Upload
parvez-saif
View
520
Download
9
Embed Size (px)
Citation preview
7/24/2019 Daikin VRV Catalog 131014
1/84
NEXT GENERATION VRVFROM THE WORLD LEADER IN AIRCONDITIONING
Heat Pump - 50 Hz
DAIPL-12H
7/24/2019 Daikin VRV Catalog 131014
2/84
CONTROLSYSTEMS
SPECIFICATIONS
MAINFEATURES
p52
p34
p06
AIR TREATMENTEQUIPMENTLINEUP
OUTDOOR UNITCOMBINATIONS
OUTDOOR UNITLINEUP
p66
p47
p16
OPTION LIST
INDOOR UNITLINEUP
p48
p17INDE
X
7/24/2019 Daikin VRV Catalog 131014
3/84
WORLDS MOST ADVANCEDVRV IVAIRCONDITIONING SYSTEM WITH
INNOVATIVE VRT TECHNOLOGY.
FIRST LAUNCHED IN JAPAN IN 1982, THE DAIKIN VRV SYSTEM HAS BEEN EMBRACED BY THE
WORLD MARKETS FOR OVER THREE DECADES. NOW, WE AT DAIKIN INTRODUCE THE NEXT
GENERATION VRV IV SYSTEM TO REINFORCE OUR INDUSTRY LEADERSHIP. THE SYSTEM NOW
OFFERS AN ENHANCED LINE-UP TO MEET AN EVER WIDENING VARIETY OF NEEDS, WHILEIMPROVING ENERGY SAVINGS, COMFORT AND EASE OF INSTALLATION.
THE VRV IV IS THE MOST ADVANCED AIRCONDITIONING SYSTEM IN THE WORLD AND IS
IDEAL FOR LARGE AND SMALL SPACES.
ENHANCED
LINEUP
Up to 60 HP
ENERGYSAVING
Higher COP and
VRT technology
EASE OF
INSTALLATION
Compact and
Lightweight design
COMFORT
Lower operation
sound
ENERGY SAVING TECHNOLOGY FOR VRV SYSTEM
The new VRV IVsystem now features VRTtechnology. VRTautomatically adjusts refrigerant temperature to individual building
and climate requirement, thus further improving annual energy
efficiency and maintaining comfort. With this technology, running
costs are reduced.
VRT-VARIABLE REFRIGERANT TEMPERATURE
7/24/2019 Daikin VRV Catalog 131014
4/84
DAIKINTHE WORLD LEADER IN AIRCONDITIONING
EUROPE/MIDDLE EAST/AFRICA CHINA
Daikin AirconditioningCentral Europe
Daikin(China) Investment
Daikin AirconditioningShanghai
Xian Daikin QinganCompressor
DaikinEurope N.V.
Hui Zhou Daikin SunsAirconditioning
Daikin Device(Suzhou)
Daikin Fluoro CoatingShanghai
Daikin AirconditioningUK
Daikin FluorochemicalsChina
Daikin AirconditioningSpain
Daikin AirconditioningFrance
Daikin IndustriesCzech Republic
Daikin AirconditioningItaly
Daikin AirconditioningGermany
Daikin ChemicalFrance
AT DAIKIN WE ARE A LEADING INNOVATORAND PROVIDER OF ADVANCED, HIGH-QUALITY
AIRCONDITIONING SOLUTIONS FOR RESIDENTIAL,
COMMERCIAL AND INDUSTRIAL APPLICATIONS.
As World's No. 1 Airconditioning Company, we are
committed to delivering airconditioning solutions that
enhance the quality of life all around the world. We,
at Daikin Industries Ltd., are a diverse multinational
company, active in airconditioning, chemicals and oil
hydraulics, was established in 1924. With headquarters
at Osaka, Japan, our Daikin family has more than
51,000 members, working across 60 production base
units and 208 consolidated subsidiaries worldwide. As
the world's sole manufacturer that develops a long line
of products from refrigerants to airconditioners, we
advocate comfortable living on the strength of advanced
technologies.
We are present in USA, Europe and Russia, the Middle
East, Africa, Asia, Oceania and Middle-South America.
We aim to serve our customers in each of these markets byproviding optimal airconditioning products.2
7/24/2019 Daikin VRV Catalog 131014
5/84
Osaka
Tokyo
ProductionSite
Overseas
ASIA/OCEANIA
NORTH AMERICA/
CENTRAL & SOUTH AMERICA
Daikin IndustriesThailand
Daikin CompressorIndustries
Daikin America Daikin AC(Americas)
Daikin AirconditioningSingapore
Daikin Australia Daikin HoldingUSA
Daikin AirconditioningIndia
(Inside Umeda Center Building) Japan
3
7/24/2019 Daikin VRV Catalog 131014
6/84
EXPLORING NEW R&D FRONTIERS
AT DAIKIN, WE ARE CREATING VALUETHROUGH INNOVATIVE TECHNOLOGIES.
AS A GLOBAL INDUSTRY FRONTRUNNER,
WE ARE CARRYING OUT RESEARCH
AND DEVELOPMENT ON THE WORLDS
MOST ADVANCED AIRCONDITIONING
TECHNOLOGY.
Our strong R&D edge has helped us create
futuristic products that enrich peoples lives. As
symbolised by the VRV, Daikin has put forth a
multitude of products and varied technology
that have always been, and continue to be, at
the forefront of innovation.
To be able to offer such products and services
that delight and astound our customers, we
have constructed an advanced R&D architecture.
FORMATION OF A THREE-DIVISION SYSTEM
OF RESEARCH, IT, AND DEVELOPMENT TO
SUPPORT OUR SUPERIOR PRODUCTS.
To create more advanced functions and new
value, we have instituted specialised R&D
divisions: the Environmental Technology
Research Laboratory and the Solution Product
Development Centre. In combination with the
Product Development Group, each of the three
divisions work in close cooperation to precisely
ascertain the customers needs and to enable
commercialisation of products, incorporating
advanced technology that take the lead overour competitors.
4
7/24/2019 Daikin VRV Catalog 131014
7/84
THE SOLUTIONS PRODUCT DEVELOPMENT
CENTRE: INTEGRATING AIRCONDITIONERS
WITH IT
Keeping in mind the changes in business brought
in by the computerisation and networking
of society, we have integrated IT into our
airconditioners, including communication
technology, software technology and digital
control. We are initiating R&D that will offer new
system services - a comfortable environment
with superior energy savings by networking air
conditioners. Such a scenario will enable them toexchange information with service centres.
ENVIRONMENTAL TECHNOLOGY RESEARCH
LABORATORY: INTENSIVE RESEARCH ON
ENVIRONMENTALLY CONSCIOUS, ENERGY
SAVING AIRCONDITIONING TECHNOLOGY
Accelerating globalisation of our airconditioning
business and varied needs of customers
across geographies are increasing our
research challenges. We have established a
research laboratory devoted to the two fields
of airconditioning and the environment.
With our mission to promote energy savings
in airconditioners, we are engaged in R&D on
cutting-edge technologies. Our aim is to create
futuristic products from fundamental research
on motor inverters, and other areas to support
individual product development.
Going forward, we will elevate our technology
edge to achieve further business expansionglobally.
5
7/24/2019 Daikin VRV Catalog 131014
8/84
EXCELLENT OPERATIONAL
PERFORMANCE
New series with compact and lightweight design
6 HP-60 HP with 28 models lineup
320 kg
0.95 m2
Compact
Design
Normal (Space Saving) Type
20 HP Product WeightInstallation Space
Lineup
HP
Normal Type
ENHANCED LINEUP UP TO 60 HP
6
7/24/2019 Daikin VRV Catalog 131014
9/84
Higher Coefficient of Performance (COP)
*Cooling operation conditions: Indoor temp. of
27CDB, 19CWB, and outdoor temp. of 35CDB.
0
3
3.5
4
4.5
6 HP
8 HP
4.304.41CoolingOperationCOP
Compact & lightweight design
Highly-integrated VRV IVsystem offers compactoutdoor units to achievemaximum utilisation of the
installation space.
InstallationSpace
0.71 m2
Product
Weight195 kg
12 HP
12 HP
765mm930 mm
Improves heat exchangerefficency, helps reducedoperation sound.
Lower operation sound
Peak in outdoor temperaturePeak in outdoor temperaturePeak in outdoor temperature
Enable night modeEnable night modeEnable night mode
Outdoor PCB automatically memorises the time whenthe peak outdoor temperature appears. It enablesquiet operation mode after 8 h*1, and returns tonormal mode after it keeps this on for 9 h*2.
*1 8 h is the initial setting with 6 h or 10 h also available.*2 9 h is the initial setting with 8 h or 10 h also available.
Notes: This function is available in setting at site.
The operating sound in quiet operation mode is the actual valuemeasured by our company.
The relationship of outdoor temperature (load) and time shownabove is just an example.
Streamlined air grille
It promotes the discharge ofswirling airflow, furtherreducing thepressure loss.
Streamlined scroll fanThe sharp edge of each fan blade
has a certain curvature, reducingboth the vibration and the pressureloss.
Streamlined
scroll fan
Illustrated
fan
Operating
sound(dB)
Load
(%)
Capacity
(%) Night mode
min. 40 dB(A)
8 hrs
8:00
50
60
50
100
0
40
57
12:00 16:00 20:00 0:00 4:00 8:00
9 hrs
VRVIVVRVIV
6 HP 8 HP 10 HP 12 HP
55 56 57 59
Sound level(dB(A))
Quiet night-time operation function
Without increasing operation sound, advancedanalytic technologies are utilised to optimise fandesign, increase airflow rate and external staticpressure.
Large airflow, high static pressure andquiet technology
ENERGY SAVING
EASE OF INSTALLATION
COMFORT
7
7/24/2019 Daikin VRV Catalog 131014
10/84
VRT-VARIABLE REFRIGERANT
TEMPERATURE
STATE-OF-THE-ART ENERGY SAVING TECHNOLOGY FOR VRV SYSTEM
How is energy reduced?During cooling, the refrigerant evaporatingtemperature (Te) is raised to minimise thedifference with the condensing temperature.During heating, the condensing temperature (Tc) islowered to minimise the difference to theevaporating temperature. Compressors work less,
and this reduces power comsumption.
CompressorCompressor
(During cooling)
Evaporator
Condenser
Evaporating temperature raisedCompressor workload reduced
Indoor unitheat exchanger
CompressorCompressor
Evaporator
Condenser
Indoor unitheat exchanger
(During heating)
Condensing temperature lowered
Compressor workload reduced
Coolingload
&capacity
25%
100%
OutdoorTemp.
35C30C25C20C
Capacitychangesto matchheat load
Refrigerant cycle
Typical changes in evaporating temperature and COP depending on changing indoor load
OutdoorTemp.
VRT
Without VRT
Low
High
Low
High
35C30C25C20C
Refrigerantevapo
rating
temp.
/Te(C
)
Automatic control toadjust temperature
OutdoorTemp.
COP
35C30C25C20C
Without VRT
VRT
Low
High
Customise your VRV system for optimal annual efficiency
The new VRVIVsystem now features VRT technology.VRT automatically adjusts refrigerant temperature to individualbuilding and climate requirement, thus further improvingannual energy efficiency and maintaining comfort.With this excellent technology, running costs are reduced.
Required capacity changesas airconditioning loadchanges according tooutdoor temperature.
Energy efficiency isimproved withoutsacrificing comfort.
Automatic control adjustsevaporating temperatureto heat load change.
In case of fixed evaporatingtemperature, excessive cooling,thermo on-off loss, and otherinefficiencies occur.
8
7/24/2019 Daikin VRV Catalog 131014
11/84
Can boost capacity above 100% if needed.The refrigerant temperature can go lower in cooling (higher in heating)than the set minimum (maximum in heating).
Gives priority to very fast reaction speed. The refrigerant temperature goes down (or up in heating) fast to keep
the room setpoint stable.
Gives priority to fast reaction speed. The refrigerant temperature goes down (or up in heating) fast to keep
the room setpoint stable.
Gives priority to efficiency. The refrigerant temperature goes down (or up in heating) gradually giving
priority to the efficiency of the system instead of the reaction speed.
Mild
mode
Quick
mode
Powerfulmode
Variable Refrigerant TemperatureFixed RefrigerantTemperature
High Sensible Mode
Fixed target Te
Auto ModeFloating target Te/Tc depending on heat load
Basic ModeFixed Te/Tc - Standard control
(default setting on VRV IV)
Unable to change Te
Powerful ModePowerful Mode
Reaction speed Very Fast
Quick ModeQuick Mode
Reaction speed Fast
Mild ModeMild Mode
Reaction speed Medium
Eco ModeEco Mode
Energy saving priorityCapacity priority
40
35
30
25
20
15
0Mar. Jun. Sep. Dec.
Av. max. temp. Av. daily temp. difference
Av. min. temp.
(Typical example)
OutdoorTemp.(C)
VRT is particularly effective at night whentemperatures are low.
40
35
30
25
20
15
0Mar. Jun. Sep. Dec.
Av. max. temp.
Heatingperiod
Heatingperiod
Intermediateperiod
IntermediateperiodCooling period
Av. min. temp.
OutdoorTemp.(C)
Set temperature
Very Fast Time
30
Start ofcooling
25
FastMedium
IndoorTemp.(C)
VRT offers quicker cool downto shorten uncomfortable pull down time.
Mild
Quick
Powerful
Floating Te/Tc Fixed Te
(Typical example)
Fine control to match user preference available through mode selection
Recommended for use in these situations
Basic mode is selected to maintain optimal comfort.
VRT is selected to save energy and prevent excessive cooling or heating.
Cooling only regions having differencesin daily temperature.
Cooling/heating regions having periodsof mild outdoor temperatures.
VRT is particularly effective during the intermediate periods.
Selecting VRT enables operation to be optimised for
either energy efficiency or rapid cooling/heating.
9
7/24/2019 Daikin VRV Catalog 131014
12/84
MORE FLEXIBLE SYSTEM DESIGN
MORE OPTIONS FOR INSTALLATION LOCATION
The long piping length provides more design flexibility, which can match even large-sized buildings.
Long piping length
For connection of only VRV
indoor units
Conditions of VRV indoor unit connection capacity
Connection capacity at maximum is 200%.
Connection ratio
Note:
*1 For the FXFQ25LU, and FXVQ models, maximum connection ratio is 130% for the entire range of outdoor units.
If the operational capacity of indoor units is more than 130%, low airflow operation isenforced in all the indoor units.
*Refer to page 47 for outdoor unit combination details.
50%200%
Connection ratio
Single outdoor units
Double outdoor units
Triple outdoor units
FXDQ, FXMQ-P, FXAQ models
Applicable
VRV indoor units
200%
Other VRV indoor
unit models*1
200%
160%
130%Connection ratio =Total capacity index of the indoor units
Capacity index of the outdoor units
1. No special requirements up to 40 m. The maximum actual piping length can be 90 m, depending on conditions. Various conditions and requirements have to be metto allow utilisation of 90 m piping length.
2. When level differences are 50 m or more, the diameter of the main liquid piping size must be increased and connection ratio must be 80% to 130%. If the outdoor unitis above the indoor unit, a dedicated setting on the outdoor unit is required.
Maximum
allowablelevel difference
Maximumallowablepiping length
Between the outdoor unitsand the indoor units
Between the indoor units
Between the outdoor units (Multiple use)
Between the first indoor branch and the farthest indoor unit
Between the outdoor branch and the last outdoor unit
Total piping length
Refrigerant piping length
30m
5m
90m
q
s
r
r
a+b+c+d+e+f+g+h+i
a+f+g+h+i
f+g+h+i
k+p
165m 190m
1000m
10m 13m
Actualpiping length
Equivalentpiping lengthExample
LevelDifference
Example
If the outdoor unit is above.
If the outdoor unit is below.
p
q
k
First outdoor branch
fa
b
Firstindoor branch
Multiple use
*The rest of indoor units are the same as for single use.
90m*1
90m 2
Max.
30m
Max.
90m
165m
190m
1000m
Max. equivalent piping length
90m 2
Max. actual piping length
Max. total piping length
30mMax. level differencebetween the indoor units
Max. level differencebetween the outdoor unitsand the indoor units
a
i
s
r
hgf
edcbFirst indoor branch
Single use
Colours in the diagram above are merely for identifying pipes referenced with symbols such as a .
2
10
7/24/2019 Daikin VRV Catalog 131014
13/84
78.4 PaMore options in theopening/angle of louvreOutstanding heat dissipationeffect in both hierarchical andintensive arrangement
VRVIV outdoor unit has achieved highexternal static pressure up to 78.4 Pa,ensuring the efficient heat dissipation andstable operation of equipment in eitherhierarchical or intensive arrangement.
78.4 PaMore options in theopening/angle of louvreOutstanding heat dissipationeffect in both hierarchical andintensive arrangement
High external static pressure
11
7/24/2019 Daikin VRV Catalog 131014
14/84
RELIABLE AND STABLE SYSTEM
MULTIPLE ADVANCED FEATURES ENSURING MORE ACCURATE TESTOPERATION AND STABLE SYSTEM
Daikin VRVIVsystem incorporates a simplified and efficient test operation function, not only greatlyaccelerating the installation process, but effectively improving the field setting quality as well.
Efficient automatic test operation
Automatically checks the wirings betweenoutdoor units and indoor units to confirm
whether there is a defective wiring.
Confirms and corrects the actual pipinglength.
Automatically checks whether the stopvalve in each outdoor unit is in normalstatus to ensure the smooth operation ofairconditioning system.
Automatic check
Wiringcheck
Pipingcheck
Stop valve
check
SIMPLIFIED COMMISSIONING AND AFTER-SALES SERVICE
VRVIVsystem utilises the 7-segmentluminous digital tubes to display systemoperation information, enabling theoperational state to be visually displayedwhilst facilitating simplifiedcommissioning and after-sales service.
Function of information displayby luminous digital tube
The VRVconfigurator is an advanced software solutionthat allows for easy system configuration andcommissioning.
Less time is required on the roof configuring the outdoorunit.
Multiple systems at different sites can be managed inexactly the same way, thus offering simplifiedcommissioning for key accounts.
Initial settings on the outdoor unit can be easily retrieved.
VRVconfigurator
Simplifiedcommissioning
Retrieve initial
system settings
Displayssystemoperationinformationdirectly
Figures outsystemoperationinformation byreading lightemitting stateof differentdiodes, whichis bothinefficient and
fallible.
7-segment digital display Conventional LED display
12
7/24/2019 Daikin VRV Catalog 131014
15/84
OUTDOOR UNIT SEQUENCING TECHNOLOGY
DOUBLE BACKUP OPERATION FUNCTIONS RESPONDING RESILIENTLY TOVARIOUS UNEXPECTED SITUATIONS
Automatic sequencing operation
During start-up, the Daikin VRV IVunit sequencing operation will be automatically enabled toensure balanced operation of each outdoor unit to improve longevity of equipment and stable operation.
Stage 1 Stage 2 Stage 3
Priority: Priority: Priority:
AutomaticsequencingAutomatic
sequencingAutomatic
sequencingAutomatic
sequencing
Daikin VRVIVsystem boasts double backup operation functions, which can secure the use of airconditioners in this area to the greatest extent by emergently enabling double backup operation functionseven if failure occurs in a set of airconditioning equipment.In the event of a failure, emergency operation can be conveniently enabled to allow the remaining systemto operate in a limited fashion.
Double backup operation functions
Unit backup operation function
If malfunction occurs in an outdoor unit...Emergency operation can be conveniently set and enabled
by the remote controller for indoor unit (for systemscomposed of two or more outdoor units).
If malfunction occurs in a compressor...Emergency operation can be easily set andenabled by the outdoor unit (for a single outdoorunit system RX(Y)Q14-20TRY6 models).
Compressor backup operation function
13
7/24/2019 Daikin VRV Catalog 131014
16/84
ADVANCED TECHNOLOGIES ACHIEVE
LARGE CAPACITY ALL DC INVERTER COMPRESSOR IN COMPACT CASING
HIGHLY INTEGRATED HEAT EXCHANGER
Large capacity inverter compressor using high tension strength material,realise 12 HP compressor using 8 HP casing.
Small sizing coil end using concentratedwinding, reduces copper loss(winding resistance).
Improves motor efficiency in low rpmrange (improves intermediate
efficiency).
Distributed winding motor
(Current 8 HP compressor)
Concentrated winding motor
(New 12 HP compressor)
Coilend
Gives 2.4 times tensile strength
compared to conventional materialNew Material: 600 MPaConventional Material : 250 MPaIncreases compression chamber volumeby using thin spiral design.
As a result of having thinned a wall -thickness of the scroll, compressionchamber volume increase 50%
Development of highstrength material
Small type high efficiencyconcentrated winding motor
Improves performance by increasing heat exchanger area while maintaining the same installation space.
Change fin shape from fine louvre to waffle fin.Fin pitch can be reduced fin pitch from 2.0 mm to 1.4 mm, to realise unit
efficiency which increases heat exchanger area.
Realises highly integrated heat exchanger performance
(increase row, reduce fin pitch) by reducing of airflowresistance which changes cooling tube to 7.
Heat exchangerarea
Contribution of COP(cooling)
10 HP16 HP
13%UP 105.5%24%UP 111.5%
Fine Louvre Fin Waffle Fin
3 rows with small pipe design,increase heat transfer efficiency
20 HP
VRV
14
7/24/2019 Daikin VRV Catalog 131014
17/84
EXCELLENT PERFORMANCE
VARIOUS ADVANCED CONTROL MAIN PC BOARD
Computer control board SMTpackagingmaterial
*SMT: Surface mounted technology
Computer control board surface
adopting SMT packagingtechnology
Conventionalcomputer control
board surface
SMT packaging technology adopted by thewhole computer control panel improves theanti-clutter performance.
Protects your computer boards from adverseeffects of sandy and humid weather.
SMT* packaging technology
Downsizes electric component, relocates to deadspace of bell mouth side to decrease airflow resistance.
Refrigerant cooling technology, ensures stability of PCB temperature
Improves reliability at high ambient temperatureIt is possible to cool the inverter power module stability even at high ambient temperature.This helps to keep airconditioning capacity and also ensures efficient and reliable operation.
Bell mouth
Electric Component Space
VRV
Improved inner design to increase smooth airflow
15
7/24/2019 Daikin VRV Catalog 131014
18/84
OUTDOOR UNIT LINEUP
The outdoor unit capacity is up to 60 HP in increment of 2 HP.
VRVIVoutdoor unit offers a higher capacity of up to 60 HP, responding to the needs of large-sized buildings.
The single outdoor unit has only 2 different shapes and dimensions, not only simplifying the design process, but also bringing the
system flexibility to a new level.
With the outdoor unit capacity increased in increment of 2 HP, customers' needs can be precisely met.
Outdoor units with anti-corrosion specifications (-E type on request) are designed specifically for use in areas which are subject to
salt damage and atmospheric pollution.
Normal (Space Saving) Type
RX(Y)Q22TRY6RX(Y)Q24TRY6
22, 24 HP
Double Outdoor Units
RX(Y)Q6TRY6(E)RX(Y)Q8TRY6(E)RX(Y)Q10TRY6(E)RX(Y)Q12TRY6(E)
RX(Y)Q14TRY6(E)RX(Y)Q16TRY6(E)
6, 8, 10, 12 HP 14, 16 HP
RX(Y)Q18TRY6(E)RX(Y)Q20TRY6(E)
18, 20 HP
Single Outdoor Units
26, 28, 30, 32 HP
RX(Y)Q26TRY6RX(Y)Q28TRY6
RX(Y)Q30TRY6RX(Y)Q32TRY6
RX(Y)Q42TRY6RX(Y)Q44TRY6
RX(Y)Q46TRY6RX(Y)Q48TRY6RX(Y)Q50TRY6RX(Y)Q52TRY6RX(Y)Q54TRY6RX(Y)Q56TRY6RX(Y)Q58TRY6RX(Y)Q60TRY6
Triple Outdoor Units
34, 36, 38, 40 HP
Double Outdoor Units
46, 48, 50, 52, 54, 56, 58, 60 HP42, 44 HP
RX(Y)Q34TRY6RX(Y)Q36TRY6
RX(Y)Q38TRY6RX(Y)Q40TRY6
Lineup
HP
Normal (SpaceSaving) Type
OUTDOOR UNITS
16
7/24/2019 Daikin VRV Catalog 131014
19/84
INDOOR UNIT LINEUP
HEAT PUMPENHANCED RANGE OF CHOICES
FXVQ-MY1
FXVQ-MY16(high static pressure type)
A variety of VRV indoor units are enabled in one system, opening the door to stylishand quiet indoor units.
VRVindoor units
Type Model Name
15 types 79 models
FXMQ-MVE
FXFQ-SVM
17
7/24/2019 Daikin VRV Catalog 131014
20/84
INDOOR UNIT LINEUP
Ceiling Mounted Cassette(Round Flow with Sensing)Type (Optional)
Presence of people and floortemperature can be detected toprovide comfort and energy savings
FXFQ-SVM
At Daikin, we offer a wide range of indoor units, including both VRVandresidential models, responding to a variety of needs of our customers thatrequire airconditioning solutions.
Ceiling Mounted Cassette(Compact Multi Flow)Type
Quiet, compact, and designed foruser comfort
4-Way Flow CeilingSuspended Type
Ceiling Mounted Cassette(Round Flow) Type
FXFQ-LUV1
360 airflow improves temperaturedistribution and offers a comfortableliving environment.
This slim and stylish indoor unitachieves optimum air distribution,and can be installed without theneed for ceiling cavity.
Ceiling Mounted Cassette(Double Flow) Type
Thin, lightweight, and easy to installin narrow ceiling spaces
Ceiling Mounted CassetteCorner Type
Slim design for flexibleinstallation
Slim Ceiling Mounted DuctType
Slim design, quietness andstatic pressure switching
Ceiling Mounted DuctType
High external static pressureallows flexible installations
FXDQ-PBVE
FXDQ-NBVE
FXMQ-PVE
FXMQ-MAVE
FXZQ-MVE
FXCQ-MVE FXKQ-MAVE
FXUQ-AVEB
VRVIndoor Units
18
7/24/2019 Daikin VRV Catalog 131014
21/84
Floor Standing Type
Concealed Floor StandingType
Suitable for perimeter zone air conditioning
FXLQ-MAVE
FXNQ-MAVE
Ceiling Suspended Type
Slim body with quiet and wideairflow
FXHQ-MAVE
Floor Standing Duct Type
FXVQ-MY1FXVQ-MY16
Large airfiow type for large spaces.Flexible interior design for each tenant.
(high static pressure type)
Wall Mounted Type
Stylish flat panel designharmonised with your interiordcor
FXAQ-PVE
19
7/24/2019 Daikin VRV Catalog 131014
22/84
INDOOR UNIT LINEUP
VRV INDOOR UNITS
FXFQ25S / FXFQ32S / FXFQ40S
FXFQ50S / FXFQ63S / FXFQ80S
FXFQ100S / FXFQ125S
Dual sensors detect the presence of people and floor temperature
to provide comfortable air-conditioning and energy savings.
Thanks to the individual airflow direction control function, airflowdirection can be individually adjusted for each air dischargeoutlet. Five directions of airflow and auto-swing can be selectedwith wired remote controller BRC1E62, which realises optimumair distribution.
Presence of people and floor temperature can bedetected to provide comfort and energy savings
Infrared presence sensor
Ceiling Mounted Cassette (Round Flow with Sensing) Type (Optional)
Presence ofpeople in 4areas
Detecting theaveragetemperature ofindoor floor
Infrared floor sensor
Individual airflow direction control
The sensor detects the floor temperature and automaticallyadjusts operation of the indoor unit to reduce the temperaturedifference between the ceiling and the floor.
Indoor unit offers 360 airflow, discharges air in alldirections with more uniform temperature distribution.
Dead spot of airflow
Control of airflow rate can be selected from 3-stepcontrol, which provides comfortable airflow. Auto airflowrate control can be selected with wired remote controllerBRC1E62.
Low operation sound level
45/40/35
125
44/38/32
100
38/35/31
80
38/33/28
63
36/32/28
50
31/29/27
4025/32
30/28.5/27Soundlevel
(H/M/L)
FXFQ-S
Drain pump is equipped asstandard accessory with 850 mmlift.
850 mm
Energy efficiency has been improved thanks to theadoption of a new heat exchanger with smaller tubes,DC fan motor and DC drain pump motor.
The sensor detects human presence and adjuststhe airflow direction automatically to prevent drafts.Energy saving control can be performedwhen no people are detected.
Position 0 Position 2
Position 3 Swing
Individual airflow direction example case
20
7/24/2019 Daikin VRV Catalog 131014
23/84
*3
When there are no people in a room,the set temperature is shifted automatically.
If people do not return, the air conditioner will raise thetemperature 1C every 30 minutes and then operate at 30C.
Example: Cooling setpoint: 26C Shift temperature: 1.0C
Shift time: 30 min. Limit cooling temperature: 30C
Shift temperature and time can be selected from 0.5 to 4C in 0.5C incrementsand 15, 30, 45, 60, 90 or 120 minutes respectively with remote controller.
Sensing sensor stop mode
*2. User can set these functions with remote controller.
*1. These functions are not available when using the group control system.
*1. 2
When there are no people in a room, the systemstops automatically.
Absent stop time can be selected from 1 to 24 hrs in 1 hrincrements with remote controller.
Sensing sensor low mode *1. 2
New airflow block function preventsuncomfortable drafts by reducing air velocity.It can be set using the BRC1E62 remote controller.There is no need for sealing material of air dischargeoutlet (option).
This function only works when all-round flowis used. It cannot be used when sealing material isused in the air discharge outlet (option).
Total comfort by individual airflow direction controland newly-equipped airflow block function
Also can supportthis case
Airflow blockfor cabinet side
Airflow blockair velocityapprox. 0.3m/s*4
Airflow block function prevents uncomfortabledrafts by reducing air velocity to approx. 0.3m/s.*4
Airflow blockHorizontal flow
*4. In case of FXFQ63S type (Data is based on Daikin research.)
*3. Works in one direction only.
Easy setup with remote controller
500mm
Wall
Airflowblock
*5
*5. A gap of 1500 mm is required if the air block function is not used.
The airflow block function isuseful when rearranging theroom layout.
Sensing function
Auto airflow rate mode + Auto airflow direction mode
Floor temperature is detected and over cooling prevented.
Energy savings
The temperature near the person is automatically calculated bydetecting the temperature of the floor. Energy is saved, because
the area around the feet does not get too cold.
Comfortable airflowAirflow rate automatically increases during hot or cold periods (when thereis a large difference with set temperature), and operation is rapidlyperformed for cooling or heating.When the difference with set temperaturebecomes small, drafts are prevented by automatically reducing airflow rate,and raising the flap to a horizontal position during the cooling operation.
Without sensing function
With sensing function
30C near ceiling
20C near floor
Roomtemperature isdetected as
30C.
Room temperature iscalculated as 27C in the area which
is in the vicinity of the person.
30C near ceiling
24C near floor
Automaticcontrol usingthe temperaturenear the personas the roomtemperature.
The floor temperature, which is lowerthan near the ceiling, is detected.
Area around feet getstoo cold because airconditioner continuesuntil the temperaturenear the ceiling reachesthe set temperature.
Sensing sensor mode
Airflow block function
28
27
26
OccupiedUnoccupied
Automaticallyreverts whenpeople return.
27C
28C
26C26C 26C26C
27C
28C
Setpoint(C)
TimeAfter 30 min After another 30 min
21
7/24/2019 Daikin VRV Catalog 131014
24/84
INDOOR UNIT LINEUP
VRV INDOOR UNITS
360 airflow improves temperature distributionand offers a comfortable living environment.
Note: Whatever the discharge direction, the same type of panel is used. If installing for other than all-round flow, an air discharge outlet sealing material (option) must be used to close each unused outlet.
3-way flow L-shaped 2-way flowAll-round flow 4-way flow
The industrys first* Round Flow Ceiling Mounted
Cassette type offers 360airflow with improved
temperature distribution.
The light weight unit at 19.5 kg for FXFQ25-50LU
models make installation easy.
A modern sophisticated decoration panel has been
applied, with a panel surface that has been treated with
a dirt-repellant coating. An antibacterial treatment that uses silver ions has
been applied to the drain pan, preventing the growth
of slime, mould and bacteria that cause blockagesand odours.
The horizontal louvres prevent dew condensation.
Their non-flocking surfaces, which repel dirt, are
easy to clean.
The air filter has an anti-mould and antibacterial
treatment that prevents the growth of mould
generated from dust or moisture that may adhere to
the filter.
Example of airflow patterns:All-round flow is available, as well as 2-way to
4-way flows, so you can choose the most
suitable airflow pattern depending on location orroom layout.
Drain pump is equipped as a
standard accessory with a 850 mm
lift.
Treated surface Untreated surface
Resistssoiling
Condition afterexposure to thesmoke of 600cigarettes in 1 m
3
enclosed space.
Dirt andgrime
Control of the airflow rate can be selected from 3-step
control.
4-way flowRound Flow
There are areas ofuneven temperature.
There are much fewerareas of uneven temperature.
* As of April 2004, the release date for Japan.
Low operation sound level (dB(A))
44/39/34
125
43/37.5/32
100
36/33.5/31
80
34/31/28
63
32/29.5/27
50
31/29/27
4025/32
30/28.5/27Soundlevel
(HH/H/L)
FXFQ-LU
850 mm
Ceiling Mounted Cassette (Round Flow) Type
FXFQ25LU / FXFQ32LU / FXFQ40LU
FXFQ50LU / FXFQ63LU / FXFQ80LU
FXFQ100LU / FXFQ125LU
22
7/24/2019 Daikin VRV Catalog 131014
25/84
Quiet, compact, and designed for user comfort
Dimensions correspond with 600 mm X 600 mm
architectural module ceiling design specifications.
Wide discharge angle: 0 to 60
2-, 3-, and 4-way airflow patterns are available,
enabling installation in the corner of a room.
0
60
0
60
Auto swing
Fixed angles: 5 levels
*Angles can be also set on site t o prevent drafts (0-35)or soiling of the ceiling (25-60), other than standard setting (0-60).
750 mm
4-way flow 3-way flowL-shaped
2-way flow
1
2
0 0
60 60
Comfortable airflow
Drain pump is equipped as standard accessory with
750 mm lift.
*For 3-way or 2-way flow installation, the sealing member for air discharge outlet(option) must be used to close each unused outlet.
Ceiling Mounted Cassette (Compact Multi Flow) Type
FXZQ20M / FXZQ25M / FXZQ32M
FXZQ40M / FXZQ50M
Low operation sound level(dB(A))
32/2930/25
20/25 32 4040 5050
33/2932/26 36/3036/28 41/3441/33
FXZQ-M
Sound level(H/L)
Sound level(H/L)
23
7/24/2019 Daikin VRV Catalog 131014
26/84
INDOOR UNIT LINEUP
VRV INDOOR UNITS
This slim and stylish indoor unit achieves
optimum air distribution, and can be installed
without a ceiling cavity.Unit body and suction paneladopted round shapes andrealised a slim appearancedesign. The unit can be usedfor various locations such asthe ceilings with no cavity andbare ceilings.
Flaps close automatically whenthe unit stops, which gives asimple appearance.
Unified slim height of 198 mmfor all models that gives theunified impression even whenmodels with different capacitiesare installed in the same area.
Built-in electronic expansion valve eliminates the needfor a BEV unit, which improves flexibility of installation.
With adoption of the individual flap control, airflowdirection adjustment can be individually set for each airoutlet. Five directions of airflow and auto-swing can beselected with wired remote controller BRC1E62, whichrealises the optimum air distribution.
Control of the airflow rate has been improved from2-step to 3-step control. Auto airflow rate control canbe selected with wired remote controller BRC1E62.
Energy efficiency has been improved, thanks to theadoption of a new heat exchanger with smaller
tubes, DC fan motor and DC drain pump motor.
Drain pump is equipped as a standard accessory, and the
lift height has been improved from 500 mm to 600 mm.
Depending on the installation site requirements orroom conditions, 2-way, 3-way and 4-way dischargepatterns are available.
4-way flow 3-way flow
L-shaped 2-way flow
198 mm
BEV unit isnot needed
BEV unit isneeded
Current model New model
4-Way Flow Ceiling Suspended Type
Position 0 Position 2
Position 3 Swing
Individual airflow direction example case
FXUQ71A / FXUQ100A
24
7/24/2019 Daikin VRV Catalog 131014
27/84
Thin, lightweight, and easy to install innarrow ceiling spaces
305 mm
The thin unit (only 305 mm high) can be installed in a
ceiling space as narrow as 350 mm. All models feature a
compact design with a depth of only 600 mm.
(When a high-efficiency filter is attached, the unit's height is400 mm.)
Designed with higher airflow suitable for high ceil ing
application up to 3 metres.
Providing 2 different settings of standard and ceiling soiling
prevention, the auto swing mechanism realises even
distribution of airflow and room temperature.
Two types of optional high-efficiency filters are available
(65% and 95%, colourimetric method).
A long-life filter is equipped as a standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
Major maintenance work can be performed by removing
the panel. A flat-type suction grille and a detachable
blade make cleaning easy.
Ceiling Mounted Cassette (Double Flow) Type
FXCQ20M / FXCQ25M / FXCQ32M
FXCQ40M / FXCQ50M / FXCQ63M
FXCQ80M / FXCQ125M
Drain pump is equipped as standard accessory with
600 mm lift.
600 mm
(220 V)(dB(A))Low operation sound level
FXCQ-M 20
32/27
25/32
34/28
63
37/32
40/50
34/29
80
39/34
125
44/38Sound level
(H/L)
25
7/24/2019 Daikin VRV Catalog 131014
28/84
INDOOR UNIT LINEUP
VRV INDOOR UNITS
Ceiling Mounted Cassette Corner Type
Slim design for flexible installation
Main body
Air discharge grille(Option)
Set for front discharge using a suspended ceiling.
Downward discharge is shut off and air is blown straight out
(front discharge).
Front discharge is possible with an air
discharge unit (option), which allows the
installation in the drop-ceiling or sagging wall.
Single-flow type allows effective air discharge
from corner or from drop-ceiling.
Providing 3 different settings of standard, draft
prevention and ceiling soiling prevention, the
auto swing mechanism assures even
distribution of airflow and room temperature.
Main body
Downward discharge
Air discharge grille (Option)
3
32C 30C
28C 26C24C
22C
20C
2
1
0 1 2 3 4 5 6 (m)
(m)
500 mm
Drain pump is equipped as standard
accessory with 500 mm lift.
Panel spacer20 mm
Min.195 mm
Slim body needs only 220 mm space above the
ceiling. If you use a panel spacer (option), the
unit can be installed in the minimum space of
195 mm.
A long-life filteris equipped as a standard
accessory.
* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
FXKQ25MA / FXKQ32MA
FXKQ40MA / FXKQ63MA
26
7/24/2019 Daikin VRV Catalog 131014
29/84
Slim design, quietness andstatic pressure switching
Only 200 mm in height, this model can be installed in
rooms with as little as 240 mm depth between the
drop-ceiling and ceiling slab.
Only 700 mm in width and 23 kg in weight, this
model is suitable for installation in limited
spaces like drop-ceilings in hotels.
* The values of operation sound level represent those for rear-suction operation.Sound level values for bottom-suction operation can be obtained by adding 5 dB(A).
* Values are based on the following conditions:
FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure
of 15 Pa.
* 1,100 mm in width for the FXDQ63NB model.
200 mm900mm
Suction grille *AIR
AIR
Discharge grille *
Air filterSuspension bolt*
240mm
* To be obtained locally
Only700mm200mm
Great for
hotel use!
Suited to use in drop-ceilings!
750 mm
Ceiling
Control of the airflow rate has been improved from 2-step
to 3-step control.
Slim Ceiling Mounted Duct Type
FXDQ20PB / FXDQ25PB / FXDQ32PB FXDQ40NB / FXDQ50NB / FXDQ63NB
Low operation sound level (dB(A))
36/34/3236/34/32
6363
35/33/31
50
34/32/30
40
33/31/29
20/25/32
Sound level(HH/H/L)
FXDQ-PB/NB
External static pressure selectable by remote controllerswitching make this indoor unit a very comfortable andflexible model.
10 Pa-30 Pa/factory set: 10 Pa for FXDQ-PB models.15 Pa-44 Pa/factory set: 15 Pa for FXDQ-NB models.
FXDQ-PB and FXDQ-NB models are available with adrain pump as a standard accessory.
FXDQ-PB/NBVE: with a drain pump (750 mm lift)as a standard accessory
27
7/24/2019 Daikin VRV Catalog 131014
30/84
INDOOR UNIT LINEUP
VRV INDOOR UNITS
Ceiling Mounted Duct Type
Middle and high static pressureallows for flexible duct design
All models are only 300 mm in height, animprovement over the 390 mm height ofconventional models. The weight of theFXMQ40P has been reduced from 44 kg to 28 kg.
A DC fan motor increases the external staticpressure capacity range to include middle to highstatic pressures, increasing design flexibility.
Simplified Static Pressure ControlExternal static pressure can be easily adjusted usinga change-over switch inside the electrical box to meetthe resistance in the duct system.
FXMQ200MA/FXMQ250MA
Drain pump is equipped asstandard accessory with700 mm lift.
Control of the airflow rate has been improvedfrom 2-step to 3-step control.
(dB(A))
46/45/43
140
42/40/38
63
43/41/39
80/100
41/39/37
50
39/37/35
40
34/32/30
32
33/31/29
20/25
Soundlevel
(HH/H/L)
FXMQ-P
700 mm
Ceiling
30 Pa100 Pa for FXMQ20P-32P30 Pa160 Pa for FXMQ40P
50 Pa200 Pa for FXMQ50P-125P50 Pa140 Pa for FXMQ140P
Low operation sound level
Improved ease of installation
Improved ease of maintenance
Airflow rate can be controlled using a remote controller during
test operations. With the conventional model, the airflow rate
was controlled from the PC board. It is automatically adjusted to
the range between approximately 10% of the rated HH tap
airflow for FXMQ20P125P.
The drain pan can be detached for easy cleaning. An
antibacterial treatment that uses silver ions has been applied to
the drain pan, preventing the growth of slime, mould and
bacteria that cause blockages and odours.
Energy-efficient
The adopted DC fan motor is much more efficient than
the conventional AC motor, yielding an approximate
20% decrease in energy consumption (FXMQ125P).
44/42/40
125
FXMQ20P / FXMQ25P / FXMQ32P
FXMQ40P / FXMQ50P / FXMQ63P
FXMQ80P / FXMQ100P / FXMQ125P
FXMQ140P
28
7/24/2019 Daikin VRV Catalog 131014
31/84
Slim body with quiet and wide airflow
Adoption of QUIET STREAM FAN
Drain pump kit (option) can be easily incorporated.
Easy-to-clean flat design
Maintenance is easier because everything can be
performed from below the unit.
Non-dew flap with no implanted bristles
Uses the quiet stream fan and manymore advanced technologies.
Sound absorptionmember
Turbulent flowis produced
Straightening vane
Quiet stream fan
Installation is easy
Maintenance is easy
Drain pump kit(built inside main unit)
600mm
Bristle-free flap minimisescontamination and makescleaning simpler.
Non-dew Flap
100
Wide air discharge openings produce a spreading 100
airflow.
A long-life filter is equipped as standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
Ceiling Suspended Type
FXHQ32MA / FXHQ63MA
FXHQ100MA
FXHQ-MA
Sound level(H/L)
Sound level(H/L)
3232
36/3136/31
6363
39/3439/34
100100
45/3745/37
(dB(A))Low operation sound level
29
7/24/2019 Daikin VRV Catalog 131014
32/84
INDOOR UNIT LINEUP
VRV INDOOR UNITS
Stylish flat panel design harmonised
with your interior dcor
Drain pan and air filter can be kept clean by mould-proof
polystyrene.
Vertical auto-swing realises efficiency of air distribution.
The louvre closes automatically when the unit stops.
5 steps of discharge angle can be set by remotecontroller.
Discharge angle is automatically set at the same angle
as the previous operation when restarting. (Initial setting:
10 for cooling and 70 for heating)
Flexible installation
Drain pipe can be fitted to it from either left or
right sides.
Stylish flat panel design creates a graceful harmony that
enhances any interior space.
Flat panel can be cleaned with only the single pass of a
cloth across their smooth surface.
Flat panel can also be easily removed and washed for
more thorough cleaning.
Wall Mounted Type
Drain pump kit is available as optional accessory, which
lifts the drain 1,000 mm from the bottom of the unit.
Drain pump kit
1,000 mm
Height of drain-up
Indoor unit
FXAQ20P / FXAQ25P
FXAQ32P / FXAQ40P
FXAQ50P / FXAQ63P
Low operation sound level(dB(A))
47/4147/41
6363
42/3742/37
5050
39/3439/34
4040
38/3138/31
3232
36/3136/31
2525
35/3135/31
2020
Sound level(H/L)
Sound level(H/L)
FXAQ-PFXAQ-P
30
7/24/2019 Daikin VRV Catalog 131014
33/84
Suitable for perimeter zone airconditioning
Wall hanging Floor installation
Floor Standing types can be hung on the wall for easier
cleaning. Running the piping from the back allows the
unit to be hung on walls. Cleaning under the unit, where
dust tends to accumulate, is considerably easier.
A long-life filter is equipped as standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
The adoption of a fibre-less discharge grille, featuring an
original design to prevent condensation, also helps
prevent staining and makes cleaning easier.
Designed to be concealed in the perimeter skirting-wall
Connectingport
Refrigerantpiping
* Applies also to Floor Standing type (FXLQ-MA).
The unit is concealed in the skirting-wall of the perimeter,
that creates a classy interior design.
The connecting port faces downwards,
greatly facilitating on-site piping work.
A long-life filter is equipped as a
standard accessory.* 8 hr/day, 25 day/month. For dust concentration of 0.15 mg/m3
Floor Standing Type
Concealed Floor Standing Type
FXNQ20MA / FXNQ25MA
FXNQ32MA / FXNQ40MA
FXNQ50MA / FXNQ63MA
FXLQ20MA / FXLQ25MA
FXLQ32MA / FXLQ40MA
FXLQ50MA / FXLQ63MA
31
7/24/2019 Daikin VRV Catalog 131014
34/84
INDOOR UNIT LINEUP
VRV INDOOR UNITS
FXVQ125M / FXVQ200M
FXVQ250M / FXVQ400M
FXVQ500MY16
Floor Standing Duct Type
Large airflow type for large spaces.Flexible interior design for each customer.
Large airflow type that fits for spacious areas such as factoriesand large stores.
Various installations can be supported from full-scale ductconnection airflow to direct airflow that allows for easyinstallation.
The high static pressure type driven by the belt drivesystem allows for use of air discharge outlets in variousshapes as well as long ducts. Highly flexible installationis possible.
High maintainability design that allows major servicesand maintenance services to be performed at the front.
A long-life filter is equipped as a standard accessory.* 8 hr/day, 26 day/month. For dust concentration of 0.15 mg/m3
A wide range of optional accessories are available suchas high-efficiency filters.
Outdoor air intake mode isuseable as an outdoor-airprocessing airconditioner.
*When using the unit as an outdoor-airprocessing unit, there are somerestrictions.
All-fresh (using outdoor air only) system Return + Outdoor air mixed system
OutsideAirconditioning
Outdoor airintroduction
Airconditioning
Circulatedair
Outdoor airintroduction
Outside
* Air introduced from the outside and circulated air must be mixed in theair conditioner primary side before introduction into the air conditioner.
Adding the plenum chamber (option)allows for simple operation with directairflow.* Note that the operation sound increases by
approximately 5 dB(A).
Direct airflow type
Full-scale duct connection airflowallows for airconditioning evenly inspacious areas.
Duct connection airflow type32
7/24/2019 Daikin VRV Catalog 131014
35/84
7/24/2019 Daikin VRV Catalog 131014
36/84
SPECIFICATIONS
VRV INDOOR UNITS
Ceiling Mounted Cassette (Round Flow) Type
1-phase, 220-240 V, 50 Hz
2,400
9,600
2.8
2,800
10,900
3.2
3,100
12,300
3.6
3,400
13,600
4.0
3,900
15,400
4.5
4,300
17,100
5.0
4,800
19,100
5.6
5,400
21,500
6.3
13/11.5/10
459/406/353
30/28.5/27
15/13/11
530/459/388
31/29/27
16/13.5/11
565/477/388
32/29.5/27
FXFQ25LUV1 FXFQ32LUV1 FXFQ40LUV1 FXFQ50LUV1
Galvanised steel plate
6,100 7,700 9,600 12,000
24,200 30,700 38,200 47,800
7.1 9.0 11.2 14.0
6,900
27,300
8.0
8,600
34,100
10.0
10,800
42,700
12.5
13,800
54,600
16.0
19/16.5/13.5
671/583/477
34/31/28
32/26/20
1,130/918/706
43/37.5/32
33/28/22.5
1,165/989/794
44/39/34
21/18/15
742/636/530
36/33.5/31
FXFQ63LUV1 FXFQ80LUV1 FXFQ100LUV1 FXFQ125LUV1
9.5
15.9
VP25 (External Dia, 32/Internal Dia, 25)
BYCP125K-W1
Fresh white
50X950X950
5.5
6.4
12.7
13/11.5/10
459/406/353
30/28.5/27
cfm
dB(A)
mm
kg
mm
mm
kg
m3/min
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Model
Colour
Dimensions(HWD)
Weight
Casing
Sound level (HH/H/L)
Dimensions (HWD)
Machine weight
Pipingconnections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
Airflow rate (HH/H/L)
22 25
246X840X840 288X840X840
19.5
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Ceiling Mounted Cassette (Round Flow with Sensing) Type (Optional)
Fresh white
50950950
5.5
19
246840840 288840840
Galvanised steel plate
1-phase, 220- 240 V, 50 Hz
441/406/353
30/28.5/27
12.5/11.5/10.0
2.8
2,800
10,900
3.2
9,600
2,400
FXFQ25SVM
441/406/353
30/28.5/27
12.5/11.5/10.0
3.6
3,400
13,600
4.0
12,300
3,100
FXFQ32SVM
512/459/388
31/29/27
14.5/13.0/11.0
4.5
4,300
17,100
5.0
15,400
3,900
FXFQ40SVM
23
777/618/477
36/32/28
22.0/17.5/13.5
5.6
5,400
21,500
6.3
19,100
4,800
FXFQ50SVM
BYCQ125B-W1
6.4
12.7
I.D. 25O.D. 32(VP25)
15.9
9.5
7.1
6,900
27,300
8.0
24,200
6,100
FXFQ63SVM
830/653/477
38/33/28
23.5/18.5/13.5
11.2
10,800
42,700
12.5
38,200
9,600
FXFQ100SVM
1,165/918/671
44/38/32
33.0/26.0/19.0
9.0
8,600
34,100
10.0
30,700
7,700
FXFQ80SVM
830/688/530
38/35/31
23.5/19.5/15.0
14.0
13,800
54,600
16.0
47,800
12,000
FXFQ125SVM
1,218/971/741
45/40/35
34.5/27.5/21.0
26
cfm
dB(A)
mm
kg
mm
mm
kg
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Model
Colour
Dimensions(HWD)
Weight
Casing
m3/min
Sound level (H/M/L)
Airflow rate (H/M/L)
Dimensions (HWD)
Machine weight
Pipingconnections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
34
7/24/2019 Daikin VRV Catalog 131014
37/84
Ceiling Mounted Cassette (Compact Multi-Flow) Type
4-way Flow Ceiling Suspended Type
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.
1-phase, 220-240 V/220 V, 50 Hz
1,900
7,500
2.2
2,200
8,500
2.5
2,400
9,600
2.8
2,800
10,900
3.2
3,100
12,300
3.6
3,400
13,600
4.0
3,900
15,400
4.5
4,300
17,100
5.0
4,800
19,100
5.6
5,400
21,500
6.3
Galvanised steel plate
9/7 9.5/7.5 11/8 14/10
318/247 335/265 388/282 493/353
30/25 32/26 36/28 41/33
286575575
18
6.4
12.7
VP20 (External Dia, 26/Internal Dia, 20)
BYFQ60B8W1
White (6.5Y9.5/0.5)
55700700
2.7
FXZQ20MVE FXZQ25MVE FXZQ32MVE FXZQ50MVEFXZQ40MVE
1-phase, 220-240 V/220-230 V, 50 Hz
6,900 9,600
27,300 38,200
8.0
7,700
30,700
9.0
11.2
10,800
42,700
12.5Fresh white
22.5/19.5/16 31/26/21
794/688/565 1,094/918/741
40/38/36 47/44/40
198950950
26 27
9.5
15.9
VP20 (External Dia, 26/Internal Dia, 20)
FXUQ71AVEB FXUQ100AVEB
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
cfm
dB(A)
mm
kg
mm
mm
kg
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Model
Colour
Dimensions(HWD)
Weight
Casing
Dimensions (HWD)
Machine weight
Pipingconnections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
cfm
dB(A)
mm
kg
mm
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Casing
Sound level (H/M/L)
Dimensions (HWD)
Machine weight
Pipingconnections
Power supply
Heating capacity
Cooling capacity
m3/min
MODEL
Airflow rate (H/L)
Airflow rate (H/M/L)
Sound level (H/L) 230 V
m3/min
35
7/24/2019 Daikin VRV Catalog 131014
38/84
SPECIFICATIONS
VRV INDOOR UNITS
Ceiling Mounted Cassette (Double Flow) Type
Ceiling Mounted Cassette Corner Type
FXCQ20MVE FXCQ25MVE FXCQ32MVE FXCQ40MVE FXCQ50MVE FXCQ63MVE FXCQ80MVE FXCQ125MVE
1-phase, 220-240 V/220 V, 50 Hz
1,900 2,400 3,100 3,900 4,800 6,100 7,700 12,000
7,500 9,600 12,300 15,400 19,100 24,200 30,700 47,800
2.2 2.8 3.6 4.5 5.6 7.1 9.0 14.0
2,200
8,500
2.5
2,800
10,900
3.2
3,400
13,600
4.0
4,300
17,100
5.0
5,400
21,500
6.3
6,900
27,300
8.0
8,600
34,100
10.0
13,800
54,600
16.0
Galvanised steel plate
7/5 9/6.5 9/6.5 12/9 12/9 16.5/13 26/21 33/25
247/177 318/230 318/230 424/318 424/318 582/459 918/741 1,165/883
32/27 34/28 34/28 34/29 34/29 37/32 39/34 44/38
305775600 305775600 305775600 305990600 305990600 3051,175600 3051,665600 3051,665600
26.0 26.0 26.0 31.0 32.0 35.0 47.0 48.0
6.4 6.4 6.4 6.4 6.4 9.5 9.5 9.5
12.7 12.7 12.7 12.7 12.7 15.9 15.9 15.9
VP25 (External Dia, 32/Internal Dia, 25)
BYBC32G-W1 BYBC50G-W1 BYBC63G-W1 BYBC125G-W1
White (10Y9/0.5)
531,030680 531,030680 531,030680 531,245680 531,245680 531,430680 531,920680 531,920680
8.0 8.0 8.0 8.5 8.5 9.5 12.0 12.0
FXKQ25MAVE
9,600
2,400
Galvanised steel plate
11/9
FXKQ32MAVE
12,300
3,100
FXKQ40MAVE
15,400
3,900
FXKQ63MAVE
2.8 3.6 4.5 7.1
24,200
6,100
11/9 13/10 18/15
388/318 388/318 459/353 635/530
215X1,110X710
31
6.4
12.7
VP25 (External Dia, 32/Internal Dia, 25)
BYK45FJW1
White (10Y9/0.5)
70X1,240X800
8.5
215X1,110X710
31
6.4
12.7
70X1,240X800
8.5
215X1,110X710
31
6.4
12.7
70X1,240X800
8.5
215X1,310X710
34
9.5
15.9
BYK71FJW1
70X1,440X800
9.5
38/33 38/33 40/34 42/37
1-phase, 220-240 V/220 V, 50 Hz
Note: Specifications are based on the following conditions;Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.Sound level: (FXCQ-M) Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.
(FXKQ-MA) Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.During actual operation, these values are normally somewhat higher as a result of ambient conditions.
2,800
10,900
3.2
3,400
13,600
4.0
4,300
17,100
5.0
6,900
27,300
8.0
cfm
dB(A)
mm
kg
mm
mm
kg
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Model
Colour
Dimensions(HWD)
Weight
Casing
m3/min
Sound level (H/L)
Dimensions (HWD)
Machine weight
Pipingconnections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
cfm
mm
kg
mm
mm
kg
kcal/h
Btu/h
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Model
Colour
Dimensions(HWD)
Weight
Casing
m3/min
Sound level (H/L)
Dimensions (HWD)
Machine weight
Pipingconnections
Panel(Option)
Power supply
Heating capacity
Cooling capacity
MODEL
kW
220 V dB(A)
Airflow rate (H/L)
Airflow rate (HH/M/L)
220 V
36
7/24/2019 Daikin VRV Catalog 131014
39/84
Slim Ceiling Mounted Duct Type (700 mm width type)
Slim Ceiling Mounted Duct Type (900/1,100 mm width type)
FXDQ20PBVE FXDQ25PBVE FXDQ32PBVE
FXDQ40NBVE FXDQ50NBVE FXDQ63NBVE
1-phase, 220-240 V/220 V, 50 Hz
1,900
7,500
2.2
2,200
8,500
2.5
2,400 3,100
12,300
3.6
3,400
13,600
4.0
9,600
2.8
2,800
10,900
3.2
Galvanised steel plate
8.0/7.2/6.4 8.0/7.2/6.4 8.0/7.2/6.4
282/254/226 282/254/226 282/254/226
30-10
33/31/29 33/31/29 33/31/29
200700620 200700620 200700620
23.0 23.0 23.0
6.4 6.4 6.4
12.7 12.7 12.7
VP20 (External Dia, 26/Internal Dia, 20)
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0m.Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
1-phase, 220-240 V/220 V, 50 Hz
3,900 4,800 6,100
15,400 19,100 24,200
4.5
4,300
17,100
5.0
5.6
5,400
21,500
6.3
7.1
6,900
27,300
8.0
Galvanised steel plate
10.5/9.5/8.5 12.5/11.0/10.0 16.5/14.5/13.0371/335/300 441/388/353 583/512/459
44-15
34/32/30 35/33/31 36/34/32
200900620 200900620 2001,100620
27.0 28.0 31.0
6.4 6.4 6.4
12.7 12.7 12.7
VP20 (External Dia, 26/Internal Dia, 20)
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.
1:Values are based on the following conditions: FXDQ-PB: external static pressure of 10 Pa; FXDQ-NB: external static pressure of 15 Pa.2:External static pressure is changeable to set by the remote controller. This pressure means "High static pressure - Standard". (Factory setting is
10 Pa for FXDQ-PB models and 15 Pa for FXDQ-NB models.)3: The values of operation sound level represent those for rear-suction operation. Sound level values for bottom-suction operation can be
obtained by adding 5 dB(A).
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
cfm
Pa
dB(A)
mm
kg
mm
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Casing
m3/min
Dimensions (HWD)
Machine weight
Pipingconnections
Power supply
Heating capacity
Cooling capacity
MODELwith drain pump
External static pressure
Sound level (HH/H/L)
cfm
Pa
dB(A)
mm
kg
mm
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Casing
m3
/min
Dimensions (HWD)
Machine weight
Pipingconnections
Power supply
Heating capacity
Cooling capacity
MODELwith drain pump
External static pressure
Sound level (HH/H/L)
Airflow rate (HH/H/L)
Airflow rate (HH/H/L)
1 3
1 3
2
2
37
7/24/2019 Daikin VRV Catalog 131014
40/84
SPECIFICATIONS
VRV INDOOR UNITS
Ceiling Mounted Duct Type
Note: Specifications are based on the following conditions;
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m. Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
Sound level: Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.During actual operation, these values are normally somewhat higher as a result of ambient conditions.
1: Power consumption values are based on conditions of rated external static pressure.
2: External static pressure can be modified using a remote controller that offers seven (FXMQ20-32P), thirteen (FXMQ40P), fourteen (FXMQ50-125P) or ten (FXMQ140P) levels of control. These values indicate the lowest and highest possible static pressures. The standard staticpressure is 50 Pa for FXMQ20-32P and 100 Pa for FXMQ40-140P.
15,400
3,900
565/459/388
19,100
4,800
635/582/530
4.5 5.6
6.4
12.7
6.4
12.7
16/13/11 18/16.5/15
7,500
1,900
318/265/230
2.2
6.4
12.7
9/7.5/6.5
9,600
2,400
318/265/230
2.8
6.4
12.7
9/7.5/6.5
12,300
3,100
335/282/247
3.6
6.4
12.7
9.5/8/7
VP25 (External Dia, 32/Internal Dia, 25)
24,200
6,100
688/618/565
9.5
15.9
30,700
7,700
883/794/706
9.5
15.9
38,200
9,600
1,130/953/812
9.5
15.9
47,800
12,000
1,377/1,165/988
9.5
15.9
7.1 9.0 11.2 14.0
19.5/17.5/16 25/22.5/20 32/27/23 39/33/28
42/40/38 43/41/39 43/41/39 44/42/40
54,600
13,800
1,624/1,377/1,130
9.5
15.9
16.0
46/39/32
46/45/43
FXMQ20PVE FXMQ25PVE FXMQ32PVE FXMQ40PVE FXMQ50PVE
2,200
8,500
2.5
6,900
27,300
8.0
8,600
34,100
10.0
10,800
42,700
12.5
13,800
54,600
16.0
15,500
61,400
18.0
2,800
10,900
3.2
3,400
13,600
4.0
4,300
17,100
5.0
5,400
21,500
6.3
300X1,000X700300X700X700300X550X700300X550X700300X550X700
3628252525
41/39/3739/37/3534/32/3033/31/2933/31/29
cfm
Pa
dB(A)
mm
kg
mm
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Casing
m3/min
Dimensions (HWD)
Machine weight
Pipingconnections
Power supply
Heating capacity
Cooling capacity
MODEL
External static pressure
Sound level (HH/H/L)
cfm
Pa
dB(A)
mm
kg
mm
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Casing
m3/min
Dimensions (HWD)
Machine weight
Pipingconnections
Power supply
Heating capacity
Cooling capacity
MODEL FXMQ63PVE FXMQ80PVE FXMQ100PVE
1-phase, 220-240 V/220 V, 50 Hz
Galvanised steel plate
300X1,400X700
46
300X1,000X700
36
300X1,000X700
36
300X1,400X700
46
300X1,400X700
47
FXMQ125PVE FXMQ140PVE
External static pressure
Sound level (HH/H/L)
Airflow rate (HH/H/L)
Airflow rate (HH/H/L)
230-100 (50) 230-100 (50) 230-100 (50) 230-160 (100) 250-200 (100)
250-200 (100)250-200 (100)250-200 (100)250-200 (100) 250-140 (100)
1-phase, 220-240 V/220 V, 50 Hz
Galvanised steel plate
VP25 (External Dia, 32/Internal Dia, 25)
38
7/24/2019 Daikin VRV Catalog 131014
41/84
FXHQ32MAVE FXHQ63MAVE FXHQ100MAVE
1-phase, 220-240 V/220 V, 50 Hz
3,100 6,100 9,600
12,300 24,200 38,200
3.6 7.1 11.2
3,400
13,600
4.0
6,900
27,300
8.0
10,800
42,700
12.5
White (10Y9/0.5)
12/10 17.5/14 25/19.5
424/353 618/494 883/688
36/31 39/34 45/37
195960680 1951,160680 1951,400680
24.0 28.0 33.0
VP20 (External Dia, 26/Internal Dia, 20)
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
FXMQ200MVE FXMQ200MVE
76,400
19,300
22.4 28.0
95,500
24,100
1-phase, 220-240 V/220 V, 50 Hz
Galvanised steel plate
58/50
2,047/1,765
470X1,380X1,100
137
9.5
19.1
PS1B
72/62
2,542/2,189
470X1,380X1,100
137
9.5
22.2
132-221 191-2702 2
48/45 48/45
Sound level:(FXMQ-MA)Anechoic chamber conversion value, measured at a point 1.5 m downward from the unit centre.(FXHQ-MA)Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.
During actual operation, these values are normally somewhat higher as a result of ambient conditions 1: Power consumption values are based on conditions of standard external static pressure.
2: External static pressure is changeable to change over the connectors inside electrical box, this pressure means "Standard-High static pressure".
21,500
85,30025.0
27,100
107,50031.5
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
cfm
Pa
mm
kg
mm
kcal/h
Btu/h
kW
kcal/h
Btu/hkW
Liquid (Flare)
Gas (Flare)
Drain
Casing
m3/min
Dimensions (HWD)
Machine weight
Pipingconnections
Power supply
Heating capacity
Cooling capacity
MODEL
External static pressure
Sound level(H/L)
cfm
dB(A)
mm
kg
mm
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Casing
m3/min
Dimensions (HWD)
Machine weight
Pipingconnections
Power supply
Heating capacity
Cooling capacity
MODEL
Sound level (H/L)
220 V dB(A)
Airflow rate (H/L)
Airflow rate (H/L)
Ceiling Mounted Duct Type
Ceiling Suspended Type
6.4
12.7 15.9 15.9
9.5 9.5
39
7/24/2019 Daikin VRV Catalog 131014
42/84
SPECIFICATIONS
VRV INDOOR UNITS
Wall Mounted Type
Floor Standing Type/Concealed Floor Standing Type
FXLQ
FXNQ
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.
Sound level: (FXAQ-P)Anechoic chamber conversion value, measured at a point 1 m in front of the unit and 1 m downward.(FXLQ-MA, FXNQ-MA)Anechoic chamber conversion value, measured at a point 1.5 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
FXAQ20PVE FXAQ25PVE FXAQ32PVE FXAQ40PVE FXAQ50PVE FXAQ63PVE
1-phase, 220-240 V/220 V, 50 Hz
1,900 2,400 3,100 3,900 4,800 6,100
7,500 9,600 12,300 15,400 19,100 24,200
2.2 2.8 3.6 4.5 5.6 7.1
2,200
8,500
2.5
2,800
10,900
3.2
3,400
13,600
4.0
4,300
17,100
5.0
5,400
21,500
6.3
6,900
27,300
8.0
2,200
8,500
2.5
2,800
10,900
3.2
3,400
13,600
4.0
4,300
17,100
5.0
5,400
21,500
6.3
6,900
27,300
8.0
White (3.0Y8.5/0.5)
7.5/4.5 8/5 8.5/5.5 12/9 15/12 19/14
265/159 282/177 300/194 424/318 530/424 671/494
35/31 36/31 38/31 42/3739/34 47/41
290795238 290795238 290795238 2901,050238 2901,050238 2901,050238
11.0 11.0 11.0 14.0 14.0 14.0
6.4 6.4 6.4 6.4 6.4 9.5
12.7 12.7 12.7 12.7 12.7 15.9
VP13 (External Dia, 18/Internal Dia, 13)
FXLQ50MAVE
FXNQ50MAVE
FXLQ40MAVE
FXNQ40MAVE
FXLQ32MAVE
FXNQ32MAVE
FXLQ25MAVE
FXNQ25MAVE
FXLQ20MAVE
FXNQ20MAVE
FXLQ63MAVE
FXNQ63MAVE
1-phase, 220-240 V/220 V, 50 Hz
1,900 2,400 3,100 3,900 4,800 6,100
7,500 9,600 12,300 15,400 19,100 24,200
2.2 2.8 3.6 4.5 5.6 7.1
FXLQ: Ivory white (5Y7.5/1)/FXNQ: Galvanised steel plate
7/6 7/6 8/6 11/8.5 14/11 16/12
247/212 247/212 282/212 388/300 494/388 565/424
35/32 35/32 35/32 38/33 39/34 40/35
6001,000222 6001,000222 6001,140222 6001,140222 6001,420222 6001,420222
610930220 610930220 6101,070220 6101,070220 6101,350220 6101,350220
25.0 25.0 30.0 30.0 36.0 36.0
19.0 19.0 23.0 23.0 27.0 27.0
6.4 6.4 6.4 6.4 6.4 9.5
12.7 12.7 12.7 12.7 12.7 15.9
21O.D.
cfm
dB(A)
mm
kg
mm
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Casing
m3/min
Dimensions (HWD)
Machine weight
Pipingconnections
Power supply
Heating capacity
Cooling capacity
MODEL
Sound level (H/L)
Casing
Power supply
Heating capacity
Cooling capacity
MODEL
Airflow rate (H/L)
cfm
dB(A)
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid (Flare)
Gas (Flare)
Drain
Machine weight
Pipingconnections
Sound level (H/L)
Dimensions(HWD)
FXLQ
220 V
FXNQ
FXLQ
FXNQ
mm
kg
mm
Airflow rate (H/L)m3/min
40
7/24/2019 Daikin VRV Catalog 131014
43/84
Rp1 (PS 1B internal thread)
Long-life filter (anti-mould resin net)
Belt drive system
3-phase 4-wire system, 380415 V, 50 Hz
Ivory white (5Y7.5/1)
FXVQ125MY1
1,670750510
115
52
15.9 (Brazing)
FXVQ250MY1 FXVQ400MY1
1,9001,4707201,9001,170720
225
64
12.7 (Brazing)
28.6 (Brazing)
FXVQ200MY1
12,000
47,800
14.0
13,800
54,600
16.0
19,300
76,400
22.4
21,500
85,300
25.0
24,100
95,500
28.0
27,100
107,500
31.5
38,700
154,000
45.0
43,000
171,000
48,200
191,000
50.0
1,6701,170510
165
59
22.2 (Brazing)
1,670950510
140
55
9.5 (Brazing)
19.1 (Brazing)
5.5
172
6,072
FXVQ500MY16
56.0
54,200
215,000
63.0
15.9 (Brazing)
28.6 (Brazing)
0.75
43
1,518
1.5
69
2,436
1.5
86
3,036
3.7
134
4,730
480150 210 270 380
295
67
Notes: Specifications are based on the following conditions;Cooling : Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB.Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.Capacity of indoor unit is only for reference. Actual capacity of indoor unit is based on the total capacity index.*1 Sound level : measured when the air discharge outlet duct (2 m) is attached (anechoic chamber conversion value).
It increases by approximately 5 dB(A) when the plenum chamber is installed to deliver direct airflow.*2 The value is the external static pressure with standard pulley.
mm
kg
dB(A)
mm
mm
mm
kW
m3/min
cfm
Pa
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
Liquid
Gas
Drain
Type
Motor output
Airflow rate
External static pressure *2
Drive system
Casing colour
Sound level *1
Dimensions (HWD)
Machine weight
Pipingconnections
Power supply
Heating capacity
Cooling capacity
MODEL
Air filter
Fan
Floor Standing Duct Type
41
7/24/2019 Daikin VRV Catalog 131014
44/84
OUTDOOR UNITS
SPECIFICATIONS
RXYQ6TRY6(E)RXYQ8TRY6(E) RXYQ10TRY6(E) RYXQ12TRY6(E) RXYQ14TRY6(E) RXYQ16TRY6(E)
13,800
54,600
16.0
15,500
61,400
18.0
19,300
76,400
22.4
21,500
85,300
25.0
24,100
95,500
28.0
27,100
107,000
31.5
28,800
114,000
33.5
32,300
128,000
37.5
34,400
136,000
40.0
38,700
154,000
45.0
38,700
154,000
45.0
43,000
171,000
50.0
185
55
5.9
185
56
5.9
195
57
6.0
195
59
6.3
285
60
10.3
285
61
10.4
1 1 1 1
119 157 165 178 233 233
2 2
Normal (Space Saving) Type
1,657X930X765 1,657X930X765 1,657X930X765 1,657X930X765 1,657X1,240X7651,657X1,240X765
3-phase 4-wire system, 380415 V, 50 Hz
Hermetically Sealed Scroll Type
12.7(Brazing)
19.1(Brazing)
9.5(Brazing)
22.2(Brazing)
28.6(Brazing)
-5 to 49-20 to 15.5
R-410A
Note: Specifications are based on the following conditions;
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Ivory white (5Y7.5/1)
MODEL
Power supply
Capacity control % 20-100 20-100 16-100 15-100 11-100 10-100
Compressor
Dimensions (HWD)
Machine weight
Sound level
Refrigerant
Pipingconnections
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
kg
dB(A)
CDB
CWB
kg
m/min
mm
Charge
Type
Type
Liquid
Gas
mm
mm
Combination units
Cooling capacity
Heating capacity
No. of
compressor
Airow rate
Operationrange
Cooling
Heating
Casing colour
42
7/24/2019 Daikin VRV Catalog 131014
45/84
HEAT PUMP
Normal (Space Saving) Type
RXYQ10TRY6(E)
RXYQ12TRY6(E)
RXYQ12TRY6(E)
RXYQ12TRY6(E)
RXYQ18TRY6(E) RXYQ20TRY6(E) RXYQ22TRY6(E) RXYQ24TRY6(E)
233
43,000
171,000
50.0
48,200
191,000
56.0
1,657X1,240X765 1,657X1,240X765
300
62
11.7
48,200
191,000
56.0
54,200
215,000
63.0
320
65
11.8
268
52,900
210,000
61.5
59,300
235,000
69.0
(1,657X930X765)+
(1,657X930X765)
195+195
61
6.0+6.3
165+178
57,600
229,000
67.0
64,500
256,000
75.0
(1,657X930X765)+
(1,657X930X765)
195+195
62
6.3+6.3
178+178
22 22
15.9(Brazing)
28.6(Brazing)
15.9(Brazing)
28.6(Brazing)
15.9(Brazing)
28.6(Brazing)
15.9(Brazing)
34.9(Brazing)
3-phase 4-wire system, 380415 V, 50 Hz
Hermetically Sealed Scroll Type
-5 to 49
-20 to 15.5
R-410A
Note: Specifications are based on the following conditions;
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.
During actual operation, these values are normally somewhat higher as a result of ambient conditions.
Ivory white (5Y7.5/1)
MODEL
Power supply
Capacity control % 10-100 8-100 8-100 8-100
Compressor
Dimensions (HWD)
Machine weight
Sound level
Refrigerant
Pipingconnections
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
kg
dB(A)
CDB
CWB
kg
m/min
mm
Charge
Type
Type
Liquid mm
Gas mm
Combination units
Cooling capacity
Heating capacity
Airow rate
Operationrange
Cooling
Heating
Casing colour
No. of
compressor
43
7/24/2019 Daikin VRV Catalog 131014
46/84
OUTDOOR UNITS
Normal (Space Saving) Type
62,300
247,000
72.4
69,700
276,000
81.0
67,500
268,000
78.5
75,300
299,000
87.5
71,800
285,000
83.5
80,400
319,000
93.5
77,000
305,000
89.5
86,900
345,000
101
81,700
324,000
95.0
91,200
362,000
106
86,000
341,000
100
96,300
382,000
112
RXYQ12TRY6(E)
RXYQ16TRY6(E)
RXYQ8TRY6(E)
RXYQ18TRY6(E)
RXYQ28TRY6(E) RXYQ30TRY6(E)RXYQ32TRY6(E) RXYQ34TRY6(E) RXYQ36TRY6(E)RXYQ26TRY6(E)
(1,657X930X765)+
(1,657X1,240X765)(1,657X930X765)+
(1,657X1,240X765)(1,657X930X765)+
(1,657X1,240X765)(1,657X930X765)+
(1,657X1,240X765)(1,657X1,240X765)+
(1,657X1,240X765)
(1,657X1,240X765)+
(1,657X1,240X765)
185+300
63
5.9+11.7
195+285
63
6.3+10.4
195+300
64
6.3+11.7
195+320
66
6.3+11.8
285+300
65
10.4+11.7
300+300
65
11.7+11.7
RXYQ12TRY6(E)
RXYQ18TRY6(E)
RXYQ12TRY6(E)
RXYQ20TRY6(E)
RXYQ16TRY6(E)
RXYQ18TRY6(E)
RXYQ18TRY6(E)
RXYQ18TRY6(E)
157+233 178+233 178+233 178+268 233+233 233+233
43333 4
Note: Specifications are based on the following conditions;
Cooling: Indoor temp.: 27CDB, 19CWB, Outdoor temp.: 35CDB, Equivalent piping length: 7.5 m, Level difference: 0 m.Heating: Indoor temp.: 20CDB, Outdoor temp.: 7CDB, 6CWB, Equivalent piping length: 7.5 m, Level difference: 0 m.
Sound level: Anechoic chamber conversion value, measured at a point 1 m in front of the unit at a height of 1.5 m.During actual operation, these values are normally somewhat higher as a result of ambient conditions.
19.1(Brazing)
34.9(Brazing)
19.1(Brazing)
34.9(Brazing)
19.1(Brazing)
34.9(Brazing)
19.1(Brazing)
34.9(Brazing)
19.1(Brazing)
34.9(Brazing)
19.1(Brazing)
41.3(Brazing)
3-phase 4-wire system, 380415 V, 50 Hz
Hermetically Sealed Scroll Type
-5 to 49
-20 to 15.5
R-410A
Ivory white (5Y7.5/1)
MODEL
Power supply
Capacity control % 7-100 6-100 6-100 5-100 5-100 5-100
Compressor
Dimensions (HWD)
Machine weight
Sound level
Refrigerant
Pipingconnections
kcal/h
Btu/h
kW
kcal/h
Btu/h
kW
kg
dB(A)
CDB
CWB
kg
m/min
mm
Charge
Type
Type
Liquid mm
Gas mm
Combination units
Cooling capacity
Heating capacity
No. of
compressor
Airow rate
Operationrange
Cooling
Heating
Casing colour
SPECIFICATIONS
44
7/24/2019 Daikin VRV Catalog 131014
47/84
HEAT PUMP
RXYQ20TRY6(E)
RXYQ20TRY6(E)
RXYQ12TRY6(E)
RXYQ12TRY6(E)
RXYQ18TRY6(E)
RXYQ12TRY6(E)
RXYQ12TRY6(E)
RXYQ20TRY6(E)
RXYQ12TRY6(E)
RXYQ16TRY6(E)
RXYQ18TRY6(E)
RXYQ12TRY6(E)
RXYQ18TRY6(E)
RXYQ18TRY6(E)
RXYQ12TRY6(E)
RXYQ18TRY6(E)
RXYQ20TRY6(E)
RXYQ18TRY6(E)
RXYQ20TRY6(E)
RXYQ38TRY6(E) RXYQ40TRY6(E) RXYQ42TRY6(E) RXYQ44TRY6(E) RXYQ46TRY6(E) RXYQ48TRY6(E) RXYQ50TRY6(E)
233+268
91,200
362,000
106
102,000
406,000
119
(1,657X1,240X765)+
(1,657X1,240X765)
(1,657X1,240X765)+
(1,657X1,240X765)
300+320
67