15
End Station Personal Safety Shutter TSC Design Presentation

End Station Personal Safety Shutter TSC Design Presentation

Embed Size (px)

DESCRIPTION

End Station Personal Safety Shutter TSC Design Presentation. ES PSS Assembly. Safety Requirements: Established OP 02-30. History - LBL Engineering note #10450. Different Versions: Proto Original Current - Rev. A (6mm.) - Rev. 1 (22mm.) - Rev. E (0.125”). ES PSS Assembly Design. - PowerPoint PPT Presentation

Citation preview

Page 1: End Station Personal Safety Shutter TSC Design Presentation

End Station Personal Safety ShutterTSC Design Presentation

Page 2: End Station Personal Safety Shutter TSC Design Presentation

ES PSS Assembly

Safety Requirements:

Established OP 02-30

Page 3: End Station Personal Safety Shutter TSC Design Presentation

History - LBL Engineering note #10450

Different Versions:

Proto

Original

Current

- Rev. A (6mm.)

- Rev. 1 (22mm.)

- Rev. E (0.125”)

Page 4: End Station Personal Safety Shutter TSC Design Presentation

ES PSS Assembly Design

Primary design details:

Critical dimensions remain same

Design is retro-fitable

New switches

New switch actuation design

New switch access design

Meets OP 02-30 procedure criteria

Page 5: End Station Personal Safety Shutter TSC Design Presentation

New Switch Specification

Switch Details:

“924CE1-S3”

Safety Rated

High Cycle life Reputable Manufacturer

Available

Page 6: End Station Personal Safety Shutter TSC Design Presentation

ISO Views

Page 7: End Station Personal Safety Shutter TSC Design Presentation

Upper and Lower Switch Actuation

Page 8: End Station Personal Safety Shutter TSC Design Presentation

Back Side Access and Top View

Page 9: End Station Personal Safety Shutter TSC Design Presentation

General Design Changes

Changes to address Tracking issues:

1) Documentation via an engineering notes

#10450 - MDC Specific

#10457 - General PSS Assys at ALS

2) New part number assigned, Old versions obsolete

3) Shutters need tag for exterior indication

- Name (LBL ALS ES PSS Assy)

- Part number (200863-2002)

- Serial number (unique for ever unit)

4) Print details

- Fabrication/ Assembly Procedure

- Bill of material / wire diagram

- Reference LBL Engineering note #10450

Page 10: End Station Personal Safety Shutter TSC Design Presentation

Specific Mechanical Improvements

Changes to address fabrication and reliability issues:

1) Bellows leaks -> Usage 30K cycles vs. 100K cycles design

- MDC design changes to increase number of cycles

2) Limit Switch failures -> New switches and actuation design

3) Access to switches -> New door style access

4) Paddle thickness -> Specified as 0.125” minimum

- Changes design requires new assembly

5) Assembly inconsistencies -> MDC Procedure requirement added

6) Operational issues -> MDC Testing required.

- Electrical circuit verification.

- Cycle test – at least 100 cycles.

- Paddle thickness measured.

- Documentation to be provided.

Page 11: End Station Personal Safety Shutter TSC Design Presentation

Misc. views of assembly

Page 12: End Station Personal Safety Shutter TSC Design Presentation

Front Access View

Page 13: End Station Personal Safety Shutter TSC Design Presentation

Old Switch Design

Old design / issues:

Switch not safety rated

Low cycle life

Improper actuation

No adjustability

Wire damage

Page 14: End Station Personal Safety Shutter TSC Design Presentation

ES PSS Assembly Checklist

To be completed after fabrication and delivered with each PSS assembly.

Page 15: End Station Personal Safety Shutter TSC Design Presentation

ES PSS Assembly

Safety Requirements:

Established OP 02-30

Changes have not effected these requirements or have incorporated them.