Customizable solutions for contact lines – flexible under all contact lines – flexible under all
requirements at high speedAlbrecht BRODKORB
CTO Rail Electrification, Siemens AG, Germany
� July 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
Content
1. Functional approach for contact line designs
2. Classified, universal solutions for overhead contact lines
3. Adaptions for functional changes
Albrecht BrodkorbCTO Rail Electrification, Siemens AG, GermanyJuly 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
2
3. Adaptions for functional changes
4. Customization for special requests
Function of contact lines
Transmission of electric energy
� from substation
Valid for different requirements
� Environmental conditions
Albrecht BrodkorbCTO Rail Electrification, Siemens AG, GermanyJuly 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
3
The contact line has no redundancy !!
� to the running train
- for the required energy quality
- for save operation
- without interruptions
- without influences to other systems and components
� Operation rules
� Lifetime expectations
� Maintenance procedures
Element Classification for Overhead Contact Lines
Wiring ( Catenary, Feeders, Conductors)
• safe and secure operation
• wear of contact wire and collector strip
• current capacity ( catenary and additional wires )
���� important for the running speed and train operation
Switching and Insulation
• Sectioning
Albrecht BrodkorbCTO Rail Electrification, Siemens AG, GermanyJuly 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
4
• Sectioning
���� Electrical usability and equipment operation
Structures
• mechanical safety
• lifetime
• maintenance work
���� Integration in existing systems for outer functions arbitrary
Resume for High speed lines:
High speed operation needs achievements for the catenary according interaction with pantograph and electrical capability
Siemens Contact Line System - Sicat ® HA
Sicat H – main parameters:
contact wire RiM 120 27 kN
messenger wire Bz II 120 21 kN
limit of cw-wear 20 %
current capacity 840 A (40 K by current flow)
max train speed 350 km/h multiple pantographs
Overlaps
insulated 5 span
uninsulated 3 spans
Albrecht BrodkorbCTO Rail Electrification, Siemens AG, GermanyJuly 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
5
uninsulated 3 spans
Sicat HA is in operation at high speed lines for 30 0 km/h and more:
Cologne - Frankfurt ( Germany )La Sagra - Toledo ( Spain )Segovia -Valladolid ( Spain )HSL Zuid ( Netherlands )Beijing - Tianjin ( China )
Sicat HA – Applications
HSL Zuid (Netherlands)
Cologne – Rhine/Main (Germany)
Albrecht BrodkorbCTO Rail Electrification, Siemens AG, GermanyJuly 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
6
La Sagra –Toledo (Spain)Segovia – Valladolid (Spain)
Beijing – Tianjin (China)
Sicat ® – Siemens Contact Line Systems
v < 120 km/h
v > 230 km/h
v < 230 km/h
Tram
v < 160 km/h
Main lineAC
Main lineDC
Mass transitDC
Sicat HASicat SASicat SX
Sicat LA Sicat SD
Sicat HD
Sicat LLD
Catenaries for classified functional requirements
Sicat LD
Albrecht BrodkorbCTO Rail Electrification, Siemens AG, GermanyJuly 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
7
Arrangements and components are usable for all cont act lines under the special circumstances
Sets of arrangements for all elements Based on tested and approved components
Application for different conditions
Internal properties� Localization of elements
� Architectural requests
� Installation procedures
� Integration in existing systems
� Combination with local designs
Functional changes� Train- pantograph configuration
� Speed requirements
� Environmental conditions
� Power demand
� Mixed operation
Albrecht BrodkorbCTO Rail Electrification, Siemens AG, GermanyJuly 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
8
System adaption���� Change of wiring / Catenary
Customizing����Changes of arrangements
and/or elements
HSL Zuid (Netherlands)
System adaption - Beijing -Tianjin Line
C o n t a c t F o rc e P a n t o g ra p h 1
1 0 0
2 0 0
3 0 0
4 0 0
Fo
rce
[N
]
Use of stitch wire achieves same interaction behavior for:
• increased speed of around 25% or
• around 20% increased span length*
* when not limited by other parameters like panhead geometry
70 m span length with stitch wire
Cologne - Frankfort (Germany)
Albrecht BrodkorbCTO Rail Electrification, Siemens AG, GermanyJuly 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
9
Sicat HA for Beijing-Tianjin Line
- Line nearly complete at viaduct
- Maximum span length reduced to 50 m
- Design without stitch wire sufficient for 300km/h 50 m span length without stitch wire
0
5 6 0 6 0 0 6 4 0 6 8 0 7 2 0 7 6 0 8 0 0 8 4 0
L o c a tio n o f P a n to g r a p h [ m ]
U p lif t o f t h e C o n t a c t W ire P a n t o g ra p h 1
- 2 5
0
2 5
5 0
7 5
5 6 0 6 0 0 6 4 0 6 8 0 7 2 0 7 6 0 8 0 0 8 4 0
L o c a tio n o f P a n to g r a p h [ m ]
Up
lift
[m
m]
70 m span length with stitch wire
Customizing – Adjustability of cantilevers
System functionality is equivalent with all designs- Free and unrestricted Uplift >200 mm- Material ( e.g. corrosion free aluminum)- Aluminum design
Sicat cantilevers with different adjustability
Albrecht BrodkorbCTO Rail Electrification, Siemens AG, GermanyJuly 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
10
Adjustability linked with:
- Compatibility with existing systems- Installation conditions and rules
Customizing with local designs for refurbishments
Sicat elements:
- Wiring (catenary, contact wire, droppers )
- Elements under voltage level and insulators
- Tensioning equipment
Local design :
- Foundations
- Poles, portal structures
- Earthing equipment
Albrecht BrodkorbCTO Rail Electrification, Siemens AG, GermanyJuly 12, 2012, Session: Infrastructure 3 – Power supply and Signalling
11
- Earthing equipment
- Current return elements
Benefit ����
- Proven and tested design for functional parts
- Corrosion free elements at voltage level
- Usable with local poles, foundations and portals
- Interfaces adaptable to local designs ( e.g. insulator cap )
- Compatible with existing solutions
...Thank you...Thank youfor your kind attention