View
213
Download
1
Tags:
Embed Size (px)
Citation preview
Doctorant: Limin Meng Directrice: Annie Klisnick
Etude expérimentale et simulation numérique des lasers XUV transitoires en mode ASE et injecté
Experimental study and numerical simulations of transient XUV lasers in ASE and seeded mode
1 What is XUV laser?
XUV (Extreme ultraviolet) laser is the coherent radiation whose wavelength is in the X-ray range(3nm-50nm).
XUV
y
x
z
Target(Ti, Mo, Ag….)
Pre-Laser
Plasma
Pump laser
HOH
2 production of transient XUV laser
1 ) ionization-pre pulse irradiate in normal direction,
2 ) Pump-interval hundreds ps, grazing incidence pumping (GRIP)
3a ) production of ASE XUV laser-Amplitude Spontaneous Emission (ASE mode) 3b ) production of seeded XUV laser-high order harmonics (HOH) seed
ASE XRL
Seeded XUV
3 My topic---measure the temporal coherence and the spectral line width of the XUV laser
In many application, we need short pulse duration. Such as production of plasma, and the detection of fast process.
The duration of current XUV lasers is limited to ~1ps, due to a very narrow bandwidth (Δλ/λ 10∼ -5)
Our goal is to find strategies to enlarge the bandwidth and reach duration of a few 100 fs
4 How to measure the bandwith of the XUV laser —the variable path difference interferometer
Interferometer—view outside
Lc is the coherent length that we can calculate directly from the experiment results.
Interference field
Interferometer—principle shown
mobile dihedron
fixed tilted dihedron
XUV Laser Beam
Z
CCD
cc Lc 112
4 the work I have done 1 --Measurement of the Temporal Coherence of a
Seeded GRIP Transient Mo XUV Laser
Far field footprint
Detected fringesExperiment performed at CSU (USA)Results are submitted to Optics Letters
Main conclusion: the coherence length is about 400um, corresponding to a linewidth of about 3mÅ; spectral narrowing when the length of the plasma amplifier is increased.—agreement with simulation
-100 0 100 200 300 400 500 600 700 8000,0
0,2
0,4
0,6
0,8
1,0
Vis
ibil
ity
Path difference (um)
average
exponential fitting
the work I have done 2–- Measurement of the Temporal Coherence and the
duration of a ASE Transient Mo XUV Laser In the second year, I have done a new experiment, which is performed at LASERIX! We are now analysing the data. Some example of the images and the preliminary results are shown below
XUV laser duration vs pump pulse duration
0
1
2
3
4
5
6
7
0 2 4 6 8 10
pump pulse duration(ps)
XU
V la
se
r p
uls
e
du
rati
on
(ps
)
0.75 ps
8 ps4 ps
1.5 ps
5 What I Will do
The goal is to define the effect of several
parameters to the linewidth:
atomic number the electron density
----Preparing new experiment at Laserix
----compare the results with numerical simulation
Thank you for your attention!