Olympus NDT Canada 505, boul. du Parc-Technologique Tel. : (418) 872-1155 Québec (Québec) G1P 4S9 Fax. : (418) 872-5431 Canada Web site : www.olympusndt.com EDDY CURRENT: ECT EXTENDED ASME CALIBRATION TUBE RECOMMENDED CALIBRATION TUBES The CT02 ECT calibration tube below provides every defect that is required to perform a good ECT calibration and build strong phase-to-depth curves. In fact, this tube is not only conforming to the ASME standards. In addition, it also provides wall thinning defects in order to help users to perform a more accurate calibration. ARTIFICIAL DEFECT PARAMETERS IN FUNCTION OF TUBE WT AND OD Defect Depth (%WT) Diameter Defect Depth (%WT) Diameter GR10 10 % (internal) - H80 80 % 0.078” GR20 20 % - H60 60% 0.125” GR40 40 % - H40 40% 0.188” GR60 60 % - H20 20% 0.188” (4 holes) H100a Thru If OD>0.75”, 0.067” Else: 0.052” H100b Thru If OD>0.75”, 0.125” Else: 0.078” VARIABLE CHART IN FUNCTION OF TUBE OD Variable Value Variable Value Variable Value in mm in mm in mm A 1.25” 32mm D 3.00” 76mm TL 20.50” 521mm B 1.50” 38mm GLa 1/16” 1.6mm SP_OD OD + 3/4" OD + 19mm C 3.50” 89mm GLb 1/2" 13mm SP_TCK 3/8” 10mm GR10 GR20 H100a H80 H60 H40 H20 H100b GR40 GR60 SP01-XXX GR10 (internal) GR20 H100a H80 H60 H40 H20 H100b GR40 GR60 DIFF (pits) ABS (wall thinning)

Ct02 Ect Extended Asme

Embed Size (px)

DESCRIPTION

ECT standard reference

Citation preview

Page 1: Ct02 Ect Extended Asme

Olympus NDT Canada 505, boul. du Parc-Technologique Tel. : (418) 872-1155 Québec (Québec) G1P 4S9 Fax. : (418) 872-5431 Canada Web site : www.olympusndt.com

EDDY CURRENT: ECT EXTENDED ASME CALIBRATION TUBE

RECOMMENDED CALIBRATION TUBES

The CT02 ECT calibration tube below provides every defect that is required to perform a good ECT calibration and build strong phase-to-depth curves. In fact, this tube is not only conforming to the ASME standards. In addition, it also provides wall thinning defects in order to help users to perform a more accurate calibration.

ARTIFICIAL DEFECT PARAMETERS IN FUNCTION OF TUBE WT AND OD

Defect Depth (%WT) Diameter Defect Depth (%WT) Diameter

GR10 10 % (internal) - H80 80 % 0.078”

GR20 20 % - H60 60% 0.125”

GR40 40 % - H40 40% 0.188”

GR60 60 % - H20 20% 0.188” (4 holes)

H100a Thru If OD>0.75”, 0.067” Else: 0.052”

H100b Thru If OD>0.75”, 0.125” Else: 0.078”

VARIABLE CHART IN FUNCTION OF TUBE OD

Variable Value

Variable Value

Variable Value

in mm in mm in mm

A 1.25” 32mm D 3.00” 76mm TL 20.50” 521mm

B 1.50” 38mm GLa 1/16” 1.6mm SP_OD OD + 3/4" OD + 19mm

C 3.50” 89mm GLb 1/2" 13mm SP_TCK 3/8” 10mm

GR10 GR20 H100a H80 H60 H40 H20 H100b GR40 GR60

SP01-XXX

GR10

(internal) GR20 H100a H80 H60 H40 H20 H100b GR40 GR60

DIFF (pits)

ABS (wall thinning)