Upload
juan-jose-barreto
View
215
Download
2
Embed Size (px)
DESCRIPTION
Ortopedia y traumatologia
Citation preview
A complete occipito-cervico-thoracic fixation solution
Occipito-cervical and upper cervical spine instabilities:– Rheumatoid arthritis– Congenital anomalies– Posttraumatic conditions– Tumors– Infections
Instabilities in the lower cervical and upper thoracic spine:– Posttraumatic conditions– Tumors– Iatrogenic instabilities following laminectomy etc.
Degenerative and painful posttraumatic conditions in the lower cervical and upper thoracic spine
Anterior cervical fusions requiring additional posterior stabilization
Technique GuidesSynapse System: Occipito-Cervical Fusion System:036.000.755 036.000.981
Up to 50° screwangulation
Complete OCT solution
Best in class instruments
Synthes Solutions forPosterior Cervical Fixation.Synapse and Occipito-CervicalFusion System.
Indications
036.
000.
667
SE_2
0598
9 A
A
5008
0060
©
02/
2009
Syn
thes
, Inc
. or
its a
ffili
ates
A
ll rig
hts
rese
rved
Sy
nthe
s is
a t
rade
mar
k of
Syn
thes
, Inc
. or
its a
ffili
ates
Posterior cervical fixationSynapse is a top-loading implant system to stabilize the posteriorcervical spine. It consists of top-loading screws and hooks,transconnectors and � 3.5 mm rods. Synapse is compatible withthe Occipito-Cervical Fusion System which consists of occipitalplates, clamps and pre-bent rods.
Occipital fixationThe � 3.5 mm rod connects the screws in the cervical spine withthe plate in the occiput to achieve a stable occipito-cervical fixation.
Transition to thoracic spineOpen parallel connectors or tapered rods can be used to connectthe � 3.5 mm rod with any 5.0 mm or 6.0 mm rod and thus extendthe construct to the thoracic spine.
X-ray of Synapseand Occipito-Cervical FusionSystem
Ö036.000.667öAAoä
50°
8 mm
50°
50° 50°
� 3.5 mm � 4.0 mm
50° 50°
� 4.5 mm
40° 40° 40° 40°
� 3.5 mm shaft screw
Occipito-Cervical Fusion System.Implants and instruments designed tooptimize fixation to the occiput.
Synapse System. An enhanced set of instruments and implants for posteriorstabilization of the cervical and upperthoracic spine.
Polyaxial screws with up to 50° angulation in all directions– Enable advanced surgical techniques:
– Pedicle screw setting – C1/C2 fixation using Magerl Technique
– Simplify operation– Self-tapping for rapid insertion
Complete implant portfolio to accommodatepatient anatomy– Square threaded locking screw reduces
risk of cross-threading– Screws in three diameters– Shaft screws– Top-loading hooks– Transconnectors
Pre-bent rods– Pre-bent with 110° angulation– Stress-released to maintain strength
Occipital screws– � 4.5 mm screws and 5.0 mm rescue screw
Best in class instruments– Non-sticking and non-toggling screwdriver
Flexible instruments – Tap and screwdriver with cardan-joint for ease of use
Versatile possibilities for occipital fixation