SANCH ORGANISATION
SANCH Inverter Series
Low noise, high performance,multi-functional alternatingcurrent inverters
Drive Solutions International
for more: efesotomasyon - sanch inverter
Corporate introduction
SANCH Electric Corporation, together with three leading enterprises and several affiliatedorganisations in China and Taiwan has been established to supply “Total Project Solutions” in IndustrialAutomation. Sanch is geared to integrate the development, manufacture and systems engineering forlocal and international clients alike.
Our professional teams of engineering, product development, manufacturing and integration staff,devote themselves to the development and application of motor, electric, electronic, microelectronic,information and control technology.
We continue to maintain close co-operation with scientific research institutions both at home andabroad, in order to provide “intelligent” products that not only offer the best solutions, but also have a“humanised” approach to functionality.
At present, our manufacturing capacity is over 100,000 devices per annum. This includes productssuch as:
Industrial Human Machine Interface units (HMI)
A/C Frequency Inverters (INVERTER)
Intelligent Control Instruments
Programmable Logic Controllers (PLC)
Peripheral equipment for Industrial Process Control (IPC)
Microcomputer Controllers for various applications
and many others.
In order to service the Chinese market, we have already established dozens of marketing,distribution agents and service organisations, to cover the Northern, Eastern, Central and Southernareas. A Pathway Management System and CRM Customer Relationship Centre with high-efficiencylogistic and linkage service has also been established.
SANCH have already applied their range of products and services to the following industries; textile,dye, ceramic, transportation, building, metallurgy, chemical, light, military, etc.
SANCH philosophy is to continually improve the electric management platform to account for allfacets of applications, thus maximising the competitiveness of technology, quality, service andefficiently in accordance with the principle of satisfying our customers and creating excellent products.
SANCH actively promote a philosophy of maximising production outputs and yet minimising energyconsumption,using modern technological developments.
Our goal is to achieve “Automation–Energy Saving–Green World”, and we will try our best toimprove the environment and society as a whole.
Hsieh Yu Kuang – President
Corporate headquarters: Quanzhou, Fujian, Peoples Republic of China
TiV Technology • Interact ion • Vital ity
for more: efesotomasyon - sanch inverter
TechnologyInteractionVitality
TiV
for more: efesotomasyon - sanch inverter
Products Introduction
Product FeaturesSANCH manufacture 4 series of alternating current motor drives: S800, SA, SE, S3000. All of themincorporate high speed microprocessors and Sine-wave Pulse Width Modulation (SPWM) technology.The drives utilize sensorless control by the Vector method with Voltage/Frequency being developed.New generation IGBT components are used at the core of these units. This results in drives which aresmaller, more energy efficient and with a reduction of Electro-Magnetic Interference (EMI).
Model Instruction
S 8 0 0 - 2 0 0 4 1 AName of Product Series: 2:220V Applicable motor: Input VoltageVariable Frequency Drive capacity 1: 1-PHASE Version
002:0.2kW 3: 3-PHASE004:0.4kW007:0.75kW
S A - 4 0 5 5 BName of Product Series: 2:220V Applicable Power: EditionMultifunctional and 4:440V 007:0.75kW 075:7.5kWGeneral- applications 015:1.5kW 110:11kW
022:2.2kW 150:15kW037:3.7kW 185:18.5kW055:5.5kW 220:22kW
S E - 2 0 0 4 1 AName of Product Series: 2:220V Applicable Power: Input VoltageHigh performance and 002:0.2kW 1: 1-PHASE Editionmini-type 004:0.4kW
007:0.75kW
S 3 0 0 0 - 3 0 0 G / 3 7 0 P 4 3 AEdition
Name of Product Series: Type of Frequency InverterMultifunctional Vector Type/ G: Constant TorqueMultifunctional Fan and Water pump P: Variable Torque Input Voltage
Applicable Power: 43:440V 3-PHASE055:5.5kW 370:37kW075:7.5kW 450:45kW110:11kW 550:55kW150:15kW 750:75kW185:18.5kW 900:90kW220:22kW 1100:110kW300:30kW
1
for more: efesotomasyon - sanch inverter
Products Introduction
S800 Series
Low Noise High-Performance
Rated Voltage (V): 220V single/three phase Power Range (kW): 0.2kW~0.75kW Output Frequency: 1.0~400HzFeatures: Compact and easy to install Easy to operate 4-level speed auto torque compensation Auto slip compensation Parameter locking/reset adjustable carrier Uses interface design of port making wiring easier Frequency setting potentiometer RS-485 in-line with built in interface
SE Series
Mini-type with High-Performance and Low Noise
Rated Voltage (v): 220v single phase Power Range (kW): 0.2 kW~0.75kW Output Frequency: 1.0~400HzFeatures: Compact and easy-to-install & operate Frequency setting potentiometer attached to operator Group parameters, easier operation Adjusting accelerating/decelerating time automatically Compact, 2HP (include that less than 2HP) is fan cooled 4-Level speed and 4-level programmable operation Modbus communication format Parameters cipher-locked S-curve, setting the accelerating/decelerating time independently
SA Series
Multifunctional and General Applications
Rated Voltage (V): 220V / single phase 220V/three phase 440V/phase Power Range (kW):0.75~22kW Output Frequency: 1.0~400HzFeatures: Automatic torque compensation RS-485 in-line interface build-in 2-level accelerating/decelerating time Automatic slip compensation, automatic voltage regulation (AVR) 8-level preset table speed Restart after instantaneous power-off All-dimensional protection
S3000 Series
Multifunctional Vector Type/Multifunctional Fan and Water pump
Rated Voltage (V): 440V three phase Power Range (kW): 5.5kW~110kW Output Frequency: 0.1~400HzFeatures: Automatic setting for acceleration / deceleration 16-level preset table speed, switch of 4-level accelerating/decelerating time RS-485 in-line interface build-in Automatic control of motor parameters, precise location control Automatic voltage regulation (AVR) All-dimensional protection Include PID circuit control Senseless Vector control Program and vector control of fan and water pump makes it more economical
2
for more: efesotomasyon - sanch inverter
Technical Specification [S800 and SE Series]
Input Voltage S800 Single-phase 220V 0r 3 Phase 220VSE Series Single-phase 220V
Model S800-2 1002 004 007
Model SE-2 1Applicable Motor Power (kW) 0.2 0.4 0.75
Rated output capacity (kVA) ) 0.6 1.0 1.6Rated output current (A) 1.6 2.5 4.2Maximum output voltage (V) Three-phase corresponding input voltageRange of output frequency (Hz) 1.0~400HzRated input current (A) 4.9 6.5 9.7Admissible variation range of Single-phase power supply 200-240V 50/60Hzinput voltageVariation range of power ±5%supply frequencyControl mode SVPWM spatial vector modulation (carrier frequency
3kHz~10kHz)Resolution of output frequency 0.1HzTorque characteristic Torque and speed drop compensation function, trigger
torque can be up to 150% in 5HzOverload tolerance One minute under 150% of Rated output currentAccelerating and 0.1~600 seconds (can be set independently)decelerating timeV/F curve Random V/F curve settingAction adjustment to avoid Set by the percent of Rated current, 20~200%losing speed
Panel operating Set by button or V, RExternal signal Potentiometer 5kΩ / 0.5W, DC 0~+10V (input impedance
47 kΩ), 4~20mA (output impedance 250Ω), multifunction input selection 1~3 (3-level speed; jog, up/down
instruction), communication settingPanel operating Set by RUN, STOP buttonExternal signal MO,M1 ,M2, M3 combined to all sorts of mode to operate;
RS-485 communication portMultifunction input signal Level speed instruction 0~3 selection, Jog instruction,
disable instruction of accelerating and decelerating, switch instruction of first, second accelerating and
decelerating, counter, program running, selection of external B.B. (NC, NO)
Multifunction output signal Operating frequency, setting frequency, counter reached inoperating, null speed, abnormal indication in B.B.,
LOCAL/REMOTE indication, program running indicationOther Functions AVR function, S-curve, avoiding over-voltage and over-
current speed losing, abnormal record check, carrier frequency adjustment, reverse disable setting, direct
current setting, starting frequency setting, restart after instantaneous power-off, upper and lower limits of
frequency, parameter locking / resettingProtective Function Over-voltage, over-current, low-voltage, overload limits,
electronic thermocouple, overheat, self-check, ground protection, abnormal port
Type of Cooling Air-blast coolingUsing location Lower than 1000m, indoor (keep from corrosive gases,
liquids and dust)Environment temperature -10C~40°C (no dewing and icing)Storage temperature -20°C ~60°CHumidity Below 90%RH (no dewing)Vibration 9.80665m/s2 below 20Hz (1G) 5.88 m/s2 below 20~50Hz (0.6G)
Operatingsetting signal
Frequencysetting signal
Output
Pow
er Supply
Control C
haracteristicO
perating Characteristic
Environm
ent
3
for more: efesotomasyon - sanch inverter
Terminal Wiring Diagram [S800 and SE Series]
Wiring part of alternating current motor drive is divided into main circuit and control circuit. User should connectthe circuitry according to the following wiring circuit.
The standard wiring diagram of default S800 and SE series alternating current motor drive is listed as follows. Ifoperated by digital control panel, there is only power circuit wiring terminal.
Main Circuit Power Supply
Multi-function indication output contacts120VAC/28VDC3AFactory default: fault indication
1:+EV2:GND3:SG-4:SG+
Main circuit (power)terminal
Control circuit terminal
Please use shielded cable
Motor
IM3~
U/T1
V/T2
W/T3
R(L1)
S(L2)
T(L3)
R(L1)
S(L2)
T(L3)
RA
RC
6 1
RS-485
Communication port
MCCB
+18V
+18V
+18V
+18V
FWorward/Stop M0
Reverse/Stop M1
Reset M2
Multi-step 1 M3
Common Signal GND
4.7K
4.7K
4.7K
4.7K
Factory default settings
Power Supply for Potentiometer+10V 10mA MAX
Master Frequency SettingAnolog Voltage
0~10VDCVR:3k~5k
Analog current 4~20mA
AVI
GND
VR
3
2
1
4
RJ-11
Note: Do not plug a Modem or telephone line to the RS-485 communication port, permanentdamage may result. Terminals 1 & 2 are the power source for the optional copy keypad andshould not be used while using RS-485 communication.
S800
R(L1)
S(L2)
R(L1)
S(L2)
MCCBSE
for more: efesotomasyon - sanch inverter
Specification [SA Series]
220V Single Phase/3 Phase series
Model SA- (_) 007 015 022
Maximum applicable output 0.75 1.5 2.2power of motor (kW)
Maximum applicable output 1 2 3power of motor (HP)
Rated output capacity (kVA) 1.9 2.5 4.2
Rated output current (A) 5.0 6.5 11
Output frequency range 0.1~400HZ
Overload tolerance Keep 60 seconds under 150% of Rated output current
Maximum output voltage Corresponding input power supply
PH number, voltage, Single phase/ Three phase, 200-240VAC, 50/60Hzfrequency
Admissible variation range Voltage: ±15% frequency: ±5%of voltage, frequency
Input current (A) 11/7.4 15/10 27/15
Cooling System Air-blast cooling
Output
Intput
440V Single Phase/3 Phase series
Model SA- (_) 007 015 022 037 055 075 110 150 185 220
Maximum applicable output 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22power of motor (kW)
Maximum applicable output 1 2 3 5 7.5 10 15 20 25 30power of motor (HP)
Rated output capacity (kVA) 2.3 3.2 4.2 6.3 9.9 13.7 18.3 24.4 28.9 34.3
Rated output current (A) 3.0 4.2 5.5 8.2 13 18 24 32 38 45
Output frequency range 0.1~400HZ
Overload tolerance Keep 60 seconds under 150% of Rated output current
Maximum output voltage Corresponding input power supply
PH number, voltage, Three phase, 380-480VAC, 50/60Hzfrequency
Admissible variation range Voltage: ±15% frequency: ±5%of voltage, frequency
Input current (A) 4.2 6.0 7.2 8.5 14 20.6 28 30 39 49
Cooling System Air-blast cooling
Output
Intput
5
for more: efesotomasyon - sanch inverter
Specification [SA Series]
Control mode Using SPWM spatial vector modulating technology
Output frequency range 0.1~400Hz
Frequency setting resolution 0.1Hz
Output frequency resolution 0.1Hz
PWM carrier frequency Adjust from 3kHz to 15kHz
Torque enhancing Automatic torque enhancement and automatic slip compensation, starting torque can be up to 150% of rated torque in 2Hz
Jumping frequency Three points set from 0.1~400Hz
Accelerating/decelerating time 0.1~600 seconds (2-level accelerating/decelerating time can be set independently)
Avoid position of losing speed Set as 50~200% of rated current according to load characteristic of motor
Direct current braking Operating from 0.1-60Hz when stopped, braking current is 0-100% of rated current, starting time is 0-5 seconds, stopping time is 0-25 seconds
Rising braking torque 20% (external optional braking resistor can be up to 125%) (built-in for 1-1 OHP braking electro-crystal and external braking unit module for 15-60HP)
V/F curve Set table V/F curve
Digit operator Set by button
External terminal 0-5VDC/0-10VDC, 4-20Madc, in-line communication port (RS-485)
Digit operator Set by RUN STOP JOG button
External terminal 2-line (Fwd/Stop, Rev/Stop. Fwd/Rev) / 3-line operating, inching operation, in-line communication port (RS-485)
Intelligent input terminal Switch of 8-level preset table speed, switch of first/second accelerating/decelerating time; no external breaking input in accelerating/decelerating,
inching operation; increasing/decreasing frequency terminal setting, count terminal
Intelligent output terminal Speed is not zero in operating when reached output frequency; external breakingindication is displayed when counter and over-torque is outputted, low-voltage
checking, operating mode indication, abnormal fault output, external abnormal breaking
Analog Signal Output Corresponding practical output frequency or output current
Fault Signal Port Connect “ON” when alternating current driver faulted (a relay with “C” terminal or two open output)
Built-in Function Upper and lower limit setting of output frequency, restarting after instantaneous power-off and abnormal fault; time setting of S curve accelerating/decelerating, automatic voltage regulating output adjustment; digit frequency output signal,
abnormal record, parameter locking, parameter factory setting; prohibit reversal, avoid losing speed under over-current and over-voltage, electronic
heat-driving electricity
Protection Function Over-voltage, over-current, low-voltage, external abnormal breaking input, motor overload, ground over-current, overload and overheat of driver
Digit Operator Include eight function keys, 7-level display with five digits, 5-condition LED;preset table frequency, practical output frequency and current displayed, user-set
unit; parameter browse, modification and locking, abnormal fault display; can operating, stop, reset, positive/reversal, job
Operating environment -10˚C ~+40˚C (dust protector should be opened in +40˚C -+50˚C )temperature
Storage temperature -20˚C -+60˚C
Operating environment humidity Below 90%RH (no dewing)
Mounting height Lower than 1000m, no corrosive gases, liquids, dusts
Vibrancy 9.80665m/s2 below20Hz (1G), 5.88 m/s2 in 20~5QHz (0.6G)
Operatingsetting signal
Frequencysetting signal
Control C
haracteristicO
perating Characteristic
Environm
ent
6
for more: efesotomasyon - sanch inverter
Terminal Wiring Diagram [SA Series]
Wiring part of alternating current motor is divided into main circuit and control circuit. User cansee the terminal of main circuit and control circuit after lifting the external cover. User shouldconnect the circuitry according to the following wiring circuit.
The standard wiring diagram of SA series alternating current motor drive is listed as follows.If operated by digital control panel (IP-03, IP-05), there is only main circuit wiring terminal.
Multifunction input No. 1 1
Multifunction input No. 2 1
Multifunction input No. 3 1
REV/STOP REV/STOP 2
FWD/STOP RUN/STOP 2
Abnormal Reset
External Abnormal
Input Signal Triggered by Counter 3
Digit Frequency Meter 4
Digit Signal Common Port
R
S
T
+EV
M11
M12
M13
REV
FWD
RST
EF
TRG
DFM
DCM
+10V
AV1
AC1
ACM
U
V
W
AFM
ACM
RA
RB
RC
MO1
MO2
MCM
SG+
SG-
R
S
T
Accessory Power Supply
(Single-phase can be input byany of the two terminals
Power Supply
N P1 P/ B1 B2(+)
Short-Circuit Sheet
DC reactorBraking Resisttance (Optional)
Induction Motor
Grounding
6Analog Frequency / Current Meter
7Multifunctional Indication Output Portbelow AC 250V 2Abelow DC 30V 2A
8Multifunctional PHC Output Portbelow 48V 50mA
0V
RS-485 SerialCommunication Interface
Signal + Port
Signal - Port9 Computer
Analog VoltageFrequency Instruction0~+10V1K~5K
Analog CurrentFrequency Instruction4~20mA Analog Signal Common Port
Main Circuit Terminal Control Circuit Terminal
AC MOTOR DRIVE
53
21
7
HH
for more: efesotomasyon - sanch inverter
Specification [S3000 Series]
Output R
atedP
ower
Control C
haracteristicP
rotection Characteristic
Environm
ent
Input Voltage Level 440V level
Model S3000-_______43__ 055 075 110 150 185 220 300 370 450 550 750
Apply for rated power of 3- φmotor (kW) 5.5 7.5 11 15 18.5 22 30 37 45 55 75
Apply for rated power of 3- φmotor (HP) 7.5 10 15 20 25 30 40 50 60 75 100
Constant torque output current (A) 13 18 24 32 38 45 60 73 91 110 150
Variable torque output current (A) 16 22 30 40 47 56 75 91 1113 138 188
Rated output capacity (kVA) 9.9 14 18 24 29 34 46 56 69 80 100
Maximum output voltage(V) Three-phase power supply 380~440V corresponding to input voltage
Rated input voltage/frequency 380/400/415/440 VAC three phase, 50/60 Hz
Operating voltage/frequency 340~500VAC, 47~63 Hz
Control system Selection of sine wave PWM1: vector control; 2: torque control; 3: V/F control
Activating torque Activating torque is more than 150% in 0.5Hz
Control range of speed 1:100 (can be up to 1:1000 when have external PG)
Control precision of speed ±0.5% (can be up to ±0.02%)
Speed reactivity 5Hz (can be up to 30Hz under vector control)
Maximum output frequency (Hz) 0.00 to 400.00 Hz
Frequency output precision Digit instruction ±0.005%, analog instruction ±0.5%
Frequency setting resolution Digit instruction 0.01 Hz, analog instruction: maximum output frequency is 1/1000 (bit)
Torque limit Maximum 200% torque current
Torque precision ±5%
Accelerating/decelerating time 0.00~600.00 seconds/ 0.0~6000.00 seconds
V/F curve Random V/F curve based on four points & quadratic curve
Frequency setting signal +10V, ± 10V, 4~20mA, pulse wave input
Dynamic brake About 20%
Motor protection Electronic thermocouple protection
Over-current protection Current restrain 170%, over-current protection 200% of rated current
Ground protection for current Current leakage protection; 50% peak value of rated currentleakage
Overload capacity Constant/variable torque 150% for 60 seconds; 200% for 2 seconds
Voltage protection Over-voltage position: Vdc>400/800 V; low-voltage position: Vdc<200/400 V
Over-voltage protection for input Surge wave absorber (MOV)power supply
Over-heat protection Built-in temperature sensor
Instantaneous power-off Parameter setting can be up to 5 secondscompensation
Protection level NEMA1/IP21
Operating temperature -10°C~40°C for UL & -10°C~50°C for CE
Storage temperature -20°C~60°C
Humidity Below 90% RH (non-condensing)
Vibration 1 .OG below 20Hz, 0.6G at 20-60 Hz
Cooling system Air-blast cooling (RUN, STOP)
Mounting height Lower than 1000m,Keep from corrosive gases, liquid and d H
for more: efesotomasyon - sanch inverter
Terminal Wiring Diagram [S3000 Series]
Wiring part of frequency inverter is divided into main circuit and control circuit.
User can see the terminal of main circuit and control circuit after removing the casing cover.User should connect the circuitry according to the following wiring circuit
The standard wiring diagram of S3000 is listed as follows:
Multifunctional 240VAC 2.5AContact Output 120VAC 5A
24VDC 5A
Factory setting is ‘Fault Instruction’
Factory setting is ‘Instruction inOperating’
Multifunctional Contact Output(Open Output) 48VDC50mA
Factory setting is ‘Frequency ReachIndication’
Factory setting Is ‘Driver ReadyIndication’
Optical Coupling Output CommonPort
Digit Frequency Output TerminalFactory magnification is set as 1:1
Duty=50%10VDC
Digit Signal Common Terminal
Multifunctional Analog OutputTerminalFactory Setting is ‘OutputFrequency’0~10VDC/2mA
Analog Signal Common Port
R(L1)
S(L2)
T(L3)
RB
RC
24V
FWD
REV
Mi1
Mi2
Mi3
Mi4
Mi5
Mi6
DCM
+10VPower Supply for Frequency Setting
+10V 20mA
AVIMain Speed Instruction
0~10V (47KΩ)
ACI
AUI
ACM
P1 P2 B
Braking Resistance (Optional)
Motor
M3~
U(T1)
V(T2)
W(T3)
RA
RB
RC
MRA
MRC
Mo1
Mo2
MCM
DFM
DCM
AFM
ACM
RS-485Serial Communication
Multifunctional Input Term
inal
Breaker without Fuse Wire
R
S
T
NFB
SA
MC
MCONOFF
Recommended protectioncircuit for abnormal orinstantaneous power-off
Factory setting is ‘Sink’
FWD/Stop
REV/Stop
Multi-level Speed Instruction 1
Multi-level Speed Instruction 2
Multi-level Speed Instruction 3
Multi-level Speed Instruction 4
Multi-level Speed Instruction 5
Multi-level Speed Instruction 6
Common Terminal of Digit Signal
Factory setting
Sink Mode*Voltage can’t be directly input to the above signal
3
2
1
5K
4~20mA
-10~+10V
Analog Signal Common Port
*Communication pin definition: pln1:no connected pin2: GND pin3: SG- pin4: SG+ pin5:/pin6: no connected
9
for more: efesotomasyon - sanch inverter
H2
H1H
C W1W
D1
D
UNIT: mm
Model H H1 H2 W W1 D D1 C
S800-20021A
S800-20041A 135.3 123.9 – 72.7 59.7 140.5 132.2 4.6
S800-20071A
SE-20021A
SE-20041A 132.0 126.1 48.5 68.0 61.9 131.0 122.0 5.0
SE-20071A
SA Series
H1C
H
WW1
D
W W1 H H1 D C mass remarkMODEL mm kgSA-2007BSA-2015BSA-4007BSA-4015B 126.5 113.6 174 159.4 144.5 5.5 1.55SA-4022BSA-4007CSA-4015CSA-4022CSA-2022SA-4037 190.5 175.1 225 207.2 159 5.5 2.55SA-4055SA-2022B 132 119.5 236 205 163 5.5 3.0SA-4037BSA-4037C 132 119.5 236 205 171 5.5 3.9SA-4055CSA-4055B 132 119.5 236 205 192 5.5 4.0SA-4075CSA-4075 203.3 185.3 323.3 308 180 6.5 7.0SA-4110 7.5SA-4075BSA-4110B 200 186.2 320 300.6 194.5 7.0 6.0SA-4150CSA-4150 10.5SA-4150BSA-4185 250 225.5 403 3835 216 5.5 11SA-4185BSA-4220SA-4220B
Overall Dimension Drawing
S800 SE Series
LENGTH
Using fan
UNIT: mm
10
H1H
W1 W
D1 D
C
for more: efesotomasyon - sanch inverter
Overall Dimension Drawing
3000 Series (7.5HP ~ 10HP)
W D W1
C
H H1
UNIT: mm
Model H H1 W W1 D C
S3000-055G/075P43A320 300.6 200.2 186.2 194.5 7.0
S3000-075G/110P43A
3000 Series (15HP ~ 30HP)
W1 C
H1
H
W
UNIT: mm
Model H H1 W W1 D C
S3000-110G/150P43A
S3000-150G/185P43A403 383.5 250 225.5 216 10.0
S3000-185G/220P43A
S3000-220G/300P43A
11
D
for more: efesotomasyon - sanch inverter
UNIT: mm
Overall Dimension Drawing
3000 Series (40HP ~ 50HP)
WW1
DC
W2
C
H H1
Model H H1 W W1 W2 D C
S3000-300G/370P43A553 530 266 210 180 277.1 10
S3000-370G/450P43A
UNIT: mmW
W1D
C
W2
C
H H1
Model H H1 W W1 W2 D C
S3000-450G/550P43A652.6 630 2308.2 250 220 282 10
S3000-550G/750P43A
3000 Series (60HP ~ 75HP)
12
for more: efesotomasyon - sanch inverter
International OfficePhone: +61 3 9795 2887Fax: +61 3 9795 7882Mobile: +61 419 424 246
Business CentreRoom 505, Fudan Technology Building11, Guo Tai Road, Shanghai, 200433 PRCPhone: +86 21 5169 6555Fax: +86 21 6140 0501
Factory Headquarters3, Zixin Road, Jiangnan High Tech ParkLicheng District, Quanzhou City, FujianProvince PRCPhone: +86 595 2898 3312Fax: +86 595 2898 3388
Contents subject to change without notice
Drive Solutions International
SISC2006
for more: efesotomasyon - sanch inverter