Your first and safest choice for explosion proof indicators. Datasheet E110 - 1 -
Datasheet E110Robust explosion proof indicator
Advantages Save time and win flexibility with the easy-to-operate through glass
keypad: no need to remove the front cover nor to arrange a work permit.
Your crew is in control with our highly praised “know one, know them all”
configuration structure, saving time, cost and aggravation.
Easy installation with the spacious chamber and plug and play connectors.
Cost saving with an easy to install, 1” NPT thread for flow meter mounting.
Long life duration in extremely salty atmospheres (offshore) with heavy
duty stainless steel Exd enclosure.
Key information at a glance as the display shows flow rate, total,
measuring units and a flow rate indicating speedometer.
Features Selectable on-screen engineering units; volumetric or mass.
7 digit flow rate / total and 11 digit accumulated total.
Power options: Loop powered, battery and 8 - 30V DC.
Sensor supply 8.2 / 12 / 24V DC.
Modbus communication option RS232 / RS485.
Data logging to survey information (pending).
Outputs Isolated, loop powered 4 - 20mA output according to flow rate.
Scaled pulse output according to accumulated total.
Inputs Ability to process all types of volumetric or mass flowmeter signals:
Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), Active pulse
signals. (0)4 - 20mA and 0 - 10V DC analog inputs are pending.
Applications Liquid flow measurement where re-transmission of the flow rate and/or
totalizer functions or serial communication is required.
The E110 offers you an enclosure designed to be used in rough and tough
applications, beyond being just explosion proof. Its sturdy design and
ease of use are unequaled by any other explosion proof indicator in the
market! The E-Series is always your first and safest choice in explosion
proof applications.
For intrinsically safe applications we offer our field mount F-Series
indicators.
Flow rate Indicator / Totalizerwith analog and pulse signal outputs
Reliable
Your first and safest choice for explosion proof indicators. Datasheet E110 - 2 -
General informationIntroductionThe E110 is a popular model in our range of explosion proof flow rate indicators. The E-series distinguishes itself by its quality and functionality driven European design and manufacturing. In our opinion, it is not just about fulfilling the rules for explosion proof design, as often offered by Asian manufactured enclosures, but it is about safety during the daily operational practice. Often, the environment is much tougher than the explosion proof requirements ask for. Immediate danger arises in case of a broken enclosure or a poorly made flame path. Ruggedness and reliability is where Fluidwell stands for and it is now available in a comprehensive well designed and purpose driven Explosion proof enclosure.
DisplayThe unique LCD display provides multiple flow data in a glance. The main information is displayed with 7 digits (12mm, 0.47”) to show total or flow rate and 11 segments (7mm, 0.28”), which can be set to show flow rate and accumulated total. On-screen engineering units are easily configured from a comprehensive selection, while different units for flow rate and total can be displayed simultaneously. The speedometer offers a quick impression of the actual flow rate. All values are saved in EEPROM memory. For good readings in full sunlight and darkness, the E110 is provided with a bright backlight. When battery powered the backlight is only operational during setup to extend battery lifetime.
ConfigurationThe E-Series uses the highly appreciated configuration structure of our F- and D-Series product line. Each setting is clearly indicated with an alphanumerical description, which avoids confusing abbreviations. Once familiar with one E-series product, you will be able to program all models in all series without a manual. For example: an (intrinsically safe) F110 operates identical to an explosion proof E110 and has the same three buttons! In other words: know one, know them all. Operation and configuration is done via the easy-to-operate keypad, through glass button programming without having to remove the front cover. All settings are accessed via a simple operator menu that can be passcode protected.
Flow meter inputThe E110 accepts most input signals for volume flow or mass flow meters. The input signal type can be selected in the configuration menu without having to adjust any sensitive mechanical dip-switches or jumpers.
Robust stainless Steel 316L enclosure
Highly accurate threads (6g/6H-iso965-1 & 965-3)
Very robust side entry thread (T1)
Very robust bottom entry thread (T2)
Your first and safest choice for explosion proof indicators. Datasheet E110 - 3 -
Analog outputThe flow rate is transmitted with the galvanically isolated 4 - 20mA output signal. The E110 can even be powered via the isolated loop-current. Fault detection according Namur NE43 for fast error solving is pending.
Pulse outputsScaled pulse output is according the accumulated total. The pulse length is user defined from 1msec up to 10 seconds. The maximum output frequency is 500Hz. The output is a passive NPN signal.
CommunicationAll processed data and settings can be read and modified through the Modbus link (RS232 / RS485).
Power requirementsSeveral power inputs are available to power the E110 and sensor. The battery powered version with a long life lithium battery and the basic 8 - 30V DC do power the E110 including the backlight, but don’t offer a real sensor supply. A real sensor supply of 8.2, 12 or 24V is offered with the 16 - 30V DC power option.
Hazardous areasThe enclosure of the E110 has been certified according ATEX and IECEx by DEKRA with an ambient temperature of -40°C to +70°C (-40°F to +158°F). CSA and FM are pending and expected to be available soon.The application range of the enclosure is very wide:
The ATEX markings are:Gas: II 2 G Ex d IIC T6 GbDust: II 2 D Ex tb IIIC T85°C Db
The IECEx markings are:Gas: Ex d IIC T6 Gb Dust: Ex tb IIIC T85°C Db
The CSA / FM certification is pending according: Explosion-proof for use in Class I, Division 1, Groups A, B, C, D. DIP (Dust-Ignition-proof): Class II, Division 1, Groups E, F, and G. Class III; hazardous (classified) locations.
EnclosuresTwo fundamental versions of our IP67, NEMA 4X/7/8/9 explosion proof enclosures are available: a solid die cast aluminum or a heavy duty stainless steel 316L enclosure resistant to extremely salty atmospheres (offshore). The aluminum enclosure has an industrial two component coating and is better suitable for outdoor and chemical plant applications than powder coated alternatives. A major advantage for the installation engineer is the easy installation due to the spacious mid-chamber for the cable entry in combination with the plug-and-play connectors. Various connections threads are available, NPT and metric. Especially for use on top of Turbine meters is a 1” NPT connection available for straight flow meter mounting (see page 4 for the various threads available).
Very easy-to-operate through glass keypad
Overview application E110
Analogoutput
ModbusCommunication
Flowmeterinput
Pulseoutput
PROG
ENTER
SELECT CLEAR
E-Series
Reset Total
Your first and safest choice for explosion proof indicators. Datasheet E110 - 4 -
Dimensions enclosures Terminal connections
Display example - 1:1
P2P3
POW
ER S
UPP
LY
P1
PX: 8
- 30
V D
C
PD: 1
6 - 3
0V D
C
R1
R2
R4
R5
PULS
E /
ALA
RM
OU
TPU
TS
R3
PB: b
atte
ry p
ower
ed(P
X is
als
o av
aila
ble:
if a
n ex
tern
al s
uppl
y is
con
nect
ed,
the
batt
ery
supp
ly w
ill b
e sw
itch
ed o
ff /
on
auto
mat
ical
ly.)
++
OT:
pas
sive
tran
sist
or o
utpu
t
+
R6
S5S6
S4E1
E2P4
EXTE
RN
AL
INPU
T &
SEN
SOR
SU
PPLY
E3S2
S3
SEN
SOR
INPU
T 1
S1
Sens
or s
uppl
y: 8
.2 /
12
/ 24
VP:
reed
sw
itch
/ N
PN
P: c
oil
P: n
amur
P: P
NP
A: (0
)4 -
20m
A is
pen
ding
P: a
ctiv
e si
gnal
U: 0
- 10
V is
pen
ding
-+ - + +I +U
+3V +3V +3V +3V +3V
+8.
2 /
12
/ 24
V
Rese
t tot
al
Not
e: T
he s
enso
r sup
ply
(P4)
is
onl
y av
aila
ble
wit
h PD
.
C1C2
C4
MO
DB
US
CO
MM
UN
ICAT
ION
C3
AN
ALO
G O
UTP
UT
A1A2
AH: I
sola
ted
4 - 2
0mA
I- / +I- / +
CB: R
S232
CH: R
S485
- 2
wir
e AB
RXD
TXD
DTR
+12V
Not
e: P
olar
ity
in
sens
itiv
e.
+
PROG
ENTER
SELECT CLEAR
E-Series
112 (4.41”)
133
(5.2
4”)
148 (5.83”)
Entry thread T2
2 x Entry thread T1
Entry threads enclosureType HA Aluminum, T1: 2 x 3/4”NPT / T2: 1”NPT
Type HB Aluminum, T1: 2 x 3/4”NPT / T2: 3/4”NPT
Type HC Aluminum, T1: 2 x 1/2”NPT / T2: 1”NPT
Type HD Aluminum, T1: 2 x 1/2”NPT / T2: 3/4”NPT
Type HG Aluminum, T1: 2 x M20 / T2: M25
Type HH Aluminum, T1: 2 x M25 / T2: M25
Type HN Stainless Steel 316L, T1: 2 x 3/4”NPT / T2: 1”NPT
Type HO Stainless Steel 316L, T1: 2 x 3/4”NPT / T2: 3/4”NPT
Type HP Stainless Steel 316L, T1: 2 x 1/2”NPT / T2: 1”NPT
Type HR Stainless Steel 316L, T1: 2 x 1/2”NPT / T2: 3/4”NPT
Type HU Stainless Steel 316L, T1: 2 x M20 / T2: M25
Type HV Stainless Steel 316L, T1: 2 x M25 / T2: M25
Your first and safest choice for explosion proof indicators. Datasheet E110 - 5 -
Typical wiring diagram E110-P-AH-CB-OT-PD Typical wiring diagram E110-P-AH-CH-OT-PX
P1P2
P3S4
S5S6
R4
R3
R5
R6
Common ground
TERMINAL CONNECTORSE-series
Typical wiring diagram E110-P-AH-CB-OT-PD
16 - 30V DC
+
-
Supply *
Common ground
Main supply
C3C2
C1C4
Common ground
*Supply voltage S3: 3V DC and supply voltage P4: 8.2 / 12 / 24V DC to sensor
RXD
TXD
DTR12V
S1S2
S3
Common ground
Signal
Supply *
Earth
Modbus communication type CB: RS232
Power supply type PD: 16 - 30V DC
16 - 30V DC POWER SUPPLY
A1A2
R2
R1Common ground
output type OT:passive transistore.g. counter output
123456
P4E3
E2E1Common ground
Powersupply
10 - 30V DC
+
-
e.g. indicator
Analog output type AH: (loop powered)Galvanically isolated 4 - 20mA
P1P2
P3S4
S5S6
R4
R3
R5
R6
Common ground
TERMINAL CONNECTORSE-series
Common ground
Main supply
C3C2
C1C4
Common ground
*Supply voltage S3: 3V DC to sensor
S1S2
S3
Common ground
Signal
Supply *
OUTPUT LOOP POWERED
A1A2
R2
R1Common ground
e.g. counter output123456
P4E3
E2E1Common ground
Powersupply
10 - 30V DC
+
-
e.g. indicator
Analog output type AH: (loop powered)Galvanically isolated 4 - 20mA
Typical wiring diagram E110-P-AH-CH-OT-PX
A
B
Modbus communication type CH: RS485 - 2 wire
Flowmeter input type: Ppulse
Circ
uit d
epen
ds o
n ty
pe o
f sig
nal
Power supply type PX: 8 - 30V DC
(not used in this example)
+
-
Flowmeter input type: Ppulse
output type OT:passive transistor
Status input:Reset total
+ 3.2Vlow-pass
filter
1M
Status input:Reset total
+ 3.2Vlow-pass
filter
1M
P1P2
P3S4
S5S6
R4
R3
R5
R6
Common ground
TERMINAL CONNECTORSE-series
Typical wiring diagram E110-P-AH-CB-OT-PD
16 - 30V DC
+
-
Supply *
Common ground
Main supply
C3C2
C1C4
Common ground
*Supply voltage S3: 3V DC and supply voltage P4: 8.2 / 12 / 24V DC to sensor
RXD
TXD
DTR12V
S1S2
S3
Common ground
Signal
Supply *
Earth
Modbus communication type CB: RS232
Power supply type PD: 16 - 30V DC
16 - 30V DC POWER SUPPLY
A1A2
R2
R1Common ground
output type OT:passive transistore.g. counter output
123456
P4E3
E2E1Common ground
Powersupply
10 - 30V DC
+
-
e.g. indicator
Analog output type AH: (loop powered)Galvanically isolated 4 - 20mA
P1P2
P3S4
S5S6
R4
R3
R5
R6
Common ground
TERMINAL CONNECTORSE-series
Common ground
Main supply
C3C2
C1C4
Common ground
*Supply voltage S3: 3V DC to sensor
S1S2
S3
Common ground
Signal
Supply *
OUTPUT LOOP POWERED
A1A2
R2
R1Common ground
e.g. counter output123456
P4E3
E2E1Common ground
Powersupply
10 - 30V DC
+
-
e.g. indicator
Analog output type AH: (loop powered)Galvanically isolated 4 - 20mA
Typical wiring diagram E110-P-AH-CH-OT-PX
A
B
Modbus communication type CH: RS485 - 2 wire
Flowmeter input type: Ppulse
Circ
uit d
epen
ds o
n ty
pe o
f sig
nal
Power supply type PX: 8 - 30V DC
(not used in this example)
+
-
Flowmeter input type: Ppulse
output type OT:passive transistor
Status input:Reset total
+ 3.2Vlow-pass
filter
1M
Status input:Reset total
+ 3.2Vlow-pass
filter
1M
Your first and safest choice for explosion proof indicators. Datasheet E110 - 6 -
Hazardous areaExplosion proofATEX II 2 G Ex d IIC T6 Gb.
certification II 2 D Ex tb IIIC T85°C Db.
IECEx Ex d IIC T6 Gb.
certification Ex tb IIIC T85°C Db.
FM / CSA c-us Pending according:
certification Explosion-proof for use in Class I, Division 1,
Groups A, B, C, D.
DIP (Dust-Ignition-proof): Class II, Division 1, Groups
E, F, and G. Class III; hazardous (classified) locations.
Ambient Ta -40°C to +70°C (-40°F to +158°F).
Directives EMC Compliant ref: EN61326-1 and FCC 47 CFR part 15.
Low voltage Compliant ref: EN61010-1.
CasingGeneral Window Glass window.
Sealing Silicone.
Control keys Three infra-red keys with operation through the
glass front window.
Aluminum enclosureGeneral Die-cast aluminum EXd enclosure.
Rating IP67 / NEMA 4X / NEMA 7 / NEMA 8 / NEMA 9.
Dimensions 112 x 133 x 148mm (4.41” x 5.24” x 5.83”) - W x H x D.
Weight 1300 gr.
Type HA Entry threads: 2 x 3/4”NPT / 1 x 1”NPT
Type HB Entry threads: 3 x 3/4”NPT
Type HC Entry threads: 2 x 1/2”NPT / 1 x 1”NPT
Type HD Entry threads: 2 x 1/2”NPT / 1 x 3/4”NPT
Type HG Entry threads: 2 x M20 / 1 x M25
Type HH Entry threads: 3 x M25
Stainless steel enclosureGeneral Stainless steel EXd enclosure.
Rating IP67 / NEMA 4X / NEMA 7 / NEMA 8 / NEMA 9.
Dimensions 112 x 133 x 148mm (4.41” x 5.24” x 5.83”) - W x H x D.
Weight 3600 gr.
Type HN Entry threads: 2 x 3/4”NPT / 1 x 1”NPT
Type HO Entry threads: 3 x 3/4”NPT
Type HP Entry threads: 2 x 1/2”NPT / 1 x 1”NPT
Type HR Entry threads: 2 x 1/2”NPT / 1 x 3/4”NPT
Type HU Entry threads: 2 x M20 / 1 x M25
Type HV Entry threads: 3 x M25
Technical specificationGeneralDisplay Type High intensity transflective numeric and alpha-
numeric LCD, UV-resistant, with bright backlight.
Intensity can be adjusted via the keyboard.
Note When battery powered, the backlight is only
operational during setup to extend battery lifetime.
Dimensions 65 x 45mm (2.56” x 1.77”).
Digits Seven 12mm (0.47”) and eleven 7mm (0.28”) digits.
Various symbols and measuring units.
Refresh rate User definable: 8 times/sec. - 30 secs.
Speedometer The black indicators around the edge run from
0 to 100% in 20 blocks, each block is 5%.
Operating temperatureOperational -40°C to +70°C (-40°F to +158°F).
Power requirementsType PB Long life Lithium battery - life-time depends upon
settings and configuration - up to several years.
Note When battery powered, the backlight is only
operational during setup to extend battery lifetime.
Type PD 16 - 30V DC. Power consumption max. 4.2 Watt.
Type PX 8 - 30V DC. Power consumption max. 4.2 Watt.
Type AH Loop powered, analog output. 10 - 30V DC,
Minimal 3mA. Power consumption max. 25mWatt.
Note AH The loop powered analog output cannot power the
backlight, mechanical relay output (OR) or the real
sensor supply (Terminal S10).
Sensor excitationType AH/PB/PX Terminal S3: 3V DC for pulse signals
and 1.2V DC for coil pick-up.
Note This is not a real sensor supply. Only suitable for
sensors with a very low power consumption like coils
(sine wave) and reed-switches.
Type PD Terminal P4: 8.2 / 12 / 24V DC
8.2V DC, Iout max. 20mA.
12V DC, Iout max. 30mA.
24V DC, Iout max. 75mA (this voltage varies
depending on the input supply voltage)
Terminal connectionsType Removable plug-in terminal strip.
Wire max. 1.5mm2 and 2.5mm2.
Data protection Type EEPROM backup of all settings. Backup of running
totals every minute. Data retention at least 10 years.
Pass-code Configuration settings can be pass-code protected.
Your first and safest choice for explosion proof indicators. Datasheet E110 - 7 -
Communication optionFunction Reading display information, reading / writing all
configuration settings.
Type CB Modbus RTU - RS232
Type CH Modbus RTU - RS485 2-wire
Speed 1200 - 2400 - 4800 - 9600 baud.
Addressing Maximum 255 addresses.
OperationalOperator functionsDisplayed • Flow rate and / or total.
functions • total and accumulated total.
• Indicating speedometer for flow rate.
• Total can be reset to zero by pressing the
CLEAR-key twice.
TotalDigits 7 digits.
Units L, m3, GAL, USGAL, kg, lb, bbl, ft3, Ton, igal, no unit.
Decimals 0 - 1 - 2 or 3.
Note Total can be reset to zero.
Accumulated totalDigits 11 digits.
Units / decimals According to selection for total.
Note Can not be reset to zero.
Flow rateDigits 7 digits.
Units mL, L, m3, Gallons, kg, Ton, lb, bl, cf, RND, ft3, scf,
Nm3, Nl, igal - no units.
Decimals 0 - 1 - 2 or 3.
Time units /sec - /min - /hr - /day.
Signal inputFlowmeter sensorType P Coil / sine wave (minimum 20mVpp or 80mVpp -
sensitivity selectable), NPN/PNP, open collector,
reedswitch,Namur, active pulse signals 8/12/24V DC.
Frequency Minimum 0Hz - maximum 7kHz for total and flow
rate. Maximum frequency depends on signal type
and internal low-pass filter. E.g. reed switch with
low-pass filter: max. frequency 120Hz.
K-Factor 0.000010 - 9,999,999 with variable decimal position.
Low-pass filter Available for all pulse signals.
Option ZF coil sensitivity 10mVpp.
Option ZG coil sensitivity 5mVpp.
Type A Pending: (0)4 - 20mA. Analog input signal can be
scaled to any desired range within 0 - 20mA.
Type U Pending: 0 - 10V DC. Analog input signal can be
scaled to any desired range within 0 - 10V DC.
Accuracy Resolution: 16 bit. Error < 0.01mA / ± 0.05% FS.
Low level cut-off programmable.
Span 0.001 / 999,999 with variable decimal position.
Update time Four times per second.
Voltage drop Type A: max. 1V DC @ 20mA.
Load impedance Type U: 3kOhm.
Relationship Linear and square root calculation.
Note For signal type A and U: external power to sensor is
required; e.g. type PD.
External inputFunction • Terminal input to reset total remotely.
• If this terminal input is closed, the “clear total”
function is disabled.
Type Internally pulled-up switch contact - NPN.
Duration Minimum pulse duration 100msec.
Signal outputsDigital outputFunction Pulse output: Transmitting accumulated total.
Frequency Max. 500Hz. Pulse length user definable between
1msec up to 10 seconds.
Type OT One passive transistor output (NPN) - not isolated.
300mA - 50V @ 25°C.
Analog outputType AH Galvanically isolated, loop powered 4 - 20mA output
Function Transmitting flow rate.
Accuracy 12 bit. Error < 0.1%. Analog output signal can be
scaled to any desired range.
Fault detection Pending: According to Namur NE43.
Datasheet E110Robust explosion proof indicator
Fluidwell bv
P.O. Box 6 • 5460 AA • Veghel
Voltaweg 23 • 5466 AZ • Veghel
The Netherlands
Telephone: +31 (0) 413 - 343 786
Telefax: +31 (0) 413 - 363 443
Email: [email protected]
Internet: www.fluidwell.com Specifications are subject to change without notice. Copyright: Fluidwell bv - 2014 - E110-DATA-EN-V1406
Ordering informationStandard configuration: E110-P-AH-CX-HA-OT-PX-XD-ZX.Ordering information: E110 -P -AH -C _ -H _ -OT -P _ -XD -Z _Flowmeter input signalA Pending: (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U Pending: 0 - 10V DC input.Analog output signalAH Galvanically isolated, loop powered 4-20mA output.CommunicationCB RS232 communication - Modbus RTU.CH RS485 communication - 2wire - Modbus RTU.CX No communication.Aluminum EXd enclosure, IP67 / NEMA4XHA Entry threads: 2 x 3/4”NPT / 1 x 1”NPT.HB Entry threads: 3 x 3/4”NPT.HC Entry threads: 2 x 1/2”NPT / 1 x 1”NPT.HD Entry threads: 2 x 1/2”NPT / 1 x 3/4”NPT.HG Entry threads: 2 x M20 / 1 x M25.HH Entry threads: 3 x M25.Stainless steel EXd enclosure, IP67 / NEMA4XHN Entry threads: 2 x 3/4”NPT / 1 x 1”NPT.HO Entry threads: 3 x 3/4”NPT.HP Entry threads: 2 x 1/2”NPT / 1 x 1”NPT.HR Entry threads: 2 x 1/2”NPT / 1 x 3/4”NPT.HU Entry threads: 2 x M20 / 1 x M25.HV Entry threads: 3 x M25.OutputsOT Passive transistor output - standard configuration.Power requirementsPB Lithium battery powered.PD 16 - 30V DC + sensor supply.PX Basic power input 8 - 30V DC (no real sensor supply).Hazardous areaXD Explosion proof enclosure according ATEX and IECEx (CSA and FM pending).Other optionsZF Coil input 10mVpp.ZG Coil input 5mVpp.ZX No options.The bold marked text contains the standard configuration.
Reliable