Upload
rushdir
View
1.330
Download
3
Tags:
Embed Size (px)
Citation preview
Welcome!
• Heinen + Löwenstein GmbH
• Arzbacher Straße 80
• D-56130 Bad Ems
• Tel. +49 (0) 2603 9600-0
• Fax +49 (0) 2603 960050
• www.hul.de
4UTECH
4U-TECH CORPORATION SDN. BHD. (524775-V)
Presented by:
Ahmad Mohim Ahmad Khairudin
Service Centre Manager
4U-Tech Corporation Sdn Bhd - Operation Group Organization Chart Year 2009
44UU TECH
Rushdan Bin Rusmi General Manager
44UU TECH
Alkusaie Bin Abd Rahim Consultant, Business Development
Afdzal Bin Rusmi Sales & Marketing Manager
Ahmad Mohim Ahmad KhairudinService Centre Manager
Zulhilmi Bin Shahri Biomedical Technical Executive
Muhammad Salman Bin Baharom Biomedical Technical Executive
Surya Suhaimi Bin Hussein Biomedical Technical Executive
Abdul Fattah Bin Shaharudin Biomedical Technical Executive
44UU TECH
44UU TECH
44UU TECH
44UU TECH
44UU TECH
44UU TECH
44UU TECH
Presented by:
Ahmad Mohim Ahmad Khairudin
Service Centre Manager
Leon Plus – Anesthesia Unit, Workstation
Leoni 2 – Ventilator Acute, Neonate/ Pediatric
Leoni Plus – Ventilator Acute, Neonate/ Pediatric (HF)
Leoni 2 – Ventilator Acute, Neonate/Pediatric
Lifetherm 2003 – Infant Radiant Warmer
Elisa – Newborn /Adult Ventilator
Sonata – Newborn /Adult Ventilator
Elisa ICU Ventilator
General Description
• Intensiv Care Ventilator for– Adult– Pediatric (min. 5 kg)– Neonates (min. 2 kg – 6 kg)
• The system is:– Time controlled– Volume constant– Pressure cycled– Software controlled
General Description
• Expiration Valve is electromechanically controlled
• Expiration Valve is electromechanical locked
• Flowtrigger
• Permanent Byflow
• spontaneaus breathing in all ventilation modes
Features
• Individual ventilation strategies• Compact size ensures the highest performance combined
with a minimum need of floor space• Removable display• TFT, multicoloured• Patient Trigger visualized with different colour• Intuitive menu navigation • Comprehensive safety-concept (unintentional adjustments are
not possible, automatic patient detection, internal battery pack)
Features
• Innovative pre-oxygenation function to reduce oxygenation determined dystelectasis
• Continous Leakage measurement and Observation• Single Gas Option (only Air, only Oxygen possible)• Autoset Function (Alarm setting)• Stable expiration valve, quick and easy to remove for
cleaning and disinfection• Disposable flowsensors or other consumables has
been consciously rejected (economical)
Features
• Automatic adjustement of Starting Parameters related to the Bodyweight
• Automatical initiated Systemtest (45 sec. complete)
• Direct Start up Function in Emergency Case• Integrated Nebulizer• OCV Function• Special Measurement Tools• NIV (Non invasive Ventilation Mode)
• Nursecall
Ventilation modes
• VCV (Volume controlled Mode)
• AVCV (Assisted Volume controlled Mode)
• SIMV – VC (Synchroniced Intermittend Mandatory Ventilation – Volume Constant)
• Dyn - Bi – Level (Dynamic BiLevel Mode)
• Bi – Level (Pressure controlled)
• CPAP / PSV (Continous Positive Airway Pressure – Pressure supported Ventilation)
• NIV – Mode (Non – Invasive Ventilation) Option
V C VS I M V - V CB i - L e v e l V G
C P A P / P S VP r e v i o u s m e n u
B i - L e v e l
Special Functions
• OCV Function (Oxygen cell calibration during Ventilation)
• Inspiration Hold (X – Ray, Extension)
• Expiration Hold (X – Ray, PEEP intrinsic Tool)
• Manual Breath
• Nebulizer
• APD (Automatic Patient Detection)
• Tube Compensation
• ASR (Automatic Suction Routine)
Measured Values
• Standard Values– MV-E (Minute Volume expiratoric)
– VTe (expiratoric Tidalvolume)
– Ppeak– Pmin– O2 (Oxygen in percentage)
– Rate (frequency per minute)
Additional Measured Values
• Pressure:– peak– plateau– mean– min (smallest measured pressure
during ventilation)
– PEEP (Positive endexpiratory Pressure)
– PEEPi (intrinsic PEEP)
• Volumina:– VTi (inspiratoric Tidalvolume)
– MV (Minute Volume)
– MVsp (Minute Volume spontaneous)
– Rate sp (Frequency spontaneous)
• Dynamics:– Resistance– Compliance– RSBI (Rapid shallow breathing Index)
Alarming
Alarm Limits for Infant– MV max.– MV min.– Plimit– Pmax
Manual Setting of Alarm Limits Autoset Function (adaption to the actual measured values)
Alarm Limits Adult and Pediatric – MV max.– MV min.– Plimit– Pmax– AF max.– AF min.
Graphs and Loops
• Real time Measurement• Freezing Function (Loop)• Two graphs at a time• One Loop at a time• V / P and F / V
Graphs and Loops Visualization Patient Trigger
Trending
• Numerical Trending• Event Log
Different SolutionsIntegration of compressor Wall mounting
External Battery Backup
Thank you very much for your open interest
4U-Tech Corporation Sdn Bhd28A, Tgk 1, Jln Pekaka 8/3,Kota Damansara, PJSelangorTel. +6 (03) 6140 5258Fax +6 (03) 6156 0265 www.4utechcorp.comwww.hul.de