24
www.davinci-ls.com “WELCOME” Da Vinci Laboratory Solutions New DVLS³ Simply, Smart, Sensor focus on Hydrogen”

Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

www.davinci-ls.com

“WELCOME”

Da Vinci Laboratory Solutions “New DVLS³ Simply, Smart, Sensor

focus on Hydrogen”

Page 2: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

www.davinci-ls.com

A Hydrogen Sensor can ensure Safety when using Hydrogen as a Carrier Gas

in a Chromatographic Systems

Da Vinci Laboratory Solutions

January 22, 2013

2

Page 3: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Talking Points

Four reasons for using H2 as a carrier gas

Safety measures

Hydrogen sensor

Principle of operation and measurement

Hardware overview

Calibration and maintenance

Benefits

Questions

Page 4: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

1. Fast Analysis:

Viscosity of H2

Low oven temp programming

2. High Efficiency:

H2 Flattest Van Deemter curve

Reasons for using H2 as a Carrier Gas

Page 5: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

3. Prolonged Column Life:

□ Due to lower oven temp

4. Cost effective:

□ 3x’s less expensive than its helium equivalent

□ Bottle or generator

Reasons for using H2 as a Carrier Gas

Page 6: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Reluctant to use H2 as a Carrier Gas?

Hydrogen is an Explosive Gas: Undetected gas leaks can lead to an explosion in the GC oven

LEL of hydrogen in Air is at 4%

Page 7: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Safety measures

Monitor hydrogen usage

Safety measures in GC hardware □ Safety Shutdown:

□ Flow Limiting Frit EPC

□ Explosion Test: GC designed to contain parts in case of explosion

6890exp.avi.MPG

Hydrogen sensor in the oven or valve box

Budget for new GC

Page 8: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Principle of Operation Hydrogen Sensor

Pellister, catalytic reaction

Surface of the pellet and noble metal will react

Exothermal oxidation of flammable gases

2 H2 + O2 → 2 H2O(g) + heat

Temperature rise

Page 9: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Principle of Measurement Hydrogen Sensor

Compensator pellet is identical but without

catalyst

Measurement circuit: a Wheatstone Bridge

9 28 March 2013

Page 10: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Gas sensitivity Hydrogen Sensor

1% H2 = 80 mV

Page 11: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Accuracy of the Hydrogen Sensor

Room temperature bandwith

Page 12: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Typical long term zero offset drift Hydrogen Sensor

Page 13: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Hardware overview for a Hydrogen Sensor for GC applications

Page 14: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Sensor installed in the GC Oven

Transfertube through the oven wall to ensure a stable temperature

Page 15: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Automatic Switch to Nitrogen

After 1% H2 detection, the carrier gas supply is switched to nitrogen. The system will maintain a flow through the column.

Page 16: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

After 1% H2 detection, the sequence will stop after the analysis. No waste of analyses or sample.

Automatic Stop Signal to GC

Page 17: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

After 1% H2 detection a choice of alarm signals:

17

Alarm messages

Acoustic alarm

Optical alarm (blinking display)

SMS alarm message

Page 18: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

4 Sensors, one controller

Page 19: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

www.davinci-ls.com

H2

Pressure Temp

Leak detection

(Optional) Text message alarm if out of range

Switch to N2 as carrier gas

19

Page 20: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Calibration & Maintenance

Zero Point Calibrated Using Air

Alarm level Calibrated using Calibration Mixture

Yearly or after maintenance or repair

A Silicon hose can’t be used

Page 21: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

Benefits

Able to use 4 different or 4 same sensors on one

unit

Battery operated in case of leak detection

Power failure, battery back-up (few hours)

Multiple alarms

Can link LIMS system to log alarms

In future be able to talk by Wifi

High sensitivity and long life time

Page 22: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

www.davinci-ls.com

Questions?

Page 23: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

www.davinci-ls.com

Contact Details

[email protected] www.davinci-ls.com P: +31 (0)10 258 1870 F: +31 (0)10 258 1879

23

Page 24: Da Vinci Laboratory Solutions - Grupo Biomaster · Da Vinci Laboratory Solutions January 22, 2013 2 . Talking Points Four reasons for using H 2 ... stable temperature. Automatic Switch

www.davinci-ls.com

THANK YOU!

24