416
S12 - Emergency MASTER.indd 416 18/05/2018 16:06
Project Lakes College - Workington, UK
Encore LED p430
Eagle LED p434
Emergency417
S12 - Emergency MASTER.indd 417 18/05/2018 16:06
w w w .ansellu k .c omw w w .ansellu k .c om
Emerg enc y
IP65 Bulkheads
50421 50430
50434 50435
Exit Boxes
Suspended Edge IP65 Surface Edge
421421
418
S12 - Emergency MASTER.indd 418 18/05/2018 16:06
Warring ton: + 44 (0) 19 42 433333 Belfast: + 44 (0) 28 9 0 7 7 37 50
50446
Panel Pod Emergency
5044050437
Twin Spots LED Emergency Downlights
437437
419
S12 - Emergency MASTER.indd 419 18/05/2018 16:06
Deliv erDeliv erDeliv erDeliv erDesig ned toDesig ned to
420
S12 - Emergency MASTER.indd 420 18/05/2018 16:06
Warring ton: + 44 (0) 19 42 433333 Belfast: + 44 (0) 28 9 0 7 7 37 50
• Small and unobtrusive LED bulkhead• Supplied with self-adhesive
legend• O ptic design provides
optimum performance for escape route lighting
• Side and rear cable entries• Screwless gear tray for
ease of installation• V iewing distance 17 metres
Sw ift LED Bu lk h eadSupplied c/ w Legend and Integral Driver
A c c e sso r y
2 1 0
100
40
LED Information
Total (W) 3WLumens DeliveredEmergency M ode 69 lmStandard M ode 163lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
C o d e L a m p D e s c r i p t i o n
A SW T L ED / 3 M L E D 3 W M a i n t a i n e d / N o n - M a i n t a i n e d
A SBP / 1 3 . 6 V 6 0 0 m A h N i - C d R e p l a c e m e n t B a t t e r y
3YR
IP65
Mou nting Heig h t ( M)
2.546
2.352.242.24
67 .55.9
1.9 81.9 81.9 8
66
5.7 9
Transv erse to Transv erse
Transv erse to Wall
Op en ( Anti-Panic ) area ( 0.5 Lu x Minimu m) * *
Ax ial to Wall
Ax ial to Ax ial
Mou nting Heig h t ( M)
2.546
1.9 81.7-
5.94-
1.9 81.22
-
5.84.5-
Transv erse to Transv erse
Transv erse to Wall
Esc ap e rou te 2 metres w ide ( 1 Lu x minimu m) *
Ax ial to Wall
Ax ial to Ax ial
* * *
* * *
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself.
* * 0.5 lux minimum must be used for all areas larger than 60m2, the minimum value is to be measured across the area excluding 0.5m border around edge of room.
* * * Explanation of terms; Transv erse – w all -
distance to wall from to side of fitting,
Transv erse – transv erse - side to side spacing,
Ax ial – w all - distance to wall from end of
fitting, Ax ial – ax ial - end to end spacing.
421
S12 - Emergency MASTER.indd 421 18/05/2018 16:06
w w w .ansellu k .c omw w w .ansellu k .c om
ltra-slim profile LE polycarbonate bulkhead
• Supplied with self-adhesive legend
• 20mm side and rear cable entries
• H inged screwless gear tray for ease of installation
• V iewing distance 18 metres
3 5 2
110
55
A G L E D / K I TW i t h G u a r d i a n I n st a l l e d
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
* * 0.5 lux minimum must be used for areas larger than 60m² , the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
* * * Explanation of the symbols:- Transv erse - Wall Distance to wall from side of fitting Transv erse - Transv erse Side to side spacing Ax ial - Wall Distance to wall from end of fitting Ax ial - Ax ial End to end spacing
Gu ardian LED Bu lk h eadSupplied c/ w Legend and Integral Driver
C o d e L a m p D e s c r i p t i o n
A G L ED / 3 M L E D 3 W M a i n t a i n e d / N o n - M a i n t a i n e d
A G L ED / K IT S e m i - R e c e s s i n g K i t - W h i t e
A SBP / 2 3 . 6 V 1 5 0 0 m A h R e p l a c e m e n t N i - C d B a t t e r y
A c c e sso r i e s
Mou nting Heig h t ( M)
2.546
33.83.8
7 .588
33.83.8
7 .588
Transv erse to Transv erse
Transv erse to Wall
Op en ( Anti-Panic ) area ( 0.5 Lu x Minimu m) * *
Ax ial to Wall
Ax ial to Ax ial
Mou nting Heig h t ( M)
2.546
2.21.8-
5.75.6-
3.43.5-
65-
Transv erse to Transv erse
Transv erse to Wall
Esc ap e rou te 2 metres w ide ( 1 Lu x minimu m) *
Ax ial to Wall
Ax ial to Ax ial
* * *
* * *
3YR
LED Information
Total (W) 3WLumens DeliveredEmergency M ode 144lmStandard M ode 160lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
IP65
422
S12 - Emergency MASTER.indd 422 18/05/2018 16:06
Proj ec t - Lak es Colleg eCumbria, U K
423
S12 - Emergency MASTER.indd 423 18/05/2018 16:06
w w w .ansellu k .c omw w w .ansellu k .c om
Kite LED Emerg enc y Bu lk h eadSupplied with Legend and Integral Driver
2 7 0
120
45
Modern ultra-slim profile IP65 LED polycarbonate bulkhead
• Self-test as standard• Aesthetically designed for
modern appearance• Supplied with self-
adhesive legend• 20mm side and rear cable
entries• H inged screwless gear
tray for ease of installation• V iewing distance 20
metres
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
* * 0.5 lux minimum must be used for areas larger than 60m² , the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
* * * Explanation of the symbols:- Transv erse - Wall Distance to wall from side of fitting Transv erse - Transv erse Side to side spacing Ax ial - Wall Distance to wall from end of fitting Ax ial - Ax ial End to end spacing
Mou nting Heig h t ( M)
2.546
2.12.42.4
677
2.12.42.4
677
Transv erse to Transv erse
Transv erse to Wall
Op en ( Anti-Panic ) area ( 0.5 Lu x Minimu m) * *
Ax ial to Wall
Ax ial to Ax ial
Mou nting Heig h t ( M)
2.54-
21.8-
5.55-
1.81.9-
5.56-
Transv erse to Transv erse
Transv erse to Wall
Esc ap e rou te 2 metres w ide ( 1 Lu x minimu m) *
Ax ial to Wall
Ax ial to Ax ial
* * *
* * *
C o d e L a m p D e s c r i p t i o n
A K T L ED / 3 M / ST L E D 4 W M a i n t a i n e d / N o n - M a i n t a i n e d
A SBP / 1 3 . 6 V 6 0 0 m A h N i - C d R e p l a c e m e n t B a t t e r y
Se lf - T e st
A c c e sso r y
3YR ST
LED Information
Total (W) 4WLumens DeliveredEmergency M ode 7 9 lmStandard M ode 18 2lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
IP65
424
S12 - Emergency MASTER.indd 424 18/05/2018 16:06
425
S12 - Emergency MASTER.indd 425 18/05/2018 16:06
w w w .ansellu k .c omw w w .ansellu k .c om
Centu rion LED Bu lk h ead Supplied c/ w Legend and Integral Driver
• H igh lumen performance LED polycarbonate bulkhead for increased spacings
• Supplied with self-adhesive legend
• Self-test as standard• O utperforms 8 W T5 and
exceeds performance of G uardian by 56%
• 20mm conduit entry positions and rear teminal box entry
• H inged screwless gear tray for ease of installation
• V iewing distance 18 metres
• 50,000 hours average lifetime
3YR ST
Se lf - T e st
A c c e sso r y
C o d e L a m p D e s c r i p t i o n
A CEL ED / 3 M / ST L E D 6 W M a i n t a i n e d / N o n - M a i n t a i n e d
A SBP / 2 3 . 6 V 1 5 0 0 m A h N i - C d R e p l a c e m e n t B a t t e r y
Mou nting Heig h t ( M)
2.546
2.53.53.6
7 .59
9 .5
2.53.53.6
7 .59
9 .5
Transv erse to Transv erse
Transv erse to Wall
Op en ( Anti-Panic ) area ( 0.5 Lu x Minimu m) * *
Ax ial to Wall
Ax ial to Ax ial
Mou nting Heig h t ( M)
2.546
2.22.5-
78 .5-
2.53-
6.88-
Transv erse to Transv erse
Transv erse to Wall
Esc ap e rou te 2 metres w ide ( 1 Lu x minimu m) *
Ax ial to Wall
Ax ial to Ax ial
* * *
* * *
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
* * 0.5 lux minimum must be used for areas larger than 60m² , the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
* * * Explanation of the symbols:- Transv erse - Wall Distance to wall from side of fitting Transv erse - Transv erse Side to side spacing Ax ial - Wall Distance to wall from end of fitting Ax ial - Ax ial End to end spacing
3 5 2
6411
0
LED Information
Total (W) 6WLumens DeliveredEmergency M ode 151lmStandard M ode 254lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
IP65
426
S12 - Emergency MASTER.indd 426 18/05/2018 16:06
427
S12 - Emergency MASTER.indd 427 18/05/2018 16:06
w w w .ansellu k .c omw w w .ansellu k .c om
Osp rey Hig h Rac k LED Bu lk h eadSupplied c/ w Integral Driver
Modern slim profile I 65LED polycarbonatebulkhead• Compact high polishedreflector design to providereq uired light level fromhigh mounting heights• H igh performance LED’sand optical performanceallows increased spacingratios• Cold store optionincorporates an intelligentintegral heat managementsystem to operate in coldstore applications down to-30°C• Self-test as standard• Aesthetically designed formodern appearance• 20mm side and rear cableentries
3YR ST
Mou nting Heig h t ( M)
1015
--
--
51.2
2015.5
Transv erse to Transv erse
Transv erse to Wall
Esc ap e rou te 2 metres w ide ( 1 Lu x minimu m) *
Ax ial to Wall
Ax ial to Ax ial
* * *
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
* * 0.5 lux minimum must be used for areas larger than 60m² , the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
* * * Explanation of the symbols:- Transv erse - Wall Distance to wall from side of fitting Transv erse - Transv erse Side to side spacing Ax ial - Wall Distance to wall from end of fitting Ax ial - Ax ial End to end spacing
LED Information
IP65
Co ld St o r e
A c c e sso r i e s
C o d e L a m p D e s c r i p t i o n
A O SL ED / 3 M L E D 9 M a i n t a i n e d / N o n - M a i n t a i n e d
A O SL ED / 3 M / CS L E D 2 2 W M a i n t a i n e d / N o n - M a i n t a i n e d
A SBP / 1 5 3 . 6 V 4 A h N i - C d R e p l a c e m e n t B a t t e r y
A SBP / 1 6 3 . 6 V 4 A h N i - C d R e p l a c e m e n t B a t t e r y ( f o r u s e w i t h C o l d S t o r e f i t t i n g )
Total (W) 9 W 10WLumens DeliveredEmergency M ode 38 0lmStandard M ode 438 lmLumens Delivered Cold StoreEmergency M ode 38 3lmStandard M ode 554lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°Cold Store -30C° to 5C°
AO SLED/ 3M
Mou nting Heig h t ( M)
1015
5.25
14.517
5.25
1822
Transv erse to Transv erse
Transv erse to Wall
Op en ( Anti-Panic ) area ( 0.5 Lu x Minimu m) * *
Ax ial to Wall
Ax ial to Ax ial
* * *
AO SLED/ 3M
3 3 0
135
69
428
S12 - Emergency MASTER.indd 428 18/05/2018 16:06
57
Q uick and easy installation
Self-Test as standard
M aintenance free
Better spacing ratio for less fittings
Osp rey LEDHig h Rac k Bu lk h ead v s. Traditional Halog en Tw in Sp otWarehouse racking aisle scheme (15 metre ceiling height and 2 metre aisle width)
Osp rey LED 9W5 fitting s to reac h req u ired lu x lev el
Halog en Tw insp ot 2x 20W7 fitting s to reac h req u ired lu x lev el
429
S12 - Emergency MASTER.indd 429 18/05/2018 16:07
w w w .ansellu k .c omw w w .ansellu k .c om
St an d ar d
Se lf - T e st
A c c e sso r y
A E N L E D / 3 M / W
A E N L E D / 3 M / S G
C o d e L a m p D e s c r i p t i o n
A EN L ED / 3 M / W L E D 2 . 6 W M a i n t a i n e d / N o n - M a i n t a i n e d - W h i t e
A EN L ED / 3 M / SG L E D 2 . 6 W M a i n t a i n e d / N o n - M a i n t a i n e d - S i l v e r G r e y
A EN L ED / 3 M / W / ST L E D 2 . 6 W M a i n t a i n e d / N o n - M a i n t a i n e d - W h i t e
A SBP / 2 3 . 6 V 1 5 0 0 m A h N i - C d R e p l a c e m e n t B a t t e r y
• U ltra slim modern LED exit sign
• Self-test option• Neat picture frame
appearance compared to conventional fluorescent exit signs
• Supplied with all legend options - arrow down, arrow up and arrow
left/ right• V iewing distance 29
metres
LED Information
Total (W) 2.6WLumens DeliveredEmergency mode 29 lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
3 1 6
1 96
36.5
Enc ore LED Ex it Sig nSupplied c/ w Legends and Integral Driver
3YR ST
IP20
430
S12 - Emergency MASTER.indd 430 18/05/2018 16:07
Warring ton: + 44 (0) 19 42 433333 Belfast: + 44 (0) 28 9 0 7 7 37 50
1 96
Proj ec t - Harv eys Restau rantR huddlan, U K
431
S12 - Emergency MASTER.indd 431 18/05/2018 16:07
w w w .ansellu k .c omw w w .ansellu k .c om
• White steel LED exit box sign with legend
• Larger dimensions enables easy retrofit replacement of fluorescent products
• V iewing distance 37 metres
3 7 5 6 0
185
Watc h man LED Ex it Sig nSupplied c/ w Legend and Integral Driver
C o d e L a m p D e s c r i p t i o n
A W L ED / 3 M L E D 3 W M a i n t a i n e d / N o n - M a i n t a i n e d
A G 8 / L / A D L e g e n d - A r r o w D o w n
A G 8 / L / A R L e g e n d - A r r o w R i g h t
A G 8 / L / A L L e g e n d - A r r o w L e f t
A G 8 / L / A U L e g e n d - A r r o w U p
A SBP / 3 3 . 6 V 1 8 0 0 m A h N i - C d R e p l a c e m e n t B a t t e r y
L e g e n d s
Bat t e r y
3YR
LED Information
Total (W) 3WLumens DeliveredEmergency mode 48 lmCCT 6000KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
IP20
432
S12 - Emergency MASTER.indd 432 18/05/2018 16:07
Proj ec t - Th e Liq u or StoreM anchester, U K
433
S12 - Emergency MASTER.indd 433 18/05/2018 16:07
w w w .ansellu k .c omw w w .ansellu k .c om
Eag le 3-In-1 LED Ex it Sig nSupplied c/ w Integral Driver and Legend
3YR ST
• M odern, slim, 3-In-1 LED Exit Sign
• Self-test option ne fitting that enables
choice of three different mounting options :- suspension, recessed or side arm wall mounting
• V iewing distance 25 M etres
3 6 4 8 6
48.5
4 5
3 2 94 8
4 5
152
70
S e m i R e c e s s e d
S u s p e n d e d
S i d e A r m W a l l M o u n t e d
3 2 3
A E 3 L E D / 3 M / S IS e m i R e ce sse d
A E 3 L E D / 3 M / WS u sp e n d e d
A E 3 L E D / 3 M / WS i d e A r m W a l l M o u n t e d
St an d ar d
Se lf - T e st
L e g e n d s
Bat t e r y
C o d e L a m p D e s c r i p t i o n
A E3 L ED / 3 M / W L E D 2 . 5 W M a i n t a i n e d / N o n - M a i n t a i n e d - W h i t e
A E3 L ED / 3 M / SI L E D 2 . 5 W M a i n t a i n e d / N o n - M a i n t a i n e d - S i l v e r
A E3 L ED / 3 M / W / ST L E D 2 . 5 W M a i n t a i n e d / N o n - M a i n t a i n e d - W h i t e
A E3 L ED / A L A R D o u b l e S i d e d L e g e n d - A r r o w L e f t a n d R i g h t
A E3 L ED / L / A D D o u b l e S i d e d L e g e n d - A r r o w D o w n
A E3 L ED / L / A U D o u b l e S i d e d L e g e n d - A r r o w U p
A SBP / 4 3 . 6 V 8 0 0 m A h R e p l a c e m e n t N i - C d B a t t e r y
LED Information
Total (W) 2.5WLumens DeliveredEmergency mode 21lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
IP20
160
51
434
S12 - Emergency MASTER.indd 434 18/05/2018 16:07
Warring ton: + 44 (0) 19 42 433333 Belfast: + 44 (0) 28 9 0 7 7 37 50
3 3 6 1 3 0
83 1 0
160
51
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
* * 0.5 lux minimum must be used for areas larger than 60m² , the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
* * * Explanation of the symbols:- Transv erse - Wall Distance to wall from side of fitting Transv erse - Transv erse Side to side spacing Ax ial - Wall Distance to wall from end of fitting Ax ial - Ax ial End to end spacing
• Compact high performance IP65 polycarbonate surface emergency luminaire
• Self-test as standard• O ptional hanging blade
legends (supplied with self-adhesive legend as standard) for enhanced appearance
• Aesthetically designed for modern appearance
• H igh output LED performance and distribution allows maximum spacing providing reduced cost
• V iewing distance 25 metres
Harrier LED IP65 Blade Ex it Sig nSupplied c/ w Self-Adhesive Legend (O ptional Blade Legend ordered separately)
3YRST
Se lf - T e st
L e g e n d s
Bat t e r y
C o d e L a m p D e s c r i p t i o n
A H A R L ED / 3 M / ST L E D 6 W M a i n t a i n e d / N o n - M a i n t a i n e d
A H A R L ED / A L A R H a r r i e r L E D D o u b l e S i d e d L e g e n d - A r r o w L e f t a n d R i g h t
A H A R L ED / L / A D H a r r i e r L E D D o u b l e S i d e d L e g e n d - A r r o w D o w n
A H A R L ED / L / A U H a r r i e r L E D D o u b l e S i d e d L e g e n d - A r r o w U p
A SBP / 5 7 . 2 V 1 5 0 0 m A h N i - C d R e p l a c e m e n t B a t t e r y
LED Information
Total (W) 6WLumens DeliveredEmergency M ode 142lmStandard M ode 29 9 lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
IP65
435
S12 - Emergency MASTER.indd 435 18/05/2018 16:07
Proj ec t - Th e Liq u or StoreM anchester, U K
436
S12 - Emergency MASTER.indd 436 18/05/2018 16:07
Warring ton: + 44 (0) 19 42 433333 Belfast: + 44 (0) 28 9 0 7 7 37 50
• Self-test Twin LED emergency floodlight for industrial applications
• R obust white moulded enclosure
• Exceeds performance of 2x20W halogen eq uivalent
• M oulded polycarbonate heads
3 0 0 7 0
290
LED Information
Total (W) 5WLumens Delivered Emergency M ode 440lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
IP65 Ow l LED Tw in Sp otSupplied c/ w Integral Driver
3YRST
Se lf - T e st
Bat t e r y
C o d e L a m p D e s c r i p t i o n
A T SL ED / 3 N M / IP 6 5 / ST L E D 5 W N o n - M a i n t a i n e d
A SBP / 6 3 . 6 V 6 A h N i - C d R e p l a c e m e n t B a t t e r y
IP65
437
S12 - Emergency MASTER.indd 437 18/05/2018 16:07
w w w .ansellu k .c omw w w .ansellu k .c om
C o d e L a m p D e s c r i p t i o n
A T SL ED / 3 N M L E D 3 W N o n - M a i n t a i n e d
A SBP / 7 3 . 6 V 4 A h N i - C d R e p l a c e m e n t B a t t e r y
LED Tw in Sp otSupplied c/ w Integral Driver
3YR
• Twin LED emergency floodlighting for industrial applications
• Exceeds performance of 2x20W halogen eq uivalent
• R obust metal enclosure in an opal colour
• M oulded polycarbonate heads
IP20
Bat t e r y
3 1 0
1 1 3
277
LED Information
Total (W) 3WLumens DeliveredEmergency M ode 19 8 lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
438
S12 - Emergency MASTER.indd 438 18/05/2018 16:07
Warring ton: + 44 (0) 19 42 433333 Belfast: + 44 (0) 28 9 0 7 7 37 50
Condor LED Tw in Sp otSupplied c/ w Integral Driver
3YR
• Sleek modern polycarbonate moulded decorative twin spot
• Individual adj ustable LED array’s allowing the end user to aim output into the desired location
• Decorative design suitable for retail application
• Self-test as standard• Non-dimmable
IP20
ST
C o d e L a m p D e s c r i p t i o n
A CT SL ED / W / 3 N M L E D 5 W - W h i t e
A CT SL ED / B/ 3 N M L E D 5 W - B l a c k
A SBP / 6 3 . 6 V 6 A h N i - C d R e p l a c e m e n t B a t t e r y
LED Information
Total (W) 5WLumens DeliveredEmergency M ode 48 0lmCCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
3 0 0
2 2 1
5 5
A C T S L E D / W / 3 N M
A C T S L E D / B / 3 N M
439
S12 - Emergency MASTER.indd 439 18/05/2018 16:07
w w w .ansellu k .c omw w w .ansellu k .c om
Sig nal LED Emerg enc y Dow nlig h tSupplied c/ w R emote Driver and Battery Pack
3YR • Economic and compact LE Non-Maintained fi ed
downlight• White and black powder
coat paint finish• LED combines power and
green charge indicator• 3 hour emergency output• 112.4° beam angle
3 4
33
Ø 4 5
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
* * 0.5 lux minimum must be used for areas larger than 60m² , the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
* * * Explanation of the symbols:- Transv erse - Wall Distance to wall from side of fitting Transv erse - Transv erse Side to side spacing Ax ial - Wall Distance to wall from end of fitting Ax ial - Ax ial End to end spacing
IP20
A c c e sso r y
C o d e L a m p D e s c r i p t i o n
A SL ED / 3 N M L E D 1 . 5 W N o n - M a i n t a i n e d
A SL ED / 3 N M / B L E D 1 . 5 W N o n - M a i n t a i n e d
A SBP / 8 3 . 6 V 2 A h N i - C d R e p l a ce m e n t B a t t e r y
A S L E D / 3 N M
A S L E D / 3 N M / B
LED Information
Total (Watts) 1.5WLumens Delivered Emergency M odeASLED/ 3NM 137 lmASLED/ 3NM / B 107 lmBeam Angle ASLED/ 3NM 128 °ASLED/ 3NM / B 115°CCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0°C to 45°C
Mou nting Heig h t ( M)
2.54
2.54
3.53.53.23.1
8 .597
7 .5
3.53.53.23.1
8 .597
7 .5
Transv erse to Transv erse
Transv erse to Wall
Esc ap e rou te 2 metres w ide ( 1 Lu x minimu m) *
Ax ial to Wall
Ax ial to Ax ial
* * *
ASLED/ 3NM
ASLED/ 3NM / B
Mou nting Heig h t ( M)
2.546
2.546
3.63.63.6333
7 .510.5116.39
10.5
3.63.63.6333
7 .510.5116.39
10.5
Transv erse to Transv erse
Transv erse to Wall
Op en ( Anti-Panic ) area ( 0.5 Lu x Minimu m) * *
Ax ial to Wall
Ax ial to Ax ial
* * *
ASLED/ 3NM
ASLED/ 3NM / B
440
S12 - Emergency MASTER.indd 440 18/05/2018 16:07
Proj ec t - Th e Liq u or StoreM anchester, U K
441
S12 - Emergency MASTER.indd 441 18/05/2018 16:07
w w w .ansellu k .c omw w w .ansellu k .c om
Beac on LED Emerg enc y Adj u stab le Dow nlig h tSupplied c/ w R emote Driver and Battery Pack
3YR • LED Non-M aintained adj ustable die-cast
aluminium downlight• 3 hour emergency output• Power and green charge
LED are discreetly incorporated within the head
• 22.7 ° beam angle
Ø 7 8
52
6 0
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
* * 0.5 lux minimum must be used for areas larger than 60m² , the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
* * * Explanation of the symbols:- Transv erse - Wall Distance to wall from side of fitting Transv erse - Transv erse Side to side spacing Ax ial - Wall Distance to wall from end of fitting Ax ial - Ax ial End to end spacing
A c c e sso r y
C o d e L a m p D e s c r i p t i o n
A BL ED / 3 N M L E D 5 W N o n - M a i n t a i n e d
A SBP / 9 3 . 6 V 4 . 5 A h N i - C d R e p l a c e m e n t B a t t e r y
Total (Watts) 5WLumens DeliveredEmergency M ode 248 lmBeam Angle 22.7 °CCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0°C to 45°C
LED Information
IP20
Mou nting Heig h t ( M)
2.546
2.252.53
5.77 .18 .25
2.252.53
5.77 .18 .25
Transv erse to Transv erse
Transv erse to Wall
Op en ( Anti-Panic ) area ( 0.5 Lu x Minimu m) * *
Ax ial to Wall
Ax ial to Ax ial
Mou nting Heig h t ( M)
2.546
2.53-
5.256.5-
2.53-
5.256.5-
Transv erse to Transv erse
Transv erse to Wall
Esc ap e rou te 2 metres w ide ( 1 Lu x minimu m) *
Ax ial to Wall
Ax ial to Ax ial
* * *
* * *
442
S12 - Emergency MASTER.indd 442 18/05/2018 16:07
Warring ton: + 44 (0) 19 42 433333 Belfast: + 44 (0) 28 9 0 7 7 37 50
Rav en LED Emerg enc y Dow nlig h tSupplied c/ w Integral Driver and Battery Pack
3YRST
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
* * 0.5 lux minimum must be used for areas larger than 60m² , the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
* * * Explanation of the symbols:- Transv erse - Wall Distance to wall from side of fitting Transv erse - Transv erse Side to side spacing Ax ial - Wall Distance to wall from end of fitting Ax ial - Ax ial End to end spacing
9 5
• R ecessed Self-test emergency downlight
with self-contained inverter and battery pack• Integral components for fast-fit installation• O ption of escape route or open area models• H igh performance optic design• Pre-wired with 150mm
rubber insulated cable for ease of installation
• U p to 15 metres spacing between luminaires
Ø 1 1 0
109
C o d e L a m p D e s c r i p t i o n
A R A L ED / ER / 3 N M / ST L E D 3 W N o n - M a i n t a i n e d - E s c a p e R o u t e
A R A L ED / O A / 3 N M / ST L E D 3 W N o n - M a i n t a i n e d - O p e n A r e a
A SBP / 1 4 3 . 2 V L i t h i u m I r o n P h o s p h a t e B a t t e r y ( L i - F e P o 4 )
Se lf - T e st
A c c e sso r y
E m e r g e n cy d o w n l i g h t w i t h i n t e g r a li n ve r t e r a n d b a t t e r y p a ck
E sca p e R o u t e
O p e n A r e a
IP65
Mou nting Heig h t ( M)
2.546
2.5 3 2
5.4 7 .5 8 .5
2.5 3 2
5.4 7 .5 8 .5
Transv erse to Transv erse
Transv erse to Wall
Op en ( Anti-Panic ) area ( 0.5 Lu x Minimu m) * *
Ax ial to Wall
Ax ial to Ax ial
Mou nting Heig h t ( M)
2.546
55* *
1112.5
* *
55* *
1112.5
* *
Transv erse to Transv erse
Transv erse to Wall
Esc ap e rou te 2 metres w ide ( 1 Lu x minimu m) *
Ax ial to Wall
Ax ial to Ax ial
* * *
* * *LED Information
Total (Watts) 3WLumens DeliveredEmergency M odeO pen Area 149 lmEscape R oute 129 lmBeam Angle O pen Area 43.3°Escape R oute 132°CCT 6500KInput 220/ 240VH ertz 50/ 60H zO perating Temp 0C° to 40C°
443
S12 - Emergency MASTER.indd 443 18/05/2018 16:07
w w w .ansellu k .c omw w w .ansellu k .c om
A M E L E D / O A / 3 N M / S T A M E L E D / E R / 3 N M / S T / B
Merlin LED Emerg enc y Dow nlig h tSupplied c/ w R emote Driver and Battery Pack
3YR ST
ltra-low profile recessed self-test emergency downlight
• Self-test as standard• O ption of escape route or
open area models igh specification optic
design and performance allows increased spacing providing reduced cost
• U p to 17 .8 metres spacing between luminaires
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
* * 0.5 lux minimum must be used for areas larger than 60m² , the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
* * * Explanation of the symbols:- Transv erse - Wall Distance to wall from side of fitting Transv erse - Transv erse Side to side spacing Ax ial - Wall Distance to wall from end of fitting Ax ial - Ax ial End to end spacing
Ø 8 5
57
7 2
IP20
Se lf - T e st
A c c e sso r y
C o d e L a m p D e s c r i p t i o n
A M EL ED / ER / 3 N M / ST L E D 5 W N o n - M a i n t a i n e d - E s c a p e R o u t e
A M EL ED / O A / 3 N M / ST L E D 5 W N o n - M a i n t a i n e d - O p e n A r e a
A M EL ED / ER / 3 N M / ST / B L E D 5 W N o n - M a i n t a i n e d - E s c a p e R o u t e
A M EL ED / O A / 3 N M / ST / B L E D 5 W N o n - M a i n t a i n e d - O p e n A r e a
A SBP / 9 3 . 6 V 4 . 5 A h N i - C d R e p l a c e m e n t B a t t e r y
LED Information
Total (Watts) 5WLumens DeliveredEmergency M odeO pen AreaEscape R outeBeam Angle O pen AreaEscape R outeCCTInputH ertzO perating Temp
259 lm247 lm
110°140°6500K230V50/ 60H z0°C to 45°C
/ B19 1lm229 lm
108 °140°
Mou nting Heig h t ( M)
2.54
2.54
68
5.57 .5
1419 .614
19 .6
68
5.57 .5
1419 .614
19 .5
Transv erse to Transv erse
Transv erse to Wall
Esc ap e rou te 2 metres w ide ( 1 Lu x minimu m) *
Ax ial to Wall
Ax ial to Ax ial
* * *
AM ELED/ ER / 3NM / ST
AM ELED/ ER / 3NM / ST/ B
Mou nting Heig h t ( M)
2.546
2.546
34534
4.5
6.59 .511.56.3910
34534
4.5
6.59 .511.5
6910
Transv erse to Transv erse
Transv erse to Wall
Op en ( Anti-Panic ) area ( 0.5 Lu x Minimu m) * *
Ax ial to Wall
Ax ial to Ax ial
* * *
AM ELED/ O A/ 3NM / ST
AM ELED/ O A/ 3NM / ST/ B
444
S12 - Emergency MASTER.indd 444 18/05/2018 16:07
Warring ton: + 44 (0) 19 42 433333 Belfast: + 44 (0) 28 9 0 7 7 37 50
Mou nting Heig h t ( M)
2.54
2.54
----
----
4.74.7 54.54.1
10129 .511
Transv erse to Transv erse
Transv erse to Wall
Esc ap e rou te 2 metres w ide ( 1 Lu x minimu m) *
Ax ial to Wall
Ax ial to Ax ial
* * *
AFALED/ ER / 3NM / ST
AFALED/ ER / 3NM / ST/ B
Mou nting Heig h t ( M)
2.546
2.546
2.53.54
2.53.54
57 .19 .84.86.89 .8
2.53.54
2.53.54
57 .19 .84.86.89 .8
Transv erse to Transv erse
Transv erse to Wall
Op en ( Anti-Panic ) area ( 0.5 Lu x Minimu m) * *
Ax ial to Wall
Ax ial to Ax ial
* * *
AFALED/ O A/ 3NM / ST
AFALED/ O A/ 3NM / ST/ B
IP65 Falc on LED Su rfac e Emerg enc y Dow nlig h tSupplied c/ w Integral Driver and Battery Pack
3YRST
• Compact surface ultra-low profile recessed self-test emergency downlight
• Self-test as standard• Supplied with open
area and escape route interchangeable lenses
igh specification optic design and performance allows increased spacing providing reduced cost
• U p to 19 .6 metres spacing between luminaires
* 1 lux minimum must be used for all marked emergency escape routes, to be measured down the centre line of the escape route itself
* * 0.5 lux minimum must be used for areas larger than 60m² , the maximum value is to be measured across the area excluding 0.5 metre border around the edge of the room
* * * Explanation of the symbols:- Transv erse - Wall Distance to wall from side of fitting Transv erse - Transv erse Side to side spacing Ax ial - Wall Distance to wall from end of fitting Ax ial - Ax ial End to end spacing
IP65
1 6 55 5 . 7
Se lf - T e st
A c c e sso r y
C o d e L a m p D e s c r i p t i o n
A F A L ED / 3 N M / ST / IP 6 5 L E D 5 W N o n - M a i n t a i n e d
A F A L ED / 3 N M / ST / IP 6 5 / B L E D 5 W N o n - M a i n t a i n e d - B l a c k
A SBP / 1 0 3 . 6 V 3 A h N i - C d R e p l a ce m e n t B a t t e r y
LED Information
Total (Watts) 5WLumens DeliveredEmergency M odeO pen AreaEscape R outeBeam Angle O pen AreaEscape R outeCCTInputH ertzO perating Temp
152lm247 lm
9 6°140°6500K230V50/ 60H z0°C to 45°C
/ B142lm116lm
9 6°135°
O p e n A r e a L e n s E sca p e R o u t e L e n s
A F A L E D / 3 N M / S T / I P 6 5
A F A L E D / 3 N M / S T / I P 6 5 / B
445
S12 - Emergency MASTER.indd 445 18/05/2018 16:07
w w w .ansellu k .c omw w w .ansellu k .c om
T o p H o u si n g V i e w
B o t t o m H o u si n g V i e wsh o w i n g E m e r g e n cy L E DB o t t o m H o u si n g V i e wsh o w i n g E m e r g e n cy L E D
LE anel od Emergency for nfinite and Endu ranc e LED Panels
3YR ST
• Integral emergency pod to convert any new Ansell
Infinite LE and Endurance LED panel to emergency, instantly
• Simple, q uick twist and lock fi ing
• Supplied with a pre-wired 1 M etre cable for ease of installation
• Total light output of 220lm. Tri-colour LED shows green for healthy running condition, red flashing for fault conditions and white for emergency operation
• UK Patent No. GB2522285• Eu rop ean Patent Ap p lied
For No. 15165652.7 • Irish Patent Ap p lied For
No. 2015/0128• EC Reg istered Desig n No
002712232-0001
1 7 0
53
LED Information
Total (Watts) 5WLumens Delivered Emergency M ode 18 9 lmBeam Angle 120°CCT 6500KInput 230VH ertz 50/ 60H zO perating Temp 0C° to 45C°
Se lf - T e st
A c c e sso r y
C o d e L a m p D e s c r i p t i o n
A IR M L ED / P O D / 3 N M / ST L E D 5 W - C o o l W h i t e
A SBP / 1 1 3 . 6 V 4 . 5 A h N i - C d R e p l a c e m e n t B a t t e r y
STEP 2Locate and twist Panel Pod into position. Connect incoming supply to pre-leaded cable
STEP 1U nscrew coin plug from back of Ansell Infinite LE anel
IP20
446
S12 - Emergency MASTER.indd 446 18/05/2018 16:08
Proj ec t - Du c atti Sh ow roomStoke, U K
447
S12 - Emergency MASTER.indd 447 21/05/2018 15:04