A complete solution for mechanical complications encountered in implantology CASE N°1 REMOVAL OF BLOCKED ABUTMENTS IN THE IMPLANT An abutment extractor may be used to remove abutments without affecting the implant. CASE N°2 EXTRACTION OF A SCREW FOLLOWING HEXAGON DEFORMATION The hexagon of the attachment screw, cover screw or healing abutment has become deformed on tightening. Using a screw extractor, you can now safely unscrew your prosthetic components. CASE N°4 REMOVAL OF AN IMPLANT An implant extractor makes it possible to hook onto and unscrew the implant. Trepanation may be carried out on the bone around the implant using osseo treph- ines adapted to the different diameters of the implant. CASE N°3 REMOVAL OF A BROKEN SCREW IN THE IMPLANT Using a drilling guide, a reverse drill bit is guided to hook onto and unscrew the screw fragment. A tap drill can be used to adjust the tapping of the implant if it is damaged. EXTRACTION KIT Non contractual illustrations.

EXTRACTION KIT - DonutsEXTRACTION KIT REFERENCE KDR_3N KDR_AEST M1.6 abutment extractor Naturactis, Naturall+, Natea+ Naturall Ø 3.5, Natea Ø 3.6 X CEP_16.175 M2 abutment extractor

  • Upload
    others

  • View
    6

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EXTRACTION KIT - DonutsEXTRACTION KIT REFERENCE KDR_3N KDR_AEST M1.6 abutment extractor Naturactis, Naturall+, Natea+ Naturall Ø 3.5, Natea Ø 3.6 X CEP_16.175 M2 abutment extractor

A complete solution formechanical complicationsencountered in implantology

CASE N°1REMOVAL OF BLOCKED ABUTMENTSIN THE IMPLANTAn abutment extractor may be used to remove abutments without affecting the implant.

CASE N°2EXTRACTION OF A SCREW FOLLOWING

HEXAGON DEFORMATION The hexagon of the attachment screw, cover screw

or healing abutment has become deformed on tightening. Using a screw extractor, you can now

safely unscrew your prosthetic components.

CASE N°4REMOVAL OF AN IMPLANT

An implant extractor makes it possible to hook ontoand unscrew the implant. Trepanation may be carried

out on the bone around the implant using osseo treph- ines adapted to the different diameters of the implant.

CASE N°3REMOVAL OF A BROKEN SCREW IN THEIMPLANTUsing a drilling guide, a reverse drill bit is guided to hook onto and unscrew the screw fragment.A tap drill can be used to adjust the tapping of theimplant if it is damaged.

EXTRACTION KIT

Non contractual illustrations.

Page 2: EXTRACTION KIT - DonutsEXTRACTION KIT REFERENCE KDR_3N KDR_AEST M1.6 abutment extractor Naturactis, Naturall+, Natea+ Naturall Ø 3.5, Natea Ø 3.6 X CEP_16.175 M2 abutment extractor

DESCRIPTION ILLUSTRATION IMPLANT RANGEEXTRACTION KIT

REFERENCEKDR_3N KDR_AEST

M1.6 abutment extractor Naturactis, Naturall+, Natea+Naturall Ø 3.5, Natea Ø 3.6

X CEP_16.175

M2 abutment extractor

Aesthetica+2 / Aesthetica+Uneva / Uneva+

Naturall Ø 4 - Ø 4.5 - Ø 5Natea Ø 4.1 - Ø 4.8 - Ø 6

X CEP_20.175

Trephine Ø 3.2 Naturactis Ø 3, Naturall+ Ø 3Naturex

X CMK_TR32

Trephine Ø 3.8 All implants X X CMK_TR38

Trephine Ø 4.6 All implants X X CMK_TR46

Trephine Ø 5.3 All implants X X CMK_TR53

Trephine Ø 6.7 All implants X X CMK_TR67

M1.4 tap drill Naturactis Ø 3, Naturall+ Ø 3Naturex

X CTK_TA14

M1.6 tap drill Naturactis, Naturall+, Natea+Naturall Ø 3.5, Natea Ø 3.6

X CTK_TA16

M2 tap drill

Aesthetica+2 / Aesthetica+Uneva / Uneva+

Naturall Ø 4 - Ø 4.5 - Ø 5Natea Ø 4.1 - Ø 4.8 - Ø 6

X CTK_TA20

Screw extractor All implants X X CCK_QV15.150

Removal of an implant All implants X X CCK_QI15.150

Reverse drill Ø 1.2 All implants (except Naturactis Ø 3,

Naturall+ Ø 3)

X X CFK_TG12

Short reverse drill Ø 1.2 X X CFK_TG12S

Reverse drill Ø 1.2 Naturactis Ø 3, Naturall+ Ø 3 X CFK_TG123

Drilling guide Naturactis, Naturall+, Natea+Naturall Ø 3.5, Natea Ø 3.6

X CGK_3N

Short drilling guide Naturactis, Naturall+, Natea+Naturall Ø 3.5, Natea Ø 3.6

X CGK_3NS

Drilling guide Naturactis Ø 3, Naturall+ Ø 3 X CGK_3

Drilling guide Naturall Ø 4 - Ø 4.5 - Ø 5Natea Ø 4.1 - Ø 4.8 - Ø 6

X CGK_N.RPWP

Drilling guide Naturex CGK_NAT

Drilling guide Aesthetica+ / Aesthetica+2 X CGK_AEST

Drilling guide Uneva / Uneva+ X CGK_U

KITS REFERENCES IMPLANT RANGES

KDR_3N Natea+ / Naturactis / Naturall+ / Naturactis Ø 3 / Naturall+ Ø 3 / Naturall Ø 3.5 / Natea Ø 3.6

KDR_AEST Aesthetica+2 / Aesthetica+ / Natea Ø 4.1 - Ø 4.8 - Ø 6 / Naturall Ø 4 - Ø 4.5 - Ø 5 / Uneva+ Ø 4.1 - 4.8 - Ø 6

EXTRACTION KITS - REFERENCES

EXTRACTION KIT SPARE PARTS - REFERENCES

euroteknika - 726 rue du Général De Gaulle - 74700 Sallanches - FranceT : +33 (0)4 50 91 49 20 - F : +33 (0)4 50 91 98 66 - [email protected] - www.etk.dentaleuroteknika implants are medical devices of Class IIb (European Directive 93/42/CEE) comply with the standards of conformity and CE0459 marking carrier. Read carefully the instructions for use and user manual.Ref_Kit_extraction_GB_i0_201803_web

Note: There is no extraction kit for the Naturex implant but it is possible to find all the necessary extraction parts in the table above.