The Walker Group Architecture, IncPO Box 541, New Bern, NC 28563252.636.8778 (PHONE)252.636.8992 (FAX)
WALKERGROUP
i n c o r p o r a t e d
the
ARCHITECTURE
DISCLOSURE OF INFORMATIONCONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE,DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL
SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION
TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
FIRE ALARM AND MASS NOTIFICATION LEGEND
FIRE ALARM MANUAL PULL STATION, 48" AFF TO ACTUATING ARM, UON
FIRE ALARM/MNS AUDIO/VISUAL (SPEAKER/STROBE)APPLIANCE, 80" AFF, OR 6" BELOW FINISHED CEILING,WHICHEVER IS LOWER, UON. SUBSCRIPT INDICATESMINIMUM CANDELA RATING OF STROBE.
SPRINKLER SYSTEM SUPERVISORY FLOW SWITCH CONNECTION
F
S
F
S
15
FIRE ALARM SYSTEM PHOTOELECTRIC SMOKE DETECTOR, CEILING MOUNTED
F15 STROBE ONLY APPLIANCE, 80" AFF OR 6" BELOW FINISHED
CEILING WHICHEVER IS LOWER, UON. SUBSCRIPT INDICATESMINIMUM CANDELA RATING OF STROBE.
H FIRE ALARM SYSTEM HEAT DETECTOR
REQ'D REQUIREDPNL PANEL
NATIONAL ELECTRICAL CODENEC
GROUNDGND
EXIST EXISTING EXISTING TO REMAINETRCONDUIT C
UNLESS OTHERWISE NOTEDUON
FIRE ALARM/ MASS NOTIFICATION SYSTEM
AREA OF REFUGE ASSISTANCEARA
ABBREVIATIONS
ABOVE FINISHED GRADEAFGABOVE FINISHED FLOORAFF
FMCP
BELOW FINISHED GRADEBFG
FIRE ALARM/MASS NOTIFICATIONCONTROL PANEL
SWP
FIRE ALARM AUDIO (SPEAKER) APPLIANCE, 80" AFG, WALL MOUNT,SUBSCRIPT "WP" INDICATES WEATHER PROOF. PROVIDE COOPERWHEELOCK SERIES STH-15S OR APPROVED EQUAL.
MASS NOTIFICATION SYSTEMMNS
FIRE ALARM CONTROL PANELFACP
GENERAL FIRE ALARM NOTESFIRE ALARM DEMOLITION NOTESGENERAL: DEMOLITION DRAWINGS ARE BASED ON EXISTING PLANS AND FIELDINVESTIGATION PRIOR TO DEMOLITION. VISIT THE EXISTING BUILDING PRIOR TO BID INORDER TO BECOME FAMILIAR WITH THE EXISTING CONDITIONS AND IN ORDER TOAVOID CONFLICTS. THE CONTRACTOR MUST PROTECT AND PRESERVE ALL EXISTINGWORK NOT PART OF PROJECT.
DASHED ITEMS: ITEMS SHOWN DASHED ON DEMOLITION PLANS ARE EXISTING ANDMUST BE REMOVED.
SOLID ITEMS: ITEMS SHOWN SOLID ON DEMOLITION PLANS ARE EXISTING TO REMAIN.
EXISTING CONDUIT: EXISTING CABLING MUST BE REPLACED. EXISTING CONDUITS THATWILL NOT BE REUSED MUST BE REMOVED WHERE THEY WILL BE EXPOSED UPONCOMPLETION OF NEW WORK. EXISTING CONDUIT TO REMAIN CONCEALED IN WALLSMUST BE ABANDONED. EXISTING CONDUIT TO REMAIN BELOW FLOOR SLAB MUST BECUT OFF ONE INCH BELOW ROUGH FLOOR AND GROUTED FLUSH. REMOVE WIRINGFROM CONDUIT THAT IS ABANDONED.
REPAIR DAMAGE: EXERCISE CARE IN REMOVAL OF DEMOLITION ITEMS. REPAIR, AT NOADDITIONAL COST TO THE OWNER, ANY DAMAGE CAUSED TO EXISTINGCONSTRUCTION AND/OR EQUIPMENT TO REMAIN.
DEMOLISHED MATERIALS: MATERIALS REMOVED UNDER DEMOLITION, NOT TO BERELOCATED OR DESIGNATED TO BE TURNED OVER TO THE OWNER, WILL BECOME THEPROPERTY OF THE CONTRACTOR AND MUST BE REMOVED COMPLETELY FROM THESITE.
SCHEDULE OUTAGES: SCHEDULED OUTAGES MUST BE COORDINATED THROUGH THEGOVERNMENT CONSTRUCTION MANAGER OR CONTRACTING OFFICER.
NOTIFICATION: NOTIFY THE GOVERNMENT CONSTRUCTION MANAGER ORCONTRACTING OFFICE PRIOR TO TURNING OFF CIRCUITS.
GENERAL: UNLESS SPECIFICALLY INDICATED OTHERWISE, WORK SHOWN ON FIREALARM DRAWINGS IS NEW WORK TO INCLUDE THE FIRE ALARM/MASS NOTIFICATIONPANEL, DEVICES, AND APPLIANCES ON DRAWINGS FOR A COMPLETE ANDOPERATIONAL SYSTEM.
COORDINATION: THE CONTRACTOR MUST REVIEW CONTRACT DOCUMENTSINCLUDING FIRE ALARM DRAWINGS AND SPECIFICATIONS. CONTRACTOR MUSTCOORDINATE AND ADJUST ACCORDINGLY AS DIRECTED BY THE COTR.
AS-BUILT DRAWINGS: SECURE AN EXTRA SET OF DRAWINGS TO BE KEPT ON SITEAND MARK DAILY, THE DRAWINGS IN RED AS THE PROJECT PROGRESSES IN ORDERTO KEEP AN ACCURATE RECORD OF ALL DEVIATIONS BETWEEN THE WORK SHOWNON THE DRAWINGS AND THE WORK WHICH IS ACTUALLY INSTALLED. THESE MARKEDDRAWINGS MUST REFLECT ANY AND ALL CHANGES AND REVISIONS TO THEORIGINAL DESIGN WHICH EXISTS IN THE COMPLETED WORK. DELIVER THE MARKEDDRAWINGS TO THE COTR AT PROJECT CLOSE-OUT. IN ADDITION, PROVIDE CONTACTID POINT DESCRIPTIONS FOR EACH DEVICE.
INSPECTIONS: ARRANGE NECESSARY INSPECTIONS. DELIVER REQUIREDINSPECTION CERTIFICATES TO THE GOVERNMENT.
LABELING: ALL CONDUIT, JUNCTION/BACKBOXES, COVERS AND COUPLINGS, WHENPROVIDED, MUST BE FACTORY PAINTED RED IN UNFINISHED AREAS (E.G. ABOVECEILINGS, MECHANICAL ROOMS, ETC.). ALL CONDUIT, JUNCTION/BACKBOXES,COVERS AND COUPLINGS, WHEN PROVIDED, ARE PERMITTED TO BE PAINTED TOMATCH THE ROOM FINISHING IN FINISHED AREAS. THE INSIDE COVER OR THEJUNCTION BOX MUST BE IDENTIFIED AS "FIRE ALARM" AND THE CONDUIT MUST HAVEPAINTED RED BANDS 3/4" WIDE AT 20' INTERVALS ON BOTH SIDES OF ALL FLOOR,WALL, AND CEILING PENTRATIONS. LABEL ALL JUNCTION BOXES WITH CIRCUITDESIGNATIONS OF THE CABLING INSIDE. PROVIDE LEGIBLE TYPED LABEL ON ALLADDRESSABLE DEVICES TO INDICATE ITS ADDRESS. FOR ANY DEVICE LOCATEDABOVE ACCESSIBLE CEILING, ATTACH A LEGIBLE TYPED LABEL TO THE CEILING GRIDINDICATING THE DEVICE NOMENCLATURE AND ADDRESS.
WORKING CLEARANCE: COORDINATE FINAL LOCATIONS OF FIRE ALARM EQUIPMENTWITH MECHANICAL DUCTWORK, PIPING ETC. AND ASSURE WORKING CLEARANCEWILL BE MET. SUFFICIENT ACCESS AND WORKING SPACE MUST BE PROVIDED ANDMAINTAINED AROUND FIRE ALARM EQUIPMENT AS REQUIRED BY THE NATIONALELECTRICAL CODE. CONTRACTOR MUST COORDINATE FINAL LOCATION OFEQUIPMENT PROVIDED.
FIRE ALARM REMOTE ANNUNCIATOR PANELFAA
MOUNTING HEIGHTS: MOUNTING HEIGHTS INDICATED ARE FROM THE FINISHEDFLOOR TO THE CENTERLINE OF THE DEVICE UNLESS OTHERWISE NOTED.
FIRE STOPPING: FOR WALL OR FLOOR PENETRATIONS THROUGH FIRE-RATEDSTRUCTURES PROVIDE FIRE-STOPPING TO SEAL THE PENETRATIONS AFTER THECONDUIT HAS BEEN INSTALLED. FIRE STOPPING FOR PENETRATIONS MUST BE ULAPPROVED PER THE PENETRATION MADE IN ORDER TO MAINTAIN FIRE-RATEDINTEGRITY OF THE STRUCTURE.
FIRE ALARM COORDINATION: THE ELECTRICAL CONTRACTOR MUST COORDINATEWITH THE FIRE ALARM SYSTEM PROVIDER AND PROVIDE POWER CONNECTIONS TOCOMPONENTS WHETHER SHOWN OR NOT. MANUFACTURERS REQUIRE VARYINGQUANTITIES OF POWER CONNECTIONS FOR EQUIPMENT LIKE EXPANDER PANELSAND POWER SUPPLIES. THESE DEVICES ARE DEPENDENT UPON THE SPECIFICMANUFACTURERS SYSTEM. THE FIRE ALARM SYSTEM SUPPLIER MUST NOTIFY THEOTHER APPROPRIATE SUB-CONTRACTORS ABOUT THESE REQUIREMENTS ANDCONNECTION MUST BE PROVIDED AS PART OF THE PROJECT.
FIRE ALARM EQUIPMENT SURVIVAL: A SMOKE DETECTOR IS REQUIRED AT ALLCONTROL PANEL LOCATIONS (I.E. FIRE ALARM PANEL, NOTIFICATION EXTENDERPANELS, TRANSMITTERS, ETC.). CONTRACTOR MUST PROVIDE SYSTEM SMOKEDETECTORS FOR ALL LOCATIONS OF FIRE ALARM PANELS, TO INCLUDE THOSESHOWN AND THOSE THAT ARE ADDED BY THE CONTRACTOR FOR THEIR SPECIFICDESIGN.
CONDUIT: ALL ADDED FIRE ALARM/MASS NOTIFICATION SYSTEM WIRING MUST BEINSTALLED IN CONDUIT (EMT MINIMUM). EXISTING EMT MAY BE REUSED WHERE ITSATISFIES REQUIREMENTS OF NFPA 70.
CONDUIT SEALS: PROVIDE CONDUIT SEAL IN ACCORDANCE WITH NFAP 70 300.7 TORACEWAYS EXPOSED TO DIFFERENT TEMPERATURES.CONDUCTORS: ALL CONDUCTORS MUST BE REPLACED WITH NEW.
INTELLIGIBILITY LEVEL: CONTRACTOR MUST VERIFY INTELLIGIBILITY LEVEL BYMEASUREMENT AFTER INSTALLATION OF 0.7 CIS FOR NAVY AND MARINE CORPPROJECTS. COMMERCIALLY AVAILABLE TEST INSTRUMENTATION MUST BE USED TOMEASURE INTELLIGIBILITY AS SPECIFIED BY IEC 60849 AND IEC 60268-16. THE MEANVALUE OF AT LEAST THREE READINGS MUST BE USED TO COMPUTE THEINTELLIGIBILITY SCORE AT EACH TEST LOCATION.
DA
CT
(2) CAT6 UTP TO TELEPHONE PATCH PANELFINAL TERMINATIONS BY GOVERNMENT
PATCH PANEL
NETWORKTELEPHONE
TO
EXISTING EQUIPMENT3/4" CONDUITW/ PULL STRING
EXISTINGEXTERNALANTENNA
125'
MAX
IMUM
CAB
LE L
ENGT
H
25' MAXIMUM
DEDICATED 120V, 20A CIRCUITFROM SAME SOURCE THATFEEDS FACP.
FIRE ALARM/MASS NOTIFICATION SYSTEM RISER DIAGRAM
S F S H
TO OTHER ADDRESSABLEDEVICES
PRIMARY + BACKUP (2) CAT6 UTP (BLUE)
WP
TO OTHER ADDRESSABLEDEVICES
FAA
D
RTTO AHUSHUTDOWN
1. THE FACP IS AN EXISTING COMBINED FIRE ALARM ANDMASS NOTIFICATION SYSTEM IN THE CHAPEL BUILDING17. PROVIDE NEW SUB-PANEL FACP IN BUILDING 17A ANDNETWORK BACK TO THE EXISTING FACP IN BULDING 17.
2. THE NETWORKED FIRE ALARM AND DETECTION SYSTEMIS TO BE FULLY COMPLIANT WITH THE CURRENTEDITIONS OF UFC 3-600-01, UFC 3-600-10N, UFC 4-021-01,AND NFPA 72 FOR A FIRE ALARM AND AN EMERGENCYVOICE ALARM COMMUNICATION SYSTEM. THE SYSTEM ISDESIGNED TO INTERFACE WITH THE SITE MNS.
3. THE FACP MUST BE CAPABLE OF ACCEPTING 10 VOLTSROOT MEAN SQUARED (VRMS), 25 VRMS, 70.7 VRMSAND/OR LINE LEVEL (.707 VRMS) AUDIO INPUTS.
4. FACP MUST BE CONFIGURED TO ACCEPT DRY CONTACTINPUT FROM AN EXTERNAL INTERFACE TO ALERT THEFIRE ALARM PANEL THAT A MNS MESSAGE ISFORTHCOMING. THE FIRE ALARM PANEL MUST BECONFIGURED SO THAT WHILE THIS INPUT IS ACTIVE(CONTACT CLOSED) THE FIRE ALARM PANEL MUSTROUTE AUDIO PROVIDED BY THE MNS INTERFACEDIRECTLY TO ALL CONNECTED FIRE ALARM SPEAKERS.THE SYSTEM MUST BE PROGRAMMED SO THIS EXTERNALAUDIO INPUT WILL RECEIVE HIGHEST PRIORITY ANDOVERRIDE ALL FIRE ALARM NOTIFICATION SO LONG ASTHE INPUT IS ACTIVE. WHEN THE INPUT GOES INACTIVE(CONTACT OPEN) THE EXTERNAL AUDIO ROUTING WILLCEASE AND THE FIRE ALARM PANEL MUSTAUTOMATICALLY RETURN TO THE PRIOR NOTIFICATIONPROGRAM THAT WAS ACTIVE BEFORE THE MNSMESSAGE.
5. FACP MUST BE COMPATIBLE AND OPERABLE WITH THEEXISTING FIRE ALARM SUPERVISING STATIONSHUREGUARD III. EXISTING BASEWIDE MASSNOTIFICATION REPORTING SYSTEM IS A COOPERINDUSTRIES WAVES SYSTEM. CONTRACTOR MUSTPROVIDE ALL EQUIPMENT AND LABOR REQUIRED TOCONNECT THE NEW FIRE ALARM AND DETECTIONSYSTEM TO THE BASE'S SUPERVISING STATION. WAVESSYSTEM TRANSCEIVER TO BE PROVIDED BY THEGOVERNMENT.
6. DACT MUST BE CONFIGURED TO TRANSMIT SIGNALS INCONTACT ID FORMAT.
7. SIGNALS TRANSMITTED OVER THE PRIMARY ANDSECONDARY MEANS OF TRANSMISSION MUST BE POINTSPECIFIC WITH EACH ADDRESS AND CONDITIONINDICATED AT THE FIRE ALARM PANEL TRANSMITTEDSEPARATELY. ALL FIRE ALARMS, SUPERVISORY ALARMS,AND TROUBLE CONDITIONS MUST BE TRANSMITTED TO
THE SUPERVISING STATION. CONNECTION TO THE FIREALARM REPORTING SYSTEM AND PROGRAMMING OF THEDACT MODULE AND HEAD END EQUIPMENT SHUREGUARDIII MUST BE COORDINATED WITH THE FIRE ALARMREPORTING SYSTEM (FARS) ADMINISTRATOR.
8. PROVIDE A DOCUMENT CABINET ADJACENT TO FACP.CABINET MUST BE STEEL, LOCKING, WITH AHINGE-MOUNTED DOOR, KEYED THE SAME AS THE FACP.PROMINENTLY LABEL THE EXTERIOR OF THE CABINET"SYSTEM RECORD DOCUMENTS". CABINET MUSTINCLUDE PAPER COPIES AND A CD OF FIRE ALARMAS-BUILT DRAWINGS, LIST OF CONTACT ID DESCRIPTIONSFOR THE FIRE ALARM ADDRESSABLE DEVICES, NFPA 72RECORDS OF COMPLETION. CD MUST INCLUDESITE-SPECIFIC SOFTWARE AND O&M MANUALS STOREDIN A CD JEWEL CASE. PROVIDE A LAMINATED GRAPHICFLOOR PLAN SIZE 22"X34" ADJACENT TO THE FACP ANDMAIN ENTRANCE TO BUILDING ADJACENT TO THEANNUNCIATOR. THE DRAWING MUST DEPICT ALL FIREALARM DEVICES, REMOTE POWER SUPPLY PANELS, ANDASSOCIATED EQUIPMENT WITHIN THE FACILITY. THEDRAWING MUST ALSO INCLUDE ROOM NUMBERS.
9. FIRE ALARM PLANS INDICATE AREA OF STROBECOVERAGE AND ARE DIAGRAMMATIC ONLY.CONTRACTOR IS RESPONSIBLE FOR PROVIDINGADDITIONAL SPEAKERS FOR EACH FACILITY TO MEET ALLMASS NOTIFICATION SYSTEM INTELLIGIBILITYREQUIREMENTS IN ACCORDANCE WITH UFC 4-021-01.
10. INSTALL COOPER WHEELOCK SERIES STH-155SUPERVISED HORN LOUDSPEAKER OUTSIDE OFBUILDING.
11. LABEL ALL DEVICES WITH THEIR ADDRESSES.
12. PROVIDE ACCESS FOR THE CAMP LEJEUNE FIRE ANDEMERGENCY SERVICES FIRE ALARM TECHNICIANS TOUNINSTALL AND RETRIEVE FIRE ALARM PANELS,SYSTEMS AND COMPONENTS PRIOR TO THE DEMOLITIONOF EXISTING BUILDINGS, POC IS DAVID JONES (910)376-0437.
FIRE ALARM AND MNS MONITORING NOTES
EXISTING4100ES
NO SCALEFIRE ALARM/MASS NOTIFICATION INPUT-OUTPUT MATRIX
ACTU
ATE
COM
MON
ALA
RM S
IGNA
L
ACTU
ATE
AUDI
BLE
ALAR
M S
IGNA
L
ACTU
ATE
COM
MON
SUP
ERVI
SORY
SIG
NAL
INDI
CATO
R
ACTU
ATE
AUDI
BLE
SUPE
RVIS
ORY
SIGN
AL
ACTU
ATE
COM
MON
TRO
UBLE
SIG
NAL
INDI
CATO
R
ACTU
ATE
AUDI
BLE
COM
MON
TRO
UBLE
SIG
NAL
ACTI
VATE
DIS
PLAY
ON
FACP
AND
ANN
UNCI
ATOR
S
ACTU
ATE
AUDI
BLE
EVAC
UATI
ONSI
GNAL
S &
VOIC
E M
ESSA
GE
ACTI
VATE
VIS
UAL
EVAC
UATI
ON S
IGNA
LS
TRAN
SMIT
FIR
E AL
ARM
SIG
NAL
TO S
UPER
VISI
NG S
TATI
ON
TRAN
SMIT
SUP
ERVI
SORY
SIG
NAL
TO S
UPER
VISI
NG S
TATI
ON
TRAN
SMIT
TRO
UBLE
SIG
NAL
TO S
UPER
VISI
NG S
TATI
ON
OVER
RIDE
OTH
ER M
ESSA
GES,
ACT
IVAT
EAU
DIBL
E AN
D VI
SUAL
SIG
NALS
CONTROL UNIT ANNUNCIATION NOTIFICATION SUPP.
SYSTEM INPUTS BELOW A B C D E F G H I J K L M1 MANUAL FIRE ALARM BOXES X X X X X X 12 SMOKE DETECTORS X X X X X X 23 34
WATERFLOWS X X X X X X4
5SPRINKLER CONTROL VALVES TAMPER SWITCH X X X X
56
FIRE ALARM AC POWER FAILURE X X X X6
7FIRE ALARM SYSTEM LOW BATTERY X X X X
78
OPEN CIRCUIT X X X X8
9GROUND FAULT X X X X
910
NOTIFICATION APPLIANCE CIRCUIT SHORT X X X X10
11BASEWIDE MASS NOTIFICATION MESSAGE ACTIVE X
11A B C D E F G H I J K L M
SYSTEM OUTPUT BELOW
LOCAL OPERATING CONSOLE (LOC) X
TRX-401TRANSCEIVER
SFSWP
SF F S
FINISHED WALL
WALL MOUNTEDSMOKE/HEAT DETECTOR
CEILING MOUNTEDSMOKE/HEAT DETECTORACCEPTED HERE
4"12"
MAX
CEILING3' MINIMUM
A/C SUPPLY ORRETURN DIFFUSER
MAGNETICDOORHOLDER 5"
DOORWIDTHLESS 3"
MANUALPULLSTATION
TO EXIT DOOR5' MAXIMUM
FIREPHONEJACK 42"MIN TO 48" MAX
TO TOP OF PULLHANDLE
92" MIN AFF
AUDIBLEONLYAUDIBLE/VISUAL &
VISUAL ONLYAPPLIANCES
SYNCHRONIZE MORETHAN TWO
APPLIANCES IN ANYFIELD OF VIEW.
F I R EF I R E
FOR CEILING HEIGHTS LESS THAN 86" THEVISUAL LENS MOUNTING HEIGHT MUST BE
WITHIN 6" OF THE CEILING
96"MAXIMUM
AFF
80"MINIMUM
AFF
FINISHED FLOOR
NO SCALEFIRE ALARM SYSTEM DEVICE MOUNTING HEIGHT DETAILNO SCALE
NOTE: MEASUREMENTSSHOWN ARE TO THE CLOSESTEDGE OF THE DETECTOR
6" MINIMUM BFC
NO SCALENO SCALE
LOCAL OPERATORS CONSOLELOC
D DUCT SMOKE DETECTOR
REMOTE TEST / RESET DEVICERT
02/24/20
EXISTING CHAPEL( BUILDING 17 )
ADDITION ( BUILDING 17A )
SF
TO OTHERADDRESSABLEDEVICES
F S H D
RTTO AHUSHUTDOWN
TO OTHERADDRESSABLEDEVICESS
WP
SS
120VAC
MNSREMOTE
NEW FACP
1
2
3
4
5
6
7
8
F SS
F RT S
H
D
SS
RT
SHS
DFACP
1
SSWP F LOC
FAA
F S
F S WP
SWP
101VESTIBULE
102CONFESSIONAL
103SANCTUARY
104ALTAR
105
CHANGINGROMM
106CORR.
109JAN.
108UNISEX
107ELEC.
8
S
201
STORAGEMEZZANINE The Walker Group Architecture, Inc
PO Box 541, New Bern, NC 28563252.636.8778 (PHONE)252.636.8992 (FAX)
WALKERGROUP
i n c o r p o r a t e d
the
ARCHITECTURE
DISCLOSURE OF INFORMATIONCONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE,DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL
SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION
TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
NDEMOLITION FIRST FLOOR PLANSCALE: 1/8" = 1'-0"
NDEMOLITION MEZZANINE FLOOR PLANSCALE: 1/8" = 1'-0"
1 REMOVE EXISTING FIRE ALARM CONTROL PANEL TO BE RELOCATED.REFER TO SHEET FA101 FOR NEW LOCATION.
NOTES THIS SHEET
DUE TO THE REMOVAL AND RELOCATION OF THE EXISTING FACP, THE FIRE ALARM SYSTEM MUST UNDERGO AS MUCHMINIMAL DOWN TIME AS POSSIBLE. IF THIS DOWNTIME WERE TO OCCUR AFTER CONSTRUCTION HOURS, CONTRACTORMUST COORDINATE WITH CAMP LEJEUNE PERSONNEL TO CONDUCT FIRE WATCH DURING THESE HOURS.
FIRE ALARM/MASS NOTIFICATION OPERATION NOTE:
02/24/20
1
2
3
4
5
6
7
8
20 CF
0.5
SWP
SF RT S
H
D
SS
RT
FHS
D
SSWP F LOC
FAA
F S
F S WP
FACP
S15
S15
F15
F15
S
S
SWP
SWP
SWP
SWP
SWP
S75
S75
F15
S15
SWP
S H
F
F
F
F
F
S15
F
F15
NAC
1
101VESTIBULE
103CONFESSIONAL102
STORAGE
104CHAPEL
105ALTAR
109CORRIDOR
108STORAGE
106VESTIBULE
107UNISEX
110MECH.
311BABYSITTING
313PANTRY
314KITCHEN
304FELLOWSHIP HALL
305MENS 306
WOMENS
310TELECOM 309
MECH/ELEC.
308OFFICE
307OFFICE
301VESTIBULE
302CORRIDOR
303JAN.
312UNISEX
LOC
2
S75
8
S
The Walker Group Architecture, IncPO Box 541, New Bern, NC 28563252.636.8778 (PHONE)252.636.8992 (FAX)
WALKERGROUP
i n c o r p o r a t e d
the
ARCHITECTURE
DISCLOSURE OF INFORMATIONCONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE,DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL
SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION
TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.NCONSTRUCTION FIRST FLOOR PLANSCALE: 1/8" = 1'-0"
1
2
REINSTALL FIRE ALARM CONTROL PANEL THIS LOCATION. REWORK/EXTENDCIRCUITRY AS NEEDED. TESTING OF SYSTEM MUST BE DONE UPONCOMPLETION OF PROJECT TO ENSURE INTEGRITY OF SYSTEM WAS KEPTINTACT DURING CONSTRUCTION.
PROVIDE (1) 1-1/4"C, SCH. 80 PVC DIRECT BURIED 24" BFG, WITH 2/C, 18AWGSTP, OSP RATED CABLE FROM EXISTING FACP TO NOTIFICATION EXTENDERPANEL IN NEW ADDITION.
NOTES THIS SHEET
NNEW WORK MEZZANINE FLOOR PLANSCALE: 1/8" = 1'-0"
02/24/20
The Walker Group Architecture, IncPO Box 541, New Bern, NC 28563252.636.8778 (PHONE)252.636.8992 (FAX)
WALKERGROUP
i n c o r p o r a t e d
the
ARCHITECTURE
DISCLOSURE OF INFORMATIONCONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE,DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL
SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION
TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
LEGEND & ABBREVIATIONS
TELECOMMUNICATIONS
TELECOMMUNICATIONS BACKBOARD
4" CONDUIT SLEEVE
DDC OUTLET, 5"X5"X2 7/8"D BOX WITH SINGLE GANG PLASTER RING
AND SINGLE GANG COVERPLATE TO MATCH ELECTRICAL OUTLET
COVERPLATE MATERIAL AND COLOR, COORDINATE MOUNTING HEIGHT
WITH DDC VENDOR PRIOR TO INSTALLATION, WITH 1 1/4"C WITH (1) 2
STRAND, SMFO CABLE. STUB CONDUIT TO CABLE TRAY AND
TERMINATE WITH GROUNDING BUSHING. CONTINUE CABLING IN CABLE
TRAY TO TELECOM ROOM.
TELEPHONE OUTLET, 5"X5"X2 7/8"D BOX WITH SINGLE GANG
PLASTER RING AND SINGLE GANG COVERPLATE TO MATCH
ELECTRICAL OUTLET COVERPLATE MATERIAL AND COLOR, 46"
AFF, UON, WITH 1 1/4"C WITH (1) CAT6 UTP CABLE (GREEN VOICE),
STUB CONDUIT TO CABLE TRAY AND TERMINATE WITH
GROUNDING BUSHING. CONTINUE CABLING IN CABLE TRAY TO
TELECOM ROOM.
GENERAL SPECIAL SYSTEMS
THE GENERAL CONTRACTOR SHALL PROVIDE A COMPLETION SCHEDULE, BROKEN DOWN
BY VARIOUS CONSTRUCTION PHASES, FOR TURN OVER OF COMPLETED ROUGH-IN FOR
CONTRACTOR TO FINISH WORK. THE CONTRACTOR SHALL COORDINATE TURN OVER WITH
VENDORS, AND SHALL TURN OVER AREAS WITH ADEQUATE TIME FOR VENDOR FINISH
WORK. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY EXTRA VENDOR COST
RESULTING FROM INCORRECT SYSTEMS ROUGH-IN.
THE GENERAL CONTRACTOR SHALL PROVIDE IN-WALL REINFORCEMENT AS NECESSARY
FOR ALL SYSTEMS CABINETS, SHELVES, BRACKETS, FURNITURE MOUNTS, ETC.. AND
SHALL MOUNT CABINETS, SHELVES, BRACKETS, AND FURNITURE MOUNTS IN
ACCORDANCE WITH DRAWINGS, VENDOR SUBMITTALS, AND ALL APPLICABLE CODES.
THE CONTRACTOR SHALL COORDINATE AND PROVIDE ALL REQUIRED RACEWAY SYSTEMS
FOR ALL SPECIAL SYSTEMS INCLUDING CONDUIT WITH PULL STRING, JUNCTION BOXES,
GROUNDING, BACKBOARDS, POWER CONNECTIONS, ETC. THE CONTRACTOR SHALL
COORDINATE ALL ROUGH-IN, BOX SIZES AND CONFIGURATIONS, CONDUIT SIZES AND
ROUTING WITH THE VENDOR PRIOR TO INSTALLATION OF THE RACEWAY SYSTEM.
THE CONTRACTOR SHALL PROVIDE ALL CABLING AND WIRING (EXCEPT POWER WIRING),
CABLE TRAY, JACKS, COVER PLATE COMPATIBLE WITH THE EQUIPMENT, DEVICES, RACKS,
AND COMPONENT EQUIPMENT UNLESS OTHERWISE NOTED.
FINAL DEVICE LOCATIONS AND ELEVATIONS SHALL BE COORDINATED WITH
ARCHITECTURAL PLANS, CASEWORK AND ELEVATIONS, AND VENDOR REQUIREMENTS.
TELEPHONE AND DATA SYSTEMS
THE TELEPHONE AND DATA SYSTEMS WILL BE THROUGH THE CONTRACTOR. THE
CONTRACTOR SHALL PROVIDE A COMPLETE RACEWAY SYSTEM AS INDICATED.
ALL CONDUITS SHALL BE 1 1/4" MINIMUM, SHALL HAVE A PULL WIRE AND SHALL BE
TERMINATED WITH INSULATED GROUNDING BUSHING. ALL TELEPHONE, DATA AND CABLE
TELEVISION BOXES SHALL BE 5" X 5" X 2 7/8" DEEP WITH A SINGLE GANG RISE AND BLANK
COVER PLATE UNLESS OTHERWISE INDICATED. COORDINATE CONDUIT QUANTITIES,
SIZES AND LOCATIONS.
THE BUILDING SHALL BE PRE-WIRED BY THE VENDOR DURING CONSTRUCTION PRIOR TO
CLOSING THE WALL CAVITIES.
STUB ALL CONDUITS WITH PULL WIRE FOR COMMUNICATIONS DEVICE OUT TO CABLE
TRAY AND PROVIDE INSULATED GROUND BUSHING. WHERE A FULL WALL SEPARATES THE
CONDUIT STUB OUT FROM THE DESTINATION ROOM, PROVIDE A 1 1/2" MINIMUM SLEEVE
THROUGH THE WALL, ABOVE AN ACCESSIBLE CEILING, TO ACCOMMODATE THE CABLING.
PROVIDE ALL CONDUITS AND SLEEVES PENETRATING RATED FIRE OR SMOKE WALLS
WITH APPROVED FIRE RETARDANT TO PROVIDE A UL RATED ASSEMBLY. MAINTAIN
VENDOR RECOMMENDED SEPARATION BETWEEN WIRING OF DIFFERENT SYSTEMS AND
FROM INTERFERENCE PRODUCING ELECTRICAL DEVICES SUCH AS FLUORESCENT
LIGHTS, BALLASTS, TRANSFORMERS, RELAYS, MOTOR CONTROLS, ETC..
GENERAL SPECIAL SYSTEM NOTES
REQ'D REQUIRED
PNL PANEL
NATIONAL ELECTRICAL CODENEC
GROUNDGND
EXIST EXISTING
EXISTING TO REMAINETR
CONDUIT C
RACK UNITRU
AREA OF REFUGE ASSISTANCEARA
ABBREVIATIONS
ABOVE FINISHED GRADEAFG
ABOVE FINISHED FLOORAFF
FMCP FIRE ALARM/MASS NOTIFICATION CONTROL PANEL
BELOW FINISHED GRADEBFG
BUILDING ENTRANCE PROTECTORBEP
TELECOMMUNICATIONS MAIN GROUND BUS BARTMGB
DDC OUTLET
NO SCALE
1-1/4"C TO CABLE TRAY
DDC
BLANK
385 A 386
5" X 5" X 2 1/8" BOX
1-1/4"C TO CABLE TRAY
5" X 5" X 2 7/8" BOX
MOUNTING STUDS
(1) 4 PAIR 24 AWG COPPER
CAT 6 UTP, GREEN CABLES
(1) GREEN CAT 6 UTP RJ45
JACKS
TELECOMMUNICATIONS RISER DIAGRAM
NO SCALE
FIRST FLOOR310
(4) CAT6 UTP
(TYP. FOR ALL TELE/DATA OUTLETS)
NEW BUILDING - 17A EXISTING CHAPEL
BET BUILDING ENTRANCE TERMINAL
NOTE:
(2) 4"C, SCH. 80PVC, DIRECT BURIED 24" BFG MIN. (1) 4"C TO INCLUDE (1) 1-1/4"C WITH / (1) 3" 3-CELL MAXCELL FABRIC INNERDUCT WITH (1) 12 STRAND SMFO, OSP RATED
CABLE. (1) 4"C WITH (1) 25 PAIR COPPER TELEPHONE CABLE, OSP RATED TO RP-5. FIBER DEMARC LOCATION TO BE DETERMINED BASE TELEPHONE.
(1) 3"C., SCH.80 PVC, DIRECT BURIED 24"BFG MIN WITH (1) 3" 3-CELL MAXCELL FABRIC INNERDUCT WITH (1) 6 STRAND SMFO CABLE, OSP RATED (INSTALLED IN INNERDUCT),
WITH (1) 12 PAIR TELEPHONE CABLE, OSP RATED.
1
1
(1) 4 PAIR 24AWG COPPER
(TYP. FOR TELEPHONE ONLY OUTLETS)
DDC
106
25RU WALL MOUNTED CABINET,
FIBER OPTIC DISTRIBUTION PANEL,
CAT 6 PATH PANEL, FIBER PATCH
PANEL, CABLE MANAGMENT, FAN,
LOCKABLE.
WALL TELEPHONE OUTLET
NO SCALE
PB PULLBOX, TYPE 8. SEE DETAIL THIS SHEET.
(1) 2 STRAND SMFO CABLE
(1) DUPLEX "SC" TYPE JACK
385 A 386
BET
TMGB
PB
FREE STANDING 7'
EQUIPMENT RACK
3"PVC, SMART
TYPE ELBOW
WINDOW
TMGB
BET
2
2
COMBINATION TELEPHONE / DATA JACK
NO SCALE
(4) 4 PAIR 24 AWG COPPER CAT
6 UTP, GREEN CABLES FOR
EVEN NUMBERED JACKS
(2) DUAL MOLDED 8P8C JACKS
387 A 388
5" X 5" X 2 1/8" BOX
GREEN COMPUTER ICON -
EVEN NUMBERS
GREEN TELEPHONE
ICON - ODD NUMBERS 387 A 388
DIGITAL DATA CONTROLDDC
TELE/DATA OUTLET, 5"X5"X2 7/8"D BOX WITH SINGLE GANG PLASTER
RING AND SINGLE GANG COVERPLATE TO MATCH ELECTRICAL OUTLET
COVERPLATE MATERIAL AND COLOR, 18" AFF, UON, WITH 1 1/4"C WITH
(4) CAT 6 UTP CABLE (2 GREEN VOICE / 2 GREEN DATA). STUB CONDUIT
TO CABLE TRAY AND TERMINATE WITH GROUNDING BUSHING.
CONTINUE CABLING IN CABLE TRAY TO TELECOM ROOM.
DDC
LADDER TYPE CABLE TRAY
WIRE BASKET TYPE CABLE TRAY
1-1/4"C TO CABLE TRAY
30" X 48" X 24" DEEP
24" X 36" X 24" DEEP
12" X 24" X 24" DEEP
12" X 18" X 24" DEEP
12" X 12" X 24" DEEP
HANDHOLE SIZING
PROVIDE LABEL "ELECTRICAL" FOR POWER HANDHOLES OR "TELEPHONE" FOR TELEPHONE
PROVIDE WITH (2) 2 1/2" MOUSEHOLES.
PROVIDE STAINLESS STEEL BOLTS AND INSERTS.
10" x 10" AREA.
COVER AND BOX SHALL WITHSTAND A SERVICE LOAD OF NO LESS THAN 15,000 LBS OVER A
REINFORCING WITH COMPRESSIVE STRENGTH OF NO LESS THAN 10,000 PSI.
HOUSING SHALL BE A POLYMER CONCRETE REINFORCED WITH A HEAVY WEAVE FIBERGLASS
5.
4.
3.
2.
HANDHOLES, OR AS INDICATED.
REQUIRED
BOX WHEN
SECTIONAL
1.
HANDHOLE REQUIREMENTS
9
8
7
6
TYPE
5
CRUSHED ROCK
6"
EARTH
COMPACTED
PULL SLOT
SURFACE
RESISTANT
SKID
L
A
B
E
L
HEX BOLT AND
WASHER
STAINLESS STEEL
COVER
BOX AND
AROUND BOX
6"
CONCRETE RING
10"
6"
UG-6
JUNE 2002
(COMPOSITE/FIBERGLASS) TYPES 5, 6, 7, 8 & 9
STANDARD ELECTRICAL HANDHOLE (NONTRAFFIC)
SKETCH DATE STYLE
LADDER CABLE TRAY DETAIL
NO SCALE
NOTES:
1. CONTRACTOR SHALL PROVIDE PATHWAY FOR ALL LISTED SYSTEMS CABLING. TRAY MUST COMPLY WITH NEC FOR
CABLE TRAY FILL REQUIREMENTS. IN NO CASE MAY THE CABLE TRAY BE LESS THAN THE STATED MINIMUM SIZE.
2. MOUNT CABLE TRAY AT A MINIMUM OF 12" BELOW MECHANICAL DUCT WORK BUT AS HIGH AS POSSIBLE TO AVOID
TAMPERING.
3. TYPICAL MOUNT OVER RACKS IN TELCOM ROOM.
TYPICAL HANGER. SUPPORT FROM STRUCTURE
ABOVE. SPACE AT 60" ON CENTER AND WITHIN 24"
OF ENDS MINIMUM.
TYPICAL CONDUIT STUBBED ABOVE
CABLE TRAY WITH BUSHING. PROVIDE #6
AWG GROUND BETWEEN CONDUIT AND
#2 AWG CABLE TRAY GROUND WIRE.
TYPICAL CONDUIT STUBBED
THROUGH WALL TO ABOVE
CABLE TRAY WITH BUSHING.
PROVIDE #6 AWG GROUND
BETWEEN CONDUIT AND #2
AWG CABLE TRAY GROUND
WIRE.
SIZE AS INDICATED
CABLE TRAY
GROUND WIRE, #2.
MOUNT TO SIDE OF
CABLE TRAY.
2" MIN
G
G
G
G
#6 BOND GROUND
WIRE TO CABLE
TRAY GROUND
WIRE
#6 BOND GROUND
WIRE TO CABLE
TRAY GROUND
WIRE
NO SCALE
2" MIN.
NOTES:
2. MOUNT CABLE TRAY AT A MINIMUM OF 12" BELOW MECHANICAL DUCT WORK BUT AS HIGH AS POSSIBLE TO AVOID
TAMPERING.
3. TYPICAL MOUNTING METHOD.
PROVIDE MANUFACTURER RECOMMENDED
COUPLING TO SECURELY CONNECT AND
GROUND SECTIONS OF CABLE TRAY.
TYPICAL HANGER. SUPPORT
FROM STRUCTURE ABOVE.
SPACE AT 60" ON CENTER
AND WITHIN 24" OF ENDS
MINIMUM.
TYPICAL CONDUIT STUBBED THROUGH WALL TO
ABOVE CABLE TRAY WITH BUSHING. PROVIDE #6
AWG GROUND BETWEEN CONDUIT AND #2 AWG
CABLE TRAY GROUND WIRE.
#6 BOND GROUND
WIRE TO CABLE
TRAY GROUND
WIRE
CABLE TRAY GROUND
WIRE, #2.
MOUNT TO SIDE OF
CABLE TRAY
SIZE AS INDICATED
G
G
G
#6 BOND TO CABLE
TRAY GROUND
BONDING CLAMP
1. CONTRACTOR SHALL PROVIDE PATHWAY FOR ALL LISTED SYSTEMS CABLING. TRAY MUST COMPLY WITH UFC 3-580-1
FOR CABLE TRAY FILL REQUIREMENTS. IN NO CASE MAY THE CABLE TRAY BE LESS THAN THE STATED MINIMUM SIZE.
WIRE BASKET CABLE TRAY DETAIL - ABOVE CEILING
TYPICAL GROUND BUS BAR DETAIL
NO SCALE
LESS THAN 4 (13)
4 - 6 ( 14 - 20 )
6 - 8 ( 21 - 26 )
8 - 10 ( 27 - 33 )
10 - 13 ( 34 - 41 )
13 - 16 ( 42 - 52 )
16 - 20 ( 53 - 66 )
20 - 26 ( 67 - 84 )
26 - 32 ( 85 - 105 )
32 - 38 ( 106 - 125 )
38 - 46 ( 126 - 150 )
46 - 53 ( 151 - 175 )
53 - 76 ( 176 - 250 )
76 - 91 ( 251 - 300 )
GREATER THAN 91 ( 301 )
TBB - TELECOMMUNICATIONS BONDING BACKBONE
TBC - TELECOMMUNICATIONS BONDING CONDUCTOR
4
3
2
1
1/0
2/0
3/0
4/0
250kcmil
300kcmil
350kcmil
500kcmil
600kcmil
750kcmil
6
TBB/TBC SIZE (AWG)TBB/TBC LENGTH M (FT)
COPPER BASED BOLTS, NUTS, & LOCK
WASHERS (TYPICAL)
STAND-OFF INSULATOR, 1KV MINIMUM
(2" MINIMUM OFFSET) (TYPICAL)
COPPER MAIN TELECOMMUNICATIONS
GROUND BUS BAR ( )
4" x 12" x 1/4" THICK (TYPICAL)
TMGB
(1) #6 CU GND IN 3/4"C. CONNECT TO
ELECTRICAL PANEL GROUND ELECTRODE
SYSTEM PER NEC ARTICLE 800
TO BUILDING
STEEL
TO CABLE TRAY
TO TELECOM CABINET
MOUNTING BRACKET(S)
FACTORY DRILLED HOLES (TYPICAL)
CONTRACTOR SHALL SIZE
TELECOMMUNICATIONS GROUNDING
AND BONDING INFRASTRUCTURE
PER ANSI J-STD-607-D
EXISTING PLYWOOD BACKBOARD
8-POSITION, 8-CONDUCTORS8P8C
CATEGORYCAT
UNLESS OTHERWISE NOTEDUON
UNSHEILDED TWISTED PAIRUTP
02/24/20
BE
TT
MG
B
12" X 2" LADDER
TYPE CABLE TRAY
(2) 4"C
1
2
3
4
5
6
7
8
20 CF
E F G H
9
10
11
0.5
B.1 B.7BA C D
I J K L M N O P
DDC
101
VESTIBULE
103
CONFESSIONAL102
STORAGE
104
CHAPEL
105
ALTAR
109
CORRIDOR
108
STORAGE
106
VESTIBULE
107
UNISEX
110
MECH.
311
BABYSITTING
313
PANTRY
314
KITCHEN
304
FELLOWSHIP HALL
305
MENS
306
WOMENS
310
TELECOM
309
MECH/ELEC.
308
OFFICE
307
OFFICE
301
VESTIBULE
302
CORRIDOR
303
JAN.
312
UNISEX
PB3"C, MIN 24" BFG
1
T-101
1
6" X 2" WIRE
BASKET TYPE
CABLE TRAY
BET
TMGB
DDC
The Walker Group Architecture, IncPO Box 541, New Bern, NC 28563252.636.8778 (PHONE)252.636.8992 (FAX)
WALKERGROUP
i n c o r p o r a t e d
the
ARCHITECTURE
DISCLOSURE OF INFORMATIONCONTRACTOR SHALL COMPLY AS FOLLOWS:
(A) THE CONTRACTOR SHALL NOT RELEASE TO ANYONE OUTSIDE THE CONTRACTOR'S ORGANIZATION ANY UNCLASSIFIED INFORMATION, REGARDLESS OF MEDIUM (E.G., FILM, TAPE,DOCUMENT), PERTAINING TO ANY PART OF THIS CONTRACT OR ANY PROGRAM RELATED TO THIS CONTRACT, UNLESS-
(1) THE CONTRACTING OFFICER HAS GIVEN PRIOR WRITTEN APPROVAL; OR(2) THE INFORMATION IS OTHERWISE IN THE PUBLIC DOMAIN BEFORE THE DATE OF RELEASE(B) REQUESTS FOR APPROVAL SHALL IDENTIFY THE SPECIFIC INFORMATION TO BE RELEASED, THE MEDIUM TO BE USED, AND THE PURPOSE FOR THE RELEASE. THE CONTRACTOR SHALL
SUBMIT ITS REQUEST TO THE CONTRACTING OFFICER AT LEAST 45 DAYS BEFORE THE PROPOSED DATE FOR RELEASE.(C) THE CONTRACTOR AGREES TO INCLUDE A SIMILAR REQUIREMENT IN EACH SUBCONTRACT UNDER HIS CONTRACT. SUBCONTRACTORS SHALL SUBMIT REQUESTS FOR AUTHORIZATION
TO RELEASE THROUGH THE PRIME CONTRACTOR TO THE CONTRACTING OFFICER.
1 REMOVE EXISTING TELECOMMUNICATIONS EQUIPMENT, SALVAGE
EXISTING HORIZONTAL CABLES. RECONNECT EXISTING HORIZONTAL
CABLES TO NEW WALL MOUNTED CABINET.
NOTES THIS SHEET
1/8" = 1'-0"
5'0'5' 10' 20'
NCONSTRUCTION FIRST FLOOR PLANSCALE: 1/8" = 1'-0"
ENLARGED PLAN - TELECOM ROOMSCALE: 1/4" = 1'-0" T-101
1
1/4" = 1'-0"
5' 10'0' 5'
02/24/20