Field Bus
Fieldbus
The generic term for industrial serial communication systems
Why use Fieldbus
Central control Reduce wiring Simple cable routing
Cost reduction Central diagnostics
and monitoring
Where to use Fieldbus
Systems with widely spaced I/O
Plant with many machines
Applications include: Automotive assembly Paper making Printing Airport goods handling Chemical processing Food and drink packaging Energy production Security systems Water treatment Traffic control
System layout
Machine with widely spaced I/O Plant with many machines
Click the illustration to start and stop animation
Input and output devices
Switches and sensors wire to remote input modules
Output devices wire to remote output modules
Bus specific devices wire direct to the bus
Fieldbus VE2
Modular system Expand to 128 I/O total
from a single node interface
Modules close coupled, distributed up to 500m or mixed
Protection to IP 65 Easy protocol change State of art diagnostics
Fieldbus VE2
Fieldbus interface module
Interchangeable protocol
PROFIBUS DP, InterBus-S, Device-Net
CanOpen soon
Fieldbus VE2
I/O modules: inputs for reed
switches and sensors outputs for external
valves and relays 8 inputs or outputs or 4
of each per module
Valve island V20 / V22
Full range of 5/2 and 5/3 valves
Integrated rigid base and wireway
Proven sealing technology
Double solenoids single width single end
Low power 1.5 W 24V dc
Close coupled modules
Central PLC control For remote positions
with concentrated action
Each interface station assembled with I/O and valves required
Click the illustration to start and stop animation
Distributed modules
Central PLC control Remote interface, I/O
and valve islands
Communication distance up to 500m
Click the illustration to start and stop animation
AS-Interface (Actuator Sensor Interface)
AS-I (Actuator Sensor Interface)
Open system Low cost installation Stand alone system Sub-system from gateway High immunity to noise
and interference Simple node attachment Protection to IP65
Tree Topology Total cable length 100m 32 Nodes per system I/O 124 maximum
Input output Modules
4 Way modules2 inputs, 2 outputs or4 inputs or4 outputs
8 Way modules4 inputs and 4 outputs
Bus cable (yellow) parallel pair no screen plus power for inputs
Power cable (black) for outputs
Input output Modules
Quick connection Pins pierce the
insulation displacement cable (IDC) as the node is clipped on
Protection to IP65
Click the illustration to start and stop animation
AS-I Valve islands
Configurations 2 Valves / 2 Inputs 4 Valves 4 Valves / 4 Inputs 8 Valves
AS-I System
Controller generating communication signals on yellow cable
Power supply modules Outputs module 4 Inputs module 4 Module 2 inputs / 2
outputs AS-I Valve Island
Gateways
Complex systems may link Fieldbus types
A gateway converts one protocol to another
A gateway / controller for fast local system with communication to a higher Fieldbus
PROFIBUS DP
AS-I AS-I
PLC
AS-I Controllers
Gateway controllers can function in three ways
A stand alone AS-I controller
Active gateway controlling the local AS-I system
A passive gateway acting only as a translator
DeviceNet
PROFIBUS DP
Integrated PLC
Stand alone or bus master
Integrated PLC
Combined PLC, I/O interface and valve island
Choice of valve islands Nugget 30, 40, 120 and MIDI*STAR
Stand alone system controller, or
Fieldbus master to control up to 62 slaves
Easy programming using descriptive text statements
End