geoceramic researches S.r.l. Iscritto all'Albo dei Laboratori Qualificati (art. 4 legge 46/82) Decreto del Ministero dell'Università e della Ricerca Scientifica e Tecnologica del 25/03/1990. Via Bacchello, 9 40050 Monte San Pietro tel. (0)51/676.17.38 (Bologna) - ITALY fax. (0)51/676.17.36 e-mail [email protected] TEST REPORT RdP N°: DATE n° 15471 IT-56733 Responsabile delle Prove RPR Spett.le CERAMICHE ASCOT S.p.A. 665/10-003 STABILIMENTO GRES Via Statale 569, 167/a 26/10/2010 41050 SOLIGNANO MO NORM DIN 51130 Determination of anti-slippery characteristic Work’s zone with high risk of slippery Procedure of test walking – inclined platform. The test regard work’s zone with high risk of slippery; the procedure it previews a slanted plan that it comes covered from the subject participants to the test, whose surface is paved with the material in object, preventively greased with having oil 10 viscosity SAE W 30. During the execution one determines if the material in examination can be suitable for puts down it in specific atmospheres of job. The medium degree of inclination correspondent to the feeling of insecurity of the operator who walks on the plan, defines the classification of the material in one of the five groups that serve like parameter in order to establish the effectiveness degree anti-slippery. Samples arrived at 20/10/2010 (sampling executed by Commitment) DESCRIPTION TILES : 50x50 cm - LINEA : - TYPE: “DWAS520 MORNING GOLD” Start test : 25/10/2010 End test : 25/10/2010 Slide angle : 18,3° Classification : R10 LEGEND: Total of the medium values Group classification from 6° to 10° R 9 over 10° until 19° R 10 over 19° until 27° R 11 over 27° until 35° R 12 over 35° R 13

geoceramic researches S.r.l. - Dom Ceramiche · 2016-06-21 · weight was placed on the block of wood. Using a dynamometer, the force in pounds required to cause the test assembly

  • Upload
    vannhu

  • View
    214

  • Download
    0

Embed Size (px)

Citation preview

geoceramic researches S.r.l.

Iscritto all'Albo dei Laboratori Qualificati (art. 4 legge 46/82) Decreto del Ministero dell'Università e della Ricerca Scientifica e Tecnologica del 25/03/1990.

Via Bacchello, 9 40050 Monte San Pietro tel. (0)51/676.17.38 (Bologna) - ITALY fax. (0)51/676.17.36 e-mail [email protected]

TEST REPORT RdP N°: DATE

n° 15471 IT-56733

Responsabile delle Prove RPR

Spett.le CERAMICHE ASCOT S.p.A. 665/10-003 STABILIMENTO GRES Via Statale 569, 167/a 26/10/2010 41050 SOLIGNANO MO

NORM DIN 51130

Determination of anti-slippery characteristic Work’s zone with high risk of slippery

Procedure of test walking – inclined platform. The test regard work’s zone with high risk of slippery; the procedure it previews a slanted plan that it comes covered from the subject participants to the test, whose surface is paved with the material in object, preventively greased with having oil 10 viscosity SAE W 30. During the execution one determines if the material in examination can be suitable for puts down it in specific atmospheres of job. The medium degree of inclination correspondent to the feeling of insecurity of the operator who walks on the plan, defines the classification of the material in one of the five groups that serve like parameter in order to establish the effectiveness degree anti-slippery. Samples arrived at 20/10/2010 (sampling executed by Commitment) DESCRIPTION TILES : 50x50 cm - LINEA : -

TYPE: “DWAS520 MORNING GOLD” Start test : 25/10/2010 End test : 25/10/2010 Slide angle : 18,3° Classification : R10 LEGEND: Total of the medium values Group classification from 6° to 10° R 9 over 10° until 19° R 10 over 19° until 27° R 11 over 27° until 35° R 12 over 35° R 13

geoceramic researches S.r.l.

Iscritto all'Albo dei Laboratori Qualificati (art. 4 legge 46/82) Decreto del Ministero dell'Università e della Ricerca Scientifica e Tecnologica del 25/03/1990.

Via Bacchello, 9 40050 Monte San Pietro tel. (0)51/676.17.38 (Bologna) - ITALY fax. (0)51/676.17.36 e-mail [email protected]

TEST REPORT RdP N°: DATE

n° 15471 IT-56733

Responsabile delle Prove RPR 

Spett.le CERAMICHE ASCOT S.p.A. 746/10-001 STABILIMENTO GRES Via Statale 569, 167/a 29/11/2010 41050 SOLIGNANO MO

ASTM C 1028 NORM

DETERMINATION OF STATIC COEFFICIENT OF FRICTION (test method for evaluating the static friction’s coefficient of ceramic tile and other like surfaces by the horizontal

dynamometer pull meter method, ASTM C 1028) A book of wood with a 3”x3”x1,8” section of standard neolite cement liner attached was placed on the surface to be test. A weight was placed on the block of wood. Using a dynamometer, the force in pounds required to cause the test assembly to slip parallel to the test surface was measured. Four measurements were taken on each of three test surfaces, each measurements perpendicular to the previous one. The twelve measurements thus obtained were averaged to obtain the static coefficient of friction for each test conditions.

Samples arrived at 26/11/2010 (sampling executed by Commitment) DESCRIPTION TILES : 33x33 cm

TYPE: “DWAS020 MORNING GOLD” Start test : 29/11/2010 End test : 29/11/2010 REFERENCE VALUES (The Ceramic Tile Institute identities tile in the following 3 categories): 1. Anti-slip (> 0,60) 2. Conditionally Slip resistant (0,50÷0,60) 3 Questionable (< 0,50)

Sample Position Position Position Position Average C.O.F.N° N E S W (Kg) (*)

Dry neolite1 15,9 15,8 16,1 16,2

Dry neolite2 16,7 16,5 17,5 16,3

Dry neolite3 16,3 16,0 16,4 16,1 16,3 0,70

Wet neolite1 16,4 16,8 16,7 16,9

Wet neolite2 16,9 16,3 16,5 16,0

Wet neolite3 16,2 16,0 15,8 16,0 16,4 0,61

(*) Coefficient of friction; neolite correction factor applied

Dry Neolite average C.O.F. (*) 0,70

Wet Neolite average C.O.F. (*) 0,61

Test conditions

Bologna September 27, 2010

Dom Ceramiche

Strada Statale 569, 167/A

41050 Solignano

SUBJECT: Measurement of radioactivity concentration.

Test Report n. 3622.

Please find attached to this letter the Test Report n. 3622 concerning radioactivity

measurements conducted as previously established.

According to the information reported in “Radiation Protection 112”, edited by European Com-

mission, and Standard GB6566-2001 of People’s Republic of China, the indexes in use for

evaluating the safety requirements of building materials used in a new building are:

I = Ath/200+ARa/300+AK/3000

for the Rule edited by European Commission;

Iγ (External exposure index) = ATh/260+ARa/370+AK/4200

IRa (Internal exposure index) = ARa/200

for the Rule GB6566 of People’s Republic of China, where ATh, ARa, AK, are the concentration

activities, expressed in Bq/kg, of 232Th, 226Ra and 40K, respectively.

_______________________________________________

U-Series Srl - Via Ferrarese 131 - 40128 BolognaTel. 051 0875113/4 - Fax. 051 0875110

E-mail [email protected] - http://www.u-series.com

For European Certification the values that the indexes should not exceed are the following:

- Exemption Value I ≤ 0,5: this value results, in certain circumstances, an excess dose

of 0.3 mSv per year. Materials below this index can be considered free of any restriction

in according to amount and area of use;

- Control value I ≤ 1 : this value results, in certain circumstances, an excess dose of

1.0 mSv per year compared to natural background. Values above 1.0 mSv per year

must be taken into accounts in terms of health protection.

Instead chinese certification take following requirements:

- Class A : Iγ < 1,3 and IRa < 1,0 for external and internal exposure index respectively;

- Class B: Iγ < 1,9 and IRa < 1,3 for external and internal exposure index respectively.

On the basis of performed measurements and with reference to the attached Test Report, fol-

lowing results are obtained on:

Sample Description Report N. IRP112IGB6566

Iγ IRa

Piastrella Ceramica Dwas

520 Morning Gold3622 0,720 ± 0,019 0,552 ± 0,015 0,345 ± 0,009

where uncertainties are calculated at two standard deviations. For more information on certi -

ficate is reported measurement of 137Cs.

Ing. Massimo Esposito

Qualified Expert in radiation protection n. 572

_______________________________________________

U-Series Srl - Via Ferrarese 131 - 40128 BolognaTel. 051 0875113/4 - Fax. 051 0875110

E-mail [email protected] - http://www.u-series.com

RADIOACTIVITY CONCENTRATION MEASUREMENTTEST REPORT N. 3622

Printing date: 27 September 2010Petitioner:Dom CeramicheStrada Statale 569, 167/A 41050 SolignanoSample description:Piastrella Ceramica Dwas 520 Morning GoldManufacturer:Dom CeramicheStrada Statale 569, 167/A 41050 SolignanoSampling details:Sampling date: Not Defined Sampling mode: By petitionerReception date: 27 July 2010 Reception mode: ExpeditionStandard procedures:

Results:Date of analysis: 10 September 2010 Analysis code: V3622

RadionuclideEnergy Concentration Statistical Inaccuracy Detection Limit (keV) (Bq/kg) (Bq/kg) (Bq/kg)295,22 72 4 5351,99 68 3 3609,32 69 4 41120,28 70 8 91764,51 70 8 9

--- 69,0 1,9 3,0338,40 64 7 9911,07 54 5 5968,90 58 6 7

--- 58 3 5--- 58 3 5

238,63 61 2 2583,1 58 4 4

--- 60 2 2661,62 <1,5 0 1,51460,75 610 30 20

Radioactivity Index (Standard GB6566-2001 of People's Republic of China)

Measured value Reference valuesClass A Class B

External Exposure Index (Iγ): I = 0,552 ± 0,015 I ≤ 1,3 I ≤ 1,9Internal Exposure Index (I_Ra): I = 0,345 ± 0,009 I ≤ 1,0 I ≤ 1,3Radioactivity Index - Radiation Protection 112 of European Commission (ISBN 92-828-8376-0)

Measured value Reference values

I = 0,720 ± 0,019 I ≤ 0,5 Exemption I ≤ 1,0 Control

Notes: NoneThe technical operator The technical supervisor

Dr. Dino Giuliano Ferioli Ing. Massimo EspositoQualified Expert - N. 572

U-Series Srl - Via Ferrarese 131 - 40128 Bologna Tel. 051 0875113/114 - Fax. 051 4158173

Quality Management System Company certified by CERMET according to UNI EN ISO 9001:2008

UNI 10797:1999 - “Radionuclidi naturali nei materiali da costruzione – Determinazione mediante spettrometria gamma ad alta risoluzione”

214Pb214Pb214Bi214Bi214Bi226Ra228Ac228Ac228Ac228Ra232Th212Pb208Tl228Th137Cs

40K

E-mail [email protected] - http://www.u-series.com

Bologna, 27 Settembre 2010

Spett.

Dom Ceramiche

Strada Statale 569, 167/A

41050 Solignano

OGGETTO: Misurazione della concentrazione di radioattività.

Rapporto di prova n. 3622.

Con riferimento agli accordi intercorsi vogliate gentilmente trovare in allegato alla

presente il rapporto di prova relativo alla misura di radioattività effettuata nei modi e nei

termini previsti.

Conformemente alle indicazioni contenute nella "Radiation Protection 112", preparato dalla

Commissione Europea, e nella Norma GB 6566 della Repubblica Popolare Cinese, gli indici per

valutare i requisiti di sicurezza dei materiali che entrano a far parte in modo definitivo di

un'abitazione sono rispettivamente:

I = ATh/200+ARa/300+AK/3000

per la Norma redatta dalla Commissione Europea;

Iγ (Indice di esposizione esterna) = ATh/260+ARa/370+AK/4200

IRa (Indice di esposizione interna) = ARa/200

per la Norma GB 6566 della Repubblica Popolare Cinese, dove ATh, ARa, AK, sono le attività,

espresse in Bq/kg, rispettivamente del 232Th, 226Ra e del 40K.

_______________________________________________

U-Series Srl - Via Ferrarese 131 - 40128 BolognaTel. 051 0875113/4 - Fax. 051 0875110

E-mail [email protected] - http://www.u-series.com

Per la certificazione europea i prodotti sottoposti a misura devono soddisfare i seguenti

requisiti:

- Valore di esenzione I ≤ 0,5: questo valore suggerisce, in determinate circostanze,

una dose in eccesso di 0,3 mSv/anno; i materiali che rispettano questo indice possono

essere considerati esenti da qualsiasi restrizione, riguardo per esempio alla quantità

usata e alla destinazione d'uso dell'edificio.

- Valore di controllo I ≤ 1: questo valore suggerisce, in determinate circostanze, una

dose in eccesso, rispetto al fondo naturale, di 1 mSv/anno, e valori superiori all'unità

devono essere tenuti in considerazione dal punto di vista della salvaguardia della

salute;

Per la certificazione cinese, invece, i prodotti sottoposti a misura devono soddisfare i

seguenti requisiti:

- per i prodotti di classe A gli indici di esposizione esterna ed interna devono essere

rispettivamente Iγ ≤ 1,3 e IRa ≤ 1,0 ;

- per i prodotti di classe B gli indici di esposizione esterna ed interna devono essere

rispettivamente Iγ ≤ 1,9 e IRa ≤ 1,3

Sulla base della misura effettuata e con riferimento al rapporto di prova allegato, per

l'analisi da voi commissionata abbiamo ottenuto i seguenti risultati:

_______________________________________________

U-Series Srl - Via Ferrarese 131 - 40128 BolognaTel. 051 0875113/4 - Fax. 051 0875110

E-mail [email protected] - http://www.u-series.com

Campione Rapporto N. IRP112IGB6566

Iγ IRa

Piastrella Ceramica Dwas

520 Morning Gold3622 0,720 ± 0,019 0,552 ± 0,015 0,345 ± 0,009

dove l'incertezza è calcolata a due deviazioni standard. Per maggiore informazione, nel

certificato è riportata anche la concentrazione misurata 137Cs.

Ing. Massimo Esposito

Esperto Qualificato – N. 572 d’iscrizione

_______________________________________________

U-Series Srl - Via Ferrarese 131 - 40128 BolognaTel. 051 0875113/4 - Fax. 051 0875110

E-mail [email protected] - http://www.u-series.com

MISURAZIONE DELLA CONCENTRAZIONE DI RADIOATTIVITA'RAPPORTO DI PROVA N. 3622

Data di rilascio: 27 settembre 2010Committente:Dom CeramicheStrada Statale 569, 167/A 41050 SolignanoDescrizione campione:Piastrella Ceramica Dwas 520 Morning GoldProduttore:Dom CeramicheStrada Statale 569, 167/A 41050 SolignanoPrelievo del campione:Prelievo: Data indefinita Modalità di prelievo: A cura del committenteConsegna: 27 luglio 2010 Modalità di consegna: SpedizioneNorme di riferimento:

Risultati:Data misura: 10 settembre 2010 Codice misura: V3622

RadionuclideEnergia Concentratione Errore statistico Limite di rivelabilità (keV) (Bq/kg) (Bq/kg) (Bq/kg)295,22 72 4 5351,99 68 3 3609,32 69 4 41120,28 70 8 91764,51 70 8 9

--- 69,0 1,9 3,0338,40 64 7 9911,07 54 5 5968,90 58 6 7

--- 58 3 5--- 58 3 5

238,63 61 2 2583,1 58 4 4

--- 60 2 2661,62 <1,5 0 1,51460,75 610 30 20

Indici di radioattività (Norma GB6566-2001 della Repubblica Popolare Cinese)

Valore misurato Valori di riferimentoClasse A Classe B

Indice di esposizione esterna (Iγ): I = 0,552 ± 0,015 I ≤ 1,3 I ≤ 1,9Indice di esposizione interna (I_Ra): I = 0,345 ± 0,009 I ≤ 1,0 I ≤ 1,3Indice di radioattività - Radiation Protection 112 della Commissione Europea (ISBN 92-828-8376-0)

Valore misurato Valori di riferimento

I = 0,720 ± 0,019 I ≤ 0,5 Esenzione I ≤ 1,0 Controllo

Note: NessunaIl Tecnico di Laboratorio Il Responsabile di LaboratorioDr. Dino Giuliano Ferioli Ing. Massimo Esposito

Esperto Qualificato di III Grado - N. 572 d'iscrizione

U-Series Srl - Via Ferrarese 131 - 40128 Bologna Tel. 051 0875113/114 - Fax. 051 4158173

Azienda con Sistema di Gestione della Qualità Certificato da CERMET secondo UNI EN ISO 9001:2008

UNI 10797:1999 - “Radionuclidi naturali nei materiali da costruzione – Determinazione mediante spettrometria gamma ad alta risoluzione”

214Pb214Pb214Bi214Bi214Bi226Ra228Ac228Ac228Ac228Ra232Th212Pb208Tl228Th137Cs

40K

E-mail [email protected] - http://www.u-series.com