2
filtec Asia Ltd Flat 4-6, 3/F, Block B, Shatin Industrial Centre, 5-7 Yuen Shun Circuit, Shatin, Hongkong. Tel.+852 2637 7100 Fax +852 2637 7411 www.filtec-asia.com FMS Training Assessment 1) What are the functions of the Filler Management System perform a. Detect Low fill, High fill & Missing cap bottle and reject it b. Monitor Low fill & High fill valves; detect problem valves in earlier state and correct the problem immediately, so to prevent product loss during the production. c. Perform filler and capper sampling during high speed production. d. All above answer a, b & c …………………………………………………..( ) 2) The X-Ray System is use for ….. a. Low fill inspection b. Over fill inspection c. Both Low & Over fill inspection d. None of the above …………………………………………………………….( ) 3) The RF System is use for …… a. Low fill inspection b. Over fill inspection c. Both Low & Over fill inspection d. None of the above …………………………………………………………….( ) 4) State all types of sampling function the FMS can provide a. Consecutive and Random sampling for both filler and capper b. Consecutive and Random sampling for filler only c. Consecutive and Random sampling for capper only d. Consecutive sampling for both filler and capper …………………………..( ) 5) N1 is the sensor offset setting from… a. Capper head one to outfeed sensor b. Valve one sensor to outfeed sensor c. Outfeed sensor to Trigger sensor d. Valve one sensor to head one sensor…………………………………… ( )

FMS Assessment

Embed Size (px)

DESCRIPTION

FMS Assessment

Citation preview

  • filtec Asia Ltd Flat 4-6, 3/F, Block B, Shatin Industrial Centre, 5-7 Yuen Shun Circuit, Shatin, Hongkong.

    Tel.+852 2637 7100 Fax +852 2637 7411 www.filtec-asia.com

    FMS Training Assessment

    1) What are the functions of the Filler Management System perform a. Detect Low fill, High fill & Missing cap bottle and reject it b. Monitor Low fill & High fill valves; detect problem valves in earlier state and

    correct the problem immediately, so to prevent product loss during the production.

    c. Perform filler and capper sampling during high speed production. d. All above answer a, b & c ..( )

    2) The X-Ray System is use for .. a. Low fill inspection b. Over fill inspection c. Both Low & Over fill inspection d. None of the above .( )

    3) The RF System is use for a. Low fill inspection b. Over fill inspection c. Both Low & Over fill inspection d. None of the above .( )

    4) State all types of sampling function the FMS can provide a. Consecutive and Random sampling for both filler and capper b. Consecutive and Random sampling for filler only c. Consecutive and Random sampling for capper only d. Consecutive sampling for both filler and capper ..( )

    5) N1 is the sensor offset setting from a. Capper head one to outfeed sensor b. Valve one sensor to outfeed sensor c. Outfeed sensor to Trigger sensor d. Valve one sensor to head one sensor ( )

  • filtec Asia Ltd Flat 4-6, 3/F, Block B, Shatin Industrial Centre, 5-7 Yuen Shun Circuit, Shatin, Hongkong.

    Tel.+852 2637 7100 Fax +852 2637 7411 www.filtec-asia.com

    Name all the above items 1 to 8

    1) _____________________________ 2) _____________________________

    3) _____________________________ 4) _____________________________

    5) _____________________________ 6) _____________________________

    7) _____________________________ 8) _____________________________