Text of D184S073U02 Electromagnetic Flowmeter · PDF fileElectromagnetic Flowmeter FSM4000...

  • Level 0: Information

    Data SheetD184S073U02

    Function Electromagnetic flowmeters ca

    measure the flowrate of liquids,sludges with an electrical condu(opt. 0.5 S/cm).

    Applications The SM4000 is specially design

    pulp & paper and food & beverato measure pulp stocksflows, faphase liquids, mining slurries anpump application).

    Instrument Advantages Digital Signal Processing (DSP)

    and accuracy in both flow direcstability.

    Integrated diagnostic tools incluwith the error analysis displayedcontact output for increased op

    Easy to use menudriven operaapplication the configuration. Edisplay is backlighted.

    Important Instrument Featu flowmeter primary designed pe diameter range from DN 1 to D accuracy < 0.5 of rate fluid temperatures 40 C to 13 Hygienic Certification 3A, FML, liners, PFA, PTFE, hard rubber standardized installation lengths Power supply voltage AC/DC

    FieldIT

    Electromagnetic Flowmeter FSM4000

    n be used to accurately slurries, pastes and ctivity of at least 20 S/cm

    ed to measure liquids in the ge industry. It can be used st changing process, two d pulsating flows (piston

    assures long term stability tions with absolute zero

    ding system monitoring and signalled over a erational reliability.ting structure for asy to read the fullgraphic

    resr PEDGuideline 97/23 ECN 1000 [1/25 to 40]

    0 C (opt. 180 C) EHEDG

    for DIN or ANSI flanges

  • Electromagnetic Flowmeter FSM4000D184S073U02

    Accuracy, Reference Conditions and Operating Principle

    Reference Conditions per EN 29104

    Fluid Temperature

    20 C 2 K

    Ambient Temperature

    20 C 2 K

    Supply Power

    Nominal voltage per name plate UN 1 %

    Reference installation conditions

    Upstream > 10 x D, Downstream > 5 x D, D = nominal size of the flowmeter primary

    Warm-up Time

    30 min

    Analog Output Effects

    Same as pulse output plus 0.1 % of rate 0.01 mA

    Operating PrincipleFaradays Laws of Induction form the basis for the electromagnetic flowmeters. It states that a voltage is induced in a conductor as it moves through a magnetic field.This principle is applied to a conductive fluid which flows through a magnetic field generated perpendicular to the flow direction (see Schematic).The voltage induced in the fluid is maesured at two electordes, installed diametrically opposed. This signal voltage UE is proportional to the magnetic induction B, the electrode spacing D and the average flow velocity v.Noting that the magnetic induction B and the electrode spacing D are constants, a proportionality exists between the signal voltage UE and the average flow velocity v. The equation for the volume flow shows that the signal voltage UE is linear and proportional to the volume flowrate.The induced signal voltage is processed in the converter into scaled, analog and digital signals.

    0

    0

    5

    0.5

    10

    1

    20

    2

    90

    9

    100 %

    10

    Acc

    urac

    y

    %

    Q

    mvs0.5

    Range max

    789

    6

    54321

    0.5

    Pulse Output Q> 0.05 Rangemax 0.5 % of rateQ< 0.05 Rangemax 0.00025 Rangemax

    Fig. 1 Accuracy

    UE

    y

    z

    x

    BD

    E

    v

    Magnet Coil

    Meter Tube inElectrode Plane

    Signal electrode

    Signal voltage

    UE = Signal voltage B = Magnetic induction D = Electrode spacing v = Average flow velocity qv = Volume flowrate

    UE ~

    qv =

    UE ~ qv

    B D v

    D2 4

    v

    Fig. 2 Electromagnetic Flowmeter Schematic

    2

  • Electromagnetic Flowmeter FSM4000D184S073U02

    Overview, Flowmeter Primary and Converter Design

    Weld stubs

    Pipe fittingFood industry fitting

    Tri-Clamp

    External threads

    Rigid Flanges Rigid FlangesWafer DesignVariable Connections

    DN 3DN 40 1/1011/2

    DN 50DN 100 24

    DN 3DN 40 1/1011/2

    DN 50DN 100 2 4

    Connection Types

    Additional, see Dimensions, Others upon request

    Accuracy 0.5 % of rateFlowmeter primary hsg. material Complete stainless steel housing Series 2000 Alum. Series 4000

    Flowmeter PrimaryModel Number SE21* SE21F SE21W SE41F

    Process Connections DN Inch PN * DN PN DN Inch PN PNWafer Design 3100 1/104 W 350 1/102 1040

    65100 21/24 1016

    Flanged DIN 2501 3100 1/104 F 3100 1040 DN3DN1000 1040Flanged ASME B16.5 3100 1/104 F 1/104150300 CL/JIS 350 1/102 CL300/JIS

    65100 21/24 CL150/JIS1/1040 CL150 1/1012 CL 300

    Food Industry Fitting DIN 11851 340 1/101 1/2 40 S 50, 80 2, 3 16 S 65, 100 2 1/2, 4 10 S

    Weld stubs DIN 11850 340 1/101 1/2 40 R 50, 80 2, 3 16 R 65, 100 2 1/2, 4 10 R

    Weld stubs DIN 2463 340 1/101 1/2 40 Q 50, 80 2, 3 16 Q 65, 100 2 1/2, 4 10 Q

    Weld stubs ISO 2037 2540 11 1/2 40 P 50, 80 2, 3 16 P 65, 100 2 1/2, 4 10 P

    TriClamp DIN 32676 350 1/102 16 T 65, 100 2 1/24 10 T

    External threads ISO 228 325 1/101 10 E 1/8 Sanitary connectors 12 1/251/12 10 B Liner PEEK, Torlon (DN 2 [1/12])PFA PFA Hard rubber, soft rubber,

    PTFE, PFA, othersConductivity 20 S/cm Option 0.5 S/cmElectrodes SST No. 1.4571 [316Ti], 1.4539, Hastelloy B2/C4, PlatinumIridium, Tantalum, TitaniumProcess connection material SST1.4404[316L] SST No. 1.4571 [316Ti] Steel,SSTNo.1.4571[316Ti]Protection Class per EN 60529 IP 67/ IP 68 IP 67 / IP 68 IP 67/ IP 68 IP 67 / IP 68Fluid temperature 25 to 130 C 40 to 130 C 25 to 130 C 25 to 130 C / 180 C

    ApprovalsHygienic & sterile requirements CIP/SIPcapable FML, 3A, EHEDG CIPcapable

    ConverterModel Number S4Supply power 85 253 V AC, 24 V AC/DCCurrent output standard 0/210 mA, 0/420 mAPulse output, 1channel std. active (24 V), optocoupler (220 mA)Ext. Zero return yesExt. Totalizer reset yesForward/reverse metering yesCommunication HARTProtocol (PROFIBUS PA, FF in preparation)Fluid monitor std. yes, from DN 10 [3/8] and 20 S/cmDetection empty pipe yesLocal indicator/totalizer yesAuto. density correction yes, manual entry (totalize and indicate in mass units)Protection Class / EN 60529 IP 67, NEMA 4XHousing Field mount housing

    3

  • Electromagnetic Flowmeter FSM4000D184S073U02

    Specifications: Flowmeter Primary

    Flow Ranges, Meter Sizes and Pressure Ratings

    Information:

    When a preamplifier is installed for low conditivity applications and the fluid has a high r (e.g. demineralized water r = 78) the fluid velocity is limited < 1 m/s.

    Flange Designs and Pressure Ratings

    Other meter sizes, press. ratings, temperature classes upon request.

    Designs

    Meter tube

    Stainless steel No. 1.4301 [304]

    DN 3 to DN 300 [1/10 to 12]

    Two piece housing: Cast Alum., painted1)

    Flanges

    Steel, zinc plated, standard Stn. stl 1.4571[316Ti] ( DN15[1/2] standard)

    DN 350 to DN 1000 [14 to 40]

    Steel, welded design, painted1)

    Flanges

    Steel, painted, standard,stn. stl. 1.4571[316Ti]

    Connection Box

    Body: RAL 70122)

    Cover: RAL 90021)

    1) Paint coat 80 m thick, RAL 9002 (white grey), painting see page 8 2) Paint coat 80 m thick, RAL 7012 (Basalt grey)

    Meter Size

    Dn Inch

    Std. Pressure Rating

    PN

    Min. Flow RangeFlow Velocity0 to 0.5 m/s

    Max. Flow RangeFlow Velocity0 to 10 m/s

    1 1/25 1.5 1/17 2 1/12

    101010

    0 to 0.03 l/min 0 to 0.06 l/min 0 to 0.1 l/min

    0 to 0.6 l/min 0 to 1.2 l/min 0 to 2 l/min

    3 1/10 4 5/32 6 1/4

    404040

    0 to 0.2 l/min 0 to 0.4 l/min 0 to 1 l/min

    0 to 4 l/min 0 to 8 l/min 0 to 20 l/min

    8 5/16 10 3/8 15 1/2

    404040

    0 to 1.5 l/min 0 to 2.25 l/min 0 to 5 l/min

    0 to 30 l/min 0 to 45 l/min 0 to 100 l/min

    20 3/4 25 1

    4040

    0 to 7.5 l/min 0 to 10 l/min

    0 to 150 l/min 0 to 200 l/min

    32 11/440 11/2

    4040

    0 to 20 l/min 0 to 30 l/min

    0 to 400 l/min 0 to 600 l/min

    50 2 65 21/2 80 3

    404040

    0 to 3 m3/h 0 to 6 m3/h 0 to 9 m3/h

    0 to 60 m3/h 0 to 120 m3/h 0 to 180 m3/h

    100 4 125 5 150 6

    161616

    0 to 12 m3/h 0 to 21 m3/h 0 to 30 m3/h

    0 to 240 m3/h 0 to 420 m3/h 0 to 600 m3/h

    200 8 250 10 300 12

    10/1610/1610/16

    0 to 54 m3/h 0 to 90 m3/h 0 to 120 m3/h

    0 to 1080 m3/h 0 to 1800 m3/h 0 to 2400 m3/h

    350 14 400 16 450 18 500 20

    10/1610/16Cl150

    10

    0 to 165 m3/h 0 to 225 m3/h 0 to 300 m3/h 0 to 330 m3/h

    0 to 3300 m3/h 0 to 4500 m3/h 0 to 6000 m3/h 0 to 6600 m3/h

    600 24 700 28 800 32

    101010

    0 to 480 m3/h 0 to 660 m3/h 0 to 900 m3/h

    0 to 9600 m3/h 0 to 13200 m3/h 0 to 18000 m3/h

    900 36 100040

    1010

    0 to 1200 m3/h 0 to 1350 m3/h

    0 to 24000 m3/h 0 to 27000 m3/h

    Meter Size Flanges Material Press. Rating PED

    3 251/10 1

    DINASME

    JIS

    SS1.4571[316Ti]or Steel

    40 barCL 150, CL 300

    10 bar

    SEPArt.3Par. 3

    3211/4

    DINASME

    JIS

    SS1.4571[316Ti]or Steel

    40 barCL 150, CL 300

    10 bar

    Con

    form

    ity E

    valu

    atio

    n pe

    r C

    ateg

    ory

    III, M

    odul

    e B

    1 +

    D, F

    luid

    Gro

    up 140

    11/2DIN

    ASMEJIS

    SS1.4571[316Ti]or Steel

    40 barCL 150, CL 300

    10 bar

    502

    DINASME

    JIS

    SS1.4571[316Ti]or Steel

    40 barCL 150, CL 300

    10 bar

    6521/2

    DINASME

    JIS

    SS1.4571[316Ti]or Steel

    16, 40 barCL 150, CL 300

    10 bar

    803

    DINASME

    JIS

    SS1.4571[316Ti]or Steel

    40 barCL 150, CL 300

    10 bar

    1004

    DINASME

    JIS

    SS1.4571[316Ti]or Steel

    16, 40 barCL 150, CL 300

    10 bar

    1255