The three prime considerations that dictate kitchen design are:– Service requirement: Consider the service the

kitchen has to provide - for instance, the numbers being served, is it an la carte menu, plated service, self-service, cafeteria-style, etc?

– Space available: Is the space allocated sufficient to fit in the equipment required?

– Budget: Always have an accurate idea of spend available.

Page 3: Designing a commercial kitchen

Good Design Workflow1. Delivery2. Storage3. Food preparation4. Cooking5. Holding6. Food service area7. Wash-up8. Waste disposal

Page 4: Designing a commercial kitchen

Risk assessment

• Always carry out a risk assessment of any design to identify any shortfalls –

• for instance, the need to keep the food preparation area separate from the rest of the kitchen to negate the risk of cross-contamination.

Page 5: Designing a commercial kitchen

Delivery

• Ensure goods vehicles have adequate access to the premises, providing direct deliveries to the catering area.

• Provide adequate space to allow a goods check-in area before entering the kitchen.

Page 6: Designing a commercial kitchen

Storage

• Where possible, bulk storage should be close to the goods-in area so there's no need for delivery personnel to enter the kitchen and food preparation area.

• Never underestimate the need to allow adequate space for dry, chilled and frozen goods. Many suppliers have minimum drop requirements.

Page 7: Designing a commercial kitchen

Preparation• Position main preparation between bulk storage

and the cooking process, to ensure the correct flow pattern.

• Different processes should be segregated – i.e. raw meat and fish separate from prepared foods. If necessary, consider chilled preparation areas for high-risk food environments.

Page 8: Designing a commercial kitchen

Preparation• In smaller establishments where segregation

is not possible, stringent regimes must be employed to ensure segregation of processes, so that utensils and tables are suitably sanitised between processes.

• In addition, consider adequate refrigerated storage for prepared food.

• Provide adequate prep sinks, separate pot-wash sinks and hand-wash facilities.

Page 9: Designing a commercial kitchen

Cooking• When selecting cooking equipment, consider the

requirements of the menu and the ability of the staff using the equipment.

• Although state-of-the-art equipment such as programmable combi-ovens, pressure bratt pans and computerised deep-fat fryers may be nice to have, they may not always be appropriate for the style and content of some menus.

Page 10: Designing a commercial kitchen

Cooking• Ensure the flow of the cooking suite suits the style

of service, with fast-cook equipment such as fryers, salamanders and griddles nearest to the point of service and bulk cooking kit such as bratt pans, convection ovens and boiling pans further away.

• Conversely, never underestimate the benefits that hi-tech equipment can provide, in terms of cost control, and energy and labour savings.

• Workflows and safety should be the prime drivers in the layout of a professional kitchen.

Page 11: Designing a commercial kitchen

Cooking• Simple things include ensuring there's a set-

down space next to deep-fat fryers, never sitting a fryer at the end of a run, and always allowing a minimum of 900mm corridor to the front of any cooking equipment, although 1,200mm is ideal.

• Consideration should also be given to the mechanical and electrical services available. Sometimes it's not possible to get gas into a building, or you may be restricted by the size of the incoming electrical supply.

Page 12: Designing a commercial kitchen

Holding• Some food production systems require

extensive food holding systems

• The holding area is usually near to the food service area

• Food must be kept at the correct temperature

Page 13: Designing a commercial kitchen

Food Service Area• The space requirement for service is often

underestimated, particularly by architects. Whether the operation is waited service or tray-line style, you can minimise queuing by the provision of multi pick-up and service points. Consider adequate space for hot and cold holding of prepared food ready for service.

• If it's a large site, counters may need to be replenished several times during a service period. In an la carte restaurant, allow sufficient space for plating up and hot pass. Where possible, locate the service point close to the final cooking process to avoid double handling.

Page 14: Designing a commercial kitchen

Wash-up• Nearly always undersized by space planners, the

dishwashing operation is key to the success of any catering establishment. If it fails through inefficient planning, the restaurant cannot function.

• To determine the space required, the capacity of dishwasher and the amount of ancillary sorting space, calculate the number of crockery, cutlery and hollow-ware items (don't forget trays) to be used during a service period.

Page 15: Designing a commercial kitchen

Wash-up• All reputable dishwasher manufacturers can

help you with this calculation and provide you with the correct size system and machine.

• Remember to allow sufficient space for the storage of clean items and the disposal of rubbish, ensuring the two are segregated to avoid cross-contamination.

Page 16: Designing a commercial kitchen

Wash-up• Location is paramount to the efficient

management of the space. Ideally it should be close to both the restaurant and service area to avoid double handling.

• The amount of steam and moist air produced is often underestimated. If possible, consult a ventilation engineer.

Page 17: Designing a commercial kitchen

Refuse• Always allow for a clearly defined route

for dirty dishes that won't conflict with preparation and service areas. Consider the location of an outside refuse bay, well away from the kitchen entrance.

• Staff facilities• Ensure that appropriately located and

sized facilities for staff changing and locker areas and staff toilets are available near the kitchen.

Page 18: Designing a commercial kitchen

Environmental• Consider energy efficiency of all

equipment, as fuel costs are now higher than ever. Also, consider volumes of water used and research your product; many major manufacturers use energy efficiency as their USPs.

• Consider any "green" policies, allow for recycling of bottles, aluminium, plastic and paper. If possible, have a recycling area.

Page 19: Designing a commercial kitchen

Environmental• Ensure correct ventilation and air replacement are

available in all areas. Consult an engineer to ensure you comply with the minimum requirements of the local authority's clean air policy. 

• Ensure lighting provides at least the minimum requirement of 500 lux at worktop height.

• Invite your local EHO to view your plans and pass comment. It's always best to get them on your side at the outset.

Page 20: Designing a commercial kitchen

Building fabric• Ensure floors (non-slip), walls and

ceilings can be cleaned and maintained easily.