Mini CONVENTIONAL FIRE ALARM SYSTEM EXPERT IN FIRE ALARM & SAFETY TECHNOLOGY CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE End of Line Resistor Smoke Detector Heat Detector Smoke & Heat Detector No.1 Slave Panel Smoke Detector Heat Detector Manual Call Point Smoke Detector Manual Call Point Smoke Detector Heat Detector Bell Bell Sound Strobe Sound Strobe Sound Strobe DC24V Power RS485 Communication DC24+ DC24- A B ZONE+ ZONE- ZONE+ ZONE- ZONE 1 ZONE 2 SOUND OUTPUT 4.7K 4.7K End of Line Resistor 1N4007 Diode End of Line Diode SOUND+ SOUND- Remote LED Remote LED Remote LED Remote LED Remote LED Max. 25 detectors in One Zone Max. 5 to 10 (1A@24VDC) Sounder & Bell in One Sound Output AC Power Input(90-270V) HOT NEUTRAL GROUND ZONE 1 ZONE 2 SOUND OUTPUT ZONE 1 ZONE 2 SOUND OUTPUT Max No.31 Slave Panel Master Panel DC24V DC24V Power Supply DC12V battery DC12V battery Fire1 Alarm Relay Output NO COM Fire2 Alarm Relay Output Fault Relay Output NO COM NO COM Fire1 Alarm Relay Output NO COM Fire2 Alarm Relay Output Fault Relay Output NO COM NO COM Fire1 Alarm Relay Output NO COM Fire2 Alarm Relay Output Fault Relay Output NO COM NO COM DC24+ DC24- A B RS485 Communication DC24V Power

CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE Mini CONVENTIONAL FIRE ALARM SYSTEM · 2013-08-08 · mini conventional fire alarm system expert in fire alarm & safety technology conventional

  • Upload
    lenga

  • View
    247

  • Download
    0

Embed Size (px)

Citation preview

Page 1: CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE Mini CONVENTIONAL FIRE ALARM SYSTEM · 2013-08-08 · mini conventional fire alarm system expert in fire alarm & safety technology conventional

Mini CONVENTIONAL

FIRE ALARM SYSTEM

EXPERT IN FIRE ALARM

& SAFETY TECHNOLOGY

CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE

End of Line Resistor

SmokeDetector

HeatDetector

Smoke & HeatDetector

No.1 Slave Panel

SmokeDetector

HeatDetector

ManualCall Point

SmokeDetector

ManualCall Point

SmokeDetector

HeatDetector

Bell Bell Sound StrobeSoundStrobe

SoundStrobe

DC24V Power

RS485 Communication

DC24+

DC24-

AB

ZONE+

ZONE-

ZONE+

ZONE-

ZO

NE

1

ZO

NE

2

SO

UN

D O

UT

PU

T

4.7K

4.7K

End of Line Resistor

1N40

07D

iode

End of Line Diode

SOUND+

SOUND-

Remote LED Remote LED Remote LED Remote LED Remote LED

Max. 25 detectorsin One Zone

Max. 5 to 10 (1A@24VDC) Sounder & Bell

in One Sound Output

AC Power Input(90-270V)

HOT

NEUTRAL

GROUND

ZO

NE

1

ZO

NE

2

SO

UN

D O

UT

PU

T

ZO

NE

1

ZO

NE

2

SO

UN

D O

UT

PU

T

Max No.31 Slave Panel Master Panel

DC

24V

DC24V Power Supply

DC12Vbattery

DC12Vbattery

Fire

1 A

larm

Rel

ay O

utpu

tN

O

CO

M

Fire

2 A

larm

Rel

ay O

utpu

t

Fau

lt R

elay

Out

put

NO

CO

M

NO

CO

M

Fire

1 A

larm

Rel

ay O

utpu

tN

O

CO

M

Fire

2 A

larm

Rel

ay O

utpu

t

Fau

lt R

elay

Out

put

NO

CO

M

NO

CO

M

Fire

1 A

larm

Rel

ay O

utpu

tN

O

CO

M

Fire

2 A

larm

Rel

ay O

utpu

t

Fau

lt R

elay

Out

put

NO

CO

M

NO

CO

M

DC24+

DC24-

ABRS485 Communication

DC24V Power

Page 2: CONVENTIONAL FIRE ALARM SYSTEM ARCHITECTURE Mini CONVENTIONAL FIRE ALARM SYSTEM · 2013-08-08 · mini conventional fire alarm system expert in fire alarm & safety technology conventional

Mini CONVENTIONAL FIRE ALARM CONTROL PANELS

FEATURES

CABINET AND MOUNTING

Fire Alarm Panel Cabinet physical dimensions: 108 mm wide x 143 mm high x 40 mm deep.

Power Supply Cabinet dimensions:: 205 mm high x 255 mm wide x 90 mm deep.

Master Panel Cabinet net weight: 520 g.

Slave Panel Cabinet net weight: 500g.

Mounting: The cabinet mounts using two key slots at the top of the back and two additional

6.5mm diameter holes at the bottom.

CP1002M 2 Zone Master

Fire Alarm Control Panel

CP1002S 2 Zone Slave

Fire Alarm Control Panel

Model: YT102

System Voltage: 24VDC

Standby Current: 200μA max.

Alarm Current: 50mA max.

WT105

FT103

CF6002

JL188

YT142

Smoke Detector

Model:

System Voltage: 24VDC

Standby Current: 200μA max.

Alarm Current: 50mA max.

Heat Detector

Model:

System Voltage: 24VDC

Standby Current: 200μA max.

Alarm Current: 50mA max.

Smoke & Heat Detector

Model:

System Voltage: 24VDC

Standby Current: 200μA max.

Alarm Current: 50mA max.

4-Wire Smoke Detector(Relay Output)

Model: SB106

System Voltage: 24VDC

Standby Current: 50μA max.

Alarm Current: 30mA max.

Manual Call Point

Model: SG109

System Voltage: 24VDC

Sound Output: 93dB(A)

Alarm Current: 30mA max.

Sounder Strobe

Model:

System Voltage: 24VDC

Spectrum: 180-290nm

Alarm Current: 20mA max.

Strobe

Model:

System Voltage: 24VDC

Sound Output: 95dB(A)

Alarm Current: 70mA max.

Bell

Relay Contact: 2A@24V

Diameter: 150mm

One slave Panel has two zones, each zone can connect max.25 conventional detectors.

One Master Panel also has two zones, each zone can connect max.25 conventional detectors.

The Mater panel could show the fire and fault of all slave panel. The slave panel can only

show itself fire and fault.

Mini size as 108X143X40mm

Master panel has 4 digital LED display to show slave number and status.

2 Detection Zones Panel, 25 Detectors per Zone

Fire 1 relay would be activated when one zone alarms.

Fire 2 relay would be activated after 30 seconds delay when two zones alarm.

1 Sound relay output for sound alarm

1 Fault relay output for fault condition

Zones Fire and Fault LEDs indication

Fire1, Fire2, Sound relay outputs can be activated manually

RS485 Port for repeater up to 1.2Km

Up to 31 Slave panels can be connected to one Master panel

Powered by outside DC22-26V power supply

End Of Line Status Detection, Short circuit /open circuit detection

Two modules power supply could be selected.

The power supply input is AC90-270V

Two 4AH batteries can be housed in the power supply cabinet.

Relay output contacts rated at: 2.0 amps @ 30 VDC.

CP35W:24V/1.5ACP70W: 24V/3.0A

Power Supply

The mini 2 zone panel have Master panel and Slave panel. One Master panel can connect 31 Slave panel, and the Master panel could show the fire and fault of all slave panel. The slave panel can only show itself fire and fault.

Mini CONVENTIONAL FIRE ALARM CONTROL PANELS