YOUR PARTNER FOR SAFETY
Since 1961
Explosion Proof Electrical Equipment
tfii
tfii
Feam Catalogue 03 - 1
Ex Conduit fittings
EXPLOSiON PROOf StAiNLESS StEEL fLEXiBLE CONDUit
ON REqUESt ACCESSORiES: •Differentlengthsfromstandard•PVCcoating•Femalethreadendterminal•Maleorfemalethreadrevolvingendterninal
Mechanical characteristics
APPLiCAtiONS
Internalflexiblepipe stainlesssteel
Externalbraid stainlesssteel
Terminals threadedterminalsinstainlesssteelorcoldgalvanizedsteel
•FLEXIBLECONDUITSAREINSTALLEDWHERECONNECTIONSMUSTBEMADETOEQUIPMENTSUBJECTTOVIBRATIONS:MOTORS,PUMPS,ETC.
•ALSOFAVOUREDFORCONNECTIONTOPEDANTLIGHTINGFITTINGANDATBENDSWHERERIGIDCONDUITSISDIFFICULTTOHANDLE.
Installation: hazardousareas-Zone1/2(Gases)-Zone21/22(Dusts) Classification: GroupII-Category2G2D
fLEXiBLE CONDUit PiPE
AtEX 94/9/EC iEC Ex iNMEtRO GOSt-R (RtR/RtN) GOSt-K
EXECUtiONII2GExdIIBII2GExdIICII2DExtDA21
ExdIIBGbExdIICGbExtbIIICDb
ExdIIBGbExdIICGbExtbIIICDb
ExdIIBUExdIICUExtDA21
ExdIIBUExdIICUExtDA21
AMBiENttEMPERAtURE -50°C÷+130°C -50°C÷+130°C -50°C÷+130°C -60°C÷+130°C -60°C÷+130°C
PROtEC. DEGREE IP66/67 IP66/67 IP66/67 IP66/67 IP66/67
CERtifiCAtE REf. INERIS07ATEX9001U IECExINE12.0043U CEPEL13.2241U POCCIT.ME92.B02924 No.07/43-269
RULES Of COMPLiANCE
EN60079-0;EN60079-1;EN61241-0;EN61241-1
IEC60079-0:2011;IEC60079-1:2007;IEC60079-31:2008
ABNTNBRIEC60079-0:2008;ABNTNBRIEC60079-1:2007;ABNTNBRIEC60079-7:2008;ABNTNBRIEC60529-0:2009
ГОСТРМЭК60079-0:2011;ГОСТРМЭК61241-0:2007;ГОСТРМЭК61241-1:2004
ГОСТР51330.0/1/8/14-99ГОСТРМЭК61241-1-1-2002
AtEX / iECEx / GOStNEC 505 NEC 500Class I Class I Class II Class III
Zone 0 1 2 20 21 22 Zone 0 1 2 Division 1 2 1 2 1 2X X X X X X X X X X X X
YOUR PARTNER FOR SAFETY
Since 1961
tfii
300 X X - - - - - -
400 X X X X X X X X
450 X X X X X X X X
500 X X X X X X X X
600 X X X X X X X X
700 X X X X X X X X
800 X X X X X X X X
900 X X X X X X X X
1000 X X X X X X X X
ØBØ
A
C
TFII# 0500 02 IN
TFII# 1000 06 AC
tfii
2 - Feam Catalogue 03
ExConduitfittings
TFII - Technical Features
Reference Details
StANDARD LENGHtS [mm]fLEXiBLE CONDUit SiZE
1 2 3 4 5 6 7 8
TFII Standard lenghts
*fLEX. CONDUit PiPES WitH LENGHS DiffERENt tHAN StANDARD, PLEASE CONtACt OUR SALES DEPt.
TERMINAL TERMINAL
REMARK: Duetothedevelopmentofthenationalandinternationalspecificationsandofthetechnology,theabovetechnicalcharacteristicsshowedonthisbulletincanbeconsideredasbindingonourconfirmationonly.
SiZE tHREAD* iNtERNAL DiA. [ØA] [mm]
EXtERNAL DiA. [ØB] [mm]
C - LENGHt [mm] tERMiNAL’S MAtERiAL
01 (1/2") 12 18 300 IN(stainlesssteel)-AC(galvanizedsteel)
02 (3/4) 16 24 300 IN(stainlesssteel)-AC(galvanizedsteel)
03 (1") 25 35 400 IN(stainlesssteel)-AC(galvanizedsteel)
04 (1-1/4") 32 42 400 IN(stainlesssteel)-AC(galvanizedsteel)
05 (1-1/2") 40 52 400 IN(stainlesssteel)-AC(galvanizedsteel)
06 (2") 50 66 400 IN(stainlesssteel)-AC(galvanizedsteel)
07 (2-1/2") 65 82 400 IN(stainlesssteel)-AC(galvanizedsteel)
08 (3") 80 100 400 IN(stainlesssteel)-AC(galvanizedsteel)
010 (4") 100 122 400 IN(stainlesssteel)-AC(galvanizedsteel)
C - LENGHt [mm] SiZE tERMiNAL’S MAtERiAL
*REMARK: pleaseadd “N” sentenceaftercode“TFII” toidentifytheterminalendsthreadNPT(ASAB2.1).Theonlycode“TFII” identifiesUNI-6125terminalendsthread
EXAMPLE 1:TFIIN#50002IN=FlexibleConduit3/4”Dia.500mmtotallenghtc/wstainlesssteelNPTthreadfixedmaleterminalends.EXAMPLE 2: TFIIN#100006IN=FlexibleConduit2”Dia.1000mmtotallenghtc/wgalvanizedsteelUNI-6125threadfixedmaleterminalends.