12
Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on work from: France: POMME B. Bonin et al. Nucl. Inst. Methods A288,389 (1990) V.P. Ladygin et al., Nucl. Inst. Methods A404, 129 (1998) Japan: DPOL Y. Satou, private communication Emphasizes elastic scattering Carbon target Want highest efficiency and vector spin dependence

Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

Embed Size (px)

DESCRIPTION

POMME layout tracks from magnetic spectrometer trigger scintillators final scintillator wire chambers Carbon target Iron absorber Changes for EDM application: eliminate wire chambers (high rates) and segment final scintillator adjust carbon thickness to maximize efficiency (FOM) adjust iron thickness to favor elastic over breakup events

Citation preview

Page 1: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

Deuteron polarimetry from 1.0 to 1.5 GeV/cEd Stephenson, IUCFEDM discussionApril 14, 2006

Based on work from:

France: POMMEB. Bonin et al. Nucl. Inst. Methods A288,389 (1990)V.P. Ladygin et al., Nucl. Inst. Methods A404, 129 (1998)

Japan: DPOLY. Satou, private communication

Emphasizes elastic scatteringCarbon target

Want highest efficiency and vector spin dependence

Page 2: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

A typical experimental layout contains:

beamdirection

scatteringplane

y

x

z

leftdetector

β

rightdetector

target

(φ=0)

A polarization of the beam (p) causes a difference in the ratesfor scattering to the left according to:

]2cossin)(23

sincossin)(3)1cos3()(8

1

cossin)(31[)()(

222

212

20

11

Tp

TpTp

iTp

T

TT

Vunp

analyzing power(determined by nuclear

effects in scattering)governs spin sensitivity

unpolarized cross section(determined by nuclear

effects in scattering)governs efficiency

φ

θ

left and right detectorsuseful for vector polarization

031

101

0

11

ffffpffp

T

V

Page 3: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

POMME layout

tracks frommagnetic spectrometer

triggerscintillators

finalscintillator

wire chambersCarbontarget

Ironabsorber

Changes for EDM application:eliminate wire chambers (high rates) and segment final scintillatoradjust carbon thickness to maximize efficiency (FOM)adjust iron thickness to favor elastic over breakup events

Page 4: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

Up

Down

Right

Left

Carbontarget

Ironabsorber

Segmentedscintillator

Functionalpolarimeterelements(must runcontinuously)

RLRL

LR

Left-right asymmetrycarries EDM information.

UDUD

DU

Down-up asymmetrycarries information ong-2 precession.

Carbon target is small.

Detailed design awaits decisionon bringing beam to polarimeter: slow extraction into second beam extract using jet in ring onto annular target tune beam onto annular target

Angle range:4° - 15°

Page 5: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

Rate considerations for feedback on phase (g-2 vs. sync.)

Compare two inputs: BPM in dispersed regiondown-up asymmetry

Bin asymmetry data into about 10 bins through one oscillation.

Maximum asymmetry: 3.03.06.07.13 11 iTpV

Events needed: 2)(1

N for δφ = 1%, N = 105

Then: load ring with 1011 deuteronlose half to polarimeter in 1000 s, target rate = 5 x 107 /swith polarimeter efficiency at 6%, detector sees 3 x 106 /s or 3 x 105 /s/bin

Can measure phase to 1% about 3 times per second.

Example:

Page 6: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

Sample data:

Bonin Satou

Note differences in peak analyzing power !!!Bonin did not eliminate breakup as well.Satou did at the expense of efficiency.

Page 7: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

270-MeV deuteron elasticscattering – RIKEN[data example](errors not shown)

NEW DEFINITION OFFIGURE OF MERIT

1)()( 11 iTFOM

Optimize here:favor larger analyzing power,leverage against systematics

Optimize here:favor statistical precision

FIRST TRADE-OFF

At smaller anglesCoulomb andmultiple scatteringdominate, makingcross section largeand analyzing power zero.

Page 8: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

The trade-off at high and low energies:

700 MeV

At the higher energies, FOM andanalyzing power peak together.There is no trade-off.

200 MeV

FOM has two comparablepeaks, so two options areequally good statistically.Thus higher analyzing power is favored.

Page 9: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

Before optimizing the FOM as a function of energy, consider two other energy dependencies:

The cross section is falling.

More energy allows thicker targets.Dots = French dataLine = curve used here

Page 10: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

The SOLID dots and lines follow theFORWARD peak in the FOM curve.

The open/dashed dots and lines followthe analyzing power peak (where thereis enough data to use).

The AVERAGES shown here integrateover some angle range that covers therelevant feature in FOM or iT11.

Satou gets even larger analyzingpowers by cutting out more protonsand losing “efficiency”. The FOMis down about 30% from the opendots.

SECOND TRADE-OFF:

Page 11: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

Polarimeter Systematic ErrorsWhat other sources arisefor a left/right asymmetry?

1 Displacement / angle errorsdetectors

θ

angle shift

θ

x

position shift

Usual remedy: measure on both sides (L/R) flip initial spin use cross ratio formula

RL

RL

CCCCr

rrpA

11

spin

detector

left/right efficiencydifferences cancel

+/ luminositydifferences cancel

Page 12: Deuteron polarimetry from 1.0 to 1.5 GeV/c Ed Stephenson, IUCF EDM discussion April 14, 2006 Based on…

Errors that are second-order in θ and u=p++p

22

22223

2

')1("'21

1

AA

AAu

AAumeas

logarithmic derivatives of the analyzing poweras a function of scattering angle

We are helped by the small size of the asymmetry and the expected time dependence.

Sizes of logarithmic derivatives need to be evaluated for some polarimeter acceptance geometry.