D SERIES DIAPHRAGM PUMPS ASM PUMPS 14 Nicole Way, Dandenong South, Victoria, 3175 Ph: 03 9793 7577 Email: [email protected] www.asmpumps.com.au D SERIES PULSATION DAMPENERS Dimenions & specificaons are subject to change without noce. This document cannot be reproduced, in whole or in part without wrien consent from ASM PUMPS For opmum performance of ASM D Series Diaphragm Pumps a Pulsaon Dampener should be fied to both Sucon & Discharge sides of the pump. The Pulsaon Dampener helps reduce the variaons in flow & pressure produced by the single acng diaphragm pump. It reduces water hammer, vibraon and noise whilst maximising pump efficiency & service life. Discharge: The PD1D & PD2D are an air filled vessel installed in the discharge pipe work as close to the pump discharge port as possible. The air is separated from the fluid by a flexible diaphragm. The dampener stores up and discharges part of the stroke volume by compressing and expanding in sync with the pump. It absorbs a poron of the pump displacement stores it momentarily before discharging during the sucon stroke. Sucon The PD1S & PD2S are a vessel installed in the sucon pipe work as close to the pump sucon port as possible. During the sucon stroke of the pump the diaphragm must overcome the inera of the fluid in the sucon pipework. At the end of the stroke the inera must again be overcome to bring the fluid to rest. This constant acceleraon and deceleraon cycle causes pressure pulsaons which may lead to water hammer, vibraon and noise. During the sucon stroke a vacuum is created behind the flexible diaphragm. This allows the dampener to absorb and store momentarily a poron of the sucon line fluid during the discharge stroke of the pump Materials of Construcon Diaphragm: Nitrile Opons: EPDM & Viton Casngs: Aluminium Opons: Bronze & Stainless Selecon Chart Pump Size: Sucon: Discharge: D25 , D32 PD1S PD1D D38, D50 & D76 PD2S PD2D Typical Installaon DT50 with PD2S and PD2D shown Sucon Discharge Diaphragm Orientaon PD1D & PD2D PD1S & PD2S PD1S & PD1D Port Size: 32NB BSP Female PD2S & PD2D Port Size: 50NB BSP Female

D Series Pulsation Dampener - ASM Pumps...D SERIES DIAPHRAGM PUMPS ASM PUMPS 14 Nicole Way, Dandenong South, Victoria, 3175 Ph: 03 9793 7577 Email: [email protected] D SERIES PULSATION

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

D SERIES DIAPHRAGM PUMPS

ASM PUMPS14 Nicole Way, Dandenong South, Victoria, 3175Ph: 03 9793 7577 Email: [email protected]

D SERIES PULSATION DAMPENERS

Dimenions & specifications are subject to change without notice. This document cannot be reproduced, in whole or in part without written consent from ASM PUMPS

For optimum performance of ASM D Series Diaphragm Pumps a Pulsation Dampener should be fitted to both Suction & Discharge sides of the pump. The Pulsation Dampener helps reduce the variations in flow & pressure produced by the single acting diaphragm pump. It reduces water hammer, vibration and noise whilst maximising pump efficiency & service life.

Discharge:The PD1D & PD2D are an air filled vessel installed in the discharge pipe work as close to the pump discharge port as possible. The air is separated from the fluid by a flexible diaphragm. The dampener stores up and discharges part of the stroke volume by compressing and expanding in sync with the pump. It absorbs a portion of the pump displacement stores it momentarily before discharging during the suction stroke.

SuctionThe PD1S & PD2S are a vessel installed in the suction pipe work as close to the pump suction port as possible.During the suction stroke of the pump the diaphragm must overcome the inertia of the fluid in the suction pipework. At the end of the stroke the inertia must again be overcome to bring the fluid to rest. This constant acceleration and deceleration cycle causes pressure pulsations which may lead to water hammer, vibration and noise. During the suction stroke a vacuum is created behind the flexible diaphragm. This allows the dampener to absorb and store momentarily a portion of the suction line fluid during the discharge stroke of the pump

Materials of Construction Diaphragm: Nitrile Options: EPDM & VitonCastings: Aluminium Options: Bronze & Stainless

Selection Chart Pump Size: Suction: Discharge: D25 , D32 PD1S PD1D D38, D50 & D76 PD2S PD2D

Typical Installation

DT50 with PD2S and PD2D shown

Suction Discharge

Diaphragm Orientation

PD1D & PD2D

PD1S & PD2S

PD1S & PD1DPort Size: 32NB BSP Female