30
ENGINE G-Drive Series heavy duty diesel engine 4 cycle, water cooled, turbocharged / turbocharged & air to air charge cooled Direct injection Mechanic / electronic governor system 12 / 24 volt self-starter and charger alternator Changeable air, fuel and oil filter Tropical type radiator Flexible fuel pipe Oil discharge valve and extention pipe Industrial type silencer, exhaust spiral or compensator Maintenance free battery Engine jacket water heater (In automatic models) Maintenance and operating instructions ALTERNATOR Brushless, single bearing H Class insulation type IP21-23 Protection class Self exciter Automatic voltage regulator 2/3 Pitch factor windings 4 Poles AUTOMATIC CONTROL PANEL LCD display screen Hardware and materials needed Battery charger USB port & RS-485 output QUALITY STANDARD DIRECTIVES 2006/42/EC (Machinery Directive) 2014/30/EC (EMC Directive) 2014/35/EC (Low Voltage Directive) 2000/14/EC (Noise Emition Directive) CANOPY / CONTAINER Modular type sound-proof canopy / container Easy installation type without welding canopy Epoxy and polyester powder painted canopy Canopy designed for easy maintenance Locakable doors on both sides of canopy Emergency stop button Transparent panel inspection window PROTECTION & ALARMS High water temperature Low oil pressure High & low engine speed Low radiator water level Over current load High & low genset voltage Start / stop failure OPTIONAL EQUIPMENTS Charge ampmeter Circuit breakers (In automatic models) Residental / Critical type silencer Sound-proof canopy or container Mobile trailer and truck installation Synchronization panel for 2-32 gensets 3 pole / 4 pole automatic transfer panel (A.T.S.) Fuel and oil heater Anticondensation heater Fuel automation systems Different IP and Insulation class alternator PMG INTERNATIONAL QUALITY STANDARD EN12601, EN60204, EN12100, EN61000, EN55011 TS ISO 8528, TS ISO 3744, TS ISO 3746, TS ISO 13857 EN60034, EN55014, ISO 3046, BS5000, IEC 60034 VDE 0530, BSE 4999, EN60335, IBC 2015:EC8 2004 10 kVA - 22 kVA Easy maintenance canopy design Refilling from the outside of the canopy Canopy made of galvanized steel Warning system for decreasing fuel with electronic fuel level sender Series Diesel Generator Sets

10 kVA - 22 kVA

  • Upload
    others

  • View
    31

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 10 kVA - 22 kVA

ENGINE• G-Drive Series heavy duty diesel engine• 4 cycle, water cooled, turbocharged / turbocharged &

air to air charge cooled• Direct injection• Mechanic / electronic governor system• 12 / 24 volt self-starter and charger alternator• Changeable air, fuel and oil filter• Tropical type radiator• Flexible fuel pipe• Oil discharge valve and extention pipe• Industrial type silencer, exhaust spiral or compensator• Maintenance free battery• Engine jacket water heater (In automatic models)• Maintenance and operating instructions

ALTERNATOR• Brushless, single bearing• H Class insulation type• IP21-23 Protection class• Self exciter• Automatic voltage regulator• 2/3 Pitch factor windings• 4 Poles

AUTOMATIC CONTROL PANEL• LCD display screen• Hardware and materials needed• Battery charger• USB port & RS-485 output

QUALITY STANDARD DIRECTIVES• 2006/42/EC (Machinery Directive)• 2014/30/EC (EMC Directive)• 2014/35/EC (Low Voltage Directive)• 2000/14/EC (Noise Emition Directive)

CANOPY / CONTAINER• Modular type sound-proof canopy / container• Easy installation type without welding canopy• Epoxy and polyester powder painted canopy• Canopy designed for easy maintenance• Locakable doors on both sides of canopy• Emergency stop button• Transparent panel inspection window

PROTECTION & ALARMS• High water temperature • Low oil pressure• High & low engine speed • Low radiator water level• Over current load• High & low genset voltage• Start / stop failure

OPTIONAL EQUIPMENTS• Charge ampmeter• Circuit breakers (In automatic models)• Residental / Critical type silencer• Sound-proof canopy or container• Mobile trailer and truck installation• Synchronization panel for 2-32 gensets• 3 pole / 4 pole automatic transfer panel (A.T.S.)• Fuel and oil heater• Anticondensation heater• Fuel automation systems• Different IP and Insulation class alternator• PMG

INTERNATIONAL QUALITY STANDARD• EN12601, EN60204, EN12100, EN61000, EN55011• TS ISO 8528, TS ISO 3744, TS ISO 3746, TS ISO 13857• EN60034, EN55014, ISO 3046, BS5000, IEC 60034• VDE 0530, BSE 4999, EN60335, IBC 2015:EC8 2004

10 kVA - 22 kVA

Easy maintenance canopy design

Refilling from the outside of the canopy

Canopy made of galvanized steel

Warning system for decreasing fuel with

electronic fuel level sender

Series Diesel Generator Sets

Page 2: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0010 N PR XX 0015 N PR XX 0022

10

8

9

7,2

900 x 2100 x 1310

515

900 x 1750 x 1145

395

PERKINS

403A - 11G1

9,2

8,4

1500

4

1,131

3 IN LINE

77 x 81

23:1

3,00

2,30

1,70

4,9

5,2

92

14,5

11,6

13

10,5

900 x 2100 x 1310

525

900 x 1750 x 1235

405

PERKINS

403A - 15G1

13,2

12

1500

4

1,496

3 IN LINE

84 x 90

22,5 :1

3,70

2,80

2,00

6

6

92

22,3

17,8

20,3

16,2

900 x 2100 x 1310

595

900 x 1750 x 1285

480

PERKINS

404A - 22G1

20,3

18,4

1500

4

2,216

4 IN LINE

84 x 100

23,3 : 1

5,30

4,00

2,90

10,6

7

92

MECHANIC

NATURAL

INDIRECT INJECTION

WATER

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 3: 10 kVA - 22 kVA

ENGINE• G-Drive Series heavy duty diesel engine• 4 cycle, water cooled, turbocharged / turbocharged &

air to air charge cooled• Direct injection• Mechanic / electronic governor system• 12 / 24 volt self-starter and charger alternator• Changeable air, fuel and oil filter• Tropical type radiator• Flexible fuel pipe• Oil discharge valve and extention pipe• Industrial type silencer, exhaust spiral or compensator• Maintenance free battery• Engine jacket water heater (In automatic models)• Maintenance and operating instructions

ALTERNATOR• Brushless, single bearing• H Class insulation type• IP21-23 Protection class• Self exciter• Automatic voltage regulator• 2/3 Pitch factor windings• 4 Poles

AUTOMATIC CONTROL PANEL• LCD display screen• Hardware and materials needed• Battery charger• USB port & RS-485 output

QUALITY STANDARD DIRECTIVES• 2006/42/EC (Machinery Directive)• 2014/30/EC (EMC Directive)• 2014/35/EC (Low Voltage Directive)• 2000/14/EC (Noise Emition Directive)

CANOPY / CONTAINER• Modular type sound-proof canopy / container• Easy installation type without welding canopy• Epoxy and polyester powder painted canopy• Canopy designed for easy maintenance• Locakable doors on both sides of canopy• Emergency stop button• Transparent panel inspection window

PROTECTION & ALARMS• High water temperature • Low oil pressure• High & low engine speed • Low radiator water level• Over current load• High & low genset voltage• Start / stop failure

OPTIONAL EQUIPMENTS• Charge ampmeter• Circuit breakers (In automatic models)• Residental / Critical type silencer• Sound-proof canopy or container• Mobile trailer and truck installation• Synchronization panel for 2-32 gensets• 3 pole / 4 pole automatic transfer panel (A.T.S.)• Fuel and oil heater• Anticondensation heater• Fuel automation systems• Different IP and Insulation class alternator• PMG

INTERNATIONAL QUALITY STANDARD• EN12601, EN60204, EN12100, EN61000, EN55011• TS ISO 8528, TS ISO 3744, TS ISO 3746, TS ISO 13857• EN60034, EN55014, ISO 3046, BS5000, IEC 60034• VDE 0530, BSE 4999, EN60335, IBC 2015:EC8 2004

10 kVA - 2500 kVA

Easy maintenance canopy design

Refilling from the outside of the canopy

Canopy made of galvanized steel

Warning system for decreasing fuel with

electronic fuel level sender

Series Diesel Generator Sets

Page 4: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0010 N PR XX 0015 N PR XX 0022

10

8

9

7,2

900 x 2100 x 1310

515

900 x 1750 x 1145

395

PERKINS

403A - 11G1

9,2

8,4

1500

4

1,131

3 IN LINE

77 x 81

23:1

3,00

2,30

1,70

4,9

5,2

92

14,5

11,6

13

10,5

900 x 2100 x 1310

525

900 x 1750 x 1235

405

PERKINS

403A - 15G1

13,2

12

1500

4

1,496

3 IN LINE

84 x 90

22,5 :1

3,70

2,80

2,00

6

6

92

22,3

17,8

20,3

16,2

900 x 2100 x 1310

595

900 x 1750 x 1285

480

PERKINS

404A - 22G1

20,3

18,4

1500

4

2,216

4 IN LINE

84 x 100

23,3 : 1

5,30

4,00

2,90

10,6

7

92

MECHANIC

NATURAL

INDIRECT INJECTION

WATER

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 5: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0033 N PR XX 0050 N PR XX 0066

MECHANIC

NATURAL

MECHANIC/ ELECTRONIC

TURBOCHARGED

DIRECT INJECTION

WATER

33

26,4

30

24

1000 x 2450 x 1610

920

1000 x 2050 x 1400

725

PERKINS

1103A - 33G

30,4

27,7

1500

4

3,3

3 IN LINE

105 x 127

19,25 : 1

50

40

45

36

1000 x 2450 x 1610

970

1000 x 2050 x 1400

775

PERKINS

1103A - 33TG1

45,6

41,3

1500

4

3,3

3 IN LINE

105 x 127

17,25 : 1

66

52,8

60

48

1000 x 2450 x 1610

1085

1000 x 2050 x 1400

890

PERKINS

1103A - 33TG2

59,3

53,8

1500

4

3,3

3 IN LINE

105 x 127

17,25 : 1

7,20

5,61

4,06

8,3

10,2

132

10,80

8,23

5,83

7,9

10,2

132

13,9

10,4

7,2

7,9

10,2

132

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 6: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0072 N PR XX 088 N PR XX 0112

MECHANIC/ ELECTRONIC MECHANIC ELECTRONIC

TURBOCHARGED TURBOCHARGED -AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

72

57,6

65

52

1000 x 2880 x 1610

1180

1000 x 2400 x 1390

960

PERKINS

1104A - 44TG1

64,3

58,4

1500

4

4,4

4 IN LINE

105 x 127

17,25 : 1

14,80

11,20

8,00

8

13

180

88

70,4

80

64

1000 x 2880 x 1610

1230

1000 x 2400 x 1390

1010

PERKINS

1104A - 44TG2

79,1

71,9

1500

4

4,4

4 IN LINE

105 x 127

17,25 : 1

18,70

14,00

9,70

8

13

180

112

89,6

101,4

81,1

1000 x 2880 x 1610

1350

1000 x 2400 x 1390

1130

PERKINS

1104C - 44TAG2

99,5

90,1

1500

4

4,4

4 IN LINE

105 x 127

18,2:1

22,60

17,10

11,20

8

12,6

180

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 7: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0150 N PR XX 0165 N PR XX 0200

MECHANIC

TURBOCHARGED TURBOCHARGED -AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

150

120

135

108

1050 x 3180 x 1870

1750

1050 x 2700 x 1650

1505

PERKINS

1106A - 70TG1

131,4

118,3

1500

4

7,01

6 IN LINE

105 x 135

18,2 : 1

30,2

22,70

15,90

18,0

21

280

165

132

150

120

1050 x 3180 x 1870

1750

1050 x 2700 x 1650

1505

PERKINS

1106A - 70TAG2

144,1

131

1500

4

7,01

6 IN LINE

105 x 135

16:01

33,40

24,70

16,40

16,5

21

280

200

160

180

144

1050 x 3580 x 1870

1940

1050 x 3100 x 1650

1680

PERKINS

1106A - 70TAG3

175,2

157,7

1500

4

7,01

6 IN LINE

105 x 135

16:01

41,2

30,9

20,6

16,5

21

380

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 8: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0220 N PR XX 0250 N PR XX 0275

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

220

176

200

160

1050 x 3580 x 1870

1940

1050 x 3100 x 1650

1680

PERKINS

1106A - 70TAG4

191,3

173,9

1500

4

7,01

6 IN LINE

105 x 135

16:01

45,8

34,3

22,9

16,5

21

380

250

200

230

184

1150 x 3820 x 2460

2500

1150 x 3340 x 1900

2200

PERKINS

1506A - E88TAG2

223

201

1500

4

8,8

6 IN LINE

112 x 149

16,1 : 1

48,6

35,7

23,5

41

29,6

585

275

220

250

200

1150 x 3820 x 2460

2515

1150 x 3340 x 1900

2220

PERKINS

1506A - E88TAG3

245

223

1500

4

8,8

6 IN LINE

112 x 149

16,1 : 1

55,5

41,6

28,9

41

29,6

585

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 9: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0300 N PR XX 0330 N PR XX 0400

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

300

240

275

220

1150 x 3820 x 2460

2520

1150 x 3340 x 1900

2220

PERKINS

1506A-E88TAG4

267

244

1500

4

8,8

6 IN LINE

112 x 149

16,1 : 1

60,2

45,8

31,6

41

33,2

585

330

264

300

240

1150 x 3820 x 2460

2670

1150 x 3340 x 1900

2370

PERKINS

1506A-E88TAG5

293

267

1500

4

8,8

6 IN LINE

112 x 149

16,1 :1

64,9

48,2

33,00

41

33,2

585

400

320

350

280

1500 x 4400 x 2660

3520

1500 x 3600 x 2200

3010

PERKINS

2206A - E13TAG2

349

305

1500

4

12,5

6 IN LINE

130 x 157

16,3 : 1

71,00

54,00

37,00

40

51,40

970

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 10: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0450 N PR XX 0500 N PR XX 0550

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

450

360

400

320

1500 x 4400 x 2660

3610

1500 x 3600 x 2200

3105

PERKINS

2206A - E13TAG3

392

349

1500

4

12,5

6 IN LINE

130 x 157

16,3 : 1

81,00

62,00

42,00

40

51,40

970

500

400

455

364

1500 x 4400 x 2660

3815

1500 x 3600 x 2200

3310

PERKINS

2506A - E15TAG1

435

396

1500

4

15,2

6 IN LINE

137 x 171

16,0:1

95,00

72,00

50,00

62

58

970

550

440

500

400

1500 x 4400 x 2660

3850

1500 x 3600 x 2200

3345

PERKINS

2506A - E15TAG2

478

435

1500

4

15,2

6 IN LINE

137 x 171

16,0:1

100,00

76,00

53,00

62

58

970

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 11: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0630 N PR XX 0650 N PR XX 0700

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

630

504

591

472,8

1700 x 4400 x 2750

4620

1700 x 3600 x 2250

4070

PERKINS

2806A - E18TAG1A

574

522

1500

4

18,1

6 IN LINE

145 x 183

14,5 : 1

123,00

90,00

61,00

62

61

1100

650

520

591

472,8

1700 x 4400 x 2750

4620

1700 x 3600 x 2250

4070

PERKINS

2806A - E18TAG1A

574

522

1500

4

18,1

6 IN LINE

145 x 183

14,5 : 1

123,00

90,00

61,00

62

61

1100

700

560

650

520

1700 x 4400 x 2750

4760

1700 x 3600 x 2250

4210

PERKINS

2806A - E18TAG2

609

565

1500

4

18,1

6 IN LINE

145 x 183

14,5 : 1

132,00

97,00

66,00

62

61

1100

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 12: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

CONTAINER DIMENSION (W x L x H) mm

CONTAINER WEIGHT kg

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0825 N PR XX 0900 N PR XX 1002

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

825

660

750

600

1900 x 5250 x 3330

6525

1900 x 5000 x 2395

5180

1900 x 5290 x 3640

8100

PERKINS

4006 - 23TAG2A

695

632

1500

4

22,921

6 IN LINE

160 x 190

13,6 : 1

161,00

122,00

83,00

113,4

105

1400

900

720

800

640

1900 x 5250 x 3330

6835

1900 x 5000 x 2395

5490

1900 x 5290 x 3640

8100

PERKINS

4006 - 23TAG3A

760

679

1500

4

22,921

6 IN LINE

160 x 190

13,6 : 1

172,00

130,00

90,00

113,4

105

1400

1002

802

911

729

2200 x 5550 x 3300

9635

2200 x 5300 x 2640

8090

2200 x 5300 x 3390

9700

PERKINS

4008TAG1A

855

778

1500

4

30,561

8 IN LINE

160 x 190

13,6 : 1

195,00

143,00

98,00

153

149

2000

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 13: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

CONTAINER DIMENSION (W x L x H) mm

CONTAINER WEIGHT kg

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 1125 N PR XX 1250 N PR XX 1375

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

1375

1100

1250

1000

N/A

N/A

2200 x 5350 x 2750

8080

N/A

N/A

PERKINS

4012 - 46TAG0A

1158

1053

1500

4

45,842

12 - 60˚ V

160 x 190

13:1

259,00

199,00

139,00

177

210

2500

1125

900

1022

818

2200 x 5550 x 3300

9995

2200 x 5300 x 2640

8450

2200 x 5300 x 3390

9800

PERKINS

4008TAG2A

958

872

1500

4

30,561

8 IN LINE

160 x 190

13,6 : 1

215,00

162,00

111,00

153

149

2000

1250

1000

1125

900

2200 x 5550 x 3300

10025

2200 x 5300 x 2640

8480

2200 x 5300 x 3390

9800

PERKINS

4008-30TAG3

1055

947

1500

4

30,561

8 IN LINE

160 x 190

13,1 : 1

244,00

188,00

120,00

153

140

2000

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 14: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

CONTAINER DIMENSION (W x L x H) mm

CONTAINER WEIGHT kg

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 1385 N PR XX 1500 N PR XX 1656

ELECTRONIC

TURBOCHARGED -AIR TO WATER CHARGE COOLED TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

1385

1108

1250

1000

N/A

N/A

2200 x 5350 x 2750

8080

N/A

N/A

PERKINS

4012 - 46TWG2A

1166

1055

1500

4

45,842

12 - 60˚ V

160 x 190

13,6:1

258,00

196,00

143,00

177

210

2500

4

1500

1200

1350

1080

N/A

N/A

2200 x 5350 x 2750

8745

N/A

N/A

PERKINS

4012 - 46TAG1A

1263

1148

1500

45,842

12 - 60˚ V

160 x 190

13:1

281,00

212,00

154,00

177

210

2500

1656

1325

1505

1204

N/A

N/A

2200 x 5350 x 2750

8745

N/A

N/A

PERKINS

4012 - 46TAG2A

1395

1267

1500

4

45,842

12 - 60˚ V

160 x 190

13,6:1

301,00

237,00

162,00

177

210

2500

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 15: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

CONTAINER DIMENSION (W x L x H) mm

CONTAINER WEIGHT kg

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 1880 N PR XX 2028 N PR XX 2250

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED TURBOCHARGED -AIR TO WATER CHARGE COOLED

DIRECT INJECTION

WATER

1880

1504

1710

1368

N/A

N/A

2200 x 5350 x 2750

9075

N/A

N/A

PERKINS

4012 - 46TAG3A

1583

1440

1500

4

45,842

12 - 60˚ V

160 x 190

13,6:1

370,00

275,00

187,00

177

210

3000

2028

1622

1844

1476

N/A

N/A

2200 x 6000 x 3140

10760

N/A

N/A

PERKINS

4016TAG1A

1690

1537

1500

4

61,123

16 - 60˚ V

160 x 190

13,6 : 1

383,00

277,00

185,00

237,2

316

3000

2250

1800

2000

1600

N/A

N/A

2200 x 6000 x 3140

10800

N/A

N/A

PERKINS

4016 - 61TRG2

1895

1684

1500

4

61,123

16 - 60˚ V

160 x 190

13,6 : 1

422,00

318,00

216,00

237,2

252

3500

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 16: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

CONTAINER DIMENSION (W x L x H) mm

CONTAINER WEIGHT kg

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

ELECTRONIC

TURBOCHARGED -AIR TO WATER CHARGE COOLED

TURBOCHARGED -AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

N PR XX 2264

2264

1811,2

2058

1646,4

N/A

N/A

2200 x 6000 x 3140

10800

N/A

N/A

PERKINS

4016TAG2A

1886

1715

1500

4

61,123

16 - 60˚ V

160 x 190

13,6 : 1

434,00

327,00

222,00

237,2

316

3500

N PR XX 2500

2500

2000

2250

1800

N/A

N/A

2200 x 6000 x 3140

11190

N/A

N/A

PERKINS

4016 - 61TRG3

2083

1875

1500

4

61,123

16 - 60˚ V

160 x 190

13,6:1

470,00

344,00

234,00

237,2

270

4000

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 17: 10 kVA - 22 kVA

ENGINE• G-Drive Series heavy duty diesel engine• 4 cycle, water cooled, turbocharged / turbocharged &

air to air charge cooled• Direct injection• Mechanic / electronic governor system• 12 / 24 volt self-starter and charger alternator• Changeable air, fuel and oil filter• Tropical type radiator• Flexible fuel pipe• Oil discharge valve and extention pipe• Industrial type silencer, exhaust spiral or compensator• Maintenance free battery• Engine jacket water heater (In automatic models)• Maintenance and operating instructions

ALTERNATOR• Brushless, single bearing• H Class insulation type• IP21-23 Protection class• Self exciter• Automatic voltage regulator• 2/3 Pitch factor windings• 4 Poles

AUTOMATIC CONTROL PANEL• LCD display screen• Hardware and materials needed• Battery charger• USB port & RS-485 output

QUALITY STANDARD DIRECTIVES• 2006/42/EC (Machinery Directive)• 2014/30/EC (EMC Directive)• 2014/35/EC (Low Voltage Directive)• 2000/14/EC (Noise Emition Directive)

CANOPY / CONTAINER• Modular type sound-proof canopy / container• Easy installation type without welding canopy• Epoxy and polyester powder painted canopy• Canopy designed for easy maintenance• Locakable doors on both sides of canopy• Emergency stop button• Transparent panel inspection window

PROTECTION & ALARMS• High water temperature • Low oil pressure• High & low engine speed • Low radiator water level• Over current load• High & low genset voltage• Start / stop failure

OPTIONAL EQUIPMENTS• Charge ampmeter• Circuit breakers (In automatic models)• Residental / Critical type silencer• Sound-proof canopy or container• Mobile trailer and truck installation• Synchronization panel for 2-32 gensets• 3 pole / 4 pole automatic transfer panel (A.T.S.)• Fuel and oil heater• Anticondensation heater• Fuel automation systems• Different IP and Insulation class alternator• PMG

INTERNATIONAL QUALITY STANDARD• EN12601, EN60204, EN12100, EN61000, EN55011• TS ISO 8528, TS ISO 3744, TS ISO 3746, TS ISO 13857• EN60034, EN55014, ISO 3046, BS5000, IEC 60034• VDE 0530, BSE 4999, EN60335, IBC 2015:EC8 2004

33 kVA - 66 kVA

Easy maintenance canopy design

Refilling from the outside of the canopy

Canopy made of galvanized steel

Warning system for decreasing fuel with

electronic fuel level sender

Series Diesel Generator Sets

Page 18: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0033 N PR XX 0050 N PR XX 0066

MECHANIC

NATURAL

MECHANIC/ ELECTRONIC

TURBOCHARGED

DIRECT INJECTION

WATER

33

26,4

30

24

1000 x 2450 x 1610

920

1000 x 2050 x 1400

725

PERKINS

1103A - 33G

30,4

27,7

1500

4

3,3

3 IN LINE

105 x 127

19,25 : 1

50

40

45

36

1000 x 2450 x 1610

970

1000 x 2050 x 1400

775

PERKINS

1103A - 33TG1

45,6

41,3

1500

4

3,3

3 IN LINE

105 x 127

17,25 : 1

66

52,8

60

48

1000 x 2450 x 1610

1085

1000 x 2050 x 1400

890

PERKINS

1103A - 33TG2

59,3

53,8

1500

4

3,3

3 IN LINE

105 x 127

17,25 : 1

7,20

5,61

4,06

8,3

10,2

132

10,80

8,23

5,83

7,9

10,2

132

13,9

10,4

7,2

7,9

10,2

132

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 19: 10 kVA - 22 kVA

ENGINE• G-Drive Series heavy duty diesel engine• 4 cycle, water cooled, turbocharged / turbocharged &

air to air charge cooled• Direct injection• Mechanic / electronic governor system• 12 / 24 volt self-starter and charger alternator• Changeable air, fuel and oil filter• Tropical type radiator• Flexible fuel pipe• Oil discharge valve and extention pipe• Industrial type silencer, exhaust spiral or compensator• Maintenance free battery• Engine jacket water heater (In automatic models)• Maintenance and operating instructions

ALTERNATOR• Brushless, single bearing• H Class insulation type• IP21-23 Protection class• Self exciter• Automatic voltage regulator• 2/3 Pitch factor windings• 4 Poles

AUTOMATIC CONTROL PANEL• LCD display screen• Hardware and materials needed• Battery charger• USB port & RS-485 output

QUALITY STANDARD DIRECTIVES• 2006/42/EC (Machinery Directive)• 2014/30/EC (EMC Directive)• 2014/35/EC (Low Voltage Directive)• 2000/14/EC (Noise Emition Directive)

CANOPY / CONTAINER• Modular type sound-proof canopy / container• Easy installation type without welding canopy• Epoxy and polyester powder painted canopy• Canopy designed for easy maintenance• Locakable doors on both sides of canopy• Emergency stop button• Transparent panel inspection window

PROTECTION & ALARMS• High water temperature • Low oil pressure• High & low engine speed • Low radiator water level• Over current load• High & low genset voltage• Start / stop failure

OPTIONAL EQUIPMENTS• Charge ampmeter• Circuit breakers (In automatic models)• Residental / Critical type silencer• Sound-proof canopy or container• Mobile trailer and truck installation• Synchronization panel for 2-32 gensets• 3 pole / 4 pole automatic transfer panel (A.T.S.)• Fuel and oil heater• Anticondensation heater• Fuel automation systems• Different IP and Insulation class alternator• PMG

INTERNATIONAL QUALITY STANDARD• EN12601, EN60204, EN12100, EN61000, EN55011• TS ISO 8528, TS ISO 3744, TS ISO 3746, TS ISO 13857• EN60034, EN55014, ISO 3046, BS5000, IEC 60034• VDE 0530, BSE 4999, EN60335, IBC 2015:EC8 2004

72 kVA - 112 kVA

Easy maintenance canopy design

Refilling from the outside of the canopy

Canopy made of galvanized steel

Warning system for decreasing fuel with

electronic fuel level sender

Series Diesel Generator Sets

Page 20: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0072 N PR XX 088 N PR XX 0112

MECHANIC/ ELECTRONIC MECHANIC ELECTRONIC

TURBOCHARGED TURBOCHARGED -AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

72

57,6

65

52

1000 x 2880 x 1610

1180

1000 x 2400 x 1390

960

PERKINS

1104A - 44TG1

64,3

58,4

1500

4

4,4

4 IN LINE

105 x 127

17,25 : 1

14,80

11,20

8,00

8

13

180

88

70,4

80

64

1000 x 2880 x 1610

1230

1000 x 2400 x 1390

1010

PERKINS

1104A - 44TG2

79,1

71,9

1500

4

4,4

4 IN LINE

105 x 127

17,25 : 1

18,70

14,00

9,70

8

13

180

112

89,6

101,4

81,1

1000 x 2880 x 1610

1350

1000 x 2400 x 1390

1130

PERKINS

1104C - 44TAG2

99,5

90,1

1500

4

4,4

4 IN LINE

105 x 127

18,2:1

22,60

17,10

11,20

8

12,6

180

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 21: 10 kVA - 22 kVA

ENGINE• G-Drive Series heavy duty diesel engine• 4 cycle, water cooled, turbocharged / turbocharged &

air to air charge cooled• Direct injection• Mechanic / electronic governor system• 12 / 24 volt self-starter and charger alternator• Changeable air, fuel and oil filter• Tropical type radiator• Flexible fuel pipe• Oil discharge valve and extention pipe• Industrial type silencer, exhaust spiral or compensator• Maintenance free battery• Engine jacket water heater (In automatic models)• Maintenance and operating instructions

ALTERNATOR• Brushless, single bearing• H Class insulation type• IP21-23 Protection class• Self exciter• Automatic voltage regulator• 2/3 Pitch factor windings• 4 Poles

AUTOMATIC CONTROL PANEL• LCD display screen• Hardware and materials needed• Battery charger• USB port & RS-485 output

QUALITY STANDARD DIRECTIVES• 2006/42/EC (Machinery Directive)• 2014/30/EC (EMC Directive)• 2014/35/EC (Low Voltage Directive)• 2000/14/EC (Noise Emition Directive)

CANOPY / CONTAINER• Modular type sound-proof canopy / container• Easy installation type without welding canopy• Epoxy and polyester powder painted canopy• Canopy designed for easy maintenance• Locakable doors on both sides of canopy• Emergency stop button• Transparent panel inspection window

PROTECTION & ALARMS• High water temperature • Low oil pressure• High & low engine speed • Low radiator water level• Over current load• High & low genset voltage• Start / stop failure

OPTIONAL EQUIPMENTS• Charge ampmeter• Circuit breakers (In automatic models)• Residental / Critical type silencer• Sound-proof canopy or container• Mobile trailer and truck installation• Synchronization panel for 2-32 gensets• 3 pole / 4 pole automatic transfer panel (A.T.S.)• Fuel and oil heater• Anticondensation heater• Fuel automation systems• Different IP and Insulation class alternator• PMG

INTERNATIONAL QUALITY STANDARD• EN12601, EN60204, EN12100, EN61000, EN55011• TS ISO 8528, TS ISO 3744, TS ISO 3746, TS ISO 13857• EN60034, EN55014, ISO 3046, BS5000, IEC 60034• VDE 0530, BSE 4999, EN60335, IBC 2015:EC8 2004

150 kVA - 200 kVA

Easy maintenance canopy design

Refilling from the outside of the canopy

Canopy made of galvanized steel

Warning system for decreasing fuel with

electronic fuel level sender

Series Diesel Generator Sets

Page 22: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0150 N PR XX 0165 N PR XX 0200

MECHANIC

TURBOCHARGED TURBOCHARGED -AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

150

120

135

108

1050 x 3180 x 1870

1750

1050 x 2700 x 1650

1505

PERKINS

1106A - 70TG1

131,4

118,3

1500

4

7,01

6 IN LINE

105 x 135

18,2 : 1

30,2

22,70

15,90

18,0

21

280

165

132

150

120

1050 x 3180 x 1870

1750

1050 x 2700 x 1650

1505

PERKINS

1106A - 70TAG2

144,1

131

1500

4

7,01

6 IN LINE

105 x 135

16:01

33,40

24,70

16,40

16,5

21

280

200

160

180

144

1050 x 3580 x 1870

1940

1050 x 3100 x 1650

1680

PERKINS

1106A - 70TAG3

175,2

157,7

1500

4

7,01

6 IN LINE

105 x 135

16:01

41,2

30,9

20,6

16,5

21

380

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 23: 10 kVA - 22 kVA

ENGINE• G-Drive Series heavy duty diesel engine• 4 cycle, water cooled, turbocharged / turbocharged &

air to air charge cooled• Direct injection• Mechanic / electronic governor system• 12 / 24 volt self-starter and charger alternator• Changeable air, fuel and oil filter• Tropical type radiator• Flexible fuel pipe• Oil discharge valve and extention pipe• Industrial type silencer, exhaust spiral or compensator• Maintenance free battery• Engine jacket water heater (In automatic models)• Maintenance and operating instructions

ALTERNATOR• Brushless, single bearing• H Class insulation type• IP21-23 Protection class• Self exciter• Automatic voltage regulator• 2/3 Pitch factor windings• 4 Poles

AUTOMATIC CONTROL PANEL• LCD display screen• Hardware and materials needed• Battery charger• USB port & RS-485 output

QUALITY STANDARD DIRECTIVES• 2006/42/EC (Machinery Directive)• 2014/30/EC (EMC Directive)• 2014/35/EC (Low Voltage Directive)• 2000/14/EC (Noise Emition Directive)

CANOPY / CONTAINER• Modular type sound-proof canopy / container• Easy installation type without welding canopy• Epoxy and polyester powder painted canopy• Canopy designed for easy maintenance• Locakable doors on both sides of canopy• Emergency stop button• Transparent panel inspection window

PROTECTION & ALARMS• High water temperature • Low oil pressure• High & low engine speed • Low radiator water level• Over current load• High & low genset voltage• Start / stop failure

OPTIONAL EQUIPMENTS• Charge ampmeter• Circuit breakers (In automatic models)• Residental / Critical type silencer• Sound-proof canopy or container• Mobile trailer and truck installation• Synchronization panel for 2-32 gensets• 3 pole / 4 pole automatic transfer panel (A.T.S.)• Fuel and oil heater• Anticondensation heater• Fuel automation systems• Different IP and Insulation class alternator• PMG

INTERNATIONAL QUALITY STANDARD• EN12601, EN60204, EN12100, EN61000, EN55011• TS ISO 8528, TS ISO 3744, TS ISO 3746, TS ISO 13857• EN60034, EN55014, ISO 3046, BS5000, IEC 60034• VDE 0530, BSE 4999, EN60335, IBC 2015:EC8 2004

220 kVA - 275 kVA

Easy maintenance canopy design

Refilling from the outside of the canopy

Canopy made of galvanized steel

Warning system for decreasing fuel with

electronic fuel level sender

Series Diesel Generator Sets

Page 24: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0220 N PR XX 0250 N PR XX 0275

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

220

176

200

160

1050 x 3580 x 1870

1940

1050 x 3100 x 1650

1680

PERKINS

1106A - 70TAG4

191,3

173,9

1500

4

7,01

6 IN LINE

105 x 135

16:01

45,8

34,3

22,9

16,5

21

380

250

200

230

184

1150 x 3820 x 2460

2500

1150 x 3340 x 1900

2200

PERKINS

1506A - E88TAG2

223

201

1500

4

8,8

6 IN LINE

112 x 149

16,1 : 1

48,6

35,7

23,5

41

29,6

585

275

220

250

200

1150 x 3820 x 2460

2515

1150 x 3340 x 1900

2220

PERKINS

1506A - E88TAG3

245

223

1500

4

8,8

6 IN LINE

112 x 149

16,1 : 1

55,5

41,6

28,9

41

29,6

585

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 25: 10 kVA - 22 kVA

ENGINE• G-Drive Series heavy duty diesel engine• 4 cycle, water cooled, turbocharged / turbocharged &

air to air charge cooled• Direct injection• Mechanic / electronic governor system• 12 / 24 volt self-starter and charger alternator• Changeable air, fuel and oil filter• Tropical type radiator• Flexible fuel pipe• Oil discharge valve and extention pipe• Industrial type silencer, exhaust spiral or compensator• Maintenance free battery• Engine jacket water heater (In automatic models)• Maintenance and operating instructions

ALTERNATOR• Brushless, single bearing• H Class insulation type• IP21-23 Protection class• Self exciter• Automatic voltage regulator• 2/3 Pitch factor windings• 4 Poles

AUTOMATIC CONTROL PANEL• LCD display screen• Hardware and materials needed• Battery charger• USB port & RS-485 output

QUALITY STANDARD DIRECTIVES• 2006/42/EC (Machinery Directive)• 2014/30/EC (EMC Directive)• 2014/35/EC (Low Voltage Directive)• 2000/14/EC (Noise Emition Directive)

CANOPY / CONTAINER• Modular type sound-proof canopy / container• Easy installation type without welding canopy• Epoxy and polyester powder painted canopy• Canopy designed for easy maintenance• Locakable doors on both sides of canopy• Emergency stop button• Transparent panel inspection window

PROTECTION & ALARMS• High water temperature • Low oil pressure• High & low engine speed • Low radiator water level• Over current load• High & low genset voltage• Start / stop failure

OPTIONAL EQUIPMENTS• Charge ampmeter• Circuit breakers (In automatic models)• Residental / Critical type silencer• Sound-proof canopy or container• Mobile trailer and truck installation• Synchronization panel for 2-32 gensets• 3 pole / 4 pole automatic transfer panel (A.T.S.)• Fuel and oil heater• Anticondensation heater• Fuel automation systems• Different IP and Insulation class alternator• PMG

INTERNATIONAL QUALITY STANDARD• EN12601, EN60204, EN12100, EN61000, EN55011• TS ISO 8528, TS ISO 3744, TS ISO 3746, TS ISO 13857• EN60034, EN55014, ISO 3046, BS5000, IEC 60034• VDE 0530, BSE 4999, EN60335, IBC 2015:EC8 2004

300 kVA - 400 kVA

Easy maintenance canopy design

Refilling from the outside of the canopy

Canopy made of galvanized steel

Warning system for decreasing fuel with

electronic fuel level sender

Series Diesel Generator Sets

Page 26: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0300 N PR XX 0330 N PR XX 0400

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

300

240

275

220

1150 x 3820 x 2460

2520

1150 x 3340 x 1900

2220

PERKINS

1506A-E88TAG4

267

244

1500

4

8,8

6 IN LINE

112 x 149

16,1 : 1

60,2

45,8

31,6

41

33,2

585

330

264

300

240

1150 x 3820 x 2460

2670

1150 x 3340 x 1900

2370

PERKINS

1506A-E88TAG5

293

267

1500

4

8,8

6 IN LINE

112 x 149

16,1 :1

64,9

48,2

33,00

41

33,2

585

400

320

350

280

1500 x 4400 x 2660

3520

1500 x 3600 x 2200

3010

PERKINS

2206A - E13TAG2

349

305

1500

4

12,5

6 IN LINE

130 x 157

16,3 : 1

71,00

54,00

37,00

40

51,40

970

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 27: 10 kVA - 22 kVA

ENGINE• G-Drive Series heavy duty diesel engine• 4 cycle, water cooled, turbocharged / turbocharged &

air to air charge cooled• Direct injection• Mechanic / electronic governor system• 12 / 24 volt self-starter and charger alternator• Changeable air, fuel and oil filter• Tropical type radiator• Flexible fuel pipe• Oil discharge valve and extention pipe• Industrial type silencer, exhaust spiral or compensator• Maintenance free battery• Engine jacket water heater (In automatic models)• Maintenance and operating instructions

ALTERNATOR• Brushless, single bearing• H Class insulation type• IP21-23 Protection class• Self exciter• Automatic voltage regulator• 2/3 Pitch factor windings• 4 Poles

AUTOMATIC CONTROL PANEL• LCD display screen• Hardware and materials needed• Battery charger• USB port & RS-485 output

QUALITY STANDARD DIRECTIVES• 2006/42/EC (Machinery Directive)• 2014/30/EC (EMC Directive)• 2014/35/EC (Low Voltage Directive)• 2000/14/EC (Noise Emition Directive)

CANOPY / CONTAINER• Modular type sound-proof canopy / container• Easy installation type without welding canopy• Epoxy and polyester powder painted canopy• Canopy designed for easy maintenance• Locakable doors on both sides of canopy• Emergency stop button• Transparent panel inspection window

PROTECTION & ALARMS• High water temperature • Low oil pressure• High & low engine speed • Low radiator water level• Over current load• High & low genset voltage• Start / stop failure

OPTIONAL EQUIPMENTS• Charge ampmeter• Circuit breakers (In automatic models)• Residental / Critical type silencer• Sound-proof canopy or container• Mobile trailer and truck installation• Synchronization panel for 2-32 gensets• 3 pole / 4 pole automatic transfer panel (A.T.S.)• Fuel and oil heater• Anticondensation heater• Fuel automation systems• Different IP and Insulation class alternator• PMG

INTERNATIONAL QUALITY STANDARD• EN12601, EN60204, EN12100, EN61000, EN55011• TS ISO 8528, TS ISO 3744, TS ISO 3746, TS ISO 13857• EN60034, EN55014, ISO 3046, BS5000, IEC 60034• VDE 0530, BSE 4999, EN60335, IBC 2015:EC8 2004

450 kVA - 550 kVA

Easy maintenance canopy design

Refilling from the outside of the canopy

Canopy made of galvanized steel

Warning system for decreasing fuel with

electronic fuel level sender

Series Diesel Generator Sets

Page 28: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0450 N PR XX 0500 N PR XX 0550

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

450

360

400

320

1500 x 4400 x 2660

3610

1500 x 3600 x 2200

3105

PERKINS

2206A - E13TAG3

392

349

1500

4

12,5

6 IN LINE

130 x 157

16,3 : 1

81,00

62,00

42,00

40

51,40

970

500

400

455

364

1500 x 4400 x 2660

3815

1500 x 3600 x 2200

3310

PERKINS

2506A - E15TAG1

435

396

1500

4

15,2

6 IN LINE

137 x 171

16,0:1

95,00

72,00

50,00

62

58

970

550

440

500

400

1500 x 4400 x 2660

3850

1500 x 3600 x 2200

3345

PERKINS

2506A - E15TAG2

478

435

1500

4

15,2

6 IN LINE

137 x 171

16,0:1

100,00

76,00

53,00

62

58

970

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets

Page 29: 10 kVA - 22 kVA

ENGINE• G-Drive Series heavy duty diesel engine• 4 cycle, water cooled, turbocharged / turbocharged &

air to air charge cooled• Direct injection• Mechanic / electronic governor system• 12 / 24 volt self-starter and charger alternator• Changeable air, fuel and oil filter• Tropical type radiator• Flexible fuel pipe• Oil discharge valve and extention pipe• Industrial type silencer, exhaust spiral or compensator• Maintenance free battery• Engine jacket water heater (In automatic models)• Maintenance and operating instructions

ALTERNATOR• Brushless, single bearing• H Class insulation type• IP21-23 Protection class• Self exciter• Automatic voltage regulator• 2/3 Pitch factor windings• 4 Poles

AUTOMATIC CONTROL PANEL• LCD display screen• Hardware and materials needed• Battery charger• USB port & RS-485 output

QUALITY STANDARD DIRECTIVES• 2006/42/EC (Machinery Directive)• 2014/30/EC (EMC Directive)• 2014/35/EC (Low Voltage Directive)• 2000/14/EC (Noise Emition Directive)

CANOPY / CONTAINER• Modular type sound-proof canopy / container• Easy installation type without welding canopy• Epoxy and polyester powder painted canopy• Canopy designed for easy maintenance• Locakable doors on both sides of canopy• Emergency stop button• Transparent panel inspection window

PROTECTION & ALARMS• High water temperature • Low oil pressure• High & low engine speed • Low radiator water level• Over current load• High & low genset voltage• Start / stop failure

OPTIONAL EQUIPMENTS• Charge ampmeter• Circuit breakers (In automatic models)• Residental / Critical type silencer• Sound-proof canopy or container• Mobile trailer and truck installation• Synchronization panel for 2-32 gensets• 3 pole / 4 pole automatic transfer panel (A.T.S.)• Fuel and oil heater• Anticondensation heater• Fuel automation systems• Different IP and Insulation class alternator• PMG

INTERNATIONAL QUALITY STANDARD• EN12601, EN60204, EN12100, EN61000, EN55011• TS ISO 8528, TS ISO 3744, TS ISO 3746, TS ISO 13857• EN60034, EN55014, ISO 3046, BS5000, IEC 60034• VDE 0530, BSE 4999, EN60335, IBC 2015:EC8 2004

630 kVA - 700 kVA

Easy maintenance canopy design

Refilling from the outside of the canopy

Canopy made of galvanized steel

Warning system for decreasing fuel with

electronic fuel level sender

Series Diesel Generator Sets

Page 30: 10 kVA - 22 kVA

MODEL

GROU

P

GEN-SET POWER

STAND BY kVA

kW

PRIME kVA

kW

CANOPY DIMENSION (W x L x H) mm

CANOPY WEIGHT kg

OPEN DIMENSION (W x L x H) mm

OPEN WEIGHT

ENGI

NE

BRAND

TYPE

POWER STAND BY kW

PRIME kW

SPEED (rpm)

CYCLE

DISPLACEMENT (lt)

NUMBER OF CYLNDERS

BORE x STROKE (mm x mm)

COMPRESSION RATIO

GOVERNOR TYPE

INDUCTION

COMBUSTION SYSTEM

COOLING SYSTEM

FUEL CONSUMPTION lt / h

%100 PRIME POWER

%75 PRIME POWER

%50 PRIME POWER

TOTAL LUBRICATION SYSTEM CAPACITY (lt)

TOTAL COOLANT CAPACITY (lt)

FUEL TANK CAPACITY (lt)

N PR XX 0630 N PR XX 0650 N PR XX 0700

ELECTRONIC

TURBOCHARGED - AIR TO AIR CHARGE COOLED

DIRECT INJECTION

WATER

630

504

591

472,8

1700 x 4400 x 2750

4620

1700 x 3600 x 2250

4070

PERKINS

2806A - E18TAG1A

574

522

1500

4

18,1

6 IN LINE

145 x 183

14,5 : 1

123,00

90,00

61,00

62

61

1100

650

520

591

472,8

1700 x 4400 x 2750

4620

1700 x 3600 x 2250

4070

PERKINS

2806A - E18TAG1A

574

522

1500

4

18,1

6 IN LINE

145 x 183

14,5 : 1

123,00

90,00

61,00

62

61

1100

700

560

650

520

1700 x 4400 x 2750

4760

1700 x 3600 x 2250

4210

PERKINS

2806A - E18TAG2

609

565

1500

4

18,1

6 IN LINE

145 x 183

14,5 : 1

132,00

97,00

66,00

62

61

1100

Npower reserves the right to make changes in model, technical specifications, color, equipment & accessories without prior notice. All rights reserved.

Series Diesel Generator Sets