAM Server on Windows NT or 2000.

Manual No. 775078 4-7

Global Array Manager Server Software for Windows 2000

#3: If setup finds a previous installation of GAM Server software and/or the GAM Driver, you will see the following message (Figure 4-8).

Figure 4-8. Previous GAM Server or GAM Driver Found

Click Yes to proceed with replacing the existing GAM Server and GAM Driver with the new installation, OR

Click No to retain your existing GAM Server/GAM Driver installation. Since only one GAM Server/GAM Driver can be present on a server system, setup will exit if you click No.

11. The Installation Summary screen (Figure 4-9) summarizes the components and subcomponents you’ve selected for installation. Click Next to continue, or click Back to change selected components.

Figure 4-9. Installation Summary Screen

4-8 Global Array Manager Server Software Manual

Windows 2000

4WIN2000

12. Special Condition: Old PCI Controller Drivers

If setup finds that an installed PCI driver for any of your Mylex PCI RAID Controllers is older than version 6.00-00, you will see a message

of the following type1 (Figure 4-10):

Figure 4-10. Error – PCI Driver Must Be Version 6.00-00 or Higher

If you will use GAM Server only with Mylex External RAID Controllers, you should choose to continue installation by clicking OK.

However, if you will use GAM Server with Mylex PCI RAID Controllers, your PCI Controller Drivers must be version 6.00-00 or higher in order to be able to install and run GAM Server. Click Cancel and setup will exit.

After clicking Cancel, follow the instructions in the PCI Disk Array Controller Drivers Installation Guide and User Manual to update your PCI driver(s). Then rerun GAM Server installation as described herein.

If the above Special Condition does not apply, installation will continue. Go on to Step 13.

1. The actual driver identified in the message will depend on which driver is found to be older than version 6.00-00.

Manual No. 775078 4-9

Global Array Manager Server Software for Windows 2000

13. During installation, files are decompressed and copied from the installation CD-ROM to the destination folder (Figure 4-11).

Wait for this process to complete.

Figure 4-11. Installation Progress Display

14. If the Setup function detects an existing Global Array Manager Server configuration file, the following message appears (Figure 4-12).

Figure 4-12. Existing GAM Server Detected. Overwrite?

• Click Yes to overwrite the existing configuration file. Skip ahead to Step 21 on page 4-14, OR

• Click No to retain the existing configuration file and continue with the next step.

15. If you click No from the dialog box in Figure 4-12, (existing server configuration detected) the question box in Figure 4-13 appears.

4-10 Global Array Manager Server Software Manual

Windows 2000

4WIN2000

Figure 4-13. Existing Configuration to be Used

• Click Yes to proceed. Your existing configuration file will continue to be used. Go on to Step 16 (Figure 4-14), OR

• Click No to return to the screen shown in Figure 4-12, and go back to Step 14.

Figure 4-14. Directory Path for gamscm.ini File

16. The full path for the configuration file is identified for future reference. Click OK to proceed to the View Readme Files (Figure 4-15).

Manual No. 775078 4-11

Global Array Manager Server Software for Windows 2000

Figure 4-15. View Readme File(s)

17. If you also installed Global Array Manager Client, your screen will display the names of both readme files.

To view changes and updates to the program or installation guide, check the box which reads “Read the Global Array Manager Server readme file now,” then click Next.

If you do not check the box, click Next and skip ahead to Step 20.

18. If you chose to view the ReadMe file, the Notepad accessory will open and the file will be presented.

Read the contents of this file for the most up-to-date information about Global Array Manager Server. Much of this information may not appear in this installation guide, as sometimes last-minute modifications to the software are done after completion of the guide. You may also wish to print the contents of this file.

19. Close the Notepad accessory after reading and/or printing.

20. The Setup Complete dialog box displays (Figure 4-16).

4-12 Global Array Manager Server Software Manual

Windows 2000

4WIN2000

Figure 4-16. Setup Complete

Setup has finished copying files to your computer.

• Select Yes and click Finish if you are ready to reboot your computer, OR

• Select No and click Finish if you want to exit setup and perform other tasks before rebooting.

� NoteYou need not reboot immediately, but you must reboot your system before the Global Array Manager Server software will be available for use.

Create a user account called gamroot. Assign Administrator access privileges to that user account.

� NoteGAM Client only allows account gamroot to have Administration rights on Mylex controllers.

Setup of Global Array Manager Server is complete.

Manual No. 775078 4-13

Global Array Manager Server Software for Windows 2000

21. If you chose Yes at the question shown earlier in Step 14 (Figure 4-12) to replace the existing configuration file, another question screen appears (Figure 4-17).

Figure 4-17. Existing Configuration will be Renamed

This question dialog box asks for confirmation that you want to replace the existing configuration file with a new one, and informs you that your existing file will be renamed.

• Click Yes to accept the new configuration file and have your existing file renamed. Go on to Step 22, OR

• Click No to cancel the request, then return to Step 14 on page 4-10.

4-14 Global Array Manager Server Software Manual

Windows 2000

4WIN2000

22. The Modify Server Configuration File dialog box appears so that you can add IP addresses or names of client workstations that will receive event notifications from this server, enable External Controller support, and/or enable server event logging (Figure 4-18).

Figure 4-18. Modify Server Configuration File, IP Addresses

� NoteIf your client is running Windows NT or Windows 2000, you can enter a node name for the client instead of an IP address.

Type in the IP addresses (or names) for your client workstations in the fields provided.

� NoteIf entering only one IP address or name, it must be entered in box #1.

Manual No. 775078 4-15

Global Array Manager Server Software for Windows 2000

� NoteIt is not required that you fill in these fields. However, no event notifications can be received by a client unless its IP address or name is identified. You may include additional IP addresses or node names by editing the GAMSCM.INI (configuration file) later. See Appendix E “GAMEVENT”.

23. If you will be using any Mylex External RAID Controllers (such as DAC960SX, DAC960SF, DACFF, etc.), check the box beside “Enable External RAID Controller Support” shown in Figure 4-18. Setup makes some minor modifications to the configuration file to enable support for these controllers.

� NoteIf you have only PCI controllers, you can leave the box unchecked. If you later add External controllers, edit the GAMCONFG line in the GAMSCM.INI configuration file to enable External controller support. See Appendix C “External RAID Support Enabling” for more details.

24. If you would like the server to keep a local log file of all events that are generated by the server (GAMEVLOG.LOG), check the box beside “Enable Server Event Logging” shown in Figure 4-18.

If you do not check the box and wish to enable server event logging later, see Appendix E “GAMEVENT”.

25. Click Next to continue with GAM Server installation.

26. The full path for the configuration file is identified for future reference (Figure 4-19).

4-16 Global Array Manager Server Software Manual

Windows 2000

4WIN2000

Figure 4-19. Directory Path Information for gamscm.ini File

Click OK to proceed to the View Readme files dialog box (Figure 4-20).

Figure 4-20. View Readme Files

27. If you also installed Global Array Manager Client, your screen will display the names of both readme files.

To view changes and updates to the program or installation guide, check the box which reads “Read the Global Array Manager Server readme file now,” then click Next.

If you do not check the box, click Next and skip ahead to Step 30.

Manual No. 775078 4-17

Global Array Manager Server Software for Windows 2000

28. If you choose to view the ReadMe file, the Notepad accessory will open and the file will be presented.

Read the contents of this file for the most up-to-date information about Global Array Manager Server. Much of this information may not appear in this installation guide, as sometimes last-minute modifications to the software are done after completion of the guide. You may also wish to print the contents of this file.

29. Close the Notepad accessory after reading and/or printing.

30. The Setup Complete dialog box displays (Figure 4-21).

Figure 4-21. Setup Complete.

Setup has finished copying files to your computer.

• Select Yes and click Finish if you are ready to reboot your computer, OR

• Select No and click Finish if you want to exit setup and perform other tasks before rebooting.

4-18 Global Array Manager Server Software Manual

Windows 2000

4WIN2000

� NoteYou need not reboot immediately, but you must reboot your system before the Global Array Manager Server software will be available for use.

31. Create a user account called gamroot. Assign Administrator access privileges to that user account.

� NoteGAM Client only allows account gamroot to have Administration rights on Mylex controllers.

Setup of Global Array Manager Server is complete.

Manual No. 775078 4-19

Global Array Manager Server Software for Windows 2000

Running Global Array Manager Server

The Global Array Manager Server runs on the server and performs the following functions:

• Monitors the controller(s) and disks in the server.

• Manages the controller(s) and associated disk subsystems in the server.

• Sends information to Global Array Manager Clients (if used).

The automatic installation procedure for Windows 2000’s Global Array Manager Server loads the GAM Server component as a “service.” This service will load automatically at system startup. No special procedure is required to run the GAM for Windows 2000 on the Server.

Troubleshooting Server Software Installation

Problem: The message “Error in connecting selected server” is displayed or an error is encountered when trying to connect to a server.

Check: Is the IP address of the Server correct?

Check: Is the Ethernet connection good?

Check: Is TCP/IP set up correctly? Try Ping to find the server.

Problem: Global Array Manager Server does not load.

Check: Did all of the server files load to the destination directories? Do you have sufficient disk space for the installation? A list of files needed for operation is given in Chapter 1. If necessary, reinstall the software.

4-20 Global Array Manager Server Software Manual

Windows 2000

4WIN2000

DMI Manual ConfigurationDMI files are available for the Mylex Disk Array Controller running under Windows 2000. The DMI will act as a general monitor to locate events such as hard disk status, driver identification, etc.

DMI files must be manually configured after they are copied into the server directory by the GAM server installation.

DMI is selected in the sub-component dialog box during the Global Array Manager Server installation. The DMI subcomponent can also be installed by itself via the server installation utility.

Use the SRVCCFG.EXE utility to configure the DMI files.

You will need to run the following command line from the GAMSERV directory to install the mdacci service manually:

srvccfg mdacci “Mylex DMI Service” %SystemRoot%\system32\gamserv\mdacci.exe

DMI Files

There are three DMI files:

• MDAC.MIF

• MDACCI.EXE

• SRVCCFG.EXE

These files will be copied into the appropriate directory path during the GAM Server installation process:

%SystemRoot%\system32\gamserv\mdac.mif

%SystemRoot%\system32\gamserv\mdacci.exe

%SystemRoot%\system32\gamserv\srvccfg.exe

If the GAM Server installation detects the system environment variable (%win32dmipath%) created by Intel’s LANDesk Server Manager, these files will also be copied into the following locations:

%win32dmipath%\mifs\mdac.mif.

%win32dmipath%\bin\mdacci.exe.

Manual No. 775078 4-21

DMI Manual Configuration

� NoteIf you are using Intel LANDesk Service Manager, you do not need to manually configure mdacci.exe. Intel’s application will take care of this.

4-22 Global Array Manager Server Software Manual

Chapter 5SCO OpenServer

5 SCO

OverviewThis chapter describes information about the following installation, verification, and startup of the Global Array Manager Server software for SCO OpenServer Release 5.0.5. The software is provided on the appropriate Software Kit CD-ROM with a file to create a diskette.

� NoteThis chapter assumes that the network administrator for this site will be performing these installation procedures.

Manual No. 775078 5-1

Global Array Manager Server Software for SCO OpenServer 5.0.5

Global Array Manager Server Software for SCO OpenServer 5.0.5

Creating the Global Array Manager Server Diskette

Before installing the GAM Server for SCO UNIX, a diskette must be created according to the instructions below.

This diskette will be used wherever instructed to insert the “GAM Server diskette for SCO UNIX.”

1. Insert a DOS formatted diskette into drive A.

2. Insert the Software Kit CD-ROM into the CD-ROM drive.

3. From the DOS prompt type F:\gam\sco\diskimg\gamssco5 a: <Enter>

where F: identifies the CD-ROM drive.

4. You will get a message asking if you want the disk to be overwritten to continue. Type Y for Yes and press <Enter>.

5. Label this disk as “GAM Server diskette for SCO UNIX” and save until needed.

� NoteAfter creating this diskette, DOS is not able to read it.

Installing Global Array Manager Server Software

Use pkgadd to install the Global Array Manager Server software for SCO UNIX. Complete the following procedure.

� NoteThese instructions assume the installation diskette is in the first diskette drive. If a different source is used, substitute the location for “/dev/rfd0” below.

1. Log in as root.

2. Insert the GAM Server diskette for SCO UNIX in the file server’s diskette drive.

5-2 Global Array Manager Server Software Manual

SCO OpenServer

5 SCO

3. Type the following (match case exactly as shown):

pkgadd -d /dev/rfd0 GAM ↵

The files are copied. The Kernel is rebuilt.

4. A prompt to boot this Kernel by default is shown:

Do you want this kernel to boot by default? (y/n)

Select “y” to boot from this Kernel.

5. You are prompted to rebuild the Kernel environment as shown:

Do you want the kernel environment rebuilt? (y/n)

Select “y”.

6. Installation is complete.

• Modify the GAMEVENT and GAMEVLOG lines manually. Do this by editing the S99GAM file found in the directory /etc/rc2.d, changing the GAMEVENT line to include (after each -h parameter) the IP addresses of the client systems you will use with this server. Modify the pathname and filename in the GAMEVLOG command line if you wish to. Refer to Appendix E, GAMEVENT, for more information.

• If you wish to enable RAID Fault Management (RAIDBUILD) and optionally change its default parameters, you need to modify the RAIDBLD command line installed in S99GAM. Refer to Appendix B, RAID Fault Management, for information.

• If you will be using drives from more than one vendor in the same RAID Group, refer to Appendix D, The MYLEXDRV.SIZ File, for information on setting drive size limits for consistency across multiple vendors’ drives.

7. Be sure to remove comment markers (such as the character #) from any command line which you intend to enable.

8. Save the modified S99GAM and exit.

9. Create a user account called gamroot. Assign Root access privileges to that user account.

10. Reboot the system using the following command from the root directory (match case exactly as shown):

Manual No. 775078 5-3

Global Array Manager Server Software for SCO OpenServer 5.0.5

shutdown -y -i6 -g0 ↵

Running Global Array Manager Server

The Global Array Manager Server runs on the server and performs the following functions:

• Monitors the controller(s) and disks in the server.

• Manages the controller(s) and associated disk subsystems in the server.

• Sends information to Global Array Manager Clients (if used).

The installation of Global Array Manager Server for SCO UNIX causes the appropriate drivers to load automatically at system startup. No additional actions are required to start GAM Server beyond a system boot.

Troubleshooting Server Software Installation

Problem: An error is encountered when trying to connect to a server.

Check: Is the IP address of the Server correct?

Check: Is the installation complete? Was the software successfully loaded on the server?

Check: Is the Ethernet connection good?

Check: Is TCP/IP set up correctly? Try Ping to find the server.

Problem: Global Array Manager Server does not load.

Check: Do you have login rights to the root?

Check: Did all of the server files load to the destination directory? Do you have sufficient disk space for the installation? If necessary, reinstall the software.

Uninstalling the Server Software

To remove the Global Array Manager Server software, complete the following procedure.

1. Type the following command (match case exactly as shown):

pkgrm GAM ↵

5-4 Global Array Manager Server Software Manual

SCO OpenServer

5 SCO

2. You are prompted for confirmation as shown:

Do you want to remove this package? [y,n,?,q]

Select “y”. The files are removed. The Kernel is rebuilt.

3. You are prompted to boot this Kernel by default:

Do you want this kernel to boot by default? (y/n)

To boot this kernel by default, select “y”.

4. You are prompted to rebuild the Kernel environment:

Do you want the kernel environment rebuilt? (y/n)

Select “y” to rebuild the Kernel environment.

5. Removal is complete. Reboot the system, using the following command from the root directory (match case exactly as shown):

shutdown -y -i6 -g0 ↵

Manual No. 775078 5-5

Global Array Manager Server Software for SCO OpenServer 5.0.5

5-6 Global Array Manager Server Software Manual

Chapter 6UnixWare

6UNIXWARE

OverviewThis chapter describes information about the following installation, verification, and startup of the Global Array Manager Server software for UnixWare 7.x and UnixWare 2.1.2 and 2.1.3. The software is provided on the appropriate Software Kit distribution CD-ROM with a file to create a diskette.

� NoteThis chapter assumes that the network administrator for this site will be performing these installation procedures.

Manual No. 775078 6-1

Global Array Manager Server Software for UnixWare 7.x, 2.1.2, and 2.1.3

Global Array Manager Server Software for UnixWare 7.x, 2.1.2, and 2.1.3

Creating the Global Array Manager Server Diskette

Before installing the GAM Server for UnixWare, a diskette must be created according to the instructions below.

This diskette will be used in the next section wherever instructed to insert the “GAM Server diskette for UnixWare.”

1. Insert a DOS formatted diskette into drive A.

2. Insert the CD-ROM into the CD-ROM drive.

3. From the DOS prompt type F:\gam\unixware\diskimg\gamsuw a: <Enter>

where F: identifies the CD-ROM drive.

4. You will get a message asking if you want the disk to be overwritten to continue. Type Y for Yes and press <Enter>.

5. Label this disk as “GAM Server diskette for UnixWare” and save until needed.

� NoteAfter creating this diskette, DOS is not able to read it.

Installing Global Array Manager Server Software

Use pkgadd to install the Global Array Manager Server software for UnixWare. Complete the following procedure.

� NoteThese instructions assume the installation diskette is in disk drive 1. If a different source is used, substitute the location for “diskette1” below.

1. Log in as root.

2. Insert the GAM Server diskette for UnixWare in the file server’s diskette drive.

6-2 Global Array Manager Server Software Manual

UnixWare

6UNIXWARE

3. Type the following (match case exactly as shown):

pkgadd -d diskette1 GAM ↵

4. You are prompted to insert the diskette and confirm installation as shown:

Insert diskette into Floppy Drive 1.Type [go] when ready.or [q] to quit: (default: go)

To begin installation, type:

go ↵

The files are copied and the Kernel is rebuilt.

5. Installation is complete.

• Modify the GAMEVENT and GAMEVLOG lines manually. Do this by editing the S99GAM file found in the directory /etc/rc2.d, changing the GAMEVENT line to include (after each -h parameter) the IP addresses of the client systems you will use with this server. Modify the pathname and filename in the GAMEVLOG command line if you wish to. Refer to Appendix E, GAMEVENT, for information.

• If you wish to enable RAID Fault Management (RAIDBUILD) and optionally change its default parameters, you need to modify the RAIDBLD command line installed in S99GAM. Refer to Appendix B, RAID Fault Management, for information.

• If you will be using drives from more than one vendor in the same RAID Group, refer to Appendix D, The MYLEXDRV.SIZ File, for information on setting drive size limits for consistency across multiple vendors’ drives.

6. Be sure to remove comment markers (such as the character #) from any command line which you intend to enable.

7. Save the modified S99GAM and exit.

8. Create a user account called gamroot. Assign Root access privileges to that user account.

9. Reboot the system using the following command from the root directory (match case exactly as shown):

Manual No. 775078 6-3

Global Array Manager Server Software for UnixWare 7.x, 2.1.2, and 2.1.3

shutdown -y -i6 -g0 ↵

Running Global Array Manager Server

The Global Array Manager Server runs on the server and performs the following functions:

• Monitors the controller(s) and disks in the server.

• Manages the controller(s) and associated disk subsystems in the server.

• Sends information to Global Array Manager Clients (if used).

The installation of Global Array Manager Server for UnixWare causes the appropriate drivers to load automatically at system startup. No additional actions are required to start GAM Server beyond a system boot.

Troubleshooting Server Software Installation

Problem: An error is encountered when trying to connect to a server.

Check: Is the IP address of the Server correct?

Check: Is the installation complete? Was the software successfully loaded on the server?

Check: Is the Ethernet connection good?

Check: Is TCP/IP installed?

Check: Is TCP/IP set up correctly? Try Ping to find the server.

Problem: Global Array Manager Server does not load.

Check: Do you have login rights to the root?

Check: Did all of the server files load to the destination directory? Do you have sufficient disk space for the installation? If necessary, reinstall the software.

6-4 Global Array Manager Server Software Manual

UnixWare

6UNIXWARE

Uninstalling the Server Software

To remove the Global Array Manager Server software, complete the following procedure.

1. Type the following command (match case exactly as shown):

pkgrm GAM ↵

2. You are prompted for confirmation as shown:

Do you want to remove this package [yes,no,?,quit]

At the prompt, type:

y ↵

The files are removed. The Kernel is rebuilt.

3. When you see the following message, removal is complete.

Removal of <GAM> was successful.

4. Reboot the system using the following command from the root directory (match case exactly as shown):

shutdown -y -i6 -g0 ↵

Manual No. 775078 6-5

Global Array Manager Server Software for UnixWare 7.x, 2.1.2, and 2.1.3

6-6 Global Array Manager Server Software Manual

Chapter 7Solaris

7SOLARIS

OverviewThis chapter describes information about the following installation, verification, and startup of the Global Array Manager Server software for Solaris 7.0. The software is provided on the appropriate Software Kit distribution CD-ROM with a file to create a diskette.

The Solaris driver for the Mylex Disk Array Controller supports disk drives, tape drives and CD-ROM drives under Solaris 7.0. The driver supports up to 16 controllers. Also, the driver supports secondary system drives larger than 8GB.

� NoteThis chapter assumes that the network administrator for this site will be performing these installation procedures.

Manual No. 775078 7-1

Global Array Manager Server Software for Solaris 7.0

Global Array Manager Server Software for Solaris 7.0

Creating the Global Array Manager Server Diskette

Before installing the GAM Server for Solaris, a diskette must be created according to the instructions below.

This diskette will be used in the next section wherever instructed to insert the “GAM Server diskette for Solaris.”

1. Insert a DOS formatted diskette into drive A.

2. Insert the Software Kit CD-ROM into the CD-ROM drive.

3. From the DOS prompt type F:\gam\solaris\x86\diskimg\gamssolx a: <Enter>

where F: identifies the CD-ROM drive.

4. You will get a message asking if you want the disk to be overwritten to continue. Type Y for Yes and press <Enter>.

5. Label this disk as “GAM Server diskette for Solaris” and save until needed.

� NoteAfter creating this diskette, DOS is not able to read it.

Installing Global Array Manager Server Software

1. Access the root directory.

2. Insert the GAM Server diskette for Solaris in the file server’s disk drive.

3. Type the following command to see if the Volume Management software is running on the computer you are updating:

ps -ef | grep vold

7-2 Global Array Manager Server Software Manual

Solaris

7SOLARIS

� NoteFor more information about managing diskettes and drives, see the System Administration Guide for Solaris.

4. If Volume Management is running, temporarily stop it by typing the following command line at the system prompt.

# /etc/init.d/volmgt stop

5. Insert the GAM Server diskette into the disk drive.

6. Mount the GAM Server diskette at the /mnt mount point by typing the following command:

# mount -F pcfs /dev/diskette /mnt

� NoteYou must mount the GAM Server diskette at this point in the file structure to update your computer successfully.

7. Execute the install script on the diskette, using the appropriate Solaris release directory (sol_27 for Solaris 7). For example:

# /mnt/DU/sol_27/i86pc/Tools/install.sh -i

The install.sh script searches for all new or updated drivers on the diskette. When a new or updated driver is found, the following messages and prompt are displayed:

Unconditionally installing ITUs <gamdrv>Installing package <MYLXgam>

Do you want to continue with the installation of<MYLXgam>?

If the driver is the one you want to install, at the prompt, type Y for Yes or press <Enter>. If the driver is not the one you want, type N for No.

If you select Y for Yes, the install.sh script installs the driver. You will see the following message:

Installation of <MYLXgam> was successful.

Manual No. 775078 7-3

Installing Solaris Using the Solaris Device Configuration Assistant Diskette

8. When you’re done and the install.sh script exits, unmount the diskette by typing the following command lines:

# cd /

# umount /mnt

9. Remove the GAM Server diskette from the disk drive.

10. Reboot your computer, type in the following command lines.

# touch /reconfigure

# reboot

11. Turn off your computer, add the new hardware, and turn on your computer again.

12. When the autoboot sequence prompt is displayed, quickly press <Escape>.

The autoboot sequence is interrupted. The Solaris Device Configuration Assistant screen is displayed.

13. Press <F2> to continue.

Message: “Determining buses...” is displayed.

The Scanning Devices screen is then displayed. System devices are scanned. When scanning is complete, the Identified Devices screen is displayed.

14. Press <F2> to continue.

Message: “Loading driver com.bef...” is displayed.

The boot Solaris screen is then displayed.

15. On the boot Solaris screen, select the device controller attached to the device that contains your install medium, in this case the main system disk.

The following script is displayed.

/etc/bootrc

16. At the prompt, type: (reboot)

b -r

7-4 Global Array Manager Server Software Manual

Solaris

7SOLARIS

17. Installation of GAM Server is complete.

• Modify the GAMEVENT and GAMEVLOG lines manually. Do this by editing the S99GAM file found in the directory /etc/rc2.d, changing the GAMEVENT line to include (after each -h parameter) the IP addresses of the client systems you will use with this server. Modify the pathname and filename in the GAMEVLOG command line if you wish to. Refer to Appendix E, GAMEVENT, for information.

• If you wish to enable RAID Fault Management (RAIDBUILD) and optionally change its default parameters, you need to modify the RAIDBLD command line installed in S99GAM. Refer to Appendix B, RAID Fault Management, for information.

• If you will be using drives from more than one vendor in the same RAID Group, refer to Appendix D, The MYLEXDRV.SIZ File, for information on setting drive size limits for consistency across multiple vendors’ drives.

18. Be sure to remove comment markers (such as the character #) from any command line which you intend to enable.

19. Save the modified S99GAM and exit.

20. Create a user account called gamroot. Assign Root access privileges to that user account.

21. Reboot the system and at the prompt type in the following command from the root directory (match case exactly as shown):

# init 6 ↵

Running Global Array Manager Server

The Global Array Manager Server runs on the server and performs the following functions:

• Monitors the controller(s) and disks in the server.

• Manages the controller(s) and associated disk subsystems in the server.

• Sends information to Global Array Manager Clients (if used).

The installation of Global Array Manager Server for Solaris causes the appropriate drivers to load automatically at system startup. No additional actions are required to start GAM Server beyond a system boot.

Manual No. 775078 7-5

Installing Solaris Using the Mylex MDAC Supplemental Driver Diskette

Troubleshooting Server Software Installation

Problem: An error is encountered when trying to connect to a server.

Check: Is the IP address of the Server correct?

Check: Is the installation complete? Was the software successfully loaded on the server?

Check: Is the Ethernet connection good?

Check: Is TCP/IP installed?

Check: Is TCP/IP set up correctly? Try Ping to find the server.

Problem: Global Array Manager Server does not load.

Check: Do you have login rights to the root?

Check: Did all of the server files load to the destination directory? Do you have sufficient disk space for the installation? If necessary, reinstall the software.

Uninstalling the Server Software

To remove the Global Array Manager Server software, complete the following procedure.

1. Type the following command (match case exactly as shown):

pkgrm GAM ↵

2. You are prompted for confirmation as shown:

Do you want to remove this package [yes,no,?,quit]

At the prompt, type:

y ↵

The files are removed. The Kernel is rebuilt.

3. When you see the following message, removal is complete.

Removal of <GAM> was successful.

4. Reboot the system using the following command from the root directory (match case exactly as shown):

shutdown -y -i6 -g0 ↵

7-6 Global Array Manager Server Software Manual

Chapter 8Linux

8LINUX

OverviewThis chapter describes installation, startup, and troubleshooting of the Global Array Manager Server software for the Linux operating system with the following distributions:

• Red Hat 6.2

• SuSe 6.4

• Caldera 2.4

• Turbo Linux 6.0

The software is provided on the appropriate Software Kit distribution CD-ROM.

� NoteThis chapter assumes that the network administrator for this site will be performing these installation procedures.

Go to the following web sites to download the appropriate Disk Array Controller Drivers:

• For PCI Controllers:

http://www.dandelion.com/Linux/DAC960.html

• For External Controllers:

http://www.qlc.com/bbs-html/csg_web/adapter_pages/driver_pages/21xx/21linux.html

For instructions on how to install the disk array controller drivers, see the appropriate instructions on each web site and refer to the appropriate Linux OS distribution reference manual.

Manual No. 775078 8-1

Global Array Manager Server Software for Linux

Global Array Manager Server Software for Linux

Installation Overview

This section covers the following for the Global Array Manager (GAM) Server software:

• “Installing Global Array Manager Server Software”

• “Running Global Array Manager Server”

• “Troubleshooting Server Software Installation”

• “Uninstalling the Server Software”

This process assumes that the network administrator for this site will be performing this installation procedure.

Installing Global Array Manager Server Software

1. Log in as root.

2. Mount the CD:

mount /dev/cdrom /mnt/cdrom

Before Installing the GAM Server Software, you need to determine if there is already a version installed (Step 3) and then remove it (Step 4). If you are certain that no other version is installed, skip to Step 5.

3. To query the rpm database for GAM:

rpm -qa | grep gam

4. If gam is listed, remove it:

rpm -ev <gam file name>

5. To install the GAM Server Software:

rpm -iv /mnt/cdrom/gam/linux/gamdrv3i.rpm

� NoteThe rpm -iv will make a backup of any previous /etc/mylexdrv.siz or /etc/rc.d/init.d/Gam files before installing new files. Check that the new files contain correct information if the saved version was modified.

8-2 Global Array Manager Server Software Manual

Linux

8LINUX

To query rpm about the contents of the gam file, type:

rpm -qpi <gam file name>

6. Remove the CD from the CD-ROM drive and reboot the system:

shutdown -r now

7. Log in as root.

The installation of Global Array Manager Server for Linux causes the appropriate drivers to load automatically at system startup. No additional actions are required to start GAM Server beyond a system boot.

Running Global Array Manager Server

The Global Array Manager Server runs on the server and performs the following functions:

• Monitors the controller(s) and disks in the server.

• Manages the controller(s) and associated disk subsystems in the server.

• Sends information to Web Array Manager Clients (if used).

� NoteThe device driver (e.g., DAC960 or qla2x00) must be loaded prior to starting Global Array Manager Server software.

To run the GAM Server software, follow these steps:

1. Log in as root.

2. Stop the GAM Server:

/etc/rc.d/init.d/Gam stop

3. Verify that all GAM Server components are gone:

ps -A | grep gamserv

Manual No. 775078 8-3

Global Array Manager Server Software for Linux

4. If you see several process IDs left behind, you will need to remove them by typing:

kill -g gamserv

If necessary, you can also remove process IDs individually by typing:

kill -9 <process ID #>

5. To restart the GAM Server type:

/etc/rc.d/init.d/Gam start

Troubleshooting Server Software Installation

Problem: An error is encountered when trying to connect to a server.

Check: Is the HBA device driver loaded?

If the device driver is not loaded manually (via insmod qla2100) or at boot time, the server connection will not be established since “gamdrvd” was started before the HBA device driver was loaded.

Check: Is the IP address of the Server correct?

Check: Is the installation complete? Was the software successfully loaded on the server?

Check: Is the Ethernet connection good?

Check: Is TCP/IP installed?

Check: Is TCP/IP set up correctly? Try Ping to find the server.

Problem: Global Array Manager Server does not load.

Check: Do you have login rights to the root?

Check: Did all of the server files load to the destination directory? Do you have sufficient disk space for the installation? If necessary, reinstall the software.

8-4 Global Array Manager Server Software Manual

Linux

8LINUX

Uninstalling the Server Software

1. To query the rpm database for GAM:

rpm -qa | grep gam

2. Locate the GAM file name within the list. Type the following to remove GAM:

rpm -ev <gam file name>

Manual No. 775078 8-5

Global Array Manager Server Software for Linux

8-6 Global Array Manager Server Software Manual

Appendix ASNMP Installation,

Operation, and Definition

ASNMP

IntroductionThe Global Array Manager includes a Simple Network Management Protocol (SNMP) agent for the RAID controller and connected arrays. An SNMP - based management application (also known as an SNMP manager) can monitor and manage the disk arrays. An example of an SNMP management application is Hewlett-Packard’s Open View. The SNMP agent can be used to augment the Global Array Manager Client if you are already running an SNMP management application at your site.

SNMP Installation OverviewThe installation of the SNMP agent is accomplished in several phases:

• Installing the agent software on the server

• Placing a copy of the management information base (MIB) in a directory which is accessible to the management application

• Compiling the MIB description file with the management application

SNMP Installation for NetWareDuring installation of the Global Array Manager Server, the SNMP file was copied to its appropriate directory as shown in the table below. The file can also be copied to the server directory from a workstation’s floppy disk drive (with the appropriate NetWare access rights to the server directory).

Table A-1. NetWare SNMP File

Operating system Agent filename Server directory

NetWare GAMAGENT.NLM SYS:SYSTEM

Manual No. 775078 A-1

SNMP Installation for NetWare

Depending upon the SNMP management application used, the MIB (an ASCII text file named MLXRAID.MIB) must be placed in a specific directory on the network management station running the management application. The MLXRAID.MIB file must be manually copied to this directory. For example:

Table A-2. Location for MIB

� NoteYour management application may have a different target directory. Consult the management application’s user guide for the correct location.

Starting the NetWare Agent

To start the agent, enter the appropriate command from the system console:

LOAD GAMAGENT ↵

About the NetWare Agent

The GAMAGENT NLM assumes that SNMP support for NetWare servers (SNMP.NLM) is already installed on the server.

The GAMAGENT NLM will attempt to autoload the SNMP.NLM. If the SNMP.NLM file is not present, the agent will not load.

The command to load the agent can be incorporated into the AUTOEXEC.NCF or other operating system startup files as well.

SNMP Application MIB location

OpenView \OV\MIBS

NetWare NMS \NMS\SNMPMIBS\CURRENT

A-2 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

SNMP Installation for Windows NT or Windows 2000To enable the SNMP agent for Windows NT or Windows 2000, configure Windows NT or Windows 2000 for TCP/IP and SNMP services. The Mylex SNMP Extension Agent file is GAMAGENT.DLL.

Install the SNMP Agent

The Global Array Manager Server installation will copy the necessary files for the Mylex SNMP Extension Agent DLL to be added to the Windows NT registry. If the SNMP agent is required, you should make sure that TCP/IP and Windows NT SNMP services are configured correctly.

� NoteIf SNMP was NOT checked during the original installation, you should re-run the GAM Server installation with SNMP checked before SNMP will be usable. The SNMP option can be selected without the other three components (Driver, Program Files, DMI).

MIB Compilation and Definition File CreationThe next step in the installation involves the integration of the MIB into the management application’s database of events and status indicator codes. This process is known as compiling the MIB into the application. This process is highly vendor-specific and should be well-covered in the User’s Guide of your SNMP application. Ensure that the compilation process successfully integrates the contents of the MLXRAID.MIB file (known as the MYLEXRAID_MIB object when viewed from within the SNMP application), into the traps database.

Manual No. 775078 A-3

MYLEXRAIDMIB Object Definitions

MYLEXRAIDMIB Object Definitions

Traps

All traps are defined under this object according to the following table:

Table A-3. Traps and Trap Numbers

Trap Trap numberTraps 1-127 are physical device traps

physicalDeviceOnline 1physicalDeviceHotspare 2physicalDeviceHardError 3physicalDevicePFA 4physicalDeviceAutoRebuildStarted 5physicalDeviceManualRebuildStarted 6physicalDeviceRebuildDone 7physicalDeviceRebuildCanceled 8physicalDeviceRebuildError 9physicalDeviceRebuildNewDeviceFailed 10physicalDeviceRebuildSystemDeviceFailed 11physicalDeviceDead 12physicalDeviceFound 13physicalDeviceGone 14physicalDeviceUnconfigured 15physicalDeviceExpandCapacityStarted 16physicalDeviceExpandCapacityDone 17physicalDeviceExpandCapacityError 18physicalDeviceCommandTimeout 19physicalDeviceCommandAborted 20physicalDeviceCommandRetried 21physicalDeviceParityError 22physicalDeviceSoftError 23physicalDeviceMiscellaneousError 24physicalDeviceReset 25physicalDeviceActivespare 26physicalDeviceWarmspare 27physicalDeviceRequestSense 28[RESERVED] 29-57physicalDevicevRebuildStartFailed 58[RESERVED] 59-127

Traps 128-255 are logical drive(system device) traps

systemDeviceCheckStarted 128systemDeviceCheckDone 129systemDeviceCheckCanceled 130systemDeviceCheckError 131systemDeviceCheckSystemDeviceFailed 132

A-4 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Trap Trap numbersystemDeviceCheckPhysicalDeviceFailed 133systemDeviceOffline 134systemDeviceCritical 135systemDeviceOnline 136systemDeviceAutoRebuildStarted 137systemDeviceManualRebuildStarted 138systemDeviceRebuildDone 139systemDeviceRebuildCanceled 140systemDeviceRebuildError 141systemDeviceRebuildNewDeviceFailed 142systemDeviceRebuildSystemDeviceFailed 143systemDeviceInitializationStarted 144systemDeviceInitializationDone 145systemDeviceInitializationCanceled 146systemDeviceInitializationFailed 147systemDeviceFound 148systemDeviceGone 149systemDeviceExpandCapacityStarted 150systemDeviceExpandCapacityDone 151systemDeviceExpandCapacityError 152systemDeviceBadblock 153systemDeviceSizeChanged 154systemDeviceTypeChanged 155systemDeviceBadDataBlocksFound 156systemDeviceWriteLUNMap 157systemDeviceDataReadfromBlockinBDT 158[RESERVED] 159-255

Traps 256-271 are FMT fan trapsfmtFanFailed 256fmtFanOK 257aemiFanFailed 258fmtFanNotPresent 259[RESERVED] 260-271

Traps 272-287 are FMT power trapsfmtPowerFailed 272fmtPowerOK 273aemiPowerSupplyFailed 274fmtPowerNotPresent 275[RESERVED] 276-287

Traps 288-303 are FMT temperature trapsfmtHeatBad 288fmtHeatCritical 289fmtHeatOK 290aemiOverTemperature 291fmtHeatNotPresent 292

Table A-3. Traps and Trap Numbers

Manual No. 775078 A-5

MYLEXRAIDMIB Object Definitions

Trap Trap number[RESERVED] 293-303

Traps 304-306 are StorageWorks trapsfmtStorageWorksFailed 304fmtStorageWorksCritical 305fmtStorageWorksOK 306

Traps 307-383 are FMT enclosure traps[RESERVED] 307-319fmtEnclosureFanFailed 320fmtEnclosureFanOK 321fmtEnclosureFanNotPresent 322fmtEnclosurePowerFailed 323fmtEnclosurePowerOK 324fmtEnclosurePowerNotPresent 325fmtEnclosureHeatSensorFailed 326fmtEnclosureHeatSensorCritical 327fmtEnclosureHeatSensorOK 328fmtEnclosureHeatSensorNotPresent 329fmtEnclosureAccessCritical 330fmtEnclosureAccessOK 331fmtEnclosureAccessOffline 332[RESERVED] 333-383

Traps 384-511 are miscellaneous trapssystemStarted 384writebackError 385stateChangeTableFull 386[NOT USED] 387adapterDead 388adapterReset 389adapterFound 390adapterGone 391batteryBackupUnitFound 392batteryBackupUnitPowerLow 393batteryBackupUnitPowerOK 394[RESERVED] 395-403controllerFirmwareMismatch 404controllerBBUNotRespond 405[RESERVED] 406-413controllerECCEror 414controllerHardECCError 415[RESERVED] 416-417controllerBBUDead 418[RESERVED] 419-511

Traps 512-640 are system trapsgamSystemStarted 512systemSizeTableFull 513

Table A-3. Traps and Trap Numbers

A-6 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Trap Trap numbersystemUserLoggedIn 514systemUserLoggedOut 515[RESERVED] 516-640

Reserved Traps 641-(167)

Table A-3. Traps and Trap Numbers

Manual No. 775078 A-7

MYLEXRAIDMIB Object Definitions

Controller Information Group

This object is used to find information about any or all of the controllers present in the system.

Table A-4. Controller Information Group

Table object Data Type

Description

a2ControllerNumber1.3.6.1.4.1.1608.1.1.1.2.1.1

Integer References a particular controller by its controller number

a2OperationalState1.3.6.1.4.1.1608.1.1.1.2.1.2

Integer Operational state of the controller:Value Meaning1 Functional2 Non-Functional128 Not Present

a2FirmwareRevision1.3.6.1.4.1.1608.1.1.1.2.1.3

Display String

A displayable ASCII string containing the firmware version of the controller

a2ConfiguredChannels1.3.6.1.4.1.1608.1.1.1.2.1.4

Integer The maximum number of SCSI channels that can be configured on the controller

a2ActualChannels1.3.6.1.4.1.1608.1.1.1.2.1.5

Integer Actual number of SCSI channels present

a2MaximumLogicalDrives1.3.6.1.4.1.1608.1.1.1.2.1.6

Integer Maximum number of logical drives supported by the controller

a2MaximumTargetsPerChannel1.3.6.1.4.1.1608.1.1.1.2.1.7

Integer The maximum number of targets (SCSI IDs) supported per channel

a2MaximumTaggedRequests1.3.6.1.4.1.1608.1.1.1.2.1.8

Integer The maximum number of tagged requests per target

a2MaximumDataTransferSizePerIoRequestInK1.3.6.1.4.1.1608.1.1.1.2.1.9

Integer The maximum data transfer size supported (in KB)

a2MaximumConcurrentCommands1.3.6.1.4.1.1608.1.1.1.2.1.10

Integer The maximum number of concurrent commands that are supported.

a2RebuildRate1.3.6.1.4.1.1608.1.1.1.2.1.11

Integer The priority of rebuild versus system I/Os; Value is 0 to 50; 0 = lowest rebuild priority, 50 = highest rebuild priority

A-8 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Table object Data Type

Description

a2LogicalSectorSizeInBytes1.3.6.1.4.1.1608.1,1,1,2,1,12

Integer The logical sector (block) size in bytes (Default: 512 bytes)

a2PhysicalSectorSizeInBytes1.3.6.1.4.1.1608.1.1.1.2.1.13

Integer The physical sector (block) size in bytes (Default: 512 bytes)

a2CacheLineSizeInBytes1.3.6.1.4.1.1608.1.1.1.2.1.14

Integer The cache line size in bytes

a2CacheSizeInMb1.3.6.1.4.1.1608.1.1.1.2.1.15

Integer The memory size of the controller cache - in MB

a2CacheMemoryType1.3.6.1.4.1.1608.1.1.1.2.1.16

Integer Numerical identification of the controller cache memory type:Value Meaning1 DRAM2 EDRAM3 EDO4 SDRAM65 DRAM with parity

protection66 EDRAM with parity

protection67 EDO with parity

protection68 SDRAM with parity

protection129 DRAM with ECC

protection130 EDRAM with ECC

protection131 EDO with ECC

protection132 SDRAM with ECC

protection255 Unknown

a2EpromSizeInKb1.3.6.1.4.1.1608.1.1.1.2.1.17

Integer The flash EPROM size in KB

a2BusType1.3.6.1.4.1.1608.1.1.1.2.1.18

Integer Numerical identification of the controller’s bus type:Value Meaning1 EISA2 MCA

Table A-4. Controller Information Group

Manual No. 775078 A-9

MYLEXRAIDMIB Object Definitions

Table object Data Type

Description

3 PCI4 VESA5 ISA255 Unknown

a2ControllerClass1.3.6.1.4.1.1608.1.1.1.2.1.19

Integer The class of the controller:

Value Meaning1 RAID controller96 SCSI-SCSI128 HBA controller255 Unknown

a2ControllerModel1.3.6.1.4.1.1608.1.1.1.2.1.20

Integer Numerical identification of the controller model:Value Meaning1 DAC960E8 DAC960M16 DAC960PD17 DAC960PL18 DAC960PDU19 DAC960PE20 DAC960PG21 DAC960PJ22 DAC960PTL023 DAC960PR24 DAC960PRL25 DAC960PT26 DAC1164P27 DAC960PTL128 EXR2000P29 EXR3000P30 AR35231 AR17032 AR16096 DAC960S97 DAC960SU98 DAC960SX99 DAC960SF100 DAC960SS

Table A-4. Controller Information Group

A-10 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Table object Data Type

Description

101 DAC960FL102 DAC960LL103 DAC960FF104 FC ARRAY105 DAC960MFL106 DAC960MFF107 DAC960FFX255 Unknown

a2SystemBusNumber1.3.6.1.4.1.1608.1.1.1.2.1.21

Integer The system bus number for the controller, this value is supplied by the Operating system and may not be defilned for all operating systems.

a2SlotNumber1.3.6.1.4.1.1608.1.1.1.2.1.22

Integer The slot number where the controller resides, defined for EISA and MCA controller only.

a2InterruptVectorNumber1.3.6.1.4.1.1608.1.1.1.2.1.23

Integer The interrupt vector number being used by the controller. This value is a mapped IRQ supplied by Operating System and may not be same as the actual Interrupt Vector.

a2InterruptMode

1.3.6.1.4.1.1608.1.1.1.2.1.24

Integer Numerical identification of the interrupt mode (edge/level):

Value Meaning0 EDGE1 LEVEL255 Unknown

a2NumberOfPhysicalDevices1.3.6.1.4.1.1608.1.1.1.2.1.25

Integer The number of SCSI devices detected

a2NumberOfPhysicalDevicesOffline1.3.6.1.4.1.1608.1.1.1.2.1.26

Integer The number of SCSI devices with an operational state of DEAD

a2NumberOfLogicalDevices1.3.6.1.4.1.1608.1.1.1.2.1.27

Integer The number of logical devices currently configured

a2NumberOfLogicalDevicesCritical1.3.6.1.4.1.1608.1.1.1.2.1.28

Integer The number of logical devices in a “critical” state

a2NumberOfLogicalDevicesOffline1.3.6.1.4.1.1608.1.1.1.2.1.29

Integer The number of OFFLINE logical devices

Table A-4. Controller Information Group

Manual No. 775078 A-11

MYLEXRAIDMIB Object Definitions

Table object Data Type

Description

a2FaultManagementType1.3.6.1.4.1.1608.1.1.1.2.1.30

Integer The controller’s fault management type:Value Meaning1 AEMI2 OEM14 OEM28 OEM316 CONNER32 SAFTE64 SES0 Not Present

a2ArrayInformation1.3.6.1.4.1.1608.1.1.1.2.1.31

Display String

A displayable ASCII string containing the array information. The information is of the form: A(ch-targ ch-targ) B(ch-targ), where A,B = Array List, ch = channel number, targ = SCSI target number

a2LogicalDriveReadRequestsCount1.3.6.1.4.1.1608.1.1.1.2.1.32

Integer The total number of read requests to all logical drives

a2DataReadFromLogicalDrivesInMb1.3.6.1.4.1.1608.1.1.1.2.1.33

Integer The amount of data that was read from all logical drives in MB

a2LogicalDriveWriteRequestsCount1.3.6.1.4.1.1608.1.1.1.2.1.34

Integer The total number of write requests to all logical drives

a2DataWrittenToLogicalDrivesInMb1.3.6.1.4.1.1608.1.1.1.2.1.35

Integer The amount of data that was written to all logical drives in MB

a2LogicalDrivesReadCacheHitPercentage1.3.6.1.4.1.1608.1.1.1.2.1.36

Integer The percentage rate of read cache hits for all logical drives

a2PhysicalDriveReadRequestsCount1.3.6.1.4.1.1608.1.1.1.2.1.37

Integer The total number of read requests to all physical drives

a2DataReadFromPhysicalDrivesInMb1.3.6.1.4.1.1608.1.1.1.2.1.38

Integer The amount of data that was read from all physical drives in MB

a2PhysicalWriteRequestsCount1.3.6.1.4.1.1608.1.1.1.2.1.39

Integer The total number of write requests to all physical drives

Table A-4. Controller Information Group

A-12 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Notes:

• a2ControllerNumber is the index for any search operations against this object.

• This is a READ-ONLY object. No SET operations are allowed.• A GET operation returns information about the object whose MIB ID

is in the query.

Table object Data Type

Description

a2DataWrittenToPhysicalDrivesInMb1.3.6.1.4.1.1608.1.1.1.2.1.40

Integer The amount of data that was written to all physical drives in MB

a2StorageWorksCabinetStatusOnChannel01.3.6.1.4.1.1608.1.1.1.2.1.41

Integer StorageWorks cabinet status on channel 0

Value Meaning1 Ok2 Not Ok3 Not Present

a2StorageWorksCabinetStatusOnChannel11.3.6.1.4.1.1608.1.1.1.2.1.42

Integer StorageWorks cabinet status on channel 1

Value Meaning1 Ok2 Not Ok3 Not Present

a2StorageWorksCabinetStatusOnChannel21.3.6.1.4.1.1608.1.1.1.2.1.43

Integer StorageWorks cabinet status on channel 2

Value Meaning1 Ok2 Not Ok3 Not Present

a2BatteryBackupUnitStatus1.3.6.1.4.1.1608.1.1.1.2.1.44

Integer BBU status

0 Not Present1 Present

a2PartnerControllerNumber1.3.6.1.4.1.1608.1.1.1.2.1.45

Integer Dual Active Partner Controller Number

a2WWName1.3.6.1.4.1.1608.1.1.1.2.1.46

Display String

Controller World-Wide Name

Table A-4. Controller Information Group

Manual No. 775078 A-13

MYLEXRAIDMIB Object Definitions

• A GETNEXT operation returns the object’s information which is next to the MIB ID given in the query.

• Controller numbers start at 0.

A-14 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Logical Drive Information Group

This object is used to determine information about any or all the logical drives present in the system.

Table A-5. Logical Drive Information Group

Table object Data Type

Description

a3ControllerNumber1.3.6.1.4.1.1608.1.1.1.3.1.1

Integer References a particular controller by its controller number

a3LogicalDriveNumber1.3.6.1.4.1.1608.1.1.1.3.1.2

Integer The logical drive number

a3OperationalState1.3.6.1.4.1.1608.1.1.1.3.1.3

Integer Numerical identification of the logical drive state:Value Meaning3 ONLINE4 CRITICAL255 OFFLINE128 NotPresent

a3RaidLevel1.3.6.1.4.1.1608.1.1.1.3.1.4

Integer The RAID level selected for the logical drive0 RAID01 RAID13 RAID35 RAID56 RAID0+17 JBOD

a3WritePolicy1.3.6.1.4.1.1608.1.1.1.3.1.5

Integer Numerical identification of the write policy setting for the logical drive:Value Meaning0 WRITE THRU128 WRITE BACK

a3SizeInMb1.3.6.1.4.1.1608.1.1.1.3.1.6

Integer The logical drive capacity in MB

a3PhysicalSizeInMb1.3.6.1.4.1.1608.1.1.1.3.1.7

Integer The total physical capacity used by this logical drive in MB

a3StripeSizeInBytes1.3.6.1.4.1.1608.1.1.1.3.1.8

Integer The value of the stripe size in bytes, valid only for RAID levles 0, 5, and 6.

Manual No. 775078 A-15

MYLEXRAIDMIB Object Definitions

Notes:

• a3ControllerNumber and a3LogicalDriveNumber compose the Index for a search operation.

• This is a READ-ONLY object. No SET operations are allowed.

• A GET operation returns information about the object at the address (a3ControllerNumber/a3LogicalDriveNumber) specified in the argument.

• A GETNEXT operation returns information about the next object at the smallest address greater than the address specified in the argument.

• The lowest address of a drive (a3ControllerNumber/a3LogicalDriveNumber) is defined as 0/0, followed by 0,1.... 1/0, 1/1 and so on.

• Controller numbers start at 0. Logical drive numbers start at 0.

Table object Data Type

Description

a3PhysicalDriveMap1.3.6.1.4.1.1608.1.1.1.3.1.9

Display String

A displayable ASCII string containing the list of all physical drives that make up the logical drive. This information is provided in Channel Target combination form. For example, (0-1, 0-2, 1-3, 1-11)

a3ArrayList1.3.6.1.4.1.1608.1.1.1.3.1.10

Display String

The list of arrays across which this logical drive spans. For example, A B, etc.

a3RaidLevelString1.3.6.1.4.1.1608.1.1.1.3.1.11

Display String

RAID Level associated with Logical Drive

Table A-5. Logical Drive Information Group

A-16 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Physical Device Information Group

This object is used to find information about any or all of the physical devices present in the system.

Table A-6. Physical Device Information Group

Table object Data Type

Description

a4ControllerNumber1.3.6.1.4.1.1608.1.1.1.4.1.1

Integer References a particular controller by its controller number

a4ScsiBusId1.3.6.1.4.1.1608.1.1.1.4.1.2

Integer SCSI channel number

a4ScsiTargetId1.3.6.1.4.1.1608.1.1.1.4.1.3

Integer SCSI target number

a4ScsiLunId1.3.6.1.4.1.1608.1.1.1.4.1.4

Integer SCSI logical unit number (LUN) of the SCSI device

a4OperationalState1.3.6.1.4.1.1608.1.1.1.4.1.5

Integer Numerical identification of the physical device state:Value Meaning0 UnConfigured1 ONLINE3 REBUILDING4 INSTABORT6 NOT PRESENT8 DEAD33 HOT SPARE130 REBUILD

CANCELLEDa4VendorId1.3.6.1.4.1.1608.1.1.1.4.1.6

Display String

The SCSI device vendor ID. This is the vendor ID from the SCSI INQUIRY data.

a4ProductId1.3.6.1.4.1.1608.1.1.1.4.1.7

Display String

The SCSI device product ID. This is the product ID from the SCSI INQUIRY data.

a4ProductRevisionLevel1.3.6.1.4.1.1608.1.1.1.4.1.8

Display String

The SCSI device product revision level. This is the revision level from the SCSI INQUIRY data.

a4SizeInMb1.3.6.1.4.1.1608.1.1.1.4.1.9

Integer The physical device capacity in MB

Manual No. 775078 A-17

MYLEXRAIDMIB Object Definitions

Table object Data Type

Description

a4DeviceType1.3.6.1.4.1.1608.1.1.1.4.1.10

Integer Numerical identification of the SCSI device type. The value matches the device type value of the SCSI INQUIRY data:Value Meaning0 FIXED DISK1 TAPE2 PRINTER3 PROCESSOR4 WORM5 CDROM6 SCANNER7 MO8 CHANGER9 COMMUNICATION

DEVICE10 GRAPHICS-011 GRAPHICS-112-30 Reserved31 Unknown199 SCSI HOST204 Ctrl Channel

a4SoftErrorsCount1.3.6.1.4.1.1608.1.1.1.4.1.11

Integer The number of soft errors that occurred

a4HardErrorsCount1.3.6.1.4.1.1608.1.1.1.4.1.12

Integer The number of hard errors that occurred

a4ParityErrorsCount1.3.6.1.4.1.1608.1.1.1.4.1.13

Integer The number of parity errors that occurred

a4MiscErrorsCount1.3.6.1.4.1.1608.1.1.1.4.1.14

Integer The number of miscellaneous errors that occurred

a4ArrayList1.3.6.1.4.1.1608.1.1.1.4.1.15

Display String

The list of arrays to which this physical drive belongs. For example, A, B, etc.

a4LogicalDriveList1.3.6.1.4.1.1608.1.1.1.4.1.16

Integer The list of logical drives that depend on this physical drive. For example, 0, 1, etc.

Table A-6. Physical Device Information Group

A-18 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Notes:

• a4ControllerNumber, a4ScsiBusId, and a4ScsiTargetId comprise the Index for the search operation.

• This is a READ-ONLY object. No SET operations are allowed.

• A GET operation returns information about the object at the address (a4ControllerNumber/a4ScsiBusId/a4ScsiTargetId) specified in the argument.

• A GETNEXT operation returns information about the next object at the smallest address greater than the address specified in the argument.

• The lowest address of a device (a4ControllerNumber/a4ScsiBusId/a4ScsiTargetId) is defined as 0/0/0, followed by 0/0/1, .... 0/1/0, 0/1/1,... 1/0/0,1/0/1 and so on.

• Controller numbers start at 0. Channel numbers start at 0. Target IDs start at 0.

Manual No. 775078 A-19

MYLEXRAIDMIB Object Definitions

RAID Management Software Group

This object contains the build date and version number for the Global Array Manager driver, Disk Array Controller device driver, and SNMP agent.

Notes:

• This is a READ-ONLY object. No SET operations are allowed.

• A GET operation returns information about the object at the address specified in the argument.

• A GETNEXT operation returns information about the next object at the smallest address greater than the address specified in the argument.

Table A-7. RAID Management Software Group

Table object Data Type

Description

a5ManagementSoftwareRevision1.3.6.1.4.1.1608.1.1.1.5.1.1

Display String

A displayable string that shows the revision level of the SNMP agent

a5ManagementSoftwareBuildDate1.3.6.1.4.1.1608.1.1.1.5.1.2

Display String

A displayable string that shows the build date for the SNMP agent

a5MylexDacDeviceDriverRevision1.3.6.1.4.1.1608.1.1.1.5.1.3

Display String

A displayable string that shows the revision level of the controller device driver

a5MylexDacDeviceDriverBuildDate1.3.6.1.4.1.1608.1.1.1.5.1.4

Display String

A displayable string that shows the build date for the controller device driver

a5GamDriverRevision1.3.6.1.4.1.1608.1.1.1.5.1.5

Display String

A displayable string that shows the revision level of the Global Array Manager (GAM) driver

a5GamDriverBuildDate1.3.6.1.4.1.1608.1.1.1.5.1.6

Display String

A displayable string that shows the build date for the Global Array Manager (GAM) driver

A-20 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Logical Drive Statistics Group

This object is used to determine statistics about all logical drives configured on a controller.

Notes:

• a6ControllerNumber and a6LogicalDriveNumber compose the Index for a search operation.

• This is a READ-ONLY object. No SET operations are allowed.

• A GET operation returns information about the object at the address (a6ControllerNumber/a6LogicalDriveNumber) specified in the argument.

• A GETNEXT operation returns information about the next object at the smallest address greater than the address specified in the argument.

• The lowest address of a drive (a6ControllerNumber/a6LogicalDriveNumber) is defined as 0/0, followed by 0,1.... 1/0, 1/1 and so on.

• Controller numbers start at 0. Logical drive numbers start at 0.

Table A-8. Logical Drive Statistics Group

Table object Data Type

Description

a6ControllerNumber1.3.6.1.4.1.1608.1.1.1.6.1.1

Integer References a particular controller by its controller number

a6LogicalDriveNumber1.3.6.1.4.1.1608.1.1.1.6.1.2

Integer The logical drive number

a6ReadRequestsCount1.3.6.1.4.1.1608.1.1.1.6.1.3

Integer The total number of read requests

a6DataReadInMb1.3.6.1.4.1.1608.1.1.1.6.1.4

Integer The total amount of data that was read in MB

a6WriteRequestsCount1.3.6.1.4.1.1608.1.1.1.6.1.5

Integer The total number of write requests

a6DataWrittenInMb1.3.6.1.4.1.1608.1.1.1.6.1.6

Integer The total amount of data that was written in MB

a6ReadCacheHitPercentage1.3.6.1.4.1.1608.1.1.1.6.1.7

Integer The percentage rate of read cache hits

Manual No. 775078 A-21

MYLEXRAIDMIB Object Definitions

Physical Drive Statistics Group

This object is used to determine statistics about all physical drives configured on a controller.

Notes:

• a7ControllerNumber, a7ScsiBusId, and a7ScsiTargetId comprise the Index for the search operation.

• This is a READ-ONLY object. No SET operations are allowed.

• A GET operation returns information about the object at the address (a7ControllerNumber/a7ScsiBusId/a7ScsiTargetId) specified in the argument.

• A GETNEXT operation returns information about the next object at the smallest address greater than the address specified in the argument.

• The lowest address of a device (a7ControllerNumber/a7ScsiBusId/a7ScsiTargetId) is defined as 0/0/0, followed by 0/0/1, .... 0/1/0, 0/1/1,... 1/0/0,1/0/1 and so on.

• Controller numbers start at 0. Channel numbers start at 0. Target IDs start at 0.

Table A-9. Physical Drive Statistics Group

Table object Data Type

Description

a7ControllerNumber1.3.6.1.4.1.1608.1.1.1.7.1.1

Integer References a particular controller by its controller number

a7ScsiBusID1.3.6.1.4.1.1608.1.1.1.7.1.2

Integer SCSI channel number

a7ScsiTargetId1.3.6.1.4.1.1608.1.1.1.7.1.3

Integer SCSI target number

a7ScsiLun1.3.6.1.4.1.1608.1.1.1.7.1.4

Integer SCSI logical unit number (LUN) of the SCSI device

a7ReadRequestsCount1.3.6.1.4.1.1608.1.1.1.7.1.5

Integer The total number of read requests

a7DataReadInMb1.3.6.1.4.1.1608.1.1.1.7.1.6

Integer The total amount of data that was read in MB

a7WriteRequestsCount1.3.6.1.4.1.1608.1.1.1.7.1.7

Integer The total number of write requests

a7DataWrittenInMb1.3.6.1.4.1.1608.1.1.1.7.1.8

Integer The total amount of data that was written in MB

A-22 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Fault Management Cabinet Information Group

This object is used to obtain information about the fault management cabinet that is in use.

Table A-10. Fault Management Cabinet Information Group

Table object Data Type

Description

a8ControllerNumber1.3.6.1.4.1.1608.1.1.1.8.1.1

Integer References a particular controller by its controller number

a8ScsiBusId1.3.6.1.4.1.1608.1.1.1.8.1.2

Integer SCSI channel number

a8CabinetNumber1.3.6.1.4.1.1608.1.1.1.8.1.3

Integer The cabinet number

a8ScsiTargetId1.3.6.1.4.1.1608.1.1.1.8.1.4

Integer SCSI target number

a8ScsiLun1.3.6.1.4.1.1608.1.1.1.8.1.5

Integer SCSI logical unit number (LUN) of the SCSI device

a8CabinetType1.3.6.1.4.1.1608.1.1.1.8.1.6

Integer Numerical identification of fault management cabinet type:Value Meaning1 CONNER CR62 CONNER Smart

Cabinet3 Safte32 SAFTE64 SES255 Unknown

a8NumberOfFans1.3.6.1.4.1.1608.1.1.1.8.1.7

Integer The number of fans housed in the cabinet

a8NumberOfPowerSupplyUnits1.3.6.1.4.1.1608.1.1.1.8.1.8

Integer The number of power supply units installed

a8NumberOfHeatSensors1.3.6.1.4.1.1608.1.1.1.8.1.9

Integer The number of heat sensors

a8NumberOfDriveSlots1.3.6.1.4.1.1608.1.1.1.8.1.10

Integer The number of drive slots

a8NumberOfDoorLocks1.3.6.1.4.1.1608.1.1.1.8.1.11

Integer The number of door locks

a8NumberOfSpeakers1.3.6.1.4.1.1608.1.1.1.8.1.12

Integer The number of speakers

a8NumberOfFansCritical1.3.6.1.4.1.1608.1.1.1.8.1.13

Integer The number of fans in a “critical” state

Manual No. 775078 A-23

MYLEXRAIDMIB Object Definitions

Notes:

• a8ControllerNumber, a8ScsiBusId, and a8CabinetNumber comprise the Index for the search operation.

• This is a READ-ONLY object. No SET operations are allowed.

• A GET operation returns information about the object at the address (a8ControllerNumber/a8ScsiBusId/a8ScsiTargetId) specified in the argument.

• A GETNEXT operation returns information about the next object at the smallest address greater than the address specified in the argument.

• The lowest address of a device (a8ControllerNumber/a8ScsiBusId/a8CabinetNumber) is defined as 0/0/0, followed by 0/0/1, .... 0/1/0, 0/1/1,... 1/0/0,1/0/1 and so on.

• Controller numbers start at 0. Channel numbers start at 0. Target IDs start at 0.

Table object Data Type

Description

a8NumberOfPowerSupplyUnitsCritical1.3.6.1.4.1.1608.1.1.1.8.1.14

Integer The number of power supply units in a “critical” state

a8NumberOfHeatSensorsCritical1.3.6.1.4.1.1608.1.1.1.8.1.15

Integer The number of heat sensors in a “critical” state

a8NumberOfFansFailed1.3.6.1.4.1.1608.1.1.1.8.1.16

Integer The number of fans in the “failed” state

a8NumberOfPowerSupplyUnitsFailed1.3.6.1.4.1.1608.1.1.1.8.1.17

Integer The number of power supply units in the “failed” state

a8NumberOfHeatSensorsFailed1.3.6.1.4.1.1608.1.1.1.8.1.18

Integer The number of heat sensors in the “failed” state

Table A-10. Fault Management Cabinet Information Group

A-24 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

RAID Event Information Group

This object is used to obtain information on events that occur for any or all of the controllers. This group’s information is used to send SNMP traps to the SNMP Manager workstation.

Table A-11. RAID Event Information Group

Table object Data Type

Description

a9EventTableIndex1.3.6.1.4.1.1608.1.1.1.9.1.1

Integer The index to the Event Table

a9EventCode1.3.6.1.4.1.1608.1.1.1.9.1.2

Integer Numerical identification of the event codes for events. (For event codes, see “Traps” beginning on page A-6)

a9EventTimeStamp1.3.6.1.4.1.1608.1.1.1.9.1.3

Integer The time associated with the event. This is provided as the number of seconds since midnight, January 1, 1970.

a9ControllerNumber1.3.6.1.4.1.1608.1.1.1.9.1.4

Integer References a particular controller by its controller number

a9ChannelNumber1.3.6.1.4.1.1608.1.1.1.9.1.5

Integer SCSI channel number; valid for physical drive events and fault management events

a9TargetNumber1.3.6.1.4.1.1608.1.1.1.9.1.6

Integer SCSI target ID; valid for physical drive events

a9LunNumber1.3.6.1.4.1.1608.1.1.1.9.1.7

Integer SCSI logical unit number (LUN) of the physical device; valid for physical drive events

a9LogicalDriveNumber1.3.6.1.4.1.1608.1.1.1.9.1.8

Integer The logical drive number; valid for logical drive events

a9FmtCabinetNumber1.3.6.1.4.1.1608.1.1.1.9.1.9

Integer The fault management cabinet number; valid for fault management events

a9FanUnitNumber1.3.6.1.4.1.1608.1.1.1.9.1.10

Integer The fan unit number in the fault management cabinet; valid for fault management events

a9PowerSupplyUnitNumber1.3.6.1.4.1.1608.1.1.1.9.1.11

Integer The power supply unit number in the fault management cabinet; valid for fault management events

a9HeatSensorUnitNumber1.3.6.1.4.1.1608.1.1.1.9.1.12

Integer The heat sensor unit number

Manual No. 775078 A-25

MYLEXRAIDMIB Object Definitions

Notes:

• The value -1 in any of the object fields signifies that the field is not valid for the event being considered.

• This is a READ-ONLY object. No SET operations are allowed.

• A GET operation returns information about the object whose MIB ID is in the query.

• A GETNEXT operation returns the object’s information which is next to the MIB ID given in the query.

A-26 Global Array Manager Server Software Manual

SNMP Installation, Operation, and Definition

ASNMP

Battery Backup Unit Information Group

This object is used to obtain information about the Battery Backup Unit (BBU).

Table A-12. Battery Backup Unit Information Group

Table object Data Type

Description

a10ControllerNumber1.3.6.1.4.1.1608.1.1.1.10.1.1

Integer References a particular controller by its controller number

a10OperationalState1.3.6.1.4.1.1608.1.1.1.10.1.2

Integer Operational state of the Battery Backup Unit (BBU)Value Meaning

Integer 1 No recondition since power on

Integer 2 Recondition neededInteger 4 First warning on low

battery chargeInteger 8 Last warning on low

battery chargeInteger 16 Reconditioning

activeInteger 32 DischargingInteger 64 Fast chargingInteger 128 Low power alarmInteger 255 No battery backup

presenta10BatteryType1.3.6.1.4.1.1608.1.1.1.10.1.3

Integer The battery type

Integer 0 UnknownInteger 1 Nickel CadmiumInteger 2 NiMhInteger 3 Lithium IonInteger 254 No battery backup

presenta10CurrentPowerInHours1.3.6.1.4.1.1608.1.1.1.10.1.4

Integer Current battery power in hours

a10MaximumPowerInHours1.3.6.1.4.1.1608.1.1.1.10.1.5

Integer Maximum battery power in hours

a10ThresholdValueInHours1.3.6.1.4.1.1608.1.1.1.10.1.6

Integer Battery threshold value in hours

a10ChargeLevelInPercentage1.3.6.1.4.1.1608.1.1.1.10.1.7

Integer Current charge level of the battery (%)

Manual No. 775078 A-27

MYLEXRAIDMIB Object Definitions

Notes:

• a10ControllerNumber is the index for any search operations against this object.

• This is a READ-ONLY object. No SET operations are allowed.• A GET operation returns information about the object whose MIB ID

is in the query.• A GETNEXT operation returns the object’s information which is next

to the MIB ID given in the query.• Controller numbers start at 0.

a10Version1.3.6.1.4.1.1608.1.1.1.10.1.8

Integer The battery hardware version

a10OperationalStateString1.3.6.1.4.1.1608.1.1.1.10.1.9

Display String

Operational State of Battery Backup Unit

Table A-12. Battery Backup Unit Information Group

A-28 Global Array Manager Server Software Manual

Appendix BRAID Fault Management

BRAIDBLD

RAIDBUILD Utility OverviewThe RAIDBUILD (RAIDBLD) utility, available for all GAM Server supported operating system platforms, offers more user control over the following RAID fault management activities:

• Scanning for failed hot spare drives and/or inactive online physical devices, and defining the interval between scans.

• Changing the path and filename of the file which will hold all RAIDBLD message log information.

• Setting the device name of a console which will display all RAIDBLD message log information with an audible tone as each message is displayed.

• Performing an “automatic rebuild,” which starts a drive rebuild process as soon as a failed drive is replaced.

• Performing background “consistency checks,” specifying the start time, interval between consistency checks, and whether or not to fix errors on-the-fly.

RAIDBLD Command LineThe RAIDBLD utility file is installed during normal GAM Server installation under all supported operating systems. During installation of GAM Server, there is an instruction to modify the GAMEVENT and GAMEVLOG command lines in the system startup file to specify the IP addresses of client systems and the path and name of the message log file. Within this same startup file, the RAIDBLD command line (disabled by default) must be enabled if you wish to achieve any RAID fault management.

� NoteRAIDBLD is not supported with external controllers, such as: DACSF, DACFL, FFx, Meteor FF, etc.

Manual No. 775078 B-1

Enabling and Running RAID Fault Management (RAIDBLD)

The following RAIDBLD command line is installed during GAM Server installation:

#[path]raidbld -s 7 -S 1 -r -R 1 -t 24 -T 0 -l [path]raidbld.log [bk]

where:# : signifies that the following text line is a disabled command line or is a comment;

[path] : is the directory path to the raidbld utility file or the raidbld.log file;

[bk] : is an operating system-specific parameter which runs RAIDBLD in the background. [bk] is & for Unix operating systems and is blank for all other operating systems.

� NoteIndividual command line parameters will be discussed in a later section. The correct background run parameter [bk] will already be present in the RAIDBLD command line after GAM Server installation.

Enabling and Running RAID Fault Management (RAIDBLD)To enable RAID fault management using the RAIDBLD utility, simply remove the “#” (comment line indicator) from the beginning of the RAIDBLD command line.

Once you have removed the “#” you may wish to change one or more of the command line parameter default settings (the information after raidbld on the command line). The next section introduces the command line parameters, identifies the installed defaults, and indicates other options, if available.

B-2 Global Array Manager Server Software Manual

RAID Fault Management

BRAIDBLD

RAIDBLD Command Line Parameters

For a list of available parameters while online, type:

raidbld -? ↵

The basic structure of the RAIDBLD command line is as follows:

raidbld -[param] [value, (if required)] -[param] [value]..., etc.

Each parameter must be preceded by a dash “-”. Several parameters require a value which directly follows the parameter. Parameters and values are separated by a space.

Table C-1 beginning on the next page displays the following information for each RAIDBLD parameter:

• The parameter switch (such as -s, -R, etc.)

• Valid parameter values, as well as the default value

• An example of the use of the parameter [value]

• A description of the parameter’s function

Manual No. 775078 B-3

Enabling and Running RAID Fault Management (RAIDBLD)

Table B-1. Command Line Parameters and Their Functions

Param Value(s) / Default / Example Description

-s Values = 1,2,3,4, etc.

Default = -s 7

Example = raidbld -s 10

Define Scan Interval: Sets the number of seconds between each scan for failed devices, device state changes, controller errors, etc. The number must be an integer.

-S Values = 0 = no scan1 = scan for failed hot spares2 = scan for inactive online physical devices3 = both 1 and 2

Default = -S 1

Example = raidbld -S 3

Scan For Failed Devices: Allows scanning for failed hot spares, inactive online physical devices, or both. A value of 0 (or the absence of the -S parameter in the command line) will disable this automatic scanning.

-l Value = [path][filename]

Default = -l [path]raidbld.log

Example = raidbld -l c:\myfile.log

Log All RAIDBLD Information to a File: If you choose, you may change the default log file name, or remove the -l (lowercase L) parameter to disable logging to a file.

-c Value = [path][devicename]

Default = OFF (param not set)

Example = raidbld -c /dev/tty07

Display All RAIDBLD Information on a Console: If you choose, you may add the path and name of a console device on which the log messages will be displayed.

-r Value = none

Default = -r

Example = raidbld -r

Perform Automatic Rebuild: Initiates a rebuild automatically if a failed drive is replaced with an unconfigured, valid drive.

-R Values = 0 = fix errors1 = do not fix errors

Default = -R 1

Example = raidbld -R 0

Specify Whether or Not Errors Will Be Fixed Automatically During Consistency Check: You can specify whether automatic consistency check should fix consistency errors as it finds them, or leave errors as they are. This parameter is required in order to activate background consistency checking. Set start time and interval with the parameters below.

B-4 Global Array Manager Server Software Manual

RAID Fault Management

BRAIDBLD

Running RAIDBLD

The default RAIDBLD command line is set to do the following when RAIDBLD runs:

• Use a scan interval of seven (7) seconds [-s 7];

• Scan for failed hot spares only [-S 1];

• Perform automatic rebuilds when failed drives are replaced [-r];

• Perform automatic consistency checks beginning tonight at midnight [-T 0], every midnight [-t 24], but do not automatically fix consistency errors [-R 1];

• Log RAIDBLD messages to a specified log file, [-l [pathname] raidbld.log];

• Do NOT specify a console device to display RAIDBLD messages (-c parameter not set).

Param Value(s) / Default / Example Description

-T Values = 0 = 12:00 A.M....to...23 = 11:00 P.M.

Default = -T 0

Example = raidbld -T 19

Set Start Time For Background Consistency Check: If you wish to run automatic consistency checks, use this parameter to specify the time of day (on the hour only) to begin the first consistency check. To turn OFF the automatic consistency check function, remove the -R parameter and its value.

-t Values = 1,2,3,4, etc.

Default = -t 24

Example = raidbld -t 12

Set Interval Between Background Consistency Checks: If you wish to run multiple, ongoing consistency checks, specify the time interval (in hours) between the end of one consistency check and the start of the next one. To turn OFF the automatic consistency check function, remove the -R parameter and its value.

Table B-1. Command Line Parameters and Their Functions

Manual No. 775078 B-5

Enabling and Running RAID Fault Management (RAIDBLD)

If you accept these settings and require no changes, simply save the file and reboot the server. RAIDBLD will run automatically at system startup with the default settings.

If you wish to change one or more settings, do the following:

1. Refer to the RAIDBLD Command Line Parameter Table above and note which parameters and or values you wish to change.

2. Modify the raidbld command line to specify your options.

Modifying the RAIDBLD command line involves doing one or more of the following:

• Adding a parameter and value to the command line to turn ON a new RAIDBLD function (e.g.: Adding -c /dev/tty07 to define a display console)

• Deleting a parameter (and value, if present) to turn OFF a particular RAIDBLD function (e.g.: Removing -r to disable automatic rebuild; removing -R [value] to turn off background consistency checks; removing -l [value] to turn off RAIDBLD message logging to a file, etc.)

• Changing a parameter’s value to alter a time interval or select a different setting (e.g.: -R 1 becomes -R 0 to allow consistency errors to be fixed; -s 7 becomes -s 60 to increase the scan interval to 60 seconds; -S 1 becomes -S 3 to scan for both failed hot spares AND inactive online physical devices, etc.)

3. After modifying the RAIDBLD command line, save the file.

4. If the file was edited during GAM Server installation, complete the installation process according to instructions. If the file was edited outside of GAM installation, close the file.

5. Reboot your server. RAIDBLD will run automatically with the settings you selected.

B-6 Global Array Manager Server Software Manual

Appendix CExternal RAID Support Enabling

CEXTRAID

External RAID Support Enabling OverviewThe GAMCONFG utility is used for the following activities:

• To enable External RAID support in GAM Server. If you are using Mylex External RAID Controllers (such as the DAC960SX) connected to standard SCSI Host Bus Adapters anywhere in your configuration and you wish to use GAM to configure, monitor, and maintain disk arrays installed on these controllers, you must manually enable External RAID support.

� NoteBy default, External RAID support in GAM Server is disabled.

• Optionally, to define specific and/or a range of channels and targets to be scanned on a generic SCSI Host Bus Adapter. This allows you to direct GAM Server to scan only those channels and targets where External RAID Controllers and their disk drives reside.

GAMCONFG Command LineThe External RAID enabling function is installed during normal GAM Server installation under supported operating systems. During installation of GAM Server, there is an instruction to modify the GAMEVENT and GAMEVLOG command lines in the system startup file to specify the IP addresses of client systems and the path and name of the message log file. Within this same startup file, the GAMCONFG command line (disabled by default) is found at the bottom of the section called “SCSI - SCSI GAM support,” and must be enabled if you wish to use Mylex External RAID Controllers with GAM.

Manual No. 775078 C-1

Enabling External RAID Support (GAMCONFG)

The following GAMCONFG command line is installed during GAM Server installation:

#[path]gamconfg -c 1 -t 16 -T 1111111111111111

where:# : signifies that the following text line is a disabled command line or is a comment;

[path] : is the directory path to the gamconfg utility file.

� NoteIndividual command line parameters will be discussed in a later section.

Enabling External RAID Support (GAMCONFG)To enable External RAID support and use the default settings, simply remove the “#” (comment line indicator) from the beginning of the GAMCONFG command line.

Once you have removed the “#” you may wish to change one or more of the command line parameter default settings (the information after gamconfg on the command line). The next section introduces the command line parameters, identifies the installed defaults, and indicates other options, if available.

GAMCONFG Command Line Parameters

Within the system startup file which contains the GAMCONFG command line (called SCSI - SCSI GAM support), you will find a brief description of the command line parameters and how they are used. Refer to that description or to the information in this appendix for details while configuring the GAMCONFG command line.

C-2 Global Array Manager Server Software Manual

External RAID Support Enabling

CEXTRAID

The basic structure of the GAMCONFG command line is as follows:

gamconfg -[param] [value(s)] -[param] [value(s)]..., etc.

Each parameter must be preceded by a dash “-”. Parameters require a value which directly follows the parameter. Parameters and values are separated by a white space.

Table D-1 beginning on the next page displays the following information for each GAMCONFG parameter:

• The parameter switch (such as -c, -T, etc.)

• Valid parameter values, as well as the default value

• Examples of the use of the parameter [value]

• A description of the parameter’s function

Manual No. 775078 C-3

Enabling External RAID Support (GAMCONFG)

Table C-1. Command Line Parameters and Their Functions

Param Value(s) / Default / Example Description

-c Values = 1,2,3...

Default = -c 1

Examples:

gamconfg -c 1

(scans 1 channel, which is channel 0)

gamconfg -c 3

(scans 3 channels, which are channels 0, 1, and 2)

Define Max Channels to Scan: Defines a range of channels that will be scanned on the generic controller beginning with channel 0. The number must be an integer.

-C Values = 1 = scan0 = do not scan

Default = N/A

Examples:

gamconfg -C 100

(do not scan channel 0, do not scan channel 1, scan channel 2)

gamconfg -C 01

(scan channel 0, do not scan channel 1)

Define Specific Channels to Scan: Defines specific channels that will be scanned on the generic controller. Each placeholder in the value represents a specific channel, with the right-most placeholder representing channel 0. The value at each position determines whether that channel will be scanned (1) or not scanned (0).

-t Values = 1,2,3...

Default = -t 16

Examples:

gamconfg -t 16

(defines 16 targets, which are all target IDs from 0 through 15)

gamconfg -t 5

(defines 5 targets, which are target IDs 0, 1, 2, 3, and 4)

Define Max Targets to Scan: Defines a range of targets that can be scanned on the generic controller beginning with target ID 0. The number must be an integer.

C-4 Global Array Manager Server Software Manual

External RAID Support Enabling

CEXTRAID

Running GAMCONFG

The default GAMCONFG command line is set to do the following when GAMCONFG is enabled:

• Scan only channel 0 of the SCSI HBA [-c 1];

• Defines 16 targets that can be scanned (IDs 0 through 15) [-t 16];

• Of the 16 total target IDs, scan all target IDs.[-T 1111111111111111]

If you accept these settings and require no changes, simply save the file and reboot the server. GAMCONFG will run automatically at system startup with the default settings.

-T Values = 1 = scan0 = do not scan

Default = -T 1111111111111111

Examples:

gamconfg -T 1111111101111111

(scan targets 0 through 6, do not scan target 7a, scan targets 8 through 15)

gamconfg -T 00110

(do not scan target 0, scan targets 1 and 2, do not scan targets 3 and 4)

Define Specific Targets to Scan: Defines specific target IDs that will be scanned on the generic controller. Each placeholder in the value represents a specific target ID, with the right-most placeholder representing target ID 0. The value at each position determines whether that target will be scanned (1) or not scanned (0).

a. Target ID 7 is usually the target ID of the SCSI Host Bus Adapter itself and need not be scanned unless a different target ID is used for the HBA.

Table C-1. Command Line Parameters and Their Functions

Manual No. 775078 C-5

Enabling External RAID Support (GAMCONFG)

If you wish to change one or more settings, do the following:

1. Refer to the GAMCONFG Command Line Parameter Table and note which parameters and or values you wish to change.

2. Modify the GAMCONFG command line to specify your options.

3. After modifying the command line, save the file.

4. If the file was edited during GAM Server installation, complete the installation process according to instructions. If the file was edited outside of GAM installation, close the file.

5. Reboot your server. GAMCONFG will run automatically to enable External RAID support with the settings you selected.

C-6 Global Array Manager Server Software Manual

Appendix DThe MYLEXDRV.SIZ File

DDRVSIZE

Drive Size Limits OverviewOne of the common characteristics of disk drives grouped into disk arrays or RAID groups is that each disk drive in the logical group is generally the same size (capacity). While it is not strictly required that this be so, it is most beneficial for the following reasons:

• If physical disk drives defined in a logical group are of different sizes, the drive initialization process sees to it that the usable capacity of each physical disk drive will be the same. This can lead to capacity being unused or unavailable for use, and wasted capacity usually means wasted cost.

EXAMPLE: If three physical drives are of capacity 3 GB, 3 GB, and 4 GB respectively, and they are grouped together into one RAID 5 logical drive, initialization will result in three drives using 3 GB of capacity each. One GB on the 4 GB drive is unused.

• If hot spare (standby drives) is to be used in a configuration to take over for a failed drive, the hot spare drive’s capacity must be equal to or greater than the capacity of the smallest drive in the configuration. Therefore, using physical disk drives of different capacities can actually interfere with proper drive rebuild operation.

When using multiple physical disk drives from the same drive vendor, it’s usually not difficult to ensure that the drives to be used together in a logical group all have the same capacity. The challenge arises when attempting to use disk drives of similar capacity from multiple disk drive vendors.

For example, a 4 GB disk drive from a particular vendor may actually be 4.01 GB. A 4 GB drive from another vendor may actually be 4.12 GB. Even though the drives capacities are similar, they are not exact, and the problems described above can occur. If the 4.01 GB drive from Vendor A is used as a hot spare in a RAID 5 array consisting of 4.12 GB drives from Vendor B, the rebuild process will fail because the hot spare drive is smaller than the size of the drive it’s trying to replace.

Manual No. 775078 D-1

GAMSETSZ Command Line

The Drive Size Limits function provides a resolution to this problem. You can manually set the maximum, usable size of particular disk drives from particular vendors such that they are equivalent across vendors’ drives.

EXAMPLE: Vendor A’s 4.01 GB drive can be manually set to 4 GB. Likewise, Vendor B’s 4.12 GB drives can also be manually set to 4 GB. For GAM, the capacities of the drives would be considered equivalent and no complications should arise when using hot spares or when mixing drives from different vendors in a single logical group.

GAMSETSZ Command LineThe Mylex Drive Size Limit function is installed during normal GAM Server installation under supported operating systems. During installation of GAM Server, there is an instruction to modify the GAMEVENT and GAMEVLOG command lines in the system startup file to specify the IP addresses of client systems and the path and name of the message log file. Within this same startup file, the gamsetsz command line (enabled by default to use settings stored in the file MYLEXDRV.SIZ) is found at the bottom of the section called “DRIVE SIZE LIMIT.”

The following gamsetsz command line is installed during GAM Server installation:

[path]gamsetsz -f [path]mylexdrv.siz &

where:[path] : is the directory path to the GAMSETSZ utility file;

& : indicates that you may include additional drive size settings filenames after the ‘&’ (perhaps from a drive vendor) which also define specific drive size information.

� NoteIf you have particular SIZ files available from one or more drive vendors, add the filename(s) to the end of the gamsetsz command line. Refer to the next section for information on modifying the contents of the Mylex-supplied SIZ file (MYLEXDRV.SIZ).

D-2 Global Array Manager Server Software Manual

The MYLEXDRV.SIZ File

DDRVSIZE

Using the MYLEXDRV.SIZ FileThe gamsetsz command line makes reference to the MYLEXDRV.SIZ file. This is a Mylex-supplied text file containing instructions for defining drive size limits. It is also the text file in which you actually store the drive size information that will be read by GAMSETSZ and used in GAM configurations.

� NoteWe recommend that you print and/or view online the MYLEXDRV.SIZ file at your earliest convenience. The structure of a drive size limit data line is somewhat complex, and advance study of the byte definitions can be helpful.

A summary of the byte definitions is provided in the next section of this appendix.

MYLEXDRV.SIZ Byte Definitions

The MYLEXDRV.SIZ file contains detailed byte definitions for construction of data lines to be read by GAMSETSZ. Constructing a valid data line consists of providing the requested information correctly at each of the appropriate byte positions in the data line.

Use only what is referred to as the “New Format.”

The basic structure of a New Format data line is as follows:

[+/-][vendor ID][product ID][revision] [capacity][units][comments]

Table D-1 beginning on the next page displays the following information:

• The byte position range for a data item (such as 0..0, 1..28)

• The number of bytes used for the data item

• Valid values for the data item

• Brief description of the data item.

Manual No. 775078 D-3

Using the MYLEXDRV.SIZ File

Refer to the contents of the MYLEXDRV.SIZ text file for examples of correctly-formatted data lines. Enter new data lines there as well.

Table D-1. Byte Positions and Their Functions

Byte Range

# Bytes Used

Byte Values Description

0..0 1 + = Adds the new entry

- = Removes old entries

Add/Remove Entry: First character in the data line indicates whether this is a new or changed entry for the GAM driver (+), or whether an entry is to be removed or disabled (-) while keeping its settings available for future use.

1..28 28 1..8 = Specific vendor name up to eight characters in length

9..24 = Product name up to 16 characters in length.

25..28 = Revision identifier up to four characters in length

Use “?” as a wildcard character.

Vendor/Product/Revision: These 28 bytes are used to specify the drive vendor, particular product ID, and revision using the format defined in the SCSI specification. You will need to obtain this information from your drive vendor or a supplied vendor SIZ file.

29..29 1 Any character Separator: One character as a separator. This can be a space, a “:” or any character you choose.

30..39 10 0 through 9999999999 Capacity as Integers: Up to 10 bytes are used to specify the capacity as a whole number using integers only. The value assigned to the capacity numbers depends on the units selected in the next byte.

40..40 1 g, G = Gigabytes (GB)

m, M = Megabytes (MB)

k, K = Kilobytes (KB)

Capacity Units: One character defines the units of the number in the previous 10 bytes

41..nn variable Any characters Comments: Additional bytes can be used for comments.

D-4 Global Array Manager Server Software Manual

Appendix EGAMEVENT

EGAMEVT

IntroductionGAMEVENT refers to the concept of “Event Notification” in Global Array Manager. Event Notification involves the following:

1. The Global Array Manager Server (GAM Server) runs on the server computer in which the Mylex controllers and third-party disk drives are installed. When an informational event or error occurs, GAM Server generates an “event.”

2. These events can be sent to client workstations running Global Array Manager Client (GAM Client) for display in GAM Client’s Log Information Viewer when the particular server is accessed.

In order to do this, a command line in the GAM Server configuration file must be modified to enable event logging to clients, AND to identify the client workstations by IP address or name.

3. Events generated by GAM Server can also be saved to a log file (GAMEVLOG.LOG, by default), which is stored on the system running GAM Server and can be viewed or printed later.

In order to do this, another command line in the GAM Server configuration file must be enabled to generate the event log file. The name of the log file or its path can also be changed if desired.

This appendix discusses how GAMEVENT works for various operating systems.

Manual No. 775078 E-1

NetWare

NetWare

Enabling Event Notification

To enable event notification to GAM clients, both local and remote, edit the LOAD GAMEVENT command line in the AUTOEXEC.NCF file.

1. Open the AUTOEXEC.NCF configuration file in a text editor.

2. Navigate to the command line of the configuration file called #LOAD GAMEVENT.

#LOAD GAMEVENT -h <enter client ip address>

3. Replace <enter client ip address> with a desired system name or IP address.

For example:

#LOAD GAMEVENT -h 10.97.49.189 -h fabd_test

where: -h <address> sets address as a receiver of events. Address may be an IP address or a network system name.

4. Additional entries require that you extend the command line. Type -h then an IP address or system name for each additional entry you need.

� NoteThe argument list is limited to 1028 bytes. Therefore, there is a practical maximum of about 50 event notification addresses. If you need to add more event notification addresses than can fit on one line, add a second line and continue adding IP addresses or system names preceded by the '-h' switch.

5. Delete the comment marker ‘#’ from the command line to enable event notification:

LOAD GAMEVENT -h 10.97.49.189 -h fabd_test

E-2 Disk Array Controller Software Kit User’s Manual

GAMEVENT

EGAMEVT

Enabling a GAM Event Log File

1. Navigate to the section of the AUTOEXEC.NCF file called #LOAD GAMEVLOG.

#LOAD GAMEVLOG -f sys:\public\gamevlog.log

2. If necessary, delete the comment marker ‘#’ from the command line to enable event logging to a file:

LOAD GAMEVLOG -f sys:\public\gamevlog.log

3. The file shown (gamevlog.log) is the default file name for the GAM event log. If you want to change this file name, replace “gamevlog” with your desired log file name.

4. The file path shown (sys:\public\) is the default file path for the GAM event log. If you want to change this path, replace “sys:\public\” with your desired file path name.

The log file will be saved to the appropriate directory.

Saving and Restarting

1. Save the .NCF file in your text editor.

2. Restart your system to start the GAM Server service and activate event notification to the specified IP addresses or system names.

� NoteTo start the event notification and/or logging without restarting the system, type the command with the parameters at the command prompt.

Manual No. 775078 E-3

Windows NT and Windows 2000

Windows NT and Windows 2000

Enabling Event Notification

To enable event notification to GAM clients, both local and remote, edit the GAMEVENT command line in the GAMSCM.INI file.

1. Open the GAMSCM.INI configuration file in a text editor.

2. Navigate to the section of the configuration file called GAMEVENT.

#gamevent.exe -k 119 -s7 -p 158 -h host1 -h host2

3. Replace host1 and host2 with a desired system name or IP address.

For example:

#gamevent.exe -k 119 -s7 -p 158 -h 192.9.11.246 -h anyname

where: -h <address> sets address as a receiver of events. Address may be an IP address or a network system name.

Some systems may already be identified in the GAMEVENT command line, either because they were previously identified in your existing GAMSCM.INI file, or because they were automatically registered when you entered IP addresses or system names during GAM Server installation.

� NoteIt is recommended NOT to change the default setting for the these options: -k 119 -s7 -p158.

4. Additional entries require that you extend the command line. Type -h then an IP address or system name for each additional entry you need.

� NoteThe argument list is limited to 1028 bytes. Therefore, there is a practical maximum of about 50 event notification addresses. If you need to add more event notification addresses than can fit on one line, add a second line and continue adding IP addresses or system names preceded by the '-h' switch.

5. Delete the comment marker ‘#’ from the command line to enable event notification:

gamevent.exe -k 119 -s7 -p 158 -h 192.9.11.246 -h anyname

E-4 Disk Array Controller Software Kit User’s Manual

GAMEVENT

EGAMEVT

Enabling a GAM Event Log File

1. Navigate to the section of the GAMSCM.INI file called GAMEVENT LOG.

#gamevlog.exe -f .\gamserv\gamevlog.log -s 0

2. If necessary, delete the comment marker ‘#’ from the command line to enable event logging to a file:

gamevlog.exe -f .\gamserv\gamevlog.log -s 0

3. The file shown (gamevlog.log) is the default file name for the GAM event log. If you want to change this file name, replace “gamevlog” with your desired log file name.

4. The file path shown (.\gamserv\) is the default file path for the GAM event log. If you want to change this path, replace “.\gamserv\” with your desired file path name.

The log file will be saved to the appropriate directory.

Saving and Restarting

1. Save the .INI file in your text editor.

2. Restart your system to start the GAM Server service and activate event notification to the specified IP addresses or system names.

Manual No. 775078 E-5

SCO UNIX and UnixWare

SCO UNIX and UnixWare

Enabling Event Notification

To enable event notification to GAM clients, both local and remote, edit the GAMEVENT command line in the S99GAM file.

1. Open the S99GAM configuration file in a text editor.

2. Navigate to the section of the configuration file called GAMEVENT.

#/usr/bin/gamevent -k 119 -s7 -p 158 -h gamclient1-h gamclient2 -h gamclient3 &

3. Replace gamclient1 gamclient2 gamclient3 with a desired system name or IP address. For example:

#/usr/bin/gamevent -k 119 -s 7 -p 158 -h 10.97.49.189-h 10.97.49.190 -h fabd_test

where: -h <address> sets address as a receiver of events. Address may be an IP address or a network system name.

� NoteIt is recommended NOT to change the default setting for the these options: -k 119 -s7 -p158.

4. Additional entries require that you extend the command line. Type -h then an IP address or system name for each additional entry you need.

� NoteThe argument list is limited to 1028 bytes. Therefore, there is a practical maximum of about 50 event notification addresses. If you need to add more event notification addresses than can fit on one line, add a second line and continue adding IP addresses or system names preceded by the '-h' switch.

5. Delete the comment marker ‘#’ from the command line to enable event notification:

/usr/bin/gamevent -k 119 -s7 -p 158 -h 10.97.49.189-h 10.97.49.190 -h fabd_test

E-6 Disk Array Controller Software Kit User’s Manual

GAMEVENT

EGAMEVT

Enabling a GAM Event Log File

1. Navigate to the section of the S99GAM file called GAMEVENT LOG.

#/usr/bin/gamevlog -f /etc/log/gamevlog.log &

2. If necessary, delete the comment marker ‘#’ from the command line to enable event logging to a file:

/usr/bin/gamevlog -f /etc/log/gamevlog.log &

3. The file shown (gamevlog.log) is the default file name for the GAM event log. If you want to change this file name, replace “gamevlog” with your desired log file name.

4. The file path shown (/etc/log/) is the default file path for the GAM event log. If you want to change this path, replace “/etc/log/” with your desired file path name.

The log file will be saved to the appropriate directory.

Saving and Restarting

1. Save the modified S99GAM file and exit.

2. Reboot the system using the following command from the root directory (match case exactly as shown):

shutdown -y -i6 -g0 ↵

Manual No. 775078 E-7

Solaris

Solaris

Enabling Event Notification

To enable event notification to GAM clients, both local and remote, edit the GAMEVENT command line in the S99GAM file.

1. Open the S99GAM configuration file in a text editor.

2. Navigate to the section of the configuration file called GAMEVENT.

#/usr/opt/MYLXgam/bin/gamevent -k 119 -s7 -p 158 -h gamclient1-h gamclient2 -h gamclient3 &

3. Replace gamclient1 gamclient2 gamclient3 with a desired system name or IP address. For example:

#/usr/opt/MYLXgam/bin/gamevent -k 119 -s 7 -p 158-h 10.97.49.189 -h 10.97.49.190 -h fabd_test

where: -h <address> sets address as a receiver of events. Address may be an IP address or a network system name.

� NoteIt is recommended NOT to change the default setting for the these options: -k 119 -s7 -p158.

4. Additional entries require that you extend the command line. Type -h then an IP address or system name for each additional entry you need.

� NoteThe argument list is limited to 1028 bytes. Therefore, there is a practical maximum of about 50 event notification addresses. If you need to add more event notification addresses than can fit on one line, add a second line and continue adding IP addresses or system names preceded by the '-h' switch.

5. Delete the comment marker ‘#’ from the command line to enable event notification:

/usr/opt/MYLXgam/bin/gamevent -k 119 -s7 -p 158-h 10.97.49.189 -h 10.97.49.190 -h fabd_test

E-8 Disk Array Controller Software Kit User’s Manual

GAMEVENT

EGAMEVT

Enabling a GAM Event Log File

1. Navigate to the section of the S99GAM file called GAMEVENT LOG.

#/usr/opt/MYLXgam/bin/gamevlog -f /usr/opt/MYLXgam/log/gamevlog.log &

2. If necessary, delete the comment marker ‘#’ from the command line to enable event logging to a file:

/usr/opt/MYLXgam/bin/gamevlog -f /usr/opt/MYLXgam/log/gamevlog.log &

3. The file shown (gamevlog.log) is the default file name for the GAM event log. If you want to change this file name, replace “gamevlog” with your desired log file name.

4. The file path shown (/usr/opt/MYLXgam/log/) is the default file path for the GAM event log. If you want to change this path, replace “/usr/opt/MYLXgam/log/” with your desired file path name.

The log file will be saved to the appropriate directory.

Saving and Restarting

1. Save the modified S99GAM file and exit.

2. Reboot the system using the following command from the root directory (match case exactly as shown):

shutdown -y -i6 -g0 ↵

Manual No. 775078 E-9

Linux

Linux

Enabling Event Notification

To enable event notification to GAM clients, both local and remote, edit the GAMEVENT command line in the Gam file to remove the initial comment marker.

To enable the Event Comment Line, follow these steps:

1. Log in as root.

2. Stop the GAM Server, type:

/etc/rc.d/init.d/Gam stop

3. Using a text editor such as gnotebook+, open the Gam file located in the following path:

/etc/rc.d/init.d/Gam

4. Navigate to the section of the file called GAMEVENT.

5. Near the bottom of this section you will see a command line such as the following (the command line parameters may differ, especially if IP addresses or node names were previously added):

#/usr/bin/gamevent -k 119 -s 7 -p 158 -h host1 -h host2 &

6. Replace host1 and host2 with a desired DNS_NAME or IP address.

For example:

#/usr/bin/gamevent -k 119 -s 7 -p 158 -h 10.97.49.189-h 10.97.49.190 -h fabd_test &

where: -h <address> sets address as a receiver of events. Address may be an IP address or a network node name.

7. Additional entries require that you extend the command line. Type -h then an IP address or node name for each additional entry you need.

E-10 Disk Array Controller Software Kit User’s Manual

GAMEVENT

EGAMEVT

� NoteThe argument list is limited to 1028 bytes. Therefore, there is a practical maximum of about 50 event notification addresses. If you need to add more event notification addresses than can fit on one line, add a second line and continue adding IP addresses or node names preceded by the '-h' switch.

8. Save the Gam file in your text editor.

9. Delete the comment marker ‘#’ from the command line to enable event notification:

/usr/bin/gamevent -k 119 -s 7 -p 158 -h 10.97.49.189-h 10.97.49.190 -h fabd_test &

Enable GAM Event Logging

To enable event logging, follow these steps:

1. Navigate to the section of the file called GAMEVENT LOG.

#/usr/bin/gamevlog -f /var/log/gamevlog.log &

where: -f sets the event log file name

2. If necessary, delete the comment marker ‘#’ from the command line to enable event logging:

/usr/bin/gamevlog -f /var/log/gamevlog.log &

3. The file shown (gamevlog.log) is the default file name for the GAM log. If you need to change this file name replace “gamevlog” with your desired log file name.

4. The file path shown (/var/log/) is the default file path for the GAM event log. If you want to change this path, replace “/var/log/” with your desired file path name.

The log file will be saved to the appropriate directory.

Manual No. 775078 E-11

Saving and Restarting

1. Save the modified Gam file and exit.

2. Start the Global Array Manager Server Service and activate event logging and notification to the specified IP addresses or node names:

/etc/rc.d/init.d/Gam start

Additional GAMEVENT ParametersIt is recommended not to change the default setting for the following options:

-k 119 -s 7 -p 158

where:

-k <seconds>: Sets the “heart beat” frequency. An “I'm alive” message is sent every 'seconds' period. The default is 0 which means no heartbeat. In that case if the server goes down the client will not know it until the user does something to make the client interact with the server.

-s <seconds>: Sets the polling rate. Each controller is polled for new events every seconds period. Default is 7.

-p <port>: Sets the port number for event reporting. Used only by special proprietary programs. The value must not be changed for normal programs. Default is 158.

E-12 Disk Array Controller Software Kit User’s Manual

GAMEVENT

EGAMEVT

GAMEVENT LOG OptionsThe server sends event activity (EVENT LOG) to other hosts computers, which can be another server or a client system. Events can be written to a file and/or to your local terminal screen. There are two options associated with the GAMEVENT LOG.

Usage:

-f File : : Sets the event log file name

Note: The event log file will be created in the

%SystemRoot%\system32\gamserv directory

� NoteOption -s is valid for only Windows NT and Windows 2000.

-s Value : : Sets the Severity Level to report.

Value 0 = Critical

1 = Serious

2 = Error

3 = Warning

4 = Information

NOTE: If a parameter is not specified, no information will be reported.

gamevlog.exe -f .\gamserv\gamevlog.log -s 0

Manual No. 775078 E-13

GAMEVENT LOG Options

E-14 Disk Array Controller Software Kit User’s Manual