End Station Personal Safety ShutterTSC Design Presentation
ES PSS Assembly
Safety Requirements:
Established OP 02-30
History - LBL Engineering note #10450
Different Versions:
Proto
Original
Current
- Rev. A (6mm.)
- Rev. 1 (22mm.)
- Rev. E (0.125”)
ES PSS Assembly Design
Primary design details:
Critical dimensions remain same
Design is retro-fitable
New switches
New switch actuation design
New switch access design
Meets OP 02-30 procedure criteria
New Switch Specification
Switch Details:
“924CE1-S3”
Safety Rated
High Cycle life Reputable Manufacturer
Available
ISO Views
Upper and Lower Switch Actuation
Back Side Access and Top View
General Design Changes
Changes to address Tracking issues:
1) Documentation via an engineering notes
#10450 - MDC Specific
#10457 - General PSS Assys at ALS
2) New part number assigned, Old versions obsolete
3) Shutters need tag for exterior indication
- Name (LBL ALS ES PSS Assy)
- Part number (200863-2002)
- Serial number (unique for ever unit)
4) Print details
- Fabrication/ Assembly Procedure
- Bill of material / wire diagram
- Reference LBL Engineering note #10450
Specific Mechanical Improvements
Changes to address fabrication and reliability issues:
1) Bellows leaks -> Usage 30K cycles vs. 100K cycles design
- MDC design changes to increase number of cycles
2) Limit Switch failures -> New switches and actuation design
3) Access to switches -> New door style access
4) Paddle thickness -> Specified as 0.125” minimum
- Changes design requires new assembly
5) Assembly inconsistencies -> MDC Procedure requirement added
6) Operational issues -> MDC Testing required.
- Electrical circuit verification.
- Cycle test – at least 100 cycles.
- Paddle thickness measured.
- Documentation to be provided.
Misc. views of assembly
Front Access View
Old Switch Design
Old design / issues:
Switch not safety rated
Low cycle life
Improper actuation
No adjustability
Wire damage
ES PSS Assembly Checklist
To be completed after fabrication and delivered with each PSS assembly.
ES PSS Assembly
Safety Requirements:
Established OP 02-30
Changes have not effected these requirements or have incorporated them.