16
SANCH ORGANISATION SANCH Inverter Series Low noise, high performance, multi-functional alternating current inverters Drive Solutions International for more: efesotomasyon - sanch inverter

Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Embed Size (px)

Citation preview

Page 1: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

SANCH ORGANISATION

SANCH Inverter Series

Low noise, high performance,multi-functional alternatingcurrent inverters

Drive Solutions International

for more: efesotomasyon - sanch inverter

Page 2: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Corporate introduction

SANCH Electric Corporation, together with three leading enterprises and several affiliatedorganisations in China and Taiwan has been established to supply “Total Project Solutions” in IndustrialAutomation. Sanch is geared to integrate the development, manufacture and systems engineering forlocal and international clients alike.

Our professional teams of engineering, product development, manufacturing and integration staff,devote themselves to the development and application of motor, electric, electronic, microelectronic,information and control technology.

We continue to maintain close co-operation with scientific research institutions both at home andabroad, in order to provide “intelligent” products that not only offer the best solutions, but also have a“humanised” approach to functionality.

At present, our manufacturing capacity is over 100,000 devices per annum. This includes productssuch as:

Industrial Human Machine Interface units (HMI)

A/C Frequency Inverters (INVERTER)

Intelligent Control Instruments

Programmable Logic Controllers (PLC)

Peripheral equipment for Industrial Process Control (IPC)

Microcomputer Controllers for various applications

and many others.

In order to service the Chinese market, we have already established dozens of marketing,distribution agents and service organisations, to cover the Northern, Eastern, Central and Southernareas. A Pathway Management System and CRM Customer Relationship Centre with high-efficiencylogistic and linkage service has also been established.

SANCH have already applied their range of products and services to the following industries; textile,dye, ceramic, transportation, building, metallurgy, chemical, light, military, etc.

SANCH philosophy is to continually improve the electric management platform to account for allfacets of applications, thus maximising the competitiveness of technology, quality, service andefficiently in accordance with the principle of satisfying our customers and creating excellent products.

SANCH actively promote a philosophy of maximising production outputs and yet minimising energyconsumption,using modern technological developments.

Our goal is to achieve “Automation–Energy Saving–Green World”, and we will try our best toimprove the environment and society as a whole.

Hsieh Yu Kuang – President

Corporate headquarters: Quanzhou, Fujian, Peoples Republic of China

TiV Technology • Interact ion • Vital ity

for more: efesotomasyon - sanch inverter

Page 3: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

TechnologyInteractionVitality

TiV

for more: efesotomasyon - sanch inverter

Page 4: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Products Introduction

Product FeaturesSANCH manufacture 4 series of alternating current motor drives: S800, SA, SE, S3000. All of themincorporate high speed microprocessors and Sine-wave Pulse Width Modulation (SPWM) technology.The drives utilize sensorless control by the Vector method with Voltage/Frequency being developed.New generation IGBT components are used at the core of these units. This results in drives which aresmaller, more energy efficient and with a reduction of Electro-Magnetic Interference (EMI).

Model Instruction

S 8 0 0 - 2 0 0 4 1 AName of Product Series: 2:220V Applicable motor: Input VoltageVariable Frequency Drive capacity 1: 1-PHASE Version

002:0.2kW 3: 3-PHASE004:0.4kW007:0.75kW

S A - 4 0 5 5 BName of Product Series: 2:220V Applicable Power: EditionMultifunctional and 4:440V 007:0.75kW 075:7.5kWGeneral- applications 015:1.5kW 110:11kW

022:2.2kW 150:15kW037:3.7kW 185:18.5kW055:5.5kW 220:22kW

S E - 2 0 0 4 1 AName of Product Series: 2:220V Applicable Power: Input VoltageHigh performance and 002:0.2kW 1: 1-PHASE Editionmini-type 004:0.4kW

007:0.75kW

S 3 0 0 0 - 3 0 0 G / 3 7 0 P 4 3 AEdition

Name of Product Series: Type of Frequency InverterMultifunctional Vector Type/ G: Constant TorqueMultifunctional Fan and Water pump P: Variable Torque Input Voltage

Applicable Power: 43:440V 3-PHASE055:5.5kW 370:37kW075:7.5kW 450:45kW110:11kW 550:55kW150:15kW 750:75kW185:18.5kW 900:90kW220:22kW 1100:110kW300:30kW

1

for more: efesotomasyon - sanch inverter

Page 5: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Products Introduction

S800 Series

Low Noise High-Performance

Rated Voltage (V): 220V single/three phase Power Range (kW): 0.2kW~0.75kW Output Frequency: 1.0~400HzFeatures: Compact and easy to install Easy to operate 4-level speed auto torque compensation Auto slip compensation Parameter locking/reset adjustable carrier Uses interface design of port making wiring easier Frequency setting potentiometer RS-485 in-line with built in interface

SE Series

Mini-type with High-Performance and Low Noise

Rated Voltage (v): 220v single phase Power Range (kW): 0.2 kW~0.75kW Output Frequency: 1.0~400HzFeatures: Compact and easy-to-install & operate Frequency setting potentiometer attached to operator Group parameters, easier operation Adjusting accelerating/decelerating time automatically Compact, 2HP (include that less than 2HP) is fan cooled 4-Level speed and 4-level programmable operation Modbus communication format Parameters cipher-locked S-curve, setting the accelerating/decelerating time independently

SA Series

Multifunctional and General Applications

Rated Voltage (V): 220V / single phase 220V/three phase 440V/phase Power Range (kW):0.75~22kW Output Frequency: 1.0~400HzFeatures: Automatic torque compensation RS-485 in-line interface build-in 2-level accelerating/decelerating time Automatic slip compensation, automatic voltage regulation (AVR) 8-level preset table speed Restart after instantaneous power-off All-dimensional protection

S3000 Series

Multifunctional Vector Type/Multifunctional Fan and Water pump

Rated Voltage (V): 440V three phase Power Range (kW): 5.5kW~110kW Output Frequency: 0.1~400HzFeatures: Automatic setting for acceleration / deceleration 16-level preset table speed, switch of 4-level accelerating/decelerating time RS-485 in-line interface build-in Automatic control of motor parameters, precise location control Automatic voltage regulation (AVR) All-dimensional protection Include PID circuit control Senseless Vector control Program and vector control of fan and water pump makes it more economical

2

for more: efesotomasyon - sanch inverter

Page 6: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Technical Specification [S800 and SE Series]

Input Voltage S800 Single-phase 220V 0r 3 Phase 220VSE Series Single-phase 220V

Model S800-2 1002 004 007

Model SE-2 1Applicable Motor Power (kW) 0.2 0.4 0.75

Rated output capacity (kVA) ) 0.6 1.0 1.6Rated output current (A) 1.6 2.5 4.2Maximum output voltage (V) Three-phase corresponding input voltageRange of output frequency (Hz) 1.0~400HzRated input current (A) 4.9 6.5 9.7Admissible variation range of Single-phase power supply 200-240V 50/60Hzinput voltageVariation range of power ±5%supply frequencyControl mode SVPWM spatial vector modulation (carrier frequency

3kHz~10kHz)Resolution of output frequency 0.1HzTorque characteristic Torque and speed drop compensation function, trigger

torque can be up to 150% in 5HzOverload tolerance One minute under 150% of Rated output currentAccelerating and 0.1~600 seconds (can be set independently)decelerating timeV/F curve Random V/F curve settingAction adjustment to avoid Set by the percent of Rated current, 20~200%losing speed

Panel operating Set by button or V, RExternal signal Potentiometer 5kΩ / 0.5W, DC 0~+10V (input impedance

47 kΩ), 4~20mA (output impedance 250Ω), multifunction input selection 1~3 (3-level speed; jog, up/down

instruction), communication settingPanel operating Set by RUN, STOP buttonExternal signal MO,M1 ,M2, M3 combined to all sorts of mode to operate;

RS-485 communication portMultifunction input signal Level speed instruction 0~3 selection, Jog instruction,

disable instruction of accelerating and decelerating, switch instruction of first, second accelerating and

decelerating, counter, program running, selection of external B.B. (NC, NO)

Multifunction output signal Operating frequency, setting frequency, counter reached inoperating, null speed, abnormal indication in B.B.,

LOCAL/REMOTE indication, program running indicationOther Functions AVR function, S-curve, avoiding over-voltage and over-

current speed losing, abnormal record check, carrier frequency adjustment, reverse disable setting, direct

current setting, starting frequency setting, restart after instantaneous power-off, upper and lower limits of

frequency, parameter locking / resettingProtective Function Over-voltage, over-current, low-voltage, overload limits,

electronic thermocouple, overheat, self-check, ground protection, abnormal port

Type of Cooling Air-blast coolingUsing location Lower than 1000m, indoor (keep from corrosive gases,

liquids and dust)Environment temperature -10C~40°C (no dewing and icing)Storage temperature -20°C ~60°CHumidity Below 90%RH (no dewing)Vibration 9.80665m/s2 below 20Hz (1G) 5.88 m/s2 below 20~50Hz (0.6G)

Operatingsetting signal

Frequencysetting signal

Output

Pow

er Supply

Control C

haracteristicO

perating Characteristic

Environm

ent

3

for more: efesotomasyon - sanch inverter

Page 7: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Terminal Wiring Diagram [S800 and SE Series]

Wiring part of alternating current motor drive is divided into main circuit and control circuit. User should connectthe circuitry according to the following wiring circuit.

The standard wiring diagram of default S800 and SE series alternating current motor drive is listed as follows. Ifoperated by digital control panel, there is only power circuit wiring terminal.

Main Circuit Power Supply

Multi-function indication output contacts120VAC/28VDC3AFactory default: fault indication

1:+EV2:GND3:SG-4:SG+

Main circuit (power)terminal

Control circuit terminal

Please use shielded cable

Motor

IM3~

U/T1

V/T2

W/T3

R(L1)

S(L2)

T(L3)

R(L1)

S(L2)

T(L3)

RA

RC

6 1

RS-485

Communication port

MCCB

+18V

+18V

+18V

+18V

FWorward/Stop M0

Reverse/Stop M1

Reset M2

Multi-step 1 M3

Common Signal GND

4.7K

4.7K

4.7K

4.7K

Factory default settings

Power Supply for Potentiometer+10V 10mA MAX

Master Frequency SettingAnolog Voltage

0~10VDCVR:3k~5k

Analog current 4~20mA

AVI

GND

VR

3

2

1

4

RJ-11

Note: Do not plug a Modem or telephone line to the RS-485 communication port, permanentdamage may result. Terminals 1 & 2 are the power source for the optional copy keypad andshould not be used while using RS-485 communication.

S800

R(L1)

S(L2)

R(L1)

S(L2)

MCCBSE

for more: efesotomasyon - sanch inverter

Page 8: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Specification [SA Series]

220V Single Phase/3 Phase series

Model SA- (_) 007 015 022

Maximum applicable output 0.75 1.5 2.2power of motor (kW)

Maximum applicable output 1 2 3power of motor (HP)

Rated output capacity (kVA) 1.9 2.5 4.2

Rated output current (A) 5.0 6.5 11

Output frequency range 0.1~400HZ

Overload tolerance Keep 60 seconds under 150% of Rated output current

Maximum output voltage Corresponding input power supply

PH number, voltage, Single phase/ Three phase, 200-240VAC, 50/60Hzfrequency

Admissible variation range Voltage: ±15% frequency: ±5%of voltage, frequency

Input current (A) 11/7.4 15/10 27/15

Cooling System Air-blast cooling

Output

Intput

440V Single Phase/3 Phase series

Model SA- (_) 007 015 022 037 055 075 110 150 185 220

Maximum applicable output 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22power of motor (kW)

Maximum applicable output 1 2 3 5 7.5 10 15 20 25 30power of motor (HP)

Rated output capacity (kVA) 2.3 3.2 4.2 6.3 9.9 13.7 18.3 24.4 28.9 34.3

Rated output current (A) 3.0 4.2 5.5 8.2 13 18 24 32 38 45

Output frequency range 0.1~400HZ

Overload tolerance Keep 60 seconds under 150% of Rated output current

Maximum output voltage Corresponding input power supply

PH number, voltage, Three phase, 380-480VAC, 50/60Hzfrequency

Admissible variation range Voltage: ±15% frequency: ±5%of voltage, frequency

Input current (A) 4.2 6.0 7.2 8.5 14 20.6 28 30 39 49

Cooling System Air-blast cooling

Output

Intput

5

for more: efesotomasyon - sanch inverter

Page 9: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Specification [SA Series]

Control mode Using SPWM spatial vector modulating technology

Output frequency range 0.1~400Hz

Frequency setting resolution 0.1Hz

Output frequency resolution 0.1Hz

PWM carrier frequency Adjust from 3kHz to 15kHz

Torque enhancing Automatic torque enhancement and automatic slip compensation, starting torque can be up to 150% of rated torque in 2Hz

Jumping frequency Three points set from 0.1~400Hz

Accelerating/decelerating time 0.1~600 seconds (2-level accelerating/decelerating time can be set independently)

Avoid position of losing speed Set as 50~200% of rated current according to load characteristic of motor

Direct current braking Operating from 0.1-60Hz when stopped, braking current is 0-100% of rated current, starting time is 0-5 seconds, stopping time is 0-25 seconds

Rising braking torque 20% (external optional braking resistor can be up to 125%) (built-in for 1-1 OHP braking electro-crystal and external braking unit module for 15-60HP)

V/F curve Set table V/F curve

Digit operator Set by button

External terminal 0-5VDC/0-10VDC, 4-20Madc, in-line communication port (RS-485)

Digit operator Set by RUN STOP JOG button

External terminal 2-line (Fwd/Stop, Rev/Stop. Fwd/Rev) / 3-line operating, inching operation, in-line communication port (RS-485)

Intelligent input terminal Switch of 8-level preset table speed, switch of first/second accelerating/decelerating time; no external breaking input in accelerating/decelerating,

inching operation; increasing/decreasing frequency terminal setting, count terminal

Intelligent output terminal Speed is not zero in operating when reached output frequency; external breakingindication is displayed when counter and over-torque is outputted, low-voltage

checking, operating mode indication, abnormal fault output, external abnormal breaking

Analog Signal Output Corresponding practical output frequency or output current

Fault Signal Port Connect “ON” when alternating current driver faulted (a relay with “C” terminal or two open output)

Built-in Function Upper and lower limit setting of output frequency, restarting after instantaneous power-off and abnormal fault; time setting of S curve accelerating/decelerating, automatic voltage regulating output adjustment; digit frequency output signal,

abnormal record, parameter locking, parameter factory setting; prohibit reversal, avoid losing speed under over-current and over-voltage, electronic

heat-driving electricity

Protection Function Over-voltage, over-current, low-voltage, external abnormal breaking input, motor overload, ground over-current, overload and overheat of driver

Digit Operator Include eight function keys, 7-level display with five digits, 5-condition LED;preset table frequency, practical output frequency and current displayed, user-set

unit; parameter browse, modification and locking, abnormal fault display; can operating, stop, reset, positive/reversal, job

Operating environment -10˚C ~+40˚C (dust protector should be opened in +40˚C -+50˚C )temperature

Storage temperature -20˚C -+60˚C

Operating environment humidity Below 90%RH (no dewing)

Mounting height Lower than 1000m, no corrosive gases, liquids, dusts

Vibrancy 9.80665m/s2 below20Hz (1G), 5.88 m/s2 in 20~5QHz (0.6G)

Operatingsetting signal

Frequencysetting signal

Control C

haracteristicO

perating Characteristic

Environm

ent

6

for more: efesotomasyon - sanch inverter

Page 10: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Terminal Wiring Diagram [SA Series]

Wiring part of alternating current motor is divided into main circuit and control circuit. User cansee the terminal of main circuit and control circuit after lifting the external cover. User shouldconnect the circuitry according to the following wiring circuit.

The standard wiring diagram of SA series alternating current motor drive is listed as follows.If operated by digital control panel (IP-03, IP-05), there is only main circuit wiring terminal.

Multifunction input No. 1 1

Multifunction input No. 2 1

Multifunction input No. 3 1

REV/STOP REV/STOP 2

FWD/STOP RUN/STOP 2

Abnormal Reset

External Abnormal

Input Signal Triggered by Counter 3

Digit Frequency Meter 4

Digit Signal Common Port

R

S

T

+EV

M11

M12

M13

REV

FWD

RST

EF

TRG

DFM

DCM

+10V

AV1

AC1

ACM

U

V

W

AFM

ACM

RA

RB

RC

MO1

MO2

MCM

SG+

SG-

R

S

T

Accessory Power Supply

(Single-phase can be input byany of the two terminals

Power Supply

N P1 P/ B1 B2(+)

Short-Circuit Sheet

DC reactorBraking Resisttance (Optional)

Induction Motor

Grounding

6Analog Frequency / Current Meter

7Multifunctional Indication Output Portbelow AC 250V 2Abelow DC 30V 2A

8Multifunctional PHC Output Portbelow 48V 50mA

0V

RS-485 SerialCommunication Interface

Signal + Port

Signal - Port9 Computer

Analog VoltageFrequency Instruction0~+10V1K~5K

Analog CurrentFrequency Instruction4~20mA Analog Signal Common Port

Main Circuit Terminal Control Circuit Terminal

AC MOTOR DRIVE

53

21

7

HH

for more: efesotomasyon - sanch inverter

Page 11: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Specification [S3000 Series]

Output R

atedP

ower

Control C

haracteristicP

rotection Characteristic

Environm

ent

Input Voltage Level 440V level

Model S3000-_______43__ 055 075 110 150 185 220 300 370 450 550 750

Apply for rated power of 3- φmotor (kW) 5.5 7.5 11 15 18.5 22 30 37 45 55 75

Apply for rated power of 3- φmotor (HP) 7.5 10 15 20 25 30 40 50 60 75 100

Constant torque output current (A) 13 18 24 32 38 45 60 73 91 110 150

Variable torque output current (A) 16 22 30 40 47 56 75 91 1113 138 188

Rated output capacity (kVA) 9.9 14 18 24 29 34 46 56 69 80 100

Maximum output voltage(V) Three-phase power supply 380~440V corresponding to input voltage

Rated input voltage/frequency 380/400/415/440 VAC three phase, 50/60 Hz

Operating voltage/frequency 340~500VAC, 47~63 Hz

Control system Selection of sine wave PWM1: vector control; 2: torque control; 3: V/F control

Activating torque Activating torque is more than 150% in 0.5Hz

Control range of speed 1:100 (can be up to 1:1000 when have external PG)

Control precision of speed ±0.5% (can be up to ±0.02%)

Speed reactivity 5Hz (can be up to 30Hz under vector control)

Maximum output frequency (Hz) 0.00 to 400.00 Hz

Frequency output precision Digit instruction ±0.005%, analog instruction ±0.5%

Frequency setting resolution Digit instruction 0.01 Hz, analog instruction: maximum output frequency is 1/1000 (bit)

Torque limit Maximum 200% torque current

Torque precision ±5%

Accelerating/decelerating time 0.00~600.00 seconds/ 0.0~6000.00 seconds

V/F curve Random V/F curve based on four points & quadratic curve

Frequency setting signal +10V, ± 10V, 4~20mA, pulse wave input

Dynamic brake About 20%

Motor protection Electronic thermocouple protection

Over-current protection Current restrain 170%, over-current protection 200% of rated current

Ground protection for current Current leakage protection; 50% peak value of rated currentleakage

Overload capacity Constant/variable torque 150% for 60 seconds; 200% for 2 seconds

Voltage protection Over-voltage position: Vdc>400/800 V; low-voltage position: Vdc<200/400 V

Over-voltage protection for input Surge wave absorber (MOV)power supply

Over-heat protection Built-in temperature sensor

Instantaneous power-off Parameter setting can be up to 5 secondscompensation

Protection level NEMA1/IP21

Operating temperature -10°C~40°C for UL & -10°C~50°C for CE

Storage temperature -20°C~60°C

Humidity Below 90% RH (non-condensing)

Vibration 1 .OG below 20Hz, 0.6G at 20-60 Hz

Cooling system Air-blast cooling (RUN, STOP)

Mounting height Lower than 1000m,Keep from corrosive gases, liquid and d H

for more: efesotomasyon - sanch inverter

Page 12: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Terminal Wiring Diagram [S3000 Series]

Wiring part of frequency inverter is divided into main circuit and control circuit.

User can see the terminal of main circuit and control circuit after removing the casing cover.User should connect the circuitry according to the following wiring circuit

The standard wiring diagram of S3000 is listed as follows:

Multifunctional 240VAC 2.5AContact Output 120VAC 5A

24VDC 5A

Factory setting is ‘Fault Instruction’

Factory setting is ‘Instruction inOperating’

Multifunctional Contact Output(Open Output) 48VDC50mA

Factory setting is ‘Frequency ReachIndication’

Factory setting Is ‘Driver ReadyIndication’

Optical Coupling Output CommonPort

Digit Frequency Output TerminalFactory magnification is set as 1:1

Duty=50%10VDC

Digit Signal Common Terminal

Multifunctional Analog OutputTerminalFactory Setting is ‘OutputFrequency’0~10VDC/2mA

Analog Signal Common Port

R(L1)

S(L2)

T(L3)

RB

RC

24V

FWD

REV

Mi1

Mi2

Mi3

Mi4

Mi5

Mi6

DCM

+10VPower Supply for Frequency Setting

+10V 20mA

AVIMain Speed Instruction

0~10V (47KΩ)

ACI

AUI

ACM

P1 P2 B

Braking Resistance (Optional)

Motor

M3~

U(T1)

V(T2)

W(T3)

RA

RB

RC

MRA

MRC

Mo1

Mo2

MCM

DFM

DCM

AFM

ACM

RS-485Serial Communication

Multifunctional Input Term

inal

Breaker without Fuse Wire

R

S

T

NFB

SA

MC

MCONOFF

Recommended protectioncircuit for abnormal orinstantaneous power-off

Factory setting is ‘Sink’

FWD/Stop

REV/Stop

Multi-level Speed Instruction 1

Multi-level Speed Instruction 2

Multi-level Speed Instruction 3

Multi-level Speed Instruction 4

Multi-level Speed Instruction 5

Multi-level Speed Instruction 6

Common Terminal of Digit Signal

Factory setting

Sink Mode*Voltage can’t be directly input to the above signal

3

2

1

5K

4~20mA

-10~+10V

Analog Signal Common Port

*Communication pin definition: pln1:no connected pin2: GND pin3: SG- pin4: SG+ pin5:/pin6: no connected

9

for more: efesotomasyon - sanch inverter

Page 13: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

H2

H1H

C W1W

D1

D

UNIT: mm

Model H H1 H2 W W1 D D1 C

S800-20021A

S800-20041A 135.3 123.9 – 72.7 59.7 140.5 132.2 4.6

S800-20071A

SE-20021A

SE-20041A 132.0 126.1 48.5 68.0 61.9 131.0 122.0 5.0

SE-20071A

SA Series

H1C

H

WW1

D

W W1 H H1 D C mass remarkMODEL mm kgSA-2007BSA-2015BSA-4007BSA-4015B 126.5 113.6 174 159.4 144.5 5.5 1.55SA-4022BSA-4007CSA-4015CSA-4022CSA-2022SA-4037 190.5 175.1 225 207.2 159 5.5 2.55SA-4055SA-2022B 132 119.5 236 205 163 5.5 3.0SA-4037BSA-4037C 132 119.5 236 205 171 5.5 3.9SA-4055CSA-4055B 132 119.5 236 205 192 5.5 4.0SA-4075CSA-4075 203.3 185.3 323.3 308 180 6.5 7.0SA-4110 7.5SA-4075BSA-4110B 200 186.2 320 300.6 194.5 7.0 6.0SA-4150CSA-4150 10.5SA-4150BSA-4185 250 225.5 403 3835 216 5.5 11SA-4185BSA-4220SA-4220B

Overall Dimension Drawing

S800 SE Series

LENGTH

Using fan

UNIT: mm

10

H1H

W1 W

D1 D

C

for more: efesotomasyon - sanch inverter

Page 14: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

Overall Dimension Drawing

3000 Series (7.5HP ~ 10HP)

W D W1

C

H H1

UNIT: mm

Model H H1 W W1 D C

S3000-055G/075P43A320 300.6 200.2 186.2 194.5 7.0

S3000-075G/110P43A

3000 Series (15HP ~ 30HP)

W1 C

H1

H

W

UNIT: mm

Model H H1 W W1 D C

S3000-110G/150P43A

S3000-150G/185P43A403 383.5 250 225.5 216 10.0

S3000-185G/220P43A

S3000-220G/300P43A

11

D

for more: efesotomasyon - sanch inverter

Page 15: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

UNIT: mm

Overall Dimension Drawing

3000 Series (40HP ~ 50HP)

WW1

DC

W2

C

H H1

Model H H1 W W1 W2 D C

S3000-300G/370P43A553 530 266 210 180 277.1 10

S3000-370G/450P43A

UNIT: mmW

W1D

C

W2

C

H H1

Model H H1 W W1 W2 D C

S3000-450G/550P43A652.6 630 2308.2 250 220 282 10

S3000-550G/750P43A

3000 Series (60HP ~ 75HP)

12

for more: efesotomasyon - sanch inverter

Page 16: Drive Solutions International - endüstriyel · PDF fileefficiently in accordance with the principle of satisfying our customers and creating ... (kVA) ) 0.6 1 .0 1.6 Rated output

International OfficePhone: +61 3 9795 2887Fax: +61 3 9795 7882Mobile: +61 419 424 246

Business CentreRoom 505, Fudan Technology Building11, Guo Tai Road, Shanghai, 200433 PRCPhone: +86 21 5169 6555Fax: +86 21 6140 0501

Factory Headquarters3, Zixin Road, Jiangnan High Tech ParkLicheng District, Quanzhou City, FujianProvince PRCPhone: +86 595 2898 3312Fax: +86 595 2898 3388

Contents subject to change without notice

Drive Solutions International

SISC2006

for more: efesotomasyon - sanch inverter