3
EL-WiFi-21CFR-TH+ High Accuracy 21CFR Remote WiFi Temperature and Humidity Sensor • Can be installed as part of a 21CFR compliant system with addional controls including permission-based use, authority level sign-off and full system audit -20 to +60°C (-4 to +140°F) temperature and 0 to 100% humidity measurement range Wirelessly stream and view data on the EasyLog 21CFR Cloud • Configurable high and low alarms with indicator The EL-WIFI-21CFR-TH+ measures the temperature and humidity of the environment in which it is situated. Data is streamed wirelessly over any compable WiFi network to be viewed on the EasyLog 21CFR Cloud. During configuraon, the sensor will search for an exisng wireless network whilst physically connected to the PC. It can then be placed anywhere within range of the network. If the sensor temporarily loses connecvity with the network, it will log readings unl it is able to communicate again with the EasyLog 21CFR Cloud (max 30 days at 10-second sample interval). The unit is freestanding, but it can be aached to a wall or surface using the bracket provided. The sensor is IEEE 802.11bgn (2.4GHz) compliant, supports WEP, WPA/WPA2 encrypon and enterprise networks (PEAP, TTLS, FAST). SPECIFICATIONS Minimum Typical Maximum Unit Baery life >6 Months USB supply voltage 4.5 5 5.5 Vdc Operang temperature range -20 (-4) +60 (+140) °C (°F) Logging period (user configurable) 10 sec 10 min 12 hrs Transmission period (user configurable) 1 min 1 hr 24 hrs Temperature measurement range -20 (-4) +60 (+140) °C (°F) Temperature measurement resoluon 0.01 °C Temperature display resoluon 0.01 Temperature accuracy ±0.2/ ±0.4* (+5 to +60/ +41 to +140) ±0.8/ ±1.6* (-20 to +60/ -4 to +140) °C/°F Humidity measurement range 0 100 %RH Humidity measurement resoluon 0.1 %RH Humidity display resoluon 0.1 Humidity accuracy (@ 25°C) ±1.8* (10 to 90) ±4.0* (0 to 100) %RH Dimensions 82 x 70 x 36mm (3.22 x 2.75 x 1.41”) *Please refer to the charts in this datasheet for more detailed accuracy specifications. 21CFR COMPLIANCE Permission based use and access Authority based acon sign-off Data records cannot be edited or deleted Complete system audit trail For a detailed compliance checklist, please visit www.lascarelectronics.com/data-brochures ACCESSORIES PSU-5VDC-USB-USA USB Mains Power Adapter for USA PSU USB-UK USB Mains Power Adapter for UK PSU USB-EU USB Mains Power Adapter for EU INCLUDED IN THE BOX EL-WIFI WALL BRACKET Wall mounng bracket for EL-WiFi sensors CABLE USB A-MICRO B USB Type A to Micro B CALIBRATION CERTIFICATES NOW AVAILABLE Lascar now offers a Traceable Calibraon Cerficate Service on Temperature Data Loggers. Using reference equipment which has been calibrated by a UKAS/NIST accredited laboratory and using apparatus traceable to naonal or internaonal standards. For more informaon, please visit www.lascarelectronics.com/calibraon.

EL-WiFi-21CFR-TH+ · 2019-10-13 · The EL-WIFI-21CFR-TH+ measures the temperature and humidity of the environment in which it is situated. Data is streamed wirelessly over any compatible

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EL-WiFi-21CFR-TH+ · 2019-10-13 · The EL-WIFI-21CFR-TH+ measures the temperature and humidity of the environment in which it is situated. Data is streamed wirelessly over any compatible

www.easylogcloud.com

Issue 1 11/2016 Page 1 of 3

EL-WiFi-21CFR-TH+High Accuracy 21CFR Remote WiFi Temperature and Humidity Sensor

• Canbeinstalledaspartofa21CFRcompliantsystemwithadditionalcontrols includingpermission-baseduse,authoritylevelsign-offandfullsystemaudit • -20 to +60°C (-4 to +140°F) temperature and 0 to 100% humidity measurement range • Wirelessly stream and view data on the EasyLog 21CFR Cloud • Configurablehighandlowalarmswithindicator

The EL-WIFI-21CFR-TH+ measures the temperature and humidity of the environment inwhichitissituated.DataisstreamedwirelesslyoveranycompatibleWiFinetwork tobeviewedontheEasyLog21CFRCloud.Duringconfiguration,thesensorwillsearchforanexistingwirelessnetworkwhilstphysicallyconnectedtothePC.Itcanthenbeplacedanywherewithinrangeofthenetwork.Ifthesensortemporarilylosesconnectivitywiththenetwork,itwilllogreadingsuntilitisabletocommunicateagainwith the EasyLog 21CFR Cloud (max 30 days at 10-second sample interval). The unit is freestanding,butitcanbeattachedtoawallorsurfaceusingthebracketprovided.

ThesensorisIEEE802.11bgn(2.4GHz)compliant,supportsWEP,WPA/WPA2encryptionandenterprisenetworks(PEAP,TTLS,FAST).

SPECIFICATIONS

Minimum Typical Maximum Unit

Battery life >6 Months

USB supply voltage 4.5 5 5.5 Vdc

Operating temperature range -20 (-4) +60 (+140) °C (°F)

Logging period (user configurable) 10 sec 10 min 12 hrs

Transmission period (user configurable) 1 min 1 hr 24 hrs

Temperature measurement range -20 (-4) +60 (+140) °C (°F)

Temperature measurement resolution 0.01 °C

Temperature display resolution 0.01

Temperature accuracy ±0.2/ ±0.4* (+5 to +60/ +41 to +140)

±0.8/ ±1.6*(-20 to +60/-4 to +140)

°C/°F

Humidity measurement range 0 100 %RH

Humidity measurement resolution 0.1 %RH

Humidity display resolution 0.1

Humidity accuracy (@ 25°C) ±1.8* (10 to 90)

±4.0*(0 to 100) %RH

Dimensions 82 x 70 x 36mm (3.22 x 2.75 x 1.41”)

*Please refer to the charts in this datasheet for more detailed accuracy specifications.

21CFRCOMPLIANCE

Permission based use and access Authority based action sign-off Data records cannot be edited or deleted Complete system audit trail For a detailed compliance checklist, please visit www.lascarelectronics.com/data-brochures

ACCESSORIES

PSU-5VDC-USB-USA USBMainsPowerAdapterforUSA

PSU USB-UK USBMainsPowerAdapter for UK

PSU USB-EU USBMainsPowerAdapter for EU

INCLUDEDINTHEBOX

EL-WIFI WALL BRACKET

WallmountingbracketforEL-WiFisensors

CABLE USB A-MICRO B USBTypeAtoMicroB

CALIBRATIONCERTIFICATESNOWAVAILABLELascarnowoffersaTraceableCalibrationCertificateServiceonTemperatureDataLoggers.UsingreferenceequipmentwhichhasbeencalibratedbyaUKAS/NISTaccreditedlaboratoryandusingapparatustraceabletonationalorinternationalstandards.Formoreinformation,pleasevisitwww.lascarelectronics.com/calibration.

Page 2: EL-WiFi-21CFR-TH+ · 2019-10-13 · The EL-WIFI-21CFR-TH+ measures the temperature and humidity of the environment in which it is situated. Data is streamed wirelessly over any compatible

www.easylogcloud.com

Issue 1 11/2016 Page 2 of 3

EL-WiFi-21CFR-TH+High Accuracy 21CFR Remote WiFi Temperature and Humidity Sensor

21CFRWIFISENSORSOFTWAREEasyLog21CFRWiFisoftware*isavailableasafreedownloadfromwww.easylogcloud.com.Easytoinstallanduse,EasyLog21CFRWiFiSensorSoftwareallowseasysensorset-upandconnectionofsensorstoaWiFinetworkandtheEasyLog21CFRCloud.

EASYLOG21CFRCLOUD21CFRCloudsubscriptiondeliversalloftheflexibilityofaremotemonitoringsystem:Interact with sensors via any internet-enabled device; manage and monitor sensors; accesseventlogsandsetupemailalerts;assignauthorisationlevelstouseraccountsandviewcomprehensiveaudittrailrecords.UnlikethestandardEasyLogCloudservice,21CFRCloudincludesothercontrolssuchaspermission-baseduse,authoritysign-offandfullsystemaudittoensuredatamonitoredandcollectedisregulatedto21CFRPart11 standard.

ACloudaccountsubscriptioniscreatedduringtheWiFisensorset-upprocessusingEasyLog21CFRWiFiSensorSoftware.21CFRWiFiSensorsareonlycompatiblewiththeEasyLog21CFRCloudwww.easylogcloud.com.

BATTERYLIFEANDPOWERSUPPLYThebatterycanberecharged(unitmustbebetween0-40°C)viaaPC,aUSB+5Vwalladapter,oraportableUSBbattery packusingtheUSBleadprovided.ItcanalsobepermanentlypoweredbyaUSBwalladapterorUSBbatterypack.Readings maybeaffectedwhiletheinternalbatteryisbeingcharged.However,oncecharged,continuedconnectionofthechargerwillhavenoeffect.

Batterylifeisdependenton:transmissionperiod,WiFiencryptionmethod,WiFiencryptionkeyrotationfrequency(determinedby the router/access point), signal strength between router/access point and WiFi device, presence volume and type of WiFi trafficfromotherdevices,samplerateandoperatingtemperature.

Specificationsliabletochangewithoutpriorwarning *RequiresWindows7,8.1,10

Download the latest version of the software free of charge from www.easylogcloud.com

Authority sign-off on actions

Detailed data reporting Detailed system audit reporting

Page 3: EL-WiFi-21CFR-TH+ · 2019-10-13 · The EL-WIFI-21CFR-TH+ measures the temperature and humidity of the environment in which it is situated. Data is streamed wirelessly over any compatible

www.easylogcloud.com

Issue 1 11/2016 Page 3 of 3

EL-WiFi-21CFR-TH+High Accuracy 21CFR Remote WiFi Temperature and Humidity Sensor

SENSORACCURACY&INFORMATION

0

20

40

60

80

100

-40 -20 0 20 40 60 80 100 120Temperature (°C)

Rela

tive

Hum

idity

(%)

Max. Range

Normal Range

ΔT (°C)

± 0.0

± 0.5

± 1.0

± 1.5

± 2.0

-40 -20 0 20 40 60 80Temperature (°C)

maximum accuracytypical accuracy

± 0

± 2

± 4

± 6

± 8

± 10

0 10 20 30 40 50 60 70 80 90 100Relative Humidity (%RH)

maximum accuracytypical accuracy

ΔRH (%RH)

EL-USB-2+, EL-USB-2-LCD+

100 ±3 ±2.5 ±3 ±3.590 ±2 ±2.5 ±380 ±2.5 ±370 ±2.5 ±2 ±2.56050 ±2 ±1.840302010 ±2.5 ±2

0 ±3 ±2.5

0 10 20 30 40 50 60 70 80

)HR%( ytidi

muH evitaleR

Temperature (°C)

Typicalandmaximaltoleranceat25°Cforrelativehumidity.

0

20

40

60

80

100

-40 -20 0 20 40 60 80 100 120Temperature (°C)

Rela

tive

Hum

idity

(%)

Max. Range

Normal Range

ΔT (°C)

± 0.0

± 0.5

± 1.0

± 1.5

± 2.0

-40 -20 0 20 40 60 80Temperature (°C)

maximum accuracytypical accuracy

± 0

± 2

± 4

± 6

± 8

± 10

0 10 20 30 40 50 60 70 80 90 100Relative Humidity (%RH)

maximum accuracytypical accuracy

ΔRH (%RH)

EL-USB-2+, EL-USB-2-LCD+

100 ±3 ±2.5 ±3 ±3.590 ±2 ±2.5 ±380 ±2.5 ±370 ±2.5 ±2 ±2.56050 ±2 ±1.840302010 ±2.5 ±2

0 ±3 ±2.5

0 10 20 30 40 50 60 70 80

)HR%( ytidi

muH evitaleR

Temperature (°C)

Typical and maximal tolerance for temperature sensor in °C.

0

20

40

60

80

100

-40 -20 0 20 40 60 80 100 120Temperature (°C)

Rela

tive

Hum

idity

(%)

Max. Range

Normal Range

ΔT (°C)

± 0.0

± 0.5

± 1.0

± 1.5

± 2.0

-40 -20 0 20 40 60 80Temperature (°C)

maximum accuracytypical accuracy

± 0

± 2

± 4

± 6

± 8

± 10

0 10 20 30 40 50 60 70 80 90 100Relative Humidity (%RH)

maximum accuracytypical accuracy

ΔRH (%RH)

EL-USB-2+, EL-USB-2-LCD+

100 ±3 ±2.5 ±3 ±3.590 ±2 ±2.5 ±380 ±2.5 ±370 ±2.5 ±2 ±2.56050 ±2 ±1.840302010 ±2.5 ±2

0 ±3 ±2.5

0 10 20 30 40 50 60 70 80

)HR%( ytidi

muH evitaleR

Temperature (°C)

Typicalaccuracyofrelativehumiditymeasurementsgivenin%RH for temperatures 0 to 80°C.

0

20

40

60

80

100

-40 -20 0 20 40 60 80 100 120Temperature (°C)

Rela

tive

Hum

idity

(%)

Max. Range

Normal Range

ΔT (°C)

± 0.0

± 0.5

± 1.0

± 1.5

± 2.0

-40 -20 0 20 40 60 80Temperature (°C)

maximum accuracytypical accuracy

± 0

± 2

± 4

± 6

± 8

± 10

0 10 20 30 40 50 60 70 80 90 100Relative Humidity (%RH)

maximum accuracytypical accuracy

ΔRH (%RH)

EL-USB-2+, EL-USB-2-LCD+

100 ±3 ±2.5 ±3 ±3.590 ±2 ±2.5 ±380 ±2.5 ±370 ±2.5 ±2 ±2.56050 ±2 ±1.840302010 ±2.5 ±2

0 ±3 ±2.5

0 10 20 30 40 50 60 70 80

)HR%( ytidi

muH evitaleR

Temperature (°C)

Operatingconditions

Long term exposure to humidity levels outside of the ‘normal’rangemaytemporarilyoffsetRHmeasurements(±3%RH after 60 hours). Once returned to less extremeconditionsthedevicewillslowlyreturntowardscalibrationstate.

Whentrackingchanges inambientconditions, the responsetimeof thehumidity sensor inyourdata logger isapproximately20minutestoreach90%ofthereading.However,ifyouaremeasuringstepchangesinhumidity(forexampleifcalibratingtheproduct)itisadvisedthatyouleavetheunitforuptofourhourstoensurethatithasenoughtimetosettleatthenewlevel.

Itisworthrememberingthatthevalueofrelativehumidityisofcoursesensitivetotemperaturevariation.Asanexample,atarelativehumidityof~90%RHatambienttemperature,avariationintemperatureof1°Cwillresultinachangeofupto-5%RH.Thereforewhencomparingmultipledevicesorcalibratingthem,anytemperaturevariationsmustbeconsidered.