Furnace Start-up and Shutdown

Embed Size (px)

DESCRIPTION

Furnace Start-up and Shutdown

Citation preview

  • 5/25/2018 Furnace Start-up and Shutdown

    1/47

    A Sunrise Project for a Sunshine Future

    PARADEEP REFINERY PROJECT

    FacultyN R Das

    SPNE-CG

    Prepared byProduction-CG Team

  • 5/25/2018 Furnace Start-up and Shutdown

    2/47

    AGENDA FOR THE PRESENTATION

    PARADEEP REFINERY PROJECT

    Configuration of High Efficiency/ Modern Heaters

    Heater Instrumentation and controls

    Introduction to Burner Management System

    Heater Commissioning/ Start-up

    Start-up Precautions and Monitoring

    Heater Shutdown

    What May Go Wrong

    A Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    3/47

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    4/47

    CONFIGURATION OF MODERN HEATERS

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    5/47

    CONFIGURATION OF MODERN HEATERS

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    6/47

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    7/47

    HEATER INSTRUMENTATION & CONTROLS

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    PC

    TC

    FC

    PT

    PT

    FQ

    FT

    FT

    FC

    FC

    FC

    O2

    SOxNOx

    TT

    TT

    TT

    TT

    TT

    PTTT

    TT

    TTTT

    FT

  • 5/25/2018 Furnace Start-up and Shutdown

    8/47

    HEATER FIRING CONTROL

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    PC

    TC

    FC

    FT

    PT

    FQ

    FT

    FT

    FC

    FC

    FC

    O2

    SOxNOx

    TT

    TT

    TT

    TT

    TT

    PTTT

    TT

    TTTT

    FIRING

    CONTROL

  • 5/25/2018 Furnace Start-up and Shutdown

    9/47PARADEEP REFINERY PROJECT

    A Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    10/47

    NEED FOR BMS

    PARADEEP REFINERY PROJECT

    BMS System evolved out of a need for a Separate System apart

    from the control system for

    Optimization of fuel consumption

    Safe start-up of the furnace through programmed sequences bounded by

    safety Interlocks and Start permissives

    Supervising the safety limits during operation

    Supervising the presence of pilot and Main flame during operation with the

    help of Dedicated flame scanners

    Activation of safe Shutdown in the event of any unsafe condition

    Preventing the catastrophic combustion of fuel or Explosion

    For providing the operating personal an environment free of Hazards

    A Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    11/47

    BMS - How Burner is managed?

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    Sequence Controls (Permissives)-For Startup

    Pilot & Main Fuel Block Valves leak proved Absence of Flame proved

    Prepare flow proved

    Prepurge Timer complete

    Minimum configured pilots are lit

    Trip Interlocks-For Normal Operation

    Loss of Flame

    Fuel pressure Low

    Fuel pressure High Loss of Combustion air

    High Process Temperatures

  • 5/25/2018 Furnace Start-up and Shutdown

    12/47PARADEEP REFINERY PROJECT

    A Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    13/47

    SAFETY CHECKS BEFORE HEATER STARTUP

    PARADEEP REFINERY PROJECT

    A furnace is safest when it is functioning properly.

    Combustion occurs when fuel and oxygen meet a source of ignition.

    If any one of these three elements is missing, ____________ cannot take

    place.

    Combustion can occur in an idle furnace, if fuel, oxygen, and a source of

    ignition come together. Wherever there ia air, you can be sure there is

    _______________.

    During shutdown, flammable vapors may seep into the firebox. Anything

    that can burn is ______________.

    A Sunrise Project for a Sunshine Future

    combustion

    oxygen

    flammable

  • 5/25/2018 Furnace Start-up and Shutdown

    14/47

    SAFETY CHECKS BEFORE HEATER STARTUP

    PARADEEP REFINERY PROJECT

    Fuel and oxygen need only a source of ignition to ________.

    Even though a furnace is idle, you must assume that there may be ________

    in the firebox.

    Rapid ignition or combustion in a confined space is an explosion. Explosions

    occur when air and fuel have mixed and come into contact with a source of

    __________.

    The longer an unblinded furnace has been idle, the more likely it is to lack

    only a _________ of ignition.

    Over the years, more than half of all furnace explosions have occurred

    during startup. Most explosions happened because fuel that the operator

    didntknow was there had mixed with _______ and was waiting for ignition.

    A furnace is most dangerous at ______________.

    A Sunrise Project for a Sunshine Future

    Start up

    burn

    fuel

    ignition

    source

    air

  • 5/25/2018 Furnace Start-up and Shutdown

    15/47

    PHYSICAL CHECK BEFORE STARTUP

    PARADEEP REFINERY PROJECT

    The furnace and the area around it must be clean and free of flammable

    material.

    All valves in the fuel gas and fuel oil systems and all burner valves must be

    checked to see that they are closed.

    Both the _________ gas valve and the pilot valve must be checked to be

    sure they are _____________.

    A Sunrise Project for a Sunshine Future

    steam

    On an oil burner, you normally

    have two oil valves and three

    steam valves to close. All

    _______ and ________ valves

    must be closed.

    burner

    closed

    oil

  • 5/25/2018 Furnace Start-up and Shutdown

    16/47

    PHYSICAL CHECK BEFORE STARTUP

    PARADEEP REFINERY PROJECT

    After the damper mechanism has been checked, the stack ___________

    should be fully opened.

    The secondary air doors on all _____________ should be fully opened.

    To purge the furnace properly later on, the purging steam or air must be

    able to flow freely through the furnace. The stack damper and all secondary

    air dampers must be _________ to provide this flow.

    A Sunrise Project for a Sunshine Future

    damper

    burners

    open

  • 5/25/2018 Furnace Start-up and Shutdown

    17/47

    PURGING BEFORE LIGHTING THE BURNERS

    PARADEEP REFINERY PROJECT

    It is dangerous to light the burner without ________the furnace first.

    Purging must be thorough to make sure that no flammable __________remain in the furnace.

    Steam is used for purging. Ensure that the steam is free of condensate.

    Steam purging provides heat to start the draft.

    Your unit operating instructions tell you how long to purge the furnace with

    steam, and may specify a minimum draft during the purge.

    Purging is used to create a _________ and remove all flammable

    __________ from the furnace.

    A Sunrise Project for a Sunshine Future

    gases

    purging

    gases

    draft

  • 5/25/2018 Furnace Start-up and Shutdown

    18/47

    PURGING BEFORE LIGHTING THE BURNERS

    PARADEEP REFINERY PROJECT

    Purging makes sure that you have the three elements of ____________

    (fuel, air, and heat) under control when you light the burners.

    Ensure that there are no flammable vapors mixed with air in the firebox.

    A Sunrise Project for a Sunshine Future

    combustion

  • 5/25/2018 Furnace Start-up and Shutdown

    19/47

    REMOVING BLINDS - BEFORE LIGHTING THE BURNERS

    PARADEEP REFINERY PROJECT

    Before lighting the burners, follow Standing Instructions and SOP (Standard

    operating procedures).

    Ensure that the blinds in the main fuel lines to the furnace are removed as

    per unit operating instructions. Purge the fuel system as per the instructions.

    With the blinds removed, the chances that the fuel may seep into he firebox

    through any valve leakage are now increased.

    Ensure that all burner valves are __________ before opening the main fuel

    valve to furnace.

    Drain fuel gas knockout pot to ensure that there is no presence of liquid

    hydrocarbon in fuel gas.

    Ensure that there is no water in the fuel oil line.

    A Sunrise Project for a Sunshine Future

    closed

  • 5/25/2018 Furnace Start-up and Shutdown

    20/47

    LIGHTING THE BURNERS

    PARADEEP REFINERY PROJECT

    On a furnace with a gas pilot, light the pilot before you light the burner.

    Once the pilot is lighted, it is a steady __________ of ignition for the burner.

    Establish circulation through furnace coils before the first __________ is

    lighted.

    A furnace burning both gas and oil is normally started with ________.

    The gas burner provides a steady source of __________ for the oil.

    Gas ignites and burns more easily than oil.

    Begin lighting the burners immediately after you have finished __________

    purging the furnace.

    Automatic igniters are installed for lighting of pilot burners.

    A Sunrise Project for a Sunshine Future

    source

    burner

    gas

    ignition

    purging

  • 5/25/2018 Furnace Start-up and Shutdown

    21/47

    LIGHTING THE BURNERS

    PARADEEP REFINERY PROJECT

    Portable igniters are also used to light the pilot burners.

    In earlier days, torch was used to light the pilot burners.

    After lighting the burner, steady the ________ pattern by adjusting air

    dampers.

    If the fuel does not ignite promptly, shut off the burner.

    If the fuel does not ignite at the first burner, you must _______________.

    If you have to purge again, repeat the whole ___________ procedure.

    One burner should never be lighted from another burner. This is a

    dangerous practice. Only a _________ provides a steady and reliable source

    of ignition.

    A Sunrise Project for a Sunshine Future

    flame

    purge again

    purging

    pilot

  • 5/25/2018 Furnace Start-up and Shutdown

    22/47

    LIGHTING THE BURNERS

    PARADEEP REFINERY PROJECT

    When you are firing two fuels, one is normally base loaded and you

    control temperature with the other.

    Do not try to light the oil gun of a combustion burner until the _______

    burners are maintaining a stable flame pattern.

    Ensure draining of _____________ from atomising steam line, before

    lighting up oil burner.

    During startup, frequently check the individual burner flames and the

    flame pattern in the ____________. Wear a face mask whenever you look

    into the firebox.

    Watch for irregular burning patterns. Flame impingement causes hot spots.

    Watch the radiant tubes for hot spots and adjust the _________ pattern to

    eliminate them.

    A Sunrise Project for a Sunshine Future

    firebox

    gas

    condensate

    flame

  • 5/25/2018 Furnace Start-up and Shutdown

    23/47

    LIGHTING THE BURNERS

    PARADEEP REFINERY PROJECT

    Tubes should be checked from shift to shift to detect hot ________ and to

    observe how much the spots are changing, and how fast.

    After the furnace is on stream and lined out, check the entire operation for

    draft and _________ air control.

    A Sunrise Project for a Sunshine Future

    excess

    spots

  • 5/25/2018 Furnace Start-up and Shutdown

    24/47

    HEATER STARTUP PRECHECKS

    PARADEEP REFINERY PROJECT

    Check all the following conditions are satisfied

    Check if all the Manual block valves in fuel lines are closed

    Fuel gas control valve set at 20% on manual mode

    Steam to SAPH closed

    All burner air dampers are open

    Stack Damper Open

    ID fan inlet (IGV) closed

    Flue gas analyser not in operation

    A Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    25/47

    START PERMISSIVES

    PARADEEP REFINERY PROJECT

    Check if all the following Permissives are Healthy

    All pilot flame scanners unhealthy.

    All main flame scanners unhealthy.

    All pilot header block valves closed and bleed valves open.

    All main FG header block valves closed and bleed valves open.

    All BMS interlocks are healthy/necessary interlocks bypassed.

    Local Reset Push button activated.

    Main stack damper open.

    A Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    26/47

    FUEL GAS LINESPURGING & LEAK CHECK

    PARADEEP REFINERY PROJECT

    Purging of Pilot and Fuel Gas lines

    Before admitting fuel gas into the line to the burners it may be

    necessary when fuel gas is containing more than 15 vol. % H2 to purgethe line with nitrogen.

    Connect N2 Hose in the common fuel gas line LPD downstream of Filter

    pressurize and purge it through HPV in the ring headers of Pilot and Main FG

    Leak Check of Pilot Gas line Automatic Block Valves

    Line-up all the block valves in Pilot and Main FG lines (except burner

    globe and ball valves)

    Initiate Pilot & Main burner leak check by pressing Start leak test

    Push Button Pilot leak test in progress lamp glows in LCP and a preset timer starts

    which will be reset only if Start purge button Pressurisation step: Pilot gas line bypass block valves open and bleed valve

    closes. The system checks if the downstream pressure reaches the upper

    leak check set point within the pressurisation period (1 min and

    adjustable).

    A Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    27/47

    FUEL GAS LINESPURGING & LEAK CHECK

    PARADEEP REFINERY PROJECT

    Depressurisation Step: Pilot gas line bypass block valves closes and bleed

    valves open. The system checks if the downstream pressure reaches the

    lower leak check set point within the depressurisation period (1 min andadjustable)

    If Pressurisation and depressurisation steps are completed successfully

    Pilot Leak test clear appears in LCP. If during pressurisation or

    depressurisation tests, the set value checks fail Pilot leak test failed

    appears in LCP.

    If leak check fails rectify the problem and start leak test again.

    A Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    28/47

    FUEL GAS LINESPURGING & LEAK CHECK

    PARADEEP REFINERY PROJECT

    Leak Check of Main Fuel Gas line Automatic Block Valves

    Once the Pilot leak check is cleared, the BMS will automatically initiate

    Main FG leak check. Burner leak test in progress lamp glows in LCP.

    Pressurisation step: Main FG gas line bypass block valves open and bleed

    valve closes. The system checks if the downstream pressure reaches the

    upper leak check set point within the pressurisation period (1 min and

    adjustable)

    Depressurisation Step: Main Fuel gas line bypass block valves closes andbleed valves open. The system checks if the downstream pressure reaches

    the lower leak check set point within the depressurisation period (1 min

    and adjustable)

    If Pressurisation and depressurisation steps are completed successfully

    Burner Leak test clear appears in LCP. If during pressurisation or

    depressurisation tests, the set value checks fail Burner leak test failedappears in LCP.

    If leak check fails rectify the problem and start leak test again.

    A Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    29/47

    FUEL GAS LINESLEAK CHECK

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    PT

    PT

    O2

    SOxNOx

    TT

    TT

    TT

    TT

    TT

    FT

  • 5/25/2018 Furnace Start-up and Shutdown

    30/47

    FURNACE BOX PRE-PURGING

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    Heaters must be purged with air before burners are lighted to evacuate all gas

    that could have been sent to the firebox during the test

    Now start FD fans (at least one) as per the start-up procedure and open

    the discharge damper

    Reach a maximum air flow or flow recommended by vendor.

    Activate Start Purge Push button.

    All the above steps are to be completed before timer that got activated

    during burner leak check (Depends upon the vendor)

    Minimum Purgiging time should be such that it should renew 5 times the

    volume of heater or 15 Minutes

  • 5/25/2018 Furnace Start-up and Shutdown

    31/47

    PILOT GAS BURNERS LIGHT-UP

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    Pilot gas burner light-up Preparation

    Reduce the air flow from FD fan to say 25% of capacity

    Adjust the stack damper so that the proper draft level for furnace operation isachieved.

    Close the burner air control dampers to the 25% open position.

    Pilot gas burner light-up can be started once the Open pilot block valves

    push button is pressed Open the main pilot fuel supply valve making fuel gas available upto all of the

    individual pilot valves

    Keep the pilot mixer air door is of the pilot to be first lit-up to say 50% open.

    Insert the igniter, Press the Open push button for that pilot to be lit-up and

    activate the igniter. The pilot should light instantly. If the pilot does not light after 10 seconds

    automatic block valve will get closed.

    If lit-up adjust the pilot valve and air door for a stable flame.

    Light up all pilots in the same manner.

  • 5/25/2018 Furnace Start-up and Shutdown

    32/47

    MAIN GAS BURNERS LIGHT-UP

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    Main gas burner light-up Preparation

    Adjust the draft such that there is sufficient air pressure drop across the burner

    Set the burner air control dampers at 50% open.

    Main gas burner light-up can be started once the Open main FG block

    valvespush button is pressed

    Now the automatic block valves will open and charge the FG upto individual block

    valves

    The burners can now be ignited manually by opening the burner isolation valve

    (ball valve) slowly while observing the flame.

    If flame is not established within 3 secs of valve being fully open, it should be

    closed immediately. Further attempts shouldnt be made for 5 minutes.

    All main burners can be lit up in similar fashion.

    Adjust the operating conditions as required by the process. But the minimum

    firing rate prescribed by the vendor should be respected.

    Adjust the conditions for optimum O2 level in the Stack

  • 5/25/2018 Furnace Start-up and Shutdown

    33/47

    OIL BURNERS LIGHT-UP

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    Oil burner light-up Preparation

    Reset the Oil supply and return automatic block valves

    Lineup supply and return line valves upto the individual burner block valves

    Establish oil circulation

    Light-up Sequence

    The burner which is going to be taken in line should already be lit-up with fuel gas Open the steam valve and cross over valve (purge) to the oil gun until both oil and

    steam lines to each burner and also the oil gun are completely warmed up with

    steam only.

    Close cross over valve and adjust steam valve to 3.5-4.0 Kg/cm2g steam pressure.

    Open oil valve gradually until ignition is established. Isolate fuel gas to that Burner

    Adjust oil valve for capacity required and adjust steam valve to achieve proper

    flame pattern.

  • 5/25/2018 Furnace Start-up and Shutdown

    34/47

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    35/47

    START-UP PRECAUTIONS

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    The following Precautions needs to be exercised during furnace start-up

    Quick heating-up is likely to cause excessive stresses on tubes and supports

    Over pressure in the fire chamber can cause personnel injury or material damage

    as hot flue gas would leak out of sight doors, not blanked-off connections,

    unpacked tube seals, etc

    Ensure Flow through the coils as it is a certain way of protecting the tubes from

    excessive temperature.

    Too low a flow rate through the passes with respect to heat flux can be the causeof tube overheating or hydrocarbon coking.

    Possibility of condensation in the fuel lines must be checked with respect to

    atmospheric conditions and avoided. Line must be drained frequently checking for

    water or condensates.

    Burner operation shall also be carefully and constantly watched to identify any

    abnormal occurrence: flame impingement, wrong shape, instability, nozzle

    plugging, coke formation, etc

    During start-up, heater draught must be watched as it increases progressively with

    the heat released

  • 5/25/2018 Furnace Start-up and Shutdown

    36/47

    START-UP MONITORING

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    During start-up, heater draught must be watched as it increases progressively

    with the heat released, using for that the draught gauges installed locally and

    comparing them to the values transmitted to control room. Operation of thedraught dampers when there is one must be smooth and draught must be

    effectively controlled.

    During first start-up, all devices and instruments being used for the first time

    in real conditions, it is of paramount importance to check their actualoperation and response constantly, until sufficient confidence is gained. Quick

    material and thermal balances will help to detect abnormal recordings.

    It comes naturally up that first start-up must be conducted slowly and if

    possible stepwise to allow timely checking and observation.

    In case of abnormal occurrence, it is of paramount importance that operators

    can react in the right way within the shortest time.

  • 5/25/2018 Furnace Start-up and Shutdown

    37/47

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    38/47

    CONTROLLED SHUTDOWN

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    Controlled Shutdown Sequence

    Reduce fuel pressure slowly from control panel and simultaneously reduce the

    combustion air flow

    Once fuel pressure downstream of Pressure control valve reduces to a minimum

    value or PCV opening reduced to minimum, start cutting off burners one by one.

    Individual burner air dampers needs to be throttled as CA duct pressure reduces.

    If oil burners are in line, isolate them and flush with atomizing steam

    When main fuel gas is to be tripped, close the PCV completely and automatically

    the block valves will get closed

    Open Stack damper fully.

    Actuate Pilot gas trip by isolating the main pilot line isolation valve. This action will

    trip FD fan also.

    Bypass Pilot gas low low pressure trip and Restart FD fan

    Allow cooling of the furnace box with FD fan running

  • 5/25/2018 Furnace Start-up and Shutdown

    39/47

    SHUTDOWN

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    The flow rate of the charge and the heat of the furnace are reduced together.

    The charge rate and temperature are gradually ____________ over a period

    of several hours.

    When the charge rate and temperature have been reduced to a fraction of

    normal, all furnace __________ are shut off.

    The entire unit is circulated down. The oil left in the unit is circulated within

    the unit oil system, including the ____________ tubes.

    Circulation is continued through most equipment for several hours to cool the

    unit. When the unit is cool enough not to vaporise the oil anywhere in it,

    circulation is __________.stopped

    reduced

    burners

    furnace

  • 5/25/2018 Furnace Start-up and Shutdown

    40/47

    SHUTDOWN

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    Reduction in the transfer temperature automatically ____________ the burner fuel

    supply. While reducing transfer temperature, cut off burners as per requirement.

    When the charge rate and temperature are down to the desired level, all

    ____________ are shut off by closing each burner fuel valve individually.

    Each gas pilot is shut off by closing the pilot _______.

    Steam is left on in each oil gun as the oil regulating valve is closed. It is used to

    _____________ the oil gun.

    After all the burner gas valves are closed, the gas header valve is closed. Then all block

    valves and bypass valves are closed.

    If the furnace is to be out of service for some time, blinds should be installed in the

    _________ lines.fuel

    reduces

    burners

    valve

    purge

  • 5/25/2018 Furnace Start-up and Shutdown

    41/47

    EMERGENCY SHUTDOWN

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    Emergency shutdown is called for when furnace operations becomes

    seriously abnormal.

    In order to act wisely, you must know the maximum allowable temperature

    and pressure of the _________ metal.

    You must know the maximum allowable _____________ for the firebox,

    breeching, and the stack.

    You must be ready to stop combustion by removing one or more of the three

    elements of combustion, ___________ air, or heat.

    You must know in advance that emergency block and blowdown valves are in

    working order and how to reach them in an emergency. These emergency

    controls are located in a protected area where they can be reached with

    _________________ risk.

    fuel

    tube

    temperature

    minimum, or little

  • 5/25/2018 Furnace Start-up and Shutdown

    42/47

    REVERSING THE PROCESS OF COMBUSTION

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    You can ordinarily keep fuel oil and gas out of the firebox by closing the

    burner _____________. You may have to go back to the block valves or the

    header block valve. These valves stop the fuel to all _________.

    In normal operation, you do not think of the charge as fuel. In the event of a

    tube rupture, the charge enters the firebox from the ruptured tube and

    burns. Then you must think of charge as ____________.

    Since the charge is under pressure, a tube rupture may dump large amounts

    of the charge into the firebox. Shutting off the charge and dumping it from

    the furnace does not get rid of what is in the _____________.

    The oil is best disposed of by burning it where it is, since the firebox is built to

    support the heat of burning. To keep temperatures from running too high

    during this combustion, you may need to control the __________ supply.air

    valves

    fuel

    burners

    firebox

  • 5/25/2018 Furnace Start-up and Shutdown

    43/47

    REVERSING THE PROCESS OF COMBUSTION

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    You may have to choose which of the three elements of combustion to

    control or get rid of, or try to eliminate all the three at once.

    Stop or control the __________ Restrict the _______

    Cool and put out any source of ____________ that is present

    A tube rupture may suddenly admit a large amount of fuel into the firebox.

    Your action will depend upon how serious the situation is and how well you

    can control temperatures. If the leak is small, the charge may be left in the

    ____________ tubes while the unit is circulated down.

    The furnace must be isolated and depressured if the rupture is large. Shut off

    the burner fires. Dump the furnace and cool the tubes by turning steam into

    them. Then ___________ the firebox with steam.purge

    fuelair

    ignition

    furnace

  • 5/25/2018 Furnace Start-up and Shutdown

    44/47

    REVERSING THE PROCESS OF COMBUSTION

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

    Improper operation of oil burners could lead to large amounts of oil burning on the

    floor of the furnace. Correct the burner operation. If temperatures become excessive,

    restrict the input of ______ by adjusting the stack damper.

    Flammable liquid in the fuel gas line may fill the firebox with uncontrolled flames.

    Drain the fuel gas system. If temperatures become excessive, adjust the stack damper

    to restrict the input of ______.

    Cool the firebox with steam. If temperatures still rise in the tubes beyond themaximum, block off the furnace and dump the ___________. Put steam into the

    tubes.

    An operator who has worked successfully through an emergency shutdown has new

    knowledge of himself and his _______________________.

    By deliberately applying your knowledge and measuring your actions by the severity

    of the emergency, you turn each ___________ into experience that prepares you

    better for all furnace operating situations.

    emergency

    air

    air

    charge

    equipment, or furnace

    WHAT MAY GO WRONG?

  • 5/25/2018 Furnace Start-up and Shutdown

    45/47

    WHAT MAY GO WRONG?

    PARADEEP REFINERY PROJECT

    Furnace Explosions can occur with any or a combination of the

    following

    Loss of Flame in one or more burners while the others are in operationAccumulation of Combustible gasses inside the furnace followed by

    formation of explosive mixture inside the box

    Complete Flame-out followed by an attempt to light a burner

    Accumulated Hydrocarbons inside the furnace after Flame-out forms

    explosive mixture and explodes while re-ignitionFuel Leakage into an idle furnace ignited by a source of ignition

    Fuel leakage into the Idle furnace due to passing of fuel gas block valves

    leading to formation of Explosive mixture

    Repeated attempts to light-off the furnace without properly purging the box

    Accumulation of Hydrocarbons due to delay in ignition of burners due to

    problem of igniter or flow of excessive combustion airMomentary loss of flame followed by delayed ignition

    After burn causes sudden rise in pressure in the convection section or the

    flue gas duct causing damages

    A Sunrise Project for a Sunshine Future

    QUERIES

  • 5/25/2018 Furnace Start-up and Shutdown

    46/47

    QUERIES

    PARADEEP REFINERY PROJECTA Sunrise Project for a Sunshine Future

  • 5/25/2018 Furnace Start-up and Shutdown

    47/47