    1.1 Spatial Requirements

    A well planned kitchen should:

    Provide adequate storage for raw materials.

    Provide adequate space for food being prepared.

    Provide adequate space food awaiting service.

    Provide adequate storage for equipment, utensils, crockery and cutlery.

    Be efficient and effective in terms of movement of staff, equipment, materials and waste

    Provide an area for checking in stock.

    Janitorial store for kitchen, with janitorial sink in place and chemical store.

    To maintain effective movement through spaces, the area per person according to use of the

    equipment has been established

    by the Building Act 1984 / Workplace (Health, Safety and Welfare) Regulations 1992. It is

    recommended that in a kitchen each

    person needs 10m2.

    1.2 Work Flow

    The premises shall be designed so that there is a continuous progression of food from

    delivery to storage, through topreparation and the finished product, with no cross over to avoid cross contamination.

    1.2.1 Food Delivery or Receiving

    This includes the receiving of purchased goods, which involves: handling, checking, recording

    or storage.

    Some of these functions may be combined or not needed depending on the size of the

    kitchen.

  • 8/10/2019 Commercial Kitchen Library Study

    4/26

    1.2.2 Storage

    The amount of storage space and the type of storage will depend on:

    The size of the kitchen.

    Menu.

    The volume of business.

    Delivery frequency. The length of storage.

    The type of storage (frozen, refrigerated or dry).

    Storage of meats, poultry and fish should be taken into consideration when designing the

    kitchen and kept separate

    from dry foods, vegetables, fruit and pastry.

    1.2.3 Preparation and Cooking

    The main preparation areas in food premises are for:

    Meat preparation.

    Poultry preparation.

    Fish preparation.

    Vegetable preparation. Pastry/dessert preparation.

    All food preparation areas should be separate from the cooking area.

    1.2.4 Clean Crockery

    Storage for clean crockery should be close to the washing up facility to minimise excess

    movement around the kitchen

    and ideally in a separate room due to the air pollution in a kitchen.

  • 8/10/2019 Commercial Kitchen Library Study

    5/26

    1.2.5 Food Service

    The type of service (a la carte, fast food, caf or banquet) will direct how the serving function is

    performed. The most

    common service is plate service, which requires pick-up points next to the cooking area. The

    pick-up point arrangement

    should have a method to keep the dishes warm/cold.

    There should be a separate pick-up point for chilled food such as desserts to be held in a

    refrigerated cabinet. The

    pick-up point arrangement is critical for an efficient in and out flow of waiter traffic. It is

    essential to design kitchen

    flow of service/waiters traffic in the kitchen layout.

    1.2.6 Waste Food and Dirty Crockery

    The dish washing area positioning is vital to the successful operation of any kitchen. The design

    of the dish washing

    area should have a large drop off area. This area should have the facility to cope with the waste

    from plates. The following is a suggested list of possible cleaning/storing methods and

    equipment: Stainless steel racking for pots and pans. Open for ease of cleaning.

    Stainless steel racking for plates in separate enclosed area.

    Cutlery storage.

    Enclosed storage for mops, chemical and janitorial sink. Different mops for different areas.

    Adequate sinks. When positioning sinks, drainage should be addressed e.g. Sinks should be in

    line, in order to reduce the number of Grease Traps required.

  • 8/10/2019 Commercial Kitchen Library Study

    6/26

    Pre-rinse hose on dirty sink.

    Extraction system.

    Waste disposal bin (differing bins for recyclables).

    Waste Management System.

    HACCP - Regulation (EC) No. 852/2004 on the hygiene of foodstuffs.

    Food, Oil & Grease are by products of the kitchen and create drainage problems in kitchens.These substances create

    major problems for treatment plants. The best method of controlling this is at source. This

    should be addressed at

    planning stage to prevent problems from water companies, environmental agencies and

    public health inspectors.

    1.3 Provisions for Adequate Space

    Space shall be provided on the premises for staff to handle food and perform other activities

    that are part of the food

    business.

    Space should be provided for:

    Staff changing room. Food preparation and service.

    Separation of raw food preparation from cooked food preparation and other ready-to-eat

    food preparation areas.

    Washing and sanitizing operations for utensils and equipment.

    Separation of food storage and handling areas from areas for chemical storage, toilets, waste

    storage, office areas and other areas used for activities that could contaminate food.

  • 8/10/2019 Commercial Kitchen Library Study

    7/26

    SUGGESTED COMMERCIAL KITCHEN LAYOUT PLAN

  • 8/10/2019 Commercial Kitchen Library Study

    8/26

    2.1 Temperature Measuring Devices

    Temperatures must be taken and recorded A temperature measuring device needs to be

    readily accessible and must accurately measure the temperature of

    food to +/- 1C.

    The temperature of cold food should be maintained at 8 Celsius, or below.This is to minimise the growth of infectious or toxigenic micro-organismst

    The temperature of hot food should be maintained at 63 Celsius or above.

    2.2 Food Handling

    Staff must wash hands as they move from different areas in the kitchen e.g. preparation

    to cooking. This will help

    reduce cross contamination. Prepared meats, poultry, fish and vegetables must be

    refrigerated until needed and held

    in a refrigerated under counter unit in the cooking/prep area.

    Ideally

    Use colour coded chopping boards and knives for raw and ready-to-eat food.

    Wash your hands before preparing food and after.

    Keep raw and ready-to-eat food apart at all times.

    Any staff suffering from diarrhea / vomiting within hours must not be allowed into the

    kitchen area under any

    circumstance.

  • 8/10/2019 Commercial Kitchen Library Study

    9/26

    3.1 Water supply

    Water supply is required for the following:

    Drinking. Cooking.

    Ice making.

    Cleaning.

    Sanitizing.

    Personal hygiene.

    Fire suppression systems (fire hydrants, hose reels and sprinkler systems).

    Separate non-potable water supplies are often used for fire suppression systems e.g.

    recycled rainwater.

    Hot water must be stored at a minimum of 60C to prevent growth of bacteria such as

    Legionella. (See page 24).Water pressure must be adequate to meet all the demands of the commercial kitchen.

    Non-potable water: Water that is not suitable for human consumption (grey water).

  • 8/10/2019 Commercial Kitchen Library Study

    10/26

  • 8/10/2019 Commercial Kitchen Library Study

    11/26

  • 8/10/2019 Commercial Kitchen Library Study

    12/26

    In a kitchen with three work centersthe sum of

    the three traveled distances should total no morethan 26' with no single leg of the triangle

    measuring less than 4 feet nor more than 9 feet.

    A major appliance and its surrounding landing/work

    area form a work center. The distances between the

    three primary work centers (cooking surface, clean-

    up/prep primary sink, and refrigeration storage) form a

    work triangle.

    When the kitchen plan includes more than threeprimary appliance/work centers, each additional travel

    distance to another appliance/work center should

    measure no less than 4' nor more than 9'.

    Each leg is measured from the center-front of the

    appliance/sink.

    No work triangle leg may intersect an island/peninsulaor other obstacle by more than 12".

    No major traffic patterns should cross through

    the basic work triangle.

    WORK TRIANGLE

  • 8/10/2019 Commercial Kitchen Library Study

    13/26

    The width of a work aisle should be at least 42 for one cook and at least 48 for

    multiple cooks. Measure between the counter frontage, tall cabinets and/or

    appliances.

    ADA/ANSI Guidelines:A clear floor space of at least 30 by 48 should be

    provided at each kitchen appliance. Clear floor

    spaces can overlap. (ANSI A 117.1 305.3, 804.6.1).

    (ANSI A 117.1 404.2.3.1)

    In a U-shaped kitchen, plan a minimum clearance of

    60 between opposing arms. (ANSI A117.1 804.2.2,1003.12.1.2).

    Include a wheelchair turning space with a diameter

    of at least 60, which can include knee* and toe*

    clearances. (ANSI A117.1 304.3.1).

    A wheelchair turning space could utilize a T-shaped

    clear space, which is a 60 square with two 12 widex 24 deep areas removed from the corners of the

    square. This leaves a minimum 36 wide base and

    two 36 wide arms. T-shaped wheelchair turning

    spaces can include knee and toe clearances. (ANSI

    A117.1 304.3.2).

    WORK AISLE

  • 8/10/2019 Commercial Kitchen Library Study

    14/26

    The width of a walkway should be at least 36.

    If two walkways are perpendicular to each

    other, one walkway should be at least 42

    wide.

    In planning a Universal Access Kitchen...

    Knee clearance must be a minimum 30 wide (36 to use as part of the T-turn) and

    maintain a 27 clear space under the cabinet, counter or sink for a depth of 8. The

    next 3 of depth may slope down to a height of 9, with a clear space of at least 17

    extending beneath the element. (ANSI 306.3).

    Toe clearance space under a cabinet or appliance is between the floor and 9 above

    the floor. Where toe clearance is required as part of a clear floor space, the toe

    clearance should extend 17 minimum beneath the element. (ANSI A117.1 306.2).

    WALKWAYS

  • 8/10/2019 Commercial Kitchen Library Study

    15/26

    Include at least:

    15 of landing area on the handle side of the refrigerator, or

    15 of landing area on either side of a side-by-side refrigerator, or

    15 of landing area which is no more than 48across from the front of the refrigerator, or

    15 of landing area above or adjacent to any undercounter style refrigeration appliance.

    ADA/ANSI Guidelines:A clear

    floor space of 30 x 48 should

    be positioned for a parallel

    approach to the

    refrigerator/freezer with thecenterline of the clear floor

    space offset 24 maximum from

    the centerline of the appliance.

    (ANSI A 117.1 804.6.6,

    1003.12.6.6)

    REFRIGERATOR LANDING AREA

  • 8/10/2019 Commercial Kitchen Library Study

    16/26

    Include a minimum of 12 of landing area on one side of a cooking surface and 15 on the

    other side.

    Note A: The 12 and 15 landing areas must be at the same height as the cooking surface.

    Note B:For safety reasons, in an island or peninsula situation, the countertop should alsoextend a minimum of 9 behind the cooking surface if the counter height is the same as

    the surface-cooking appliance.

    Note C: For an enclosed configuration, a reduction of clearances shall be in accordance

    with the appliance manufacturers instructions or per local codes. (This may not provide

    adequate landing area.)

    ADA/ANSI Guidelines:

    When a forward-approach clear

    floor space is provided at the

    cooktop, it should provide knee and

    toe clearance and the underside of

    the cooktop should be insulated or

    otherwise configured to prevent

    burns, abrasions, or electric shock.

    (ANSI 1002.12.6.4)

    The location of cooktop controls

    should not require reaching acrossburners. (ANSI 1003.12.6.4)

    COOK SURFACE LANDING AREA

  • 8/10/2019 Commercial Kitchen Library Study

    17/26

    Guideline:Provide a correctly sized, ducted ventilation system for all cooking surface

    appliances. The recommended minimum is 150 cubic feet of air per minute (cfm).

    Code Requirement:Manufacturers specifications must be followed. (IRC G 2407.1, IRC G 2447.1).

    The minimum required exhaust rate for a ducted hood is 100 cfm and must be ducted to

    the outside. (IRC M 1507.3).

    Make-up air may need to be provided. Refer to local codes. (IRC G 2407.4).

    Universal Design

    Guideline:Ventilation

    controls should be

    placed 15 44 abovethe floor, operable with

    minimal effort, easy to

    read and with minimal

    noise pollution.

    COOKING SURFACE VENTILATION

  • 8/10/2019 Commercial Kitchen Library Study

    18/26

    ADA/ANSI Guidelines:

    Operable parts should be operable with

    one hand and not require tight grasping,pinching or twisting of the wrist. The

    force required to activate operable parts

    should be 5 pounds maximum. (ANSI

    A117.1 309.4).

    Where a forward or side reach is

    unobstructed, the high reach should be48 maximum and the low reach should

    be 15 minimum above the floor.(ANSI

    A117.1 308.2.1 and 308.3.1).

    Where a forward or side reach is

    obstructed by a 20 25 deep counter,

    the high reach should be 44 maximum.(ANSI A117.1 308.2.2)

  • 8/10/2019 Commercial Kitchen Library Study

    19/26

    12.1 Emergency Signage

    12.1.1 Exit Signs

    Exit signs are required to direct people to exit doors in the case of an emergency.

    12.1.2 Fire Emergency SignageIt is necessary in a commercial kitchen to provide signage that tells

    Signs detailing the emergency evacuation plan for the business. Staff should be made

    aware of where emergency

    evacuation procedures are written down.

    Instructional signs adjacent to fire extinguishers, fire blankets and fire hose reels detailing

    their correct use.

    12.1.3 First Aid Signage

    Signs should be installed to clearly mark the location of first aid kits.

    12.2 Hygiene Signage

    12.2.1 Personal Hygiene Signage

    Personal hygiene of staff is important to prevent contamination of food.

    12.2.2 Kitchen Hygiene Signage

    Posters should be displayed that detail the procedures necessary to keep the kitchen clean

    and hygienic..

    12.2.3 Check Lists

    To keep track of hygiene and cleanliness issues, a checklist of procedures is recommended.

    The checklist should providea brief description of what is required.

    SIGNAGE

  • 8/10/2019 Commercial Kitchen Library Study

    20/26

    13.1 Storage of Personal Items`

    Staff should be provided with adequate and secure storage for clothing and personal

    belongings.

    13.2 Change RoomsStaff should be provided with dedicated change rooms, particularly when they are required to

    wear uniforms.

    13.3 Toilets

    It is essential that staff have access to toilets.

    For a small business located in a shopping centre, use of the centres public toilets may be

    adequate.

    For larger businesses, staff may share the toilet facilities provided for patrons

    Where more than 10 staff are employed, separate male and female toilets should be provided.

    Toilets must not open directly into kitchens or food storage areas and should be accessed via

    airlocks with self-closing doors. toilets must be adequately ventilated in accordance with the

    Building Act 1984.

    13.4 Storage of Office Materials

    Office materials and paperwork should be stored in a room designated for office use

    13.5 Wash Hand Basins

    Staff must have access to wash hand basins / Quadwash facilities after visits to the

    toilets/smoking areas(contamination from lighters / cigarette packets).

    Wash hand basins must be located where staff move from one area to another e.g. from preparea to cooking area.

    STAFF AMENITIES

  • 8/10/2019 Commercial Kitchen Library Study

    21/26

    Basic fire precautions are:

    All areas should be kept clean from dust, dirt and oil to limit fire damage.

    All cooking and high-risk appliances should be watched when in use.

    14.1 Emergency Procedures

    All kitchens must have a written emergency evacuation plan in place.

    14.1.1 Emergency Manuals

    All manuals for emergency devices, solutions to dangerous situations and other emergency

    instructions etc. should be kept in the same place. They must be clearly labeled, well organizedand easy to understand.

    14.2 Emergency Devices

    Emergency devices should be dispersed around the kitchen, not all in the same area.

    Emergency equipment should be serviced at least once a year.

    14.2.1 Fire Extinguishers

    The most common cause of serious fires in commercial kitchens is the over-heating of deepfryer oil.

    It is recommended that all extinguishers / blankets used in the kitchen are suitable for hot oil

    fires.

    How many extinguishers?

    The number of extinguishers is dependent on the size of the kitchen.

    FIRE SAFETY

  • 8/10/2019 Commercial Kitchen Library Study

    22/26

    Location

    They should be in a main thoroughfare, preferably along the exit route.

    They need to be easy to access in a hurry.

    They should be 100mm high off the floor; the top of the extinguisher should be 1200mm from

    the floor.

    For electrical fires the extinguisher must be closer than 40m from the appliances. For cooking oils and fats the extinguishers must be placed between 2 and 20m from the risk. In

    a

    commercial kitchen 20m is too far away, it is safer to keep them within 10m.

  • 8/10/2019 Commercial Kitchen Library Study

    23/26

    SOME LAYOUT PLANS OF COMMERCIAL KITCHENS

    REFERENCE

  • 8/10/2019 Commercial Kitchen Library Study

    24/26

    REFERENCE:

    http://scullmeister.blogspot.in/2014/05/tiny-commercial-kitchen-layout.html

  • 8/10/2019 Commercial Kitchen Library Study

    25/26

    http://www.viahouse.com/2013/07/commercial-kitchen-design-of-dirties/extravagant-modern-style-commercial-kitchen-design-spacious-room-design/

    REFERENCE

  • 8/10/2019 Commercial Kitchen Library Study

    26/26

    REFERENCES

    http://www.alulinegms.com/sitedata/files/kitchen_design_guide.pdf

    http://starcraftcustombuilders.com/kitchen.design.rules.htm#.VFMZKvmSxz4

    https://www.safework.sa.gov.au/contentPages/docs/hospSafeDesignComKitc

    hen.pdf

    http://en.wikipedia.org/wiki/Kitchen_work_triangle

    ADA/ANSI STANDARDS

    http://www.alulinegms.com/sitedata/files/kitchen_design_guide.pdfhttp://starcraftcustombuilders.com/kitchen.design.rules.htmhttps://www.safework.sa.gov.au/contentPages/docs/hospSafeDesignComKitchen.pdfhttps://www.safework.sa.gov.au/contentPages/docs/hospSafeDesignComKitchen.pdfhttp://en.wikipedia.org/wiki/Kitchen_work_trianglehttp://en.wikipedia.org/wiki/Kitchen_work_trianglehttp://en.wikipedia.org/wiki/Kitchen_work_trianglehttps://www.safework.sa.gov.au/contentPages/docs/hospSafeDesignComKitchen.pdfhttps://www.safework.sa.gov.au/contentPages/docs/hospSafeDesignComKitchen.pdfhttps://www.safework.sa.gov.au/contentPages/docs/hospSafeDesignComKitchen.pdfhttp://starcraftcustombuilders.com/kitchen.design.rules.htmhttp://starcraftcustombuilders.com/kitchen.design.rules.htmhttp://www.alulinegms.com/sitedata/files/kitchen_design_guide.pdfhttp://www.alulinegms.com/sitedata/files/kitchen_design_guide.pdf