4
Gendrive Series 2000 Gx5 for Power Generation Continuous/Peak Applications with water-to-air charge air cooling Power. Passion. Partnership. Dimensions and Masses Engine Dimensions (LxWxH) mm (in) Mass, dry kg (lbs) 12V 1835 x 1580 x 1570 (72 x 62 x 62) 2570 (5665) 16V 2180 x 1580 x 1580 (86 x 62 x 62) 3180 (7010) 18V 2350 x 1580 x 1600 (93 x 62 x 63) 3580 (7893) All dimensions are approximate, for complete information refer to the installation drawing. Engine Model Bore/stroke mm (in) 130/150 (5.1/5.9) Cylinder configuration 90°V Displacement/cylinder l (cu in) 1.99 (121) Displacement, total l (cu in) 12V: 23.9 (1458), 16V: 31.8 (1944), 18V: 35.8 (2185) Fuel specification EN 590, Grade No.1-D/2-D (ASTM D975-00) Application group Power definition Continuous Power (3A) Heavy duty service, unrestricted Load factor: ≤ 100%, Operating hours: unrestricted, Overload: 10% capability (ICXN) Prime Power (3B) Continuous service, variable load, Load factor: ≤ 75%, Operating hours: unrestricted, ICXN Overload: 10% capability (ICXN) Power definition according to ISO 3046 (ratings also correspond to SAE J 1995 and SAE J 1349 standard conditions). Consult your MTU distributor/dealer for the rating that will apply to your specific application. Rated power is without fan drive. The power consumption of any fan drive has to be deducted during designing of a generator set.

Gendrive Series 2000 Gx5 - arbas.co.idarbas.co.id/wp-content/uploads/2016/12/32310291... · Gendrive Series 2000 Gx5 for Power Generation Continuous/Peak Applications with water-to-air

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Gendrive Series 2000 Gx5 - arbas.co.idarbas.co.id/wp-content/uploads/2016/12/32310291... · Gendrive Series 2000 Gx5 for Power Generation Continuous/Peak Applications with water-to-air

Gendrive

Series 2000 Gx5 for Power Generation Continuous/Peak Applicationswith water-to-air charge air cooling

Power. Passion. Partnership.

Dimensions and Masses

Engine Dimensions(LxWxH)mm(in) Mass,drykg(lbs)

12V 1835x1580x1570(72x62x62) 2570(5665)

16V 2180x1580x1580(86x62x62) 3180(7010)

18V 2350x1580x1600(93x62x63) 3580(7893)

Alldimensionsareapproximate,forcompleteinformationrefertotheinstallationdrawing.

EngineModel

Bore/stroke mm(in) 130/150(5.1/5.9)

Cylinderconfiguration 90°V

Displacement/cylinder l(cuin) 1.99(121)

Displacement,total l(cuin) 12V:23.9(1458),16V:31.8(1944),18V:35.8(2185)

Fuelspecification EN590,GradeNo.1-D/2-D(ASTMD975-00)

Applicationgroup Powerdefinition

ContinuousPower(3A) Heavydutyservice,unrestricted Loadfactor:≤100%,Operatinghours:unrestricted,

Overload:10%capability(ICXN)

PrimePower(3B) Continuousservice,variableload, Loadfactor:≤75%,Operatinghours:unrestricted,

ICXN Overload:10%capability(ICXN)

PowerdefinitionaccordingtoISO3046(ratingsalsocorrespondtoSAEJ1995andSAEJ1349standardconditions).ConsultyourMTUdistributor/dealerfortheratingthatwillapplytoyourspecificapplication.Rated power is without fan drive. The power consumption of any fan drive has to be deducted during designing of a generator set.

Page 2: Gendrive Series 2000 Gx5 - arbas.co.idarbas.co.id/wp-content/uploads/2016/12/32310291... · Gendrive Series 2000 Gx5 for Power Generation Continuous/Peak Applications with water-to-air

2IContinuous/PeakApplications

referencetoemissionlevelinpricelist

Continuous Power (3A)

Engine Type Rated power kW (bhp) at 1500 rpm (50Hz) Optimization

12V2000G65 515(691) x

16V2000G65 655(878) x

18V2000G65 720(966) x

Fanpowerrequirementnotconsidered

Fuel

con

sum

ptio

n op

timiz

ed

Page 3: Gendrive Series 2000 Gx5 - arbas.co.idarbas.co.id/wp-content/uploads/2016/12/32310291... · Gendrive Series 2000 Gx5 for Power Generation Continuous/Peak Applications with water-to-air

3IContinuous/PeakApplications

193 referencetoemissionlevelinpricelist

Prime Power (3B)

Engine Type Rated power kW (bhp) at 1500 rpm (50Hz) Optimization

12V2000G25 580(778) x

12V2000G65 695(932) x

16V2000G25 810(1086) x

16V2000G65 890(1194) x

18V2000G65 1000(1341) x

FanpowerrequirementnotconsideredFu

el c

onsu

mpt

ion

optim

ized

Engine Type Rated power kW (bhp) at 1800 rpm (60Hz) Optimization

12V2000G45 710(952) x x

12V2000G85 810(1086) x x

16V2000G45 915(1227) x x

16V2000G85 1010(1354) x x

18V2000G85 1191(1597) x x

Fanpowerrequirementnotconsidered

US

EPA

Non

road

Tie

r 2

com

plia

nt (4

0 C

FR 8

9)

19

US

EPA

Sta

tiona

ry

EMER

G T

ier

2 (4

0 C

FR 6

0)

3

Page 4: Gendrive Series 2000 Gx5 - arbas.co.idarbas.co.id/wp-content/uploads/2016/12/32310291... · Gendrive Series 2000 Gx5 for Power Generation Continuous/Peak Applications with water-to-air

MTU Friedrichshafen GmbH I MTU Asia Pte Ltd I MTU America Inc.Rolls-RoycePowerSystemsCompanies

www.mtu-online.com

Subj

ectt

och

ange

.|3

2310

291

|Ed

ition

01/

16|

EN

C2

016-

03.

StandardEquipment

StartingSystem Electricstarter(24VDC/2-pole)

FuelSystem Electronicallycontrolledhigh-pressureinjectionwithsingleunitinjectionpumps(EUP)

LubeOilSystem Forcedfeedlubricationsystemwithpistoncooling,lubeoilcirculationpumpwithsafetyvalve,lubeoilmulti-stage

filter,lubeoilheatexchanger

CombustionAirSystem Exhaustturbochargers,intercooler

CoolingSystem Coolantcirculationpumpandcoolantthermostatforjacketwaterandchargeaircoolingsystem

EngineMounting Setofenginemountingbracketsatenginefreeanddrivingend

EngineManagement IntegratedelectronicenginecontrolandmonitoringsystemADEC

OptionalEquipment

StartingSystem Redundantstartingsystemelectric/air;electric/electric;air/air

FuelSystem Fuelpre-filter,specialfuelpre-filterwithwaterseparator

LubeOilSystem Handpumpforlubeoilextraction,electricalintervalpre-lubricationpump

CombustionAirSystem Heavydutyairfilters

EngineMounting Resilientenginemounts(rubberelements),rigidenginemounting

Referenceconditions:–Intake-airtemperature:25°C(77°F)–Ambientairpressure:1bar(14.5psi)–Altitudeabovesealevel:100m(328ft)

Subjecttochangewithoutnotice.Customizationpossible.Enginesillustratedinthisdocumentmayfeatureoptionsnotfittedasstandard.