58
Data Sheet D184S073U02 Electromagnetic Flowmeter FSM4000 Pos: 1 /Titelblätter / Copyright/DB/Durchfluss/FSM4000 @ 3\mod_1157697105687_3101.doc @ 40413 Function - Electromagnetic flowmeters can be used to accurately measure the flowrate of liquids, slurries, pastes and sludges with an electrical conductivity of at least 20 μS/cm (opt. 5/0.5 μS/cm). Applications - The system is specially designed to measure liquids in the pulp & paper and food & beverage industries. It can be used to measure fast changing processes, two phase liquids, continuous and pulsating flows (piston pump application). Benefits - Digital signal processing (DSP) and zero stability ensure long-term stability and accuracy in both flow directions. - Enhanced diagnostic functions and monitoring of coil and electrode circuits as well as magnetic field for increased operational stability. Verification via fingerprint. Key features - Flowmeter sensor designed acc. to PED Directive 97/23 EC - Meter size DN 1 (1/25") ... DN 40 (4") - Accuracy < ± 0.5% of rate (> DN 2) - Fluid temperature -40 … 130 °C (-40 ... 266 °F) (opt. 180 °C [356 °F]) - Hygienic certification: 3A, EHEDG - Liners, PFA, PTFE, hard or soft rubber - Standardized installation lengths for DIN, ASME B16.5 or JIS B2210-10K flanges - Power supply AC/DC P RO F I BUS PROCESS FIELD BUS ® The all-purpose flowmeter for conductive fluids Pos: 2 /Inhaltsverzeichnis/Inhaltsverzeichnis für alle Dokumente @ 0\mod_1138710310890_3101.doc @ 3129 Contents

Data Sheet Electromagnetic Flowmeter D184S073U02 FSM4000...2004/02/07  · - Standardized installation lengths for DIN, ASME B16.5 or JIS B2210-10K flanges - Power supply AC/DC P R

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

  • Data Sheet D184S073U02

    Electromagnetic FlowmeterFSM4000

    Pos: 1 /Titelblätter / Copyright/DB/Durchfluss/FSM4000 @ 3\mod_1157697105687_3101.doc @ 40413

    Function - Electromagnetic flowmeters can be used to

    accurately measure the flowrate of liquids, slurries, pastes and sludges with an electrical conductivity of at least 20 µS/cm (opt. 5/0.5 µS/cm).

    Applications - The system is specially designed to measure

    liquids in the pulp & paper and food & beverage industries. It can be used to measure fast changing processes, two phase liquids, continuous and pulsating flows (piston pump application).

    Benefits - Digital signal processing (DSP) and zero stability

    ensure long-term stability and accuracy in both flow directions.

    - Enhanced diagnostic functions and monitoring of coil and electrode circuits as well as magnetic field for increased operational stability. Verification via fingerprint.

    Key features - Flowmeter sensor designed acc. to PED Directive

    97/23 EC - Meter size DN 1 (1/25") ... DN 40 (4") - Accuracy < ± 0.5% of rate (> DN 2) - Fluid temperature -40 … 130 °C (-40 ... 266 °F)

    (opt. 180 °C [356 °F]) - Hygienic certification: 3A, EHEDG - Liners, PFA, PTFE, hard or soft rubber - Standardized installation lengths for DIN, ASME

    B16.5 or JIS B2210-10K flanges - Power supply AC/DC

    P R O F I

    B U S

    PROCESS FIELD BUS

    ®

    The all-purpose flowmeterfor conductive fluids

    Pos: 2 /Inhaltsverzeichnis/Inhaltsverzeichnis für alle Dokumente @ 0\mod_1138710310890_3101.doc @ 3129 Contents

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    2

    Contents 1 Overview of flowmeter sensor and transmitter designs .................................................................................3 2 General information ............................................................................................................................................4

    2.1 Measuring accuracy .......................................................................................................................................4 2.2 Grounding.......................................................................................................................................................4 2.3 Installation Requirements...............................................................................................................................4 2.4 Flowmeter Sizes, Pressure Ratings, Flow Range..........................................................................................7 2.5 Flowmeter Sizes, Pressure Ratings, Flow Range..........................................................................................7 2.6 Flowrate nomograph ......................................................................................................................................8

    3 Model SE41F ......................................................................................................................................................10 3.1 Technical data ..............................................................................................................................................10 3.2 Dimensional drawings ..................................................................................................................................13 3.3 Ordering information.....................................................................................................................................19

    4 Model SE21_ ......................................................................................................................................................26 4.1 Technical data ..............................................................................................................................................26 4.2 Dimensional drawings ..................................................................................................................................28 4.3 Ordering information.....................................................................................................................................39

    5 Mounting accessories.......................................................................................................................................42 6 Transmitter.........................................................................................................................................................43

    6.1 Technical data ..............................................................................................................................................43 6.2 Inputs/outputs...............................................................................................................................................45 6.3 Digital communication ..................................................................................................................................45 6.4 Terminal connection diagrams .....................................................................................................................47 6.5 Connection examples for peripherals (incl. HART)......................................................................................51 6.6 Dimensional drawings ..................................................................................................................................54 6.7 Ordering information.....................................................................................................................................55

    7 Order information: Wafer accessories (table H) ............................................................................................56 8 Order information: Flowmeter sensor simulator FXC 4000 ..........................................................................57

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    3

    Pos: 3 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Übersichten/Übersicht Aufnehmer und Messumformer @ 3\mod_1157623996796_3101.doc @ 39718

    1 Overview of flowmeter sensor and transmitter designs

    Housing Material Alumin. Hous. Series 4000 Stainless Steel Housing Series 2000

    G00211

    DN 3 ... 40 (1/10 . . 1 1/2").

    DN 50 ... 10 0 (2 ... 4")0

    G00210DN 3 ... 100 (1/10 ... 4")

    G00209

    DN 3 ... 40 (1/10 ... 1 1/2”)

    DN 50 ... 100 (2 ... 4”)

    G00208

    1) 2)

    3) 4)

    DN 3 ... 40(1/10 . . 1 1/2").

    DN 50 ... 100(2 ... 4")

    Fixed Flange Fixed Flange Wafer design Variable Connections

    Flowmeter sensor Model Number SE41F SE21F SE21W SE21_* Accuracy 0.5 % of rate (> DN 2) DN PN DN PN DN PN DN PN *

    Wafer design - - 3 … 50 65 … 100 10 … 40 10 … 16

    Flange DIN 2501/EN 1092-1 3 ... 1000 10 ... 40 3 … 100 10 … 40 - - Flange ASME B16.5 / B16.47 JIS B2210-10K

    1/10 ... 40" 1/10 … 12“

    CL 150 CL 300

    1/10“ … 4“

    CL150 … CL300/JIS

    1/10“ … 2“3“ … 4“

    CL300/JIS CL150/JIS

    -

    Pipe connection DIN 11851

    - - - 3…40 (1/10...1 1/2“) 50, 80 (2“, 3“)

    65, 100 (2 1/2“, 4“)

    40 16 10

    S S S

    Weld stubs DIN 11850 - - - 3 … 40 (1/10...1 1/2“)

    50, 80 (2“, 3“) 65, 100 (2 1/2“, 4“)

    40 16 10

    R R R

    Weld stubs DIN 2463 / ISO 1127

    - - - 3 … 40 (1/10...1 1/2“)50, 80 (2“, 3“)

    65, 100 (2 1/2“, 4“)

    40 16 10

    Q/J Q/J Q/J

    Weld stubs ISO 2037 / SMS - - - 25…40 (1...1 1/2“)

    50, 80 (2“, 3“) 65, 100 (2 1/2“, 4“)

    40 16 10

    P/X P/X P/X

    Tri-Clamp DIN 32676 / ASME BPE

    - - - 3 … 50 (1/10...2“) 65, 100 (2 1/2“, 4“)

    16/1010/10

    T/K T/K

    External threads ISO 228 / DIN 2999

    - - - 3 …25 (1/10...1”) 16 E

    1/8" sanitary connectors - - - 1 …2 (1/25...1/12”) 10 B

    Liner Hard/soft rubber, PTFE, PFA, ETFE, other PFA (vacuum tight) PFA (vacuum tight) PEEK, Torlon (< DN 3)

    PFA (> DN 2) Conductivity ≥ 20 µS/cm (optional ≥ 5/0.5 µS/cm) Electrodes SS 1.4571 (316 Ti), 1.4539 (904 L), Hastelloy B-3/C-4, Platinum-Iridium, Tantalum, Titanium

    Process Connection Material Steel, SS 1.4571 (316 Ti) 1.4404 (316 L) - > DN 2: SS 1.4404 (316 L) < DN 3: 1.4571 (316 Ti), PVC, POMProtect. Class per EN 60529 IP 67 / IP 68 IP 67 / IP 68 IP 67 / IP 68 IP 67 / IP 68

    Fluid Temperatures -25 ... 130 °C / 180 °C -13 ... 266 °F / 356 °F -40 ... 130 °C -40 ... 266 °F

    -25 ... 130 °C -13 ... 266 °F

    -25 ... 130 °C -13 ... 266 °F

    Approvals Hygienic + sterile requirem. CIP/SIP-enabled 3A, EHEDG, CIP/SIP-enabled

    Transmitter Model Number S4 Supply power 85 ... 253 V AC, 24 V AC/DC Current output 0/2 ... 10 mA, 0/4 ... 20 mA Pulse output active (24 V), optocoupler (220 mA) Ext. zero return yes Ext. totalizer reset yes Forward/Rev. Flow Metering yes Communication HART protocol, PROFIBUS PA, FOUNDATION Fieldbus Pipe empty detection std. yes, DN 10 or higher and ≥ 20 µS/cm Self-monitoring, enhanced diagnostic functions

    yes , expanded diagnostic functions / fingerprint only in connection with flowmeters SE21, SE21F and SE41F for DN 10 or higher

    On-site display/totalization yes Density correction yes, manual entry (totalize and display in mass units) Protect. Class per EN 60529 IP 67, NEMA 4X Housing Field housing unit

    G00212

    1) Weld stubs 2) Tri-Clamp 3) Threaded pipe connection 4) External threads Pos: 4 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    4

    Pos: 5 /==== Wechsel ein- auf zweispaltig ==== @ 0\mod_1130421847171_3101.doc @ 3828 Wechsel ein-auf zweispaltig Pos: 6 /Überschriften/1/A - C/Allgemeine Daten @ 0\mod_1132927923465_3101.doc @ 3133

    2 General information Pos: 7 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Allgemein/Messgenauigkeit @ 3\mod_1157629438861_3101.doc @ 39739

    2.1 Measuring accuracy

    2.1.1 Reference conditionsper EN 29104

    Fluid Temperatures 20 °C (68 °F) ± 2 K Ambient temp. 20 °C (68 °F) ± 2 K Supply power Line voltage per type plate UN ± 1% Installation Conditions − upstream > 10 x DN

    straight section − downstream > 5 x DN straight section DN = Flowmeter sensor size

    Warm Up Phase 30 min

    2.1.2 Maximum Measurement Error

    Pulse output − DN 1 ... DN 2 (1/25 ... 1/12"):

    ± 1% of measured value, ± 0.001 QmaxDN − DN 3 ... DN 1000 (1/10 ... 40"):

    Q > 0.05 QmaxDN ± 0.5% of measured value − Q < 0.05 QmaxDN ± 0.00025 QmaxDN QmaxDN = maximum flowrate for the flowmeter size 10 m/s Analog Output Effects Same as pulse output plus ±0.1% of rate ±0.01 mA

    0 6,5 13,1 19,7 26,2 32,8 ft/s

    G00456

    0,0 %

    1,0 %

    2,0 %

    3,0 %

    4,0 %

    5,0 %

    6,0 %

    0 2 4 6 8 10 m/s

    DN 3...1000(1/10...40”)

    DN 1...2(1/25...1/12”)

    Y

    X

    Fig. 1 Y Accuracy ± of rate X Flow velocity

    Pos: 8 /======= Spaltenumbruch ======== @ 0\mod_1132937966324_3101.doc @ 3831

    Pos: 9 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Allgemein/Erdung @ 11\mod_1184752201296_3101.doc @ 110913

    2.2 Grounding

    The grounding of the flowmeter sensor is necessary not only for safety reasons, but also to as sure proper operation of the electro-magnetic flowmeter. The ground screws on the flowmeter sensor are to be connected to earth potential. For technical reasons, this potential should be identical to the potential of the metering fluid, if possible. For plastic or insulated lined pipelines, the fluid is grounded by installing ground plates. When there are stray potentials present in the pipeline, a grounding plate is recommended on both ends of the meter sensor. For devices with hard rubber lining for DN 125 (5") and larger, the liner contains a conductive element. This ensures the measured medium is grounded. To comply with the EMC- and Low Voltage Regulations the connection box/transmitter must be grounded in addition to the meter tube of the flowmeter sensor. Pos: 10 /==== Leeres Modul mit einer Absatzmarke, DS, 1-spaltig ==== @ 2\mod_1153381574375_0.doc @ 35553

    Pos: 11.1 /Überschriften/1.1/2-spaltig/Einbaubedingungen @ 2\mod_1155119709593_3101.doc @ 38554

    2.3 Installation Requirements Pos: 11.2 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Einbaubedingungen/Allgemeine Hinweise @ 5\mod_1163075963593_3101.doc @ 46893

    The following points must be observed for the installation: • The meter tube must always be completely full. • The flow direction must correspond to the identification if present. • The maximum torque for all flange connections must be complied

    with. • The devices must be installed without mechanical tension

    (torsion, bending). • Install flange and wafer units with coplanar counter flanges and

    use only appropriate gaskets. • Use only flange seals made from a compatible material for the

    fluid and fluid temperatures. • Gaskets must not extend into the flow area since possible

    turbulence could influence the device accuracy. • The pipeline may not exert any unallowable forces or torques on

    the device. • Do not remove the plugs in the cable connectors until you are

    ready to install the electrical cable. • Install transmitter at a largely vibration-free location. • Do not expose the transmitter to direct sunlight or provide for

    appropriate sun protection where necessary. Pos: 11.3 /======= Spaltenumbruch ======== @ 0\mod_1132937966324_3101.doc @ 3831

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    5

    Pos: 11.4 /Technische Daten / Datenblatt/Durchfluss/FXE4000/Einbaubedingungen/Elektrodenachse @ 2\mod_1155119847515_3101.doc @ 38596

    2.3.1 Electrode axis

    Electrode axis (1) should be horizontal if at all possible or no more that 45° from horizontal.

    G00041

    max. 45°

    1

    Fig. 2 Pos: 11.5 /==== Leeres Modul mit einer Absatzmarke, DS, 1-spaltig ==== @ 2\mod_1153381574375_0.doc @ 35553

    Pos: 11.6 /Technische Daten / Datenblatt/Durchfluss/FXE4000/Einbaubedingungen/Ein- und Auslaufstrecke (BA + IA) @ 2\mod_1155134311203_3101.doc @ 38877

    2.3.2 In- and outlet pipe sections

    Straight inlet section Straight outlet section ≥ 3 x DN ≥ 2 x DN

    DN = Flowmeter sensor size • Do not install fittings, manifolds, valves etc. directly in front of the

    meter tube (1). • Butterfly valves must be installed so that the valve plate does not

    extend into the flowmeter sensor. • Valves or other turn-off components should be installed in the

    outlet pipe section (2). • For compliance with the measuring accuracy, observe the inlet

    and outlet pipe sections.

    G00037

    1 2

    3xDN 2xDN

    Fig. 3 Pos: 11.7 /==== Leeres Modul mit einer Absatzmarke, DS, 1-spaltig ==== @ 2\mod_1153381574375_0.doc @ 35553

    Pos: 11.8 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Einbaubedingungen/Vertikale Leitungen @ 3\mod_1157631734081_3101.doc @ 39823

    2.3.3 Vertical connections

    • Vertical installation for measuring abrasive fluids, preferably with flow in upward direction.

    G00206 Fig. 4 Pos: 11.9 /======= Spaltenumbruch ======== @ 0\mod_1132937966324_3101.doc @ 3831

    Pos: 11.10 /Technische Daten / Datenblatt/Durchfluss/FXE4000/Einbaubedingungen/Horizontale Leitungen @ 2\mod_1155120108937_3101.doc @ 38659

    2.3.4 Horizontal connections

    • Meter tube must always be completely full. • Provide for a slight incline of the connection for degassing.

    G00038

    Fig. 5 Pos: 11.11 /==== Leeres Modul mit einer Absatzmarke, DS, 1-spaltig ==== @ 2\mod_1153381574375_0.doc @ 35553

    Pos: 11.12 /Technische Daten / Datenblatt/Durchfluss/FXE4000/Einbaubedingungen/Freier Ein- bzw. Auslauf @ 2\mod_1155120144781_3101.doc @ 38680

    2.3.5 Free inlet or outlet

    • Do not install the flowmeter at the highest point or in the draining- off side of the pipeline, flowmeter runs empty, air bubbles can form (1).

    • Provide for a siphon fluid intake for free inlets or outlets so that the pipeline is always full (2).

    G00040

    1

    2

    Fig. 6 Pos: 11.13 /==== Leeres Modul mit einer Absatzmarke, DS, 1-spaltig ==== @ 2\mod_1153381574375_0.doc @ 35553

    Pos: 11.14 /Technische Daten / Datenblatt/Durchfluss/FXE4000/Einbaubedingungen/Stark verschmutzte Messstoffe @ 2\mod_1155120187750_3101.doc @ 38701

    2.3.6 Strongly contaminated fluids

    • For strongly contaminated fluids, a bypass connection according to the figure is recommended so that operation of the system can continue to run without interruption the during the mechanical cleaning.

    G00042 Fig. 7 Pos: 11.15 /==== Leeres Modul mit einer Absatzmarke, DS, 1-spaltig ==== @ 2\mod_1153381574375_0.doc @ 35553

    Pos: 11.16 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Einbaubedingungen/Montage in der Nähe von Pumpen @ 3\mod_1157631958985_3101.doc @ 39844

    2.3.7 Installation in the vicinity of pumps

    • For flowmeter primaries that are installed near pumps or other vibration-causing fixtures, the use of mechanical vibration control components is mandatory.

    G00207 Fig. 8 Pos: 11.17 /======= Spaltenumbruch ======== @ 0\mod_1132937966324_3101.doc @ 3831

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    6

    Pos: 11.18 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Einbaubedingungen/Einbau in Rohrleitungen größerer Nennweiten @ 3\mod_1157632081771_3101.doc @ 39865

    2.3.8 Installation in larger size pipelines

    Determine the resulting pressure loss when using reduction pieces (1): 1. Calculate the diameter ratio d/D. 2. Determine the flow velocity based on the flow range nomograph

    (Fig. 10). 3. Read the pressure drop on the Y-axis in Fig. 10.

    G00213

    D d

    1

    Fig. 9 1 d V Δp D

    = Flange reducer = Inside diameter of the flowmeter = flow velocity [m/s] = pressure drop [mbar] = Inside diameter of the pipeline

    Nomograph for pressure drop calculations For flange transition piece with α/2 = 8°

    Fig. 10 Pos: 12 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    7

    Pos: 13 /==== Wechsel zwei- auf einspaltig ==== @ 0\mod_1130421955859_3101.doc @ 3829

    Wechsel ein-auf zweispaltig Pos: 14 /Überschriften/1.1/1-spaltig/M - O/Nennweite, Nenndruck, Messbereich @ 17\mod_1201168918704_3101.doc @ 154023

    2.4 Flowmeter Sizes, Pressure Ratings, Flow Range Pos: 15 /Technische Daten / Datenblatt/Durchfluss/FXE4000/Messbereich @ 7\mod_1175088848531_3101.doc @ 74665

    2.5 Flowmeter Sizes, Pressure Ratings, Flow Range

    Meter Size Std. Press. Rating PN

    Min. Flow Range Flow Velocity 0 … 0.5 m/s

    Max. Flow Range Flow Velocity 0 … 10 m/s

    3 4 6

    1/10 5/32 1/4

    40 40 40

    0 0 0

    … … …

    0.2 0.4

    1

    l/min l/min l/min

    0.1 0.1 0.3

    US gal/min US gal/min US gal/min

    0 0 0

    … … …

    4 8

    20

    l/min l/min l/min

    1.1 2.1 5.3

    US gal/min US gal/min US gal/min

    8 10 15 20

    5/16 3/8 1/2 3/4

    40 40 40 40

    0 0 0 0

    … … … …

    1.5 2.25 5.0 7.5

    l/min l/min l/min l/min

    0.4 0.6 1.3 2.0

    US gal/min US gal/min US gal/min US gal/min

    0 0 0 0

    … … … …

    30 45

    100 150

    l/min l/min l/min l/min

    7.9 12 36 40

    US gal/min US gal/min US gal/min US gal/min

    25 32 40

    1 1 1/4 1 1/2

    40 40 40

    0 0 0

    … … …

    10 20 30

    l/min l/min l/min

    2.6 5.3 7.9

    US gal/min US gal/min US gal/min

    0 0 0

    … … …

    200 400 600

    l/min l/min l/min

    53 106 159

    US gal/min US gal/min US gal/min

    50 65 80

    2 2 1/2

    3

    40 40 40

    0 0 0

    … … …

    3 6 9

    m3/h m3/h m3/h

    13 26 40

    US gal/min US gal/min US gal/min

    0 0 0

    … … …

    60 120 180

    m3/h m3/h m3/h

    264 528 793

    US gal/min US gal/min US gal/min

    100 125 150

    4 5 6

    16 16 16

    0 0 0

    … … …

    12 21 30

    m3/h m3/h m3/h

    53 92

    132

    US gal/min US gal/min US gal/min

    0 0 0

    … … …

    240 420 600

    m3/h m3/h m3/h

    1057 1849 2642

    US gal/min US gal/min US gal/min

    200 250 300

    8 10 12

    10/16 10/16 10/16

    0 0 0

    … … …

    54 90

    120

    m3/h m3/h m3/h

    238 396 528

    US gal/min US gal/min US gal/min

    0 0 0

    … … …

    1080 1800 2400

    m3/h m3/h m3/h

    4755 7925

    10567

    US gal/min US gal/min US gal/min

    350 400 450 500

    14 16 18 20

    10/16 10/16 10/16

    10

    0 0 0 0

    … … … …

    165 225 300 330

    m3/h m3/h m3/h m3/h

    726 991

    1321 1453

    US gal/min US gal/min US gal/min US gal/min

    0 0 0 0

    … … … …

    3300 4500 6000 6600

    m3/h m3/h m3/h m3/h

    14529 19813 26417 29059

    US gal/min US gal/min US gal/min US gal/min

    600 700 800

    24 28 32

    10 10 10

    0 0 0

    … … …

    480 660 900

    m3/h m3/h m3/h

    2113 2906 3963

    US gal/min US gal/min US gal/min

    0 0 0

    … … …

    9600 13200 18000

    m3/h m3/h m3/h

    30380 58118 79252

    US gal/min US gal/min US gal/min

    900 1000

    36 40

    10 10

    0 0

    … …

    1200 1350

    m3/h m3/h

    5283 5944

    US gal/min US gal/min

    0 0

    … …

    24000 27000

    m3/h m3/h

    105669 118877

    US gal/min US gal/min

    Pos: 16 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    8

    Pos: 17 /==== Wechsel ein- auf zweispaltig ==== @ 0\mod_1130421847171_3101.doc @ 3828 Wechsel ein-auf zweispaltig Pos: 18 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Allgemein/Durchflussnomogramm @ 3\mod_1157633105784_3101.doc @ 39886

    Flange design and pressure rating Meter size Flange 1) Material PN PED

    3 ... 25 (1/10 ... 1")

    DIN ASME

    JIS

    SS 1.4571 (316 Ti) or steel

    40 bar CL150, CL300

    10 bar

    SEP Art.3

    para.332

    (1 1/4") DIN

    ASME JIS

    SS 1.4571 (316 Ti) or steel

    40 bar CL150, CL300

    10 bar 40

    (1 1/2") DIN

    ASME JIS

    SS 1.4571 (316 Ti) or steel

    40 bar CL150, CL300

    10 bar 50 (2")

    DIN ASME

    JIS

    SS 1.4571 (316 Ti) or steel

    40 bar CL150, CL300

    10 bar 65

    (2 1/2") DIN

    ASME JIS

    SS 1.4571 (316 Ti) or steel

    16, 40 bar CL150, CL300

    10 bar 80 (3")

    DIN ASME

    JIS

    SS 1.4571 (316 Ti) or steel

    40 bar CL150, CL300

    10 bar 100 (4")

    DIN ASME

    JIS

    SS 1.4571 (316 Ti) or steel

    16, 40 bar CL150, CL300

    10 bar 125 (5")

    DIN ASME

    SS 1.4571 (316 Ti) or steel

    16, 40 bar CL150, CL300

    150 (6")

    DIN ASME

    SS 1.4571 (316 Ti) or steel

    16, 40 bar CL150, CL300

    200 (8")

    DIN ASME

    SS 1.4571 (316 Ti) or steel

    10, 16, 25, 40 barCL150, CL300

    250 (10")

    DIN ASME

    SS 1.4571 (316 Ti) or steel

    10, 16, 25, 40 barCL150, CL300

    300 (12")

    DIN ASME

    SS 1.4571 (316 Ti) or steel

    10, 16, 25, 40 barCL150, CL300

    350 ... 1000 (14 ... 40")

    DIN ASME

    SS 1.4571 (316 Ti) or steel

    10, 16, 25 bar CL150

    Con

    form

    ity a

    sses

    smen

    t in

    acco

    rdan

    ce w

    ith c

    ateg

    ory

    III, m

    odul

    e B

    1 +

    D, f

    luid

    gro

    up 1

    1) Connecting dimensions for flange acc. to DIN2501 / EN1092-1 or ASME or JIS.

    Other meter sizes, pressure stages and temperature classes are available upon request.

    2.6 Flowrate nomograph

    The volume flowrate is a function of the flow velocity and the diameter of the flowmeter. The flowrate nomograph indicates the flowrate range for a specific flowmeter size and which flowmeter sizes are suitable for a specific flowrate.

    G00225

    l/min l/s3/hm

    5

    4

    3

    2

    103

    102

    8

    65

    4

    3

    2

    8

    654

    3

    2

    10-1

    10

    8

    65

    4

    3

    8

    65

    4

    3

    2

    2

    1

    8

    65

    4

    3

    2

    8

    65

    4

    3

    2

    8

    65

    4

    3

    2

    8

    654

    3

    10-1

    10-2

    10-3

    10

    8

    654

    3

    2

    1

    8

    654

    3

    2

    8

    65

    4

    3

    2

    DN10

    0

    DN80

    DN65

    DN50

    DN

    40

    DN

    32

    DN

    25

    DN20

    DN15

    DN10

    DN8

    DN6

    DN4

    DN

    3

    DN2

    DN1.

    5

    DN1

    32 4 5 6 8 1010,80,60,5

    m/s

    10-3

    10-1

    10-2

    8

    654

    3

    2

    8

    65

    4

    3

    2

    8

    65

    4

    3

    2

    1

    10

    8

    65

    4

    3

    2

    102

    8

    654

    3

    2

    3

    2

    1

    Fig. 11: Flowrate nomograph DN 1 ... DN 100 (1/25 ... 4") 1 Example

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    9

    G00226

    l/min 3/hm l/s

    103

    8

    6

    5

    4

    3

    2

    108

    6

    54

    4

    3

    3

    2

    2

    108

    6

    5

    4

    3

    2

    4

    5

    104

    8

    65

    4

    3

    3

    2

    2

    103

    8

    65

    4

    3

    2

    10

    10

    8

    654

    3

    2

    2

    32 4 5 6 8 1010,80,60,5

    m/s

    10

    8

    654

    3

    2

    8

    65

    4

    3

    2

    10

    3

    8

    654

    3

    2

    10

    654

    3

    2

    DN

    250D

    N30

    0DN

    350

    DN

    400

    DN

    450D

    N50

    0DN60

    0DN

    700D

    N80

    0DN

    900D

    N10

    00

    DN

    125D

    N15

    0

    DN20

    0

    Fig. 12: Flowrate nomograph DN 125 ... DN 1000 (5 ... 40")

    Example: Flowrate = 7 m3/h (max. value = range end value). Flowmeter sizes DN 20 ... DN 65 (3/4 ... 2 1/2“) are suitable for a flow velocity between 0.5 ... 10 m/s. Pos: 19 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    10

    Pos: 20 /==== Wechsel zwei- auf einspaltig ==== @ 0\mod_1130421955859_3101.doc @ 3829

    Wechsel ein-auf zweispaltig Pos: 21 /Überschriften/1/M - O/Modell SE41F @ 3\mod_1157708869843_3101.doc @ 40854

    3 Model SE41F Pos: 22 /Überschriften/1.1/1-spaltig/S - U/Technische Daten @ 7\mod_1157704677334_3101.doc @ 40581

    3.1 Technical data Pos: 23 /==== Wechsel ein- auf zweispaltig ==== @ 0\mod_1130421847171_3101.doc @ 3828 Wechsel ein-auf zweispaltig Pos: 24 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Technische Daten/Messaufnehmer/Modell SE41F @ 3\mod_1157634558052_3101.doc @ 39949

    Temperature graph

    G00214

    1

    2

    3

    4 6

    5

    Fig. 13: Fluid temperature as function of ambient temperature

    1 Ambient temperature °C 2 Fluid temperature °C 3 Standard flange (steel): Hard/soft rubber max. 90/60 °C

    (194 ... 140 °F) 4 with stainless steel flange 5 Standard flange (steel): PTFE/PFA/ETFE max.130 °C (266°F) 6 High temperature: Thick PTFE / PFA max. 180 °C (356 °F)

    Max. allowable cleaning temperature PTFE-, PFA-design CIP-Cleaning Liner

    Flowmeter sensor

    Tmax tmax Min.

    Tamb.

    Steam cleaning PTFE, PFA 150 °C (302 °F) 60 25 °C (77 °F)Liquid cleaning PTFE, PFA 140 °C (284 °F) 60 25 °C (77 °F)If the ambient temperature is > 25 °C, then the difference must be subtracted from the max. cleaning temperature. Tmax - Δ °C.Δ °C = (Tamb. - 25 °C) Weight Refer to dimensional drawings Min. allowable pressure as factor of fluid temperature Liner Nominal size

    DN POperation mbar abs

    at TOperating

    Hard rubber 15 … 1000 (1/2 … 40“)

    0 < 90 °C (194 °F)

    Soft rubber 50 … 1000 (2 … 40“)

    0 < 60 °C (140 °F)

    PTFE 10 … 600 (3/8 … 24“)

    270 400 500

    < 20 °C (68 °F) < 100 °C (212 °F)< 130°C (266 °F)

    Thick PTFE High temperature Design

    25 … 80 (1 … 3“)

    100 … 250 (4 … 10“) 300 (12“)

    0

    67

    27

    < 180 °C (356 °F)

    < 180 °C (356 °F)

    < 180 °C (356 °F)PFA 3 … 200

    (1/10 … 8“) 0 0

    < 130°C (266 °F)< 180 °C (356 °F)

    ETFE 25 ... 1000 (1 ... 40“)

    100 < 130 °C (266 °F)

    Flowmeter sensor material Parts Standard Options Liner PTFE, PFA, hard/soft

    rubber, ETFE −

    Signal and ground electrode for - Hard rubber - Soft rubber

    SS 1.4571 (316 Ti) Hastelloy B-3 (2.4600), Hastelloy C-4 (2.4610), Titanium, tantalum, platinum iridium, SS 1.4539 (904 L)

    - PTFE, PFA, ETFE

    Hastelloy C-4 (2.4610)

    SS 1.4571 (316 Ti) Hastelloy B-3 (2.4600), Titanium, tantalum, platinum iridium, SS 1.4539 (904 L)

    Grounding plate SS 1.4571 (316 Ti) upon request Protection plate SS 1.4571 (316 Ti) upon request

    Process connection material Parts Standard Options Flanges DN 3 ... DN 15 (1/10 ... 1/2“)

    SS 1.4571 (316 Ti), standard

    DN 20 ... DN 300 (3/4 ... 10“)

    Galvanized: DIN/EN: 1.0038/1.0570/1.0460 ASME: A105/C21

    DN 350 ... DN 1000 (18 ... 40“)

    Painted: DIN/EN: 1.0038/1.0570/1.0460 ASME: A105/C21

    SS 1.4571 (316 Ti)

    Housing DN 3 ... 300 (1/10 ... 10“)

    Dual-shell casing Al casting, painted, paint coat, 80 µm thick, RAL 9002

    DN 350 ... DN 1000 (18 ... 40“)

    Welded steel design, painted, paint coat, 80 µm thick, RAL 9002

    Connection box Al alloy, painted, 80 µm dick, frame: dark gray, RAL 7012 Cover: light gray, RAL 9002

    Meter tube SS 1.4301 (304) − PG-Connector Polyamide −

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    11

    Storage Temperature -20 ... 70 °C (-4 ... 158 °F) Protection Class per EN 60529 IP 67 IP 68 (option) Pipeline Vibration Following EN 60068-2-6 Transmitter - In the range of 10…55 Hz, max. deflection 0.15 mm Flowmeter sensor - In the range of 10…55 Hz, max. deflection 0.15 mm - In the range of 10…55 Hz, max. acceleration 2 g Designs The flanged flowmeters comply with the installation lengths specified in VDI / VDE 2641, ISO 13359 or according to DVGW (process sheet W420, design WP; ISO 4064 short). Material load Limits for allowable fluid temperature (TS) and allowable pressure (PS) are a function of the liner and flange material used (see the builder's and model plate of the unit). Temperature limits

    Max. temperature Liner Flange material

    Min. temperature Standard High

    temperatureHard rubber Steel

    SS 1.4571 (316 Ti)

    -10 °C (14 °F) -15 °C (5°F)

    90 °C (194 °F) 90 °C

    (194 °F)

    − −

    Soft rubber Steel SS 1.4571 (316 Ti)

    -10 °C (14 °F) -15 °C (5 °F)

    60 °C (140 °F) 60 °C

    (140 °F)

    − −

    PTFE / PFA / ETFE

    Steel SS 1.4571 (316 Ti)

    -10 °C (14 °F) -25 °C

    (-13 °F)

    130 °C (266 °F) 130 °C

    (266 °F)

    − −

    Thick PTFE / PFA

    Steel SS 1.4571 (316 Ti)

    -10 °C (14 °F) -25 °C

    (-13 °F)

    130 °C (266 °F) 130 °C

    (266 °F)

    180 °C (356 °F) 180 °C

    (356 °F)

    G00215

    PN 40

    PN 25

    PN 16

    PN 10

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    -30 -10 10 30 50 70 90 110 130 150 170 190 [°C]

    PS[bar]

    -22 14 50 86 122 158 194 230 266 302 338 374 [°F]TS

    0

    72.5

    145.0

    217.5

    290.0

    362.5

    435.0

    507.5

    580.0

    652.5

    PS[psi]

    Fig. 14: DIN flanges SS 1.4571 (316 Ti) to DN 600 (24")

    G00216

    PS[bar]

    TS

    CL 300

    CL 150

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    50

    55

    -30 -10 10 30 50 70 90 110 130 150 170 190 [°C]

    -22 14 50 86 122 158 194 230 266 302 338 374 [°F]

    PS[psi]

    72.5

    145.0

    217.5

    290.0

    362.5

    435.0

    507.5

    580.0

    652.5

    725.5

    797.5

    0

    Fig. 15: ASME flange SS 1.4571 (316 Ti) to DN 300 (CL150/300) to DN 1000 (CL150)

    G00217

    PS[bar]

    TS-30 -10 10 30 50 70 90 110 130 150 170 190 [°C]

    -22 14 50 86 122 158 194 230 266 302 338 374 [°F]

    PN 40

    PN 25

    PN 16

    PN 10

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    PS[psi]

    0

    72.5

    145.0

    217.5

    290.0

    362.5

    435.0

    507.5

    580.0

    652.5

    Fig. 16: DIN flange SS 1.4571 (316 Ti) to DN 600 (24“)

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    12

    G00218

    PS[bar]

    TS-30 -10 10 30 50 70 90 110 130 150 170 190 [°C]

    -22 14 50 86 122 158 194 230 266 302 338 374 [°F]

    CL 300

    CL 150

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    50

    55

    PS[psi]

    0

    72.5

    145.0

    217.5

    290.0

    362.5

    435.0

    507.5

    580.0

    652.5

    725.0

    797.5

    Fig. 17: ASME flange steel to DN 300 (CL150/300) to DN 1000 (CL150)

    JIS 10K-B2210 Flange Nominal size DN

    Material PN TS PS [bar]

    32 … 300 (1¼ … 12“)

    SS 1.4571 (316 Ti)

    10 -25 … +180 °C (-13 … +356 °F)

    10

    32 … 300 (1¼ … 12“)

    Steel 10 -10 … +180 °C (14 … 266 °F)

    10

    G00219

    PS[bar]

    TS

    6

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    DN 700 PN 16

    DN 900 PN 16DN 800 PN 16

    DN 1000 PN 16

    DN 900 PN10DN 800 PN 10DN 700 PN 10

    DN 1000 PN 10

    -30 -20 -10 0 10 20 30 40 50 60 70 80 90 [°C]

    -22 -4 14 32 50 68 86 104 122 140 158 176 194 [°F]

    PS[psi]

    87.0

    101.5

    116.0

    130.5

    145.0

    159.5

    174.0

    188.5

    203.0

    217.5

    232.0

    246.5

    Fig. 18: DIN flange SS 1.4571 (316 Ti), DN 700 ... DN 1000 (28 ... 40“)

    G00220

    PS[bar]

    TS

    DN 700 PN 16

    DN 900 PN 16DN 800 PN 16

    DN 1000 PN 16

    DN 900 PN 10DN 800 PN 10DN 700 PN 10

    DN 1000 PN 106

    7

    8

    9

    10

    11

    12

    13

    14

    15

    16

    17

    -10 0 10 20 30 40 50 60 70 80 90 [°C]

    -14 32 50 68 86 104 122 140 158 176 194 [°F]

    PS[psi]

    87.0

    101.5

    116.0

    130.5

    145.0

    159.5

    174.0

    188.5

    203.0

    217.5

    232.0

    246.5

    Fig. 19: DIN flange steel, DN 700 ... DN 1000 (28 ... 40“) Pos: 25 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    13

    Pos: 26 /==== Wechsel zwei- auf einspaltig ==== @ 0\mod_1130421955859_3101.doc @ 3829

    Wechsel ein-auf zweispaltig Pos: 27.1 /Überschriften/1.1/1-spaltig/M - O/Maßzeichnungen @ 11\mod_1157707121639_3101.doc @ 40791

    3.2 Dimensional drawings Pos: 27.2 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Maßzeichnungen/Durchflussmesser SE41/Maßzeichnung Flansch DN3-DN300 (DIN) @ 3\mod_1157638227388_3101.doc @ 40075

    3.2.1 Model SE41F

    Flange acc. to DIN / EN 1092-15), DN 3 … DN 300; ASME B16.5, 1/10 ... 12"

    G00227

    H

    ØD2

    k

    FE G

    88 (3,46)

    35 (1,38)

    A b

    L*

    Ød4

    ØD

    d2

    EF

    G

    k

    88 (3,46)

    35 (1,38)1

    2

    1

    2

    Tolerance: L* DN 3 ... DN 200: +0/-3 (0.12"); DN 250 ... DN 300: +0/-5 (0.20")

    Tolerance: L* 1/10 ... 8": +0/-3 (0.12“); 10 ... 12“: +0/-5 (0.20“) Fig. 20: Dimensions in mm (inch) 1 Cable gland M20 x 1.5 or NPT 2 Number of holes N

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    14

    Flange dimensions acc. to DIN / EN Meter dimensions acc. to DIN / EN Wht.

    mm mm DN PN1)

    D/H d4 b k d2 N A L* L2) L3) E4) F G4) kg

    3…86) 10 15 20

    10 … 40 10 … 40 10 … 40 10 … 40

    90 90 95

    105

    40 40 45 58

    18 18 18 20

    60 60 65 75

    14 14 14 14

    4 4 4 4

    67 67 67 87

    130200200200

    133203203203

    136 206 206 206

    101 101 101 112

    62 62 62 73

    129129129140

    2.5 3 3

    3.5 25 32 40

    10 … 40 10 … 40 10 … 40

    115 140 150

    68 78 88

    20 20 20

    85 100 110

    14 18 18

    4 4 4

    87 95

    100

    200200200

    203203203

    206 206 206

    112 117 121

    73 78 82

    140145149

    4 5 6

    50 10 … 40 165 102 21 125 18 4 116 200 203 206 129 90 157 8 655)

    10 … 16 25 … 40

    185 185

    122122

    21 25

    145 145

    18 18

    4 8

    100100

    200200

    203203

    206 206

    153 153

    104 104

    171171

    12 12

    80 10 … 40 200 138 27 160 18 8 100 200 203 206 159 110 177 16 100

    10 … 16 25 … 40

    220 235

    158162

    23 27

    180 190

    18 22

    8 8

    130130

    250250

    253253

    256 256

    179 179

    130 130

    197197

    15 15

    125

    10 … 16 25 … 40

    250 270

    188188

    25 29

    210 220

    18 26

    8 8

    124124

    250250

    255255

    260 260

    170 170

    127 127

    195195

    23 30

    150

    10 … 16 25 … 40

    285 300

    212218

    25 31

    240 250

    22 26

    8 8

    170170

    300300

    305305

    310 310

    190 190

    148 148

    216216

    28 34

    200

    10 16

    340 340

    268268

    28 28

    295 295

    22 22

    8 12

    195195

    350350

    355355

    360 360

    222 222

    179 179

    248248

    54 54

    250

    10 16

    395 405

    320320

    30 30

    350 355

    22 26

    12 12

    250250

    450450

    455455

    460 460

    250 250

    207 207

    276275

    80 80

    300

    10 16

    445 460

    370378

    31 33

    400 410

    22 26

    12 12

    250250

    500500

    505505

    510 510

    293 293

    250 250

    318318

    83 92

    inch inch DN PN1)

    D/H d4 b k d2 N A L* L2) L3) E4) F G4) lb

    3…86) 10 15 20

    10 … 40 10 … 40 10 … 40 10 … 40

    3.54 3.54 3.74 4.13

    1.571.571.772.28

    0.71 0.71 0.71 0.79

    2.36 2.36 2.56 2.95

    0.550.550.550.55

    0.160.160.160.16

    2.642.642.643.43

    5.127.877.877.87

    5.247.997.997.99

    5.35 8.11 8.11 8.11

    3.98 3.98 3.98 4.41

    2.44 2.44 2.44 2.87

    5.085.085.085.51

    5.516.616.617.72

    25 32 40

    10 … 40 10 … 40 10 … 40

    4.53 5.51 5.91

    2.683.073.46

    0.79 0.79 0.79

    3.35 3.94 4.33

    0.550.710.71

    0.160.160.16

    3.433.743.94

    7.877.877.87

    7.997.997.99

    8.11 8.11 8.11

    4.41 4.61 4.76

    2.87 3.07 3.23

    5.515.715.87

    8.8211.0213.23

    50 10 … 40 6.50 4.02 0.83 4.92 0.71 0.16 4.57 7.87 7.99 8.11 5.08 3.54 6.18 17.64 655)

    10 … 16 25 … 40

    7.28 7.28

    4.804.80

    0.83 0.98

    5.71 5.71

    0.710.71

    0.160.31

    3.943.94

    7.877.87

    7.997.99

    8.11 8.11

    6.02 6.02

    4.09 4.09

    6.736.73

    26.4626.46

    80 10 … 40 7.87 5.43 1.06 6.30 0.71 0.31 3.94 7.87 7.99 8.11 6.26 4.33 6.97 35.27 100

    10 … 16 25 … 40

    8.66 9.25

    6.226.38

    0.91 1.06

    7.09 7.48

    0.710.87

    0.310.31

    5.125.12

    9.849.84

    9.969.96

    10.08 10.08

    7.05 7.05

    5.12 5.12

    7.767.76

    33.0733.07

    125

    10 … 16 25 … 40

    9.84 10.63

    7.407.40

    0.98 1.14

    8.27 8.66

    0.711.02

    0.310.31

    4.884.88

    9.849.84

    10.0410.04

    10.24 10.24

    6.69 6.69

    5.00 5.00

    7.687.68

    50.7166.14

    150

    10 … 16 25 … 40

    11.22 11.81

    8.358.58

    0.98 1.22

    9.45 9.84

    0.871.02

    0.310.31

    6.696.69

    11.8111.81

    12.0112.01

    12.20 12.20

    7.48 7.48

    5.83 5.83

    8.508.50

    61.7374.96

    200

    10 16

    13.39 13.39

    10.55 10.55

    1.10 1.10

    11.6111.61

    0.870.87

    0.310.47

    7.687.68

    13.7813.78

    13.9813.98

    14.17 14.17

    8.74 8.74

    7.05 7.05

    9.769.76

    119.05119.05

    250

    10 16

    15.55 15.94

    12.60 12.60

    1.18 1.18

    13.7813.98

    0.871.02

    0.470.47

    9.849.84

    17.7217.72

    17.9117.91

    18.11 18.11

    9.84 9.84

    8.15 8.15

    10.8710.83

    176.37176.37

    300

    10 16

    17.52 18.11

    14.57 14.88

    1.22 1.30

    15.7516.14

    0.871.02

    0.470.47

    9.849.84

    19.6919.69

    19.8819.88

    20.08 20.08

    11.54 11.54

    9.84 9.84

    12.5212.52

    182.98202.83

    1) Other pressure stages upon request. 2) Standard with a grounding plate mounted on one side of flange in SS 1.4571 (316 Ti). Other materials upon request. For additional information, see "Grounding". DN 3 ... DN 100 L + 3 mm (0.12"), DN 125 ... DN 300 L + 5 mm (0.20"). 3) With protective flanges. The protective flanges provide the grounding function, grounding plate is not required. DN 3 ... DN 100, DN 125 ... DN 300 L + 10 mm (0.39"). Also available with protective flanges in 1000 series. Installation length ≤ DN 80 L+ 20 mm (0.79"), for DN 100 or higher L+ 25 mm (0.98"). 4) For high temperature designs < DN 125 + 20 mm (0.79"), > DN 100 + 120 mm (4.72"). 5) Connecting dimensions acc. to EN1092-1. For DN 65 / PN 16 acc. to EN1092-1 please order PN 40. 6) Connection flange DN10. Pos: 27.3 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    15

    Pos: 27.4 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Maßzeichnungen/Durchflussmesser SE41/Maßzeichnung Flansch DN3-DN300 (ASME) @ 3\mod_1157638358417_3101.doc @ 40096

    Meter dimensions acc. to ASME

    CL 150 / CL 300 Flange dimensions acc. to ASME

    CL 150 Flange dimensions acc. to ASME

    CL 300 Weight

    mm mm mm A L1) 2) E3) F G D/H d4 b k d2 N D/H d4 b k d2 N

    Inch ISO 13359

    old Inst.

    lngth.

    CL 150/ CL 300

    kg

    1/10...5/16 3/8. 1/2

    3/4 1

    67 67 87 87

    130 200 200 200

    130 270 270 270

    101 101 112 112

    62 62 73 73

    129 129 140 140

    89 89 99

    108

    35354351

    13131416

    60607080

    16161616

    4444

    9595

    117124

    35354351

    16 16 18 20

    67 67 83 89

    16 16 19 19

    4444

    2.5 3

    3.5 4

    1 1/4 1 1/2

    2

    95 100 116

    200 200 200

    280 280 280

    117 121 129

    78 82 90

    145 149 157

    117 127 152

    647392

    182021

    8999

    121

    161619

    444

    134156165

    647392

    21 23 24

    99 115 127

    19 23 19

    448

    5 6 8

    2 1/2 3 4

    100 100 130

    200 200 250

    330 340 400

    153 159 179

    104 110 130

    171 177 197

    178 191 229

    105127157

    252626

    140153191

    191919

    448

    191210254

    105127157

    27 30 34

    150 168 200

    23 23 22

    888

    12 16 15

    5 6 8

    10

    124 170 195 250

    250 300 350 450

    450 450 500 550

    169 190 222 250

    127 148 179 207

    195 216 248 276

    254 279 343 406

    186216270324

    28303435

    216241298362

    22222225

    888

    12

    280318381445

    186216270324

    39 41 47 53

    235 270 330 387

    22 22 25 28

    8121216

    36/38 38 66 98

    12 250 500 620 293 250 319 483 381 37 432 26 12 521 381 56 451 32 16 124/181 inch inch inch

    A L1) 2) E3) F G D/H d4 b k d2 N D/H d4 b k d2 N Inch ISO

    13359 old

    Inst. lngth.

    CL 150/ CL 300

    lb

    1/10...5/16 3/8. 1/2

    3/4 1

    2.64 2.64 3.43 3.43

    5.12 7.87 7.87 7.87

    5.12 10.63 10.63 10.63

    3.983.984.414.41

    2.44 2.44 2.87 2.87

    5.08 5.08 5.51 5.51

    3.503.503.904.25

    1.381.381.692.01

    0.510.510.550.63

    2.362.362.763.15

    0.630.630.630.63

    0.160.160.160.16

    3.743.744.614.88

    1.381.381.692.01

    0.63 0.63 0.71 0.79

    2.64 2.64 3.27 3.50

    0.63 0.63 0.75 0.75

    0.160.160.160.16

    5.5 6.6 7.7 8.8

    1 1/4 1 1/2

    2

    3.74 3.94 4.57

    7.87 7.87 7.87

    11.02 11.02 11.02

    4.614.765.08

    3.07 3.23 3.54

    5.71 5.87 6.18

    4.615.005.98

    2.522.873.62

    0.710.790.83

    3.503.904.76

    0.630.630.75

    0.160.160.16

    5.286.146.50

    2.522.873.62

    0.83 0.91 0.94

    3.90 4.53 5.00

    0.75 0.91 0.75

    0.160.160.31

    11.0 13.2 17.6

    2 1/2 3 4

    3.94 3.94 5.12

    7.87 7.87 9.84

    12.99 13.39 15.75

    6.026.267.05

    4.09 4.33 5.12

    6.73 6.97 7.76

    7.017.529.02

    4.135.006.18

    0.981.021.02

    5.516.027.52

    0.750.750.75

    0.160.160.31

    7.528.27

    10.00

    4.135.006.18

    1.06 1.18 1.34

    5.91 6.61 7.87

    0.91 0.91 0.87

    0.310.310.31

    26.5 35.3 33.1

    5 6 8

    10

    4.88 6.69 7.68 9.84

    9.84 11.81 13.78 17.72

    17.72 17.72 19.69 21.65

    6.657.488.749.84

    5.00 5.83 7.05 8.15

    7.68 8.50 9.76

    10.87

    10.0010.9813.5015.98

    7.328.50

    10.6312.76

    1.101.181.341.38

    8.509.49

    11.7314.25

    0.870.870.870.98

    0.310.310.310.47

    11.0212.5215.0017.52

    7.328.50

    10.6312.76

    1.54 1.61 1.85 2.09

    9.25 10.63 12.99 15.24

    0.87 0.87 0.98 1.10

    0.310.470.470.63

    79.4/83.8 83.8

    145.5 216.1

    12 9.84 19.69 24.41 11.54 9.84 12.56 19.02 15.00 1.46 17.01 1.02 0.47 20.51 15.00 2.20 17.76 1.26 0.63 273.4/399.0

    1) With a grounding plate mounted on one side of flange in SS 1.4571 (316 Ti), 1/10 ... 5/16" L + 3 mm (0.12"), 5 ... 12" L + 5 mm (0.20"). Other materials upon request. For additional information. see "Grounding". 2) With protective flanges. The protective flanges provide the grounding function, grounding plate is not required, 1/10 ... 5/16“ L + 6 mm (0.24"), 5 ... 12" L + 10 mm (0.39"). Also available with protective flanges in 1000 series. Installation length ≤ 3" L + 20 mm (0.79"), for 4" or higher L + 25 mm (0.98"). 3) For high temperature designs < 5" + 20 mm (0.79"), > 4" + 120 mm (4.72"). 4) Connection flange 1/2". Pos: 27.5 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    16

    Pos: 27.6 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Maßzeichnungen/Durchflussmesser SE41/Maßzeichnung Flansch DN350-DN1000 (DIN) @ 3\mod_1157638408849_3101.doc @ 40117

    Flange acc. to DIN / EN 1092-14). DN 350 ... DN 1000; ASME B16.5 / ASME B16.47 Series B. 14 ... 40"

    G00228d4

    b k

    D

    d2

    A

    EG

    F

    L*

    12

    Tolerance: L* DN 350 ... DN 500: +0/-5 (0.20"); DN 600 ... DN 1000: +0/-10 (0.39“)

    Tolerance: L* 14 ... 20“: +0/-5 (0.20“); 24 ... 40“: +0/-10 (0.39“) Fig. 21: Dimensions in mm (inch) 1 Cable gland M20 x 1.5 or NPT 2 Number of holes N

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    17

    Flange dimensions acc. to DIN / EN Meter dimensions acc. to DIN / EN Weight

    mm mm DN PN1) D k d4 d2 N b A L L2) L3) G E F

    appr. kg

    350 350

    10 16

    505 520

    460 470

    430 438

    22 26

    16 16

    31 35

    322322

    550550

    555555

    560560

    341 341

    313 313

    250250

    126 140

    400 400

    10 16

    565 580

    515 525

    482 490

    26 30

    16 16

    31 37

    370370

    600600

    605605

    610610

    367 367

    339 339

    275275

    155 175

    500 500

    10 16

    670 715

    620 650

    585 610

    26 33

    20 20

    33 39

    407407

    650650

    655655

    660660

    403 403

    375 375

    310310

    191 235

    600 600

    10 16

    780 840

    725 770

    685 725

    30 36

    20 20

    33 41

    469469

    780780

    785785

    790790

    454 454

    426 426

    361361

    243 302

    700 700

    10 16

    895 910

    840 840

    800 795

    30 36

    24 24

    35 41

    537537

    910910

    915915

    920920

    495 495

    469 469

    405405

    315 340

    800 800

    10 16

    1015 1025

    950 950

    905 900

    33 39

    24 24

    37 43

    605605

    10401040

    10451045

    10501050

    545 545

    519 519

    455455

    405 467

    900 900

    10 16

    1115 1125

    1050 1050

    1005 1000

    33 39

    28 28

    39 45

    671671

    11701170

    11751175

    11801180

    595 595

    569 569

    505505

    483 567

    1000 1000 1000

    6 10 16

    1175 1230 1255

    1120 1160 1170

    1080 1110 1115

    30 36 42

    28 28 28

    31 39 47

    739739739

    130013001300

    130513051305

    131013101310

    645 645 645

    619 619 619

    555555555

    475 575 764

    inch inch DN PN1) D k d4 d2 N b A L L2) L3) G E F

    appr. lb

    350 350

    10 16

    19.88 20.47

    18.11 18.50

    16.93 17.24

    0.87 1.02

    0.63 0.63

    1.22 1.38

    12.68 12.68

    21.65 21.65

    21.85 21.85

    22.05 22.05

    13.43 13.43

    12.32 12.32

    9.84 9.84

    277.8 308.6

    400 400

    10 16

    22.24 22.83

    20.28 20.67

    18.98 19.29

    1.02 1.18

    0.63 0.63

    1.22 1.46

    14.57 14.57

    23.62 23.62

    23.82 23.82

    24.02 24.02

    14.45 14.45

    13.35 13.35

    10.83 10.83

    341.7 385.8

    500 500

    10 16

    26.38 28.15

    24.41 25.59

    23.03 24.02

    1.02 1.30

    0.79 0.79

    1.30 1.54

    16.02 16.02

    25.59 25.59

    25.79 25.79

    25.98 25.98

    15.87 15.87

    14.76 14.76

    12.20 12.20

    421.1 518.1

    600 600

    10 16

    30.71 33.07

    28.54 30.31

    26.97 28.54

    1.18 1.42

    0.79 0.79

    1.30 1.61

    18.46 18.46

    30.71 30.71

    30.91 30.91

    31.10 31.10

    17.87 17.87

    16.77 16.77

    14.21 14.21

    535.7 665.8

    700 700

    10 16

    35.24 35.83

    33.07 33.07

    31.50 31.30

    1.18 1.42

    0.94 0.94

    1.38 1.61

    21.14 21.14

    35.83 35.83

    36.02 36.02

    36.22 36.22

    19.49 19.49

    18.46 18.46

    15.94 15.94

    694.5 749.6

    800 800

    10 16

    39.96 40.35

    37.40 37.40

    35.63 35.43

    1.30 1.54

    0.94 0.94

    1.46 1.69

    23.82 23.82

    40.94 40.94

    41.14 41.14

    41.34 41.34

    21.46 21.46

    20.43 20.43

    17.91 17.91

    892.9 1.029.6

    900 900

    10 16

    43.90 44.29

    41.34 41.34

    39.57 39.37

    1.30 1.54

    1.10 1.10

    1.54 1.77

    26.42 26.42

    46.06 46.06

    46.26 46.26

    46.46 46.46

    23.43 23.43

    22.40 22.40

    19.88 19.88

    1.064.8 1.250.0

    1000 1000 1000

    6 10 16

    46.26 48.43 49.41

    44.09 45.67 46.06

    42.52 43.70 43.90

    1.18 1.42 1.65

    1.10 1.10 1.10

    1.22 1.54 1.85

    29.09 29.09 29.09

    51.18 51.18 51.18

    51.38 51.38 51.38

    51.57 51.57 51.57

    25.39 25.39 25.39

    24.37 24.37 24.37

    21.85 21.85 21.85

    1.047.2 1.267.7 1.684.3

    1) Other pressure stages upon request. 2) Grounding plate mounted on one side of flange in SS 1.4571 (316 Ti). Other materials upon request, L + 5 mm (0.20"). 3) With protection plates attached to flange on both sides. Grounding plate is not required L + 10 mm (0.39"). Also available with protective flanges in 1000 series. Installation length ≤ DN 80 L + 20 mm (0.79"), for DN 100 or higher L + 25 mm (0.98"). 4) Connecting dimensions acc. to EN1092-1. Pos: 27.7 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    18

    Pos: 27.8 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Maßzeichnungen/Durchflussmesser SE41/Maßzeichnung Flansch DN350-DN1000 (ASME) @ 3\mod_1157638448817_3101.doc @ 40138

    Meter dimensions acc. to ASME CL 150 Flange dimensions acc. to ASME CL 1501) Weight

    mm mm A L2) 3) E F G D k d4 d2 N b

    Inch ISO 13359

    old Install. length

    appr. kg

    14 16 18 20

    322 370 407 416

    550 600 686 762

    650 700 –

    780

    313 329 375 375

    250 275 310 310

    341 367 403 403

    534 597 635 699

    476 540 578 635

    413 470 533 584

    28.6 28.6 31.7 31.7

    12 16 16 20

    40 42 45 48

    178 225 230 263

    24 28

    469 537

    914 –

    850 910

    423 469

    361 405

    454 495

    813 837

    749 749

    692 762

    34.9 34.9

    20 20

    53 50

    327 385

    32 36 40

    605 671 739

    – – –

    1040 1170 1300

    519 569 619

    455 505 555

    545 595 645

    942 10571380

    900 10101210

    864 972

    1140

    22.2 25.4 56.0

    48 44 28

    51 57 63

    513 662

    1132 inch inch

    A L2) 3) E F G D k d4 d2 N b Inch ISO

    13359 old

    Install. length

    appr. lb

    14 16 18 20

    12.68 14.57 16.02 16.38

    21.65 23.62 27.01 30.00

    25.59 27.56

    – 30.71

    12.32 12.95 14.76 14.76

    9.84 10.83 12.20 12.20

    13.43 14.45 15.87 15.87

    21.02 23.50 25.00 27.52

    18.74 21.26 22.76 25.00

    16.26 18.50 20.98 22.99

    1.13 1.13 1.25 1.25

    0.47 0.63 0.63 0.79

    1.57 1.65 1.77 1.89

    392.4 496.0 507.1 579.8

    24 28

    18.46 21.14

    35.98 –

    33.46 35.83

    16.65 18.46

    14.21 15.94

    17.87 19.49

    32.01 32.95

    29.49 29.49

    27.24 30.00

    1.37 1.37

    0.79 0.79

    2.09 1.97

    720.9 848.8

    32 36 40

    23.82 26.42 29.09

    – – –

    40.94 46.06 51.18

    20.43 22.40 24.37

    17.91 19.88 21.85

    21.46 23.43 25.39

    37.09 41.61 54.33

    35.43 39.76 47.64

    34.02 38.27 44.88

    0.87 1.00 2.20

    1.89 1.73 1.10

    2.01 2.24 2.48

    1.131.0 1.459.5 2.495.6

    1) Other pressure stages upon request. Dimensions 28" or larger acc. to ASME B16.47 Series B. 2) Grounding plate mounted on one side of flange in SS 1.4571 (316 Ti). Other materials upon request, L + 5 mm (0.20"). 3) With protection plates attached to flange on both sides. Grounding plate is not required L + 10 mm (0.39"). Also available with protective flanges in 1000 series. Installation length ≤ 3" L + 20 mm (0.79"), for 4" or higher L + 25 mm (0.98"). Pos: 28 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    19

    Pos: 29 /Überschriften/1.1/1-spaltig/A - C/Bestellinformationen @ 2\mod_1139828409218_3101.doc @ 3181

    3.3 Ordering information Pos: 30 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Bestellinformationen/SE41F @ 3\mod_1157640360285_3101.doc @ 40348

    Information on 3A conformity: If 3A conformity is desired, please order model SE21 Fixed flange, liner thick PTFE, PTFE, PFA, ETFE Electromagnetic Flowmeter Variant digit No. 1 - 6 7 8 9 10 11 12 13 14FSM4000-SE41F Catalog No. SE41F-remote sensor with welded flangeLiner Material Meter SizePFA DN 3 1/10 in. P 0 3PFA DN 4 5/32 in. P 0 4PFA DN 6 1/4 in. P 0 6PFA DN 8 5/16 in. P 0 8PTFE DN 10 3/8 in. T 1 0PTFE DN 15 1/2 in. T 1 5PTFE DN 20 3/4 in. T 2 0PTFE DN 25 1 in. T 2 5PTFE DN 32 1-1/4 in. T 3 2PTFE DN 40 1-1/2 in. T 4 0PTFE DN 50 2 in. T 5 0PTFE DN 65 2-1/2 in. T 6 5PTFE DN 80 3 in. T 8 0PTFE DN 100 4 in. T 1 HPTFE DN 125 5 in. T 1 QPTFE DN 150 6 in. T 1 FPTFE DN 200 8 in. T 2 HPTFE DN 250 10 in. T 2 FPTFE DN 300 12 in. T 3 HPTFE DN 350 14 in. T 3 FPTFE DN 400 16 in. T 4 HPTFE DN 450 18 in. (only ASME CL 150) T 4 FPTFE DN 500 20 in. T 5 HPTFE DN 600 24 in. T 6 HThick-PTFE DN 25 1 in. F 2 5Thick-PTFE DN 32 1-1/4 in. F 3 2Thick-PTFE DN 40 1-1/2 in. F 4 0Thick-PTFE DN 50 2 in. F 5 0Thick-PTFE DN 65 2-1/2 in. F 6 5Thick-PTFE DN 80 3 in. F 8 0Thick-PTFE DN 100 4 in. F 1 HThick-PTFE DN 125 5 in. F 1 QThick-PTFE DN 150 6 in. F 1 FThick-PTFE DN 200 8 in. F 2 HThick-PTFE DN 250 10 in. F 2 FThick-PTFE DN 300 12 in. F 3 H

    Continued on next page1) Grounding electrodes available only for meter size DN 3 ... DN 300

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    20

    Electromagnetic Flowmeter Variant digit No. 1 - 6 7 8 9 10 11 12 13 14FSM4000-SE41F Catalog No. SE41F-remote sensor with welded flangeLiner Material Meter SizeETFE DN 25 1 in. E 2 5ETFE DN 32 1-1/4 in. E 3 2ETFE DN 40 1-1/2 in. E 4 0ETFE DN 50 2 in. E 5 0ETFE DN 65 2-1/2 in. E 6 5ETFE DN 80 3 in. E 8 0ETFE DN 100 4 in. E 1 HETFE DN 125 5 in. E 1 QETFE DN 150 6 in. E 1 FETFE DN 200 8 in. E 2 HETFE DN 250 10 in. E 2 FETFE DN 300 12 in. E 3 HETFE DN 350 14 in. E 3 FETFE DN 400 16 in. E 4 HETFE DN 450 18 in. (only ASME CL 150) E 4 FETFE DN 500 20 in. E 5 HETFE DN 600 24 in. E 6 HETFE DN 700 28 in. E 7 HETFE DN 800 32 in. E 8 HETFE DN 900 36 in. E 9 HETFE DN 1000 40 in. E 1 TMeasuring Electrodes Material Grounding Electrodes 1)Hastelloy C-4 (2.4610) Without HHastelloy B-3 (2.4600) Without BSST 1.4571 (316Ti) Without STitanium Without MTantalum Without TSST 1.4539 (904L) Without FPlatinum-Iridium Without PHastelloy C-4 (2.4610) With OHastelloy B-3 (2.4600) With NSST 1.4571 (316Ti) With ETitanium With ITantalum With QSST 1.4539 (904L) With RPlatinum-Iridium With G

    Continued on next page1) Grounding electrodes available only for meter size DN 3 ... DN 300

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    21

    Electromagnetic Flowmeter Variant digit No. 1 - 6 11 12 13 14 15 16 17 18FSM4000-SE41F Catalog No. SE41F-remote sensor with welded flangePressure Rating 2)PN 10 ISO laid length CPN 16 ISO laid length 3) DPN 25 ISO laid length EPN 40 Standard for DN 3 ... DN 80 ISO laid length FJIS K10 ISO laid length KASME CL 150 DN 8 >= 0,5 µS/cm and laid length max. 200 m

    Continued on next page2) Dimensions of the flanges per DIN 2501 / EN 1092-1, or ASME B16.5 or JISB2210-10K3) DN 65 / PN 16 with connection dimensions acc. EN 1092-1: Please order PN 404) Protection rings mounted on both sides and grounding ring

    mounted on one side to flange, SST 1.4571 (316Ti)5) Only with laid length 1000 series, ASME / DIN flanges,

    installation length = DN 100: L + 25 mm6) Material certificate for meter tube and flanges7) Sealing compound (optionally) D141B038U01

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    22

    Electromagnetic Flowmeter Variant digit No. 1 - 6 15 16 17 18 19 20 21 22FSM4000-SE41F Catalog No. SE41F-remote sensor with welded flangeName PlateGerman adhesive foil GEnglish adhesive foil EFrench adhesive foil FGerman SST plate JEnglish SST plate KFrench SST plate LDesign Level (Specified by ABB) *Laid LengthStandard AElectrode DesignStandard 1Conical head, SST 1.4539 (904L) (>= DN 10) 8) 2Swedish design, material 1.4571 (316Ti) (DN 50 ... DN 100) 9) 3Swedish design, material 1.4571 (316Ti) (DN 125 ... DN 250) 9) 3Swedish design, material Hastelloy C-4 (DN 50 ... DN 100) 9) 3Swedish design, material Hastelloy C-4 (DN 125 ... DN 250) 9) 3

    8) For application e.g. with high fat contents9) For pulp applications with high resin contents

    Related Transmitter FSM4000-S4

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    23

    Fixed flange, liner hard/soft rubber Electromagnetic Flowmeter Variant digit No. 1 - 6 7 8 9 10 11 12 13 14FSM4000-SE41F Catalog No. SE41F-remote sensor with welded flangeLiner Material Meter SizeHard rubber DN 15 1/2 in. H 1 5Hard rubber DN 20 3/4 in. H 2 0Hard rubber DN 25 1 in. H 2 5Hard rubber DN 32 1-1/4 in. H 3 2Hard rubber DN 40 1-1/2 in. H 4 0Hard rubber DN 50 2 in. H 5 0Hard rubber DN 65 2-1/2 in. H 6 5Hard rubber DN 80 3 in. H 8 0Hard rubber DN 100 4 in. H 1 HHard rubber DN 125 5 in. H 1 QHard rubber DN 150 6 in. H 1 FHard rubber DN 200 8 in. H 2 HHard rubber DN 250 10 in. H 2 FHard rubber DN 300 12 in. H 3 HHard rubber DN 350 14 in. H 3 FHard rubber DN 400 16 in. H 4 HHard rubber DN 450 18 in. (only ASME CL 150) H 4 FHard rubber DN 500 20 in. H 5 HHard rubber DN 600 24 in. H 6 HHard rubber DN 700 28 in. H 7 HHard rubber DN 800 32 in. H 8 HHard rubber DN 900 36 in. H 9 HHard rubber DN 1000 40 in. H 1 TSoft rubber DN 50 2 in. S 5 0Soft rubber DN 65 2-1/2 in. S 6 5Soft rubber DN 80 3 in. S 8 0Soft rubber DN 100 4 in. S 1 HSoft rubber DN 125 5 in. S 1 QSoft rubber DN 150 6 in. S 1 FSoft rubber DN 200 8 in. S 2 HSoft rubber DN 250 10 in. S 2 FSoft rubber DN 300 12 in. S 3 HSoft rubber DN 350 14 in. S 3 FSoft rubber DN 400 16 in. S 4 HSoft rubber DN 450 18 in. (only ASME CL 150) S 4 FSoft rubber DN 500 20 in. S 5 HSoft rubber DN 600 24 in. S 6 HSoft rubber DN 700 28 in. S 7 HSoft rubber DN 800 32 in. S 8 HSoft rubber DN 900 36 in. S 9 HSoft rubber DN 1000 40 in. S 1 T

    Continued on next page

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    24

    Electromagnetic Flowmeter Variant digit No. 1 - 6 10 11 12 13 14 15 16 17FSM4000-SE41F Catalog No. SE41F-remote sensor with welded flangeMeasuring Electrodes Material Grounding Electrodes 1)SST 1.4571 (316Ti) Without SHastelloy C-4 (2.4610) Without HHastelloy B-3 (2.4600) Without BTitanium Without MTantalum Without TSST 1.4539 (904L) Without FPlatinum-Iridium Without PHastelloy C-4 (2.4610) With OHastelloy B-3 (2.4600) With NSST 1.4571 (316Ti) With ETitanium With ITantalum With QSST 1.4539 (904L) With RPlatinum-Iridium With GPressure Rating 2)PN 10 ISO laid length CPN 16 ISO laid length 3) DPN 25 ISO laid length EPN 40 Standard for DN 3 ... DN 80 ISO laid length FJIS K10 ISO laid length KASME CL 150

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    25

    Electromagnetic Flowmeter Variant digit No. 1 - 6 15 16 17 18 19 20 21 22FSM4000-SE41F Catalog No. SE41F-remote sensor with welded flangeDesignWithout pre-amplifier >= 20 μS/cm 1With pre-amplifier type A 2

    Option >= 5 μS/cm and laid length max. 200 mWith pre-amplifier type B 4

    Option >= 0,5 µS/cm and laid length max. 200 mName PlateGerman adhesive foil GEnglish adhesive foil EFrench adhesive foil FGerman SST plate JEnglish SST plate KFrench SST plate LDesign Level (Specified by ABB) *Laid LengthStandard AElectrode DesignStandard 1Conical head, SST 1.4539 (904L) 5) 2

    5) For application e.g. with high fat contents

    Related Transmitter FSM4000-S4 Pos: 31 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    26

    Pos: 32 /Überschriften/1/M - O/Modell SE21_ @ 3\mod_1157709057953_3101.doc @ 40875

    4 Model SE21_ Pos: 33 /Überschriften/1.1/1-spaltig/S - U/Technische Daten @ 7\mod_1157704677334_3101.doc @ 40581

    4.1 Technical data Pos: 34 /==== Wechsel ein- auf zweispaltig ==== @ 0\mod_1130421847171_3101.doc @ 3828 Wechsel ein-auf zweispaltig Pos: 35 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Technische Daten/Messaufnehmer/Modell SE21_ @ 3\mod_1157640761823_3101.doc @ 40390

    Minimum Allowable Absolute Pressure Liner Nominal size

    DN POperation mbar abs

    at TOperating* °C

    PFA 3 … 100 (1/10 … 4“)

    0 ≤ 130 °C (266 °F)

    Peek/Torlon 1 …2 (1/25 … 1/12“)

    0 ≤ 120 °C (248 °F)

    1) Higher temperatures are allowed for CIP/SIP cleaning for limited time periods, see Table "Maximum Allowable Cleaning Temperature".

    Maximum Allowable Cleaning Temperature

    CIP-Cleaning Liner Tmax Tmax Minutes

    Tamb.

    Steam cleaning

    PFA / Peek

    150 °C (302 °F)

    60

    25 °C (77 °F)

    Liquid cleaning PFA / Peek / Torlon

    140 °C (284 °F)

    60 25 °C (77 °F)

    If the ambient temperature is > 25 °C (77 °F), then the difference must be subtracted from the max. cleaning temperature. Tmax – Δ °C, Δ °C = (TAmb - 25 °C) Maximum Allowable Temperature Shock

    Liner Temp Shock max. Temp. Diff. °C

    Temp. gradient °C/min

    PFA any any Peek, Torlon any any

    Maximum allowable ambient temperature as function of fluid temperature

    Tamb °C (°F)

    G00224

    -40

    60 (140)

    40 (104)

    -10(14)

    -10(14F) DN 1 ... DN 2

    DN

    1..

    .D

    N2

    90 (194) 120(248)

    130(266)

    -25 (-13)

    TMeasuring°C (°F)

    Fig. 22: Temperature graph The flowmeter sensor may not be isolated Fluid temperature DN 1 … DN 2 (1/25 ... 1/12") -10 … 120 °C (14 ... 248 °F), max. allowable cleaning temperature, see table

    Flowmeter material Lining Electrode material Electrode design

    Standard Options Standard Options PFA, Peek, Torlon

    Hast.-C4 (2.4610) (1.4539 [904 L] for pipe

    conn. and Tri-Clamp)

    Hast.-B3 (2.4600)

    SS 1.4539 (904 L)

    SS 1.4571 (316 Ti)

    Titanium, tantalum, platinum-

    iridium

    Flat head

    Pointed head

    (≥ DN 10) SS 1.4539

    (904 L)

    1/8" sanitary connectors always with 2 grounding electrodes in material for signal electrodes, standard. Process Connection Materials Process Connection Standard Option Flanges SS 1.4571 (316 Ti) on request Wafer design None Weld stubs SS 1.4404 (316 L) on request Threaded pipe connection SS 1.4404 (316 L) on request Tri-Clamp SS 1.4404 (316 L) on request External threads SS 1.4404 (316 L) on request 1/8" sanitary connectors SS 1.4571 (316 Ti) POM, brass,

    PVC Connection box - without/with

    preamplifier, type A - with preamplifier,

    type B

    SS 1.4301 (304) Al alloy, painted, paint coat frame: dark gray, RAL 7012 cover: light gray, RAL 9002

    Meter tube SS 1.4301 (304) – Cable gland Polyamide PVDF Flowmeter sensor housing

    SS 1.4301 (304) –

    Gasket material (internal)

    Process Connection

    Standard Option

    Wafer design None – Weld stubs Threaded pipe connection Tri-Clamp External threads

    EPDM (Ethylene-Propylene) with FDA approval, silicone with FDA approval (CIP-resistant, no oils or grease)

    Silicon with FDA approval (optional, resistant to oils and grease) PTFE with FDA approval (DN 3 ... 8)

    1/8" sanitary connector

    PTFE Viton (only in combination with PVC process connection)

    Flat housing gaskets Silicon (resistant to oil, grease)

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    27

    Storage Temperature -25 … 70 °C (-13 ... 158 °F) Protection Class per EN 60529 • IP 67 • IP 68 (option) Pipeline Vibration Following EN 60068-2-6 Transmitter - In the range of 10…55 Hz, max. deflection 0.15 mm Flowmeter sensor - In the range of 10…55 Hz, max. deflection 0.15 mm - In the range of 55…150 Hz, max. acceleration 2 g Materialload for meters with variable process connections / wafer flange SE21 DN 1 ... DN 100 (1/25 ... 4") Process connect. Liner PFA

    Nominal size DN

    PSmax [bar]

    TSmin TSmax

    Wafer design 3 … 50 (1/10 … 2“) 65 … 100

    (2 1/2 … 4“)

    40

    16

    -25 °C (-13 °F)

    130 °C (266 °F)

    Weld stubs 3 … 40 (1/10 … 1 1/2“)

    50; 80 (2“, 3“) 65, 100

    (2 1/2 … 4“)

    40

    16

    10

    -25 °C (-13 °F)

    130 °C (266 °F)

    Threaded pipe connection DIN 11851

    3 … 40 (1/10 … 1 1/2“)

    50; 80 (2“, 3“) 65, 100

    (2 1/2 … 4“)

    40

    16

    10

    -25 °C (-13 °F)

    130 °C (266 °F)

    Tri-clamp acc. to DIN 32676

    3 … 50 (1/10 … 2“) 65 … 100

    (2 1/2 … 4“)

    16

    10

    -25 °C (-13 °F)

    121 °C (250 °F)

    Tri-Clamp per ASME BPE 1

    3 ... 100 (1/10 ... 4“)

    10 -25 °C (-13 °F)

    130 °C (266 °F)

    External threads ISO 228

    3 … 25 (1/10 … 1“

    16

    -25 °C (-13 °F)

    130 °C (266 °F)

    1/8" sanitary connector

    1 … 2 (1/25 … 1/12“)

    10 -10 °C (14 °F)

    120 °C (248 °F)

    Material load for flange model SE21F Lining: PFA

    G00221

    PS[bar]

    TS

    PN 40

    PN 25

    PN 16

    PN 10

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120 130 *) [°C]

    -22 -4 14 32 50 68 86 104 122 140 158 176 194 212 230 248 266 *) [°F]

    PS[psi]

    0

    72.5

    145.0

    217.5

    290.0

    362.5

    435.0

    507.5

    580.0

    652.5

    Fig. 23: DIN-Flanges SS 1.4571 (316 Ti) to DN 100 (4") Liner PFA

    G00222

    PS[bar]

    TS

    CL 300

    CL 150

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    50

    55

    -30 -10 10 30 50 70 90 110 130 *) [°C]

    -22 14 50 86 122 158 194 230 266 *) [°F]

    PS[psi]

    72.5

    145.0

    217.5

    290.0

    362.5

    435.0

    507.5

    580.0

    652.5

    725.0

    697.5

    0

    Fig. 24: ASME flange SS 1.4571 (316 Ti) to DN 100 (4") JIS B2210-10K wafer flange

    Meter size DN

    Material PN TS PS [bar]

    32 … 100 (1¼ … 4“)

    SS 1.4404 (316 L) SS 1.4435 (316 L) SS 1.4301 (304)

    10 -40 … 130 °C (-40 … 266 °F)

    10

    Material load for flange model SE21W Lining: PFA wafer flange

    G00223

    PS[bar]

    TS

    PN 40/CL 300

    PN 25

    PN 16/CL 150

    PN 10

    0

    5

    10

    15

    20

    25

    30

    35

    40

    45

    -60 -50 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 120130 *) [°C]

    -76 -58 -40 -22 -4 14 32 50 68 86 140122140158 176194 212 230248266 *) [°F]

    PS[psi]

    0

    72.5

    145.0

    217.5

    290.0

    362.5

    435.0

    507.5

    580.0

    652.5

    Fig. 25 Higher temperatures are allowed for CIP/SIP cleaning for limited time periods, see Table "Maximum Allowable Cleaning Temperature". Pos: 36 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    28

    Pos: 37 /==== Wechsel zwei- auf einspaltig ==== @ 0\mod_1130421955859_3101.doc @ 3829

    Wechsel ein-auf zweispaltig Pos: 38.1 /Überschriften/1.1/1-spaltig/M - O/Maßzeichnungen @ 11\mod_1157707121639_3101.doc @ 40791

    4.2 Dimensional drawings Pos: 38.2 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Maßzeichnungen/Durchflussmesser SE21/Maßzeichnung Flansch SE21F, DN3-DN40 @ 3\mod_1157639602746_3101.doc @ 40243

    4.2.1 Model SE21F

    Stainless steel housing, flange acc. to DIN / EN 1092-1, DN 3 ... DN 40; ASME B16.5, 1/10 ... 1 1/2"

    G00229

    104 (4,09)

    L

    A

    FE

    G

    b

    80 (3,15)

    41 (1,61)

    k

    D

    FE

    G

    Ød

    4

    ØD

    Ød2

    71

    (2,8

    0)

    1

    2

    Fig. 26: Dimensions in mm (inch) 1 Cable gland M20 x 1.5 or NPT 2 Number of holes N

    Flange dimensions acc. to DIN / EN, liner PFA Weight mm DN PN

    L1) A D k d4 d2 b E F G appr. kg

    3 ... 83) 130 37 90 60 42 14 18 62 39 133 2.5 10, 15 200 37 90, 95 65 36 14 18 62 39 133 2.5

    20 200 42 105 75 41 14 20 66 43 137 2.5 25 200 54 115 85 54 14 20 73 48 144 3 32 200 62 140 100 64 14 20 78 53 149 4 40

    10 ... 40

    200 67 150 110 74 14 20 82 57 153 4.5 inch DN PN

    L1) A D k d4 d2 b E F G appr. lb

    3 ... 83) 5.12 1.46 3.54 2.36 1.65 0.55 0.71 2.44 1.54 5.24 5.5 10, 15 7.7 1.46 3.54, 3.74 2.56 1.42 0.55 0.71 2.44 1.54 5.24 5.5

    20 7.87 1.65 4.13 2.95 1.61 0.55 0.79 2.60 1.69 5.39 5.5 25 7.87 2.13 4.53 3.35 2.13 0.55 0.79 2.87 1.89 5.67 6.6 32 7.87 2.44 5.51 3.94 2.52 0.55 0.79 3.07 2.09 5.87 8.8 40

    10 ... 40

    7.87 2.64 5.91 4.33 2.91 0.55 0.79 3.23 2.24 6.02 9.9

    1) If a grounding plate is required, L + 3 mm (0.12"). With 2 grounding plates (protection plates) L + 6 mm (0.24"), material upon request. 2) Connecting dimensions acc. to EN1092-1 3) Connection flange DN 10 (3/8") 4) Connection flange 1/2"

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    29

    Flange dimensions acc. to ASME B16.5, liner PFA Weight

    mm Inch PN L1) A D k d4 d2 b E F G

    appr. kg

    1/10 ... 5/164) 130 37 88.9 60.3 42.0 15.9 18.0 62 39 133 2.5

    3/84), 1/2 200 37 88.9 60.3 34.8 15.9 12.6 62 39 133 2.5 3/4 200 42 98.4 69.8 42.9 15.9 14.2 66 43 137 2.5 1 200 54 108.0 79.2 50.8 15.9 15.8 73 48 144 3

    1 1/4 200 62 117.5 88.9 63.5 15.9 17.4 78 53 149 3 1 1/2

    CL 150

    200 67 127.0 98.6 73.0 15.9 19.0 82 57 153 3.5 1/10 ... 5/164) 130 37 95.2 66.7 42.0 15.9 18.0 62 39 133 2.5

    3/84), 1/2 200 37 95.2 66.7 34.8 15.9 15.8 62 39 133 2.5 3/4 200 42 117.5 82.5 42.9 19.0 17.4 66 43 137 2.5 1 200 54 123.8 88.9 50.8 19.0 19.0 73 48 144 3

    1 1/4 200 62 133.3 98.4 63.5 19.0 20.5 78 53 149 4 1 1/2

    CL 300

    200 67 155.6 114.3 73.0 22.2 22.1 82 57 153 4.5 inch Inch PN

    L1) A D k d4 d2 b E F G appr. lb

    1/10 ... 5/164) 5.12 1.46 3.50 2.37 1.65 0.63 0.71 2.44 1.54 5.24 5.5

    3/84), 1/2 7.87 1.46 3.50 2.37 1.37 0.63 0.50 2.44 1.54 5.24 5.5 3/4 7.87 1.65 3.87 2.75 1.69 0.63 0.56 2.60 1.69 5.39 5.5 1 7.87 2.13 4.25 3.12 2.00 0.63 0.62 2.87 1.89 5.67 6.6

    1 1/4 7.87 2.44 4.63 3.50 2.50 0.63 0.69 3.07 2.09 5.87 6.6 1 1/2

    CL 150

    7.87 2.64 5.00 3.88 2.87 0.63 0.75 3.23 2.24 6.02 7.7 1/10 ... 5/164) 5.12 1.46 3.75 2.63 1.65 0.63 0.71 2.44 1.54 5.24 5.5

    3/84), 1/2 7.87 1.46 3.75 2.63 1.37 0.63 0.62 2.44 1.54 5.24 5.5 3/4 7.87 1.65 4.63 3.25 1.69 0.75 0.69 2.60 1.69 5.39 5.5 1 7.87 2.13 4.87 3.50 2.00 0.75 0.75 2.87 1.89 5.67 6.6

    1 1/4 7.87 2.44 5.25 3.87 2.50 0.75 0.81 3.07 2.09 5.87 8.8 1 1/2

    CL 300

    7.87 2.64 6.13 4.50 2.87 0.87 0.87 3.23 2.24 6.02 9.9

    1) If a grounding plate is required, L + 3 mm (0.12"). With 2 grounding plates (protection plates) L + 6 mm (0.24"), material upon request. 2) Connecting dimensions acc. to EN1092-1 3) Connection flange DN 10 (3/8") 4) Connection flange 1/2" Pos: 38.3 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    30

    Pos: 38.4 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Maßzeichnungen/Durchflussmesser SE21/Maßzeichnung Flansch SE21F, DN50-DN100 @ 12\mod_1189600221421_3101.doc @ 121613

    Stainless steel housing, flange acc. to DIN / EN 1092-1, DN 50 ... DN 100; ASME B16.5, 2 ... 4"

    G00230

    A

    d2

    L

    EE

    G

    80 (3,15)

    41 (1,61)

    G

    b

    71

    (2,8

    0)

    1

    2

    Ød4

    ØD

    Fig. 27: Dimensions in mm (inch) 1 Cable gland M20 x 1.5 or NPT 2 Number of holes N

    Flange dimensions acc. to DIN / EN, liner PFA Weight mm DN PN

    L1) A D k d4 d2 N b E G appr. kg

    50 10 ... 40 200 100 165 125 104 18 4 24 90 161 8 652) 10 ... 16

    25 ... 40 200 200

    107 107

    185 185

    145 145

    124 124

    18 18

    4 8

    26 26

    105 105

    176 176

    10 10

    80 10 ... 40 200 107 200 160 139 18 8 28 114 185 12 100 10 ... 16

    25 ... 40 250 250

    159 159

    220 235

    180 190

    161 167

    18 22

    8 8

    24 28

    128 128

    199 199

    18 18

    inch DN PN L1) A D k d4 d2 N b E G

    appr. lb

    50 10 ... 40 7.87 3.94 6.50 4.92 4.09 0.71 0.16 0.94 3.54 6.34 17.6 652) 10 ... 16

    25 ... 40 7.87 7.87

    4.21 4.21

    7.28 7.28

    5.71 5.71

    4.88 4.88

    0.71 0.71

    0.16 0.31

    1.02 1.02

    4.13 4.13

    6.93 6.93

    22.0 22.0

    80 10 ... 40 7.87 4.21 7.87 6.30 5.47 0.71 0.31 1.10 4.49 7.28 26.5 100 10 ... 16

    25 ... 40 9.84 9.84

    6.26 6.26

    8.66 9.25

    7.09 7.48

    6.34 6.57

    0.71 0.87

    0.31 0.31

    0.94 1.10

    5.04 5.04

    7.83 7.83

    39.7 39.7

    1) If a grounding plate is required, L + 3 mm (0.12"). With 2 grounding plates (protection plates) L + 6 mm (0.24"), material upon request. 2) For DN 65/PN 16 acc. to EN1092-1 please order PN 40.

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    31

    Flange dimensions acc. to ASME B16.5, liner PFA Weight mm Inch PN

    L1) A D k d4 d2 N b E G appr. kg

    2 200 100 152 121 99 19 4 23 90 161 8 2 1/2 200 107 178 140 118 19 4 26 105 176 10

    3 200 107 191 152 131 19 4 28 114 185 12 4

    CL 150

    250 159 229 190 171 19 8 28 128 199 18 2 200 100 165 127 102 19 8 26 90 161 8

    2 1/2 200 107 191 149 124 22 8 29 105 176 10 3 200 107 210 168 143 22 8 32 114 185 12 4

    CL 300

    250 159 254 200 177 22 8 36 128 199 18 inch Inch PN

    L1) A D k d4 d2 N b E G appr. lb

    2 7.87 3.94 5.98 4.76 3.90 0.75 0.16 0.91 3.54 6.34 17.6 2 1/2 7.87 4.21 7.01 5.51 4.65 0.75 0.16 1.02 4.13 6.93 22.0

    3 7.87 4.21 7.52 5.98 5.16 0.75 0.16 1.10 4.49 7.28 26.5 4

    CL 150

    9.84 6.26 9.02 7.48 6.73 0.75 0.31 1.10 5.04 7.83 39.7 2 7.87 3.94 6.50 5.00 4.02 0.75 0.31 1.02 3.54 6.34 17.6

    2 1/2 7.87 4.21 7.52 5.87 4.88 0.87 0.31 1.14 4.13 6.93 22.0 3 7.87 4.21 8.27 6.61 5.63 0.87 0.31 1.26 4.49 7.28 26.5 4

    CL 300

    9.84 6.26 10.00 7.87 6.97 0.87 0.31 1.42 5.04 7.83 39.7

    1) If a grounding plate is required. L + 3 mm (0.12"). With 2 grounding plates (protection plates) L + 6 mm (0.24"), material upon request. Pos: 38.5 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    32

    Pos: 38.6 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Maßzeichnungen/Durchflussmesser SE21/Maßzeichnung Zwischenflansch SE21W, DN3-DN100 @ 3\mod_1157639606021_3101.doc @ 40264

    4.2.2 Model SE21W

    Stainless steel housing, wafer flange DN 3 ... DN 100 (1/10 ... 4") DN 3 ... DN 40 (1/10 ... 1½")

    G00231

    A

    80 (3,15)

    C

    A*

    B

    G EF

    L

    J

    DN 3 ... DN 8 (1/10 ... 5/16”)

    41 (1,61)

    4 x Ø5,5 (0,22”)

    37

    (1,4

    6)

    71

    (2,8

    0)

    1

    ØD

    13.6

    ØD

    i

    ØC

    ØD

    2

    3

    4

    DN 50 ... DN 100 (2 ... 4")

    G00459

    G EF

    A*L

    ØD

    ØD

    i

    ØC

    80 (3,15)

    41 (1,61)

    71

    (2,8

    0)

    1

    Fig. 28: Dimensions in mm (inch) 1 Cable gland Pg 13.5 or NPT 2 Pattern for axial holes

    3 Hole pattern 4 Mounting bracket (optional)

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    33

    Wafer flange dimensions Weight

    mm DN (inch) PN L1) A* A B C ØC ØDi ØD E F G J

    appr. kg

    3 (1/10) 4 (5/32) 6 (1/4)

    8 (5/16) 10 (3/8) 15 (1/2)

    68

    64

    37

    28

    50

    42

    3 4 6 8

    10 13

    45

    62

    39

    172

    28

    32

    1.5

    20 (3/4) 78 74 42 28 50 50 18 54 66 43 205 32 2.0 25 (1) 90 86 42 46 70 59 24 63 73 48 219 32 2.0

    32 (1 1/4) 98 94 42 46 70 69 30 73 78 53 229 32 2.5 40 (1 1/2) 103 99 42 46 70 77 36 82 82 57 237 32 3.0

    50 (2)

    10 ... 40 CL150 CL300

    JIS

    117 112 – 60 110 95 47 100 90 50 213 – 4.0 65 (2 1/2) 103 99 – 60 110 111 62 116 105 58 235 – 4.5

    80 (3) 103 99 – 60 110 128 74 133 114 67 252 – 6.5 100 (4)

    10 ... 16 CL150

    JIS 133 129 – 60 110 155 96 160 128 80 279 – 8.5

    inch DN (inch) PN L1) A* A B C ØC ØDi ØD E F G J

    appr. lb

    3 (1/10) 4 (5/32) 6 (1/4)

    8 (5/16) 10 (3/8) 15 (1/2)

    2.68

    2.52

    1.46

    1.10

    1.97

    1.65

    0.12 0.16 0.24 0.31 0.39 0.51

    1.77

    2.44

    1.54

    6.77

    1.10

    1.26

    3.3

    20 (3/4) 3.07 2.91 1.65 1.10 1.97 1.97 0.71 2.13 2.60 1.69 8.07 1.26 4.4 25 (1) 3.54 3.39 1.65 1.81 2.76 2.32 0.94 2.48 2.87 1.89 8.62 1.26 4.4

    32 (1 1/4) 3.86 3.70 1.65 1.81 2.76 2.72 1.18 2.87 3.07 2.09 9.02 1.26 5.5 40 (1 1/2) 4.06 3.90 1.65 1.81 2.76 3.03 1.42 3.23 3.23 2.24 9.33 1.26 6.6

    50 (2)

    10 ... 40 CL150 CL300

    JIS

    4.61 4.41 – 2.36 4.33 3.74 1.85 3.94 3.54 1.97 8.39 – 8.8 65 (2 1/2) 4.06 3.90 – 2.36 4.33 4.37 2.44 4.57 4.13 2.28 9.25 – 9.9

    80 (3) 4.06 3.90 – 2.36 4.33 5.04 2.91 5.24 4.49 2.64 9.92 – 14.3 100 (4)

    10 ... 16 CL150

    JIS 5.24 5.08 – 2.36 4.33 6.10 3.78 6.30 5.04 3.15 10.98 – 18.7

    1) Installation lengths with 2 ground plates L + 3 mm (0.12")

    Mounting bracket (optional) With mounting bracket, combined height + 37 mm (1.46") DN 3 ... DN 40 (1/10 ... 1½"), + 10.5 mm (0.41") DN 50 ... DN 100 (2 ... 4"). Pos: 38.7 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    34

    Pos: 38.8 /Technische Daten / Datenblatt/Durchfluss/FSM4000/Maßzeichnungen/Durchflussmesser SE21/Maßzeichnung Variabler Prozessanschluss SE21_, DN3-DN100 @ 3\mod_1157639609055_3101.doc @ 40285

    4.2.3 Model SE21_

    Variable process connection DN 3 ... DN 40 (1/10 ... 1½")

    G00232

    41 (1,61)

    C

    3 (0,12)

    4 x Ø5.5

    B

    A

    G

    EF

    104 (4,09)

    80 (3,15)

    ØD

    71

    (2,8

    0)

    37

    (1,4

    6)

    80 (3,15)1

    2

    3

    45

    DN 50 ... DN 100 (2 ... 4")

    G00233

    3 (0,12)

    (2 1/2 ... 4)

    DN 65...100

    B

    104 (4,09)

    G

    EF

    4 x Ø5.5 4 x Ø5.5C

    DN 50 (2)

    ØD

    41 (1,61)

    80 (3,15)80 (3,15)

    71

    (2,8

    0)

    10,5

    (0,4

    1)

    1

    6

    25

    4

    3

    Fig. 29: Dimensions in mm (inch) 1 Cable gland Pg 13.5 or NPT 2 Pattern for axial holes 3 Mounting bracket (optional)

    4 Hole pattern 5 LPipe 6 Number of holes N

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    35

    Variable process connection Weight

    mm DN (inch) A ØD B C E F G LPipe N

    appr. kg1)

    3 ... 10 (1/10 ... 3/8) 37 44 28 50 62 39 172 85 – 1.5 15 (1/2) 37 44 28 50 62 39 172 85 – 1.5 20 (3/4) 42 63 28 50 66 43 180 90 – 2.0 25 (1) 42 63 46 70 73 48 192 105 – 2.0

    32 (1 1/4) 42 78 46 70 78 53 202 120 – 2.5 40 (1 1/2) 42 78 46 70 82 57 210 125 – 3.0

    50 (2) – 100 60 110 90 50 211 128 8 4.0 65 (2 1/2) – 116 60 110 105 58 234 114 10 4.5

    80 (3) – 133 60 110 114 67 252 114 6 6.5 100 (4) – 160 60 110 128 80 279 114 6 9.0

    inch DN (inch) A ØD B C E F G LPipe N

    appr. lb1)

    3 ... 10 (1/10 ... 3/8) 1.46 1.73 1.10 1.97 2.44 1.54 6.77 3.35 – 3.3 15 (1/2) 1.46 1.73 1.10 1.97 2.44 1.54 6.77 3.35 – 3.3 20 (3/4) 1.65 2.48 1.10 1.97 2.60 1.69 7.09 3.54 – 4.4 25 (1) 1.65 2.48 1.81 2.76 2.87 1.89 7.56 4.13 – 4.4

    32 (1 1/4) 1.65 3.07 1.81 2.76 3.07 2.09 7.95 4.72 – 5.5 40 (1 1/2) 1.65 3.07 1.81 2.76 3.23 2.24 8.27 4.92 – 6.6

    50 (2) – 3.94 2.36 4.33 3.54 1.97 8.31 5.04 0.31 8.8 65 (2 1/2) – 4.57 2.36 4.33 4.13 2.28 9.21 4.49 0.39 9.9

    80 (3) – 5.24 2.36 4.33 4.49 2.64 9.92 4.49 0.24 14.3 100 (4) – 6.30 2.36 4.33 5.04 3.15 10.98 4.49 0.24 19.8

    1) For process connection weights see page 36

    Mounting bracket (optional) With mounting bracket, combined height +37 mm (1.46") DN 3 ... DN 40 (1/10 ... 1½"), +10.5 mm (0.41") DN 50 ... DN 100 (2 ... 4"). Pos: 38.9 /======= Seitenumbruch ======== @ 0\mod_1126532365768_3101.doc @ 3830

  • Electromagnetic Flowmeter FSM4000 D184S073U02

    36

    Pos: 38.10 /Technische Daten / Datenblatt/Durchfluss/FXE4000/Maßzeichnungen/Durchflussmesser DE21-23/Maßzeichnung Adapter für variable Anschlüsse @ 8\mod_1175156265359_3101.doc @ 75146

    4.2.4 Adapter for variable process connections DN 3 ... DN 100 (1/10 ... 4")

    G00072

    L

    Di

    3

    1

    4

    2

    L

    Di

    Da

    Da

    L

    L

    R

    a

    Fig. 30

    1 Weld stubs 2 Threaded pipe connection DIN 11851

    3 Tri-Clamp 4 External threads

    Weld stubs Weightmm

    ISO 2037 DIN 11850 SMS DIN 2463 ISO 1127 DN (inch) Ø Di Ø Da Ø Di Ø Da Series Ø Di Ø Da Ø Di Ø Da Ø Di Ø Da Series L

    kg

    3 ... 10 (1/10 ... 3/8) 10.0 12.0 10 13 2 - - 10.3 13.5 10.3 13.5 1 127 0.4 15 (1/2) 15.2 17.2 16 19 2 - - 18.1 21.3 18.1 21.3 1 127 0.4 20 (3/4) 19.3 21.3 20 23 2 - - 23.7 26.9 23.7 26.9 1 132 0.7 25 (1) 22.6 25.0 26 29 2 22.6 25.0 25.0 28.0 23.7 26.9 1 149 0.7

    32 (1 1/4) 31.3 33.7 32 34 1 - - 32.0 35.0 30.5 33.7 1 166 1.0 40 (1 1/2) 35.6 38.0 38 41 2 35.6 38.0 36.8 40.0 39.0 42.2 1 171 1.0

    50 (2) 48.6 51.0 50 54 3 48.6 51.0 49.0 52.0 47.8 51.0 2 173 1.0 65 (2 1/2) 60.3 63.5 66 70 2 60.3 63.5 66.0 70.0 66.0 70.0 2 165 1.4

    80 (3) 72.9 76.1 81 85 2 72.9 76.1 81.0 85.0 72.9 76.1 1 169 2 100 (4) 97.6 101.6 100 104 2 100.0 104.0 100.0 104.0 97.6 101.6 2 199 3

    inch ISO 2037 DIN 11850 SMS DIN 2463 ISO 1127 DN (inch)

    Ø Di Ø Da Ø Di Ø Da Series Ø Di Ø Da Ø Di Ø Da Ø Di Ø Da Series L lb

    3 ... 10 (1/10 ... 3/8) 0.39 0.47 0.39 0.51 2 - - 0.41 0.53 0.41 0.53 1 5.00 0.9 15 (1/2) 0.60 0.68 0.63 0.75 2 - - 0.71 0.84 0.71 0.84 1 5.00 0.9 20 (3/4) 0.76 0.84 0.79 0.91 2 - - 0.93 1.06 0.93 1.06 1 5.20 1.5 25 (1) 0.89 0.98 1.02 1.14 2 0.89 0.98 0.98 1.10 0.93 1.06 1 5.87 1.5

    32 (1 1/4) 1.23 1.33 1.26 1.34 1 - - 1.26 1.38 1.20 1.33 1 6.54 2.2 40 (1 1/2) 1.40 1.50 1.50 1.61 2 1.40 1.50 1.45 1.57 1.54