Upload
majortay
View
218
Download
0
Embed Size (px)
Citation preview
7/28/2019 FW e3co Star Sales Brochure
1/5
e3
CO - Star
Energy Recovery Unit > Sales Brochure
CFD Optimised Design for Maximum SavingsCompact Side-by-Side ormat or easy installation
Plate heat Exchanger eiciency up to 70%Airlow up to 1.0 m3/s (3600 m3/h)
Very Low Breakout Noise LevelsEnhanced indoor comort
High Efficiency EC Motor TechnologySFP values as low as 0.17 w/ l/s
Part L SFP compliant across the range
User Friendly Controls with Touch Screen HMIFully programmable or maximum lexibility
Full BMS communication (via Modbus) as standard
Integrated Exchanger
7/28/2019 FW e3co Star Sales Brochure
2/5
EDUCATION
High occupancy levels
during teaching periodsrequire energy-efficient andcontrollable demand-based
management of air quality andtemperature. The comfort,
health and alertness ofstaff and pupils is ensuredduring the learning process,
but operating costs can beminimised when these facilitiesare unoccupied.
GYMNASIUM/INDOOR SPORTS
Differing types of activityand occupancy mean a
broad spectrum of functionalrequirements to ensure efficientremoval of used air and the
introduction of fresh supplies.Systems need to contain and
control the periodic build upof high humidity levels andtemperature.
HEALTHCARE
For a hospital to operate atits maximum potential, it has tohave all systems working
at the optimum. This notonly applies to staff,
communications and lifesupport systems, but alsoto pipework, cleaning and
ventilation systems.
OFFICES
Flkt Woods offer a highperformance product rangecovering all key elements of
the overall ventilation system.Our products are designedto secure the best overall
performance of the system as awhole, considering parameters
such as health and air quality,energy efficiency, noise, firesafety and ease of installation.
RETAIL/SHOPPING AREAS
With high activity levels
during the working week andweekends, its important tomake sure that all areas of
ventilation are maintained andFlkt Woods has the systems
to achieve all requirements.
APARTMENTS
The purpose of ventilation is to
provide clean good quality airby removing the stale, polluted
air from our homes. The maintask is of course to ensure thatthe indoor air is healthy and
safe to breathe. Ventilationtoday is also about energy and
saving energy costs by addingheat recovery to the ventilationsystem.
INDUSTRY
Flkt Woods technologyis used widely in industrialprocessing plants and factories
for ventilation of work spaces,as vital components in high
tech manufacturing facilities,and for maintaining delicateenvironments within high
tolerance levels inpetrochemical and
pharmaceutical plants.
Applications
7/28/2019 FW e3co Star Sales Brochure
3/5
Controls User riendly interace - colour touch screen
Fast and easy commissioning - saving time on site
Pre-conigured controls - see Modular Control Solutions
Full BMS capability as standard via MODBUS protocol making controlintegration easy
Scheduler unction included
Alarm Menu - easy alarm handling
USB port on microprocessor board - easy to update
Supply & Exhaust Fans - EC Motors fitted Complete with direct driven centriugal ans; single or double inlet with
orward curved impeller blades
Direct driven via high-perormance EC (Electronically Commutated) motors
with built in speed control and the rmal protection as standard.
EC technology is an ecological solution guaranteeing low energy
consumption and better management and control o the
operating point (air lows can be controlled rom 30 to 100%)
Pa
HS air flow
LS air flow
Air flow
HS constant air flow
LS constant air flow
Air flow
Pa
CAVConstant Air Volume2 Constant Air low Options
VAVVariable Air Volume - Trickle & Boost Strategy2 Air low rates - Low Speed/High Speed
COPConstant Pressure Control
Pa HS air flow
LS air flow
Air flow
VAV AQVariable Air Volume plus CO
2sensor
Proportional air low control via CO2sensor
Pa
Constant pressure
Air flow
The e3co Star unit has a factory-pre-set controller as standard, which can be
used to configure how air flows can be modulated:
Modular Control Solutions
Features & Benefits
New optimised design layout Developed using CFD sotware
Reduced height allows or easy installation into ceiling voids;
Side access or inspection and maintenance;
Dierential pressure switches included as standard- provides dirty ilter alarm
Condensation drainage system, with side mounted drainpoint to minimise height
Very Low Breakout Noise Levels 30 dBA
Steel panels thickness is 0.9mm/0.7mm (inner/outer skins)
Internal rockwool insulation thickness is 25mm. Density is 60Kg/m3 -
giving a low noise solution, whilst optimising product weight.
Developed to meet UK BB93 & BB101 standards
PowerSaving
55%*
Product Range & Control Funtions
Heat Recovery Night/Free Temperature Anti Frost Post Heater Pre HeaterCooling Control
e3ssential
e3nhancede3lite
3 VARIANTS
6 models covering flow rates from 0.08 to 1.00 m3/s (300 to 3600m3/h)
Cross Flow Exchanger up to 70%
Cross-low heat exchanger core with aluminium plates is EUROVENT certiied
Design features a motorised by-pass damper. Control is
proportional from 0 to 100%
Automatic derost unction is included to protect the heat exchanger
Optimised design Maximizes use o exchanger core
Filters
Filters are included to provide protection to other components
(ie, exchanger/ans) and are designed or easy itting/removal
The e3co Star unit is equipped with G4 grade ilter media
itted to the resh air intake and return air intake.
F7 & F9 grade ilter media available on request
*55% power saving when using EC motors instead of AC motors, when alternative solutions compared in a case study
Airflow area
covered =
95%
7/28/2019 FW e3co Star Sales Brochure
4/5
** Operating at a thermal efficiency of 57% (based on UK case study)
W K
H
C
S
F
10
L
Energy Recovery Comparison
Drawing & Dimensions
Performance Information
71%Reduction15000
10000
5000
0
No Heat Recovery **Heat Recovery Unit
10,267
3,011
Energy Consumption(kWh)
400
0
50
100
150
200
250
300
350
0 0.2 0.4 0.6 0.8 1 1.2
Volume Flow (m /s)3
Size 1 Size 2 Size 3 Size 4 Size 5 Size 6
Size 1 Size 2 Size 3 Size 4 Size 5 Size 6
Fan Data
Max Installed Power: Watts input 175 x2 171 x2 465 x2 450 x2 750 x2 1000 x2
Nominal Running speed: rpm 2150 1740 1640 1085 1030 880
Fan Motor FLC: amps 1.3 x 2 1.3 x 2 3.0 x 2 2.8 x 2 3.4 x 2 1.7 x 2
Fan Motor IP rating 44 44 54 54 54 54
Motor Insulation class B B B B B B
Unit Data
Max Running temperature: C -10/+40C -10/+40C -10/+40C -10/+40C -10/+40C -10/+40C
E lectr ic al Supp ly : V/Ph/Hz 230/1/50 230/1/50 230/1/50 230/1/50 230/1/50 415/3/50
Thermal Recovery Performance
Recovered Thermal Power: kW 2.5 3.6 6.1 7.1 11.0 16.0
Air o temperature: C 9.9 10.0 8.2 8.3 9.3 9.4
Condensate rate: l/h 0.5 0.8 0.9 1.1 2.1 3.1
SFP (values stated as per fan)
Boost 0.88 0.88 0.70 0.72 0.68 0.75
75% Speed 0.75 0.58 0.62 0.50 0.50 0.52
Trickle 0.27 0.17 0.20 0.18 0.18 0.18
Breakout dB(A) @ 3m
Boost 29 31 30 25 29 33
75% Speed 27 25 28 21 25 28
Trickle
7/28/2019 FW e3co Star Sales Brochure
5/5
FlktWoodsoperatesapolicyofcontinuousimprovementandreservestherighttosupplyproductsthatmaydifferfrom
thoseillustratedanddescribedinthispublication.Certifieddimensionscanbesuppliedonrequestonreceiptoforder.
Flkt Woods Group - Ventilation Solutions
Flkt Woods LimitedAxial Way, ColchesterEssex, C04 5ZDUNITED KINGDOMTel: +44 (0)1206 222 555
Fax: +44 (0)1206 222 777E-mail: [email protected]
Flkt Woods OyKalevantie 39FI-20520TurkuFINLANDTel: +358 20 442 3000Fax: +358 20 442 3018E-mail: [email protected]
Flkt Woods OyHmeentie 23FI-37800ToijalaFINLANDTel: +358 20 442 3500Fax: +358 20 442 3502E-mail: [email protected]
Flkt Woods ABGesllgatan 17745 39EnkpingSWEDENTel: +46 36 19 30 00Fax: +46 17 12 40 97E-mail: [email protected]
Flkt Woods ABKung Hans vg12 192 68, SollentunaSwedenTel: +46 (0)771 26 26 26
Fax: +46 (0)8 626 73 10E-mail: [email protected]
Flkt Woods ABFlktvgen 2, Box 84153 22JrnaSWEDENTel: +46 8-551795 00Fax: +46 8-551744 80E-mail: [email protected]
Flkt Woods4 Avenue LaurentCELY-Batiment C - Etage 3Asnieres Sur Seine92600 FRANCETel: +33 1 80 21 07 00Fax: +33 1 80 21 07 00E-mail: [email protected]
Flkt Woods Ventilatoren GmbHAm Sportplatz 4DE-40882RatingenGERMANYTel: +49 2012 61038 11Fax: +49 2102 61038 18E-mail: [email protected]
Flkt Woods SpAVia Pacinotti, 28IT-20092, Cinisello BalsamoITALYTel: +39 02 6186 6091
Fax: +39 02 6186 0947E-mail: [email protected]
Flkt Bovent Sp. z o.o.Panattoni Park Pruszkw IIul. Poudniowa 2, Otarzew05-850 Oarw MazowieckiPOLANDTel: +48 22 392 43 43Fax: +48 22 392 43 44E-mail: [email protected]
LLC Flkt Industrial& Building Systems23, ul. ProsojuznayaRU-117418 MoscowRUSSIATel: +7 (495) 589-31-08Fax: +7 (495) 589-31-74E-mail: [email protected]
The Flkt Woods Group is divided into three businesses:
Global Infrastructure and Industry (GII)A leader or Air Movement using ans to improve perormance o equipment and industrialprocesses
Air Climate Solutions (ACS)A worldwide HVAC leader recognized by our customers as a provider o superior Air ClimateSolutions combining Indoor Air Quality and Energy Efciency applied to specifed buildings
Ventilation Solutions (VS)A European Ventilation Specialist Servicing our customers with a complete range o
ventilation products ocused on Non residential buildings. For more specifc productinormation or Ventilation Solutions, please visit:
www.vsecatalogue.flaktwoods.com
VS/ESSB-EN
G-01/0612
Flkt Woods Limited
Axial Way, Colchester, Essex, C04 5ZD
Tel 01206 222 555 Fax 01206 222 777
email [email protected] www.laktwoods.co.uk